Industrial Trading chervon right Manufacturers chervon right G chervon right GENERAL ELECTRIC chervon right 269Plus
About product Features Datasheet FAQ

GENERAL ELECTRIC 269Plus

Image of GENERAL ELECTRIC 269Plus

Description

General Electric GE Industrial 269Plus Series Motor Management Relays

Part Number

269Plus

Price

Request Quote

Manufacturer

GENERAL ELECTRIC

Lead Time

Request Quote

Category

Motor Management Relay

Features

Datasheet

pdf file

GE-Industrial-Systems-269Plus-Motor-Management-Relay-datasheet1-1312974863.pdf

155 KiB

Extracted Text

1 INTRODUCTION ORDER CODE / INFORMATION 1.4 ORDER CODE / INFORMATION 1 269/269Plus ****** 269/269Plus Motor management relay SV Standard version D/O Drawout version 1 Phase CT Ground CT (required for D/O only) 1 :5 2000:1 2 :5 :5 3 :1 2000:1 4 :1 :5 2 Relay Failsafe Code (required for D/O only) Trip Alarm Aux1 Aux 2 1 FS NFS NFS FS 2 NFS FS NFS FS 3 FS FS NFS FS 4 NFS NFS FS FS 5 FS NFS FS FS 6 NFS FS FS FS 7 FS FS FS FS 8 NFS NFS NFS FS 3 Relay contact arrangement (required for D/O only) Alarm Aux1 Aux2 1 N.O. N.O. N.O. 2 N.O. N.O. N.C. 3 N.O. N.C. N.O. 4 N.O. N.C. N.C. 5 N.C. N.O. N.O. 6 N.C. N.O. N.C. 7 N.C. N.C. N.O. 8 N.C. N.C. N.C. 100P 100 Ohm Platinum RTD 10C 10 Ohm Copper RTD 100N 100 Ohm Nickel RTD 120N 120 Ohm Nickel RTD HI 90 to 300 V DC / 80 to 265 V AC control voltage 20 to 60 V DC / 20 to 48 V AC control voltage LO 1. For CT ratings greater than 1500:5, consult the factory . . 2. FS = Fail safe: A fail safe relay is one that changes state when control power is applied to the 269/269Plus. NFS = Non fail safe: A non fail safe relay is one that remains on its shelf state when control power is applied to the 269/269Plus. 3. N.O. and N.C. are defined as open and closed contacts of an output relay with control power applied to the 269/269Plus and no trips or alarms present. EXAMPLE: For a 269Plus with options: 269PLUS-SV-100P-HI For a 269 Drawout with options: 269-D/O-3-4-7-100P-HI The 269 Plus relay is almost entirely field programmable. The information shown above must be specified when the relay is ordered, as these options are not selectable in the field. Additional features can be made available on special order by contacting GE Multilin. * CT information, failsafe code, and contact arrangement must be specified for drawout relays only; on standard 269 Plus models these features are field selectable. ** See Glossary for definitions GE Multilin 269 Plus Motor Management Relay 1-5 TECHNICAL SPECIFICATIONS 1 INTRODUCTION 1.5 TECHNICAL SPECIFICATIONS 1 PHASE CURRENT INPUTS TRIP/ALARM DELAY TIME ACCURACY conversion: calibrated RMS, sample time 2 ms short circuit trip: instantaneous: 15 to 45 ms delayed: ±1.5 seconds range: 0.05 to 12 × phase CT primary amps setpoint ground fault: instantaneous: 15 to 45 ms delayed 0.5 sec.: ±150 ms full scale: 12 × phase CT primary amps set- delayed over 1 sec.: ±1 s or ±2.5% point of total trip time accuracy: ±0.5% of full scale acceleration trip: ±200 ms or ±2% of total trip time (0.05 to 2 × phase CT primary amps setpoint) single phasing: ±1.5 seconds ±1.0% of full scale immediate overload: 0.3 to 0.7 seconds (over 2 × phase CT primary amps mechanical jam: ±1.5 seconds setpoint) rapid trip: ±1.0 seconds Frequency: 25 to 400 Hz sine wave undercurrent: ±1.5 sec. or ±2% of total trip time GROUND FAULT CURRENT INPUT current unbalance: ±1.0 sec. or ±2% of total trip time conversion: calibrated RMS, sample time 2 ms metering: ±6.0 sec. ±2% of total trip time range: 0.1 to 1.0 × G/F CT primary amps RTD INPUTS setpoint (5 A secondary CT) sensor types: 10 Ω copper 0.3 to 10.0 amps 50:0.025 A 100 Ω nickel (2000:1 ratio) 120 Ω nickel full scale: 1 × G/F CT primary amps setpoint 100 Ω platinum (5 A secondary CT) (specified with order) 10 A (2000:1 CT) display accuracy: ± 2°C accuracy: ±4% of G/F CT primary amps set- trip/alarm setpoint point (5 A secondary CT) range: 0 to 200°C ±0.3 A primary (2000:1 CT HGF 3”) dead band: 3°C Frequency: 20 to 400 Hz for 5 A CTs maximum lead 20 to 150 Hz for 2000:1 CTs resistance: 25% of RTD 0°C resistance OVERLOAD CURVES ANALOG CURRENT OUTPUT (4-20 mA STANDARD) curves: 8 curves fixed shape 1 custom curve PROGRAMMABLE trip time accuracy: ±1 sec. up to 13 sec. OUTPUT 0-1 mA 0-20 mA 4-20 mA ±8% of trip time over 13 sec. detection level: ±1% of primary CT amps MAX LOAD 2000 Ω 300 Ω 300 Ω UNBALANCE MAX OUTPUT 1.01 mA 20.2 mA 20.2 mA display accuracy: ±2 percentage points of true nega- tive sequence unbalance (I /I ) n p accuracy: ±1% of full scale reading RUNNING HOURS COUNTER polarity: terminal 58 (“–”) must be at ground accuracy: ±1% potential (i.e. output is not isolated) DIFFERENTIAL RELAY INPUT Isolation: non-isolated, active source relay response time: 100 msec. maximum Update Time: 250 ms max. (contact closure to output relay acti- COMMUNICATIONS vation) Type: RS485 2-wire, half duplex, isolated RELAY LOCK-OUT TIME Baud Rate: 300, 1200, 2400 accuracy: ±1 minute with control power ® Protocol: Subset of Modbus RTU applied Functions: Read/write setpoints (03/16), ±20% of total lock-out time with no Read actual values (03/04) control power applied 1-6 269 Plus Motor Management Relay GE Multilin 1 INTRODUCTION TECHNICAL SPECIFICATIONS RELAY CONTACTS CONTROL POWER (INCLUDES TOLERANCES) Frequency: 50/60 Hz VOLTAGE MAKE/CARRY MAKE/ BREAK 1 LO range: 20 to 60 V DC CONTINUOUS CARRY 0.2s 20 to 48 V AC RESISTIVE 30 VDC 10 30 10 HI range: 90 to 300 V DC 125 VDC 10 30 0.5 80 to 265 V AC 250 VDC 10 30 0.3 Max. power consumption: 20 VA INDUCTIVE 30 VDC Voltage low ride-through time: 100 ms 10 30 5 (L/R=7ms) (at 120 V AC/125 V DC) 125 VDC 10 30 0.25 Relay can be powered from either AC or DC 250 VDC 10 30 0.15 source. If Control Power input exceeds 250 V, an RESISTIVE 120 VAC 10 30 10 external 3 A fuse must be used rated to the NOTE required voltage. 250 VAC 10 30 10 INDUCTIVE 120 VAC INTERNAL FUSE SPECIFICATIONS 10 30 4 PF=0.4 T3.15A H 250 V 250 VAC 10 30 3 Timelag high breaking capacity configuration FORM C NO/NC DIELECTRIC STRENGTH ROUTINE TEST contact material silver alloy 2200 V AC, 50/60 Hz for 1 sec. minimum permissible GROUND (Terminal 42) to load: 5 V DC, 100 mA Output Contacts (Terminals 29 through 40) 12 V AC, 100 mA Control Power (Terminals 41 & 43) Current Transformer Inputs (Terminals 72 SWITCH INPUTS through 83) Type: Dry contacts If Hi-Pot tests are performed, jumper J201 DO NOT CONNECT LIVE CIRCUITS TO THE DIGI- TAL SWITCH INPUTS. THEY ARE DESIGNED FOR beside Terminal 43 should be placed in the “HI- CAUTION DRY CONTACTS ONLY! POT” position. Upon completion of Hi-Pot NOTE tests, the jumper should be placed in the CT BURDEN DUE TO CONNECTION OF RELAY “GND” position. See Figure 5–3: HI-POT TEST- ING on page 5–7. CT INPUT BURDEN (AMPS) To avoid electrical shock, discharge J201 by (VA) (mΩ) shorting across the pins before reconnecting PHASE 10.04 43 WARNING the J201 jumper. CT 40.5 31 (1A) 13 4.8 28 PHASE 50.06 2.4 CT 20 1 2.5 (5A) 65 8.5 2.01 G/F CT 50.08 3 (5A) 10 0.3 3 G/F CT 0.025 0.435 696 Ω (50:0.025) 0.1 3.29 329 Ω 0.5 50 200 Ω CT THERMAL WITHSTAND Phase CT (1A, 5A) & G/F 5A tap: 3 ×: continuous 6 ×: 40 sec. 12 ×: 3 sec. Phase CT 1A & 5A: 40 x: 2 sec. 80 x: 1 sec. G/F 50:0.025 mA: 6 ×: continuous GE Multilin 269 Plus Motor Management Relay 1-7 TECHNICAL SPECIFICATIONS 1 INTRODUCTION TYPE TESTS PACKAGING Dielectric Strength: 2.0 kV for 1 minute to relays, CTs, Shipping box: 11.40" x 7.50" x 16.00" (W × H × D) power supply 1 290 mm x 190 mm x 410 mm Insulation Resistance: IEC255-5,500 V DC (W × H × D) Transients: ANSI C37.90.1 Oscillatory 2.5kV/ Ship weight: 3.5 