FOXBORO P0916NG

Image of FOXBORO P0916NG

Description

TERMINATION ASSEMBLY FBM242 2TIER COMPRESSION

Part Number

P0916NG

Price

Request Quote

Manufacturer

FOXBORO

Lead Time

Request Quote

Category

None

Specifications

Applied voltage

15 to 60VDC (maximum)

Calibration requirements

The module and termination assemblies require no calibration. Each channel is galvanically isolated from all other channels and earth (ground). The module withstands, without damage, a potential of 600VAC applied for one minute between any channel and ground, or between a given channel and any other channel.

Communication

Communicates with its associated FCM or FCP via the redundant 2Mbps module fieldbus

Foxboro

P0916NG

Inductive loads

Module output may require a protective diode or metal oxide varistor (MOV) connected across the inductive load.

Load current

2.25A (maximum) per channel

Load current-In-Rush

8 A (maximum) for 20 ms per channel at 30°C and 6.4 A (maximum) for 20 ms per channel at 70°C.

Off-state leakage current

0.1 mA (maximum)

On-state voltage Drop

0.2V (maximum) at 2.25A

Output channels

Sixteen isolated channels

Power requirements

Input voltage range (redundant) 24VDC +5%, -10% consumption (maximum)

Features

Datasheet

pdf file

Foxboro=-P0916NG=datasheet1-1161259978.pdf

1477 KiB

Extracted Text

® I/A Series HARDWARE Product Specifications PSS 21H-2Z42 B4 FBM242, Externally Sourced, Discrete Output Interface Module The FBM242 Discrete Output Interface Module contains 16 discrete output channels which are sourced externally.  Executes the Discrete I/O or Ladder Logic FEATURES program, with the following configurable options: Key features of the FBM242 modules are: Input Filter Time, Fail Safe Configuration, Fail-  Sixteen discrete outputs Safe Fall-Back, and Sustained or Momentary  Supports discrete output signals at voltages of: Outputs  Various Termination Assemblies (TAs) that • 15 to 60 V dc contain: 120 V ac/125 V dc Current limiting devices 240 V ac Fuses  Each input and output is galvanically isolated; Relay outputs with external power source, group isolated when used with external excitation fusing, and power distribution  Compact, rugged design suitable for enclosure in Solid state outputs Class G3 (harsh) environments Redundant power distribution Foxboro PSS 21H-2Z42 B4 Page 2 OVERVIEW FIELDBUS COMMUNICATION The FBM242 Discrete Output Interface Module A Fieldbus Communications Module or a Control contains 16 discrete output channels, which are Processor interfaces to the redundant 2 Mbps sourced externally, rated up to 2 A at 60 V dc. module Fieldbus used by the FBMs. The FBM242 Associated termination assemblies (TAs) provide for accepts communication from either path (A or B) of discrete outputs to loads of 2 A at 60 V dc, relay the redundant 2 Mbps Fieldbus — should one path outputs (120 V ac/125 V dc, or 240 V ac), or relay fail or be switched at the system level, the module outputs with power distribution and fusing. Each continues communication over the active path. output is fully isolated from other channels and ground. SECURITY Field power for contacts or solid state switches is The module interfaces electrical output signals from a current limited. control processor to the field devices. It executes a digital I/O application program, with ladder logic MODULAR BASEPLATE MOUNTING support, and provides a Fail-Safe Configuration option for the outputs. The module mounts on a DIN rail mounted Modular baseplate, which accommodates up to four or eight COMPACT DESIGN Fieldbus Modules. The Modular baseplate is either DIN rail mounted or rack