ETA USA 2210-T210-K0M1-H121.5A

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number 2210-T210-K0M1-H121.5A
Manufacturer ETA USA
Category Circuit Breakers
Price Request Quote
Lead Time Request Quote

Description

ETA-USA 2210-T210-K0M1-H121.5A Circuit Breaker. Therm/Mag | 1A | 250V AC/65V DC

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Industrial Trading is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 2210-T210-K0M1-H121.5A? We can help you find it at a competitive price!

Datasheet

Download "ETA-2210 Series-Circuit Breakers-datasheet1-950863153.pdf" (123 KiB)

Extracted Text

Thermal-Magnetic Circuit Breaker 2210-T2.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Featuring a combi-foot design for both symmetric and asymmetric rail mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status signalling. Two and three pole models are internally linked to ensure that both/all poles trip in the event of an overload on one pole, even if the actuator is held in the ON position. This CBE can be supplied in current ratings up to 32 A with a choice of characteristic curves. All screw terminals are recessed for safety. Approved to CBE standard EN 60934 (IEC 60934). Typical applications 2210-T2.. Process control equipment, robotics, machine tool control, 1-pole 3-pole 2 communications systems, instrumentation. Ordering information Technical data Type No. For further details please see chapter: Technical Information 2210 single and multipole thermal-magnetic circuit breaker Voltage rating AC 250 V; 3 AC 433 V (50/60 Hz); DC 65 V Mounting (UL: AC 277/480 V; DC 65 V) T rail mounting Current rating range 0.1...32 A for curves M1, T1, T2 Actuator design 0.1...16 A for curves F1, F2, M3 2 toggle Number of poles Auxiliary circuit 1 A, AC 240 V / DC 65 V 1 single pole protected Typical life 2 2-pole protected 3 AC 433 V; AC 250 V: 0.1...25 A 3 3-pole protected 10,000 operations at 1 x I , inductive N 5 2-pole, protected on one pole only DC 65 V: 0.1...32 A Accessories 10,000 operations at 1 x I , inductive N 0 without accessories 3 AC 433 V; AC 250 V: 32 A Terminal design (main contacts) 10,000 operations at 1 x I , resistive N K0 screw terminals Ambient temperature -30...+60 °C (-22...+140 °F) T 60 Characteristic curve F1 fast acting: therm.1.01-1.4xI ; magn.2-4xI DC (DC only) Insulation co-ordination rated impulse pollution N N F2 fast acting: therm.1.01-1.4xI ; (IEC 60664 and 60664 A) withstand voltage degree N magn.3,5-6,5xI AC/4,5-8,5xI DC 2.5 kV 2 N N M1 standard delay: therm. 1.01-1.4xI ; reinforced insulation in operating area N magn. 6-12xI AC, 7.8-15.6xI DC N N Dielectric strength T1 delayed: therm. 1.01-1.4 I ; magn. 10-20xI AC N N (IEC 60664 and 60664A) test voltage T2 thermal only, 1.01-1.4xI operating area AC 3,000 V N M3 standard delay, low resistance: therm. 1.4-1.8xI ; main/aux. circuit AC 3,000 V N magn. 6-12xI AC, 7.8-15.6xI DC pole/pole AC 1,500 V N N Auxiliary contact design Insulation resistance > 100 MΩ (DC 500 V) H without intermediate position Interrupting capacity I 0.1...5 A 400 A; 6...32 A 800 A; cn Auxiliary contacts curve T2 : 0.1...32 A 15 x I N 0 without auxiliary contacts curve M3: 0.1...2 A AC 200A /DC 400A 1 with auxiliary contacts Interrupting capacity 2 auxiliary contacts on pole 1 only (UL 1077) I 0.1...16 A 20...32 A (multipole devices) N 1- + 2-pole AC 277 V /5,000 A AC 277 V /2,000 A 3 auxiliary contacts on pole 1 and 3 3-pole 3 AC 480 V /5,000 A 3 AC 480 V /2,000 A (3-pole devices) 1- + 2-pole DC 65 V /2,000 A DC 65 V / 