Industrial Trading chervon right Manufacturers chervon right G chervon right GENERAL ELECTRIC chervon right ASTAT
About product Datasheet FAQ

GENERAL ELECTRIC ASTAT

Description

General Electric ASTAT Series Digital Soft Starters | for 3ph Standard Induction Motors

Part Number

ASTAT

Price

Request Quote

Manufacturer

GENERAL ELECTRIC

Lead Time

Request Quote

Category

Digital Soft Starter

Datasheet

pdf file

General_Electric_ASTAT_Series_Soft_Starters_datasheet1-605968808.pdf

2879 KiB

Extracted Text

GE Industrial Solutions ASTAT Soft starters for 3ph standard induction motors High reliability for multiple applications GE imagination at work Small soft starters ASTAT S Small soft starters with integral bypass ASTAT S is compact, easy to operate soft starter, designed for use with standard 3-phase squirrel cage motors. It provides an advanced method of reducing current during motor starting and stopping. ASTAT S will start supplying a reduced voltage to the motor, increasing up to the rated voltage, so avoiding, high currents and generating soft starting and stopping. The motor has to be able to start in a reduced voltage. • Solid soft starter for standard 3ph AC motors up to 30kW at 400V AC • Voltage ratings up to 600V • Two phase control with integral bypass • Compact, small case • DIN rail mounting. Optional from 31A • Start and soft stop features Approvals/Marking Technical data Ratings Voltage ratings 3ph AC systems 220/230V (+10%, -15%) for units QA02P_ _ _ S cULus 380/415V (+10%, -15%) for units QA12P _ _ _ S 480/500V (+10%, -15%) for units QA22P _ _ _ S The cUL, is achieved for all range of ASTAT S, 575/600V (+10%, -15%) for units QA32P _ _ _ S except for 58A models, items QA02P058S, Frequency range 50/60Hz (±5%) QA12P058S, QA22P058S, QA32P058S. Load 3ph, AC standard motors Control specifi cations Ramp up 0.5 - 10 s (set by potentiometer) Ramp down 0.5 - 10 s (set by potentiometer) Initial voltage 0 - 80% Un (set by potentiometer) Starting torque 0 - 64% Tn I/O control Inputs one input for Start/Stop Outputs one output for «End of Ramp» signal for ratings 31, 44, 58A Ambient conditions Operating temperature 0 to 40ºC. Up to 60ºC derating by 1.2% per ºC Storage temperature -20 to 70ºC Relative humidity up to 80%, without condensation Max. altitude up to 1000m. Above this derate by 5% each 100m Protection degree IP20 1 ASTAT S Small soft starters with integral bypass Input Current Maximum Maximum mot or power (1) Cat. No. Ref. no. Pack voltage rating (2) current 220/230V 380/415V 480/500V 575/600V VAC A A kW / HP kW / HP kW / HP kW / HP 220 8 28 1.5 / 2 - - - QA02P008S 120881 1 17 60 4 / 5.5 - - - QA02P017S 120882 1 22 77 5.5 / 7.5 - - - QA02P022S 120883 1 31 110 7.5 / 10 - - - QA02P031S 120884 1 44 150 11 / 15 - - - QA02P044S 120885 1 58 200 15 / 20 - - - QA02P058S 120886 1 400 8 28 - 4 / 5.5 - - QA12P008S 120892 1 17 60 - 7.5 / 10 - - QA12P017S 120893 1 22 77 - 11 / 15 - - QA12P022S 120894 1 31 110 - 15 / 20 - - QA12P031S 120895 1 44 150 - 22 / 30 - - QA12P044S 120896 1 58 200 - 30 / 40 - - QA12P058S 120897 1 500 8 28 - - 5.5 / 7.5 - QA22P008S 120898 1 17 60 - - 11 / 15 - QA22P017S 120899 1 22 77 - - 15 / 20 - QA22P022S 120900 1 31 110 - - 22 / 30 - QA22P031S 120901 1 44 150 - - 30 / 40 - QA22P044S 120902 1 58 200 - - 45 / 60 - QA22P058S 120903 1 600 8 28 - - - 7.5 / 10 QA32P008S 120904 1 17 60 - - - 15 / 20 QA32P017S 120905 1 22 77 - - - 22 / 30 QA32P022S 120906 1 31 110 - - - 30 / 40 QA32P031S 120907 1 44 150 - - - 37 / 50 QA32P044S 120908 1 58 200 - - - 55 / 75 QA32P058S 120909 1 Accessory DIN rail mounting kit for types 31A, 44A and 58A QAOPTDIN 120910 1 (1) Ratings for standard 4-poles AC motors (2) See Operations/hour in table below Cycles/hour includes both soft start and soft stop Time between rampings Start/Stop Starting Ramp 1 sec. Ramp 2 sec. Ramp 5 sec. Ramp 10 sec. current (A) QA_2P008S 8 7 15 35 70 16 16 33 77 155 24 26 51 125 250 28 (*) 32 62 155 - QA_2P017S 17 7 15 35 70 34 16 33 77 155 51 26 51 125 250 60 (*) 32 62 155 - QA_2P022S 22 7 15 35 70 44 16 33 77 155 66 26 51 125 250 77 (*) 32 62 155 - QA_2P031S 31 4 8 20 40 62 8 15 38 76 93 12 24 62 124 110 (*) 15 31 80 - QA_2P044S 44 4 8 20 40 88 8 15 38 76 132 12 24 62 124 155(*) 15 31 80 - QA_2P058S 58 4 8 20 40 116 8 15 38 76 174 12 24 62 124 200 (*) 15 31 80 - (*) Maximum starting current at all 2 Digital soft starters Small soft starters ASTAT S Diagrams Control by push-buttons, Control by permanent command line contactor and thermal overload (soft start and stop) relay (soft start) start/stop Control by push-buttons and line Forward/reverse control by (3) contactor (soft start) push-buttons Motor power ASTAT S Q1 Q2 KM1 Q3 F1-F2 S1-S2-S3 380/415V Thermal kW Hp Am fuses Contactor overload relay 4 5.5 QA12P008 GPS1B*AK 10 EC25A 268103 - P9 7.5 10 QA12P017 GPS1B*AN 25 EC25A 268105 - P9 11 15 QA12P022 GPS1B*AP 32 EC25A 268106 - P9 15 20 QA12P031 GPS1B*AR 40 EC32A 268108 - P9 22 30 QA12P044 GPS2B*AT 63 CL06A 113722 - P9 30 40 QA12P058 GPS2B*AU 80 CL07A 113723 - P9 Coordination type 2, with thermal overload relays, class 10. For other thermal class, please consult our Controls & Power Electronics catalogue. (1) Use dry contact only. (2) End of Ramp output relay (only types 31A, 44A and 58A). (3) Forward/Reverse operation must be done when motor is not rotating. (4) Ground terminal only for types 31A, 44A and 58A. 3 ASTAT S Performances Direct-on-line start ASTAT S soft start DOL Uo=0.5Un, To=25Tn, RAMP UP 0.9s Time Time Direct-on-line stop ASTAT S soft stop DOL RAMP DOWN 0.5s Time Time 4 Digital soft starters Speed Speed Speed Speed Voltage Voltage Voltage Voltage Current Current Current Current Small soft starters ASTAT S Dimensional drawings Small soft starter with integral bypass TYPE Weight (kg) TYPE Weight (kg) QA12P008S 0.470 QA_2P017S 0.610 QA_2P022S 0.650 QA22P008S 0.470 QA32P008S 0.650 Dimensions in mm Dimensions in mm TYPE Weight (kg) QA_2P031S 1.370 QA_2P044S 1.400 QA_2P058S 1.400 2 2 Dimensions in mm 5 ASTAT Notes .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... 