EMERSON NETWORK POWER 142-0701-335

Description
CONN JACK ECEPT RA MOISTURE SEAL
Part Number
142-0701-335
Price
Request Quote
Manufacturer
EMERSON NETWORK POWER
Lead Time
Request Quote
Category
None
Datasheet
Extracted Text
SMA 50 Ohm INCHES (MILLIMETERS) Right Angle PC Mount CUSTOMER DRAWINGS AVAILABLE UPON REQUEST Jack Receptacle - Moisture Seal* VSWR & NICKEL BODY, GOLD INTERFACE FREQ. RANGE IR COMPATIBLE* VSWR: N/A 142-0701-335* 0-18 GHz * Tin/Lead solder dipped legs and Moisture Sealed for IR Reflow Compatibility. Mounting Hole Layout TM Johnson Components ¥ P.O. Box 1732 ¥ Waseca, MN 56093-0832 ¥ 1-800-247-8256 ¥ Fax: 507-833-6287 ¥ www.johnsoncomponents.com SMA - 50 Ohm Connectors INCHES (MILLIMETERS) Specifications CUSTOMER DRAWINGS AVAILABLE UPON REQUEST ELECTRICAL RATINGS Impedance: 50 ohms Insertion Loss: (dB maximum) Frequency Range: Straight flexible cable connectors Dummy loads .......................................................................... 0-2 GHz and adapters ...................... 0.06 f (GHz), tested at 6 GHz Flexible cable connectors ................................................... 0-12.4 GHz Right angle flexible cable Uncabled receptacles, RA semi-rigid and adapters ........... 0-18.0 GHz connectors ......................... 0.15 f (GHz), tested at 6 GHz Straight semi-rigid cable connectors and Straight semi-rigid cable field replaceable connectors ............................................... 0-26.5 GHz connectors with contact ..... 0.03 f (GHz), tested at 10 GHz VSWR: (f = GHz) Straight Right Angle Right angle semi-rigid cable Cabled Connectors Cabled Connectors connectors ......................... 0.05 f (GHz), tested at 10 GHz RG-178 cable .............................. 1.20 + .025f 1.20 + .03f Straight semi-rigid cable RG-316, LMR-100 cable .............. 1.15 + .02f 1.15 + .03f connectors w/o contact ...... 0.03 f (GHz), tested at 16 GHz RG-58, LMR-195 cable ................ 1.15 + .01f 1.15 + .02f Straight low loss flexible RG-142 cable ............................... 1.15 + .01f 1.15 + .02f cable connectors ................ 0.06 f (GHz), tested at 1 GHz LMR-200, LMR-240 cable ............ 1.10 + .03f 1.10 + .06f Right Angle low loss flexible .086 semi-rigid ............................ 1.07 + .008f 1.18 + .015f cable connectors ................ 0.15 f (GHz), tested at 1 GHz .141 semi-rigid (w/contact) .......... 1.05 + .008f 1.15 + .015f Uncabled receptacles, field replaceable, dummy loads .....................N/A .141 semi-rigid (w/o contact) ...... 1.035 + .005f Insulation Resistance: 5000 megohms minimum Jack-bulkhead jack adapter and plug-plug adapter ................. 1.05 + .01f Contact Resistance: (milliohms maximum) Initial After Environmental Jack-jack adapter and plug-jack adapter ............................... 1.05 + .005f Center contact (straight cabled connectors Uncabled receptacles, dummy loads .................................................. N/A and uncabled receptacles) ........................... 3.0* 4.0* Field replaceable (see page 59) ......................................................... N/A Center contact (right angle cabled = Working Voltage: (Vrms maximum) connectors and adapters) ..............................4.0 6.0 Connectors for Cable Type Sea Level 70K Feet Field replaceable connectors ........................6.0 8.0 RG-178 ...................................................................... 170 45 Outer contact (all connectors) ........................... 2.0 N/A RG-316; LMR-100, 195, 200 ..................................... 250 65 Braid to body (gold plated connectors) .............0.5 N/A RG-58, RG-142, LMR-240, .086 semi-rigid, Braid to body (nickel plated connectors) ...........5.0 N/A uncabled receptacles, .141 semi-rigid w/o contact ... 335 85 *N/A where the cable center conductor is used as a contact .141 semi-rigid with contact and adapters ................. 500 125 RF Leakage: (dB minimum, tested at 2.5 GHz) Dummy loads ................................................................................. N/A Flexible cable connectors, adapters and .141 semi-rigid = Dielectric Withstanding Voltage: (VRMS minimum at sea level) connectors w/o contact ............................................................. -60 dB Connectors for RG-178 ................................................................... 500 Field replaceable w/o EMI gasket .............................................. -70 dB Connectors for RG-316; LMR-100, 195, 200 .................................. 750 .086 semi-rigid connectors and .141 semi-rigid connectors Connectors for RG-58, RG-142, LMR-240, .086 semi-rigid, with contact, and field replaceable with EMI Gasket ................ -90 dB field replaceable, uncabled receptacles ...................................... 