2,000 A Auxiliary contact function (see diagrams) 2 1 N/O contact Degree of protection operating area IP30 3 1 N/C contact (IEC 60529/DIN 40050) terminal area IP20 Auxiliary contact - terminal design Vibration curve F1: 1 screw terminals 3 g (57-500 Hz), ±0.23 mm (10-57 Hz) Current ratings curves M1, M3, T1, T2: 0.1...32 A 5 g (57-500 Hz), ±0.38 mm (10-57 Hz) to IEC 60068-2-6, test Fc 2210 - T 2 1 0 - K0 M1- H 1 2 1 - 10 A ordering example 10 frequency cycles/axis Shock curve F1: 25 g (11 ms), directions 1, 2, 3, 4, 5 10 g (11 ms), direction 6 curves M1, M3, T1, T2: 25 g (11 ms), directions 1, 2, 3, 4, 5 20 g (11 ms), direction 6 Approvals to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist Authority Voltage ratings Current ratings to IEC 60068-2-11, test Ka VDE (EN 60934) 3 AC 433 V; AC 250 V; DC 65 V 0.1...32 A Humidity 240 hours at 95 % RH UL, CSA 3 AC 480 V; AC 277 V; to IEC 60068-2-3, test Ca AC 277/480 V; DC 65 V 0.1...32 A Mass approx. 60 g per pole 06/07(070706) www.e-t-a.com 2 - 23 12A 12A 12A M1 M1 M1 Thermal-Magnetic Circuit Breaker 2210-T2.. Standard current ratings and typical internal resistance values Dimensions Current Internal resistance (Ω) 37.5 rating F1 F2 M1 T1 M3 T2 1.48 (A) fast acting fast acting standard delayed standard delay thermal 30.5 delay low resistance 1.20 for DC only for AC + DC for AC + DC nur für AC for AC + DC for AC + DC slot fitting labels from 45 25 toggles linked Phoenix 0.1 162 162 92 81 42 77 1.77 .984 for multipole Weidmüller 0.2 39.3 39.3 26.1 24.2 11.7 23 20 18 devices Wieland .787 .709 0.3 17.5 17.5 11.6 10.4 5.6 10.2 OFF ON 0.4 9.2 9.2 6,6 6.0 2.9 5.7 0.5 6.8 6.8 4,1 3.9 1.75 3,7 0.6 4.2 4.2 3 2.7 1.42 2.6 11.5 0.8 2.8 2.8 1.65 1.53 0.75 1.39 .453 9-12 .354-.472 1 1.6 1.6 1,10 0.98 0.5 0.9 1.5 0.78 0.78 0.47 0.42 0.22 0.36 2 2 0.42 0.42 0.28 0.24 0.136 0.19 Si Si 12-14 1 2 2.5 0.26 0,26 0.183 0.17 0.083 0.141 .472-.551 3 0.18 0.18 0.124 0.12 0.057 0.091 4 0.12 0.12 0.077 0.073 0.041 0.051 5 0.092 0.092 0.063 0.055 0.032 0.040 12.5 12.5 6 0.054 0.054 0.045 0.039 0.021 0.027 .492 .492 43.5 40 8 0.025 0.025 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 1.71 1.57 10 0.022 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 12 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 G-profile symmetric rail main contact terminal 16 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 ≤ 0.02 2 EN 50035-G32 EN 50022-35x7.5 max. 6 mm (AWG 10) EN 50022-35x15/1.5 (rigid conductor) 20 - - ≤ 0.02 ≤ 0.02 - ≤ 0.02 tightening torque 0.5 Nm 25 - - ≤ 0.02 ≤ 0.02 - ≤ 0.02 Si-terminal M3 32 - - ≤ 0.02 ≤ 0.02 - ≤ 0.02 2 max. 1.5 mm (AWG 16) (rigid conductor) tightening torque 0.5 Nm Internal connection diagrams unit III unit II ...-H131-... unit I OFF position ON position line (Si) N/C contact line (Si) 0I 1 11 0I 1 11 Installation drawing 12 12 (Si) (Si) > I > I operating area (reinforced insulation) 2 2 ...-H121-... line (Si) N/O contact line (Si) 0I 1 13 0I 1 13 14 14 (Si) (Si) > > I I Si Si 2 2 1 2 Shock directions mounting area 56 1 2 3 4 mm This is a metric design and millimeter dimensions take precedence ( ) inch 2 - 24 www.e-t-a.com 06/07(070706) 12 .472 5.5 11.5 .217 .453 5.5 7.5 44 .217 .295 1.73 78.5 12.5 15 3.09 .492 .591 88.5 3.48 Thermal-Magnetic Circuit Breaker 2210-T2.. Accessories Typical time/current characteristics Connector bus links -K10 -F1 -F1 0.1 … 16 A 0.1 … 16 A DC only 2 X210 589 01/2.5 mm , (AWG 14) (black) up to 20 A max. load 10000 2 X210 589 02/1.5 mm , (AWG 16) (brown) up to 13 A max. load ø2.5 1000 50 