6 Soft starters Digital soft starters ASTAT XT ASTAT XT Digital sof D t starters for 3ph standard induction mot in ors GE´s new AST G AT XT solid state soft starter features microprocessor control digital technology. Setup and adjustment is per d formed through a six-button k keypad and parameters or messages ar e e displayed out trough a friendly L LCD multilanguage inter C face with two rows, sixteen alphanumeric characters each. The design includes isolated I/O and high lev ea el of protection in their cir ci cuits to minimize the disturbance effects while working in the hardest industrial envir in onment. AST A AT XT soft starter offers reliable performance and smooth acceleration for a v fo ariety of standard AC motors up to 1400A and up to 690V, reducing mechanical shock to the driving system, r m esulting in extended component and motor life. a AST A AT XT offers many traditional features such a motor overload function, adjustable ramps, current limit, kick start, but also other high end features like Inside-Delta operation, Torque control, Pump control and a reliable motor Approvals / Marking and unit set of protections. Key features For units up to 820A. “U” type • Ratings up to 1400Amps and up to 690VAC • Friendly multilanguage interface with two rows, sixteen characters each • Built-in with three extra power terminals for external bypass • In-Line or Inside-Delta operation modes • Torque control and pump control advanced features • Motor protection according IEC 10, 20 and NEMA 10, 20, 30, even if Control panel ASTAT XT is in bypass • Built-in communications RS485 port, and ModBus protocol as standard • Profi busDP and DeviceNet optional interfaces for communications 7 ASTAT XT Recommended motor and type unit ratings Built-in communication network International version L Light Duty ight Duty N Normal Duty (IEC Class 10) ormal Duty (IEC Class 10) H Heavy Duty eavy Duty Modbus Profi bus DP DeviceNet Modbus Profi bus DP DeviceNet Max rating Rated 230V 400V-415V 480V-500V 690V Rated 230V 400V-415V 480V-500V 690V current (A) current (A) kW kW kW kW current (A) kW kW kW kW Mains voltage 8 8 1.5 3 4 - 8 1.5 3 4 - 230-500Vac 17 17 4 7.5 7.5 - 12 3 5.5 5.5 - Control voltage 34 31 7.5 15 18.5 - 31 7.5 15 18.5 - 230Vac 54 44 11 22 30 - 44 11 22 30 - 65 58 15 30 37 - 55 15 30 37 - 72 72 22 37 45 - 66 18.5 37 45 - 104 85 22 45 55 - 80 22 45 55 - Digital inputs 130 105 30 55 55 - 99 30 55 55 - 156 145 45 75 90 - 130 37 55 90 - voltage 90-230Vac 170 170 55 90 110 - 134 37 75 90 - 248 210 55 110 132 - 203 55 110 132 - 361 310 90 160 200 - 310 75 160 200 - 390 390 110 200 250 - 344 110 160 250 - 480 460 132 250 315 - 432 132 250 315 - 480 460 132 250 315 - 432 132 250 315 - 610 580 160 315 400 - 488 160 250 355 - 610 580 160 315 400 - 552 160 315 400 - 820 650 200 355 400 - 552 160 315 400 - 820 820 250 400 560 - 690 200 400 500 - 1180 950 315 560 630 - 950 315 560 630 - 1375 1100 355 630 800 - 1076 355 630 800 - 1750 1400 400 800 1000 - 1400 400 800 1000 - 8 8 --- 5.5 8 --- 5.5 Mains voltage 690Vac 17 17 - - - 15 12 - - - 7.5 Control voltage 34 31 - - - 22 31 - - - 22 230Vac 54 44 - - - 37 44 - - - 37 65 58 - - - 55 55 - - - 45 72 72 - - - 55 66 - - - 55 104 85 - - - 75 80 - - - 75 Digital inputs 130 105 - - - 90 99 - - - 90 voltage 156 145 - - - 132 130 - - - 90 90-230Vac 170 170 - - - 160 134 - - - 132 248 210 - - - 200 203 - - - 200 361 310 - - - 250 310 - - - 250 390 390 - - - 355 344 - - - 315 480 460 - - - 400 432 - - - 400 610 580 - - - 560 488 - - - 400 820 650 - - - 630 552 - - - 560 1180 950 - - - 900 950 - - - 900 1375 1100 - - - 1000 1076 - - - 1000 1750 1400 ---- 1400 ---- Remarks page 8 - Motor kW ratings given in above table are for IEC, standard AC four poles motors. - Always check that motor rated current is less than the specifi ed rated current of the starter, for the specifi c application (Normal Duty or Heavy Duty) - Other control and digital inputs voltages are available. Please contact GE - Profi bus or DeviceNet options cannot be ordered separately. For those communication networks, please order the ASTAT XT with the required option built-in remarks page 9 - Motor HP ratings given in NEMA table are for standard AC four poles motors. - Always check that motor rated current is less than the specifi ed rated current of the starter, for the specifi c application (Light Duty, Normal Duty or Heavy Duty) - Remote mounting kit for keypad that includes cable (3m), remote keypad box, dummy cover, frame and brackets: - Frame A QTAKPADKIT1 169072 - Frame B and others QTAKPADKIT2 169073 For the international version: - Frame A QTAKPADKIT1SG 129052 - Frame B and others QTAKPADKIT2SG 129053 QT10008U21MS QT10105U21MS QT10460N21MS ASTAT XT 8A-72A ASTAT XT 105A-170A ASTAT XT 460A-650A 8 Digital soft starters Order codes ASTAT XT B Built uilt-in communication netw -in communication netwo ork rk I Int nte ernational v rnational ve er rsion sion Light Duty Normal Duty (IEC Class 10) Heavy Duty M Modbus odbus P Pr ro ofi fi bus bus D DP P D DeviceNet eviceNet M Modbus odbus P Pr rofi ofi bus bus DP DP D DeviceNet eviceNet QT___N21PS QT___N21DS QT___N21PSG QT___N21DSG QT___U21PS QT___U21DS QT___U21PSG QT___U21DSG Cat. No. Ref. No. Ref. No. Ref. No. Cat. No. Ref. No. Ref. No. Ref. No. QT10008U21MS 169075 169214 169314 QT10008U21MSG 129213 120954 817850 QT10017U21MS 169076 169215 169315 QT10017U21MSG 129214 120957 817851 QT10031U21MS 169077 169216 169316 QT10031U21MSG 129215 120958 817852 QT10044U21MS 169078 169217 169317 QT10044U21MSG 129216 120959 817853 QT10058U21MS 169079 169218 169318 QT10058U21MSG 129217 120960 817854 QT10072U21MS 169080 169219 169319 QT10072U21MSG 129218 120961 817855 QT10085U21MS 169081 169220 169320 QT10085U21MSG 129219 120962 817856 QT10105U21MS 169082 169221 169321 QT10105U21MSG 129220 120963 817857 QT10145U21MS QT10145U21MSG 169083 169222 169322 129221 120964 817858 QT10170U21MS 169084 169223 169323 QT10170U21MSG 129222 120965 817859 QT10210U21MS 169085 169224 169324 QT10210U21MSG 129223 120966 817860 QT10310U21MS 169086 169225 169325 QT10310U21MSG 129224 120967 817861 QT10390U21MS 169087 169226 169326 QT10390U21MSG 129225 120968 817862 QT10460N21MS QT10460N21MSG 169094 169233 169333 129229 120972 817863 QT10460U21MS 169088 169227 169327 QT10460U21MSG 129226 120969 817864 QT10580N21MS 169095 169234 169334 QT10580N21MSG 129230 120973 817865 QT10580U21MS 169089 169228 169328 QT10580U21MSG 129227 120970 817866 QT10650N21MS 169096 169235 169335 QT10650N21MSG 129231 120974 817867 QT10820U21MS 169090 169229 169329 QT10820U21MSG 129228 120971 817868 QT10950N21MS 169097 169236 169336 QT10950N21MSG 129232 120975 817869 QT11100N21MS 169098 169237 169337 QT11100N21MSG 129233 120976 817870 QT11400N21MS 169099 169238 169338 QT11400N21MSG 129234 120977 817871 QT30008N21MS QT30008N21MSG 169119 169490 169573 129257 129511 817872 QT30017N21MS 169120 