mounted, and includes The module has a compact design, with a rugged signal connectors for redundant Fieldbus, redundant extruded aluminum exterior for physical protection of independent dc power, and termination cables. the circuits. Enclosures specially designed for mounting the FBMs provide various levels of TERMINATION ASSEMBLIES (TAs) environmental protection, up to harsh environments (Class G3), per ISA Standard S71.04. Field I/O signals connect to the FBM subsystem via DIN rail mounted TAs. The TAs used with the VISUAL INDICATORS FBM242 are described in “TERMINATION ASSEMBLIES” on page 8. Light-emitting diodes (LEDs) incorporated into the front of the module provide visual indication of the module operational status, as well as the discrete states of the individual output points. EASY REMOVAL/REPLACEMENT The module can be removed/replaced without removing field device termination cabling, power, or communication cabling. PSS 21H-2Z42 B4 Page 3 FUNCTIONAL SPECIFICATIONS Output Channels Communication Sixteen isolated channels. Communicates with its associated FCM or FCP via the redundant 2 Mbps module Fieldbus Applied Voltage 15 to 60 V dc (maximum) Power Requirements INPUT VOLTAGE RANGE (REDUNDANT) Load Current 24 V dc +5%, -10% 2.25 A (maximum) per channel CONSUMPTION (MAXIMUM) Load Current-In-Rush 3 W (maximum) at 24 V dc 8 A (maximum) for 20 ms per channel at 30°C. HEAT DISSIPATION (MAXIMUM) 6.4 A (maximum) for 20 ms per channel at 70°C. 6.5 W (maximum) at 24 V dc (with all outputs at On-State Voltage Drop 1.5 A each) 0.2 V (maximum) at 2.25 A Calibration Requirements Off-State Leakage Current The module and termination assemblies require no 0.1 mA (maximum) calibration. Inductive Loads Module output may require a protective diode or metal oxide varistor (MOV) connected across the inductive load. Output Channel Isolation Each channel is galvanically isolated from all other channels and earth (ground). The module withstands, without damage, a potential of 600 V ac applied for one minute between any channel and ground, or between a given channel and any other channel. CAUTION This does not imply that these channels are intended for permanent connection to voltages of these levels. Exceeding the limits for input voltages, as stated elsewhere in this specification, violates electrical safety codes and may expose users to electric shock. PSS 21H-2Z42 B4 Page 4 FUNCTIONAL SPECIFICATIONS (CONTINUED) Subsystem User’s Guide (B0400FA). Regulatory Compliance Communications circuits also meet the ELECTROMAGNETIC COMPATIBILITY (EMC) requirements for Class 2 as defined in Article European EMC Directive 89/336/EEC 725 of the National Electrical Code (NFPA Meets: EN 50081-2 Emission standard No.70) and Section 16 of the Canadian EN 50082-2 Immunity standard Electrical Code (CSA C22.1). Conditions for EN 61326 Annex A (Industrial Levels) use are as specified in the I/A Series DIN Rail CISPR 11, Industrial Scientific and Medical Mounted Subsystem User’s Guide (ISM) Radio-frequency Equipment - (B0400FA). Electromagnetic Disturbance Characteristics European Low Voltage Directive 73/23/EEC - Limits and Methods of Measurement and Explosive Atmospheres (ATEX) directive Meets: Class A Limits 94/9/EC IEC 61000-4-2 ESD Immunity CENELEC (DEMKO) certified as Contact 4 kV, air 8 kV EEx nA IIC T4 for use in CENELEC certified IEC 61000-4-3 Radiated Field Immunity Zone 2 enclosure certified as associated 10 V/m at 80 to 1000 MHz apparatus for supplying non-incendive field IEC 61000-4-4 Electrical Fast circuits for Zone 2, Group IIC, potentially Transient/Burst Immunity explosive atmospheres when connected to 2 kV on I/O, V dc power and communication specified I/A Series processor modules as lines described in the I/A Series DIN Rail Mounted IEC 61000-4-5 Surge Immunity Subsystem User’s Guide (B0400FA). Also 2kV on ac and dc power lines; 1kV on I/O see, “Certifications for Termination and communications lines Assemblies” on page 11. IEC 61000-4-6 Immunity to Conducted PRODUCT SAFETY - TERMINATION Disturbances induced by Radio-frequency ASSEMBLIES WITH RELAY OUTPUTS OR Fields HIGH VOLTAGE INPUTS 10 V (rms) at 150 kHz to 80 MHz on I/O, V Underwriters Laboratories (UL) for U.S. and dc power and communication lines Canada IEC 61000-4-8 Power Frequency Magnetic UL/UL-C listed as suitable for use in ordinary Field Immunity locations and compliant with UL 3121, First 30 A/m at 50 and 60 Hz Edition, and Canadian Standard, C22.2 PRODUCT SAFETY - TERMINATION No.1010.1-92 when connected to specified ASSEMBLIES WITH LOW VOLTAGE INPUTS I/A Series processor modules as described Underwriters Laboratories (UL) for U.S. and in the I/A Series DIN Rail Mounted Canada Subsystem User’s Guide (B0400FA). UL/UL-C listed as suitable for use in European Low Voltage Directive 73/23/EEC UL/UL-C listed Class I, Groups A-D; Certified for use in ordinary locations and Division 2; temperature code T4 enclosure compliant with IEC 61010 when connected based systems. These modules are also UL to specified I/A Series processor modules as and UL-C listed as associated apparatus for described in the I/A Series DIN Rail Mounted supplying non-incendive communication Subsystem User’s Guide (B0400FA) circuits for Class I, Groups A-D hazardous locations when connected to specified ® I/A Series processor modules as described in the I/A Series DIN Rail Mounted PSS 21H-2Z42 B4 Page 5 (1) ENVIRONMENTAL SPECIFICATIONS Operating Conditions Storage Conditions TEMPERATURE TEMPERATURE -40 to +70°C (-40 to +158°F) Module -20 to +70°C (-4 to +158°F) RELATIVE HUMIDITY Termination Assembly 5 to 95% (noncondensing) PVC ALTITUDE -20 to +50°C (-4 to +122°F) -300 to +12 000 m (-1000 to +40 000 ft) PA Contamination -20 to +70°C (-4 to +158°F) Suitable for use in Class G3 (Harsh) environments as RELATIVE HUMIDITY defined in ISA Standard S71.04, based on exposure 5 to 95% (noncondensing testing according to EIA Standard 364-65, Class III. ALTITUDE Vibration -300 to +3000 m (-1000 to +10 000 ft) 2 7.5 m/s (5 to 500 Hz) (1) The environment ranges can be extended by the type of enclosure containing the module. Refer to the Product Specification Sheet (PSS) applicable to the enclosure that is to be used. PSS 21H-2Z42 B4 Page 6 PHYSICAL SPECIFICATIONS Mounting Dimensions - Module MODULE HEIGHT FBM242 mounts on a Modular Baseplate. The 102 mm (4 in),114 mm (4.5 in) including mounting baseplate can be mounted on a DIN rail lugs (horizontally or vertically), or horizontally on a WIDTH 19-inch rack using a mounting kit. Refer to 45 mm (1.75 in) PSS 21H-2W6 B4 for details. DEPTH TERMINATION ASSEMBLY 104 mm (4.11 in) The TA mounts on a DIN rail and accommodates Dimensions - Termination Assembly multiple DIN rail styles including 32 mm (1.26 in) COMPRESSION SCREW and 35 mm 1.38 in) Refer to page 13 Mass RING LUG AND KNIFE SWITCH MODULE Refer to page 15 284 g (10 oz) approximate Termination Cables TERMINATION ASSEMBLY CABLE LENGTHS Compression Up to 30 m (98 ft) 127 mm (5.02 in) – 272 g (0.60 lb, CABLE MATERIALS approximate) ® Polyurethane or Hypalon /XLP. 148 mm (5.75 in) – 285 g (0.65 lb, approximate) TERMINATION CABLE TYPE 216 mm (8.51 in) – 320 g (0.70 lb, Type 4 or type 4H - Refer to Table 1 approximate) CABLE CONNECTION Ring Lug 37-pin male D-subminiature 196 mm (7.78 in) – 310 g (0.68 lb, Construction - Termination Assembly approximate MATERIAL 321mm (12.64 in) – 600 g (1.6 lb, Polypropylene (PVC), compression approximate Polyamide (PA), compression Part Numbers PVC, ring lug MODULE PVC, knife terminal P0916TA FAMILY GROUP COLOR TERMINATION ASSEMBLIES Dark blue - discrete Refer to “FUNCTIONAL SPECIFICATIONS - TERMINAL BLOCKS TERMINATION ASSEMBLIES” on page 9 Outputs- 2 tiers (switch and solid state), 3 tiers (relay), 16 positions Power Distribution - 2 tiers, 4 positions PSS 21H-2Z42 B4 Page 7 PHYSICAL SPECIFICATIONS (CONTINUED) Field Termination Connections Termination Assembly Switching Relays COMPRESSION - ACCEPTED WIRING SIZES ELECTRICAL SERVICE LIFE 100,000 operations at rated resistive load Solid/Stranded/AWG 2 2 5,000,000 operations at no load. 0.2 to 4 mm /0.2 to 2.5 mm /24 to 12 AWG 5 A RELAY Stranded with Ferrules 2 Type 0.2 to 2.5 mm with or without plastic collar Single-Pole, Double-Throw, Normally Open RING-LUG - ACCEPTED WIRING SIZES (SPDT_NO) #6 size connectors (0.375 in (9.5 mm)) 2 Switching Current 0.5 to 4 mm /22 AWG to 12 AWG 5 A at up to 120 V ac (see “GENERAL PURPOSE PLUG-IN RELAY TERMINATION ASSEMBLY SPECIFICATIONS” on page 16) PSS 21H-2Z42 B4 Page 8 (fusing). Termination assemblies with protection have TERMINATION ASSEMBLIES individual user serviceable fuses that are designed to General Description limit the output current to 2 A. Sixteen vertically Field I/O signals connect to the FBM subsystem via mounted, one per channel, 3.15 A sand filled fuses DIN rail mounted termination assemblies (TAs). (temperature derated) allow a maximum of 2 A Multiple types of TAs are available with FBMs to current per output channel. Termination assemblies provide I/O signal connections, signal conditioning, without fusing (unprotected) are intended for use by optical isolation from signal surges, external power Foxboro engineers or customers who are using connections, and/or fusing for protection of the FBM interposing relays or fuse terminal blocks between and/or field device as required by the particular FBM. the termination assembly and the field devices. Since these features are built into the termination Power for the low voltage outputs can be supplied by assemblies (where required), in most applications the FBM +24 V dc auxiliary power supply (internally there is no need for additional termination equipment (FBM) sourced) or by a field voltage source (externally for field circuit functions such as circuit protection or sourced). signal conditioning (including fusing and power High Voltage Discrete Outputs distribution). The high voltage output (120 V ac or 240 V ac) The DIN rail mounted termination assemblies termination assemblies use plug-in SPDT (Form C) connect to the FBM subsystem baseplate by means electromechanical relays and solid-state switches. of removable termination cables. The cables are The plug-in sockets allow field replacement of available in a variety of lengths, up to 30 meters individual relays. The relays and associated sockets (98 feet), allowing the termination assemblies to be are located under the component covers of the mounted in either the enclosure or in an adjacent termination assemblies.The termination assembly’s enclosure. Refer to “FUNCTIONAL SPECIFICATIONS switched outputs use unsealed, general purpose - TERMINATION ASSEMBLIES” on page 9 for relays.These assemblies are capable of providing termination cable part numbers and specifications. mixed voltage and are designed to provide signal segregation by locating the low voltage inputs an the Discrete Outputs opposite side of the terminal assembly from the Termination assemblies with discrete outputs support outputs. A solid-state output module is optionally sixteen 2-wire discrete output signals at passive low available. High voltage discrete outputs are always voltages of less than 60 V dc and active high voltage externally sourced power. levels of 120 V ac or 240 V ac. Active termination The output termination assemblies come in either assemblies support output signal conditioning for output or output with power distribution (user- FBMs. To condition signals, these termination supplied via terminals on the termination assembly). assemblies provide fuse protection, relays, solid-state In both configurations, when the FBM output is on, devices, and terminal blocks to connect externally the relay coil is energized and the relay contact is supplied optional power distribution. switched from normally closed (NC) position to the Low Voltage Discrete Outputs normally open (NO) position. The FBM +24 V dc The low voltage outputs (less than 60 V dc) use auxiliary power supply is used to energize the relay passive termination assemblies. These assemblies coil. are available with and without output protection PSS 21H-2Z42 B4 Page 9 Termination assemblies with power distribution have a dedicated terminal block which provides a connection to externally supplied power and distributed internally on the termination assembly to each of the output channels. The line or positive side of the supply is fused; the neutral or negative side of the supply is connected to the field. FUNCTIONAL SPECIFICATIONS - TERMINATION ASSEMBLIES (b) TA Part Number TA TA FBM Term. Cable Certification (a) (c) (d) (e) Type Output Signal PVC PA Type Type Type FBM242 16 channel, switch (protected - fused) P0916JY C 4, 4H 1,2 15 to 60 V dc (externally sourced) at 2 A P0916RJ RL maximum Channel isolation provided by FBM242 FBM242 16 channel, switch (unprotected - no P0917XX C 4, 4H 1,2 fuses) 15 to 60 V dc (externally sourced) at 2 A maximum Channel isolation provided by FBM242 FBM242 16 channel, switch (protected - fused) P0917HX C 4, 4H 1,4 15 to 60 V dc (externally sourced) at 2 A maximum with power distribution Current is limited to 12A maximum for each group of 8 channels simultaneously Group isolation provided by termination assembly (f) FBM242 16 channel, switch (each channel is P0923LH C4, 4H 1,4 protected - fused) Redundant power 15 to 60 V dc (externally sourced) at 12 A maximum with power distribution Group isolation provided by termination assembly FBM242 16 channel, switch (externally sourced) P0923LL C 4 5 SPDT (Form C) Relays with LED indicators <30 V dc at 5 A maximum, Up to 250 V ac at 5 A maximum Channel isolation provided by termination assembly relays PSS 21H-2Z42 B4 Page 10 FUNCTIONAL SPECIFICATIONS - TERMINATION ASSEMBLIES (CONTINUED) (b) TA Part Number TA TA FBM Term. Cable Certification (a) (c) (d) (e) Type Output Signal PVC PA Type Type Type FBM242 16 channel, switch (externally sourced) P0916NG P0916YY C 45 SPDT (Form C) Relays P0916RK RL <30 V dc at 5 A maximum, Up to 250 V ac at 5 A maximum Channel Isolation provided by termination assembly relays FBM242 16 channel, switch (externally sourced) P0916JZ P0916YZ C 4 5 with power distribution P0916RL RL SPDT (Form C) Relays <30 V dc at 5 A maximum Up to 250 V ac at 5 A maximum Total current is limited to 12 A maximum for each group of 8 channels simultaneously Group isolation provided by termination assembly (g) FBM242 16 channel, switch (externally sourced) P0926DV Knife 45 SPDT (Form C) Relays 125 V ac/125V dc at 2 A maximum Channel isolation provided by termination assembly relays (g) FBM242 16 channel, switch (externally sourced) P0926BE Knife 4 5 Solid State Switch 125 V ac/125V dc at 2 A maximum Channel isolation provided by FBM242 (a) Maximum current is limited to12 A per 8 channels. Output inductive load limits based on current of 2 A. Inductance limit increases by a factor of 4, for each factor of 2 reduction in current. For an inductive load above stated limits, a snubber diode is required for a dc inductive load or a MOV (metal oxide varistor) is required for an ac inductive load. Diode current rating must be equal to the maximum load current and voltage rating equal to 1.3X maximum supply voltage. MOV must be rated for 120 V ac use and current rating must be equal to maximum load current. (b) PVC is polyvinyl chloride rated from -20 to +50°C (-4 to 122°F); PA is polyamide rated from -20 to +70°C (-4 to +158°F). (c) C = TA with compression terminals, RL = TA with ring lug terminals. Knife has compression terminals. (d) See to Table 2 and Table 3 for cable part numbers. (e) See to Table 1 Termination Assembly certification definitions. (f) The “ON” volt drop for an FBM242 across the Oring diode is typically: 0.498V @ 12A; 0.520V @16 A. The typical voltage drop to a channel output is 0.6V at 1.65A per channel. (g) This is knife disconnect construction. Knives and test sockets provided for circuit validation only. Knife disconnects are not rated for interrupting loads. Power must be removed before disconnecting circuit. PSS 21H-2Z42 B4 Page 11 Table 1. Certifications for Termination Assemblies Type Certification Type 1 TAs are UL/UL-C listed as suitable for use in Class I; Groups A-D; Division 2 temperature code T4 hazardous locations. They are CENELEC (DEMKO) certified EEx nA IIC T4 for use in Zone 2 potentially explosive atmospheres. Type 2 TAs are UL/UL-C listed as associated apparatus for supplying non-incendive field circuits Class I; Groups A-D; Division 2 hazardous locations when connected to specified DIN rail mounted FBMs and field circuits meeting entity parameter constraints specified in DIN Rail Mounted Subsystem User’s Guide (B0400FA). They are also CENELEC (DEMKO) certified as associated apparatus for supplying field circuits for Group IIC, Zone 2 potentially explosive atmospheres. Field circuits are also Class 2 limited energy (60 V dc, 30 V ac, 100 VA or less) if customer- supplied equipment meets Class 2 Type 4 All field circuits are Class 2 limited energy (60 V dc, 30 V ac, 100 VA or less) if customer-supplied equipment meets Class 2 limits. Type 5 The TA and its field circuitry are for use in only ordinary (non-hazardous) locations. Table 2. P/PVC Cable Types and Part Numbers Length Type 4, Type 4H, Length Type 4, Type 4H, (b) (a)(b) (b) (a)(b) m (ft) 26 AWG 22 AWG m (ft) 26 AWG 22 AWG 0.5 (1.6) P0916FG 10.0 (32.8) P0916FL P0916GE 1.0 (3.2) P0916FH 15.0 (49.2) P0916FM P0916GF 2.0 (6.6) P0931RQ 20.0 (65.6) P0916FN P0916GG 3.0 (9.8) P0916FJ 25.0 (82.0) P0916FP P0916GH 5.0 (16.4) P0916FK 30.0 (98.4) P0916FQ P0916GJ (a) Type 4H cables are used to reduce voltage drop in long (greater than 5 m (15 ft)) cable run applications. (b) Type 4 and Type 4H cables are not interchangeable. P/PVC is polyurethane outer jacket and semi-rigid PVC primary conductor insulation. Temperature range; -20 to +80°C (-4 to +176°F) PSS 21H-2Z42 B4 Page 12 Table 3. Hypalon/XLPE Cable Types and Part Numbers Length Type 4, Type 4H, Length Type 4, Type 4H, (b) (a)(b) (b) (a)(b) m (ft) 26 AWG 22 AWG m (ft) 26 AWG 22 AWG 0.5 (1.6) P0916WD 10.0 (32.8) P0916WH P0916WN 1.0 (3.2) P0916WE 15.0 (49.2) P0916WJ P0916WP 2.0 (6.6) P0931RU 20.0 (65.6) P0916WK P0916WQ 3.0 (9.8) P0916WF 25.0 (82.0) P0916WL P0916WR 5.0 (16.4) P0916WG 30.0 (98.4) P0916WM P0916WS (a) Type 4H cables are used to reduce voltage drop in long (greater than 5 m (15 ft)) cable run applications. (b) Type 4 and Type 4H cables are not interchangeable. H/XLPE is Hypalon outer jacket and XLPE (cross-linked polyethylene) primary conductor insulation. Temperature range; -40 to +90°C (-40 to +194°F). PSS 21H-2Z42 B4 Page 13 DIMENSIONS – NOMINAL Compression Termination Assemblies P0917XX, P0916JY [125] [127] (a) 4.93 5.02 [72] (b) [80] 2.83 3.13 P0917HX [125] [146] (a) 4.93 5.75 [72] (b) [80] 2.83 3.13 P0916JZ, P0916YZ [125] [216] (a) 4.93 8.51 [74] (b) [80] 2.93 3.13 1 P0916NG, P0916YY, P0923LL [125] [216] (a) 4.93 8.51 [72] (b) [80] 2.83 3.13 (a) Overall width – for determining DIN rail loading. (b) Height above DIN rail (add to DIN rail height for total). 1 Dimensions shown are for the PVC versions. All dimensions for this polyamide termination assembly are smaller. PSS 21H-2Z42 B4 Page 14 DIMENSIONS – NOMINAL (CONTINUED) Compression Termination Assemblies (Continued) P0923LH     D    E  Ring Lug and Knife Switch Termination Assemblies P0916RJ [125] [198] (a) 7.78 4.93 [72] (b) 2.83 [80] 3.13 P0916RL [321] (a) [125] 12.64 4.93 [74] (b) [80] 2.93 3.13 P0916RK [125] [321] (a) 4.93 12.64 [72] (b) [80] 2.83 3.13 (a) Overall width – for determining DIN rail loading. (b) Height above DIN rail (add to DIN rail height for total). PSS 21H-2Z42 B4 Page 15 DIMENSIONS – NOMINAL (CONTINUED) Ring Lug and Knife Switch Termination Assemblies (Continued) P0926BE [321] (a) [125] 12.64 4.93 [72] (b) [80] 2.83 3.13 P0926DV 373 125 4.93 14.67 72 80 2.83 3.14 (a) Overall width – for determining DIN rail loading. (b) Height above DIN rail (add to DIN rail height for total). PSS 21H-2Z42 B4 Page 16 GENERAL PURPOSE PLUG-IN RELAY TERMINATION ASSEMBLY SPECIFICATIONS Description Minimum Permissible Load SPDT, plug-in, field replaceable 100 mA, 5 V dc Rated Load Contact Material AgCdO dc RESISTIVE 5 A at 30 V dc Contact Resistance dc INDUCTIVE (L/R = 7 MS) 30 m Ω maximum 5 A at 30 V dc Life Expectancy ac RESISTIVE MECHANICAL 5 A at 240 V ac 6 20 X 10 operations minimum ac INDUCTIVE (P.F. = 0.4) ELECTRICAL 5 A at 240 V ac 3 100 X10 (at rated load) Carry Current Response Time 5 A OPERATE Maximum Operating Voltage 15 ms maximum 240 V ac, 30 V dc RELEASE Maximum Operating Current ac 5 A 10 ms maximum dc Maximum Switching Capacity 5 ms maximum 1200 VA, 150 W RELATED PRODUCT SPECIFICATION SHEETS (PSS) PSS Number Description PSS 21H-2W1 B3 DIN Rail Mounted FBM Subsystem Overview PSS 21H-2W2 B3 DIN Rail Mounted FBM Equipment, Agency Certification PSS 21S-3B2 B3 Control Processor 270 (CP270) Integrated Control Software IPS Corporate Headquarters Invensys, Foxboro, and I/A Series are trademarks of 5601 Granite Parkway Suite 1000 Invensys plc, its subsidiaries, and affiliates. Plano, TX 75024 All other brand names may be trademarks of their United States of America respective owners. www.ips.invensys.com Foxboro Global Client Support Inside U.S.: 1-866-746-6477 Outside U.S.: 1-508-549-2424 or Copyright 1999-2009 Invensys Systems, Inc. contact your local Foxboro All rights reserved representative. Facsimile: 1-508-549-4999 MB 21A Printed in U.S.A. 0209

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the P0916NG?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

ELECTRODE

product

FOXBORO 762CNA-DT MICRO CONTROLLER SINGLE STATION

product

Foxboro P0950BM-FBM43 Dual Band Intelligent Transmitter Inter

product

CONTROL PROCESSOR CP60

product

FOXBORO P0970EJ-DNBX DUAL NODEBUS INTERFACE EXTENDER MODULE