kg 1MHz 7.75 lb. ANSI C37.90.1 Fast Rise 5kV/10ns 269 Plus drawout: Ontario Hydro A-28M-82 Shipping box: 13.25" x 12.50" x 20.50" (L × H × D) IEC255-4 Impulse/High 340 mm x 320 mm x 520 mm Frequency Disturbance Ship weight: 12 kg 26.4 lb. Class III Level Impulse Test: IEC 255-5 0.5 Joule 5kV CERTIFICATIONS RFI: 50 MHz/15W Transmitter ISO: Manufactured to an ISO9001 certi- fied program EMI: C37.90.2 Electromagnetic Interfer- UL: UL recognized (file E83849) ence @ 150 MHz and 450 MHz, 10V/m UL 508 Industrial Control Equipment. Static: IEC 801-2 Static Discharge UL1053 - Ground Fault Protection Humidity: 95% non- condensing Equipment. Temperature: -25°C to +60°C ambient CSA: Certified per C22.2 No.14 - Environment: IEC 68-2-38 Temperature/Humidity Industrial Control Equipment Cycle CE: Conforms to IEC 947-1, IEC 1010-1 Dust/Moisture: NEMA 12/IP53 with proper installa- Overvoltage Category:II tion Pollution Degree: 2 Altitude Rating: 2000m IEC 1010-1 IP Code: 40X OPERATING AMBIENT TEMPERATURE The 269 Plus Drawout does not meet CE compliance. & STORAGE TEMPERATURE –25°C to +60°C HAZARD may result if the product is not used for intended purposes. WARNING This equipment can only be serviced by trained personnel. WARNING Relay contacts must be considered unsafe to touch when the system is energized! WARNING 1-8 269 Plus Motor Management Relay GE Multilin 1 INTRODUCTION MPM OPTION SPECIFICATIONS 1.6 MPM OPTION SPECIFICATIONS 1 PHASE CURRENT INPUTS TYPE TESTS Conversion: true rms, 64 samples/cycle Dielectric strength: 2.0 kV for 1 minute to relays, CTs, VTs, power supply CT input: 1A and 5A secondary Insulation resistance: IEC255-5, 500 V DC Burden: 0.2 VA Transients: ANSI C37.90.1 Oscillatory 2.5 kV/ Overload: 20 x CT for 1 s, 1MHz 100 x CT for 0.2 s ANSI C37.90.1 Fast Rise 5 kV/10 ns Range: 1 to 150% of CT primary nd Ontario Hydro A-28M-82 Frequency: up to 32 harmonic IEC255-4 Impulse/High Accuracy: ±1% of display Frequency Disturbance VOLTAGE INPUTS Class III Level Conversion: true rms, 64 samples/cycle Impulse test: IEC 255-5 0.5 Joule 5 kV VT pri/Sec: direct or 120 to 72000:69 to 240 RFI: 50 MHz/15 W Transmitter Input range: 20 to 600 V AC EMI: C37.90.2 Electromagnetic Interfer- Full scale: 150/600 V AC autoscaled ence @ 150 MHz and 450 MHz, nd Frequency: up to 32 harmonic 10V/m Accuracy: ±1% of display Static: IEC 801-2 Static Discharge ANALOG OUTPUTS Humidity: 95% non-condensing Temperature: –10°C to +60°C ambient OUTPUT Environment: IEC 68-2-38 Temperature/Humidity Cycle 0-1 mA 4-20 mA (T1 option) (T20 option) Dust/moisture: NEMA 12/IP53 MAX LOAD 2400 Ω 600 Ω PACKAGING Shipping box: 8½" × 6" × 6" (L × H × D) MAX OUTPUT 1.1 mA 21 mA 215 cm × 152 cm × 152 cm (L×H×D) Accuracy: ±2% of full scale reading Ship weight: 5 lbs/2.3 kg Isolation: 50 V isolated, activesource CERTIFICATION MEASURED VALUES ISO: Manufactured to an ISO9001 certi- fied program PARAME- ACCURACY RESOLU- RANGE UL: UL listed (file E83849) TER % DISPLAY TION UL 508 - Industrial Control Voltage ±1% 1 V 20 to 100% of Equipment. VT UL1053 - Ground Fault Protection Current ±1% 1 A 1 to 150% of CT Equipment. CSA: Certified per C22.2 No.14 - kW ±2% 1 kW 0 to 65535 kW Industrial Control Equipment kvar ±2% 1 kvar 0 to 65535 kvar It is recommended that all relays be pow- PF ±2% 0.01 ±0.00 to 1.00 ered up at least once per year to avoid Frequency ±0.2% 0.1 Hz 20.00 to 70.00 NOTE deterioration of electrolytic capacitors in Hz the power supply. CONTROL POWER Input: 90 to 300 V DC or 70 to 265 V AC, 50/60 Hz Power: nominal 10 VA maximum 20 VA Holdup: 100 ms typical (@ 120 V AC/125 V DC) GE Multilin 269 Plus Motor Management Relay 1-9

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the 269Plus?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

General Electric 269P100PHI Motor Management Relay