169491 169574 QT30017N21MSG 129258 129512 817873 QT30031N21MS 169121 169492 169575 QT30031N21MSG 129259 129513 817874 QT30044N21MS 169122 169493 169576 QT30044N21MSG 129260 129539 817875 QT30058N21MS 169123 169494 169577 QT30058N21MSG 129261 129540 817876 QT30072N21MS QT30072N21MSG 169124 169495 169578 129262 129541 817877 QT30085N21MS 169125 169496 169579 QT30085N21MSG 129263 129542 817878 QT30105N21MS 169126 169497 169580 QT30105N21MSG 129264 129543 817879 QT30145N21MS 169127 169498 169581 QT30145N21MSG 129265 129544 817880 QT30170N21MS 169128 169499 169582 QT30170N21MSG 129266 129545 817881 QT30210N21MS QT30210N21MSG 169129 169500 169583 129267 129546 817882 QT30310N21MS 169130 169501 169584 QT30310N21MSG 129268 129547 817883 QT30390N21MS 169131 169502 169585 QT30390N21MSG 129269 129548 817884 QT30460N21MS 169132 169503 169586 QT30460N21MSG 129270 129549 817885 QT30580N21MS 169133 169504 169587 QT30580N21MSG 129271 129550 817886 QT30650N21MS 169134 169505 169588 QT30650N21MSG 129272 129551 817887 QT30950N21MS 169135 169506 169589 QT30950N21MSG 129273 129552 817888 QT31100N21MS 169136 169507 169590 QT31100N21MSG 129274 129553 817889 QT31400N21MS 169137 169508 169591 QT31400N21MSG 129275 129554 817890 NEMA ratings. Recommended unit type and motor ratings Light Duty - NEMA 10 Normal Duty - NEMA 20 Heavy Duty - NEMA 30 Current Current Current 230V 460V 575V 230V 460V 575V 230V 460V 575V Cat. No. Ref. No. rating rating rating A HPHPHP A HP HP HP A HPHPHP Mains voltage 8 2 5 - 8 2 5 - 8 2 5 - QT10008U21MS 169075 230-500VAC 17 5 10 - 17 5 10 - 12 3 7.5 - QT10017U21MS 169076 34 10 25 - 31 10 20 - 31 10 20 - QT10031U21MS 169077 54 20 40 - 44 15 30 - 44 15 30 - QT10044U21MS 169078 65 20 50 - 58 20 40 - 55 20 40 - QT10058U21MS 169079 72 25 50 - 72 25 50 - 66 20 50 - QT10072U21MS 169080 104 40 75 - 85 30 60 - 80 30 60 - QT10085U21MS 169081 130 50 100 - 105 40 75 - 99 40 75 - QT10105U21MS 169082 156 60 125 - 145 50 100 - 130 50 100 - QT10145U21MS 169083 170 60 125 - 170 60 125 - 134 50 100 - QT10170U21MS 169084 262 100 200 - 210 75 150 - 203 75 150 - QT10210U21MS 169085 387 150 300 - 310 100 250 - 310 100 250 - QT10310U21MS 169086 414 150 350 - 390 150 300 - 361 150 300 - QT10390U21MS 169087 480 200 400 - 460 150 350 - 432 150 350 - QT10460U21MS 169088 610 250 500 - 580 200 400 - 552 200 400 - QT10580U21MS 169089 820 - - - 820 250 500 - 690 250 500 - QT10820U21MS 169090 Mains voltage 8 - 5 5 8 - 5 5 8 - 5 5 QT20008U21MS 169100 17 - 10 15 17 - 10 15 12 - 7.5 10 QT20017U21MS 460-600VAC 169101 34 - 25 30 31 - 20 25 31 - 20 25 QT20031U21MS 169102 54 - 40 50 44 - 30 40 44 - 30 40 QT20044U21MS 169103 65 - 50 60 58 - 40 50 55 - 40 50 QT20058U21MS 169104 72 - 50 60 72 - 50 60 66 - 50 60 QT20072U21MS 169105 104 - 75 100 85 - 60 75 80 - 60 75 QT20085U21MS 169106 130 - 100 125 105 - 75 100 99 - 75 100 QT20105U21MS 169107 156 - 125 150 145 - 100 150 130 - 100 125 QT20145U21MS 169108 170 - 125 150 170 - 125 150 134 - 100 125 QT20170U21MS 169109 262 - 200 250 210 - 150 200 203 - 150 200 QT20210U21MS 169110 387 - 300 400 310 - 250 300 310 - 250 300 QT20310U21MS 169111 414 - 350 400 390 - 300 400 361 - 300 300 QT20390U21MS 169112 480 - 400 500 460 - 350 400 432 - 350 400 QT20460U21MS 169113 610 - 500 - 580 - 400 400 552 - 400 500 QT20580U21MS 169114 820 - - - 820 - 500 500 690 - 500 - QT20820U21MS 169115 9 ASTAT XT Unit confi guration QT 1 0008 U 2 1 M S ASTAT XT range Main voltage 230-500V 1 460-600V 2 690V 3 Current ratings (1) UL certification UL U non-UL N (2) Control voltage 110VAC 1 230VAC 2 (3) Digital inputs, voltage 90-230VAC 1 24VDC 2 Communications Standard M Profibus P DeviceNet D Versions Standard S International SG (1) - ASTAT XT up to 600V, and up to 170A (Cat Numbers up to QT10170_ or up to QT20170) are always cUL certifi ed. Option “N” not available - Units QT2, from QT20008_, up to QT20820_ are always cUL certifi ed. Option “N” not available. - Units QT1, or QT2 from QTx0950_ up to QTx1400 are not UL certifi ed. Option “U” not available. - Units QT3__, rated to 690V, are not UL certifi ed. Option “U” not available (2) ASTAT XT standard control voltage confi guration is option 2, voltage 230VAC, +10%, -15% (3) ASTAT XT standard confi guration for inputs is option 1, voltage 90-230VAC, +10%, -15% OPTIONS: - Remote mounting kit for keypad that includes cable (3m), remote keypad box, dummy cover, frame and brackets: - Frame A QTAKPADKIT1 169072 - Frame B and others QTAKPADKIT2 169073 For the international version: - Frame A QTAKPADKIT1SG 129052 - Frame B and others QTAKPADKIT2SG 129053 10 Digital soft starters Technical data ASTAT XT Technical data Ratings Main voltage 3ph AC supply 230 to 500VAC +10%, -15% for QT1xxx units 460 to 600VAC +10%, -15% for QT2xxx units 690VAC +10%, -15% for QT3xxx units Starter current rating for 3ph AC motors From 8A up to 1400A. Motor current rating 3ph Induction motors Motor rated current from 50% to 100% of starter current 1ph AC supply 230VAC, +10, -15%, 50/60Hz or Control voltage 110VAC, +10, -15%, 50/60Hz (optional) Frequency range 50/60Hz systems Wide from 45Hz to 65Hz. Auto-tracking frequency range Digital inputs voltage 90-230Vac, +10 -15%, 50/60Hz 24Vdc, +10%, -15% (optional) Control specifi cations Control system Digital control with microcontroller. Starting ramp, with progressive increase in voltage and current limitation Operation mode In-Line (three wires) or Inside-Delta (six wires) of the motor Run operation Soft Start and Soft stop by multiple choices, including torque control both at start or Stop phases Operator interface By LCD display, keypad and Indication LEDs Display: LCD with two rows, 16 characters each Type: Multilanguage, dip-switch selectable for English, Italian, Spanish and German Keys: Six keys, Mode, reset, Set, Select and Up / Down LEDs: ON, Start, Run, Soft Stop, Stop, Save / Slow Speed, Dual Set / Reverse and Fault Initial voltage 10-50% Un. Up to 80% with expanded settings function 100-400% In. Can be extended up to 500%, by using extended settings Starting current Acceleration ramp time 1-30 sec. Can be extended up to 90 sec, by using extended settings Deceleration ramp time 1-30 sec. Can be extended up to 90 sec, by using extended settings Current limitation 100-400% of motor rated current. Can be extended up to 500% by using extended settings Bypass By external contactor while motor is full protected by ASTAT XT Motor current, line voltage, motor thermistor resistance, test and maintenance and statistics Monitoring Environmental conditions -10°C up to 60ºC, with current derating by 2.5% per °C, from 50ºC Operating temperature Storage temperature -20ºC up to 70ºC Maximum altitude Up to 1000 mts. Ask your dealed for installation at higher altitude Humidity 95% at 50ºC or 98% at 45ºC Protection degree IP20 for units up to 72A, IP00 for units from 85A up to 1400A Pollution degree Class 3 Standards Global standards CE for the full trange. UL, cUL for specifi ed units up to 820A EMC emissions EN 61000-6-4 CISPR 11 Class A Immunity EN 61000-6-2 ESD 8KV air, IEC 801-2; Electric RF fi eld 10 V/m, 20-1000Mhz, IEC 801-3 Fast transients 2KV, IEC 801-4 Safety EN 600947-1 Related to safety requirements. UL508C 11 ASTAT XT Functions Available standard functions Soft start and soft stop ASTAT XT is provided with a soft start and soft stop features, including fi ve independent acceleration and decelertaion curve models. The factory default curve is used for general purpose, other three are used for pump control and the last one for torque control. Pump control Specifi c function for pump control, that avoids overpressure in the system at the end of acceleration phase and suppresses the hammering at stopping phase. Torque control Provides a smoth time controlled torque ramp acelleration and deceleration, with linear deceleration of the torque resulting in a close to linear speed deceleration, thus eliminating stall conditions. In line / Inside delta ASTAT XT allows either traditional Line operation or Inside Delta operation. When the ASTAT XT is installed to operate Inside Delta, the individual phases of the starter are connected in series with the individual motor windings (six wiring connections like the Start-Delta starters), thus reducing the current x1.73, and allowing the use of a much smaller starter (x1.5 less than motor rated current). Bypass ASTAT XT allows bypass operation using an external contactor, controlled ON/OFF by starter function EOR (End Of Ramp). The starter is provided with three dedicated power terminals to facilitate wirings to the bypass contactor. ASTAT XT protections to motor are enabled, even in bypass. Kick start This function allows to start high friction loadsthat require high starting torque for a short period of time. When this function is enabled, a pulse of 80% Un during an adjustable time from 0 to 1sec is given to the motor. After this pulse the output voltage is ramping down to starting voltage setting, before ramping up again to full voltage. End of ramp Detects end of acceleration and outputs a signal by an dry relay contact. This signal can be delayed by an adjustable timer from 0-120 sec. Lock-out Allows to control the number of startings into a period of time, then protecting both motor and ASTAT. Dual settings By this function, ASTAT XT is able to control a secondary motor Dual setting of Starting voltage, Starting current, Current limit, Ramp up, Ramp down and Motor current parameters can be selected by using one of the programmable ASTAT XT inputs. Energy saving Activated when the motor has a light load for extended periods of time, then reducing the output voltage level and decreasing the reactive current and motor copper/Iron losses. This function can be enabled or disabled by dedicated parameters in ASTAT XT. Slow speed Function that allows the motor to run at 1/6 constant rated speed, for a short period of time of maximum 30sec. This function supports forward and reverse operation. Auto reset This function allows the ASTAT XT automatic recover after a fault caused by Undervoltage, Undercurrent or Phase lost. Auto-reset can be programed up to maximum 10 attempts. Cooling fan control Allows thre method of control for the ASTAT´s built-in cooling fans. - Continuous operation - Controlled by an external Input - Automatically OFF controlled, after fi ve minutes ASTAT XT is stopped Generator supply This is a specifi c function useful when the starter is powered from a diesel generator rather than from commercial power supply. The function is enabled by an internal Dip switch, and helps to minimize the negative effects caused by the generator´s voltage fl uctuations during starting. Keypad lock This function is enabled by means of starter´s internal dipswitch, then locking the keypad. This is usefull to prevent undesired parameter modifi cations. Built-in communications ASTAT XT includes a ModBus RTU communications protocol. Communications are carried out through a half duplex RS485 port, with maximum baudrate of 9600, supporting up to 247 stations. Statistic data ASTAT XT records useful data for maintenance and start up - Last 10 trip events - Statistical data like number of starts, number of trip events and elapsed RUN time. - Last trip data information of motor current, starting current and acceleration time. Motor and starter protection Overload Trips the ASTAT XT when current exceeds the overload trip level according IEC Class 10, 20 or NEMA 10, 20, 30. Motor thermistor Trips when motor thermistor resinstance decreases below trip level set ASTAT XT allows both PTC or NTC sensors, with adjustable trip level. Too many starts Trips if the number of starts, during duty cycle time exceeds the preset number. Long start time Trips if output voltage does not reach rated voltage at the preset Max. Start time. O/C JAM fault Trips under the following conditions: - Instantaneously when current exceeds 8.5 x ASTAT XT current - During starting when current exceeds 8.5 x motor current - During running when current exceeds 200-850% of motor current O/C JAM has a programmable triping delay of 0-5 seconds Undercurrent Trips when line current drops below the preset level for the preset time. Undervoltage Trips when line voltage drops below the preset level for the preset time. Overvoltage Trips when line voltage increases above a preset level for a preset time. Phase loss Trips if 1 or 2 phases are lost. Frequency loss Trips if frequency is not in the range of 40-66.6Hz. Phase sequence Trips if line phase sequence is wrong. Slow speed time Trips when operating at slow speed for extended periods Trips the ASTAT XT when one or more motor phases is not properly connected to ASTAT XT’s load terminals Wrong connection or if there is an internal disconnection in the motor winding. Shorted SCR Trips and prevents starting if any SCR is short-circuited or when motor windings are shorted. Over temperature Heat-sink over-temperature. Trips the ASTAT XT when the heat-sink temperature rises above 85°C. External fault Trips the ASTAT XT when a NO contact between terminals 19-21 closes for over two seconds. Wrong parameters Parameters not transferred from RAM to EEPROM or vice versa. OC or wrong CON Trips when the ASTAT XT is connected inside Delta and wrong connection or overcurrent is detected. 12 Digital soft starters Overload protections ASTAT XT Overload protections - Thermal characteristics The ASTAT XT allows motor protection according IEC Class 10 or Class 20 and NEMA 10, 20 or 30. User free selectable by ASTAT internal dedicated parameter. IEC Class 10 IEC Class 20 Sec. Sec. 10000 10000 1000 1000 100 100 COLD COLD 10 10 HOT HOT 1 1 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 Multiples of motor FLA Rating In Multiples of motor FLA Rating In NEMA 10 Light Duty NEMA 20 Sec. Sec. 10000 10000 1000 1000 100 100 COLD COLD 10 10 HOT HOT 1 1 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 Multiples of motor FLA Rating In Multiples of motor FLA Rating In Maximum number starting /hour NEMA 30 Ramp time Sec. 10s 20s 30s 10000 224 12 8 Starting current 3168 5 (1) 1000 I/In 4126 4 100 (1) In= rated current of ASTAT XT in the specifi ed class IEC/NEMA COLD 10 HOT 1 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 Multiples of motor FLA Rating In 13 ASTAT XT I/O Wiring, basic scheme CT1 1L1 2T1 A CT2 3L2 4T2 M 3ph B 5L3 6T3 C L 10 11 Control supply F Inmediate RUN 12 N Stop 4 13 Soft Stop 5 14 Fault relay Start 6 15 Energy save/Slow speed/reset 7 16 D.Adj./Reversing/Reset 8 17 EOR (End Of Ramp) relay Common 9 18 External fault input 19 SG RS485 port D- Neutral 21 D+ Ground Grd 31 (-) T1 28 Analogue output 32 (+) Thermistor input T2 29 Ground 30 V- Power supply CL Signal CAN-H Dr Drain CH Signal CAN-L V+ Power supply Profibus (option) Note: Profi bus or DeviceNet options cannot be ordered separately. For those communication networks, please order the ASTAT XT with the required option built-in (see pages 8 and 9). 14 Digital soft starters Main supply DeviceNet (option) I/O terminal board ASTAT XT I/O terminal board specifi cations Power I/O terminals Terminals Function Description 1L1, 3L2, 5L3 Mains input 3ph Input voltage according ASTAT XT main voltage option rating (Option 1, QT1_) 230-500VAC, +10%/-15% 50/60Hz (Option 2, QT2_) 460-600VAC, +10%/-15% 50/60Hz (Option 3, QT3_) 690VAC, +10%/-15% 50/60Hz 2T1, 4T2, 6T3 Output to motor Power output terminals to 3ph AC motor Bypass Bypass terminals for external bypass contactor A, B, C G Ground ASTAT XT, ground connection Control power supply L, N Control supply 110VAC or 220VAC, according ASTAT XT control voltage rating F Fan control Cooling fan external control, together with jumper J1 Control voltage and fan consumption VA: QTx0008 to QTx0031: No fan. Total consumption: 150VA QTx0044 to QTx0072: Fan 35 VA. Total consumption 185VA QTx0085 to QTx0170: Fan 60 VA. Total consumption 210VA QTx0210 to QTx0390: Fans 105VA. Total consumption 255VA QTx0390 to QTx 1400A : Fans 150VA. Total consumption 300VA Digital inputs 4 Stop Dedicated input to Stop 5 Soft Stop Dedicated input to Soft Stop 6 Start Dedicated input to Start 7 Progammable inputs Programmable to functions Energy saving, slow speed and reset 8 Progammable inputs Programmable to functions Dual set, Reverse and Reset 9 Common Common terminal for digital inputs from 4, 5, 6, 7 and 8 Operating voltage of digital inputs from 4 to 9 Digital Input hardware is operated according either of below ordered voltage ratings (Option 1, standard) from 90 to 230VAC +10%, 50/60Hz (Option 2, optional) 24VDC +10%/ -15% Other inputs 19, 21 External fault Requires a free voltage relay contact, to detect external fault Neutral This terminal may be connected to mains neutral when available 21 28, 29 Motor thermistor PTC or NTC programable input for motor thermistor protection The input can be enabled or disabled, and programmed at desired trip level resistance Digital outputs 10, 11, 12 RUN Run relay with NO and NC dry contact. Programmable ON delay 13, 14, 15 FAULT Fault to ON or Fault to OFF programmable function 16, 17, 18 EOR End of ramp relay. Programmable ON delay Relay outputs ratings Max rating: 8A, 250VAC, 2000VA max Analogue output 31, 32 Current output Range 0 to 2xIn. Programmable 0-10VDC, 0-20mA or 4-20mA. 30 Ground Ground terminal for analogue output Communications D+, D-, SG RS485 terminals RS485 communication port, half duplex for ModBus protocol Baudrate 1200, 2400, 4800, 9600 BPS D-9 connector Profi bus port Optional Profi bus communications port V+, CL, Dr, CH, V- DeviceNet terminals Optional Devicenet communications port 15 ASTAT XT Application wiring diagrams (1) Basic diagram without line contactor With Soft Start and coast to Stop L1 L2 L3 by permanent command control 1 3 5 Q1 2 4 6 1 2 T1 1 2 Q3 3 4 Q2 0 STOP I START F1 A1 EOR FAULT RUN R R R GND 18 17 16 15 14 13 12 11 10 U1 V1 W1 M ~ 3 (1) Basic diagram without line contactor L1 L2 L3 With Soft Start and Soft Stop by permanent command control 1 3 5 Q1 2 4 6 1 2 T1 12 Q3 3 4 Q2 0 STOP I START F1 A1 EOR FAULT RUN R R R GND 18 17 16 15 14 13 12 11 10 U1 V1 W1 M ~ 3 (1) Schemes are given for information purposes. Add additional emergency safety stop, if it is required for your application. Remarks 1. Check coordination tables for proper selection of breaker and line contactor. 2. Control voltage and control input voltage are from same source in above example. Please check manuals if you have different sources for control voltage and control input voltage. 3. Semiconductor fuses “F” are only required for Type 2 coordination. Please check coordination tables. 4. In spite of ASTAT XT can operate without line contactor, the use of a line contactor will increase the operation safety. Anyway provide a way to switch off the breaker in case of an emergency. 5. Line and bypass contactors should be dimensioned according AC1 category. 16 Digital soft starters 2T1 1L1 2T1 1L1 4T2 3L2 4T2 3L2 6T3 5L3 6T3 5L3 N N COMMON 9 COMMON 9 L L STOP 4 STOP 4 SOFT STOP 5 SOFT STOP 5 START 6 START 6 Wiring diagrams ASTAT XT Application wiring diagrams (1) Basic diagram without line contactor L1 L2 L3 With Soft Start and Soft Stop by push-buttons control 1 3 5 Q1 2 4 6 1 2 T1 12 Q3 3 4 Q2 STOP F1 START A1 EOR FAULT RUN R R R GND 18 17 16 15 14 13 12 11 10 U1 V1 W1 M 3 ~ (1) Basic diagram with line contactor With Soft Start and coast to Stop L1 L2 L3 by push-buttons control 1 3 5 Q1 2 4 6 1 2 T1 12 13 Q1 Q3 .2 14 3 4 13 31 STOP KM1 K1 Q2 14 34 1 3 5 KM1 .8 2 4 6 21 11 START K1 K1 24 14 A1 A1 14 10 F1 FAULT RUN RELAY 15 RELAY 12 A1 A1 K1 KM1 A2 A2 A1 EOR FAULT RUN R R R GND 18 17 16 15 14 13 12 11 10 U1 V1 W1 M 3 ~ (1) Schemes are given for information purposes. Add additional emergency safety stop, if it is required for your application. Remarks 1. Check coordination tables for proper selection of breaker and line contactor. 2. Control voltage and control input voltage are from same source in above example. Please check manuals if you have different sources for control voltage and control input voltage. 3. Semiconductor fuses “F” are only required for Type 2 coordination. Please check coordination tables. 4. In spite of ASTAT XT can operate without line contactor, the use of a line contactor will increase the operation safety. Anyway provide a way to switch off the breaker in case of an emergency. 5. Line and bypass contactors should be dimensioned according AC1 category. 17 2T1 1L1 2T1 1L1 4T2 3L2 4T2 3L2 6T3 5L3 6T3 5L3 N N COMMON 9 COMMON 9 L L STOP 4 STOP 4 SOFT STOP 5 SOFT STOP 5 START 6 START 6 ASTAT XT Application wiring diagrams (1) Basic diagram with line contactor L1 L2 L3 With Soft Start and Soft Stop by push-buttons control 1 3 5 Q1 2 4 6 1 2 T1 12 13 Q1 Q3 .2 14 3 4 13 31 STOP KM1 K1 Q2 14 34 1 3 5 KM1 .8 2 4 6 21 11 START K1 K1 24 14 A1 A1 14 10 F1 FAULT RUN 15 12 RELAY RELAY A1 A1 K1 KM1 A2 A2 A1 EOR FAULT RUN R R R GND 18 17 16 15 14 13 12 11 10 U1 V1 W1 M ~ 3 (1) Basic diagram with line and bypass contactors With Soft Start and Soft Stop L1 L2 L3 by push-buttons control 1 3 5 Q1 2 4 6 1 2 T1 12 13 Q1 Q3 14 3 4 13 31 STOP KM1 K1 Q2 14 34 1 3 5 KM1 =8/1.8 2 4 6 21 11 K1 START K1 24 14 A1 A1 A1 F1 14 10 16 FAULT RUN EOA 15 12 18 RELAY RELAY RELAY A1 A1 A1 K1 KM1 KM2 A2 A2 A2 1 3 5 A1 KM2 A B C EOR FAULT RUN =8/1.9 2 4 6 R R R BPC GND 18 17 16 15 14 13 12 11 10 U1 V1 W1 M ~ 3 (1) Above schemes are given for information purposes. Add additional emergency safety stop, if it is required for your application. Remarks 1. Check coordination tables for proper selection of breaker and line contactor. 2. Control voltage and control input voltage are from same source in above example. Please check manuals if you have different sources for control voltage and control input voltage. 3. Semiconductor fuses “F” are only required for Type 2 coordination. Please check coordination tables. 4. Line and bypass contactors should be dimensioned according AC1 category. 18 Digital soft starters 2T1 1L1 4T2 3L2 2T1 1L1 4T2 3L2 6T3 5L3 6T3 5L3 N N COMMON 9 COMMON 9 L L STOP 4 STOP 4 SOFT STOP 5 SOFT STOP 5 START 6 START 6 Wiring diagrams ASTAT XT Application wiring diagrams (1) Basic diagram in “Inside Delta” confi guration with line and bypass contactors L1 L2 L3 With Soft Start and Soft Stop by push-buttons control 1 3 5 Q1 2 4 6 1 2 T1 12 13 Q3 Q1 14 3 4 13 31 STOP KM1 K1 1 3 5 Q2 14 34 KM1 2 4 6 21 11 K1 START K1 24 14 A1 A1 A1 14 10 16 F1 FAULT RUN EOA 15 12 18 RELAY RELAY RELAY A1 A1 A1 A1 K1 KM1 KM3 KM2 A2 A2 A2 A2 1 3 5 1 3 5 A1 A B C KM3 KM2 EOR FAULT RUN 2 4 6 2 4 6 R R R BPC GND 18 17 16 15 14 13 12 11 10 U1 V1 W1 PE U2 V2 W2 (1) Above schemes are given for information purposes. Add additional emergency safety stop, if it is required for your application. Remarks 1. Check coordination tables for proper selection of breaker and line contactor. 2. Control voltage and control input voltage are from same source in above example. Please check manuals if you have different sources for control voltage and control input voltage. 3. Semiconductor fuses “F” are only required for Type 2 coordination. Please check coordination tables. 4. Wrong connection of the motor, or the ASTAT XT when it is inside-delta connected may seriously damage the motor or the ASTAT XT. Please check additional details given in the ASTAT XT instruction manual. 5. Line and bypass contactors should be dimensioned according AC1 category. 19 2T1 1L1 4T2 3L2 6T3 5L3 N COMMON 9 L STOP 4 SOFT STOP 5 START 6 ASTAT XT Coordination Type 1 Type 1 coordination with GE circuit breakers Record Plus Soft starter Record Plus circuit breakers Rated current Overload current Frame type O/L type Breaking capacity AA kA 8 16 FD63 LTMD 16 65 17 40 FD63 LTMD 40 65 31 50 FD63 LTMD 50 65 44 63 FD160 LTMD 63 65 58 80 FD160 LTMD 80 65 72 80 FE160 LTMD 80 65 85 125 FE160 SMR1-125 65 105 160 FE160 SMR1-160 65 145 160 FE160 LTMD 160 65 170 250 FE250 LTMD 250 65 210 250 FE250 LTMD 250 65 310 400 FG630 SMR1-400 65 390 400 FG400 SMR1-400 65 460 630 FG630 SMR1-630 65 580 630 FG630 SMR1-630 65 650 800 FK800 SMR1s-800 50 820 1250 FK1250 SMR1s-1250 50 950 1250 FK1250 SMR1s-1250 50 1100 1250 FK1250 SMR1s-1250 50 1400 1600 FK1600 SMR1s-1600 50 Type 1 coordination with Type aM Siba fuses Siba aM fuses Soft starter Rated current Rated current Part No. Size Un Type Breaking capacity AA kA 8 16 20 477 08.16 0 690 aM 120 17 20 20 477 08.20 0 690 aM 120 31 35 20 477 08.35 0 690 aM 120 44 50 20 477 08.50 0 690 aM 120 58 80 20 209 08.80 0 690 aM 120 72 100 20 209 08.100 0 690 aM 120 85 125 20 209 08.125 0 690 aM 120 105 160 20 210 08.160 0 690 aM 120 145 200 20 211 08.200 1 690 aM 120 170 200 20 211 08.200 1 690 aM 120 210 250 20 211 08.250 1 690 aM 120 310 400 20 212 08.400 2 690 aM 120 390 500 20 213 08.500 3 690 aM 120 460 630 20 213 08.630 3 690 aM 120 580 800 20 225 08.800 4 690 aM 120 650 800 20 225 08.800 4 690 aM 120 820 1000 20 225 08.1000 4 690 aM 120 950 2x630 2x20 213 08.630 2x3 690 aM 120 1100 2x800 2x20 225 08.800 2x4 690 aM 120 1400 2x800 2x20 225 08.800 2x4 690 aM 120 20 Digital soft starters Coordination tables ASTAT XT Coordination Type 2 Type 2 coordination with Bussman fuses Soft starter Bussman fuses DIN 43620 2 Rated current A sec Rated current Part No. Size Un Type Breaking capacity AA kA 8 400 40 170M3808D 1 690 H.S.D.I. 200 17 5000 63 170M3810D 1 690 H.S.D.I. 200 31 10000 125 170M3813D 1 690 H.S.D.I. 200 44 12000 160 170M3814D 1 690 H.S.D.I. 200 58 15000 160 170M3814D 1 690 H.S.D.I. 200 72 18000 200 170M3815D 1 690 H.S.D.I. 200 85 50000 250 170M3816D 1 690 H.S.D.I. 200 105 60000 315 170M3817D 1 690 H.S.D.I. 200 145 10000 315 170M3817D 1 690 H.S.D.I. 200 170 140000 400 170M3819D 1 690 H.S.D.I. 200 210 200000 500 170M4864D 1 690 H.S.D.I. 200 310 600000 500 170M4864D 1 690 H.S.D.I. 200 390 700000 800 170M5814D 2 690 H.S.D.I. 200 460 800000 900 170M6813D 3 690 H.S.D.I. 200 580 1200000 1000 170M6814D 3 690 H.S.D.I. 200 650 2000000 2x800 2x170M5814D 2x2 690 H.S.D.I. 200 820 2000000 2x800 2x170M5814D 2x2 690 H.S.D.I. 200 950 4500000 2x1000 2x170M5816D 2x2 690 H.S.D.I. 200 1100 4500000 2x1100 2x170M6892D 2x2 690 H.S.D.I. 200 1400 6500000 2x1400 2x170M8555D 2x3 690 H.S.D.I. 200 For Type 2 coordination Use fuses for semiconductor protection to protect the ASTAT XT soft starter from a short circuit. Fuses for semiconductor protection give excellent results because they have low I²t values and high interruption ratings. Recommended fuse selection procedure Fuse rated voltage Choose minimum fuse rated voltage which is above the rated voltage of the mains. Fuse rated current Select a fuse which is able to carry 8 times the rated ASTAT XT soft starter current for 30 seconds (this is double the maximum ASTAT XT soft starter current for the maximum acceleration time). Fuse I²t Verify that the I²t value of the fuse is less than or equal to the I²t value of the thyristor in the ASTAT XT soft starter as shown in the table. 21 ASTAT XT Dimensions and weights Cat. No.: QTx0008U_ , QTx0017U_ , QTx0031U_ , QTx0044U_ , QTx0058U_ , QTx0072U_ 158 7 Bypass 1L1, 3L2, 5L3 A B C GND M5 2T1, 4T2, 6T3 130 D1 153 D2 Power terminal size (mm²) Cat. No Dimensions Input Bypass Output Weight (kg) D1 D2 1L1, 3L2, 5L3 A, B, C 2T1, 4T2, 6T3 QTx0008U__ 160 182.5 16 16 16 4.2 QTx0017U__ 160 182.5 16 16 16 4.2 QTx0031U__ 160 182.5 16 16 16 5.3 QTx0044U__ 207 229.5 16 16 35 6.7 QTx0058U__ 207 229.5 16 16 35 6.7 QTx0072U__ 207 229.5 35 35 35 6.7 IEC and UL certifi ed units Cat. No.: QTx0085U_ , QTx0105U_ 278 188 104.5 65.5 65.5 137 4 GND M6 9 20 1L1, 3L2, 5L3 O 8.5 2T1, 4T2, 6T3 71.8 32.7 32.8 32.7 32.8 117 4 Bypass 200 A B C 243 274 Cat. No. Weight (kg) QTx0085U__ 15.2 QTx0105U__ 15.2 IEC and UL certifi ed units 22 Digital soft starters 385 365 310 298 355 15 Dimensions ASTAT XT Dimensions and weights Cat. No.: QTx0145U_ , QTx0170U_ 278 188 99.5 65.5 65.5 137 4 GND M6 9 20 1L1, 3L2 O 8.5 2T1, 4T2, 6T3 66.8 32.7 32.8 32.7 32.8 32.7 117 4 Bypass 200 A B C 274 244 Cat. No. Weight (kg) QTx0145U__ 15.2 QTx0170U__ 15.2 IEC and UL certifi ed units Cat. No.: QTx0210U_ , QTx0310U_ , QTx0390U_ , QTx0460N_ 182.2 5 160 43.5 125 125 54.2 5 1L1, 3L2, 5L3 By Pass A B C O10 30 9.5 GND M8 2T1, 4T2, 6T3 125 125 43.5 182.2 5 380 299.4 Cat. No. Dimensions Weight (kg) H1 H2 H3 H4 QTx0210U__ 455 425 414 427 32.7 IEC and UL certifi ed units QTx0310U__ 455 425 414 427 32.7 QTx0390U__ 455 425 414 427 32.7 This 460A frame is only IEC certifi ed. QTx0460N__ 555 525 528.5 527 58.4 Please consult dimensions of 460A frame for UL in page 26 23 385 365 H1 H2 15 355 15 H3 H4 ASTAT XT Dimensions and weights Cat. No.: QTx0580N_ 180 221.7 5 150 150 50.5 171.7 5 1L1, 3L2, 5L3 Bypass A B C 40 9.5 O 13.5 GND M8 2T1, 4T2, 6T3 50.5 150 150 216.7 5 309.4 470 Cat. No. Weight (kg) QTx0580U__ 63.2 Non-UL certifi ed unit Cat. No.: QTx0650N_ 180 221.7 5 150 150 50.5 171.7 5 1L1, 3L2, 5L3 Bypass A B C 9.5 O 13.5 40 GND M8 2T1, 4T2, 6T3 50.5 150 150 216.7 5 309.4 470 Cat. No. Weight (kg) QTx0650N__ 64.8 Non-UL certifi ed units 24 Digital soft starters 655 655 615 20 615 20 528 528 542 542 600 600 615 615 Dimensions ASTAT XT Dimensions and weights Cat. No.: QTx0950N_ 625 292.4 195 195 234.5 9.5 2T1, 4T2, 6T3 GND M8 10 114 50 1L1, 3L2, 5L3 17.5 45 O10.5 10 114 245 74.7 80 10 114 440 Remarks 1. This unit must be operated with a bypass contactor 2. Add space for curr ent transformers (supplied separately from the main unit) and bus bars for preparation for bypass Approximate current transformers dimensions: W=240mm, H=130mm, D=90mm Cat. No. Weight (kg) QTx0950N__ 86.7 Non-UL certifi ed unit Cat. No.: QTx1100N_ , QTx1400N 131.5 230 230 94 10 80 1L1, 3L2, 5L3 O10.5 45 O9 16.5 230 230 230 GND M10 9 230 230 45 2T1, 4T2, 6T3 O10.5 80 266 10 191.5 230 230 376.8 723 Remarks 1. Units must be operated with a bypass contactor 2. Add space for curr ent transformers (supplied separately from main unit) and bus bars for preparation for bypass Approximate current transformers dimensions: W=240mm, H=130mm, D=90mm. (for 1100A unit, Cat. No. QTx1100N__ Cat. No. Weight (kg) W=270mm, H=155mm, D=90mm. (for 1400A unit, Cat. No. QTx1400N__ QTx1100N__ 169.8 QTx1400N__ 175.5 Non-UL certifi ed unit 25 659 1100 640 8 165 626.5 20 45 20 712 29 45 786 20 45 ASTAT XT Dimensions and weights Cat. No.: QTx0460U_ 625 292.4 195 195 234.5 9.5 GND M8 25 50 2T1, 4T2, 6T3 1L1, 3L2, 5L3 25 Bypass A B C O10 74.2 6 65 130 65 130 65 80 155.2 6 Cat. No. Weight (kg) QTx0460U__ 61.8 UL certifi ed unit Cat. No.: QTx0580U_ , QTx0820U_ 625 292.4 195 195 234.5 9.5 GND M8 25 50 2T1, 4T2, 6T3 1L1, 3L2, 5L3 25 Bypass A B C 74.2 6 195 195 77 73.5 155.2 6 Cat. No. Weight (kg) QTx0580U__ 69.5 QTx0820U__ 69.5 UL certifi ed unit 26 Digital soft starters 640 626.5 640 626.5 25 13 25 13 13 13 25 25 659 659 818 818 ASTAT Notes .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... .......................................... 27 ASTAT Numerical index By reference number By catalogue number Ref. No. Typbez. Pag. Ref. No. Typbez. Pag. Cat. No. Ref. No. Pag. Cat. No. Ref. No. Pag. 120000 169088 QT10460U21MS 9 QA... QT20310U21MS 169111 9 120881 QA02P008S 2 QT10580U21MS 9 QA02P008S 120881 2 169112 9 169089 QT20390U21MS 120882 QA02P017S 2 169090 QT10820U21MS 9 QA02P017S 120882 2 QT20460U21MS 169113 9 120883 QA02P022S 2 169094 QT10460N21MS 9 QA02P022S 120883 2 QT20580U21MS 169114 9 QA02P031S 2 120884 2 120884 169095 QT10580N21MS 9 QA02P031S QT20820U21MS 169115 9 120885 QA02P044S 2 QA02P044S 120885 2 169096 QT10650N21MS 9 QT30008N21MS 169119 9 120886 QA02P058S 2 169097 QT10950N21MS 9 QA02P058S 120886 2 QT30008N21MSG 129257 9 120892 QA12P008S 2 169098 QT11100N21MS 9 QA12P008S 120892 2 QT30017N21MS 169120 9 120893 QA12P017S 2 169099 QT11400N21MS 9 QA12P017S 120893 2 QT30017N21MSG 129258 9 QA12P022S 2 120894 2 120894 169100 QT20008U21MS 9 QA12P022S QT30031N21MS 169121 9 120895 QA12P031S 2 QA12P031S 120895 2 169101 QT20017U21MS 9 QT30031N21MSG 129259 9 120896 QA12P044S 2 169102 QT20031U21MS 9 QA12P044S 120896 2 QT30044N21MS 169122 9 120897 QA12P058S 2 169103 QT20044U21MS 9 QA12P058S 120897 2 QT30044N21MSG 129260 9 120898 QA22P008S 2 169104 QT20058U21MS 9 QA22P008S 120898 2 QT30058N21MS 169123 9 QA22P017S 2 120899 2 120899 169105 QT20072U21MS 9 QA22P017S QT30058N21MSG 129261 9 120900 QA22P022S 2 QA22P022S 120900 2 169106 QT20085U21MS 9 QT30072N21MS 169124 9 120901 QA22P031S 2 169107 QT20105U21MS 9 QA22P031S 120901 2 QT30072N21MSG 129262 9 120902 QA22P044S 2 169108 QT20145U21MS 9 QA22P044S 120902 2 QT30085N21MS 169125 9 120903 QA22P058S 2 169109 QT20170U21MS 9 QA22P058S 120903 2 QT30085N21MSG 129263 9 QA32P008S 2 120904 2 120904 169110 QT20210U21MS 9 QA32P008S QT30105N21MS 169126 9 120905 QA32P017S 2 QA32P017S 120905 2 169111 QT20310U21MS 9 QT30105N21MSG 129264 9 120906 QA32P022S 2 169112 QT20390U21MS 9 QA32P022S 120906 2 QT30145N21MS 169127 9 120907 QA32P031S 2 169113 QT20460U21MS 9 QA32P031S 120907 2 QT30145N21MSG 129265 9 120908 QA32P044S 2 169114 QT20580U21MS 9 QA32P044S 120908 2 QT30170N21MS 169128 9 120909 QA32P058S 2 QA32P058S 120909 2 169115 QT20820U21MS 9 QT30170N21MSG 129266 9 120910 QAOPTDIN 2 QT30008N21MS 9 QAOPTDIN 120910 2 169129 9 169119 QT30210N21MS 129000 169120 QT30017N21MS 9 QT QT30210N21MSG 129267 9 129213 QT10008U21MSG 9 169121 QT30031N21MS 9 QT10008U21MS 169075 9 QT30310N21MS 169130 9 129214 QT10017U21MSG 9 169122 QT30044N21MS 9 QT10008U21MSG 129213 9 QT30310N21MSG 129268 9 129215 QT10031U21MSG 9 QT10017U21MS 169076 9 169123 QT30058N21MS 9 QT30390N21MS 169131 9 129216 QT10044U21MSG 9 QT30072N21MS 9 QT10017U21MSG 129214 9 129269 9 169124 QT30390N21MSG 129217 QT10058U21MSG 9 169125 QT30085N21MS 9 QT10031U21MS 169077 9 QT30460N21MS 169132 9 129218 QT10072U21MSG 9 169126 QT30105N21MS 9 QT10031U21MSG 129215 9 QT30460N21MSG 129270 9 129219 QT10085U21MSG 9 169127 QT30145N21MS 9 QT10044U21MS 169078 9 QT30580N21MS 169133 9 129220 QT10105U21MSG 9 QT10044U21MSG 129216 9 169128 QT30170N21MS 9 QT30580N21MSG 129271 9 129221 QT10145U21MSG 9 QT30210N21MS 9 QT10058U21MS 169079 9 169134 9 169129 QT30650N21MS 129222 QT10170U21MSG 9 169130 QT30310N21MS 9 QT10058U21MSG 129217 9 QT30650N21MSG 129272 9 129223 QT10210U21MSG 9 169131 QT30390N21MS 9 QT10072U21MS 169080 9 QT30950N21MS 169135 9 129224 QT10310U21MSG 9 169132 QT30460N21MS 9 QT10072U21MSG 129218 9 QT30950N21MSG 129273 9 129225 QT10390U21MSG 9 QT10085U21MS 169081 9 169133 QT30580N21MS 9 QT31100N21MS 169136 9 129226 QT10460U21MSG 9 QT30650N21MS 9 QT10085U21MSG 129219 9 129274 9 169134 QT31100N21MSG 129227 QT10580U21MSG 9 169135 QT30950N21MS 9 QT10105U21MS 169082 9 QT31400N21MS 169137 9 129228 QT10820U21MSG 9 169136 QT31100N21MS 9 QT10105U21MSG 129220 9 QT31400N21MSG 129275 9 129229 QT10460N21MSG 9 169137 QT31400N21MS 9 QT10145U21MS 169083 9 129230 QT10580N21MSG 9 QT10145U21MSG 129221 9 129231 QT10650N21MSG 9 QT10170U21MS 169084 9 129232 QT10950N21MSG 9 QT10170U21MSG 129222 9 129233 QT11100N21MSG 9 QT10210U21MS 169085 9 QT11400N21MSG 9 129223 9 129234 QT10210U21MSG 129257 QT30008N21MSG 9 QT10310U21MS 169086 9 129258 QT30017N21MSG 9 QT10310U21MSG 129224 9 129259 QT30031N21MSG 9 QT10390U21MS 169087 9 129260 QT30044N21MSG 9 QT10390U21MSG 129225 9 QT30058N21MSG 9 169094 9 129261 QT10460N21MS 129262 QT30072N21MSG 9 QT10460N21MSG 129229 9 129263 QT30085N21MSG 9 QT10460U21MS 169088 9 129264 QT30105N21MSG 9 QT10460U21MSG 129226 9 129265 QT30145N21MSG 9 QT10580N21MS 169095 9 QT30170N21MSG 9 129230 9 129266 QT10580N21MSG 129267 QT30210N21MSG 9 QT10580U21MS 169089 9 129268 QT30310N21MSG 9 QT10580U21MSG 129227 9 129269 QT30390N21MSG 9 QT10650N21MS 169096 9 129270 QT30460N21MSG 9 QT10650N21MSG 129231 9 129271 QT30580N21MSG 9 QT10820U21MS 169090 9 129272 QT30650N21MSG 9 QT10820U21MSG 129228 9 129273 QT30950N21MSG 9 QT10950N21MS 169097 9 129274 QT31100N21MSG 9 QT10950N21MSG 129232 9 129275 QT31400N21MSG 9 QT11100N21MS 169098 9 169000 QT11100N21MSG 129233 9 169075 QT10008U21MS 9 QT11400N21MS 169099 9 169076 QT10017U21MS 9 QT11400N21MSG 129234 9 169077 QT10031U21MS 9 QT20008U21MS 169100 9 The policy of GE is one of 169078 QT10044U21MS 9 QT20017U21MS 169101 9 continuous improvement. 169079 QT10058U21MS 9 QT20031U21MS 169102 9 The right is reserved to alter the 169080 QT10072U21MS 9 QT20044U21MS 169103 9 design or any structural details of 169081 QT10085U21MS 9 QT20058U21MS 169104 9 169082 QT10105U21MS 9 QT20072U21MS 169105 9 the products at any time without 169083 QT10145U21MS 9 QT20085U21MS 169106 9 giving notice. 169084 QT10170U21MS 9 QT20105U21MS 169107 9 169085 QT10210U21MS 9 QT20145U21MS 169108 9 May 2013 169086 QT10310U21MS 9 QT20170U21MS 169109 9 GE Industrial Solutions 169087 QT10390U21MS 9 QT20210U21MS 169110 9 28 Numerical index GE Industrial Solutions GE Industrial Solutions is a fi rst class global supplier of low and medium voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company’s products comes from wholesalers, installers, panelboard builders, contractors, OEMs and utilities worldwide. www.ge.com/ex/industrialsolutions www.ge.com/uk/industrialsolutions Belgium Italy Russia GE Industrial Belgium GE Industrial Solutions GE Industrial Solutions Nieuwevaart 51 Centro Direzionale Colleoni 27/8, Electrozavodskaya street B-9000 Gent Via Paracelso 16 Moscow, 107023 Tel. +32 (0)9 265 21 11 Palazzo Andromeda B1 Tel. +7 495 937 11 11 I-20864 Agrate Brianza (MB) Finland Tel. +39 039 637 3701 South Africa GE Industrial Solutions GE Industrial Solutions Kuortaneenkatu 2 Netherlands Unit 4, 130 Gazelle Avenue FI-00510 Helsinki GE Industrial Solutions Corporate Park Midrand 1685 Tel. +358 (0)10 394 3760 Parallelweg 10 P.O. Box 76672 Wendywood 2144 Nl-7482 CA Haaksbergen Tel. +27 11 238 3000 France Tel. +31 (0)53 573 03 03 GE Industrial Solutions Spain Paris Nord 2 Poland GE Industrial Solutions 13, rue de la Perdrix GE Power Controls P.I. Clot del Tufau, s/n F-95958 Roissy CDG Cédex Ul. Odrowaza 15 E-08295 Sant Vicenç de Castellet Tel. +33 (0)800 912 816 03-310 Warszawa Tel. +34 900 993 625 Tel. +48 22 519 76 00 Germany United Arab Emirates GE Industrial Solutions Ul. Leszczyńska 6 GE Industrial Solutions Robert-Bosch Str. 2a 43-300 Bielsko-Biała Injaz Building, 3rd Floor D-50354 Hürth-Efferen Tel. +48 33 828 62 33 Dubai Internet City Tel. +49 (0) 2233/ 9719-0 PO Box 11549, Dubai Portugal Tel. +971 4 4546912 Hungary GE Industrial Solutions GE Hungary Kft. Rua Camilo Castelo Branco, 805 United Kingdom Vaci ut 81-83. Apartado 2770 GE Industrial Solutions H-1139 Budapest P-4401-601 Vila Nova de Gaia 2 The Arena, Downshire Way Tel. +36 1 447 6050 Tel. +351 22 374 60 00 Bracknell, Berkshire. RG12 1PU Tel. +44 (0)800 587 1239 GE imagination at work 680855 Ref. C/4694/E/EX 4.0 Ed. 05/13 © Copyright GE Industrial Solutions 2013 108781

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the ASTAT?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

General Electric ASTAT XT Series Digital Soft Starters | for 3PH Standard Induction Motors