pin lugs to .099 DIN 46230 tinned copper 100 10 1 Bus bar for 1-pole units (17-way), up to 70 A max. load 0.1 2 X221 498 01 16 x 12.5 = 200 0.01 16 x .492 = 7.87 12.5 .492 2.5 1.3 0.001 12 46810 20 40 6080100 .098 .051 … times rated current 1) -F2 0.1 … 7.5 A AC/ DC IEC 664 500 V/70 A (40 °C) CE 10000 ® E-T-A GERMANY 207 3.5 1000 8.15 .138 100 Bus bar for 2-pole units (2 x 10-way), up to 120 A max. load X221 497 01 10 9 x 25 = 225 9 x .984 = 7.87 25 1 .984 12.5 12.5 2.5 1.3 .492 .492 .098 .051 0.1 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 L1 L2 ® IEC 664 500 V/70 A (40°C) CE E-T-A GERMANY 0.01 250 6.5 9.84 .138 0.001 40 6080100 12 46810 20 … times rated current Bus bar for 2-pole units (2 x 4-way), up to 120 A max. load X222 002 01 1) -F2 8 …16 A AC/ DC 3 x 25 = 75 10000 3 x .984 = 2.95 25 .984 1000 2.5 1.3 12.5 .492 .098 .051 100 L1 L2 L1 L2 L1 L2 L1 L2 IEC 664 500 V/120 A (40°C) CE 10 ® E-T-A GERMANY 104 7 1 4.09 .276 Supply terminal for bus bar (up to 70 A max. load) 0.1 X221 496 01 0.01 0.001 12 46810 20 40 6080100 … times rated current +60 °C +23 °C -30 °C 4.6 +140 °F +73.4 °F -22 °F M5 .181 1) Magnetic tripping currents are increased by 30% on DC supplies. 2 conductor size max. 10 mm (AWG 8) single or stranded conductor 13 14.5 .512 .571 17 .669 mm This is a metric design and millimeter dimensions take precedence ( ) inch 06/07(070706) www.e-t-a.com 2 - 25 22 .866 9.7 11.3 .382 .445 ~70 ~2.76 2.5 1.3 .098 .051 14 .551 14 5.2 14 .551 .205 .551 29 1.14 29 29 1.14 1.14 Trip time in seconds Trip time in seconds Trip time in seconds Thermal-Magnetic Circuit Breaker 2210-T2.. Typical time/current characteristics The time/current characteristic curve depends on the ambient temperature Multi pole devices: all poles symmetrically loaded. With single pole prevailing. In order to eliminate nuisance tripping, please multiply the circuit overload, thermal tripping will be at max. 1.7 x I with curves F1, F2, M1 N breaker current ratings by the derating factor shown below. See also section 9 and T2, and at max. 2.2 x I with curve M3. N – Technical information. 1) Magnetic tripping currents are increased by 30% on DC supplies. Ambient temperature °F -22 -4 +14 +32 +73.4 +86 +104 +122 +140 °C -30 -20 -10 0 +23 +30 +40 +50 +60 Derating factor 0.76 0.79 0.83 0.88 1 1.04 1.11 1.19 1.29 1) 1) -M1 0.1 6 A AC/DC -M1 8 32 A AC/DC -T1 0.1 6 A AC only 10000 10000 10000 1000 1000 1000 100 100 100 2 10 10 10 1 1 1 0.1 0.1 0.1 0.01 0.01 0.01 0.001 0.001 0.001 12 46810 20 406080100 12 46810 20 406080100 12 46810 20 406080100 times rated current times rated current times rated current 1) 1) -T1 8 32 A AC only -M3 0.1 5 A AC/DC -M3 6 16 A AC/DC 10000 10000 10000 1000 1000 1000 100 100 100 10 10 10 1 1 1 0.1 0.1 0.1 0.01 0.01 0.01 0.001 0.001 0.001 12 46810 20 406080100 12 46810 20 406080100 12 46810 20 406080100 times rated current times rated current times rated current -T2 0.1 6 A AC/DC -T2 8 32 A AC/DC 10000 10000 1000 1000 100 100 10 10 1 1 0.1 0.1 0.01 0.01 0.001 0.001 12 46810 20 406080100 12 46810 20 406080100 times rated current times rated current +60 ¡C +23 ¡C -30 ¡C +140 ¡F +73.4 ¡F -22 ¡F All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 2 - 26 www.e-t-a.com 06/07(070706) Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds

Related Products

None available

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Industrial Trading are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Industrial Trading is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.031 seconds.