1000 Two-way adapters ...................................................................... -90 dB Connectors for .141 semi-rigid with contact and adapters ............ 1500 Uncabled receptacles, dummy loads .............................................. N/A Connectors for .141 semi-rigid w/o contact, dummy loads .............. N/A RF High Potential Withstanding Voltage: (Vrms minimum, tested at 4 == Corona Level: (Volts minimum at 70,000 feet) and 7 MHz) Connectors for RG-178 ................................................................... 125 Connectors for RG-178 ................................................................... 335 Connectors for RG-316; LMR-100, 195, 200 .................................. 190 Connectors for RG-316; LMR-100, 195, 200 .................................. 500 Connectors for RG-58, RG-142, LMR-240, 086 semi-rigid, Connectors for RG-58, RG-142, LMR-240, .086 semi-rigid, uncabled receptacles, .141 semi-rigid w/o contact .......................... 250 .141 semi-rigid cable w/o contact, uncabled receptacles .............. 670 Connectors for .141 semi-rigid with contact and adapters .............. 375 Connectors for .141 semi-rigid with contact and adapters ............ 1000 Dummy loads ...................................................................................... N/A Power Rating (Dummy Load): 0.5 watt @ + 25°C, derated to 0.25 watt @ +125°C MECHANICAL RATINGS Engagement Design: MIL-C-39012, Series SMA Cable Retention: Axial Force*(lbs) Torque (in-oz) Engagement/Disengagement Force: 2 inch-pounds maximum Connectors for RG-178 ............................ 10 N/A Connectors for RG-316, LMR-100 ........... 20 N/A Mating Torque: 7 to 10 inch-pounds Bulkhead Mounting Nut Torque: 15 inch-pounds Connectors for LMR-195, 200 .................. 30 N/A Coupling Proof Torque: 15 inch-pounds minimum Connectors for RG-58, LMR-240 ............. 40 N/A Connectors for RG-142 ............................ 45 N/A Coupling Nut Retention: 60 pounds minimum Contact Retention: Connectors for .086 semi-rigid ................. 30 16 6 lbs. minimum axial force (captivated contacts) Connectors for .141 semi-rigid ................. 60 55 *Or cable breaking strength whichever is less. 4 inch-ounce minimum torque (uncabled receptacles) Durability: 500 cycles minimum 100 cycles minimum for .141 semi-rigid connectors w/o contact ENVIRONMENTAL RATINGS (Meets or exceed the applicable paragraph of MIL-C-39012) Temperature Range: - 65°C to + 165°C Shock: MIL-STD-202, Method 213, Condition I Thermal Shock: MIL-STD-202, Method 107, Condition B Vibration: MIL-STD-202, Method 204, Condition D Corrosion: MIL-STD-202, Method 101, Condition B Moisture Resistance: MIL-STD-202, Method 106 †Avoid user injury due to misapplication. See safety advisory definitions inside front cover. TM Johnson Components ¥ P.O. Box 1732 ¥ Waseca, MN 56093-0832 ¥ 1-800-247-8256 ¥ Fax: 507-833-6287 ¥ www.johnsoncomponents.com SMA - 50 Ohm Connectors INCHES (MILLIMETERS) Specifications CUSTOMER DRAWINGS AVAILABLE UPON REQUEST MATERIAL SPECIFICATIONS Bodies: Brass per QQ-B-626, gold plated* per MIL-G-45204 .00001" min. or nickel plated per QQ-N-290 Contacts: Male - brass per QQ-B-626, gold plated per MIL-G-45204 .00003" min. Female - beryllium copper per QQ-C-530, gold plated per MIL-G-45204 .00003" min. Nut Retention Spring: Beryllium copper per QQ-C-533. Unplated Insulators: PTFE fluorocarbon per ASTM D 1710 and ASTM D 1457 or Tefzel per ASTM D 3159 or PFA 340 per ASTM Expansion Caps: Brass per QQ-B-613, gold plated per MIL-G-45204 .00001" min. or nickel plated per QQ-N-290 Crimp Sleeves: Copper per WW-T-799 or brass per QQ-B-613, gold plated per MIL-G-45204 .00001" min. or nickel plated per QQ-N-290 Mounting Hardware: Brass per QQ-B-626 or QQ-B-613, gold plated per MIL-G-45204 .00001" min. or nickel plated per QQ-N-290 Seal Rings: Silicone rubber per ZZ-R-765 EMI Gaskets: Conductive silicone rubber per MIL-G-83528, Type M * All gold plated parts include a .00005" min. nickel underplate barrier layer. Mating Engagement for SMA Series per MIL-C-39012 JACK PLUG PLUG JACK NOTES 1. ID OF CONTACT TO MEET VSWR, CONTACT RESISTANCE AND INSERTION WITHDRAWAL FORCES WHEN MATED WITH DIA .0355-.0370 MALE PIN. TM Johnson Components ¥ P.O. Box 1732 ¥ Waseca, MN 56093-0832 ¥ 1-800-247-8256 ¥ Fax: 507-833-6287 ¥ www.johnsoncomponents.com
Frequently asked questions
How does Industrial Trading differ from its competitors?

Is there a warranty for the 142-0701-335?

Which carrier will Industrial Trading use to ship my parts?

Can I buy parts from Industrial Trading if I am outside the USA?

Which payment methods does Industrial Trading accept?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods