Cutler Hammer XTOB057DC1 Overload Relay - 40-57A, D Frame, Thermal Overload, Class 10

Part Number

XTOB057DC1

Price

Request Quote

Manufacturer

CUTLER-HAMMER

Lead Time

Request Quote

Category

Relays

Specifications

Ambient Temp. Range

-13 to 131 Degrees F

Amp Setting Range

40 to 57 Amps

Approvals

UL, CSA, CE, ATEX

Comments

Direct Mounting to XT Series D Frame Contactor

Connection Type

Wire

H x W x D (in.)

4.02 x 2.36 x 3.12

Item Category

Overload Relays

Item Number

XTOB057DC1

Manufacturer

Eaton Cutler Hammer

Output Contacts

1NO/1NC

Poles

3

Reset Type

Manual/Automatic

RoHS

Yes

Series

XTOB

Subcategory

Thermal Overload Relays

Trip Class

10

Type

Bimetallic

Datasheet

pdf file

CutlerHammer-XTOB057DC1 -ds1-860270158.PDF

5037 KiB

Extracted Text

IEC Contactors & Starters 34-1 March 2009 Contents Description Page XT IEC Power Control Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-2 Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-15 Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-30 34 Overload Relays — XTOB, XTOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-104 Overload Relays — C396 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-113 Manual Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-121 Combination Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-157 Contactors and Starters — Enclosed Control . . . . . . . . . . . . . . . . . . . . . . 34-174 Combination Motor Controllers — Enclosed Control . . . . . . . . . . . . . . . 34-202 Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-210 IT. Electro-Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-228 Contactors — Full Voltage, Non-reversing and Reversing . . . . . . . . . . . . 34-230 Starters — Full Voltage, Non-reversing and Reversing. . . . . . . . . . . . . . . 34-233 For Replacement Only Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-256 Contactors — Non-reversing and Reversing . . . . . . . . . . . . . . . . . . . . . . . 34-258 Freedom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-261 Contactors — Non-reversing and Reversing . . . . . . . . . . . . . . . . . . . . . . . 34-262 Starters — Fixed Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-266 Relays — Fixed Heater Overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-269 Starters — Interchangeable Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-270 Relays — Interchangeable Heater Overload . . . . . . . . . . . . . . . . . . . . . . . 34-273 MMPs & Manual and Combination Motor Controllers . . . . . . . . . . . . . . . . . 34-290 Type A302 Manual Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-290 Types A307, A308, A309 Manual Motor Protectors . . . . . . . . . . . . . . . . . 34-294 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-300 IEC Contactors and Starters CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters IEC Contactors & Starters 34-2 XT IEC Power Control March 2009 Relays and Timers Contents Product Description Standards and Certifications Description Page Eaton’s new line of XT Relays and ■ IEC EN 60947 Timers includes mini and standard ■ CE Approved Catalog Number frame control relays and auxiliary Selection . . . . . . . . . . . . . . . 34-3 ■ UL contacts, mini electronic on-delay and Product Selection . . . . . . . . . 34-4 ■ CSA multi-function timers and an electronic ■ CCC Accessories . . . . . . . . . . . . . . 34-5 star-delta (wye-delta) timer for use in 34 star-delta (wye-delta) combinations. ■ ATEX Technical Data and Because XT meets UL, CSA, CCC and Specifications . . . . . . . . . . . 34-10 CE standards, it is the perfect product Dimensions . . . . . . . . . . . . . . 34-13 solution for IEC applications all over Reference Data . . . . . . . . . . . . 34-210 the world. The compact, space saving, and easy to install XT line of IEC Instructional Leaflets contactors and starters is the efficient and effective solution for customer Pub51219 Inside of Packaging applications. XTRM Mini Control Relays Features Pub51210 Inside of Packaging 7-15A XTCE Contactors ■ For use with Mini and Standard and XTRE Control frame size contactors and starters Relays ■ Control Relays Pub51244 XTTR Electronic ❑ AC Control from 12V to 550V 50 Star-Delta (Wye-Delta) Hz, 600V 60 Hz Timer ❑ DC Control from 12V to 220V Pub51245 XTMT Mini Electronic ■ On-Delay and Multi-Function Timers On-Delay and ❑ 24 – 240V AC/DC Control Multi-Function Timers ■ Available with screw or spring cage terminals ■ 4-Pole Configurations ■ IP20 finger and back-of-hand proof ■ Large ambient temperature range: -25° to 50°C [-13° to 122°F] ■ The XTRE Control Relays have posi- tively driven contacts between the relay and the auxiliary contact mod- ules as well as within the auxiliary contact modules For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-3 XT IEC Power Control March 2009 Relays and Timers Catalog Number Selection Table 34-1. XT — Relay Catalog Numbering System X T R E C 1 0 B 2 2 A D Product Line Prefix Coil Code 34 XT = XT IEC Power Control See Table 34-5 on Page 34-4. Contact Product Family Code Configuration RM = Mini IEC Control Relay 40 = 4NO RE = IEC Control Relay 31 = 3NO-1NC 22 = 2NO-2NC Terminations Blank = Screw Terminals Frame C = Spring Cage Terminals For XTRM A = 45 mm — Mini Conventional For XTRE Thermal Current Rating B = 45 mm — Standard 10 = 10A Table 34-2. XT — Timers Catalog Numbering System X T M T 6 B 3 0 S 1 1 B Product Line Prefix Coil Code XT = XT IEC Power Control B = 24 – 240V AC/DC Product Family Code Function MT = Mini IEC Timing Relay For XTMT Time Range Max. TR = Electronic Timing Relay 11 = On-Delay Star-Delta (Wye-Delta) For XTMT 70 = Adjustable 30S = 1.5 – 30 s For XTTR Conventional 60H = 0.05 – 1 s 51 = Star-Delta Thermal Current 0.15 – 3 s Rating 0.5 – 10 s 3 – 60 s 6 = 6A 0.15 – 3 min 0.5 – 3 min 3 – 60 min Frame 0.15 – 3 h A = 45 mm 0.5 – 3 h 3 – 60 h For XTTR 60S = 3 – 60 s CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-4 XT IEC Power Control March 2009 Relays and Timers Product Selection Mini Control Relays 34 Table 34-3. Mini Control Relays Conventional Contact Rated Operational Current Circuit Screw Spring Cage Price (A) Thermal Configuration AC-15 I Symbol Terminals Terminals U.S. $ e Current 220 – 240V 380 – 415V 500V Catalog Catalog AC DC I (A) � � th Number Number Coil Coil 10 4NO 6 3 1.5 XTRM10A40_ XTRMC10A40_ A1 13 23 33 43 A2 14 24 34 44 10 3NO-1NC 6 3 1.5 XTRM10A31_ XTRMC10A31_ A113 21 33 43 A2 14 22 34 44 10 2NO-2NC 6 3 1.5 XTRM10A22_ XTRMC10A22_ A1 13 21 31 43 A2 14 22 32 44 � Underscore (_) indicates magnet coil suffix required. See Table 34-5. Control Relays Table 34-4. Control Relays Conventional Contact Rated Operational Current Circuit Screw Terminals Spring Cage Price (A) Thermal Configuration AC-15 I Symbol Terminals U.S. $ e Current Open 220 – 240V 380 – 415V 500V Catalog Catalog AC DC at 60°C I (A) � � th Number Number Coil Coil 16 4NO 6 4 1.5 XTRE10B40_ XTREC10B40_ A1 13 23 33 43 A2 14 24 34 44 16 3NO-1NC 6 4 1.5 XTRE10B31_ XTREC10B31_ A113 21 33 43 A2 14 22 34 44 � � XTREC10B22_ 16 2NO-2NC 6 4 1.5 XTRE10B22_ 13 A1 21 31 43 A2 14 22 32 44 � Underscore (_) indicates magnet coil suffix required. See Table 34-5. � DC operated control relays XTRE(C)10B22_ can only be combined with 2-pole auxiliary contacts. Table 34-5. Coil Voltage Suffix Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code 110V 50 Hz, 120V 60 Hz A 208V 60 Hz E 24V 50 Hz U 220V 50 Hz, 240V 60 Hz B 190V 50 Hz, 220V 60 Hz G 42V 50 Hz, 48V 60 Hz W 230V 50 Hz F 240V 50 Hz, 277V 60 Hz H 48V 50 Hz Y 24V 50/60 Hz T 380V 50 Hz, 440V 60 Hz L 120V DC AD 24V DC TD 400V 50 Hz N 220V DC BD 415V 50 Hz, 480V 60 Hz C 380V 60 Hz P 12V DC RD 550V 50 Hz, 600V 60 Hz D 12V 50/60 Hz R 48V DC WD Notes: ■ Orders must be placed in multiples of the package quantity listed. ■ DC operated control relays have a built-in suppressor circuit. Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-5 ■ Contact terminal numbers to EN50011. Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-13 ■ Coil terminal numbers to EN50005. Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-5 XT IEC Power Control March 2009 Relays and Timers Accessories Auxiliary Contacts 34 Table 34-6. Front Mount Auxiliary Contacts for Use with XTRM Mini Control Relays Conventional Rated Operational Contact Contact Package Screw Spring Cage Price � thermal current, Current AC-15 I (A) Configuration Sequence Qty. Terminals Terminals U.S. $ e I Open (A) th 220V 380V 500V Catalog Catalog 230V 400V Number Number 240V 415V 10 4 2 1.5 2NC 5 XTMCXFA02 — 51 61 52 62 10 4 2 1.5 1NO-1NC 5 XTMCXFA11 XTMCXFAC11 61 53 54 62 10 4 2 1.5 2NO 5 XTMCXFA20 — 53 63 54 64 � 10 4 2 1.5 1NO -1NC 5 XTMCXFAL11 — E L 57 65 58 66 10 4 2 1.5 4NC 5 XTMCXFA04 XTMCXFAC04 51 61 71 81 52 62 72 82 10 4 2 1.5 1NO-3NC 5 XTMCXFA13 XTMCXFAC13 61 53 71 81 54 62 72 82 10 4 2 1.5 2NO-2NC 5 XTMCXFA22 XTMCXFAC22 53 61 71 83 54 62 72 84 10 4 2 1.5 3NO-1NC 5 XTMCXFA31 XTMCXFAC31 53 61 73 83 54 62 74 84 10 4 2 1.5 4NO 5 XTMCXFA40 XTMCXFAC40 53 63 73 83 54 64 74 84 � � 10 4 2 1.5 1NO-1NC 5 XTMCXFAL22 XTMCXFCLC22 57 65 71 83 1NO -1NC E L 58 66 72 84 � Orders must be placed in multiples of package quantity listed. � 1 early-make contact (NO ), 1 late-break contact (NC ). E L Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-6 XT IEC Power Control March 2009 Relays and Timers � Table 34-7. Front Mount Auxiliary Contacts for Use with XTRE Control Relays Conventional Poles Rated Operational Contact Circuit Symbol Pkg. Screw Terminals Spring Cage Price � Thermal Current, Current AC-15 I (A) Configuration Qty. Terminals U.S. $ e I (A), Open at 60°C th 220V 380V 500V Catalog Catalog 230V 400V Number Number 240V 415V 6 3 1.5 5 16 2 2NO XTCEXFAC20 XTCEXFACC20 5363 34 5464 5 16 2 6 3 1.5 1NO-1NC XTCEXFAC11 XTCEXFACC11 53 61 54 62 5 16 2 6 3 1.5 2NC XTCEXFAC02 XTCEXFACC02 51 61 52 62 � � 6 3 1.5 5 16 2 1NO -1NC XTCEXFALC11 XTCEXFALCC11 E L 57 65 58 66 16 4 6 3 1.5 4NO 5 XTCEXFAC40 XTCEXFACC40 536373 83 5464 7484 6 3 1.5 5 16 4 3NO-1NC XTCEXFAC31 XTCEXFACC31 53 61 73 83 54 62 74 84 6 3 1.5 5 16 4 2NO-2NC XTCEXFAC22 XTCEXFACC22 53 61 71 83 5462 72 84 16 4 6 3 1.5 1NO-3NC 5 XTCEXFAC13 XTCEXFACC13 536171 81 546272 82 6 3 1.5 5 16 4 4NC XTCEXFAC04 XTCEXFACC04 5161 71 81 526272 82 � � 16 4 6 3 1.5 1NO-1NC 5 XTCEXFCLC22 XTCEXFCLCC22 5765 71 83 1NO -1NC E L 5866 72 84 � Orders must be placed in multiples of package quantity listed. � 1 early-make contact (NO ), 1 late-break contact (NC ). E L � Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules (not NO and NC contacts) and E L between the auxiliary contacts and built-in contacts of the XTRE control relays. Suppressors For AC operated contactors 50 – 60 Hz. On DC operated con- tactor relays and on XTRE10B the suppressor circuit is built- in. Note drop-out relay. �� Varistor Suppressor � Table 34-9. Varistor Suppressor for XTRM Voltage For Use Circuit Package Catalog Price � A1 with… Symbol Qty. Number U.S. $ Contact Sequence 24 – 48 XTRM6A…, 10 XTMCXVSW A1 XTRM9A… A2 48 – 130 XTRM6A…, 10 XTMCXVSA XTRM9A… A2 110 – 250 XTRM6A…, 10 XTMCXVSB Table 34-8. Varistor Suppressor for XTRE XTRM9A… Voltage For Use Pkg. Catalog Price 380 – 415 XTRM6A…, 10 XTMCXVSN � XTRM9A… with… Qty. Number U.S. $ 24 – 48 XTRMC6A…, 10 XTMCXVSCW 24 – 48 XTCE007B – XTCE015B, 10 XTCEXVSBW XTRMC9A… 48 – 130 XTCF020B, XTRE(C)10B 10 XTCEXVSBA 48 – 130 XTRMC6A…, 10 XTMCXVSCA 130 – 240 10 XTCEXVSBB XTRMC9A… 240 – 500 10 XTCEXVSBC 110 – 250 XTRMC6A…, 10 XTMCXVSCB � XTRMC9A… Note drop-out delay. � � For AC operated contactors, 50/60 Hz. DC operated contactors have an For AC operated contactors, 50/60 Hz. DC operated contactors have integrated suppressor. integrated varistor suppressors. � � Orders must be placed in multiples of package quantity listed. Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-7 XT IEC Power Control March 2009 Relays and Timers �� Varistor Suppressor with Integrated LED Free-Wheel Diode Suppressor A1 A2 Contact Sequence 34 In addition to the built-in suppressor circuit for DC actuated Table 34-10. Varistor Suppressor for XTRE contactors. Prevents negative breaking voltage when con- Voltage For Use Pkg. Catalog Price tactors are used in combination with a safety PLC. � with… Qty. Number U.S. $ Table 34-13. Free-Wheel Diode Suppressor for XTRE 24 – 48 XTRE(C)10B 10 XTCEXVSLBW 130 – 240 10 XTCEXVSLBB Voltage For Use Pkg. Catalog Price � with… Qty. Number U.S. $ � Note drop-out delay. � 12 – 250 DC XTRE10B 10 XTCEXDSB For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor. � Orders must be placed in multiples of package quantity listed. � Orders must be placed in multiples of package quantity listed. Voltage Indicator �� RC Suppressor A1 A1 Contact Sequence Contact Sequence A2 A2 Table 34-14. Voltage Indicator for XTRE Table 34-11. RC Suppressor for XTRE Voltage For Use Pkg. Catalog Price � Voltage For Use Pkg. Catalog Price with… Qty. Number U.S. $ � with… Qty. Number U.S. $ 24 – 48 XTRE(C)10B 10 XTCEXVIBW 24 – 48 XTRE(C)10B 10 XTCEXRSBW 110 – 120 10 XTCEXVIBA 48 – 130 10 XTCEXRSBA 110 – 250 10 XTCEXVIBB 110 – 240 10 XTCEXRSBB � Orders must be placed in multiples of package quantity listed. 240 – 500 10 XTCEXRSBC � Note drop-out delay. � For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor. � Orders must be placed in multiples of package quantity listed. � Table 34-12. RC Suppressor for XTRM Voltage For Use Circuit Package Catalog Price with… Symbol Qty. Number U.S. � $ 24 – 48 XTRM6A…, 10 XTMCXRSW A1 XTRM9A… 48 – 130 XTRM6A…, 10 XTMCXRSA XTRM9A… A2 110 – 250 XTRM6A…, 10 XTMCXRSB XTRM9A… 24 – 48 XTRMC6A…, 10 XTMCXRSCW XTRMC9A… 48 – 130 XTRMC6A…, 10 XTMCXRSCA XTRMC9A… 110 – 250 XTRMC6A…, 10 XTMCXRSCB XTRMC9A… � For AC operated contactors, 50/60 Hz. Note drop-out delay. � Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-8 XT IEC Power Control March 2009 Relays and Timers � � Connector Mechanical Interlock Table 34-15. Connector Table 34-16. Mechanical Interlock For Use Pkg. Catalog Price For Use Pkg. Catalog Price � � with… Qty. Number U.S. $ with… Qty. Number U.S. $ XTRE(C)10B 50 XTCEXCNC XTRE10B... 5 XTCEXMLB 34 XTRM10A 50 XTMCXCN XTRM10A... 5 XTMCXML � For mechanically arranging contactors in combinations. Distance between contactors is 0 mm. � Orders must be placed in multiples of package quantity listed. � For two contactors with AC or DC operated magnet system which are horizontally or vertically mounted. For B frame, mechanical lifespan is 6 2.5 x 10 operations and the distance between contactors is 0 mm. � Orders must be placed in multiples of package quantity listed. Electronic Timer Modules Front (Top) mounted timer modules for use with XTRE10B control relays. Can not be combined with top mount auxil- iary contacts, XTCEXF_C_. Table 34-17. Electronic Timer Modules for XTRE Voltage Contact Timing Range For Use Pkg. Catalog Price Sequence with… Qty. Number U.S. $ On-Delayed 24V AC/DC 0.05 – 1 s XTRE10B_ 1 XTCEXTEEC11T A1 57 65 0.5 – 10 s 100 – 130V AC XTCEXTEEC11A 15 – 100 s 200 – 240V AC XTCEXTEEC11B A2 58 66 Off-Delayed 24V AC/DC 0.05 – 1 s XTRE10B_ 1 XTCEXTED1C11T A1 57 65 100 – 130V AC XTCEXTED1C11A 200 – 240V AC XTCEXTED1C11B 24V AC/DC 0.5 – 10 s XTRE10B_ 1 XTCEXTED10C11T A2 58 66 100 – 130V AC XTCEXTED10C11A 200 – 240V AC XTCEXTED10C11B 24V AC/DC 5 – 100 s XTRE10B_ 1 XTCEXTED100C11T 100 – 130V AC XTCEXTED100C11A 200 – 240V AC XTCEXTED100C11B Star-Delta 24V AC/DC 1 – 30 s XTRE10B_ 1 XTCEXTEYC20T A1 57 67 100 – 130V AC XTCEXTEYC20A 200 – 240V AC XTCEXTEYC20B 58 A2 68 Sealable Shroud Transparent sealable shroud used to protect elec- XTCEXTEE, 1 XTCEXTESHRD tronic timer modules from unwanted access. XTCEXTED, XTCEXTEY Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-9 XT IEC Power Control March 2009 Relays and Timers Mini Electronic Timers Table 34-18. Mini Electronic On-Delay Timers 34 Conventional Rated Operational Current Time Function Terminal Marking Catalog Price Thermal Current I AC-11 Amps Range According to Number U.S. $ e I (A) EN 50042 e 220/230/240V 380/400/440V 6 3 3 1.5 – 30 sec Fixed, XTMT6A30S11B A1 15 On-delay 6 3 6 0.05 – 1 sec Fixed, XTMT6A60H11B 0.15 – 3 sec On-delay 0.5 – 10 sec 16 18 A2 3 – 60 sec 0.15 – 3 min 0.5 – 10 min 3 – 60 min 0.15 – 3 h 0.5 – 10 h 3 – 60 h 6 3 3 0.05 – 1 sec Adjustable: XTMT6A60H70B Z1 Z2 0.15 – 3 sec On-delayed; A1 15 0.5 – 10 sec Fleeting contact on 3 – 60 sec energization; 0.15 – 3 min Flashing; Pulse 0.5 – 10 min generating; ON-OFF A2 16 18 3 – 60 min 0.15 – 3 h 0.5 – 10 h 3 – 60 h Notes — Actuating Voltage 24 – 240 50/60 Hz 24 – 240V DC Admissible Cable Length Connection to 2 Cable unscreened, with cable cross-section 0.5 – 1.5 mm Y1/Y2, Z1/Z2 Two-core cable M250 Two-core cable in the same cable duct with the main cable, 50/60 Hz M50 Electronic Star-Delta (Wye-Delta) Timers Table 34-19. Electronic Star-Delta (Wye-Delta) Timers Conventional Rated Operational Current Time Function Terminal Marking Catalog Price Thermal Current I AC-11 Amps Range According to Number U.S. $ e I (A) EN 50042 e 230V 400V 6333 – 60 sec Fixed, Star-Delta XTTR6A60S51B 17 A1 A2 18 28 Notes — Actuating Voltage 24 – 240 50/60 Hz 24 – 240V DC Admissible Cable Length Connection to 2 Cable unscreened, with cable cross-section 0.5 – 1.5 mm B1, Z1/Z2 Two-core cable M250 Two-core cable in the same cable duct with the main cable, 50/60 Hz M50 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-10 XT IEC Power Control March 2009 Relays and Timers Technical Data and Specifications Table 34-20. Relays and Timers — Technical Data and Specifications Description XTRE XTCEXFAC_ XTCEXTE_ XTRM XTMCXFA_ General Standards IEC/EN 60947, VDE 0660, UL, CSA DIN EN 61812, IEC/EN 60947, VDE 0660, UL, CSA IEC/EN 60947, VDE 060, UL, CSA 34 Lifespan, Mechanical AC Operated 20,000,000 10,000,000 3,000,000 10,000,000 10,000,000 DC Operated 20,000,000 10,000,000 3,000,000 20,000,000 20,000,000 Maximum operating frequency (ops/hr) 9000 9000 — 9000 9000 Climatic Proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 Ambient Temperature Open (°C, min/max) -25/60 -25/60 -40/80 -25/50 -25/50 Enclosed (°C, min/max) -25/40 -25/40 -25 – 60 -25/40 -25/40 Ambient Temperature for Storage (°C, min/max) -40/80 -40/80 -25 – 40 — — Mounting Position As required, As required, except vertically A1/A2 at 30° not suspended the bottom 90° 90° 90° 180° Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms Base unit with auxiliary contact module Make contact 7g 7g 6g 10g 10g Break contact 5g 5g 6g 8g 8g Degree of Protection IP20 IP20 IP20 IP20 IP20 Protection against direct contact from the front when Finger- and back-of-hand proof actuated by a perpendicular test finger (IEC 536) Weight AC operated (kg) 0.23 0.05 0.08 0.17 — DC operated (kg) 0.28 0.05 0.08 0.20 — Terminal capacity Screw terminals 2 Solid (mm ) 1 x (0.75 – 4)0. 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 1.5) 2 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 1.5) 1 x (0.75 – 1.5) 2 x (0.75 – 2.5) 2 x (0.75 – 1.5) 2 x (0.75 – 1.5) Solid or stranded (AWG) 18 – 14 18 – 14 18 – 14 Terminal screw M3.5 M3.5 M3.5 M3.5 M3.5 Pozidriv screwdriver Size 2 Size 2 Size 2 Size 2 Size 2 Standard screwdriver (mm) 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 1 x 6 1 x 6 1 x 6 Max. tightening torque (Nm) 1.2 1.2 1.2 1.2 1.2 Spring cage terminals 2 Solid (mm ) 1 x (0.75 – 2.5) — 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) — 2 x (0.75 – 2.5) 2 Flexible with or without ferrule DIN 46228 (mm ) 1 x (0.75 – 2.5) — 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) — 2 x (0.75 – 2.5) Solid or stranded (AWG) 18 – 14 — 18 – 14 Standard screwdriver (mm) 0.6 x 3.5 — 0.6 x 3.5 Contacts Interlocked opposing contacts to ZH 1/457, Yes Yes No Yes Yes including auxiliary contact module Rated impulse withstand voltage (U ) V AC 6000 6000 6000 6000 6000 imp Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3 Rated insulation voltage (U ) V AC 690 690 600 690 690 i Rated operational voltage (U ) V AC 690 500 400 600 600 e Safe isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and auxiliary contacts (V AC) 400 400 250 300 300 Between the auxiliary contacts (V AC) 400 400 250 300 300 Rated operational current AC-15 220/240V I 6 6 Please inquire 6 4 e 380/415V I 4 3 Please inquire 3 2 e 500V I 1.5 — — 1.5 1.5 e For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-11 XT IEC Power Control March 2009 Relays and Timers Table 34-20. Relays and Timers — Technical Data and Specifications (Continued) Description XTRE XTCEXFAC_ XTCEXTE_ XTRM XTMCXFA_ Contacts (Continued) � DC-13 DC13 L/R ≤ 15 mS Contacts in series: Voltage: 1 24V 10 10 — 2.5 2.5 1 60V 6 6 — — — 2 60V 10 10 — 2.5 2.5 34 1 110V 3 3 — — — 3 110V 6 6 — 1.5 1.5 1 220V 1 1 — — — 3 220V 5 5 — 0.5 0.5 DC-13 L/R ≤ 50 mS Contacts in series: Voltage: 3 24V 4 — — — — 3 60V 4 — — — — 3 110V 2 — — — — 3 220V 1 — — — — -8 -8 Control circuit reliability Failure rate = <10 , < one failure — Failure rate = <10 , < one failure (at U = 24V DC, U = 17, I = 5.4 mA) in 100 million operations in 100 million operations e min min Conventional thermal current (I) 16166 1010 th Short-circuit rating without welding Maximum overcurrent protective device 220/240V – XTPR Frame B 4 — — 4 4 380/415V – XTPR Frame B 4 — — 4 4 Short-circuit protection, max. fuse 500V (A gG/gL) 10 10 6 6 6 500V (A fast) — — — 10 10 Current heat losses at load of I th AC operated (W) 0.3 0.3 — 0.2 0.2 DC operated (W) 0.3 0.3 — 0.3 0.3 Magnet Systems Pick-up and drop-out values AC operated Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz (Pick-up x U ) 0.8 – 1.1 — 0.85 – 11 0.8 – 1.1 — c Dual-frequency coil 50/60 Hz (Pick-up x U ) 0.8 – 1.1 — — 0.85 – 1.1 — c � DC operated Pick -up voltage (Pick-up x U ) 0.8 – 1.1 — 0.7 – 1.2 0.85 – 1.3 — c At 24V: without auxiliary contact module (40°C) (Pick-up x U ) 0.7 – 1.3 — — 0.7 – 1.3 — c Power consumption Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Pick-up VA 24 — — 25 — Pick-up W 19 — — 22 — Sealing VA 3.4 — 2 4.6 — Sealing W 1.2 — 1.8 1.3 — Dual-frequency coil 50/60 Hz at 50 Hz Pick-up VA 27 — — 30 — Pick-up W 22 — — 26 — Sealing VA 4.2 — — 5.4 — Sealing W 1.4 — — 1.6 — Dual-frequency coil 50/60 Hz at 60 Hz Pick-up VA 25 — — 29 — Pick-up W 21 — — 24 — Sealing VA 3.3 — — 3.9 — Sealing W 1.2 — — 1.2 — DC operated Pull-in = sealing (W) 3 — — 2.6 — Duty factor (% DF) 100 — 100 100 — Switching times at 100% U (approximate values) c AC operated closing delay (mS) ≤21 — — 14 – 21 — AC operated NO contact opening delay (mS) ≤18 — — 8 – 18 — AC operated with auxiliary contact module, max. closing delay (mS) — — — 45 45 DC operated closing delay (mS) ≤31 — — 26 – 35 — DC operated NO contact opening delay (mS) ≤12 — — 15 – 25 — DC operated with auxiliary contact module, max. closing delay (mS) — — — 70 70 � Making and breaking conditions to DC13, time constant as stated. � Smoothed DC or three-phase bridge rectifier. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-12 XT IEC Power Control March 2009 Relays and Timers Control Relays Component lifespan (operations) Component lifespan (operations) I = Rated operational current I = Rated operational current e e 6 6 10 10 34 20 20 10 10 5 5 2 2 1 1 DC-13 0.5 0.5 24 V AC-15 0.2 0.2 L = 50 ms 240 V R 0.1 0.1 0.02 0.05 0.5 10 A 0.01 0.02 0.05 0.1 0.2 0.515 2 10 A 0.01 0.1 0.2 15 2 I I e e � Figure 34-1. XTRE (AC-15) Characteristic Curve Figure 34-2. XTRE (DC-13) Characteristic Curve � Making and breaking conditions to DC-13, time constant as stated. The diagrams show the closing and opening travel of the contact of the contactor relays and auxiliary contacts at no load. Tolerances are not taken into consideration. XTRE_ — AC Operation XTRE — DC Operation Normally open contact Normally open contact 0 3.3 4.5 0 2.1 2.9 Normally closed contact Normally closed contact 0 1.0 4.5 0 0.7 2.9 XTCEXFAC_ — AC Operation XTCEXFAC_ — DC Operation Normally open contact Normally open contact 0 3.2 4.5 0 2.3 2.9 Normally closed contact Normally closed contact 0 1.6 4.5 0 0.7 2.9 XTCEXFALC_ — AC Operation XTCEXFALC_ — DC Operation Normally open contact (early make) Normally open contact (early make) 0 2.0 4.5 0 1.1 2.9 Normally closed contact (late make) Normally closed contact (late make) 0 2.8 4.5 0 1.9 2.9 Figure 34-3. Contact Travel Diagrams — XTRE For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-13 XT IEC Power Control March 2009 Relays and Timers Flow Diagrams — Electronic Dimensions Timers Mini Contactor Relays XTMT Mini Timers 5.5 [.22] A1-A2 15-18 t 34 58 LED [2.28] Figure 34-4. On-Delayed 45 [1.77] 52 – 54 [2.05] – [2.13] A1-A2 15-18 Figure 34-10. Mini Control Relay XTRM — OFF ON OFF Approximate Dimensions in mm [in.] LED Figure 34-5. ON-OFF Function 43 [1.69] A1-A2 15-18 58 45 t [2.28] [1.77] LED Figure 34-6. Fleeting Contact on Energization 45 65.3 [1.77] [2.57] Figure 34-11. XTRM Mini Control Relay with A1-A2 IP40 XTMCX Shroud — Approximate 15-18 Dimensions in mm [in.] tt t t LED Figure 34-7. Flashing, Pulse Initiating 62.5 [2.46] A1-A2 15-18 45 t 0.5 s 52 – 54 [1.77] [2.05] – [2.13] LED Figure 34-12. XTRM Mini Control Relay with RC or Varistor Suppressor — Approximate Figure 34-8. Pulse Generating Dimensions in mm [in.] Star-Delta (Wye-Delta) Timer M4 A1-A2 17-18 17-28 ttu 58 50 Power LED [2.28] [1.97] LED LED 45 83 – 86 35 [1.77] [3.27] – [3.39] [1.38] Figure 34-9. Star-Delta Rating Data Figure 34-13. XTRM Mini Control Relay with XTMCXFA Auxiliary Contact — Approximate Dimensions in mm [in.] Table 34-21. Rating Data for Approved Types Pilot Duty General Use Control Relays — XTMR A600, P300 10A – 600V AC 0.5A – 250V DC Timers — XTMT, XTTR B300 6A – 250V AC CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-14 XT IEC Power Control March 2009 Relays and Timers Control Relays 68 45 18 34 68 45 [2.68] [1.77] [.71] [2.68] [1.77] 18 6.5 [.71] [.26] 6.5 90 [.26] 45 75 [3.54] 75 [1.77] [2.95] 117 [2.95] [4.61] Figure 34-14. Control Relay XTRE with XTCEXFA Auxiliary Contact — Figure 34-17. Control Relays XTRE with XTCEXMLB Mechanical Approximate Dimensions in mm [in.] Interlock — Approximate Dimensions in mm [in.] Approx. 28 32 [1.26] [1.10] 68 52.3 26.4 [2.68] [2.06] [1.04] 25.9 [1.02] 36 6.5 [1.42] [.26] 75 45 9 19.2 [2.95] [1.77] [.35] [.76] 125 [4.92] 25 [.98] Figure 34-15. Control Relay with Spring Cage Terminals Figure 34-18. Coil Suppressors for Use with XTRE Control Relays — XTREC with XTCEXFA Auxiliary Contact — Approximate Dimensions in mm [in.] Approximate Dimensions in mm [in.] 25 38 [.98] [1.50] 45 70 [1.77] [2.76] Figure 34-16. Electronic Timer Module XTCEXTE — Approximate Dimensions in mm [in.] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-15 XT IEC Power Control March 2009 Miniature Controls Contents Application Description Standards and Certifications Description Page Due to its compact size, the XT line ■ IEC EN 60947 of mini controls is best suited to be ■ CE Approved Catalog Number applied in light duty loads such as Selection . . . . . . . . . . . . . . . . 34-16 ■ UL hoisting, packaging, material handling, Product Selection . . . . . . . . . . 34-17 ■ CSA heating, lighting and automation ■ ATEX Non-reversing systems. XT mini contactors are a 34 Mini Contactors . . . . . . . . 34-17 particularly compact, economic and ■ CCC environmentally friendly solution Reversing Mini wherever control of small motors or Contactors . . . . . . . . . . . . 34-17 loads is required. Star-Delta (Wye-Delta) Miniature Contactors . . . 34-19 Instructional Leaflets Features Overload Relays . . . . . . . . . 34-20 Accessories . . . . . . . . . . . . . . . 34-21 Pub51219 Inside of Packaging Mini Contactors — Types XTMC Technical Data and XTMC, XTMF Mini and XTMF, 6 – 9A Specifications . . . . . . . . . . . . 34-24 Contactors, XTRM ■ AC Control from 12V to 550V 50 Hz, Dimensions . . . . . . . . . . . . . . . 34-29 Mini Control Relay and 600V 60 Hz Accessories Reference Data . . . . . . . . . . . . 34-210 ■ DC Control from 12V to 220V Pub51243 Inside of Packaging ■ Available with screw or spring cage terminals XTOM Mini Overload ■ Reversing or Non-reversing Relays ■ 3 and 4-Pole Configurations Pub51206 Mini Reversing Link ❑ 3-Pole XTMC Kits ❑ 4-Pole XTMF MN03402002E XTOM Mini Overload Relays Installation and ■ Panel or DIN rail mounting User Manual ■ IP20 finger and back-of-hand proof ■ Low noise operation ■ High degree of climatic proofing ■ Large ambient temperature range -25° to 50°C [-13° to 122°F] XTMC Mini Contactor Mini Overload Relays — Bimetallic Type XTOM Product Description ■ Phase failure sensitivity ® Eaton’s new line of Cutler-Hammer ■ Direct mount to XTMC and XTMF XT Miniature Controls includes non- Mini Contactors reversing and reversing mini contactors, ■ Trip Class 10 mini overload relays and snap-on ■ 11 settings to cover 0.1 to 12A accessories. A wide range of applica- ■ Ambient temperature compensated tions is possible including small -5° to 50°C [23° to 122°F] electrical motors from fractional to ■ Manual and automatic reset by 5 hp (460V AC) or up to 4 kW selector switch (400V AC). ■ 1 Make (NO) or 1 Break (NC) auxil- iary contact as standard ■ Test/Off Button ■ Trip-free release CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-16 XT IEC Power Control March 2009 Miniature Controls Catalog Number Selection Table 34-22. XT IEC Miniature Contactors — Catalog Numbering System X T M C C 6 A 1 0 A Coil Codes Designation 34 A = 110V 50 Hz, 120V 60 Hz N = 400V 50 Hz XT = XT IEC Power Control B = 220V 50 Hz, 240V 60 Hz P = 380V 60 Hz F = 230V 50 Hz R = 12V 50/60 Hz T = 24V 50/60 Hz U = 24V 50 Hz Type TD = 24V DC W = 42V 50 Hz, 48V 60 Hz MC = 3-Pole FVNR Mini IEC Contactor C = 415V 50 Hz, 480V 60 Hz Y = 48V 50 Hz MF = 4-Pole FVNR Mini IEC Contactor D = 550V 50 Hz, 600V 60 Hz AD = 120V DC MR = 3-Pole FVR Mini IEC Contactor E = 208V 60 Hz BD = 220V DC G = 190V 50 Hz, 220V 60 Hz RD = 12V DC H = 240V 50 Hz, 277V 60 Hz WD = 48V DC Terminations L = 380V 50 Hz, 440V 60 Hz Blank Screw Terminals = Spring Cage Terminals C = Integral Auxiliary Contact 01 = 1NC Current Rating, AC-3 10 = 1NO XTMC 6 = 6.6A Frame Size 9 = 8.8A A = 45 mm Mini XTMF 9 = 8.8A Table 34-23. XT IEC Miniature Overload Relays — Catalog Numbering System X T O M P 1 6 A C 1 Trip Class Designation C1 = Class 10A XT = XT IEC Power Control Frame Size Type A = 45 mm Mini OM = Mini Overload Relay Overload Release P16 = 0.1 – 0.16A P24 = 0.16 – 0.24A P40 = 0.24 – 0.4A P60 = 0.4 – 0.6A 001 = 0.6 – 1A 1P6 = 1 – 1.6A 2P4 = 1.6 – 2.4A 004 = 2.4 – 4A 006 = 4 – 6A 009 = 6 – 9A 012 = 9 – 12A For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-17 XT IEC Power Control March 2009 Miniature Controls Product Selection Non-reversing Mini Contactors 34 Table 34-24. Full Voltage Non-reversing Contactors � Opera- Conven- Maximum Maximum Three-phase Motor Rating No. of Aux. Catalog Number Price tional tional kW Ratings AC-3 Power Con- U.S. $ Current Free Air Poles tacts 3-Phase Motors 1-Phase 3-Phase Screw Spring Cage AC-3 Amp Thermal 50 – 60 Hz Horsepower Ratings Horsepower Ratings Terminals Terminals Rating Current 220 – 380 – 550V 660/ 115V 200V 230V 200V 230V 460V 575V AC DC 380/400V AC-1 at 240V 400V 690V Coil Coil 50°C 6.6 20 1.5 3 3 3 1/4 3/4 1 1-1/22333 1NO XTMC6A10_ XTMCC6A10_ 6.6 20 1.5 3 3 3 1/4 3/4 1 1-1/22333 1NC XTMC6A01_ XTMCC6A01_ 8.8 20 2.2 4 4 4 1/2 1 1-1/223553 1NO XTMC9A10_ XTMCC9A10_ 8.8 20 2.2 4 4 4 1/2 1 1-1/223553 1NC XTMC9A01_ XTMCC9A01_ 8.8 20 2.2 4 4 4 1/2 1 1-1/223554 — XTMF9A00_ — � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-26. Reversing Mini Contactors Table 34-25. Full Voltage Reversing Contactors Opera- Conven- Maximum Maximum 3-Phase Spare Auxiliary Catalog Price �� tional tional kW Ratings AC-3 Current Motor Rating Contacts Number U.S. $ Current Free Air 3-Phase Motors 50 – 60 Hz 1-Phase hp Ratings 3-Phase hp Ratings K1M K2M AC-3 Amp Thermal 220/ 380/ 500V 660/ 115V 200V 230V 200V 230V 460V 575V AC DC Rating Current 230/ 400/ 690V 380/400V AC-1 at 240V 440V 50°C 6.6 20 1.5 333 1/4 3/4 1 1-1/2 2 3 3 XTMR6A21_ 63 63 64 64 8.8 20 2.2 444 1/2 1 1-1/22355 XTMR9A21_ 63 63 64 64 � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-26. � The factory installed reversing mini contactor includes (2) XTMC…01 Contactors, (2) XTMCXFA20 2NO Front Mount Auxiliary Contacts (1) XTMCXRL Reversing Link Kit and (1) XTMCXML Mechanical Interlock. Overload Relays . . . . . . . . . . . . . . . . . . Page 34-20 Accessories . . . . . . . . . . . . . . . . . . . . . . Page 34-21 Dimensions . . . . . . . . . . . . . . . . . . . . . . Page 34-29 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-18 XT IEC Power Control March 2009 Miniature Controls Table 34-26. Magnet Coil Suffix Coil Voltage Suffix Coil Voltage Suffix Coil Voltage Suffix Coil Voltage Suffix � Code Code Code Code 110V 50 Hz, 120V 60 Hz A 415V 50 Hz, 480V 60 Hz C 400V 50 Hz N 120V DC AD 220V 50 Hz, 240V 60 Hz B 550V 50 Hz, 600V 60 Hz D 380V 60 Hz P 220V DC BD 230V 50 Hz F 208V 60 Hz E 12V 50/60 Hz R 12V DC RD 24V 50/60 Hz T 190V 50 Hz, 220V 60 Hz G 24V 50 Hz U 48V DC WD 34 � 24V DC TD 240V 50 Hz, 277V 60 Hz H 42V 50 Hz, 48V 60 Hz W—— — — 380V 50 Hz, 440V 60 Hz L 48V 50 Hz Y—— � With DC Operation: Integrated diode resistor combination, coil rating 2.6W. Notes: IEC Utilization Categories, see Page 34-210, 21 Reference Data. 0 22 AC-1: Non-inductive or slightly inductive 22 1 3 5 1 3 5 loads. 21 II 22 21 K1M K2M AC-3: Squirrel-cage motors — starting, 53 2 4 6 2 4 6 switching of motors during running. 54 I 53 54 AC-4: Squirrel-cage motors — starting, 54 54 K1M plugging, inching. K2M 53 53 22 22 K1M U V W K2M 21 21 M A1 K2M A1 M1 3 K1M A2 A2 Figure 34-20. XTMR Reversing Contactor Figure 34-19. XTMR Reversing Contactor Power Wiring Diagram Control Wiring Diagram For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-19 XT IEC Power Control March 2009 Miniature Controls Star-Delta (Wye-Delta) Miniature Contactors 34 � Table 34-27. Star-Delta (Wye-Delta) Miniature Contactor Configuration Maximum kW Ratings AC-3 Maximum 3-Phase Current Motor Rating Max. Spare Components Changeover Auxiliary 3-Phase Motors 50 – 60 Hz 1-Phase hp Ratings 3-Phase hp Ratings Description Catalog � Time (sec.) Contacts Number 220/230/ 380/400/ 500V 115V 200V 230V 200V 230V 460V 575V K1M 240V 440V 4 5.5 5.5 1/2 1 1-1/2 2 3 5 7-1/2 30 K1M Main XTMC9A10_ 21 31 53 Contactor 22 32 54 K1M Auxiliary XTMCXFC22 Contact K5M Delta XTMC9A01_ Contactor K3M Star XTMC9A10_ Contactor K3M Auxiliary XTMCXFC02 Contact K1T Timing XTTR6A60S51B Relay � Operating Frequency: 30 Starts/hour � Underscore (_) indicates magnet coil suffix required. See Table 34-29. Table 34-28. Mini Overload Relay Settings (A) Setting Starting B A: I x 0.58 ≤ 15 sec N Motor Protection in the Y and Delta 1 3 5 1 3 5 Configurations. 1 35 K1M K5M K3M B: I x 1 15 – 40 sec N 2 4 6 2 4 6 2 4 6 Only partial motor protection in star position A C C: I x 0.58 > 40 sec N Motor not protected in star position. Timing Relay set to approximately 10 sec. U1 V2 M1 V1 W2 U2 W1 3 M1 Figure 34-21. Star-Delta (Wye-Delta) Power Wiring Diagram Note: Depending on the coordination type required (i.e. Type 1 or Type 2) it must be established whether the fuse protection and the input wiring for the main and delta contactors are to be common or separate. Table 34-29. Magnet Coil Suffix Coil Voltage Suffix Coil Voltage Suffix Coil Voltage Suffix Coil Voltage Suffix � Code Code Code Code 110V 50 Hz, 120V 60 Hz A 415V 50 Hz, 480V 60 Hz C 400V 50 Hz N 120V DC AD 220V 50 Hz, 240V 60 Hz B 550V 50 Hz, 600V 60 Hz D 380V 60 Hz P 220V DC BD 230V 50 Hz F 208V 60 Hz E 12V 50/60 Hz R 12V DC RD 24V 50/60 Hz T 190V 50 Hz, 220V 60 Hz G 24V 50 Hz U 48V DC WD � 24V DC TD 240V 50 Hz, 277V 60 Hz H 42V 50 Hz, 48V 60 Hz W—— — — 380V 50 Hz, 440V 60 Hz L 48V 50 Hz Y—— � With DC Operation: Integrated diode resistor combination, coil rating 2.6W. Overload Relays . . . . . . . . . . . . . . . . . . Page 34-20 Accessories . . . . . . . . . . . . . . . . . . . . . . Page 34-21 Dimensions . . . . . . . . . . . . . . . . . . . . . . Page 34-29 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-20 XT IEC Power Control March 2009 Miniature Controls Overload Relays 34 �� Table 34-30. Mini Overload Relays Overload Trip Contact Contact Short Circuit Protection (A) Catalog Price Release I Class Sequence Configuration Number U.S. $ t Type 1 Type 2 Circuit CEC/NEC Coordination, Coordination, Breaker Fuse gG/gL gG/gL 0.1 – 0.16A 10A 1NO-1NC 20 0.5 15 — XTOMP16AC1 97 95 0.16 – 0.24A 20 1 15 — XTOMP24AC1 0.24 – 0.4A 20 2 15 — XTOMP40AC1 0.4 – 0.6A 20 2 15 — XTOMP60AC1 29 4 6896 0.6 – 1A 10A 1NO-1NC 20 4 15 3 XTOM001AC1 1 – 1.6A 20 6 15 6 XTOM1P6AC1 1.6 – 2.4A 20 6 15 6 XTOM2P4AC1 2.4 – 4A 10A 1NO-1NC 20 10 15 15 XTOM004AC1 4 – 6A 20 10 15 20 XTOM006AC1 6 – 9A 20 10 15 35 XTOM009AC1 9 – 12A — — — 45 XTOM012AC1 � Short-circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. See MN03402002E for more information. � When fitted directly to the contactor, a clearance of at least 5 mm is required between the overload relays. Tripping Characteristics Chart 2h These tripping characteristics are mean values of the spread 100 XTOM at 20°C ambient temperature in a cold state. Tripping time 60 depends on response current. With devices at operating tem- 40 perature, the tripping time of the overload relay reduces to 20 approx. 25% of the read off value. Specific characteristics for each individual setting range can be found on Page 34-28. 10 6 4 2 1 40 3-Phase 20 10 6 4 2-Phase 2 1 0.6 1 1.5 2 3 4 68 10 15 20 x Setting Current Figure 34-22. Tripping Characteristics Dimensions . . . . . . . . . . . . . . . . . . . . . . Page 34-29 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E Seconds Minutes IEC Contactors & Starters 34-21 XT IEC Power Control March 2009 Miniature Controls Accessories Auxiliary Contacts Front mounted snap-on auxiliary contacts for mini contactors are available with screw or spring cage terminals in a variety of contact configurations. Auxiliary contact modules are standard with interlocked opposing contacts, except in the case of early- make or late-break contacts. Table 34-31. Front Mount Auxiliary Contacts for Use with Mini Contactors 34 Conventional Free Air Contact Contact Package Catalog Number Price � Thermal Current, Configuration Sequence Qty. U.S. $ Screw Spring Cage I = I , AC-1 in Amps Terminals Terminals th e 10 2NC 5 XTMCXFC02 — 21 31 22 32 10 1NO-1NC 5 XTMCXFD11 XTMCXFDC11 21 33 22 34 10 2NO-2NC 5 XTMCXFC22 XTMCXFCC22 21 31 43 53 22 32 44 54 10 2NC 5 XTMCXFA02 — 51 61 52 62 10 1NO-1NC 5 XTMCXFA11 XTMCXFAC11 53 61 54 62 10 2NO 5 XTMCXFA20 — 63 53 54 64 � 10 1NO -1NC 5 XTMCXFAL11 — E L 57 65 58 66 10 4NC 5 XTMCXFA04 XTMCXFAC04 51 61 71 81 52 62 72 82 10 1NO-3NC 5 XTMCXFA13 XTMCXFAC13 53 61 71 81 54 62 72 82 10 2NO-2NC 5 XTMCXFA22 XTMCXFAC22 53 61 71 83 54 62 72 84 10 3NO-1NC 5 XTMCXFA31 XTMCXFAC31 53 61 73 83 54 62 74 84 10 4NO 5 XTMCXFA40 XTMCXFAC40 53 63 73 83 54 64 74 84 � � 10 1NO-1NC 5 XTMCXFAL22 XTMCXFCLC22 57 65 71 83 1N O -1NC E L 58 66 72 84 � Orders must be placed in multiples of package quantity listed. � 1 early-make contact (NO ), 1 late-break contact (NC ). E L Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-22 XT IEC Power Control March 2009 Miniature Controls RC Suppressor Mechanical Interlock 34 Table 34-34. Mechanical Interlock Description Package Catalog Price � Qty. Number U.S. $ � Table 34-32. RC Suppressor Mechanical Interlock 5 XTMCXML Voltage For Use Circuit Package Catalog Price � � with… Symbol Qty. Number U.S. $ Orders must be placed in multiples of package quantity listed. Note: 24 – 48 XTMC6A…, 10 XTMCXRSW A1 ■ For two contactors with AC or DC operated magnet system that are XTMC9A… horizontally or vertically mounted, the distance between contactors is 6 48 – 130 XTMC6A…, 10 XTMCXRSA 0 mm, and the mechanical lifespan is 2.5 x 10 operations. XTMC9A… A2 110 – 250 XTMC6A…, 10 XTMCXRSB Reversing Link Kit XTMC9A… 24 – 48 XTMCC6A…, 10 XTMCXRSCW XTMCC9A… 48 – 130 XTMCC6A…, 10 XTMCXRSCA XTMCC9A… 110 – 250 XTMCC6A…, 10 XTMCXRSCB XTMCC9A… � For AC operated contactors, 50/60 Hz. Note drop-out delay. � Orders must be placed in multiples of package quantity listed. Table 34-35. Reversing Link Kit Description Package Catalog Price Varistor Suppressor Qty. Number U.S. $ Main current wiring for 1 XTMCXRL reversing contactors and starters. Notes: ■ The following control cables are integrated as part of the electrical interlock: K1M: A1 — K2M: 21; K1M: 21 — K2M: A1 ■ Reversing Link Kit does not include mechanical interlock. See Table 34- 34 for Mechanical Interlock. � Table 34-33. Varistor Suppressor Star-Delta (Wye-Delta) Link Kit Voltage For Use Circuit Package Catalog Price � with… Symbol Qty. Number U.S. $ 24 – 48 XTMC6A…, 10 XTMCXVSW A1 XTMC9A… 48 – 130 XTMC6A…, 10 XTMCXVSA XTMC9A… A2 110 – 250 XTMC6A…, 10 XTMCXVSB XTMC9A… 380 – 415 XTMC6A…, 10 XTMCXVSN Table 34-36. Star-Delta (Wye-Delta) Link Kit XTMC9A… Description Package Catalog Price 24 – 48 XTMCC6A…, 10 XTMCXVSCW Qty. Number U.S. $ XTMCC9A… 48 – 130 XTMCC6A…, 10 XTMCXVSCA Main current wiring for star-delta 1 XTMCXSDL XTMCC9A… (wye-delta) combinations. 110 – 250 XTMCC6A…, 10 XTMCXVSCB Includes the Star-Delta Bridge. XTMCC9A… Notes: � For AC operated contactors, 50/60 Hz. DC operated contactors have ■ The following control cables are integrated in addition to the electrical integrated varistor suppressors. interlock: � Orders must be placed in multiples of package quantity listed. K3M: A1 — K5M: 21; K3M: 21 — K5M: A1; K3M: A2 — K5M: A2 ■ When combined with overload relay use separate mounting. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-23 XT IEC Power Control March 2009 Miniature Controls Star-Delta (Wye-Delta) Bridge Connector Table 34-37. Star-Delta (Wye-Delta) Bridge Table 34-39. Connector Contact Sequence Package Catalog Price � Qty. Number U.S. $ 34 Description Package Catalog Price � Qty. Number U.S. $ � 20 XTMCXSDB � For mechanically arranging 50 XTMCXCN contactors and timing relays in combinations. � Orders must be placed in multiples of package quantity listed. � Orders must be placed in multiples of package quantity listed. � Protected against direct contact in accordance with IEC 536. � 0 mm distance between contactors. Paralleling Link Set for Main Contacts IP40 Sealable Transparent Shroud Table 34-38. Paralleling Link Set for Main Contacts Contact Sequence Package Catalog Price � Qty. Number U.S. $ Table 34-40. IP40 Sealable Transparent Shroud ��� 5 XTMCXPLK Description Package Catalog Price Qty. Number U.S. $ IP40 Sealable Transparent 1 XTMCXSHROUD Shroud, snap fitting on mini � Orders must be placed in multiples of package quantity listed. contactor. � Protected against direct contact in accordance with IEC 536. � 4th pole can be broken off: 4-pole: I = 60A; 3-pole: I = 50A th th � AC-1 current carrying capacity of the open contactor increases by a factor of 2.5. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com A1 A2 IEC Contactors & Starters 34-24 XT IEC Power Control March 2009 Miniature Controls Technical Data and Specifications Table 34-41. XT Miniature Controls — General Specifications Description XTMC6A… XTMC9A… XTMF9A… AC Coils DC Coils AC Coils DC Coils AC Coils DC Coils Physical and Electrical (Continued) Standards IEC/EN 60947, VDE 0660, CSA, UL, CCC 34 Weights in kg [lb] 0.2 [0.44] 0.17 [0.37] 0.2 [0.44] 0.17 [0.34] 0.2 [0.44] 0.17 [0.37] Mechanical Life — Operations 10,000,000 20,000,000 10,000,000 20,000,000 20,000,000 — Mechanical Life — Coil @ 50 Hz 7 — 7 — 7 — Maximum mechanical operating frequency (ops/hr) 9000 Insulation Voltage (U ) VAC 690 690 690 690 690 690 i Impulse Withstand Voltage (U ) VAC 6000 6000 6000 6000 6000 6000 imp Operational Voltage (U ) VAC 690 690 690 690 690 690 e Safe Isolation to VDE 0106 Part 101 and Part 101/A1 between coil and contacts (VAC) 300 300 300 300 300 300 between contacts (VAC) 300 300 300 300 300 300 Making Capacity (amps) 110 110 110 110 110 110 Breaking Capacity (amps) 220/230V 90 90 90 90 90 90 380/400V 90 90 90 90 90 90 500V 64 64 64 64 64 64 660/690V 54 54 54 54 54 54 Short-Circuit Protection rating maximum fuse (gL/gG) Type 2 Coordination (A) 10 10 10 10 10 10 Type 1 Coordination (A) 20 20 20 20 20 20 Degree of Protection IP20 Protection against direct contact when actuated from Finger- and back-of-hand proof front (IEC 536) Terminal Capacity of main and auxiliary contacts 2 Solid (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 1.5) 1 x (0.75 – 1.5) 1 x (0.75 – 1.5) 1 x (0.75 – 1.5) 1 x (0.75 – 1.5) 1 x (0.75 – 1.5) 2 x (0.75 – 1.5) 2 x (0.75 – 1.5) 2 x (0.75 – 1.5) 2 x (0.75 – 1.5) 2 x (0.75 – 1.5) 2 x (0.75 – 1.5) Solid or Stranded (AWG) 18-14 18-14 18-14 18-14 18-14 18-14 Terminal Screw M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 Pozidriv screwdriver Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Standard screwdriver (mm) 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 1 x 6 1 x 6 1 x 6 1 x 6 1 x 6 1 x 6 Max. Tightening Torque Nm 1.2 1.2 1.2 1.2 1.2 1.2 Lb-in 10.6 10.6 10.6 10.6 10.6 10.6 Terminal Capacity of spring cage main terminals 2 Solid (mm ) 1 x (1 – 2.5) 1 x (1 – 2.5) 1 x (1 – 2.5) 1 x (1 – 2.5) 1 x (1 – 2.5) 1 x (1 – 2.5) 2 x (1 – 2.5) 2 x (1 – 2.5) 2 x (1 – 2.5) 2 x (1 – 2.5) 2 x (1 – 2.5) 2 x (1 – 2.5) 2 Flexible with ferrule (mm ) 1 x (1 – 2.5) 1 x (1 – 2.5) 1 x (1 – 2.5) 1 x (1 – 2.5) 1 x (1 – 2.5) 1 x (1 – 2.5) 2 x (1 – 2.5) 2 x (1 – 2.5) 2 x (1 – 2.5) 2 x (1 – 2.5) 2 x (1 – 2.5) 2 x (1 – 2.5) Standard screwdriver (mm) 0.6 x 3.5 0.6 x 3.5 0.6 x 3.5 0.6 x 3.5 0.6 x 3.5 0.6 x 3.5 Mounting Position As required, except vertical with terminals A1/A2 at the bottom Environmental Ambient Temperature -25° to 50°C [-13° to 122°F] Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms Contactor without auxiliary contact module Main contact — make contact 10g 10g 10g 10g 10g 10g Main contact — break/make contact 10/8g 10/8g 10/8g 10/8g — — Contactor with auxiliary contact module Main contact — make contact 10g 10g 10g 10g 10g 10g Main contact — make/break contact 20/20g 20/20g 20/20g 20/20g 20/20g 20/20g Climatic Proofing Damp heat, constant, to IEC 60 068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 Pollution Degree III/3 III/3 III/3 III/3 III/3 III/3 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-25 XT IEC Power Control March 2009 Miniature Controls Table 34-42. XT Miniature Controls — Magnet Systems Description XTMC6A… XTMC9A… XTMF9A… AC Coils DC Coils AC Coils DC Coils AC Coils DC Coils Voltage Tolerance Pick-Up (x U ) c Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz 0.8 – 1.1 — 0.8 – 1.1 — 0.8 – 1.1 — Dual frequency coil 50/60 Hz 0.85 – 1.1 — 0.85 – 1.1 — 0.85 – 1.1 — � DC operated — 0.8 – 1.1 — 0.8 – 1.1 — 0.85 – 1.1 34 Power Consumption AC Operation Pick-Up VA Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz 25 — 25 — 25 — Dual frequency coil 50/60 Hz at 50 Hz 30 — 30 — 30 — Dual frequency coil 50/60 Hz at 60 Hz 29 — 29 — 29 — Pick-Up W Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz 22 — 22 — 22 — Dual frequency coil 50/60 Hz at 50 Hz 26 — 26 — 26 — Dual frequency coil 50/60 Hz at 60 Hz 24 — 24 — 24 — Sealing VA Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz 4.6 — 4.6 — 4.6 — Dual frequency coil 50/60 Hz at 50 Hz 5.4 — 5.4 — 5.4 — Dual frequency coil 50/60 Hz at 60 Hz 3.9 — 3.9 — 3.9 — Sealing W Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz 1.3 — 1.3 — 1.3 — Dual frequency coil 50/60 Hz at 50 Hz 1.6 — 1.6 — 1.6 — Dual frequency coil 50/60 Hz at 60 Hz 1.1 — 1.1 — 1.1 — � DC operated Power consumption pick-up = sealing (VA/W) — 2.6 — 2.6 — 2.6 Duty Factor (%) 100 100 100 100 100 100 Switching Time at 100% U c Make Contact Closing delay min (mS) 14 26 14 26 14 26 Closing delay max (mS) 21 35 21 35 21 35 Opening delay min (mS) 8 15 8 15 8 15 Opening delay max (mS) 18 25 18 25 18 25 Closing delay with top mounting auxiliary contact (mS) max. 45 max. 70 max. 45 max. 70 max. 45 max. 70 Reversing Contactors Changeover time at 100% U c Min (mS) 16 40 16 40 16 40 Max (mS) 21 50 21 50 21 50 Arcing time at 690V AC (mS) max. 12 max. 12 max. 12 max. 12 max. 12 max. 12 � Smoothed DC or three-phase bridge rectifier. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-26 XT IEC Power Control March 2009 Miniature Controls Table 34-43. XT Miniature Controls Description XTMC6A… XTMC9A… XTMF9A… AC Coils DC Coils AC Coils DC Coils AC Coils DC Coils AC-1 Operation Conventional free air thermal current, 3-pole, 50 – 60 Hz (A) at 40°C (I ) 22 22 22 22 22 22 th at 50°C (I ) 20 20 20 20 20 20 th at 55°C (I ) 19 19 19 19 19 19 th 34 Conventional free air thermal current, 1-pole (I) 5050 5050 6060 th AC-3 Operation � Rated Operational Current, 50/60 Hz (I ) in amperes (A) e 220/230V 6.6 6.6 9.0 9.0 9.0 9.0 240V 6.6 6.6 9.0 9.0 9.0 9.0 380/400V 6.6 6.6 9.0 9.0 9.0 9.0 415V 6.6 6.6 9.0 9.0 9.0 9.0 440V 6.6 6.6 9.0 9.0 9.0 9.0 500V 5 5 6.4 6.4 6.4 6.4 660/690V 3.5 3.5 4.8 4.8 4.8 4.8 Rated power (P) in kilowatts (kW) 220/230V 1.5 1.5 2.2 2.2 2.2 2.2 240V 1.8 1.8 2.5 2.5 2.5 2.5 380/400V 3 3 4 4 4 4 415V 3.1 3.1 4.3 4.3 4.3 4.3 440V 3.3 3.3 4.6 4.6 4.6 4.6 500V 3 3 4 4 4 4 660/690V 3 3 4 4 4 4 AC-4 Operation � Rated Operational Current, 50/60 Hz (I ) in amperes (A) e 220/230V 5 5 6.6 6.6 6.6 6.6 240V 5 5 6.6 6.6 6.6 6.6 380/400V 5 5 6.6 6.6 6.6 6.6 415V 5 5 6.6 6.6 6.6 6.6 440V 5 5 6.6 6.6 6.6 6.6 500V 3.7 3.7 5 5 5 5 660/690V 2.9 2.9 3.4 3.4 3.4 3.4 Rated power (P) in kilowatts (kW) 220/230V 1.1 1.1 1.5 1.5 1.5 1.5 240V 1.3 1.3 1.8 1.8 1.8 1.8 380/400V 2.2 2.2 3 3 3 3 415V 2.3 2.3 3.1 3.1 3.1 3.1 440V 2.4 2.4 3.3 3.3 3.3 3.3 500V 2.2 2.2 3 3 3 3 660/690V 2.2 2.2 3 3 3 3 � At maximum permissible ambient temperature. Table 34-44. XT Miniature Controls Description XTMC6A… XTMC9A… XTMF9A… AC Coils DC Coils AC Coils DC Coils AC Coils DC Coils � DC-1 Operation 12V 20 20 20 20 — — 24V 20 20 20 20 — — 60V 20 20 20 20 — — 110V 20 20 20 20 — — 220V 20 20 20 20 — — � DC-3 Operation 12V 6 6 8 8 — — 24V 6 6 8 8 — — 60V 3 3 4 4 — — 110V 2 2 3 3 — — 220V — — — — 1 1 � DC-4 Operation 12V 1.8 1.8 2.5 2.5 — — 24V 1.8 1.8 2.5 2.5 — — 60V 1.8 1.8 2.5 2.5 — — 110V 1.1 1.1 1.5 1.5 2.5 2.5 220V 0.2 0.2 0.3 0.3 1 1 Current Heat Loss (3- or 4-pole) in watts at I 2 3.5 2 3.5 2.7 4.7 th at I to AC-3/400V 0.3 0.4 0.5 0.7 — — e � Rated operation current (l ) in amperes, at maximum permissible ambient temperature. e For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-27 XT IEC Power Control March 2009 Miniature Controls Table 34-45. XT Miniature Controls — Auxiliary Contacts Description Built-in Add-on Auxiliary Auxiliary XTMC XTMCXF… Interlocked opposing contacts to ZH1/457, including auxiliary Yes Yes contact module Rated impulse withstand voltage, U (VAC) 6000 6000 imp Overvoltage category / pollution degree III/3 III/3 34 Rated insulation voltage, U (VAC) 690 690 i Rated operational voltage, U (VAC) 600 600 e Safe isolation to VDE 0106 Part 101 and Part 101(A) in VAC between coil and auxiliary contacts 300 300 between the auxiliary contacts 300 300 Rated Operational Current AC-15, I e 220/240V 6A 4A 380/415V 3A 2A 500V 1.5A 1.5A DC-13 (Contacts in Series) 1: 24V 2.5A 2.5A 2: 60V 2.5A 2.5A 3: 100V 1.5A 1.5A 3: 220V 0.5A 0.5A Conventional thermal current, I 10A 10A th Control circuit reliability <10-8, < one failure at (at U = 24 VDC, U = 17 V, I = 5.4 mA) 100 million operations e min min Component Lifespan at U = 240V e 6 AC-15, operations x 10 0.2 0.2 DC-13 L/R = 50 mS: 0.15 0.15 6 2 contacts in series at I = 0.5A, operations x 10 e Short Circuit rating without welding Short Circuit protection rating maximum fuse, 500V gG/gL 6A 6A Short Circuit protection rating maximum fuse, 500V fast 10A 10A Current heat loss at conventional free air thermal current I th per contact, W 0.2 0.2 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-28 XT IEC Power Control March 2009 Miniature Controls Electrical Switching Operation Charts Squirrel-cage motors Squirrel-cage motors Operating characteristics Operating characteristics Starting: from rest Jogging, plugging, reversing Stopping: after attaining a full running speed Electrical Characteristics — Electrical Characteristics — Make (NO): 6x rated motor current Make (NO): Up to 6x rated motor current Breaking (NC): 6x rated motor current Breaking (NC): 1x rated motor current 34 AC-3/400V AC-4/400V kW A kW A 22 43 30 58 18.5 36 15 30 22 43 11 18.5 36 23 15 30 7.5 16 11 23 5.5 12 7.5 16 4 8.8 5.5 12 3 6.5 XTMC 9A 4 8.8 XTMC 9A 2.2 5 XTMC 6A 3 6.5 XTMC 6A 1.5 3.5 2.2 5 1.1 2.5 XTMC DC Coil 1.5 3.5 0.8 2 1.1 2.5 0.55 1.6 XTMC AC Coil 2 0.8 0.37 1.2 0.55 1.6 0.25 0.8 0.01 0.04 0.1 0.4 0.75 2 4 6 10 0.01 0.03 0.06 0.2 0.4 1 3 58 0.02 0.06 0.2 0.6 1 3 5 8 0.02 0.04 0.1 0.3 0.6 2 4 6 10 Component lifespan (millions of operations) Component lifespan (millions of operations) Figure 34-23. Normal Switching Duty — AC-3/400V Figure 34-25. Extreme Switching Duty — AC-4/400V 1400 A AC-1/400V AC-1/400V 700 1000 700 500 500 400 350 275 300 160 200 100 150 55 100 35 XTMC 6A 70 XTMC 9A XTMC 6A 20 XTMC 9A 50 40 10 30 7 5 4 20 3 15 2 1 Seconds 237 5 10 20 30 50 70 100 200 300 500 700 900 0.1 0.2 0.3 0.5 0.713 2 5 710 Duration of load 1 min 3 min 10 min Component lifespan (millions of operations) 5 min 15 min Figure 34-24. Switching Duty for Non-motor Loads, 3- & 4-Pole — Figure 34-26. Short Time Loading, 3-Pole — AC-1/400V (time interval AC-1/400V between two loading cycles: 15 minutes) For more information visit: www.eaton.com CA08102001E Rated output of three-phase motors, 50 – 60 Hz Breaking current Rated operational current l 50 – 60 Hz e Short-time current Rated output of three-phase motors, 50 – 60 Hz Rated operational current l 50 – 60 Hz e IEC Contactors & Starters 34-29 XT IEC Power Control March 2009 Miniature Controls Dimensions 5.5 [.22] D M4 58 50 [2.28] [1.97] 34 106 49 [4.17] [1.93] 35 [1.38] 45 32 58 D1 [1.77] [1.26] [2.28] 45 ≥ 5 [.20] XTMC XTMCC [1.77] D 52 [2.05] 54 [2.13] Figure 34-30. Non-reversing Mini Contactor with Overload Relay D1 83 [3.27] 86 [3.39] Figure 34-27. Non-reversing Mini Contactor 62.5 [2.46] 61 [2.40] 45 52 [1.77] [2.05] Figure 34-31. XTMCXRSA, XTMCXVSA Mini Suppressors — Approximate Dimensions in mm [in] 43 [1.69] 180 83 [7.09] [3.27] 58 45 108 [2.28] [1.77] [4.25] Figure 34-28. Star-Delta Starter Combinations 45 69 [1.77] [2.72] Figure 34-32. XTMCXTSA Mini Sealable Shroud — Approximate Dimensions in mm [in] 61 [2.40] 108 [4.25] 58 [2.28] 90 63 90 94 [3.54] [2.48] [3.54] [3.70] Figure 34-29. Reversing Mini Contactor 58 [2.28] 90 94 [3.54] [3.70] Figure 34-33. XTMCXML Mechanical Interlock — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-30 XT IEC Power Control March 2009 Contactors and Starters Contents Features and Benefits Description Page ■ AC control from 12V to 600V 50/60 Hz Contactors and Starters ■ DC control from 12V to 220V Catalog Number ■ Available with screw or spring cage Selection . . . . . . . . . . . . . . . 34-33 terminals Product Selection 34 ■ Reversing or non-reversing contac- Non-reversing Contactors . . 34-34 tors and starters Reversing Contactors . . . . . . 34-37 ■ AC-3 contactor ratings to 1000A and Non-reversing Starters, AC-1 contactor ratings to 2000A Bimetallic Overload . . . . . . 34-39 ■ Non-reversing starters to 650A Reversing Starters, ■ Panel or DIN rail mounting to 65A XT Family of Contactors Bimetallic Overload . . . . . . 34-40 ■ IP20 finger and back-of-hand proof Non-reversing Starters, ■ Large ambient temperature range, C396 Electronic -25 to 50°C [-13 to 122°F] Contactors and Starters Overload. . . . . . . . . . . . . . . . 34-42 ■ AC and DC controlled contactors in Reversing Starters, the same compact frame Product Description C396 Electronic ■ Low power consumption DC coils Overload. . . . . . . . . . . . . . . . 34-42 ■ Built-in NO or NC auxiliary contacts Eaton’s new line of XT Contactors and Star-Delta (Wye-Delta) to 32A Starters includes non-reversing and Starters. . . . . . . . . . . . . . . . . 34-44 reversing contactors, overload relays ■ Plug-in accessories for reduced Accessories . . . . . . . . . . . . . . 34-49 and a variety of related accessories. installation time Because XT meets IEC, UL, CSA, ■ Coil replacement on Frames C – N Renewal Parts . . . . . . . . . . . . . 34-61 CCC and CE standards, it is the perfect (18 – 820A) Technical Data and product solution for IEC applications ■ Contact replacement on Frames Specifications . . . . . . . . . . . 34-62 all over the world. The compact, space D – N (40 – 820A) Dimensions . . . . . . . . . . . . . . 34-91 saving, and easy to install XT line of IEC ■ Integrated suppressor 7 – 150A DC contactors and starters is the efficient Reference Data . . . . . . . . . . . . 34-210 operated contactors and 185 – and effective solution for customer 2000A AC and DC operated applications from 7A to 2000A. contactors Standards and Certifications ■ IEC EN 60947 ■ CE Approved ■ UL ■ CSA ■ CCC ■ ATEX ■ RoHS Note: For Type 2 Coordination, see Page 34-210. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-31 XT IEC Power Control March 2009 Contactors and Starters Table 34-46. Product Identification 1 1 No. Description Page Contactor Up to 150A AC-3 4 1 AC: 34-34 ■ 12 – 600V, 50, 60, 50/60 Hz ■ 0.8 – 1.1 x U c DC: ■ 12 – 250V 34 ■ XTCE…B_ (7 – 15A): 0.8 – 1.1 x U c ■ XTCE…C_ – XTCE…G_ (18 – 150A): 0.7 – 1.2 x U c ■ 24V: 0.7 – 1.3 x U c at 40°C without additional auxiliary contacts Coils for Special Voltages “Safe Isolation” to IEC 536 between coil and contacts Suppressors 2 3 2 ■ RC suppressor 34-55 ■ Varistor suppressor ■ Free-wheel diode suppressor Overload Relays 3 ■ Can be mounted directly 34-104 4 ■ Separate mounting, 4 possible 4 ■ Protection of EEx e motors 4 Auxiliary Contact Modules 4 4 ■ 2-pole, plug-in type 34-49 ■ 4-pole, plug-in type ■ Overlapping contacts ■ 2-pole, side mounting 1 1 3 3 2 3 4 4 4 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-32 XT IEC Power Control March 2009 Contactors and Starters Table 34-47. XTCE185 – XTCEC20 Contactors No. Description Page XTCE Contactors for 185 – 2000A (AC-3) 1 Multi-Voltage Coils: 34-34 ■ 24 – 48V DC 2 ■ 48 – 110V AC/DC ■ 110 – 250V AC/DC 3 ■ 250 – 500V AC ■ 0.7 – 1.15 x U 34 c Actuation Options: ■ Directly ■ From the PLC ■ With low-consumption contact 1 Minimized pick-up and seal- ing power. XTCS Contactors for 185 – 500A (AC-3) 1 Control Voltages: 34-35 ■ 110 – 120V 50/60 Hz ■ 220 – 240V 50/60 Hz 7 Conventional operation. Cable Terminal Block 2 ■ 1 or 2 conductors per 34-59 phase ■ Round and flat conductor connectable ■ Finger-proof 4 Flat Strip Conductor Terminals 3 ■ 1 or 2 strips per phase 34-59 ■ Control circuit terminal ■ Cover for fingerproofing Mechanical Interlock 4 ■ Fits between contactors 34-57 Overload Relays 5 ■ Can be mounted directly 34-104 ■ Separate mounting, possible 5 ■ Protection of EEx e motors ■ PTB certificate Terminal Shroud 6 6 ■ Finger-proof 34-60 Auxiliary Contact Modules 7 ■ 2-pole, side mounting 34-49 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-33 XT IEC Power Control March 2009 Contactors and Starters Catalog Number Selection Table 34-48. XT IEC Contactors & Starters — Catalog Numbering System X T C E C 0 0 7 B 0 1 A D P 1 6 Designation XTAE, XTAS and XTAR Starters Only — 34 Maximum Overload Relay XT = XT Line of IEC Control XTOB Maximum Overload Rating Type Frame B Frame D P16 = 0.1 – 0.16A 010 = 6 – 10A CE = 3-Pole FVNR IEC Contactor P24 = 0.16 – 0.24A 016 = 10 – 16A CS = 3-Pole FVNR S Series IEC Contactor P40 = 0.24 – 0.4A 024 = 16 – 24A CF = 4-Pole FVNR IEC Contactor 040 = 24 – 40A P60 = 0.4 – 0.6A CR = 3-Pole FVR IEC Contactor 001 = 0.6 – 1A 057 = 40 – 57A CC = IEC Capacitor Contactor 065 = 50 – 65A 1P6 = 1.0 – 1.6A AE = FVNR IEC Starter 075 = 65 – 75A 2P4 = 1.6 – 2.4A AS = FVNR S-Series IEC Starter 004 = 2.4 – 4A Frame F AR = FVR IEC Starter 006 = 4 – 6A 035 = 25 – 35A 010 = 6 – 10A 050 = 35 – 50A 012 = 9 – 12A 070 = 50 – 70A Terminations 016 = 12 – 16A 100 = 70 – 100A Blank = Screw Terminals Frame C Frame G (6 – 65A); 5 mm (80 – 150A); P16 = 0.1 – 0.16A 035 = 25 – 35A No Lugs (185 – 2000A) P24 = 0.16 – 0.24A 050 = 35 – 50A Spring Cage Terminals P40 = 0.24 – 0.4A 070 = 50 – 70A C = (6 – 32A); Spring Cage Coil P60 = 0.4 – 0.6A 100 = 70 – 100A 001 = 0.6 – 1A Terminals Only (185 – 500A) 125 = 95 – 125A 1P6 = 1.0 – 1.6A 150 = 120 – 150A 2P4 = 1.6 – 2.4A 175 = 145 – 175A 004 = 2.4 – 4A Current Ratings, 006 = 4 – 6A Frame L AC-3 Frame Size 010 = 6 – 10A 070 = 50 – 70A Designation 016 = 10 – 16A 100 = 70 – 100A Built-In Auxiliary 024 = 16 – 24A 125 = 95 – 125A Contact 032 = 24 – 32A 160 = 120 – 160A 007 = 7A B = 45 mm 01 = 1NC 220 = 160 – 220A 250 = 200 – 250A 009 = 9A 10 = 1NO 012 = 12A 015 = 15A C396 Maximum Overload Rating 018 = 18A C = 45 mm Suffix 025 = 25A 032 = 32A Std. Class 5/10/20/30 040 = 40A D = 55 mm 00 = 0NO-0NC 050 = 50A S1 = 1NO-1NC Frame B 065 = 65A Side-mount 0.1 – 0.5A = 3EP05 = 3E002 072 = 72A Auxiliary 0.4 – 2.0A 1 – 5A = 3E005 S2 = 2NO-2NC 080 = 80A F = 90 mm = 3E008 1.6 – 8A Side-mount 095 = 95A 6.4 – 32 = 3E032 Auxiliary 115 = 115A G = 90 mm 11 = 1NO-1NC Frame C 150 = 150A Top-mount 0.1 – 0.5A = 3EP05 170 = 170A Auxiliary 0.4 – 2.0A = 3E002 1 – 5A = 3E005 185 = 185A L = 140 mm 22 = 2NO-2NC 1.6 – 8A = 3E008 225 = 225A 6.4 – 32A = 3E032 250 = 250A Frame D 300 = 300A M = 160 mm 6.4 – 32A = 3E032 400 = 400A 9 – 45A = 3E045 500 = 500A 15 – 75A = 3E075 570 = 580A Frame F 580 = 580A N = 250 mm 22 – 110A = 3E110 650 = 650A Frame G 750 = 750A 30 – 150A = 3E150 820 = 820A C10 = 1000A Coil Codes C14 = 1400A, AC-1 P = 260 mm See Table 34-58. C16 = 1600A, AC-3 R = 515 mm C20 = 2000A, AC-1 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-34 XT IEC Power Control March 2009 Contactors and Starters Product Selection Non-reversing Contactors 34 Frame B Frame C Frame D Frame F Frame F Table 34-49. Full Voltage Non-reversing 3-Pole Contactors, Frame B – Frame G UL/CSA Ratings IEC Ratings Aux. Catalog Price Contacts Number — U.S. $ AC-3 AC-1 Maximum kW Ratings AC-3 Screw I (A) (40°C) UL 1-Phase hp Ratings 3-Phase hp Ratings e 3-Phase Motors 50 – 60 Hz AC DC �� Terminals I = I (A) General e th Coil Coil 115V 200V 230V 200V 230V 460V 575V 220/ 380/ 415V 660/ Purpose 230V 400V 690V Amp Rating Frame B 20 1/4 3/4 1 1-1/2 2 3 5 7 22 2.2 3 4 3.5 1NO XTCE007B10_ 20 1/4 3/4 1 1-1/2 2 3 5 7 22 2.2 3 4 3.5 1NC XTCE007B01_ 20 1/2 1 1-1/2 3 3 5 7-1/2 9 22 2.5 4 5.5 4.5 1NO XTCE009B10_ 20 1/2 1 1-1/2 3 3 5 7-1/2 9 22 2.5 4 5.5 4.5 1NC XTCE009B01_ � 20 1 2 2 3 3 10 10 12 22 3.5 5.5 7 6.5 1NO XTCE012B10_ � 20 1 2 2 3 3 10 10 12 22 3.5 5.5 7 6.5 1NC XTCE012B01_ � 20 1 2 3 5 5 10 10 15.5 22 4 7.5 8 7 1NO XTCE015B10_ � 20 1 2 3 5 5 10 10 15.5 22 4 7.5 8 7 1NC XTCE015B01_ Frame C � 40 2 2 3 5 5 10 15 18 40 5 7.5 10 11 1NO XTCE018C10_ � 40 2 2 3 5 5 10 15 18 40 5 7.5 10 11 1NC XTCE018C01_ 40 2 3 5 7-1/2 10 15 20 25 45 7.5 11 14.5 14 1NO XTCE025C10_ 40 2 3 5 7-1/2 10 15 20 25 45 7.5 11 14.5 14 1NC XTCE025C01_ 40 3 5 5 10 10 20 25 32 45 10 15 18 17 1NO XTCE032C10_ 40 3 5 5 10 10 20 25 32 45 10 15 18 17 1NC XTCE032C01_ Frame D 63 3 5 7-1/2 10 15 30 40 40 60 12.5 18.5 24 23 — XTCE040D00_ 63 3 5 7-1/2 10 15 30 40 40 60 12.5 18.5 24 23 1NO-1NC XTCE040DS1_ 80 3 7-1/2 10 15 20 40 50 50 80 15.5 22 30 30 — XTCE050D00_ 80 3 7-1/2 10 15 20 40 50 50 80 15.5 22 30 30 1NO-1NC XTCE050DS1_ 88 5 10 15 20 25 50 60 65 98 20 30 39 35 — XTCE065D00_ 88 5 10 15 20 25 50 60 65 98 20 30 39 35 1NO-1NC XTCE065DS1_ 88 5 10 15 20 25 50 60 72 98 22 37 41 35 — XTCE072D00_ 88 5 10 15 20 25 50 60 72 98 22 37 41 35 1NO-1NC XTCE072DS1_ Frame F 125 7-1/2 15 15 25 30 60 75 80 110 25 37 48 63 — XTCE080F00_ 125 7-1/2 15 15 25 30 60 75 80 110 25 37 48 63 1NO-1NC XTCE080FS1_ 125 7-1/2 15 15 25 40 75 100 95 130 30 45 57 75 — XTCE095F00_ 125 7-1/2 15 15 25 40 75 100 95 130 30 45 57 75 1NO-1NC XTCE095FS1_ Frame G 160 10 25 25 40 50 100 100 115 160 37 55 70 90 — XTCE115G00_ 160 10 25 25 40 50 100 100 115 160 37 55 70 90 1NO-1NC XTCE115GS1_ 180 10 25 30 40 60 125 125 150 190 48 75 91 96 — XTCE150G00_ 180 10 25 30 40 60 125 125 150 190 48 75 91 96 1NO-1NC XTCE150GS1_ � � 225 10 25 30 40 60 125 125 170 275 52 90 100 96 — XTCE170G00_ � � 225 10 25 30 40 60 125 125 170 275 52 90 100 96 1NO-1NC XTCE170GS1_ � Underscore (_) indicates magnet coil suffix Notes: Frame B – C contactors with 1NC built-in required. See Table 34-58, Page 34-38. auxiliary are mirror contacts (XTCE...B01_ – � The 7 – 32A XTCE Contactors have positively For Spring Cage Terminals, insert C after the XTCE...C01_). fourth digit of the Catalog Number. driven contacts between the integrated Example: XTCEC007B10A. For 7 – 12A auxiliary contact and the auxiliary contact XTCEC Contactors, the power, auxiliary and module as well as within the auxiliary coil terminals are spring cage. For 18 – 32A contact modules. XTCEC Contactors, the auxiliary and coil Contact Sequence terminals are spring cage. For 40 – 150A The 40 – 65A XTCE Contactors have positively XTCEC Contactors, the coil terminals only driven contacts within the auxiliary contact (Circuit Symbols) . . . . . . . . . . . . . . . . Page 34-35 are spring cage. module. 6 auxiliary contacts are possible Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-38 � For electrical life contactor application data, with a combination of side mounted and Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-49 see Table 34-51, Page 34-35. front mount auxiliary contacts. Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 � For 180 – 225A, use 2 x 3/0 AWG wire. � 2 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 For 225 – 275A, use 2 x 70 mm wire. DC operated contactors (Frames B – G, Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 7 – 150A) have a built-in suppressor circuit. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-35 XT IEC Power Control March 2009 Contactors and Starters Non-reversing Contactors 34 Frame L Frame M Frame N Frame P Frame R Table 34-50. Full Voltage Non-reversing 3-Pole Contactors, Frame L – Frame R UL/CSA Ratings IEC Ratings Aux. Catalog Price � Contacts Number U.S. $ AC-3 AC-1 Maximum kW I (A) (40°C) Ratings AC-3 e I = I (A) UL General 3-Phase hp Ratings e th 3-Phase Motors 50 – 60 Hz AC DC Purpose Coil Coil 200V 230V 460V 575V 220/ 380/ 415V 660/ 1000V Amp Rating � � 230V 400V 690V Frame L — Standard Coil (110/120V, 230/240V AC Coil Only) 225 50 60 125 150 185 337 55 90 110 175 108 2NO-2NC XTCS185L22_ 250 60 75 150 200 225 386 70 110 132 215 108 2NO-2NC XTCS225L22_ 300 75 100 200 250 250 429 75 132 148 240 108 2NO-2NC XTCS250L22_ Frame L — Electronic Coil 225 50 60 125 150 185 337 55 90 110 175 108 2NO-2NC XTCE185L22_ 250 60 75 150 200 225 386 70 110 132 215 108 2NO-2NC XTCE225L22_ 300 75 100 200 250 250 429 75 132 148 240 108 2NO-2NC XTCE250L22_ Frame M — Standard Coil (110/120V, 230/240V AC Coil Only) 350 100 125 250 300 300 490 90 160 180 286 132 2NO-2NC XTCS300M22_ 450 125 150 300 400 400 612 125 200 240 344 132 2NO-2NC XTCS400M22_ 550 150 200 400 500 500 857 155 250 300 344 132 2NO-2NC XTCS500M22_ 550 150 200 400 500 580 980 155 315 350 344 132 2NO-2NC XTCS570M22_ Frame M — Electronic Coil 350 100 125 250 300 300 490 90 160 180 286 132 2NO-2NC XTCE300M22_ 450 125 150 300 400 400 612 125 200 240 344 132 2NO-2NC XTCE400M22_ 550 150 200 400 500 500 857 155 250 300 344 132 2NO-2NC XTCE500M22_ 550 150 200 400 500 580 980 155 315 350 344 132 2NO-2NC XTCE570M22_ Frame N — Electronic Coil � 630 200 200 400 600 580 980 185 315 348 560 600 2NO-2NC XTCE580N22_ � 700 200 250 500 600 650 1041 205 355 390 630 600 2NO-2NC XTCE650N22_ � 800 250 300 600 700 750 1102 240 400 455 720 800 2NO-2NC XTCE750N22_ � 850 290 350 700 860 820 1225 260 450 500 750 800 2NO-2NC XTCE820N22_ � 1100 350 420 850 980 1000 1225 315 560 610 1000 1000 2NO-2NC XTCEC10N22_ Frame P — Electronic Coil � 1400 — — — — — 1714 — — — — — 2NO-2NC XTCEC14P22_ Frame R — Electronic Coil � 1600 560 640 1200 1300 1600 2200 500 900 900 1600 1700 2NO-2NC XTCEC16R22_ � 2000 — — — — — 2450 — — — — — 2NO-2NC XTCEC20R22_ � Underscore (_) indicates magnet coil suffix required. See Table 34-58, Page 34-38. Terminals not included. See Page 34-59 for terminal accessories. � For 185 – 500A Contactors at 660/690V or 1000V: Do not reverse directly. � When operating the 580 – 2000A XTCE contactors with frequency inverters, the suppressor on the load side must be removed. The load side suppressor must also be removed when performing a high-voltage test — see Pub51204, Pub51209. � Table 34-51. Contactor Application Data Table 34-52. Full Voltage Non-reversing 3-Pole Contactors — Contact Sequence Catalog Electrical Life (Operations) for (Circuit Symbols) — Standard Offering Prefix 10hp, 480V (14.2A) Applications Contactor Auxiliary Contact XTCE012B 1 million Frame Contacts Sequence XTCE015B 1.2 million B – C 1NO A1 1 35 13 XTCE018C 2 million � See Page 34-88 for Electrical Life Curves. A2 2 4 6 14 B – C 1NC A1 1 3 5 21 Note: A2 46 22 AC and DC operated contactors have a 2 built-in suppressor circuit (Frames L – R, D – G — A1 1 3 5 185 – 2000A). Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-38 A2 2 46 Accessories . . . . . . . . . . . . . . . . . . . . Page 34-49 L – R 2NO-2NC Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 A1 1 3 5 13 21 31 43 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 A2 2 46 14 22 32 44 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-36 XT IEC Power Control March 2009 Contactors and Starters Table 34-53. Full Voltage 4-Pole Non-reversing Contactors with Screw Terminals Maximum UL/CSA Motor Rating I (A) Maximum kW Aux. Contact Catalog Price e � Ratings AC-3 Contacts Sequence Number U.S. $ 1-Phase hp 3-Phase hp Ratings AC-3 AC-1 3-Phase Motors 50 – 60 Hz Ratings (40°C) 115V 230V 200V 230V 460V 575V 220/ 380/ 415V 660/ 230V 400V 690V 1 2 3 3 10 10 12 22 3.5 5.5 7 6.5 — XTCF020B00_ 34 — — 7.5 7.5 10 15 18 32 5 7.5 10 11 1NO XTCF032C10_ — — 7.5 10 15 20 25 45 7.5 11 14.5 14 1NO XTCF045C10_ — — 10 15 30 40 40 63 12.5 18.5 24 23 — XTCF063D00_ — — 15 20 40 50 50 80 15.5 22 30 30 — XTCF080D00_ — — 25 30 60 75 80 125 25 37 48 63 — XTCF125G00_ — — 25 40 75 100 95 160 30 45 57 75 — XTCF160G00_ — — 40 50 100 125 115 200 37 55 70 90 — XTCF200G00_ � Underscore (_) indicates magnet coil suffix required. See Table 34-59. Table 34-54. Switching of DC Currents (when necessary cable to be supplied by customer) Description 1-Pole 2-Pole XTCF020B – XTCF200G >60V DC Table 34-55. Controlling XTCS and XTCE Contactors Frame L – R (185 – 2000A) Description XTCS185L – XTCS500M XTCEC16R, XTCEC20R XTCE185L – XTCEC14P Conventional (+) L1 (+) L1 (+) L1 A1/A2 are applied to voltage in the usual manner. (–) N (–) N (–) N � � � A10 A2 A10 A2 A10 A2 A11 A1 A11 A1 A11 A1 A3 TY A3 A3 A4 TX A4 A4 Direct from the PLC — (+) L1 (+) L1 A 24V output from the PLC can be connected directly to connections A3/A4. (–) N (–) N � � A10 A2 A10 A2 A11 A1 A11 A1 TY A3 A3 TX A4 A4 24V 24V GND GND From Low-Consumption Command Devices — (+) L1 (+) L1 Command devices which can only be subject to minimal loads such as circuit (–) N (–) N board relays, control circuit devices or position switches can be connected � � directly to A10/A11. A10 A2 A10 A2 � � A11 A1 A11 A1 TY A3 A3 TX A4 A4 � Standstill in an emergency (Emergency-Stop). � Command device connection, Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-37 XT IEC Power Control March 2009 Contactors and Starters Reversing Contactors 34 Frame B Frame C Frame D Frame F and G Table 34-56. Full Voltage Reversing Contactors with Screw Terminals Maximum 3-Phase Motor Rating I (A) Maximum kW Ratings AC-3 Spare Auxiliary Catalog Price e � Contacts Number U.S. $ 1-Phase hp Ratings 3-Phase hp Ratings AC-3 3-Phase Motors 50 – 60 Hz K1M K2M AC Coil DC Coil 115V 230V 200V 230V 460V 575V 220/ 380/ 415V 660/ 230V 400V 690V Frame B 1/4 1 1-1/2 2 3 5 7 2.2 3 4 3.5 XTCR007B21_ 63 63 64 64 1/2 1-1/2 2 3 5 7-1/2 9 2.5 4 5.5 4.5 XTCR009B21_ 63 63 64 64 1/2 2 3 3 7-1/2 10 12 3.5 5.5 7 6.5 XTCR012B21_ 63 63 64 64 Frame C 2 3 5510 15 18 5 7.5 8 11 XTCR018C21_ 63 63 64 64 2 5 7-1/2 7-1/2 15 20 25 7.5 11 14.5 14 XTCR025C21_ 63 63 64 64 3 5 10 10 20 25 32 10 15 18 17 XTCR032C21_ 63 63 64 64 Frame D 3 7-1/2 10 15 30 40 40 12.5 18.5 24 23 — — XTCR040D11_ 3 10 15 20 40 50 50 15.5 22 30 30 — — XTCR050D11_ 51520 25 50 60 65 20 30 39 35 — — XTCR065D11_ Frame F 7-1/2 15 25 30 60 75 80 25 37 48 63 — — XTCR080F11_ 7-1/2 15 25 40 75 100 95 30 45 57 75 — — XTCR095F11_ Frame G 10 25 40 50 100 100 115 37 55 70 90 — — XTCR115G11_ 15 30 40 60 100 100 150 48 75 91 96 — — XTCR150G11_ � Underscore (_) indicates magnet coil suffix required. See Table 34-58. Table 34-57. XTCR Reversing Contactor Components Qty Frame B C D F G 2 Contactor XTCE...B01_ XTCE...B01_ XTCE...D00_ XTCE...F00_ XTCE...G00_ 2 Auxiliary Contact XTCEXFAC20 XTCEXFAC20 XTCEXFBG11 XTCEXFBG11 XTCEXFBG11 1 Mechanical Interlock XTCEXMLB XTCEXMLC XTCEXMLD XTCEXMLG XTCEXMLG 1 Reversing Link Kit XTCEXRLB XTCEXRLC XTCEXRLD XTCEXRLG XTCEXRLG Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-38 Accessories . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-38 XT IEC Power Control March 2009 Contactors and Starters Table 34-58. Magnet Coil Suffix Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code Frame A – B Frame C – F Frame G 110V 50 Hz, 120V 60 Hz A 110V 50 Hz, 120V 60 Hz A 100 – 120V 50/60 Hz A 220V 50 Hz, 240V 60 Hz B 220V 50 Hz, 240V 60 Hz B 190 – 240V 50/60 Hz B 230V 50 Hz F 230V 50 Hz F 24V 50/60 Hz T 24V 50/60 Hz T 24V 50/60 Hz T 24 – 27V DC TD 34 24V DC TD 24 – 27V DC TD 480 – 500V 50/60 Hz C 415V 50 Hz, 480V 60 Hz C 415V 50 Hz, 480V 60 Hz C 380 – 440V 50/60 Hz L 550V 50 Hz, 600V 60 Hz D 550V 50 Hz, 600V 60 Hz D 42 – 48V 50/60 Hz W 208V 60 Hz E 208V 60 Hz E 110 – 130V DC AD 190V 50 Hz, 220V 60 Hz G 190V 50 Hz, 220V 60 Hz G 200 – 240V DC BD 240V 50 Hz, 277V 60 Hz H 240V 50 Hz, 277V 60 Hz H 48 – 60V DC WD 380V 50 Hz, 440V 60 Hz L 380V 50 Hz, 440V 60 Hz L Frame L – N 400V 50 Hz N 400V 50 Hz N 110 – 250V 40 – 60 Hz/DC A 380V 60 Hz P 380V 60 Hz P 250 – 500V 40 – 60 Hz C 12V 50/60 Hz R 12V 50/60 Hz R 48 – 110V 40 – 60 Hz/DC Y � 24V 50 Hz U 24V 50 Hz U 24 – 48V DC TD 42V 50 Hz, 48V 60 Hz W 42V 50 Hz, 48V 60 Hz W Frame L – M, S-Series 48V 50 Hz Y 48V 50 Hz Y 110 – 120V 50/60 Hz A 120V DC AD 110 – 130V DC AD 220 – 240V 50/60 Hz B 220V DC BD 200 – 240V DC BD Frame P – R � 12V DC RD 12 – 14V DC RD 220 – 250V 50 – 60 Hz/DC B 48V DC WD 48 – 60V DC WD � Frame C – D only. � Frame L – M only. 21 21 0 0 22 22 22 22 21 21 13 5 135 II II 21 22 21 22 K1M 13 14 13 K2M 14 2 4 6 2 4 6 I I 14 13 14 13 14 54 14 54 K1M K2M K1M K2M 53 53 13 13 22 22 22 22 K2M K1M U V W K2M K1M 21 21 21 21 A1 A1 A1 A1 M M1 K1M K2M K1M K2M 3 A2 A2 A2 A2 (-)N 7 – 32A 40 – 150A 7 – 150A with Mechanical Interlock 80 – 150A on Mounting Plate Figure 34-34. 7 – 150A XTCR Reversing Contactor Wiring Diagram Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-39 XT IEC Power Control March 2009 Contactors and Starters Non-reversing Starters, Bimetallic Overload 34 Frame B Frame C Frame D Frame F/G Frame L Table 34-59. Full Voltage Non-reversing 3-Pole Starters with Bimetallic Overload Maximum 3-Phase Motor Rating I (A) Maximum kW Ratings AC-3 Auxiliary Catalog Price e �� Contacts Number U.S. $ 1-Phase hp Ratings 3-Phase hp Ratings AC-3 AC-1 3-Phase Motors 50 – 60 Hz AC Coil DC Coil 115V 230V 200V 230V 460V 575V 220/ 380/ 415V 660/ 1000V 230V 400V 690V Frame B 1/4 1 1-1/2 2 3 5 7 20 2.2 3 4 3.5 — 1NO XTAE007B10_ _ 1/4 1 1-1/2 2 3 5 7 20 2.2 3 4 3.5 — 1NC XTAE007B01_ _ 1/2 1-1/2 3 3 5 7-1/2 9 20 2.5 4 5.5 4.5 — 1NO XTAE009B10_ _ 1/2 1-1/2 3 3 5 7-1/2 9 20 2.5 4 5.5 4.5 — 1NC XTAE009B01_ _ � 1 2 3 3 10 10 12 20 3.5 5.5 7 6.5 — 1NO XTAE012B10_ _ � 1 2 3 3 10 10 12 20 3.5 5.5 7 6.5 — 1NC XTAE012B01_ _ � 1 3 5 5 10 10 15.5 20 4 7.5 8 7 — 1NO XTAE015B10_ _ � 1 3 5 5 10 10 15.5 20 4 7.5 8 7 — 1NC XTAE015B01_ _ Frame C � 2 3 5 5 10 15 18 35 5 7.5 10 11 — 1NO XTAE018C10_ _ � 2 3 5 5 10 15 18 35 5 7.5 10 11 — 1NC XTAE018C01_ _ 2 5 7-1/2 7-1/2 15 20 25 40 7.5 11 14.5 14 — 1NO XTAE025C10_ _ 2 5 7-1/2 7-1/2 15 20 25 40 7.5 11 14.5 14 — 1NC XTAE025C01_ _ 3 5 10 10 20 25 32 40 10 15 18 17 — 1NO XTAE032C10_ _ 3 5 10 10 20 25 32 40 10 15 18 17 — 1NC XTAE032C01_ _ Frame D 3 7-1/2 10 15 30 40 40 50 12.5 18.5 24 23 — — XTAE040D00_ _ 3 10 15 20 40 50 50 60 15.5 22 30 30 — — XTAE050D00_ _ 5 15 20 25 50 60 65 72 20 30 39 35 — — XTAE065D00_ _ Frame F 7-1/2 15 25 30 60 75 80 110 25 37 48 63 — — XTAE080F00_ _ 7-1/2 15 25 40 75 100 95 110 30 45 57 75 — — XTAE095F00_ _ Frame G 10 25 40 50 100 125 115 160 37 55 70 105 — — XTAE115G00_ _ 15 30 40 60 125 125 150 160 48 75 91 125 — — XTAE150G00_ _ Frame L — — 50 60 125 150 185 275 55 90 110 175 108 2NO-2NC XTAE185L22_ _ — — 60 75 150 200 225 315 70 110 132 215 108 2NO-2NC XTAE225L22_ _ — — 75 100 200 250 250 350 75 132 148 240 108 2NO-2NC XTAE250L22_ _ � Underscore (_) indicates magnet coil suffix required. See Table 34-62. � Underscore (_) indicates overload relay suffix required. See Table 34-64. � For electrical life contactor application data see Table 34-63. Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-40 Accessories . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-40 XT IEC Power Control March 2009 Contactors and Starters Table 34-60. Full Voltage Non-reversing S-Series 3-Pole Starters with Bimetallic Overload Maximum 3-Phase Motor Rating I (A) Maximum kW Ratings AC-3 Catalog Price e �� Number U.S. $ 1-Phase hp Ratings 3-Phase hp Ratings AC-3 AC-1 3-Phase Motors 50 – 60 Hz AC Coil DC Coil 115V 230V 200V 230V 460V 575V 220/ 380/ 415V 660/ 1000V 230V 400V 690V Frame L — — 50 60 125 150 185 337 55 90 110 175 108 XTAS185L22_ _ — — 60 75 150 200 225 386 70 110 132 215 108 XTAS225L22_ _ 34 — — 75 100 200 250 250 429 75 132 148 240 108 XTAS250L22_ _ � Underscore (_) indicates magnet coil suffix required. See Table 34-62. � Underscore (_) indicates overload relay suffix required. See Table 34-64. Reversing Starters, Bimetallic Overload Table 34-61. Full Voltage Reversing Starters with Screw Terminals and Bimetallic Overload Maximum 3-Phase Motor Rating I (A) Maximum kW Ratings AC-3 Catalog Price e �� Number U.S. $ 1-Phase hp Ratings 3-Phase hp Ratings AC-3 3-Phase Motors 50 – 60 Hz AC Coil DC Coil 115V 230V 200V 230V 460V 575V 220/ 380/ 415V 660/ 230V 400V 690V Frame B 1/4 1 1-1/2 2 3 5 7 2.2 3 4 3.5 XTAR007B21_ _ 1/2 1-1/2 3 3 5 7-1/2 9 2.5 4 5.5 4.5 XTAR009B21_ _ 1 2 3 3 10 10 12 3.5 5.5 7 6.5 XTAR012B21_ _ Frame C 2 3 5 5 10 15 18 5 7.5 8 11 XTAR018C21_ _ 2 5 7-1/2 7-1/2 15 20 25 7.5 11 14.5 14 XTAR025C21_ _ 3 5 10 10 20 25 32 10 15 18 17 XTAR032C21_ _ Frame D 3 7-1/2 10 15 30 40 40 12.5 18.5 24 23 XTAR040D11_ _ 3 10 15 20 40 50 50 15.5 22 30 30 XTAR050D11_ _ 5 15 20 25 50 60 65 20 30 39 35 XTAR065D11_ _ � Underscore (_) indicates magnet coil suffix required. See Table 34-62. � Underscore (_) indicates overload relay suffix required. See Table 34-64. Table 34-62. Magnet Coil Suffix Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code Frame A – B Frame C – F Frame G 110V 50 Hz, 120V 60 Hz A 110V 50 Hz, 120V 60 Hz A 100 – 120V 50/60 Hz A 220V 50 Hz, 240V 60 Hz B 220V 50 Hz, 240V 60 Hz B 190 – 240V 50/60 Hz B 230V 50 Hz F 230V 50 Hz F 24V 50/60 Hz T 24V 50/60 Hz T 24V 50/60 Hz T 24 – 27V DC TD 24V DC TD 24 – 27V DC TD 480 – 500V 50/60 Hz C 415V 50 Hz, 480V 60 Hz C 415V 50 Hz, 480V 60 Hz C 380 – 440V 50/60 Hz L 550V 50 Hz, 600V 60 Hz D 550V 50 Hz, 600V 60 Hz D 42 – 48V 50/60 Hz W 208V 60 Hz E 208V 60 Hz E 110 – 130V DC AD 190V 50 Hz, 220V 60 Hz G 190V 50 Hz, 220V 60 Hz G 200 – 240V DC BD 240V 50 Hz, 277V 60 Hz H 240V 50 Hz, 277V 60 Hz H 48 – 60V DC WD 380V 50 Hz, 440V 60 Hz L 380V 50 Hz, 440V 60 Hz L Frame L – N 400V 50 Hz N 400V 50 Hz N 110 – 250V 40 – 60 Hz/DC A 380V 60 Hz P 380V 60 Hz P 250 – 500V 40 – 60 Hz C 12V 50/60 Hz R 12V 50/60 Hz R 48 – 110V 40 – 60 Hz/DC Y � 24V 50 Hz U 24V 50 Hz U 24 – 48V DC TD 42V 50 Hz, 48V 60 Hz W 42V 50 Hz, 48V 60 Hz W Frame L – N, S-Series 48V 50 Hz Y 48V 50 Hz Y 110 – 120V 50/60 Hz A 120V DC AD 110 – 130V DC AD 220 – 240V 50/60 Hz B 220V DC BD 200 – 240V DC BD Frame P – R � 12V DC RD 12 – 14V DC RD 220 – 250V 50 – 60 Hz/DC B 48V DC WD 48 – 60V DC WD � Frame C – D only. � Frame L – M only. � Table 34-63. Starter Application Data Catalog Prefix AC-3 Electrical Life (Operations) XTAE012B 12A 1 million XTAE015B 15A 1.2 million XTAE018C 18A 2 million Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-49 � See Page 34-88 for Electrical Life Curves. Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-41 XT IEC Power Control March 2009 Contactors and Starters Table 34-64. XTOB and XTOT Overload Relay Suffix Motor Full Suffix For Use with Overload Relay Motor Full Suffix For Use with Overload Relay Load Code Contactor Catalog Load Code Contactor Catalog Amperes Amp Range Number Amperes Amp Range Number Frame B Frame D 0.1 – 0.16 P16 7 – 15A XTOBP16BC1 6 – 10 010 40 – 72A XTOB010DC1 0.16 – 0.24 P24 7 – 15A XTOBP24BC1 10 – 16 016 40 – 72A XTOB016DC1 0.24 – 0.4 P40 7 – 15A XTOBP40BC1 16 – 24 024 40 – 72A XTOB024DC1 0.4 – 0.6 P60 7 – 15A XTOBP60BC1 34 24 – 40 040 40 – 72A XTOB040DC1 0.6 – 1 001 7 – 15A XTOB001BC1 40 – 57 057 50 – 72A XTOB057DC1 1 – 1.6 1P6 7 – 15A XTOB1P6BC1 50 – 65 065 65 – 72A XTOB065DC1 1.6 – 2.4 2P4 7 – 15A XTOB2P4BC1 65 – 75 075 65 – 72A XTOB075DC1 2.4 – 4 004 7 – 15A XTOB004BC1 Frame F 4 – 6 006 7 – 15A XTOB006BC1 � 25 – 35 035 80 – 95A XTOB055GC1 6 – 10 010 7 – 15A XTOB010BC1 � 35 – 50 050 80 – 95A XTOB050GC1 9 – 12 012 9 – 15A XTOB012BC1 � 50 – 70 070 80 – 95A XTOB070GC1 12 – 16 016 12 – 15A XTOB016BC1 � 70 – 100 100 80 – 95A XTOB100GC1 Frame C Frame G 0.1 – 0.16 P16 18 – 32A XTOBP16CC1 � 25 – 35 035 115 – 170A XTOB055GC1 0.16 – 0.24 P24 18 – 32A XTOBP24CC1 � 35 – 50 050 115 – 170A XTOB050GC1 0.24 – 0.4 P40 18 – 32A XTOBP40CC1 � 50 – 70 070 115 – 170A XTOB070GC1 0.4 – 0.6 P60 18 – 32A XTOBP60CC1 � 70 – 100 100 115 – 170A XTOB100GC1 0.6 – 1 001 18 – 32A XTOB001CC1 � 95 – 125 125 115 – 170A XTOB125GC1 1 – 1.6 1P6 18 – 32A XTOB1P6CC1 � 120 – 150 150 150 – 170A XTOB150GC1 1.6 – 2.4 2P4 18 – 32A XTOB2P4CC1 � 145 – 175 175 150 – 170A XTOB175GC1 2.4 – 4 004 18 – 32A XTOB004CC1 Frame L 4 – 6 006 18 – 32A XTOB006CC1 50 – 70 070 185 – 250A XTOB070LC1 6 – 10 010 18 – 32A XTOB010CC1 70 – 100 100 185 – 250A XTOB100LC1 10 – 16 016 18 – 32A XTOB016CC1 95 – 125 125 185 – 250A XTOB125LC1 16 – 24 024 18 – 32A XTOB024CC1 24 – 32 032 25 – 32A XTOB032CC1 120 – 160 160 185 – 250A XTOB160LC1 160 – 220 220 185 – 250A XTOB220LC1 200 – 250 250 225 – 250A XTOB250LC1 � Catalog Number refers to direct mount overload relay. Add an S to the end of the Catalog Number for separate mount. Overload Relays . . . . . . . . . . . . . . . . Page 34-104 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-42 XT IEC Power Control March 2009 Contactors and Starters Non-reversing Starters, C396 Electronic Overload Frame C XT Starter with C396 Electronic Overload 34 Table 34-65. Full Voltage Non-reversing 3-Pole Starters with C396 Electronic Overload Maximum 3-Phase Motor Rating I (A) Maximum kW Ratings AC-3 Auxiliary Catalog Price e �� Contacts Number U.S. $ 1-Phase hp Ratings 3-Phase hp Ratings AC-3 AC-1 3-Phase Motors 50 – 60 Hz Standard 115V 230V 200V 230V 460V 575V 220/ 380/ 415V 660/ 1000V AC DC 230V 400V 690V Coil Coil Frame B 1/4 1 1-1/2 2 3 5 7 20 2.2 3 4 3.5 — 1NO XTAE007B10_ _ 1/4 1 1-1/2 2 3 5 7 20 2.2 3 4 3.5 — 1NC XTAE007B01_ _ 1/2 1-1/2 3 3 5 7-1/2 9 20 2.5 4 5.5 4.5 — 1NO XTAE009B10_ _ 1/2 1-1/2 3 3 5 7-1/2 9 20 2.5 4 5.5 4.5 — 1NC XTAE009B01_ _ � 1 2 3 3 10 10 12 20 3.5 5.5 7 6.5 — 1NO XTAE012B10_ _ � 1 2 3 3 10 10 12 20 3.5 5.5 7 6.5 — 1NC XTAE012B01_ _ � 1 3 5 5 10 10 15.5 20 4 7.5 8 7 — 1NO XTAE015B10_ _ � 1 3 5 5 10 10 15.5 20 4 7.5 8 7 — 1NC XTAE015B01_ _ Frame C � 2 3 5 5 10 15 18 35 5 7.5 10 11 — 1NO XTAE018C10_ _ � 2 3 5 5 10 15 18 35 5 7.5 10 11 — 1NC XTAE018C01_ _ 2 5 7-1/2 7-1/2 15 20 25 40 7.5 11 14.5 14 — 1NO XTAE025C10_ _ 2 5 7-1/2 7-1/2 15 20 25 40 7.5 11 14.5 14 — 1NC XTAE025C01_ _ 3 5 10 10 20 25 32 40 10 15 18 17 — 1NO XTAE032C10_ _ 3 5 10 10 20 25 32 40 10 15 18 17 — 1NC XTAE032C01_ _ Frame D 3 7-1/2 10 15 30 40 40 50 12.5 18.5 24 23 — — XTAE040D00_ _ 3 10 15 20 40 50 50 60 15.5 22 30 30 — — XTAE050D00_ _ 5 15 20 25 50 60 65 72 20 30 39 35 — — XTAE065D00_ _ Frame F 7-1/2 15 25 30 60 75 80 110 25 37 48 63 — — XTAE080F00_ _ 7-1/2 15 25 40 75 100 95 110 30 45 57 75 — — XTAE095F00_ _ Frame G 10 25 40 50 100 125 115 160 37 55 70 105 — — XTAE115G00_ _ 15 30 40 60 125 125 150 160 48 75 91 125 — — XTAE150G00_ _ � Underscore (_) indicates magnet coil suffix required. See Table 34-67. � Underscore (_) indicates overload relay suffix required. See Table 34-69. � For electrical life contactor application data see Table 34-68. Reversing Starters, C396 Electronic Overload Table 34-66. Full Voltage Reversing Starters with Screw Terminals and C396 Electronic Overload Maximum 3-Phase Motor Rating I (A) Maximum kW Ratings AC-3 Catalog Price e �� Number U.S. $ 1-Phase hp Ratings 3-Phase hp Ratings AC-3 3-Phase Motors 50 – 60 Hz Standard 115V 230V 200V 230V 460V 575V 220/ 380/ 415V 660/ AC Coil DC Coil 230V 400V 690V Frame B 1/4 1 1-1/2 2 3 5 7 2.2 3 4 3.5 XTAR007B21_ _ 1/2 1-1/2 3 3 5 7-1/2 9 2.5 4 5.5 4.5 XTAR009B21_ _ 1 2 3 3 10 10 12 3.5 5.5 7 6.5 XTAR012B21_ _ Frame C 2 3 5 5 10 15 18 5 7.5 8 11 XTAR018C21_ _ 2 5 7-1/2 7-1/2 15 20 25 7.5 11 14.5 14 XTAR025C21_ _ 3 5 10 10 20 25 32 10 15 18 17 XTAR032C21_ _ Frame D 3 7-1/2 10 15 30 40 40 12.5 18.5 24 23 XTAR040D11_ _ 3 10 15 20 40 50 50 15.5 22 30 30 XTAR050D11_ _ 5 15 20 25 50 60 65 20 30 39 35 XTAR065D11_ _ � Underscore (_) indicates magnet coil suffix required. See Table 34-67. Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-43 � Underscore (_) indicates overload relay suffix required. See Table 34-69. Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-113 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-43 XT IEC Power Control March 2009 Contactors and Starters Table 34-67. Magnet Coil Suffix Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code Frame A – B Frame C – F Frame G 110V 50 Hz, 120V 60 Hz A 110V 50 Hz, 120V 60 Hz A 100 – 120V 50/60 Hz A 220V 50 Hz, 240V 60 Hz B 220V 50 Hz, 240V 60 Hz B 190 – 240V 50/60 Hz B 230V 50 Hz F 230V 50 Hz F 24V 50/60 Hz T 24V 50/60 Hz T 24V 50/60 Hz T 24 – 27V DC TD 24V DC TD 24 – 27V DC TD 480 – 500V 50/60 Hz C 34 415V 50 Hz, 480V 60 Hz C 415V 50 Hz, 480V 60 Hz C 380 – 440V 50/60 Hz L 550V 50 Hz, 600V 60 Hz D 550V 50 Hz, 600V 60 Hz D 42 – 48V 50/60 Hz W 208V 60 Hz E 208V 60 Hz E 110 – 130V DC AD 190V 50 Hz, 220V 60 Hz G 190V 50 Hz, 220V 60 Hz G 200 – 240V DC BD 240V 50 Hz, 277V 60 Hz H 240V 50 Hz, 277V 60 Hz H 48 – 60V DC WD 380V 50 Hz, 440V 60 Hz L 380V 50 Hz, 440V 60 Hz L Frame L – N 400V 50 Hz N 400V 50 Hz N 110 – 250V 40 – 60 Hz/DC A 380V 60 Hz P 380V 60 Hz P 250 – 500V 40 – 60 Hz C 12V 50/60 Hz R 12V 50/60 Hz R 48 – 110V 40 – 60 Hz/DC Y � 24V 50 Hz U 24V 50 Hz U 24 – 48V DC TD 42V 50 Hz, 48V 60 Hz W 42V 50 Hz, 48V 60 Hz W Frame L – N, S-Series 48V 50 Hz Y 48V 50 Hz Y 110 – 120V 50/60 Hz A 120V DC AD 110 – 130V DC AD 220 – 240V 50/60 Hz B 220V DC BD 200 – 240V DC BD Frame P – R � 12V DC RD 12 – 14V DC RD 220 – 250V 50 – 60 Hz/DC B 48V DC WD 48 – 60V DC WD � Frame C – D only. � Frame L – M only. � Table 34-68. Contactor Application Data Catalog Electrical Life (Operations) for Prefix 10hp, 480V (14.2A) Applications XTCE012B 1 million XTCE015B 1.2 million XTCE018C 2 million � See Page 34-88 for Electrical Life Curves. Table 34-69. C396 Overload Relay Suffix FLA Suffix For Use with XT IEC Catalog Range Contactor Frame Size / Number (Amps) Width Std. Class Standard Class 5/10/20/30 5/10/20/30 45 mm Overload Frame Size 0.1 – 0.5 3EP05 B / 45 mm C396A2AP05SELXB 0.4 – 2.0 3E002 B / 45 mm C396A2A002SELXB 1 – 5 3E005 B / 45 mm C396A2A005SELXB 1.6 – 8 3E008 B / 45 mm C396A2A008SELXB 6.4 – 32 3E032 B / 45 mm C396A2A032SELXB 0.1 – 0.5 3EP05 C / 45 mm C396A2AP05SELXC 0.4 – 2.0 3E002 C / 45 mm C396A2A002SELXC 1 – 5 3E005 C / 45 mm C396A2A005SELXC 1.6 – 8 3E008 C / 45 mm C396A2A008SELXC 6.4 – 32 3E032 C / 45 mm C396A2A032SELXC 6.4 – 32 3E032 D / 55 mm C396A2A032SELXD 9 – 45 3E045 D / 55 mm C396A2A045SELXD 65 mm Overload Frame Size 15 – 75 3E075 D / 55 mm C396B2A075SELXD 22 – 110 3E110 F – G / 90 mm C396B2A110SELXF 110 mm Overload Frame Size � 30 – 150 3E150 G / 90 mm C396C2A150SELAX � Catalog Number listed is for Stand-Alone Overload Relay. For direct connection of 110 mm C396 to Frame G XT Contactors use 110 mm XT Bus Bar Kit, C396CBARXT. Accessories . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-113 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-44 XT IEC Power Control March 2009 Contactors and Starters Star-Delta (Wye-Delta) Starters Table 34-70. Star-Delta (Wye-Delta) Starters Maximum 3-Phase Current I (A) Maximum kW Ratings AC-3 Maximum Components e Motor Rating Changeover Time (sec) 3-Phase hp Ratings AC-3 3-Phase Motors 50 – 60 Hz Description Catalog � Number 200V 230V 460V 575V 220/ 380/ 415V 500V 660/ 1000V 230V 400V 690V 34 Frame B 3 3 2-1/2 10 12 3 5.5 7 5.5 5.5 — <20 K1M Main Contactor XTCE007B10_ K5M Delta Contactor XTCE007B01_ K3M Star Contactor XTCE007B01_ Mechanical Interlock XTCEXMLB K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…BC1 (3) Auxiliary Contacts XTCEXFAC20 Star-Delta Link Kit XTCEXSDLB 3 5 7-1/2 10 16 4 7.5 8 7.5 7.5 — <20 K1M Main Contactor XTCE009B10_ K5M Delta Contactor XTCE009B01_ K3M Star Contactor XTCE009B01_ Mechanical Interlock XTCEXMLB K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…BC1 (3) Auxiliary Contacts XTCEXFAC20 Star-Delta Link Kit XTCEXSDLB 5 5 10 15 22 5.5 11 14.5 11 11 — <20 K1M Main Contactor XTCE012B10_ K5M Delta Contactor XTCE012B01_ K3M Star Contactor XTCE012B01_ Mechanical Interlock XTCEXMLB K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…BC1 (3) Auxiliary Contacts XTCEXFAC20 Star-Delta Link Kit XTCEXSDLB Frame C 7-1/2 7-1/2 15 20 30 7.5 15 19 18.5 18.5 — <20 K1M Main Contactor XTCE018C10_ K5M Delta Contactor XTCE018C01_ K3M Star Contactor XTCE018C01_ Mechanical Interlock XTCEXMLC K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…CC1 (3) Auxiliary Contacts XTCEXFAC20 Star-Delta Link Kit XTCEXSDLC 10 15 30 40 45 11 22 30 30 22 — <20 K1M Main Contactor XTCE025C10_ K5M Delta Contactor XTCE025C01_ K3M Star Contactor XTCE025C01_ Mechanical Interlock XTCEXMLC K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…CC1 (3) Auxiliary Contacts XTCEXFAC20 Star-Delta Link Kit XTCEXSDLC 15 20 40 50 55 15 30 39 37 30 — <20 K1M Main Contactor XTCE032C10_ K5M Delta Contactor XTCE032C01_ K3M Star Contactor XTCE032C01_ Mechanical Interlock XTCEXMLC K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…CC1 (3) Auxiliary Contacts XTCEXFAC20 Star-Delta Link Kit XTCEXSDLC Frame D 20 25 50 60 70 18.5 37 37 45 37 — <20 K1M Main Contactor XTCE040D00_ K5M Delta Contactor XTCE040D00_ K3M Star Contactor XTCE040D00_ Mechanical Interlock XTCEXMLD K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…DC1 (2) Auxiliary Contacts (K1M, K3M) XTCEXFBG11 (1) Auxiliary Contact (K5M) XTCEXFBG31 Star-Delta Link Kit XTCEXSDLD 25 30 60 75 90 22 45 45 55 45 — <20 K1M Main Contactor XTCE050D00_ K5M Delta Contactor XTCE050D00_ K3M Star Contactor XTCE040D00_ Mechanical Interlock XTCEXMLD K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…DC1 (2) Auxiliary Contacts (K1M, K3M) XTCEXFBG11 (1) Auxiliary Contact (K5M) XTCEXFBG31 Star-Delta Link Kit XTCEXSDLD � Underscore (_) indicates magnet coil suffix required. See Table 34-72. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-45 XT IEC Power Control March 2009 Contactors and Starters Table 34-70. Star-Delta (Wye-Delta) Starters (Continued) Maximum 3-Phase Current I (A) Maximum kW Ratings AC-3 Maximum Components e Motor Rating Changeover Time (sec) 3-Phase hp Ratings AC-3 3-Phase Motors 50 – 60 Hz Description Catalog � Number 200V 230V 460V 575V 220/ 380/ 415V 500V 660/ 1000V 230V 400V 690V Frame D (Continued) 40 50 100 125 115 30 55 55 75 55 — <20 K1M Main Contactor XTCE065D00_ 34 K5M Delta Contactor XTCE065D00_ K3M Star Contactor XTCE040D00_ Mechanical Interlock XTCEXMLD K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…DC1 (2) Auxiliary Contacts (K1M, K3M) XTCEXFBG11 (1) Auxiliary Contact (K5M) XTCEXFBG31 Star-Delta Link Kit XTCEXSDLD Frame F 40 60 125 150 140 37 75 75 90 90 — <20 K1M Main Contactor XTCE080F00_ K5M Delta Contactor XTCE080F00_ � K3M Star Contactor XTCE050D00_ � Mechanical Interlock XTCEXMLG K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…FC1 (2) Auxiliary Contacts (K1M, K3M) XTCEXFBG11 (1) Auxiliary Contact (K5M) XTCEXFBG31 Star-Delta Link Kit XTCEXSDLF 40 60 125 150 165 45 90 110 110 132 — <20 K1M Main Contactor XTCE095F00_ K5M Delta Contactor XTCE095F00_ � K3M Star Contactor XTCE065D00_ � Mechanical Interlock XTCEXMLG K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…FC1 (2) Auxiliary Contacts (K1M, K3M) XTCEXFBG11 (1) Auxiliary Contact (K5M) XTCEXFBG31 Star-Delta Link Kit XTCEXSDLF Frame G 50 60 125 150 200 55 110 132 132 160 — <20 K1M Main Contactor XTCE115G00_ K5M Delta Contactor XTCE115G00_ K3M Star Contactor XTCE080F00_ Mechanical Interlock XTCEXMLG K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…GC1 (2) Auxiliary Contacts XTCEXFBG11 (1) Auxiliary Contact (K5M) XTCEXFBG31 Star-Delta Link Kit XTCEXSDLG 75 100 200 250 260 75 132 148 160 160 — <20 K1M Main Contactor XTCE150G00_ K5M Delta Contactor XTCE150G00_ K3M Star Contactor XTCE080F00_ Mechanical Interlock XTCEXMLG K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…GC1 (2) Auxiliary Contacts XTCEXFBG11 (1) Auxiliary Contact (K5M) XTCEXFBG31 Star-Delta Link Kit XTCEXSDLG Frame L 100 125 250 300 315 90 160 180 200 250 132 <30 K1M Main Contactor XTCE185L22_ K5M Delta Contactor XTCE185L22_ � K3M Star Contactor XTCE115G00_ � Mechanical Interlock XTCEXMLM K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…LC1 K3M Auxiliary Contact XTCEXFBG22 Star-Delta Link Kit XTCEXSDLL225 125 150 300 400 385 110 200 240 250 315 160 <20 K1M Main Contactor XTCE225L22_ K5M Delta Contactor XTCE225L22_ � K3M Star Contactor XTCE150G00_ � Mechanical Interlock XTCEXMLM K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…LC1 K3M Auxiliary Contact XTCEXFBG22 Star-Delta Link Kit XTCEXSDLL225 125 150 300 400 430 132 250 300 315 400 200 <30 K1M Main Contactor XTCE250L22_ K5M Delta Contactor XTCE250L22_ K3M Star Contactor XTCE185L22_ Mechanical Interlock XTCEXMLM K1T Timing Relay XTTR6A60S51B Overload Relay XTOB…LC1 Star-Delta Link Kit XTCEXSDLL250 � Underscore (_) indicates magnet coil suffix required. See Table 34-72. � If mechanical interlock of Star Contactor is required, it must be the same frame size of the Delta Contactor or use the same mechanical interlock, see Table 34-86, Page 34-57 for mechanical interlocks. (Example: XTCE...L22_ and XTCE...M22_ both use Mechanical Interlock XTCEXMLM.) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-46 XT IEC Power Control March 2009 Contactors and Starters Table 34-70. Star-Delta (Wye-Delta) Starters (Continued) Maximum 3-Phase Current I (A) Maximum kW Ratings AC-3 Maximum Components e Motor Rating Changeover Time (sec) 3-Phase hp Ratings AC-3 3-Phase Motors 50 – 60 Hz Description Catalog � Number 200V 230V 460V 575V 220/ 380/ 415V 500V 660/ 1000V 230V 400V 690V Frame M 150 200 400 500 515 160 300 348 355 450 200 <30 K1M Main Contactor XTCE300M22_ 34 K5M Delta Contactor XTCE300M22_ K3M Star Contactor XTCE185L22_ Mechanical Interlock XTCEXMLM K1T Timing Relay XTTR6A60S51B Overload Relay XTOT…C3S Star-Delta Link Kit XTCEXSDLM400 200 250 500 600 685 200 355 390 450 560 220 <20 K1M Main Contactor XTCE400M22_ K5M Delta Contactor XTCE400M22_ K3M Star Contactor XTCE250L22_ Mechanical Interlock XTCEXMLM K1T Timing Relay XTTR6A60S51B Overload Relay XTOT…C3S Star-Delta Link Kit XTCEXSDLM400 290 350 700 860 860 250 450 500 560 600 220 <30 K1M Main Contactor XTCE500M22_ K5M Delta Contactor XTCE500M22_ K3M Star Contactor XTCE300M22_ Mechanical Interlock XTCEXMLM K1T Timing Relay XTTR6A60S51B Overload Relay XTOT…C3S Frame N — — — — 1000 300 560 610 710 900 355 <30 K1M Main Contactor XTCE580N22_ K5M Delta Contactor XTCE580N22_ � K3M Star Contactor XTCE400M22_ � Mechanical Interlock XTCEXMLN K1T Timing Relay XTTR6A60S51B Overload Relay XTOT…C3S — — — — 1120 350 630 680 750 950 355 <30 K1M Main Contactor XTCE650N22_ K5M Delta Contactor XTCE650N22_ � K3M Star Contactor XTCE400M22_ � Mechanical Interlock XTCEXMLN K1T Timing Relay XTTR6A60S51B Overload Relay XTOT…C3S — — — — 1290 400 710 760 900 1200 1400 <30 K1M Main Contactor XTCE750N22_ K5M Delta Contactor XTCE750N22_ K3M Star Contactor XTCE580N22_ Mechanical Interlock XTCEXMLN K1T Timing Relay XTTR6A60S51B Overload Relay XTOT…C3S — — — — 1400 450 800 850 950 1300 1400 <30 K1M Main Contactor XTCE820N22_ K5M Delta Contactor XTCE820N22_ K3M Star Contactor XTCE580N22_ Mechanical Interlock XTCEXMLN K1T Timing Relay XTTR6A60S51B Overload Relay XTOT…C3S — — — — 1700 560 1000 1050 1200 1700 1700 <20 K1M Main Contactor XTCEC10N22_ K5M Delta Contactor XTCEC10N22_ K3M Star Contactor XTCE650N22_ Mechanical Interlock XTCEXMLN K1T Timing Relay XTTR6A60S51B Overload Relay XTOT…C3S � Underscore (_) indicates magnet coil suffix required. See Table 34-72. � If mechanical interlock of Star contactor is required, it must be the same frame size of the Delta contactor or use the same mechanical interlock, see Table 34-86, Page 34-57 for mechanical interlocks. (Example: XTCE...L22_ and XTCE...M22_ both use Mechanical Interlock XTCEXMLM.) Notes: Table 34-71. Spare Auxiliary Contacts Main Circuit: Depending on the coordination AC-3 K1M K3M K5M type required (i.e. Type 1 or Type 2) it must 12 – 55 63 63 63 be established whether the fuse protection and the input wiring for the main and delta 64 64 64 contactors are to be common or separate. 90 – 260 — — 21 33 Control Circuit: If the combinations are used in the scope of the IEC/EN 60 204-1, VDE 22 34 0113 part 1, point 9.1.1 regarding the supply of control circuits is to be observed. 315 – 1700 21 31 31 43 31 43 22 32 32 44 32 44 Coil Voltage Chart . . . . . . . . . . . . . . . . Page 34-47 Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-49 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-91 Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-47 XT IEC Power Control March 2009 Contactors and Starters Table 34-72. Magnet Coil Suffix Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code Frame A – B Frame C – F Frame G 110V 50 Hz, 120V 60 Hz A 110V 50 Hz, 120V 60 Hz A 100 – 120V 50/60 Hz A 220V 50 Hz, 240V 60 Hz B 220V 50 Hz, 240V 60 Hz B 190 – 240V 50/60 Hz B 230V 50 Hz F 230V 50 Hz F 24V 50/60 Hz T 24V 50/60 Hz T 24V 50/60 Hz T 24 – 27V DC TD 34 24V DC TD 24 – 27V DC TD 480 – 500V 50/60 Hz C 415V 50 Hz, 480V 60 Hz C 415V 50 Hz, 480V 60 Hz C 380 – 440V 50/60 Hz L 550V 50 Hz, 600V 60 Hz D 550V 50 Hz, 600V 60 Hz D 42 – 48V 50/60 Hz W 208V 60 Hz E 208V 60 Hz E 110 – 130V DC AD 190V 50 Hz, 220V 60 Hz G 190V 50 Hz, 220V 60 Hz G 200 – 240V DC BD 240V 50 Hz, 277V 60 Hz H 240V 50 Hz, 277V 60 Hz H 48 – 60V DC WD 380V 50 Hz, 440V 60 Hz L 380V 50 Hz, 440V 60 Hz L Frame L – N 400V 50 Hz N 400V 50 Hz N 110 – 250V 40 – 60 Hz/DC A 380V 60 Hz P 380V 60 Hz P 250 – 500V 40 – 60 Hz C 12V 50/60 Hz R 12V 50/60 Hz R 48 – 110V 40 – 60 Hz/DC Y � 24V 50 Hz U 24V 50 Hz U 24 – 48V DC TD 42V 50 Hz, 48V 60 Hz W 42V 50 Hz, 48V 60 Hz W Frame L – M, S-Series 48V 50 Hz Y 48V 50 Hz Y 110 – 120V 50/60 Hz A 120V DC AD 110 – 130V DC AD 220 – 240V 50/60 Hz B 220V DC BD 200 – 240V DC BD Frame P – R � 12V DC RD 12 – 14V DC RD 220 – 250V 50 – 60 Hz/DC B 48V DC WD 48 – 60V DC WD � Frame C – D only. � Frame L – M only. L1L2 L3 21 21 0 0 F1 22 22 S11 S11 1 x l B n K1M K1M 13 13 13 13 I I 14 14 14 14 1533 15 135 K1M K5M K3M 2 4 6 2 4 6 2 4 6 54 54 54 44 14 14 17 17 17 17 K1M K1 K1 K1M K1 K1 53 53 53 18 43 13 13 18 28 28 0.58 x ln A C K3M K5M K3M K5M 0.58 x l n 22 22 22 22 K5M K3M K5M K3M 21 21 21 21 A1 A1 A1 A1 A1 A1 A1 A1 U1 V2 K1M K1T K3M K5M K1M K1T K3M K5M M1 V1 W2 A2 A2 A2 A2 A2 A2 A2 A2 W1 3~ U2 (–)N (–)N M1 N Y N Y 12 – 385A AC-3 12 – 55A AC-3 70 – 1700A AC-3 Overload Relay Settings (A) Setting Starting A: I x 0.58 ≤ 15 sec N Motor Protection in the Star (Wye) and Delta Configurations B: I x 1 15 – 40 sec N Only partial motor protection in Star position C: I x 0.58 > 40 sec N Motor not protected in Star (Wye) position Timing Relay set to approximately 10 sec Figure 34-35. Wiring Diagrams Overload Relays . . . . . . . . . . . . . . . . . Page 34-104 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-48 XT IEC Power Control March 2009 Contactors and Starters Table 34-75. Engineering Notes for XTCC and XTCE Contactors for Power Factor Correction Catalog Switching Duty in kVar Number 230V 400V 525V 690V 420V 440V Individual Compensation, Open Version XTCE007B 1.5 3 3.5 5 34 XTCE009B 2 4 4.5 6 XTCE012B 2.5 4.5 5.5 7 XTCE015B 2.5 4.5 5.5 7 Table 34-73. XTCC Contactors for Three-Phase Capacitors XTCE018C 6.5 12 14.5 19 Three-Phase Capacitors, 50 – 60 Hz Contact Catalog Price XTCE025C 7 13.5 16 21 � �� Open kVar Ratings Sequence Number U.S. $ XTCE032C 7.5 14.5 17 22.5 230V 400V 525V 690V XTCE040D 11 20.5 24.5 32 XTCE050D 11.5 22 26 34.5 11 20 25 33.3 XTCC020C11_ XTCE065D 12.5 23.5 28 37 15 25 33.3 40 XTCC025C11_ XTCE080F 16 30.5 36.5 48 1 3 5 13 21 A1 XTCE095F 18 34 41 54 XTCE115G 24 46 54.5 72 A2 2 4 6 14 22 XTCE150G 28 53 63.5 83.5 XTCE185L 87 150 190 150 XTCE300M 115 200 265 200 20 33.3 40 55 XTCC033D10_ XTCE580N 175 300 400 300 25 50 65 85 XTCC050D10_ Group Compensation, with Reactor, Open Version 1 3 5 13 A1 XTCE007B 4 7 7.5 12 2 4 6 14 A2 XTCE009B 5 8 10 14 XTCE012B 5.5 10 12 16 XTCE015B 5.5 10 12 16 XTCE018C 7.5 16 20 28 � With series resistors, without quick-discharge resistor. XTCE025C 9 18 23 30 � Underscore (_) indicates magnet coil suffix required, see Table 34-74. XTCE032C 10 20 24 32 � Contact Eaton for availability. XTCE040D 13 25 30 40 Notes: XTCE050D 16 30 36 48 XTCE065D 19 36 43 57 ■ Weld-resistant for capacitors with inrush ■ For switching of power factor connection current peaks up to 180 x I . with reactors please observe engineering XTCE080F 30 58 68 90 N notes, Table 34-75. Use of the contactors XTCE095F 34 66 79 104 XTCE without series resistor for centralized XTCE115G 44 80 100 125 L1 L2 L3 power factor correction — when using XTCE150G 50 97 115 152 contactors for group compensation, a XTCE185L 80 150 200 260 minimum inductance of approximately 6 μH XTCE225L 100 175 230 300 per capacitor must be available to limit the XTCE250L 110 190 260 340 high inrush current peaks. This corresponds XTCE300M 130 225 290 390 1 3 5 A1 to an air-cored coil with 5 windings and a coil XTCE400M 160 280 370 480 diameter of approximately 140 mm diameter. XTCE500M 220 390 500 680 A2 2 4 6 The conductor cross-section must be Group Compensation, without Reactor, selected according to the rated current Open Version per phase. XTCC020C 11 20 25 33.3 Table 34-74. Magnet Coil Suffix XTCC025C 15 25 33.3 40 R1 1 R1 1 XTCC033D 20 33.3 40 55 Coil Voltage Suffix C1 XTCC050D 25 50 65 85 Code XTCR185L 66 115 145 115 R11 110V 50 Hz, 120V 60 Hz A XTCE300M 85 150 195 150 220V 50 Hz, 240V 60 Hz B XTCE580N 145 250 333 250 230V 50 Hz, 240V 60 Hz F Figure 34-36. Wiring Diagram 400V 50 Hz, 440V 60 Hz N ■ In the case of group compensation multi- 24V 50/60 Hz T stage capacitor banks are connected to the mains, as required. In the process, transient currents of up to 180 x I can flow between e the capacitors. The capacitors are pre- charged via the early-make auxiliary contacts and the fitted wire resistors, thereby reducing the inrush current. The main contacts then close after a time lag and carry the uninterrupted current. The contactors for capacitors are weld-resistant with inrush current peaks up to 180 x 1 I due to their e special contacts. For switching reactive- power compensation equipment with chokes, observe design notes. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-49 XT IEC Power Control March 2009 Contactors and Starters Accessories Notes: contact module. 6 auxiliary contacts are Auxiliary Contacts The 7 – 32A XTCE Contactors have posi- possible with a combination of side Front mounted snap-on auxiliary con- tively driven contacts between the inte- mounted and front mount auxiliary tacts for XT contactors are available grated auxiliary contact and the auxiliary contacts. contact module as well as within the auxil- with screw or spring cage terminals in Frame B – C contactors with 1NC built-in iary contact modules. a variety of contact configurations. auxiliary are mirror contacts (XTCE...B01_ – 34 The 40 – 65A XTCE Contactors have posi- XTCE...C01_). tively driven contacts within the auxiliary Table 34-76. XTCE and XTCS Auxiliary Contact Overview Frame A B C D F G L – R Catalog XTMC6A... – XTCE007B... – XTCE018C... – XTCE040D00_ – XTCE080F00_ – XTCE115G00_ – XTCE185L22_ – � Numbers XTMC9A... XTCE015B... XTCE032C... XTCE072D00_ XTCE095F00_ XTCE170G00_ XTCEC20R22_ Contactor Width 45 mm 45 mm 45 mm 55 mm 90 mm 90 mm Various Built-In Auxiliary 1NO or 1NC 1NO or 1NC 1NO or 1NC — — — 2NO-2NC Contact Sequence A1 1 35 13 1 1 A1 1 3 5 13 21 31 43 A1 3 5 21 A1 3 5 A2 2 4 6 14 A2 2 46 14 22 32 44 A2 2 46 22 A2 2 46 Front (Top) Mount 2-Pole & 4-Pole Standard 2-Pole & 4-Pole Ver- 2-Pole (Screw Only): N/A Auxiliary (Screw or Spring Cage): sions (Screw or Spring Cage): 4-Pole (Screw or Spring Cage): Tall Version (Screw Only): Side Mount N/A 1-Pole (Screw 2-Pole (Screw 2-Pole (Screw or Spring Cage): Auxiliary Only): Only): � Frame L – R auxiliary contacts also apply to XTCS185L… – XTCS500M… contactors. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-50 XT IEC Power Control March 2009 Contactors and Starters Table 34-77. Auxiliary Contacts Conventional Poles Contact Circuit Symbol Pkg. Screw Terminals Spring Cage Terminals Price � Thermal Current, Configuration Qty. U.S. $ Catalog Catalog Open at 60°C Number Number I = I , th e AC-1 in Amps Frame B – C — Front (Top) Mount 16 2 2NO 5 XTCEXFAC20 XTCEXFACC20 5363 34 5464 16 2 1NO-1NC 5 XTCEXFAC11 XTCEXFACC11 53 61 54 62 16 2 2NC 5 XTCEXFAC02 XTCEXFACC02 51 61 52 62 � � 16 2 1NO -1NC 5 XTCEXFALC11 XTCEXFALCC11 E L 57 65 58 66 � � 16 2 1NO-1NC 5 XTCEXFDC11 XTCEXFDCC11 21 33 22 34 21 31 � � 16 2 2NC 5 XTCEXFCC02 XTCEXFCCC02 21 31 22 32 16 4 4NO 5 XTCEXFAC40 XTCEXFACC40 536373 83 5464 7484 16 4 3NO-1NC 5 XTCEXFAC31 XTCEXFACC31 53 61 73 83 54 62 74 84 16 4 2NO-2NC 5 XTCEXFAC22 XTCEXFACC22 53 61 71 83 5462 72 84 16 4 1NO-3NC 5 XTCEXFAC13 XTCEXFACC13 536171 81 54 82 6272 16 4 4NC 5 XTCEXFAC04 XTCEXFACC04 5161 71 81 526272 82 � � 16 4 1NO -1NC 5 XTCEXFCLC22 XTCEXFCLCC22 E L 65 57 71 83 5866 72 84 � � 16 4 2NO-2NC 5 XTCEXFCC22 XTCEXFCCC22 21 31 43 53 32 44 54 22 Frame B — Side Mount 16 1 1NO 1 XTCEXSAB10 — 53 54 16 1 1NC 1 XTCEXSAB01 — 51 52 � Orders must be placed in multiples of package quantity listed. � 1 early-make contact (1NO ), 1 late-break contact (1NC ). E L � To avoid duplicate terminal numbers in contact sequence, these auxiliary contacts should only be used with contactors having a built-in 1NO contact (XTCE...B10_, XTCE...C10_). Technical Data . . . . . . . . . . . . . . . . . . Page 34-79 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-51 XT IEC Power Control March 2009 Contactors and Starters Table 34-77. Auxiliary Contacts (Continued) Conventional Poles Contact Circuit Symbol Pkg. Screw Terminals Spring Cage Terminals Price � Thermal Current, Configuration Qty. U.S. $ Catalog Catalog Open at 60°C Number Number Ith = Ie, AC-1 in Amps � Frame B – C — Front (Top) Mount — Tall Version 16 2 2NO 5 XTCEXFATC20 — 5363 34 5464 16 2 1NO-1NC 5 XTCEXFATC11 — 53 61 54 62 16 2 2NC 5 XTCEXFATC02 — 51 61 52 62 16 4 2NO-2NC 5 XTCEXFATC22 — 53 61 71 83 5462 72 84 Frame C — Side Mount � 10 2 1NO-1NC 1 XTCEXSCC11 — 53 61 54 62 Frame D – G 16 2 2NO 5 XTCEXFBG20 — 13 23 14 24 16 2 1NO-1NC 5 XTCEXFAG11 — 53 61 54 62 16 2 1NO-1NC 5 XTCEXFBG11 — 13 21 14 22 16 2 2NC 5 XTCEXFBG02 — 11 21 1222 16 4 4NO-0NC 5 XTCEXFBG40 XTCEXFBGC40 13 23 33 43 14 24 34 44 16 4 3NO-1NC 5 XTCEXFBG31 XTCEXFBGC31 13 21 33 43 14 22 3444 16 4 2NO-2NC 5 XTCEXFBG22 XTCEXFBGC22 13 21 31 43 14 22 32 44 16 4 2NO-2NC 5 XTCEXFAG22 XTCEXFAGC22 53 61 71 83 5462 72 84 16 4 1NO-3NC 5 XTCEXFBG13 XTCEXFBGC13 13 21 41 31 14 223242 16 4 0NO-4NC 5 XTCEXFBG04 XTCEXFBGC04 11 213141 12223242 � � 16 4 1NO -1NC 5 XTCEXFBLG22 XTCEXFBLGC22 E L 13 21 35 47 14 22 36 48 � � Orders must be placed in multiples of pack- Can be mounted to the left side of contactor ■ Auxiliary break contact can be used as mirror age quantity listed. only. Cannot be used in combination with contact to IEC/EN 60947-4-1 Annex F (not NC � front (top) mount auxiliary contacts or (late break) contact). 1 early-make contact (1NO ), 1 late-break E mechanical interlocks. contact (1NC ). ■ No auxiliary contacts can be fitted between L � two contactors. Front (Top) Mount Tall Version is for use with Notes: Frame B Electrical Wire Bridges and Link ■ Interlocked opposing contacts, to IEC/EN Kits (see Page 34-57) and Toolless Plug Com- 60947-5-1 Annex L (positively driven), within bination Connection Kits: XTCEXRLB, the auxiliary contact modules (not NO (early XTCEXSDLB, XTPAXTPCB, XTPAXTPCRB, make) and NC (late break) contacts) and for Technical Data . . . . . . . . . . . . . . . . . . Page 34-79 XTPAX. the built-in auxiliary contacts of the Discount Symbol . . . . . . . . . . . . . . . . 1CD7 XTCE007B... – XTCE032C.... CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-52 XT IEC Power Control March 2009 Contactors and Starters Table 34-78. Side Mount Auxiliary Contacts for Frame D – R, 40 – 2000A Conventional Free Air Poles Contact Circuit Symbol Pkg. Screw Terminals Spring Cage Terminals Price Thermal Current, Configuration Qty. U.S. $ Catalog Catalog I = I , AC-1 in Amps th e Number Number Frame D – R 10 2 1NO-1NC 1 XTCEXSBN11 XTCEXSBNC11 13 21 14 22 34 � 10 2 1NO -1NC 1 XTCEXSBLN11 — E L 17 25 18 26 � � 10 2 1NO-1NC 1 XTCEXSCN11 XTCEXSCNC11 53 61 54 62 Frame D – R (Screw Mount) 10 2 1NO-1NC 1 XTCEXSBR11 — 13 21 14 22 10 2 1NO -1NC 1 XTCEXSBLR11 — E L 17 25 18 26 10 2 1NO-1NC 1 XTCEXSCR11 — 53 61 54 62 � 1 early-make contact (1NO ), 1 late-break contact (1NC ). E L � To maintain proper terminal marking, XTCEXSCN_ should not be used with Frame D contactors and only used with Frame F – G contactors in combination with XTCEXSBN_. Technical Data . . . . . . . . . . . . . . . . . . Page 34-79 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E 71 83 72 84 35 47 36 48 31 43 32 44 71 83 72 84 35 47 36 48 31 43 32 44 IEC Contactors & Starters 34-53 XT IEC Power Control March 2009 Contactors and Starters Table 34-79. Auxiliary Contacts Possible Combinations Frame Catalog Contactor Built-In Front (Top) Mount Side Mount Total Auxiliary Size Number Auxiliary Contacts Available 2-Pole 4-Pole 1-Pole 2-Pole A XTMC6A… – 1NO or 1NC 1 — — — 3 XTMC9A… —1 — — 5 ——— 34 B XTCE007B… – 1NO or 1NC 1 — — — 3 XTCE015B… —1 — — 5 ——1 — 2 —— C XTCE018C… – 1NO or 1NC 1 — — — 3 XTCE032C… —1 — — 5 ——— 1 3 —— D XTCE040D00_ – —1 — — 2 6 XTCE065D00_ —1 — 1 6 —— F – G XTCE080F00_ – —1 — — 2 6 XTCE150G00_ —1 — 2 8 ——— 4 8 —— L – R XTCE185L22_ – 2NO-2NC — — 2 8 XTCEC20R22_ —— — Notes: ■ Forced operation contact to IEC/EN 60947-5-1 Appendix L (positively driven), inside the auxiliary contact unit (not early close and late opening). ■ Auxiliary normally closed contact can be used as mirror contact to IEC/EN 60947-4-1 Appendix F (not late opening). ■ No auxiliary contacts can be fitted between two contactors. Technical Data . . . . . . . . . . . . . . . . . . Page 34-79 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-54 XT IEC Power Control March 2009 Contactors and Starters XTMC6A... – XTMC9A... XTMCXF...A... 2-Pole or 4-Pole 34 Frame A XTCE007B... – XTCE015B XTCEXF...C... + or XTCE007B... – XTCE015B... 2-Pole or 4-Pole Not for use with mechanical interlock. Frame B XTCE007B... – XTCE032C... XTCEXF...C... or + XTCE018C... – XTCE032C... 2-Pole or 4-Pole Frame C XTCE040D... – XTCE065D... XTCE040D... – XTCE065D... XTCEXF...G... XTCEXF...G... + or + 2-Pole 4-Pole Frame D XTCE080F... – XTCE150G... XTCEXF...G... + or + + XTCE080F... – XTCE150G... 2-Pole or 4-Pole Frame F – G + + XTCE185L... – XTCEC20R... Frame L – R Figure 34-37. Auxiliary Contact Combinations For more information visit: www.eaton.com CA08102001E XTCEXSBN11 XTCEXSBN11 XTCEXSAB... XTCEXSCN11 XTCEXSBN11 (Built-In) XTCEXSBN11 XTCEXSBN11 XTCEXSCN11 XTCEXSBN11 XTCEXSBN11 XTCEXSCC11 XTCEXSBN11 (Built-In) XTCEXSCN11 XTCEXSBN11 XTCEXSBN11 XTCEXSCN11 + + + + + + + IEC Contactors & Starters 34-55 XT IEC Power Control March 2009 Contactors and Starters �� Suppressors Varistor Suppressor with Integrated LED The switching of contactor coils can generate voltage tran- sients that may cause arching on switch contacts and/or damage electronics on the control line. Either a RC or Varis- A1 tor Suppressor is recommended in these types of applica- A2 tions. All XT DC contactor coils have built-in suppression. Contact Sequence Varistor Suppressors clamp the voltage transient above the 34 Table 34-82. Varistor Suppressor maximum coil voltage and are recommended when the level of the transient is known to not exceed the coil voltage. RC Voltage For Use Pkg. Catalog Price � Suppressors slow and reduce the level of the voltage tran- AC with… Qty. Number U.S. $ sient but do not clamp them at a specific level. The slowing 24 – 48 XTCE007B – XTCE015B 10 XTCEXVSLBW of the transient can reduce electrical interference. These are 130 – 240 10 XTCEXVSLBB recommended in applications where operating rates are high. 24 – 48 XTCE018C – XTCE032C 10 XTCEXVSLCW 130 – 240 10 XTCEXVSLCB �� RC Suppressor 24 – 48 XTCE040D – XTCE095F 10 XTCEXVSLFW 130 – 240 10 XTCEXVSLFB � Note drop-out delay. A1 � For AC operated contactors, 50/60 Hz. DC operated contactors have an Contact Sequence integrated suppressor. � A2 Orders must be placed in multiples of package quantity listed. � Free-Wheel Diode Suppressor Table 34-80. RC Suppressor Voltage For Use Pkg. Catalog Price � A1 with… Qty. Number U.S. $ 24 – 48 XTCE007B – XTCE015B, 10 XTCEXRSBW Contact Sequence 48 – 130 XTCF020B 10 XTCEXRSBA 110 – 240 10 XTCEXRSBB 240 – 500 10 XTCEXRSBC A2 24 – 48 XTCE018C – XTCE032C 10 XTCEXRSCW 110 – 130 10 XTCEXRSCA Table 34-83. Free-Wheel Diode Suppressor 130 – 240 10 XTCEXRSCB Voltage For Use Pkg. Catalog Price 240 – 500 10 XTCEXRSCC � DC with… Qty. Number U.S. $ 24 – 48 XTCE040D – XTCE095F 10 XTCEXRSFW 110 – 130 10 XTCEXRSFA 12 – 250 XTCE007B – XTCE015B, 10 XTCEXDSB 130 – 240 10 XTCEXRSFB XTCF020B 240 – 500 10 XTCEXRSFC � In addition to the built-in suppressor circuit for DC actuated contactors. � Note drop-out delay. Prevents negative breaking voltage when contactors are used in � For AC operated contactors, 50 – 60 Hz. DC operated contactors and combination with a safety PLC. XTCE115G_ to XTCE170G_ have a built-in suppressor circuit. � Orders must be placed in multiples of package quantity listed. � Orders must be placed in multiples of package quantity listed. Voltage Indicator �� Varistor Suppressor A1 A1 Contact Sequence Contact Sequence A2 A2 Table 34-84. Voltage Indicator Table 34-81. Varistor Suppressor Voltage For Use Pkg. Catalog Price Voltage For Use Pkg. Catalog Price � DC with… Qty. Number U.S. $ � with… Qty. Number U.S. $ 12 – 48 XTCE007B – XTCE015B, 10 XTCEXVIBW 24 – 48 XTCE007B – XTCE015B, 10 XTCEXVSBW 48 – 130 XTCF020B 10 XTCEXVIBA 48 – 130 XTCF020B 10 XTCEXVSBA 130 – 240 10 XTCEXVSBB 110 – 250 10 XTCEXVIBB 240 – 500 10 XTCEXVSBC 24 – 48 XTCE018C – XTCE032C 10 XTCEXVICW 24 – 48 XTCE018C – XTCE032C 10 XTCEXVSCW 48 – 130 10 XTCEXVICA 48 – 130 10 XTCEXVSCA 130 – 250 10 XTCEXVICB 130 – 240 10 XTCEXVSCB 42 – 48 DC operated: 10 XTCEXVIGW 240 – 500 10 XTCEXVSCC 48 – 130 XTCE040D – XTCE095F 10 XTCEXVIGA 24 – 48 XTCE040D – XTCE095F 10 XTCEXVSFW 130 – 250 AC/DC operated: 10 XTCEXVIGB 48 – 130 10 XTCEXVSFA XTCE115G – XTCE150G 130 – 240 10 XTCEXVSFB � 240 – 500 10 XTCEXVSFC Orders must be placed in multiples of package quantity listed. � Note drop-out delay. � For AC operated contactors, 50/60 Hz. DC operated contactors have a built-in suppressor. � Orders must be placed in multiples of package quantity listed. Technical Data . . . . . . . . . . . . . . . . . Page 34-79 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-56 XT IEC Power Control March 2009 Contactors and Starters � Electronic Timer Modules Table 34-85. Electronic Timer Modules for Frame B – C Contactors (7 – 32A) Voltage Contact Timing For Use Pkg. Catalog Price Sequence Range with… Qty. Number U.S. $ On-Delayed 24V AC/DC 0.05 s – 1 s XTCE...B... 1 XTCEXTEEC11T 57 65 A1 0.5 – 10 s XTCE...C... 100 – 130V AC XTCEXTEEC11A 34 5 s – 100 s A2 200 – 240V AC 58 66 XTCEXTEEC11B Off-Delayed 24V AC/DC 0.05 s – 1 s XTCE...B... 1 XTCEXTED1C11T 5765 A1 XTCE...C... 100 – 130V AC XTCEXTED1C11A A2 200 – 230V AC 5866 XTCEXTED1C11B 24V AC/DC 0.5 – 10 s XTCE...B... 1 XTCEXTED10C11T 5765 A1 XTCE...C... 100 – 130V AC XTCEXTED10C11A A2 200 – 240V AC 5866 XTCEXTED10C11B 24V AC/DC 5 s – 100 s XTCE...B... 1 XTCEXTED100C11T 5765 A1 XTCE...C... 100 – 130V AC XTCEXTED100C11A A2 200 – 240V AC 5866 XTCEXTED100C11B Star-Delta 24V AC/DC 1 s – 30 s XTCE...B... 1 XTCEXTEYC20T 57 67 A1 XTCE...C... 100 – 130V AC XTCEXTEYC20A A2 200 – 240V AC 58 68 XTCEXTEYC20B Sealable Shroud — Transparent sealable shroud used to XTCEXTEE, 1 XTCEXTESHRD protect electronic timer modules XTCEXTED, from unwanted access. XTCEXTEY � Front (Top) mounted timer modules for use with XTCE...B and XTCE…C contactors. Cannot be combined with top mount auxiliary contacts, XTCEXF...C__. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-57 XT IEC Power Control March 2009 Contactors and Starters � Table 34-87. Reversing Link Kits Mechanical Interlock For Use Pkg. Catalog Price with… Qty. Number U.S. $ � XTCE007B – XTCE015B 1 XTCEXRLB Table 34-86. Mechanical Interlock 34 XTCE018C – XTCE032C 1 XTCEXRLC For Use Pkg. Catalog Price � XTCE040D – XTCE065D 1 XTCEXRLD with… Qty. Number U.S. $ XTCE080F – XTCE150G 1 XTCEXRLG XTCE007B – XTCE015B, 5 XTCEXMLB XTCE185L – XTCE250L 1 XTCEXRLL XTCF020B XTCE300M – XTCE400M 1 XTCEXRLM400 � Also includes Interlocking Bridge (XTCEXLBB). The following control cables are integrated for electrical interlock: K1M: A1 – K2M: 21; XTCE018C – XTCE032C 1 XTCEXMLC K1M: 21 – K2M: A1; K1M: A2 – K2M: A2. XTCF032C – XTCF045C XTCE040D – XTCE072D 1 XTCEXMLD Star-Delta (Wye-Delta) Link Kits XTCF063D – XTCF080D � XTCE080F – XTCE170G 1 XTCEXMLG XTCF125G – XTCF200G XTCE185L – XTCE570M 1 XTCEXMLM Main current wiring for star-delta (wye-delta) combinations. Includes Paralleling Bridge, Reversing Bridge, and Star-Delta Bridge. Does not include Mechanical Interlock, see Table 34-86. Table 34-88. Star-Delta (Wye-Delta) Link Kits For Use Pkg. Catalog Price with… Qty. Number U.S. $ � XTCE580N – XTCEC10N 1 XTCEXMLN � XTCE007B – XTCE015B 1 XTCEXSDLB � XTCE500M – XTCE570M 1 XTCEXMLNM XTCE018C – XTCE032C 1 XTCEXSDLC with XTCE040D – XTCE065D 1 XTCEXSDLD XTCE580N – XTCEC10N XTCE080F – XTCE095F 1 XTCEXSDLF XTCE115G – XTCE150G 1 XTCEXSDLG XTCE185L – XTCE225L 1 XTCEXSDLL225 XTCE250L 1 XTCEXSDLL250 XTCE300M – XTCE400M 1 XTCEXSDLM400 � For two contactors with AC or DC operated magnet system which are � horizontally or vertically mounted. For B – G frames, mechanical lifespan Also includes Interlocking Bridge (XTCEXLBB). The following control 6 is 2.5 x 10 operations and the distance between contactors is 0 mm. For cables are integrated for electrical interlock: K1M: A1 – K2M: 21; 6 L – N frames, mechanical lifespan is 5 x 10 operations and no auxiliary K1M: 21 – K2M: A1; K1M: A2 – K2M: A2. contact can be mounted between the mechanical interlock and the contactor — the distance between contactors is 15 mm. Paralleling Bridge � Orders must be placed in multiples of package quantity listed. � XTCEXMLG, XTCEXMLN and XTCEXMLNM consist of an interlock element and mounting plate. Component part of Reversing Link Kit (XTCEXRL_). Parallels Reversing Link Kits the phases on the line-side of two contactors. Main current wiring for reversing Table 34-89. Paralleling Bridge combinations. Includes Paralleling For Use Pkg. Catalog Price Bridge and Reversing Bridge. Does � with… Qty. Number U.S. $ not include Mechanical Interlock, see XTCE007B – XTCE015B 20 XTCEXPBB Table 34-86. XTCE018C – XTCE032C 20 XTCEXPBC XTCE040D – XTCE065D 10 XTCEXPBD XTCE080F – XTCE150G 10 XTCEXPBG � Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-58 XT IEC Power Control March 2009 Contactors and Starters � Reversing Bridge Connector Component part of Reversing Link Kit (XTCEXRL_). Reverses the phases on the load-side of two contactors. Table 34-93. Connector Table 34-90. Reversing Bridge For Use Pkg. Catalog Price 34 � with… Qty. Number U.S. $ For Use Pkg. Catalog Price � with… Qty. Number U.S. $ XTCE007B – XTCE032C 50 XTCEXCNC XTCE007B – XTCE015B 20 XTCEXRBB XTCE018C – XTCE032C 20 XTCEXRBC XTCE040D – XTCE065D 10 XTCEXRBD XTCE080F – XTCE150G 10 XTCEXRBG � Orders must be placed in multiples of package quantity listed. XTCE040D – XTCE150G 10 XTCEXCNG Electrical Interlocking Bridge Connects NC auxiliary contact with A2 terminal of other contactor in reversing application. Included in XTCEXRLB reversing link kit. Table 34-91. Electrical Interlocking Bridge For Use Pkg. Catalog Price � For mechanically arranging contactors in combinations. Distance � with… Qty. Number U.S. $ between contactors is 0 mm. � Orders must be placed in multiples of package quantity listed. XTCE007B – XTCE015B 20 XTCEXLBB � Orders must be placed in multiples of package quantity listed. Add-On Fourth Pole Star-Delta (Wye-Delta) Bridge Add-On Fourth Pole for use with Frame D contactors. Only for AC-1 load. Up to two auxiliary contacts can be fitted. Component part of Star-Delta Link Kit (XTCEXSDL_). Com- mons the 3-phases on the line side of shorting contactor. Table 34-94. Fourth Pole Table 34-92. Star-Delta (Wye-Delta) Bridge For Use AC-1 (A) Pkg. Catalog Price with… Open/ Qty. Number U.S. $ For Use Pkg. Catalog Price � Enclosed with… Qty. Number U.S. $ XTCE040D00_ 35/30A 1 XTCEX4P35D � XTCE007B – XTCE015B 20 XTCEXSDBB XTCE050D00_ 75/60A 1 XTCEX4P75D XTCE018C – XTCE032C 20 XTCEXSDBC XTCE065D00_ XTCE072D00_ XTCE040D – XTCE072D 10 XTCEXSDBD XTCE080F – XTCE170G 1 XTCEXSDBG XTCE185L – XTCE400M 1 XTCEXSDB400 XTCE500M 1 XTCEXSDB500 � Orders must be placed in multiples of package quantity listed. � Frame B is tool-less connection type. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-59 XT IEC Power Control March 2009 Contactors and Starters ��� Parallel Link Incoming Terminal Terminal for use with three-phase commoning link XTCEXCLK_B. Table 34-97. Incoming Terminal For Use Pkg. Catalog Price � with… Qty. Number U.S. $ For using one contactor per phase. Each package comes with (2) links for line: load. XTCE007B – 5 XTCEXITB 34 XTCE015B Table 34-95. Parallel Link For Use Pkg. Catalog Price � with… Qty. Number U.S. $ � Orders must be placed in multiples of package quantity listed. XTCE007B – 5 XTCEXPLKB XTCE015B Terminal Lug Assembly For connection of: round conductor, flexible and stranded, flat strip conductor. With control circuit terminal. See Table XTCE018C – 5 XTCEXPLKC 34-119, Page 34-79 for terminal capacities. XTCE032C Table 34-98. Terminal Lug Assembly XTCE040D – 1 XTCEXPLKD XTCE072D For Use Pkg. Catalog Price XTCE080F – 1 XTCEXPLKG with… Qty. Number U.S. $ XTCE170G XTCE250L – 1 XTCEXTLA400 XTCE185L 1 XTCEXPLKL185 XTCE400M � Fourth Pole can be broken off: 4-Pole: I = 60A; 3-Pole: I = 50A. th th � AC-1 current carrying capacity of the contactor increases by a factor of Terminal Lug Kit — Set of (3) Lugs 2.5. For XTCEXPLKL185, one shroud is included for protection against accidental contact. � Protected against accidental contact in accordance with IEC 536. � Orders must be placed in multiples of package quantity listed. 3-Phase Commoning Link Main current wiring that parallels and commons the line side of multiple contactors. For use with Frame B contactors only. Protected against accidental contact, short-circuit proof. Max voltage (U ) = 690V, Max Current (I ) = 63A. Table 34-99. Set of (3) Lugs e e For Use Description Pkg. Catalog Price Table 34-96. 3-Phase Commoning Link with… Qty. Number U.S. $ Notes Pkg. Catalog Price XTCE500M, Set of 3 Lugs #4-500MCM 1 XTCEXTL500 � Qty. Number U.S. $ XTCE570M 2-Phase Cu/Al 500A Suitable for 3 5 XTCEXCLK3B XTCE650N Set of 3 Lugs #2-500MCM 1 XTCEXTL650 contactors, 2-Phase Cu/Al 650A length = 135 mm XTCE820N Set of 3 Lugs #2-500MCM 1 XTCEXTL820 Suitable for 4 5 XTCEXCLK4B 4-Phase Cu/Al 820A contactors, length = 180 mm Terminal Flat Bar Suitable for 5 5 XTCEXCLK5B contactors, For connection of a flat strip conductor. Comes with control length = 225 mm circuit terminal (consisting of 3 flat strip conductor terminals). � Orders must be placed in multiples of package quantity listed. Table 34-100. Terminal Flat Bar For Use Pkg. Catalog Price with… Qty. Number U.S. $ XTCE500M – 1 XTCEXTFB650 XTCE570M XTCE750N – 1 XTCEXTFB820 XTCE820N Note: Not UL Listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-60 XT IEC Power Control March 2009 Contactors and Starters Control Wire Terminal Extension Terminal Shrouds Protection against direct contact with connection lugs when touched vertically from the front. Table 34-102. Terminal Shrouds For Use Pkg. Catalog Price with… Qty. Number U.S. $ Fits to Frame F – G contactors and allows connection of con- 34 XTCE185L – 1 XTCEXTS400 trol wire to power terminals. XTCE400M XTCE500M – 1 XTCEXTS500 Table 34-101. Control Wire Terminal Extension XTCE570M For Use Pkg. Catalog Price XTCE580N – 1 XTCEXTS650 � with… Qty. Number U.S. $ XTCE650N XTCE750N – 1 XTCEXTS820 XTCE080F – XTCE150G 10 XTCEXTCWG XTCEC10N � Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-61 XT IEC Power Control March 2009 Contactors and Starters Renewal Parts Table 34-103. Replacement Coils 34 Voltage Coil Catalog Price Voltage Coil Catalog Price Suffix Number U.S. $ Suffix Number U.S. $ � Frame C Frame G 110/50 120/60 A XTCERENCOILCA 100 – 120V 50/60 A XTCERENCOILGA 110 – 130V DC AD XTCERENCOILCAD 110 – 130V DC AD XTCERENCOILGAD 220/50 240/60 B XTCERENCOILCB 190 – 240V 50/60 B XTCERENCOILGB 200 – 240V DC BD XTCERENCOILCBD 200 – 240V DC BD XTCERENCOILGBD 480 – 500V 50/60 C XTCERENCOILGC 415/50 480/60 C XTCERENCOILCC 550/50 600/60 D XTCERENCOILCD 380 – 440V 50/60 L XTCERENCOILGL 208/60 E XTCERENCOILCE 4/50 24/60 T XTCERENCOILGT 230/50 F XTCERENCOILCF 24 – 27V DC TD XTCERENCOILGTD 42 – 48V 50/60 W XTCERENCOILGW 190/50 220/60 G XTCERENCOILCG 48 – 60V DC WD XTCERENCOILGWD 240/50 277/60 H XTCERENCOILCH � 380/50 440/60 L XTCERENCOILCL Frame L 400/50 N XTCERENCOILCN 110 – 250V AC/DC A XTCERENCOILLA 380/60 P XTCERENCOILCP 250 – 500V 40 – 60 C XTCERENCOILLC 12/50 12/60 R XTCERENCOILCR 24 – 48V DC TD XTCERENCOILLTD 12 – 14V DC RD XTCERENCOILCRD 48 – 110V AC/DC Y XTCERENCOILLY 24/50 24/60 T XTCERENCOILCT Frame L, S-Series 24 – 27V DC TD XTCERENCOILCTD 110 –120V 50/60 Hz A XTCSRENCOILLA 24/50 U XTCERENCOILCU 220 – 240V 50/60 Hz B XTCSRENCOILLB 42/50 48/60 W XTCERENCOILCW � Frame M 48 – 60V DC WD XTCERENCOILCWD 110 – 250V AC/DC A XTCERENCOILMA 48/50 Y XTCERENCOILCY 250 – 500V 40 – 60 C XTCERENCOILMC Frame D 24 – 48V DC TD XTCERENCOILMTD 110/50 120/60 A XTCERENCOILDA 48 – 110V AC/DC Y XTCERENCOILMY 110 – 130V DC AD XTCERENCOILDAD Frame M, S-Series 220/50 240/60 B XTCERENCOILDB 110 – 120V 50/60 Hz A XTCSRENCOILMA 200 – 240V DC BD XTCERENCOILDBD 220 – 240V 50/60 Hz B XTCSRENCOILMB 415/50 480/60 C XTCERENCOILDC � Frame N 550/50 600/60 D XTCERENCOILDD 208/60 E XTCERENCOILDE 110 – 250V AC/DC A XTCERENCOILNA 230/50 F XTCERENCOILDF 250 – 500V 40 – 60 C XTCERENCOILNC 48 – 110V AC/DC Y XTCERENCOILNY 190/50 220/60 G XTCERENCOILDG 240/50 277/60 H XTCERENCOILDH � Electronic modules including coils. 380/50 440/60 L XTCERENCOILDL � Frame G replacement coils can only be used with contactors having 400/50 N XTCERENCOILDN date codes of 2706 or later. 380/60 P XTCERENCOILDP 12/50 12/60 R XTCERENCOILDR Table 34-104. Replacement Contact Kits 12 – 14V DC RD XTCERENCOILDRD 24/50 24/60 T XTCERENCOILDT For Use with… Catalog Number Price U.S. $ 24 – 27V DC TD XTCERENCOILDTD XTCE040D – XTCE065D XTCERENCONTACTD 24/50 U XTCERENCOILDU XTCE185L – XTCE250L XTCERENCONTACTL 42/50 48/60 W XTCERENCOILDW XTCE300M – XTCE570M XTCERENCONTACTM 48 – 60V DC WD XTCERENCOILDWD 48/50 Y XTCERENCOILDY XTCE085F – XTCE095F XTCERENCONTACTF � Frame F XTCE115G – XTCE150G XTCERENCONTACTG 110/50 120/60 A XTCERENCOILFA 110 – 130V DC AD XTCERENCOILFAD Table 34-105. Replacement Vacuum Tube Assembly 220/50 240/60 B XTCERENCOILFB 200 – 240V DC BD XTCERENCOILFBD For Use with… Catalog Number Price U.S. $ 415/50 480/60 C XTCERENCOILFC XTCE580N XTCERENVACT580 550/50 600/60 D XTCERENCOILFD XTCE650N XTCERENVACT650 208/60 E XTCERENCOILFE XTCE750N XTCERENVACT750 230/50 F XTCERENCOILFF XTCE820N XTCERENVACT820 190/50 220/60 G XTCERENCOILFG 240/50 277/60 H XTCERENCOILFH 380/50 440/60 L XTCERENCOILFL Table 34-106. Replacement Arc Chambers 400/50 N XTCERENCOILFN For Use with… Catalog Number Price U.S. $ 380/60 P XTCERENCOILFP 12/50 12/60 R XTCERENCOILFR XTCE185L XTCERENARC185 24/50 24/60 T XTCERENCOILFT XTCE225L XTCERENARC225 24 – 27V DC TD XTCERENCOILFTD XTCE250L XTCERENARC250 24/50 U XTCERENCOILFU XTCE300M XTCERENARC300 42/50 48/60 W XTCERENCOILFW XTCE400M XTCERENARC400 48 – 60V DC WD XTCERENCOILFWD XTCE500M – XTCE570M XTCERENARC500 48/50 Y XTCERENCOILFY � Frame F replacement coils can only be used with contactors having the following date codes: DC Coils, 2706 or later; AC Coils, 4706 or later. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-62 XT IEC Power Control March 2009 Contactors and Starters Technical Data and Specifications Contents Description Page XTCE 3-Pole Contactors . . . . 34-62 XTCE Coil Data . . . . . . . . . . . . 34-72 34 XTCF 4-Pole Contactors . . . . 34-62 XTCF Coil Data . . . . . . . . . . . . 34-72 Auxiliary Contacts . . . . . . . . . 34-79 AC Ratings . . . . . . . . . . . . . . . 34-80 DC Ratings . . . . . . . . . . . . . . . 34-85 Frame B XTCE Contactor Heat Loss . . . . . . . . . . . . . . . . 34-87 Life Curves . . . . . . . . . . . . . . . 34-88 Overload Relays . . . . . . . . . . . 34-108 Type 2 Coordination . . . . . . . 34-210 XT Contactors Frame B Table 34-107. XT Contactors Technical Data and Specifications — Frame B Description XTCE007B XTCE009B XTCE012B XTCE015B General Standards IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS Weights in kg [Lb] AC operated 0.23 [0.51] 0.23 [0.51] 0.23 [0.51] 0.23 [0.51] DC operated 0.28 [0.62] 0.28 [0.62] 0.28 [0.62] 0.28 [0.62] Mechanical Life 10,000,000 10,000,000 10,000,000 10,000,000 Mechanical Operating Frequency (ops/hr) AC operated 9000 9000 9000 5000 DC operated 9000 9000 9000 5000 Electrical Life See Curves, Page 34-88 Electrical Operating Frequency (ops/hr) — see Curve, Page 34-88 AC-1; 400V Ie 800 800 800 800 AC-3; 400V Ie 1000 1000 1000 1000 AC-4; 400V Ie 300 300 300 300 Climatic Proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 Insulation Voltage (Ui) V AC 690 690 690 690 Impulse Withstand Voltage (U ) V AC 8000 8000 8000 8000 imp Operational Voltage (Ue) V AC 690 690 690 690 Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and contacts (V AC) 400 400 400 400 Between contacts (V AC) 400 400 400 400 � Making Capacity Up to 690V (Amps) 112 112 144 155 Breaking Capacity (Amps) 220/230V 70 90 120 124 380/400V 70 90 120 124 500V 50 70 100 100 660/690V 40 50 70 70 Short-Circuit Protection Rating Maximum Fuse � Type 2 Coordination 400V; gG/gL 500V 20 20 20 20 690V; gG/gL 690V 16 16 20 20 � Type 1 Coordination 400V; gG/gL 500V 35 35 35 63 690V; gG/gL 690V 20 20 20 50 Degree of Protection IP20 Protection against Direct Contact when Actuated Finger- and back-of-hand proof from Front (IEC 536) � IEC 60947 Standard. � Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated. For more information visit: www.eaton.com CA08102001E 90° IEC Contactors & Starters 34-63 XT IEC Power Control March 2009 Contactors and Starters Table 34-107. XT Contactors Technical Data and Specifications — Frame B (Continued) Description XTCE007B XTCE009B XTCE012B XTCE015B General (Continued) Terminal Capacity Main Cable — Screw Terminals 2 Solid (mm ) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 34 Solid or Stranded (AWG) 18 – 14 18 – 14 18 – 14 18 – 14 Terminal Capacity Control Circuit Cable — Screw Terminals 2 Solid (mm ) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) Solid or Stranded (AWG) 18 – 14 18 – 14 18 – 14 18 – 14 Main Cable and Control Circuit Cable Connection Screw/Bolt M3.5 M3.5 M3.5 M3.5 Tightening torque Nm 1.2 1.2 1.2 1.2 Lb-in 10.6 10.6 10.6 10.6 Tools Main and Control circuit cable — Screw Terminals Size 2 Size 2 Size 2 Size 2 Pozidriv screwdriver 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 Standard screwdriver 1 x 6 1 x 6 1 x 6 1 x 6 Terminal Capacity Main Circuit Cable — Spring Cage Terminals 2 Solid (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 Flexible (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) Solid or Stranded (AWG) 18 – 14 18 – 14 18 – 14 18 – 14 Terminal Capacity Control Circuit Cable — Spring Cage Terminals 2 Solid (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 Flexible (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) Solid or Stranded (AWG) 18 – 14 18 – 14 18 – 14 18 – 14 Tools Main and Control Circuit Cable — Spring Cage Terminals Stripping Length (mm) 10 10 10 10 Screwdriver blade width (mm) 3.5 3.5 3.5 3.5 Mounting Position, AC and DC Operated 30° Ambient Temperature Open -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] Enclosed -25 to 40°C -25 to 40°C -25 to 40°C -25 to 40°C [-13 to 104°F] [-13 to 104°F] [-13 to 104°F] [-13 to 104°F] Ambient Storage Temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 mS Main contact — NO Contact 10g 10g 10g 10g Auxiliary contact — NO Contact 7g 7g 7g 7g Auxiliary contact — NC Contact 5g 5g 5g 5g Overvoltage Category/Pollution degree III/3 III/3 III/3 III/3 CA08102001E For more information visit: www.eaton.com 90° 90° 180° IEC Contactors & Starters 34-64 XT IEC Power Control March 2009 Contactors and Starters Frame C – D Table 34-108. XT Contactors Technical Data and Specifications — Frame C – D Description XTCE018C XTCE025C XTCE032C XTCE040D XTCE050D XTCE065D, XTCE072D General Standards IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS Weights in kg [Lb] 34 AC operated 0.42 [0.93] 0.42 [0.93] 0.42 [0.93] 0.9 [2.0] 0.9 [2.0] 0.9 [2.0] DC operated 0.48 [1.06] 0.48 [1.06] 0.48 [1.06] 1.1 [2.4] 1.1 [2.4] 1.1 [2.4] Mechanical Life 10,000,000 10,000,000 10,000,000 10,000,000 10,000,000 10,000,000 Mechanical Operating Frequency (ops/hr) AC operated 5000 5000 5000 5000 5000 5000 DC operated 5000 5000 5000 5000 5000 5000 Electrical Mechanical Operating Frequency (ops/hr) — see Curve, Page 34-88 AC-1; 400V Ie 800 800 800 800 800 800 AC-3; 400V Ie 800 800 800 800 800 800 AC-4; 400V Ie 300 300 300 300 300 300 Climatic Proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 Insulation Voltage (Ui) V AC 690 690 690 690 690 690 Impulse Withstand Voltage (U ) V AC 8000 8000 8000 8000 8000 8000 imp Operating Voltage (Ue) V AC 690 690 690 690 690 690 Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and contacts (V AC) 440 440 440 440 440 440 Between contacts (V AC) 238 440 440 440 440 440 Making Capacity (Amps) 238 350 384 560 700 910 Breaking Capacity (Amps) 220/230V 170 250 320 400 500 650 380/400V 170 250 320 400 500 650 500V 170 250 320 400 500 650 660/690V 120 150 180 250 320 370 Short-Circuit Protection Rating Maximum Fuse (Amps) � Type 2 Coordination 400V; gG/gL 500V 25 35 63 63 80 125 690V; gG/gL 690V 25 35 35 50 63 80 � Type 1 Coordination 400V; gG/gL 500V 63 100 125 125 160 250 690V; gG/gL 690V 50 50 63 80 80 100 Degree of Protection IP00 Protection against Direct Contact when Finger- and back-of-hand proof Actuated from Front (IEC 536) Terminal Capacity Main Cable — Screw Terminals 2 Solid (mm ) 1 x (0.75 – 16) 1 x (0.75 – 16) 1 x (0.75 – 16) 1 x (0.75 – 16) 1 x (0.75 – 16) 1 x (0.75 – 16) 2 x (0.75 – 10) 2 x (0.75 – 10) 2 x (0.75 – 10) 2 x (0.75 – 10) 2 x (0.75 – 10) 2 x (0.75 – 10) 2 Flexible with ferrule (mm ) 1 x (0.75 – 16) 1 x (0.75 – 16) 1 x (0.75 – 16) 1 x (2.5 – 35) 1 x (2.5 – 35) 1 x (2.5 – 35) 2 x (0.75 – 10) 2 x (0.75 – 10) 2 x (0.75 – 10) 2 x (2.5 – 25) 2 x (2.5 – 25) 2 x (2.5 – 25) 2 Stranded (mm ) 1 x 16 1 x 16 1 x 16 1 x (16 – 50) 1 x (16 – 50) 1 x (16 – 50) 2 x (16 – 35) 2 x (16 – 35) 2 x (16 – 35) Solid or Stranded (AWG) 18 – 6 18 – 6 18 – 6 12 – 2 12 – 2 12 – 2 Flat Conductor ———2 x (6 x 9 x 0.8) 2 x (6 x 9 x 0.8) 2 x (6 x 9 x 0.8) (Number of Segments x Width x Thickness) (mm) Main Cable Connection Screw/Bolt M5 M5 M5 M6 M6 M6 Tightening torque Nm 3 3 3 3.3 3.3 3.3 Lb-in 26.6 26.6 26.6 29.2 29.2 29.2 Terminal Capacity Control Circuit Cable — Screw Terminals 2 Solid (mm ) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 2 x (0.75 – 4) 2 x (0.75 – 4) 2 x (0.75 – 4) 2 x (0.75 – 4) 2 x (0.75 – 4) 2 x (0.75 – 4) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) Solid or Stranded (AWG) 18 – 14 18 – 14 18 – 14 18 – 14 18 – 14 18 – 14 Control Circuit Cable Connection Screw/Bolt M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 Tightening torque Nm 1.2 1.2 1.2 1.2 1.2 1.2 Lb-in 10.6 10.6 10.6 10.6 10.6 10.6 � IEC 60947 Standard. For more information visit: www.eaton.com CA08102001E 90° 90° IEC Contactors & Starters 34-65 XT IEC Power Control March 2009 Contactors and Starters Table 34-108. XT Contactors Technical Data and Specifications — Frame C – D (Continued) Description XTCE018C XTCE025C XTCE032C XTCE040D XTCE050D XTCE065D, XTCE072D General (Continued) Tools Main and Control Circuit Cable — Screw Terminals Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Pozidriv screwdriver 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 Standard screwdriver 1 x 6 1 x 6 1 x 6 1 x 6 1 x 6 1 x 6 34 Terminal Capacity Control Circuit Cable — Spring Cage Terminals 2 Solid (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 Flexible (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) Solid or Stranded (AWG) 18 – 14 18 – 14 18 – 14 18 – 14 18 – 14 18 – 14 Tools Main and Control Circuit Cable — Spring Cage Terminals Stripping Length (mm) 10 10 10 10 10 10 Screwdriver blade width (mm) 3.5 3.5 3.5 3.5 3.5 3.5 Mounting Position, AC and DC operated 30° 30° 30° Ambient Temperature Open -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] Enclosed -25 to 40°C -25 to 40°C -25 to 40°C -25 to 40°C -25 to 40°C -25 to 40°C [-13 to 104°F] [-13 to 104°F] [-13 to 104°F] [-13 to 104°F] [-13 to 104°F] [-13 to 104°F] Ambient Storage Temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Main contact — NO Contact 10 10 10 10 10 10 Auxiliary contact — NO Contact 7 7 7 7 7 7 Auxiliary contact — NC Contact 5 5 5 5 5 5 Overvoltage Category / Pollution Degree III/3 III/3 III/3 III/3 III/3 III/3 CA08102001E For more information visit: www.eaton.com 90° 90° 90° 180° 180° IEC Contactors & Starters 34-66 XT IEC Power Control March 2009 Contactors and Starters Frame F – G Table 34-109. XT Contactors Technical Data and Specifications — Frame F – G Description XTCE080F XTCE095F XTCE115G XTCE150G XTCE170G General Standards IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS Weights in kg [Lb] AC operated 2 [4.41] 2 [4.41] 2 [4.41] 2 [4.41] 2 [4.41] 34 DC operated 2.1 [4.63] 2.1 [4.63] 2.1 [4.63] 2.1 [4.63] 2.1 [4.63] Mechanical Life 10,000,000 10,000,000 10,000,000 10,000,000 10,000,000 Mechanical Operating Frequency (ops/hr) AC operated 3600 3600 3600 3600 3600 DC operated 3600 3600 3600 3600 3600 Electrical Mechanical Operating Frequency (ops/hr) — see Curve, Page 34-88 AC-1; 400V Ie 800 800 800 800 800 AC-3; 400V Ie 800 800 800 800 800 AC-4; 400V Ie 300 300 300 300 300 Climatic Proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 Insulation Voltage (Ui) V AC 1000 1000 1000 1000 1000 Impulse Withstand Voltage (U ) V AC 8000 8000 8000 8000 8000 imp Operational Voltage (Ue) V AC 1000 1000 1000 1000 1000 Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and contacts (V AC) 690 690 690 690 690 Between contacts (V AC) 690 690 690 690 690 Making Capacity (Amps) 1120 1330 1610 2100 2100 Breaking Capacity (Amps) 220/230V 800 950 1150 1500 1500 380/400V 800 950 1150 1500 1500 500V 800 950 1150 1500 1500 660/690V 650 800 1100 1200 1320 1000V — — — — — Short-Circuit Protection Rating Maximum Fuse � Type 2 Coordination 400V; gG/gL 500V 160 160 250 250 400 690V; gG/gL 690V 160 160 250 250 250 � Type 1 Coordination 400V; gG/gL 500V 250 250 250 250 400 690V; gG/gL 690V 200 200 250 250 250 Degree of Protection IP00 Protection Against Direct Contact when Finger- and back-of-hand proof Actuated from Front (IEC 536) Terminal Capacity Main Cable — Screw Terminals 2 Solid (mm) ————— 2 Flexible with ferrule (mm ) 1 x (10 – 95) 1 x (10 – 95) 1 x (10 – 95) 1 x (10 – 95) 1 x (10 – 95) 2 x (10 – 70) 2 x (10 – 70) 2 x (10 – 70) 2 x (10 – 70) 2 x (10 – 70) 2 Stranded (mm ) 1 x (16 – 120) 1 x (16 – 120) 1 x (16 – 120) 1 x (16 – 120) 1 x (16 – 120) 2 x (16 – 95) 2 x (16 – 95) 2 x (16 – 95) 2 x (16 – 95) 2 x (16 – 95) Flat Conductor 2 x (6 x 16 x 0.8) 2 x (6 x 16 x 0.8) 2 x (6 x 16 x 0.8) 2 x (6 x 16 x 0.8) 2 x (6 x 16 x 0.8) (Number of Segments x Width x Thickness) (mm) Solid or Stranded (AWG) 8 – 250 MCM 8 – 250 MCM 8 – 250 MCM 8 – 250 MCM 8 – 250 MCM Main Cable Connection Screw/Bolt M10 M10 M10 M10 M10 Tightening torque Nm 14 14 14 14 14 Lb-in 123.9 123.9 123.9 123.9 123.9 Terminal Capacity Control Circuit Cable — Screw Terminals 2 Solid (mm ) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 1 x (0.75 – 4) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) Solid or Stranded (AWG) 18 – 14 18 – 14 18 – 14 18 – 14 18 – 14 Control Circuit Cable Connection Screw/Bolt M3.5 M3.5 M3.5 M3.5 M3.5 Tightening torque Nm 1.2 1.2 1.2 1.2 1.2 Lb-in 10.6 10.6 10.6 10.6 10.6 � IEC 60947 Standard. For more information visit: www.eaton.com CA08102001E 90° 90° IEC Contactors & Starters 34-67 XT IEC Power Control March 2009 Contactors and Starters Table 34-109. XT Contactors Technical Data and Specifications — Frame F – G (Continued) Description XTCE080F XTCE095F XTCE115G XTCE150G XTCE170G General (Continued) Tools Main Circuit Cable — Screw Terminals Hexagon Socket-Head Spanner (mm) 5 5 5 5 5 Control Circuit Cable — Screw Terminals Size 2 Size 2 Size 2 Size 2 Size 2 Pozidriv screwdriver 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 0.8 x 5.5 Standard screwdriver 1 x 6 1 x 6 1 x 6 1 x 6 1 x 6 34 Terminal Capacity Control Circuit Cable — Spring Cage Terminals 2 Solid (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 Flexible (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) Solid or Stranded (AWG) 18 – 14 18 – 14 18 – 14 18 – 14 18 – 14 Tools Control Circuit Cable — Spring Cage Terminals Stripping Length (mm) 10 10 10 10 10 Screwdriver blade width (mm) 3.5 3.5 3.5 3.5 3.5 Mounting Position, AC and DC operated 30° 30° 30° 30° Ambient Temperature Open -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] Enclosed -25 to 40°C -25 to 40°C -25 to 40°C -25 to 40°C -25 to 40°C [-13 to 104°F) [-13 to 104°F) [-13 to 104°F) [-13 to 104°F) [-13 to 104°F) Ambient Storage Temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 mS Main contact — NO Contact 10g 10g 10g 10g 10g Auxiliary contact — NO Contact 7g 7g 7g 7g 7g Auxiliary contact — NC Contact 5g 5g 5g 5g 5g Overvoltage Category/Pollution Degree III/3 III/3 III/3 III/3 III/3 CA08102001E For more information visit: www.eaton.com 90° 90° 180° 180° IEC Contactors & Starters 34-68 XT IEC Power Control March 2009 Contactors and Starters Frame L – M Table 34-110. XT Contactors Technical Data and Specifications — Frame L – M Description XTCE185L, XTCE225L, XTCE250L, XTCE300M, XTCE400M, XTCE500M, XTCE570M, XTCS185L XTCS225L XTCS250L XTCS300M XTCS400M XTCS500M XTCS570M General Standards IEC/EN 60947, VDE 0660, UL, CSA Weights in kg [Lb] 6.5 [14.3] 6.5 [14.3] 6.5 [14.3] 8 [18] 8 [18] 8 [18] 8 [18] 34 Mechanical Life 10,000,000 10,000,000 10,000,000 7,000,000 7,000,000 7,000,000 7,000,000 Mechanical Operating Frequency (ops/hr) AC operated 3000 3000 3000 2000 2000 2000 2000 DC operated 3000 3000 3000 2000 2000 2000 2000 Mechanical Operating Frequency (ops/hr) See Figure 34-45 on Page 34-90. Climatic Proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 Insulation Voltage (Ui) V AC 1000 1000 1000 1000 1000 1000 1000 Impulse Withstand Voltage (U ) V AC 8000 8000 8000 8000 8000 8000 8000 imp Operating Voltage (Ue) V AC 1000 1000 1000 1000 1000 1000 1000 Safe Isolation to VDE 0106 Part 101 and Part 101/A1 500 500 500 500 500 500 500 Between coil and contacts (V AC) 500 500 500 500 500 500 500 Between contacts (V AC) Making Capacity (Amps) 3000 3000 3000 5500 5500 5500 5500 Breaking Capacity (Amps) 220/230V 2500 2500 2500 5000 5000 5000 5000 380/400V 2500 2500 2500 5000 5000 5000 5000 500V 2500 2500 2500 5000 5000 5000 5000 660/690V 2500 2500 2500 5000 5000 5000 5000 1000V 760 760 760 950 950 950 950 Short-Circuit Protection Rating Maximum Fuse � Type 2 Coordination 400V; gG/gL 500V 315 315 315 500 500 500 500 690V; gG/gL 690V 315 315 315 500 500 500 500 1000V; gG/gL 1000V 160 160 160 200 200 200 200 � Type 1 Coordination 400V; gG/gL 500V 400 400 400 630 630 630 630 690V; gG/gL 690V 400 400 400 630 630 630 630 1000V; gG/gL 1000V 200 200 200 250 250 250 250 Degree of Protection IP00 Protection Against Direct Contact when Finger- and back-of-hand proof with terminal shroud or terminal block. Actuated from Front (Iec 536) Main Cable Cross-Section 2 Flexible with cable lug (mm ) 35 – 95 50 – 240 50 – 240 50 – 240 50 – 240 50 – 240 50 – 240 2 Stranded with cable lug (mm ) 50 – 120 70 – 240 70 – 240 70 – 240 70 – 240 70 – 240 70 – 240 Solid or Stranded (AWG) 1/0 – 250 MCM 1/0 – 250 MCM 1/0 – 250 MCM 1/0 – 250 MCM 1/0 – 250 MCM 1/0 – 250 MCM � � � � � � Flat Conductor (mm) Busbar — Width in mm 20 20 25 25 25 30 30 Main Cable Connection Screw/Bolt M10 M10 M10 M10 M10 M10 M10 Tightening torque Nm 24 24 24 24 24 24 24 Lb-in 213 213 213 213 213 213 213 Control Circuit Cable Cross-Sections 2 Solid (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) Solid or Stranded (AWG) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) Control Circuit Cable Connection Screw/Bolt M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 Tightening torque Nm 1.2 1.2 1.2 1.2 1.2 1.2 1.2 Lb-in 10.6 10.6 10.6 10.6 10.6 10.6 10.6 Tools Main cable wrench 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm 16 mm Control circuit cable pozidriv screwdriver Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 � Screw tightening with flat cable terminal or cable terminal blocks. See terminal capacity for cable terminal blocks. � IEC 60947 Standard. For more information visit: www.eaton.com CA08102001E 90° IEC Contactors & Starters 34-69 XT IEC Power Control March 2009 Contactors and Starters Table 34-110. XT Contactors Technical Data and Specifications — Frame L – M (Continued) Description XTCE185L, XTCE225L, XTCE250L, XTCE300M, XTCE400M, XTCE500M, XTCE570M, XTCS185L XTCS225L XTCS250L XTCS300M XTCS400M XTCS500M XTCS570M General (Continued) Mounting Position, 30° 30° 30° 30° AC and DC Operated 90° 90° 34 Ambient Temperature -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] Ambient Storage Temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 mS Main contact — NO Contact 10g 10g 10g 10g 10g 10g 10g Auxiliary contact — NO Contact 10g 10g 10g 10g 10g 10g 10g Auxiliary contact — NC Contact 8g 8g 8g 8g 8g 8g 8g Overvoltage Category/ III/3 III/3 III/3 III/3 III/3 III/3 III/3 Pollution Degree � Switching Capacity, kVar Individual Compensation 230V 87 — — 115 — — — 400/420/440V 150 — — 200 — — — 525V 190 — — 265 — — — 690V 150 — — 200 — — — Group Compensation, with Choke 80 100 110 130 160 160 160 230V 150 175 190 225 280 280 280 400/420/440V 200 230 260 290 370 370 370 525V 260 300 340 390 480 480 480 690V Group Compensation, without Choke 66 — — 85 — — — 230V 115 — — 150 — — — 400/420/440V 145 — — 195 — — — 525V 115 — — 150 — — — 690V � When using contactors for group compensation, a minimum inductance of approx. 6 uh per capacitor must be available to limit the high inrush current peaks. This corresponds to an air-cored coil with 5 windings and a coil diameter of approximately 140 mm. The conductor cross-section must be selected according to the rated current per phase. CA08102001E For more information visit: www.eaton.com 90° 180° IEC Contactors & Starters 34-70 XT IEC Power Control March 2009 Contactors and Starters Frame N – R Table 34-111. XT Contactors Technical Data and Specifications — Frame N – R Description XTCE580N XTCE650N XTCE750N, XTCEC10N XTCEC14P XTCEC16R, XTCE820N XTCEC20R General Standards IEC/EN 60947, VDE 0660, UL, CSA Weights in kg [Lb] 15 [33] 15 [33] 15 [33] 15 [33] 15, [33] 32 [70] 34 Mechanical Life 5,000,000 5,000,000 5,000,000 5,000,000 5,000,000 5,000,000 Mechanical Operating Frequency (ops/hr) AC operated 1000 1000 1000 1000 1000 1000 DC operated 1000 1000 1000 1000 1000 1000 Maximum Operating frequency (ops/hr) See Figure 34-45 on Page 34-90. Climatic Proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 Insulation Voltage (Ui) V AC 1000 1000 1000 1000 1000 1000 Impulse Withstand Voltage (U ) V AC 8000 8000 8000 8000 8000 8000 imp Operating Voltage (Ue) V AC 1000 1000 1000 1000 1000 1000 Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and contacts (V AC) 500 500 500 500 500 500 Between contacts (V AC) 500 500 500 500 500 500 Making Capacity (Amps) 7800 7800 9840 9840 9840 19000, 9840 Breaking Capacity (Amps) 220/230V 6500 6500 8200 8200 8200 16000, 8200 380/400V 6500 6500 8200 8200 8200 16000, 8200 500V 6500 6500 8200 8200 8200 16000, 8200 660/690V 6500 6500 8200 8200 8200 16000, 8200 1000V 4350 4350 5800 5800 5800 5800 Short-Circuit Protection Rating Maximum Fuse � Type 2 Coordination 400V; gG/gL 500V 630 630 630 630 — — 690V; gG/gL 690V 630 630 630 630 — — 1000V; gG/gL 1000V 500 500 630 630 — — � Type 1 Coordination 400V; gG/gL 500V 1000 1000 1200 1200 — — 690V; gG/gL 690V 1000 1000 1200 1200 — — 1000V; gG/gL 1000V 630 630 800 800 — — Degree of Protection IP00 Protection Against Direct Contact when Finger- and back-of-hand proof with terminal shroud or terminal block. Actuated from Front (Iec 536) Main Cable Cross-Section 2 Flexible with cable lug (mm ) 50-240 50-240 50-240 50-240 50-240 50-240 2 Stranded with cable lug (mm ) 70-240 70-240 70-240 70-240 70-240 70-240 Solid or Stranded (AWG) 2/0 – 500 MCM 2/0 – 500 MCM 2/0 – 500 MCM 2/0 – 500 MCM 2/0 – 500 MCM 2/0 – 500 MCM � � � � � � Flat Conductor (mm) Busbar — Width in mm 50 50 50 50 50 50 Main Cable Connection Screw/Bolt M10 M10 M12 M12 M12 M12 Tightening torque Nm 24 24 35 35 35 35 Lb-in 213 213 311 311 311 311 Control Circuit Cable Cross-Sections 2 Solid (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) Solid or Stranded (AWG) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) Control Circuit Cable Connection Screw/Bolt M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 Tightening torque Nm 1.2 1.2 1.2 1.2 1.2 1.2 Lb-in 10.6 10.6 10.6 10.6 10.6 10.6 � Screw tightening with flat cable terminal or cable terminal blocks. See terminal capacity for cable terminal blocks. � IEC 60947 Standard. For more information visit: www.eaton.com CA08102001E 90° IEC Contactors & Starters 34-71 XT IEC Power Control March 2009 Contactors and Starters Table 34-111. XT Contactors Technical Data and Specifications — Frame N – R (Continued) Description XTCE580N XTCE650N XTCE750N, XTCEC10N XTCEC14P XTCEC16R, XTCE820N XTCEC20R General (Continued) Tools Main cable wrench 16 mm 16 mm 18 mm 18 mm 18 mm 18 mm Control circuit cable pozidriv screwdriver Size 2 Size 2 Size 2 Size 2 Size 2 Size 2 Mounting Position, AC and DC Operated 30° 30° 34 30° 30° 90° 90° Ambient Temperature -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C -25 to 60°C [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] [-13 to 140°F] Ambient Storage Temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] [-40 to 176°F] Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 mS (g) Main contact — NO Contact 10 10 10 10 10 10 Auxiliary contact — NO Contact 10 10 10 10 10 10 Auxiliary contact — NC Contact 8 8 8 8 8 8 Overvoltage Category/Pollution Degree III/3 III/3 III/3 III/3 III/3 III/3 � Switching Capacity, kVar Individual Compensation 230V 175 — — — — — 400/420/440V 300 — — — — — 525V 400 — — — — — 690V 300 — — — — — � When using contactors for group compensation, a minimum inductance of approx. 6 uh per capacitor must be available to limit the high inrush current peaks. This corresponds to an air-cored coil with 5 windings and a coil diameter of approximately 140 mm. The conductor cross-section must be selected according to the rated current per phase. Instructional Leaflets Table 34-112. Instructional Leaflets Publication Number Description Pub51210 7 – 15A, B Frame XTCE, XTCEC and XTCF Contactors and Accessories (Inside of Packaging) Pub51211 18 – 32A, C Frame XTCE and XTCEC Contactors and Accessories (Inside of Packaging) Pub51221 XTOB, D Frame Overload Relays (Inside of Packaging) Pub51222 XTOB, B – C Frame Overload Relays (Inside of Packaging) Pub51237 7 – 12A, B Frame XTCE Contactors and Auxiliary Contacts Pub51232 18 – 32A, C Frame XTCE Contactors and Auxiliary Contacts Pub51216 40 – 65A, D Frame XTCE Contactors and Auxiliary Contacts Pub51203 185 – 500A, L – M Frame XTCE Contactors and Auxiliary Contacts Pub51215 S-Series 185 – 500A, L – M Frame XTCE Contactors and Auxiliary Contacts Pub51204 580 – 1000A, N Frame XTCE Contactors and Auxiliary Contacts Pub51209 1400 – 2000A, P – R Frame XTCE Contactors and Auxiliary Contacts Pub51213 7 – 150A, B – G Frame XTAE Non-reversing and XTAR Reversing Starters Pub51217 XTCEXFA and XTCEXSA Front and Side Mount Auxiliary Contacts from 40 – 150A, D – G Frame XTCE Contactors Pub51212 XTCEXML Mechanical Interlock for 7 – 150A, B – G Frame XTCE Contactors Pub51214 XTCEXRL Reversing Link Kits for 18 – 32A, C Frame XTCE Contactors Pub51218 XTCEXTL Lug Kits for 500 – 820A, M – N Frame XTCE Contactors Pub51219 XTCEXRLB and XTCEXSDLB Reversing and Star-Delta (Wye-Delta) Link Kits for 7 – 12A, B Frame XTCE Contactors Pub51205 Accessories for 185 – 500A, L – M Frame XTCE Contactors Pub51207 Replacement DC Coils Pub51213 Renewal Parts — Coils for 18 – 32A, C Frame XTCE Contactors Pub51186 Renewal Parts — Coils for 40 – 65A, D Frame XTCE Contactors CA08102001E For more information visit: www.eaton.com 90° 180° IEC Contactors & Starters 34-72 XT IEC Power Control March 2009 Contactors and Starters Coil Data Frame B – D Table 34-113. Coil Data — Frame B – D Description XTCE007B XTCE009B XTCE012B, XTCE015B XTCE018C XTCE025C XTCE032C XTCE040D XTCE050D XTCE065D, XTCF020B XTCE072D Voltage Tolerance 34 Pick-Up (x U ) c AC operated 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 � � � � � � � � � � DC operated 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2 Drop-Out (x U ) c AC operated 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 0.3 – 0.6 DC operated 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 Power Consumption of the coil at cold state and 1.0 x U c AC operated Single-voltage coil 50 Hz Pick-Up VA 24 24 24 24 52 52 52 149 149 149 Pick-Up W 19 19 19 19 40 40 40 80 80 80 Sealing VA 3.4 3.4 3.4 3.4 7.1 7.1 7.1 16 16 16 Sealing W 1.2 1.2 1.2 1.2 2.1 2.1 2.1 4.3 4.3 4.3 Single-voltage coil 60 Hz Pick-Up VA 30 30 30 30 67 67 67 178 178 178 Pick-Up W 23 23 23 23 50 50 50 117 117 117 Sealing VA 4.4 4.4 4.4 4.4 8.7 8.7 8.7 19 19 19 Sealing W 1.4 1.4 1.4 1.4 2.6 2.6 2.6 5.3 5.3 5.3 50/60 Hz Pick-Up VA 27 27 27 27 62 62 62 168 168 168 25 25 25 25 58 58 58 154 154 154 Pick-Up W 22 22 22 22 48 48 48 120 120 120 21 21 21 21 43 43 43 43 43 43 Sealing VA 4.2 4.2 4.2 4.2 9.1 9.1 9.1 22 22 22 3.3 3.3 3.3 3.3 6.5 6.5 6.5 14 14 14 Sealing W 1.4 1.4 1.4 1.4 2.5 2.5 2.5 5.3 5.3 5.3 1.2 1.2 1.2 1.2 2 2 2 4.3 4.3 4.3 DC operated Pick-Up W 3 3 4.5 4.5 12 at 24V 12 at 24V 12 at 24V 24 at 24V 24 at 24V 24 at 24V Sealing W 3 3 4.5 4.5 0.5 at 24V 0.5 at 24V 0.5 at 24V 0.5 at 24V 0.5 at 24V 0.5 at 24V Duty Factor (%DF) 100 100 100 100 100 100 100 100 100 100 Switching Time at 100% U (approximate values) c Main Contact AC operated Closing delay (mS) <21 <21 <21 <21 <22 <22 <22 <18 <18 <18 Opening delay (mS) <18 <18 <18 <18 <14 <14 <14 <13 <13 <13 DC operated Closing delay (mS) <31 <31 <31 <31 <47 <47 <47 <54 <54 <54 Opening delay (mS) <12 <12 <12 <12 <30 <30 <30 <24 <24 <24 Arcing time (mS) 10 10 10 10 10 10 10 10 10 10 Electromagnetic Compatibility (EMC) Emitted interference To EN-60947-1 Noise Immunity To EN-60947-1 � 0.7 – 1.3 without additional auxiliary contact modules and ambient temperature +40°C [104°F]. � Coil Suffix TD: U 24V DC/U 27V DC. min max Coil Suffix WD: U 48V DC/U 60V DC. min max Coil Suffix AD: U 110V DC/U 130V DC. min max Coil Suffix BD: U 200V DC/U 240V DC. min max Example: U = 0.7 x U — 1.2 x U c min max U = 0.7 x 24V — 1.2 x 27V DC c For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-73 XT IEC Power Control March 2009 Contactors and Starters Frame F – G Table 34-114. Coil Data — Frame F – G Description XTCE80F XTCE95F XTCE115G XTCE150G XTCE170G Voltage Tolerance Pick-Up (x U ) c AC operated 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 � � � � � DC operated 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2 0.7 – 1.2 Drop-Out (x U ) 34 c AC operated 0.3 – 0.6 0.3 – 0.6 0.25 – 0.6 0.25 – 0.6 0.25 – 0.6 DC operated 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 0.15 – 0.6 Power Consumption of the coil at cold state and 1.0 x U c AC operated Single-voltage coil 50 Hz Pick-Up VA 310 310 180 180 180 Pick-Up W 165 165 130 130 130 Sealing VA 26 26 3.1 3.1 3.1 Sealing W 5.8 5.8 2.1 2.1 2.1 Single-voltage coil 60 Hz Pick-Up VA 345 345 170 170 170 Pick-Up W 190 190 130 130 130 Sealing VA 30 30 3.1 3.1 3.1 Sealing W 7.1 7.1 2.1 2.1 2.1 50/60 Hz Pick-Up VA 372 328 170 170 170 Pick-Up W 190 190 130 130 130 Sealing VA 37.1 22.6 3.1 3.1 3.1 Sealing W 7.5 6.1 2.1 2.1 2.1 DC operated Pick-Up W 90 at 24V 90 at 24V 149 at 24V 149 at 24V 149 at 24V Sealing W 1.3 at 24V 1.3 at 24V 2.1 at 24V 2.1 at 24V 2.1 at 24V Duty Factor (%DF) 100 100 100 100 100 Switching Time at 100% U (approximate values) c Main Contact AC operated Closing delay (mS) <20 <20 <33 <33 <33 Opening delay (mS) <14 <14 <41 <41 <41 DC operated Closing delay (mS) <45 <45 <35 <35 <35 Opening delay (mS) <34 <34 <30 <30 <30 Arcing Time (mS) 15 15 15 15 15 Permissible Residual Current with Actuation of A1 ≤1 ≤1 ≤1 ≤1 ≤1 – A2 By the Electronics (with 0 signal) (mA) Electromagnetic Compatibility (EMC) Emitted interference To EN60947-1 Noise Immunity To EN60947-1 � At 24V: 0.7 – 1.3 without additional auxiliary contact modules and ambient temperature +40°C [104°F]. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-74 XT IEC Power Control March 2009 Contactors and Starters Frame L – R Table 34-115. Coil Data — Frame L – R Description XTCE185L, XTCS185L XTCE225L, XTCE250L, XTCE300M, XTCE400M, XTCE500M, XTCS500M, XTCS250L XTCS300M XTCE570M, XTCS570M Voltage Tolerance Pick-Up (x U ) c XTCE185L – XTCEC20R 0.7 x U — 1.15 x U cmin cmax 34 XTCS185L – XTCS500M 0.85 x U — 1.1 x U cmin cmax Drop-Out (x U ) c XTCE185L – XTCEC20R 0.2 x U — 0.6 x U cmin cmax XTCS185L – XTCS500M 0.2 x U — 0.4 x U cmin cmax Power Consumption of the coil at cold state and 1.0 x U c XTCE185L – XTCEC20R � � � � Pick-Up VA 250 250 450 450 Pick-Up W 200 200 350 350 Sealing VA 4.3 4.3 4.3 4.3 Sealing W 3.3 3.3 3.3 3.3 XTCS185L – XTCS500M Pick-Up VA 360 360 715 715 Pick-Up W 325 325 645 645 Sealing VA 4.3 4.3 4.3 4.3 Sealing W 3.3 3.3 3.3 3.3 Duty Factor (%DF) 100 100 100 100 Switching Time at 100% Main Contact U (approximate values) c XTCE185L – XTCEC20R Closing delay (mS) <100 <100 <80 <80 Opening delay (mS) <80 <80 <80 <80 XTCS185L – XTCS500M Closing delay (mS) <50 <50 <50 <50 Opening delay (mS) <40 <40 <40 <40 Reaction in Threshold and Sealing State Transition Range (XTCE185L – XTCEC20R) Voltage interruptions (0 – 0.2 x U ) ≤ 10ms Time is bridged successfully cmin (0 – 0.2 x U ) > 10ms Drop-out of the contactor cmin Voltage Dips (0.2 – 0.6 x U ) ≤ 12ms Time is bridged successfully cmin (0.2 – 0.6 x U ) > 12ms Drop-out of the contactor cmin (0.6 – 0.7 x U ) Contactor remains switched on cmin Excess Voltage (1.15 – 1.3 x U ) Contactor remains switched on cmax (>1.3 x U ) ≤ 3s Contactor remains switched on cmax (>1.3 x U ) > 3s Drop-out of the contactor cmax Pick – Up phase (0 – 0.7 x U ) Contactor does not switch on cmin (0.7 x U –1.15 x U ) Contactor switches on with certainty cmin cmax (>1.15 x U ) Contactor switches on with certainty cmax Permissible contact resistance (of the external ≤500 ≤500 ≤500 ≤500 command device with actuation of A11), Ω Permissible residual current (with actuation of ≤1 ≤1 ≤1 ≤1 A11 by the electronics with 0 signal) SPS Signal Level (A3 – A4) to IEC/EN 61131-2 (Type 2) High 15V 15V 15V 15V Low 5V 5V 5V 5V Electromagnetic compatibility (EMC) This product is designed for operation in industrial environments. Usage in domestic areas can cause radio frequency interference (RFI). Noise suppression measures must be provided for the additional interference. � Control transformer with U ≤6%. k For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-75 XT IEC Power Control March 2009 Contactors and Starters Table 34-115. Coil Data — Frame L – R (Continued) Description XTCE580N XTCE750N, XTCE820N XTCEC10N XTCEC14P XTCE16R, XTCEC20R Voltage Tolerance Pick-Up (x U ) c XTCE185L – XTCEC20R 0.7 x U — 1.15 x U cmin cmax XTCS185L – XTCS500M 0.85 x U — 1.1 x U cmin cmax Drop-Out (x U ) c XTCE185L – XTCEC20R 0.2 x U — 0.6 x U cmin cmax XTCS185L – XTCS500M 0.2 x U — 0.4 x U 34 cmin cmax Power Consumption of the coil at cold state and 1.0 x U c XTCE185L – XTCEC20R � � � � � Pick-Up VA 800 800 800 800 1600 Pick-Up W 700 700 700 700 1400 Sealing VA 7.5 7.5 7.5 7.5 15 Sealing W 6.5 6.5 6.5 6.5 13 XTCS185L -– XTCS500M Pick-Up VA — — — — — Pick-Up W — — — — — Sealing VA — — — — — Sealing W — — — — — Duty Factor (%DF) 100 100 100 100 100 Switching Time at 100% Main Contact U (approximate values) c XTCE185L – XTCEC20R Closing delay (mS) <70 <70 <70 <70 <70 Opening delay (mS) <70 <70 <70 <40 <40 XTCS185L – XTCS500M Closing delay (mS) — — — — — Opening delay (mS) — — — — — Reaction in Threshold and Sealing State Transition Range (XTCE185L – XTCEC20R) Voltage interruptions (0 – 0.2 x U ) ≤ 10ms Time is bridged successfully cmin (0 – 0.2 x U ) > 10ms Drop-out of the contactor cmin Voltage Dips (0.2 – 0.6 x U ) ≤ 12ms Time is bridged successfully cmin (0.2 – 0.6 x U ) > 12ms Drop-out of the contactor cmin (0.6 – 0.7 x U ) Contactor remains switched on cmin Excess Voltage (1.15 – 1.3 x U ) Contactor remains switched on cmax (>1.3 x U ) ≤ 3s Contactor remains switched on cmax (>1.3 x U ) > 3s Drop-out of the contactor cmax Pick – Up phase (0 – 0.7 x U ) Contactor does not switch on cmin (0.7 x U –1.15 x U ) Contactor switches on with certainty cmin cmax (>1.15 x U ) Contactor switches on with certainty cmax Permissible contact resistance (of the external ≤500 ≤500 ≤500 ≤500 ≤500 command device with actuation of A11), Ω Permissible residual current (with actuation of ≤1 ≤1 ≤1 ≤1 ≤1 A11 by the electronics with 0 signal) SPS Signal Level (A3 – A4) to IEC/EN 61131-2 (Type 2) High 15V 15V 15V 15V 15V Low 5V 5V 5V 5V 5V Electromagnetic compatibility (EMC) This product is designed for operation in industrial environments. Usage in domestic areas can cause radio frequency interference (RFI). Noise suppression measures must be provided for the additional interference. � Control transformer with U ≤7%. k CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-76 XT IEC Power Control March 2009 Contactors and Starters Contactor Contact Travel Diagrams The diagrams indicate the closing and travel of the contacts of the contactors and auxiliary contacts at no-load. Tolerances are not taken into consideration. Frame B XTCE 7 – 15A, XTCF — AC XTCE 7 – 9A — DC XTCE 12 – 15A, XTCF — DC 34 NO contact NO contact NO contact 0 3.3 4.5 0 2.1 2.9 0 3.3 4.4 NC contact NC contact NC contact 0 4.5 0 2.9 0 4.4 1.0 0.7 1.0 XTCEXSAC11 XTCEXSAC11 XTCEXSAC11 NO contact NO contact NO contact 0 3.2 4.5 0 2.3 2.9 0 3.2 4.4 NC contact NC contact NC contact 0 4.5 0 2.9 0 4.4 1.6 0.7 1.6 XTCEXF...LC... XTCEXF...LC... XTCEXF...LC... NO contact NO contact NO contact 0 2.0 4.5 0 1.1 2.9 0 2.0 4.4 NC contact NC contact NC contact 0 2.8 4.5 0 1.9 2.9 0 2.8 4.4 Frame C Frame D Frame F and G XTCE 15 – 32A XTCE 40 – 72A XTCE 80 – 170A NO contact NO contact NO contact 0 8 11 0 4 6.0 0 5.1 7.5 Auxiliary NC 1.8 XTCEXF...G... XTCEXF...G... Auxiliary NO 3.2 NO contact NO contact 0 5.7 7.5 0 9.2 11 NC contact NC contact 0 3.9 7.5 0 7.4 11 XTCEXSAC11, XTCEXF...C... NO contact 0 3.2 6 XTCEXF...LG... XTCEXF...LG... NC contact 0 1.6 6 NO contact NO contact 0 3.8 7.5 0 7.3 11 NC contact NC contact 0 5.4 7.5 0 8.9 11 XTCEXF...LC... NO contact 0 2.0 6 XTCEXS...N... XTCEXS...N... NC contact 0 2.8 6 NO contact NO contact 0 5.45 7.5 0 8.95 11 NC contact NC contact 0 3.6 7.5 0 7.1 11 XTCEXSBLN11 XTCEXSBLN11 NO contact NO contact 0 4.1 7.5 0 7.6 11 NC contact NC contact 0 4.95 7.5 0 8.45 11 Figure 34-38. Contactor Contact Travel Diagrams For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-77 XT IEC Power Control March 2009 Contactors and Starters Table 34-116. XT Contactors Technical Data and Specifications — 4-Pole Description XTCF020B XTCF032C XTCF045C XTCF063D XTCF080D XTCF125G XTCF160G XTCF200G General Standards IEC/EN 60947, VDE 0660, UL, CSA Weights in kg [Lb] AC operated 0.22 [0.49] 0.49 [1.1] 1.0 [2.3] 2.8 [6.2] DC operated 0.29 [0.64] 0.49 [1.1] 1.0 [2.3] 2.8 [6.2] Mechanical Life 10,000,000 34 Mechanical Operating Frequency (ops/hr) AC operated 5000 3600 DC operated 5000 3600 Electrical Life See Curve, Page 34-88 Electrical Operating Frequency (ops/hr) 600 Climatic Proofing Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclical, to IEC 60068-2-30 Insulation Voltage (Ui) V AC 690 Impulse Withstand Voltage (Uimp) V AC 8000 Operation Voltage (Ue) V AC 690 Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and contacts (V AC) 400 440 Between contacts (V AC) 400 440 Making Capacity Up to 690V (Amps) 144 238 350 560 700 1120 1330 1800 Breaking Capacity (Amps) 220/230V 120 180 250 00 00 800 950 1150 380/400V 120 180 250 400 500 800 950 1150 500V 100 180 250 400 500 800 950 1150 660/690V 70 120 144 250 296 650 750 800 Short Circuit Protection Rating Maximum Fuse Type 2 Coordination 400V; gG/gL 500V 20 35 35 63 80 160 160 250 690V; gG/gL 690V 20 35 35 50 63 160 160 200 Type 1 Coordination 400V; gG/gL 500V 35 63 100 125 160 250 250 250 690V; gG/gL 690V 25 50 50 80 80 200 200 200 Degree of Protection IP20 IP00 with Accessories — IP20 Protection against Direct Contact when Finger- and back-of-hand proof Actuated from Front (IEC 536) Terminal Capacity Main Cable - Screw Terminals 2 Solid (mm ) 1 x (0.75 – 4) 1 x (0.75 – 16) 1 x (2.5 –16) — 2 x (0.75 – 2.5) 2 x (0.75 –10) 2 x (2.5 –16) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 1 x (0.75 – 16) 1 x (2.5 – 35) 1 x (10 –95) 2 x (0.75 – 2.5) 2 x (0.75 – 10) 2 x (2.5 – 25) 2 x (10 – 70) Solid or Stranded (AWG) 18 – 14 18 – 6 12 – 2 8 - 250MCM Terminal Capacity Control Circuit Cable — Screw Terminals 1 x (0.75 – 4) 2 Solid (mm ) 2 x (0.75 – 2.5) 2 Flexible with ferrule (mm ) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) Solid or Stranded (AWG) 18 – 14 Main Cable Connection Screw/Bolt Tightening torque Nm 1.2 3 3.3 14 Lb-in 10.6 26.6 29.2 123.9 Control Circuit Cable Connection Screw/Bolt Tightening torque Nm 1.2 Lb-in 10.6 Tools Main and Control Circuit Cable — Screw Terminals 2 — Pozidriv screwdriver 0.8 x 5.5 — Standard screwdriver 1 x 6 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-78 XT IEC Power Control March 2009 Contactors and Starters Table 34-116. XT Contactors Technical Data and Specifications — 4-pole (Continued) Description XTCF020B XTCF032C XTCF045C XTCF063D XTCF080D XTCF125G XTCF160G XTCF200G General Mounting Position, AC & DC Operated 34 Ambient Temperature Open -25 to 60°C [-13 to 140°F] Enclosed -25 to 40°C [-13 to 104°F] Ambient Storage Temperature -40 to 80°C [-40 to 176°F] Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 mS Main contact - NO Contact 10g Auxiliary contact - NO Contact 7g Auxiliary contact - NC Contact 5g Overvoltage Category/Pollution Degree III/3 Coil Data Voltage Tolerance Pick-Up (x Uc) AC operated 0.8 – 1.1 0.8 – 1.1 DC operated 0.8 – 1.1 0.7 – 1.2 Drop-Out (x Uc) AC operated 0.4 – 0.6 0.4 – 0.6 DC operated 0.2 – 0.6 0.2 – 0.6 Power Consumption of the Coil at Cold State and 1.0 x Uc AC operated 50/50Hz Pick-up VA 24 50 150 180 Pick-up W 19 40 95 150 Sealing VA 4 8 16 3.1 Sealing W 1.2 2.4 4 2.1 DC operated Pick-up W 4.5 12 24 149 Sealing W 4.5 0.5 0.5 2.1 Duty Factor (%DF) 100 Switching Time at 100% Uc (Approximate Values) Main Contact AC operated Closing delay (mS) 15 to 21 6 to 22 12 to 18 28 to 33 Opening delay (mS) 9 to 18 8 to 14 8 to 13 35 to 41 DC operated Closing delay (mS) 31 47 54 35 Opening delay (mS) 12 30 24 30 Arcing Time (mS) 10 10 10 15 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-79 XT IEC Power Control March 2009 Contactors and Starters Auxiliary Contacts Table 34-117. Auxiliary Contacts Technical Data and Specifications Description XTCE007B…– XTCEXFAC… XTCEXFCC… XTCEXFAG… XTCEXSBLN… XTCE032C XTCEXFATC... XTCEXSCC... XTCEXSBN… XTCEXSBNC... XTCEXSCN… XTCEXSCNC… Interlocked opposing contacts with an auxiliary — Yes Yes Yes Yes 34 contact module (to IEC 60947-5 -1 Annex L) Break contact (not late-break contact) XTCE007B… – XTCE007B… – XTCE007B… – XTCE040D… – XTCE040D… – suitable as a mirror contact XTCE032C XTCE032C XTCE032C XTCE065D… XTCE065D… (to IEC/EN 60947-4 -1 Annex F) XTCE185L… – XTCEC10N… Rated impulse withstand voltage, (Uimp) V AC 6000 6000 6000 6000 6000 Overvoltage category / pollution degree III/3 III/3 III/3 III/3 III/3 Rated insulation voltage, (Ui) V AC 690 690 690 690 690 Rated operational voltage, (U ) V AC 500 500 500 500 500 e Safe isolation to VDE 0106 Part 101 and Part 101(A) in V AC Between coil and auxiliary contacts 400 400 400 440 440 Between the auxiliary contacts 400 400 400 440 440 Rated Operational Current, l e AC-15 230V 6A 6A 6A 6A 6A 380/415V 4A 3A 4A 4A 4A 500V 1.5A — 1.5A 1.5A 1.5A � DC-3 L/R ≤5 mS 24V 10A 10A 10A 10A 10A 60V 6A 6A 6A 6A 6A 110V 3A 3A 3A 3A 3A 220V 1A 1A 1A 1A 1A � Conventional thermal current, I 16A 16A 16A 10A 10A th -8 Control circuit reliability <10 , < one failure at 100 million operations (at U = 24 V DC, U = 17 V, I = 5.4 mA) e min min 6 Component Lifespan, Operations x 10 at U = 230V, AC-15, 3A 1.3 1.3 1.3 1.3 1.3 e � Short-circuit rating without welding Maximum fuse, gG/gL 10A 10A 10A 16A 16A � Making and breaking conditions to DC-13, time L/R contact as stated. � See fuses overlay for time/current characteristic (on request). � Conventional thermal current (I ) of XTCEXSCC_ is 10A. th Table 34-118. Parallel Link Technical Data and Specifications Description XTCEXPLKB XTECXPLKC XTCEXPLKD XTCEXPLKG XTCEXPLK185 Terminal Capacity 2 Solid (mm ) 1 – 16 16 16 — — 2 Flexible with ferrule (mm ) 1 x (0.5 – 25) 1 x (16 – 35) 1 x (16 – 120) — — 2 x (0.5 – 16) 2 Stranded (mm ) 1 x (0.5 – 25) 1 x (16 – 50) 1 x (16 – 120) 1 x (35 – 300) — 2 x (0.5 – 16) 2 x (35 – 120) Flat conductor — 6 x 9 x 0.8 — — 2 x (11 x 21 x 1) 1 x (6 x 16 x 0.8) number of segments x width x thickness (mm) 2 x (20 x 32 x 0.5) 2 x (11 x 21 x 1) Tightening Torque (Nm) 4 4 14 — — Tools Pozidriv screwdriver Size 2 Size 2 — — — Hexagon socket head spanner — SW (mm) — — 5 6 — Conventional Thermal Current 3-Pole (I ) A 50 100 180 400 — th 4-Pole (I ) A 60 — — — — th Table 34-119. Cable Terminal Block, Flat Cable Terminal Technical Data and Specifications Description XTCEXTLA400 XTCEXPLK185 XTCEXTFB650 XTCEXTFB820 Terminal Capacity 2 Stranded (mm ) 1 x (120 – 300) ——— 2 x (70 – 240) Stranded (AWG) 1 x (1/0 – 600 MCM)——— 2 x (1/0 – 500 MCM) Flat conductor — 1 x (10 x 16 x 0.8) 1 x (6 x 16 x 0.8) 1 x (6 x 16 x 0.8) 1 x (6 x 16 x 0.8) number of segments x width x thickness (mm) 2 x (20 x 24 x 0.5) 2 x (20 x 32 x 0.5) 2 x (20 x 32 x 0.5) 2 x (10 x 40 x 1) 2 x (11 x 21 x 1) 2 x (11 x 21 x 1) 2 x (11 x 21 x 1) 2 x (20 x 40 x 0.5) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-80 XT IEC Power Control March 2009 Contactors and Starters AC Ratings Table 34-120. AC Ratings Description XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 – 60 Hz Open 34 at 40°C (I ) 22A 22A 22A 22A 40A 45A 45A th at 50°C (I ) 21A 21A 21A 21A 38A 43A 43A th at 55°C (I ) 21A 21A 21A 21A 37A 42A 42A th at 60°C (I ) 20A 20A 20A 20A 35A 40A 40A th Enclosed 18A 18A 18A 18A 32A 36A 36A Conventional Free Air Thermal Current, 1-Pole (I ) th Open 50A 50A 50A 50A 88A 100A 100A Enclosed 45A 45A 45A 45A 80A 90A 90A AC-3 Operation � Rated Operational Current, 50/60 Hz (I ) e in amperes 220/230V 7 9 12 15.5 18 25 32 240V 7 9 12 15.5 18 25 32 380/400V 7 9 12 15.5 18 25 32 415V 7 9 12 15.5 18 25 32 440V 7 9 12 15.5 18 25 32 500V 5 7 10 12.5 18 25 32 660/690V 4 5 7 9 12 15 18 1000V — — — — — — — Rated power (P) in kilowatts 220/230V 2.2 2.5 3.5 4 5 7.5 10 240V 2.2 3 4 4.6 5.5 8.5 11 380/400V 3 4 5.5 7.5 7.5 11 15 415V 4 5.5 7 8 10 14.5 19 440V 4.5 5.5 7.5 8.4 10.5 15.5 20 500V 3.5 4.5 7 7.5 12 17.5 23 660/690V 3.5 4.5 6.5 7 11 14 17 1000V — — — — — — — AC-4 Operation � Rated Operational Current, 50/60 Hz (I ) e in amperes 220/230V 5 6 7 10 13 15 240V 5 6 7 7 10 13 15 380/400V 5 6 7 7 10 13 15 415V 5 6 7 7 10 13 15 440V 5 6 7 7 10 13 15 500V 4.5 5 6 6 10 13 15 660/690V 4 4.5 5 5 8 10 12 1000V — — — — — — — Rated power (P) in kilowatts 220/230V 1 1.5 2 2 2.5 3.5 4 240V 1.5 1.6 2.2 2.2 3 4 4.5 380/400V 2.2 2.5 3 3 4.5 6 7 415V 2.3 2.8 3.4 3.4 5 6.5 7.5 440V 2.4 3 3.6 3.6 5.5 7 8 500V 2.5 2.8 3.5 3.5 6 8 9 660/690V 2.9 3.6 4.4 4.4 6.5 8.5 10 1000V — — — — — — — AC-6A Operation Transformer Loads Values are application specific. Calculation is I AC-3 = X / 6 * Ie Transformer where X is the inrush current of the e � transformer and Ie Transformer is the nominal current. AC-6B Operation Capacitor Loads Individual compensation rated operational cur- rent I of three-phase capacitors in amperes e Up to 525V See Page 34-48 for Capacitor Ratings 690V Maximum inrush current peak (x I) 30303030303030 e Component Lifesaving (Operations) — — — — — — — Maximum Operating Frequency (ops/hr) — — — — — — — � At maximum permissible ambient temperature. � Example — The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-81 XT IEC Power Control March 2009 Contactors and Starters Table 34-120. AC Ratings (Continued) Description XTCE040D XTCE050D XTCE065D XTCE072D XTCE080F XTCE095F XTCE115G XTCE150G XTCE170G AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 – 60 Hz Open � at 40°C (I ) 60A 80A 98A 98A 110A 130A 160A 190A 275A th at 50°C (I ) 57A 71A 88A 88A 98A 125A 142A 180A 200A th at 55°C (I ) 55A 68A 83A 83A 94A 115A 135A 170A 190A 34 th at 60°C (I ) 50A 65A 80A 80A 90A 110A 130A 160A 185A th Enclosed 45A 58A 72A 72A 80A 100A 115A 144A 166A Conventional Free Air Thermal Current, 1-Pole (I ) th Open 125A 162A 200A 200A 225A 275A 325A 400A 460A Enclosed 112A 145A 180A 180A 200A 250A 285A 360A 415A AC-3 Operation � Rated Operational Current, 50/60 Hz (I ) e in amperes 40 50 65 72 80 95 115 150 170 220/230V 40 50 65 72 80 95 115 150 170 240V 40 50 65 72 80 95 115 150 170 380/400V 40 50 65 72 80 95 115 150 170 415V 40 50 65 72 80 95 115 150 170 440V 40 50 65 72 80 95 115 150 170 500V 25 32 37 37 65 80 93 100 150 660/690V — — — — — — — — — 1000V Rated power (P) in kilowatts 220/230V 12.5 15.5 20 22 25 30 37 48 52 240V 13.5 17 22 35 27.5 34 40 52 57 380/400V 18.5 22 30 37 37 45 55 75 90 415V 24 30 39 41 43 57 70 91 100 440V 25 32 41 44 51 60 75 95 105 500V 28 36 47 45 58 70 85 110 120 660/690V 23 30 35 35 63 75 90 96 140 1000V — — — — — — — — — AC-4 Operation � Rated Operational Current, 50/60 Hz (I ) e in amperes 18 21 25 25 40 50 55 65 65 220/230V 18 21 25 25 40 50 55 65 65 240V 18 21 25 25 40 50 55 65 65 380/400V 18 21 25 25 40 50 55 65 65 415V 18 21 25 25 40 50 55 65 65 440V 18 21 25 25 40 50 55 65 65 500V 14 17 20 20 40 50 45 50 50 660/690V — — — — — — — — — 1000V Rated power (P) in kilowatts 220/230V 5 6 7 7 12 16 17 20 20 240V 5.5 6.5 7.5 7.5 13 17 19 22 22 380/400V 9 10 12 12 20 26 28 33 33 415V 9.5 11 13 13 24 30 33 39 39 440V 10 12 14 14 25 32 35 41 41 500V 11 13 16 16 29 36 40 47 47 660/690V 12 14 17 17 26 35 43 48 48 1000V — — — — — — — — — AC-6A Operation Transformer Loads Values are application specific. Calculation is I AC-3 = X / 6 * Ie Transformer where X is the inrush current e � of the transformer and Ie Transformer is the nominal current. AC-6B Operation Capacitor Loads Individual compensation rated operational current I of three-phase e capacitors in amperes See Page 34-48 for Capacitor Ratings Up to 525V 690V Maximum inrush current peak (x I) 3030303030 30 303030 e Component Lifesaving (Operations) — — — — — — — — — Maximum Operating Frequency (ops/hr)— — — — — — — — — � 2 For 225 – 275A, use 2X 70 mm wire. � At maximum permissible ambient temperature. � Example — The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-82 XT IEC Power Control March 2009 Contactors and Starters Table 34-120. AC Ratings (Continued) Description XTCE185L XTCE225L XTCE250L XTCE300M XTCE400M XTCE500M XTCE570M XTCE580N AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 – 60 Hz at 40°C (I ) 337 386 429 490 612 857 857 980 th at 50°C (I ) 301 345 383 438 548 767 767 876 th at 55°C (I ) 287 329 366 418 522 731 731 836 th 34 at 60°C (I ) 275 315 350 400 500 700 700 800 th Conventional Free Air Thermal Current, 685 785 875 1000 1250 1750 1750 2000 1-Pole (I ) th AC-3 Operation � Rated Operational Current, 50/60 Hz (I ) e in amperes 220/230V 185 225 250 300 400 500 580 580 240V 185 225 250 300 400 500 580 580 380/400V 185 225 250 300 400 500 580 580 415V 185 225 250 300 400 500 580 580 440V 185 225 250 300 400 500 580 580 500V 185 225 250 300 400 500 580 580 660/690V 185 225 250 300 400 500 580 580 1000V 76 76 76 95 95 95 95 435 Rated power (P) in kilowatts 220/230V 55 70 75 90 125 155 185 185 240V 62 75 85 100 132 170 200 200 380/400V 90 110 132 160 200 250 315 315 415V 110 132 148 180 240 300 348 348 440V 115 142 157 190 255 345 370 370 500V 132 160 180 215 290 360 420 420 660/690V 175 215 240 286 344 344 344 560 1000V 108 108 108 132 132 132 132 600 AC-4 Operation � Rated Operational Current, 50/60 Hz (I ) e in amperes 220/230V 136 164 200 240 296 360 360 456 240V 136 164 200 240 296 360 360 456 380/400V 136 164 200 240 296 360 360 456 415V 136 164 200 240 296 360 360 456 440V 136 164 200 240 296 360 360 456 500V 136 164 200 240 296 360 360 456 660/690V 136 164 200 240 296 296 296 456 1000V 76 76 76 95 95 95 95 348 Rated power (P) in kilowatts 220/230V 41 51 62 75 92 112 112 143 240V 45 54 68 82 101 122 122 156 380/400V 75 90 110 132 160 200 200 250 415V 80 96 117 142 176 216 216 274 440V 85 102 125 151 186 229 229 290 500V 96 116 143 172 214 260 260 330 660/690V 127 155 189 229 283 344 344 440 1000V 108 108 108 132 132 132 132 509 AC-6A Operation Transformer Loads Values are application specific. Calculation is I AC-3 = X / 6 * Ie Transformer where X e � is the inrush current of the transformer and Ie Transformer is the nominal current. AC-6B Operation Capacitor Loads Individual compensation rated operational current I of three-phase capacitors in amperes e Up to 525V 220 220 220 307 307 307 307 463 690V 133 133 133 177 177 177 177 265 Maximum inrush current peak (x I ) 30 30 30 30 30 30 30 30 e Component Lifesaving (Operations) 100,000 100,000 100,000 100,000 100,000 100,000 100,000 100,000 Maximum Operating Frequency (ops/hr) 200 200 200 200 200 200 200 200 � At maximum permissible ambient temperature. � Example — The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-83 XT IEC Power Control March 2009 Contactors and Starters Table 34-120. AC Ratings (Continued) Description XTCE650N XTCE750N XTCE820N XTCEC10N XTCEC14P XTCEC16R XTCEC20R AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 – 60 Hz � � at 40°C (I ) 1041 1102 1225 1225 1714 2200 2450 th � � at 50°C (I ) 931 986 1095 1095 1533 1970 2190 th � � at 55°C (I ) 888 940 1044 1044 1462 1800 2089 th � � at 60°C (I ) 850 900 1000 1000 1400 1800 2000 34 th Conventional Free Air Thermal Current, 2125 2250 2500 2500 3500 4500 5000 1-Pole (I ) th AC-3 Operation � Rated Operational Current, 50/60 Hz (I ) e in amperes 220/230V 650 750 820 1000 — 1600 — 240V 650 750 820 1000 — 1600 — 380/400V 650 750 820 1000 — 1600 — 415V 650 750 820 1000 — 1600 — 440V 650 750 820 1000 — 1600 — 500V 650 750 820 1000 — 1600 — 660/690V 650 750 820 1000 — 1600 — 1000V 435 580 580 700 — — — Rated power (P) in kilowatts 220/230V 205 240 260 315 — 500 — 240V 225 260 285 340 — 550 — 380/400V 355 400 450 560 — 900 — 415V 390 455 500 610 — 930 — 440V 420 480 525 650 — 1000 — 500V 470 550 600 730 — 1180 — 660/690V 630 720 750 1000 — 1600 — 1000V 600 800 800 1000 — — — AC-4 Operation � Rated Operational Current, 50/60 Hz (I ) e in amperes 220/230V 512 576 656 800 — 1280 — 240V 512 576 656 800 — 1280 — 380/400V 512 576 656 800 — 1280 — 415V 512 576 656 800 — 1280 — 440V 512 576 656 800 — 1280 — 500V 512 576 656 800 — 1280 — 660/690V 512 576 656 800 — 1280 — 1000V 348 464 464 700 — — — Rated power (P) in kilowatts 220/230V 161 181 209 260 — 430 — 240V 176 200 228 280 — 450 — 380/400V 280 315 355 450 — 750 — 415V 307 346 394 490 — 770 — 440V 326 367 418 520 — 830 — 500V 370 417 474 590 — 940 — 660/690V 494 556 633 780 — 1300 — 1000V 509 678 678 1000 — — — AC-6A Operation Transformer Loads Values are application specific. Calculation is I AC-3 = X / 6 * Ie Transformer where X is the inrush current e � of the transformer and Ie Transformer is the nominal current. AC-6B Operation Capacitor Loads Individual compensation rated operational current I of three-phase capacitors in amperes e Up to 525V 463 463 463 463 — — — 690V 265 265 265 265 — — — Maximum inrush current peak (x I ) 30 30 30 30 — — — e Component Lifesaving (Operations) 100,000 100,000 100,000 100,000 — — — Maximum Operating Frequency (ops/hr) 200 200 200 200 — — — � Up to 690V. � At maximum permissible ambient temperature. � Example — The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-84 XT IEC Power Control March 2009 Contactors and Starters Table 34-121. AC Ratings — 4-Pole Description XTCF020B XTCF032C XTCF045C XTCF063D XTCF080D XTCF125G XTCF160G XTCF200G AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50-60 Hz Open (Amps) at 40°C (I ) 22 32 45 3 80 125 160 200 th at 50°C (I ) 21 30 41 60 76 116 150 188 th at 60°C (I ) 20 28 39 54 69 108 138 172 th 34 Enclosed (Amps) 18 27 36 50 64 100 128 160 Conventional Free Air Thermal Current, 1-Pole Open (Amps) 60 84 117 162 207 325 415 516 Enclosed (Amps) 54 76 105 146 186 292 373 464 AC-3 Operation Rated Operational Current, 50/60 Hz (I ) in amperes e 220/230V 12 18 25 40 50 80 95 115 240V 12 18 25 40 50 80 95 115 380/400V 12 18 25 40 50 80 95 115 415V 12 18 25 40 50 80 95 115 440V 12 18 25 40 50 80 95 115 500V 10 18 25 40 50 80 95 115 660/690V 7 12 15 25 32 65 80 93 Rated Power, (P) in kilowatts 220/230V 3.5 5 7.5 2.5 15.5 25 30 37 240V 4 5.5 8.5 13.5 17 27.5 33 40 380/400V 5.5 7.5 11 18.5 22 37 45 55 415V 7 10 14.5 24 30 48 57 70 440V 7.5 10.5 15.5 25 32 51 60 75 500V 7 12 17.5 28 36 58 70 85 660/690V 6.5 11 14 23 30 63 75 90 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-85 XT IEC Power Control March 2009 Contactors and Starters DC Ratings Table 34-122. DC Ratings — DC-1 Description XTCE007B XTCE009B XTCE012B, XTCE015B XTCE018C XTCE025C XTCE032C XTCF020B Rated operation current {1} (Ie) in amperes 60V 20 20 20 20 35 40 40 110V 20 20 20 20 35 40 40 34 220V 15 15 15 15 35 40 40 440V 1 1.3 1.3 1.3 2.9 2.9 2.9 XTCE040D XTCE050D XTCE065D XTCE080F XTCE095F XTCE115G XTCE150G 60V 50 60 72 110 110 160 160 110V 50 50 72 110 110 160 160 220V 45 45 65 70 70 90 90 440V 2.9 2.9 2.9 4.5 4.5 4.5 4.5 XTCE185L XTCE225L XTCE250L XTCE300M XTCE400M XTCE500M XTCE580N 60V 300 300 300 400 400 400 — 110V 300 300 300 400 400 400 — 220V 300 300 300 400 400 400 — 440V 11 11 11 11 11 11 — XTCE650N XTCE750N XTCE820N XTCEC10N XTCEC14P XTCEC20R XTCEC16R 60V — — — — — — — 110V — — — — — — — 220V — — — — — — — 440V — — — — — — — Table 34-123. DC Ratings — DC-3 Description XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C Rated operation current {1} (I ) in amperes e 60V 20 20 20 20 35 35 40 110V 20 20 20 20 35 35 40 220V 1.5 1.5 1.5 1.5 10 10 25 440V 0.2 0.2 0.2 0.2 0.6 0.6 0.6 XTCE040D XTCE050D XTCE065D XTCE080F XTCE095F XTCE115G XTCE150G 60V 50 60 72 110 110 160 160 110V 50 50 72 110 110 160 160 220V 25 25 35 35 35 40 40 440V 0.6 0.6 0.6 1 1 1 1 XTCE185L XTCE225L XTCE250L XTCE300M XTCE400M XTCE500M XTCE580N 60V 300 300 300 400 400 400 — 110V 300 300 300 400 400 400 — 220V 300 300 300 400 400 400 — 440V — — — — — — — XTCE650N XTCE750N XTCE820N XTCEC10N XTCEC14P XTCEC20R XTCEC16R 60V — — — — — — — 110V — — — — — — — 220V — — — — — — — 440V — — — — — — — CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-86 XT IEC Power Control March 2009 Contactors and Starters Table 34-124. DC Ratings — DC-5 Description XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C Rated operation current {1} (I ) in amperes e 60V 20 20 20 20 35 35 40 110V 20 20 20 20 35 35 40 220V 1.5 1.5 1.5 1.5 10 10 25 440V 0.2 0.2 0.2 0.2 0.6 0.6 0.6 34 XTCE040D XTCE050D XTCE065D XTCE080F XTCE095F XTCE115G XTCE150G 60V 50 60 72 110 110 160 160 110V 50 50 72 110 110 160 160 220V 25 25 35 35 35 40 40 440V 0.6 0.6 0.6 1 1 1 1 XTCE185L XTCE225L XTCE250L XTCE300M XTCE400M XTCE500M XTCE580N 60V 300 300 300 400 400 400 — 110V 300 300 300 400 400 400 — 220V 300 300 300 400 400 400 — 440V — — — — — — — XTCE650N XTCE750N XTCE820N XTCEC10N XTCEC14P XTCEC20R — 60V — — — — — — — 110V — — — — — — — 220V — — — — — — — 440V — — — — — — — Table 34-125. DC Ratings — 4-Pole Description XTCF020B XTCF032C XTCF045C XTCF063D XTCF080D XTCF125G XTCF160G XTCF200G Rated operational current, open (I ) in amperes e DC-1 Operation 60V 22 32 45 63 80 125 160 200 110V 22 32 45 63 80 125 160 200 220V 6 32 45 63 80 125 160 200 440V 1.3 3 3 5 5 100 125 150 DC-3 Operation 60V 20 32 45 63 80 125 160 200 110V 20 32 45 63 80 125 160 200 220V 1.5 32 45 63 80 125 160 200 440V 0.2 6 6 8 8 75 95 115 DC-5 Operation 60V 20 32 45 63 80 125 160 200 110V 20 25 32 50 80 125 160 200 220V 1.5 15 22 38 70 100 125 150 440V 0.2 4 4 8 8 60 75 90 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-87 XT IEC Power Control March 2009 Contactors and Starters Heat Loss Table 34-126. Current Heat Loss (3-Pole) in Watts Description XTCE007B XTCE009B XTCE012B, XTCF020B XTCE015B XTCE018C XTCE025C XTCE032C Current heat loss (3-Pole) in watts at I 3 3 3 3 7.3 9.6 12.1 th at I to AC-3/400V 0.37 0.6 1.1 1.8 1.9 3.8 6.1 e Impedance per pole, mΩ 2.5 2.5 2.5 2.5 2 2 2 34 XTCE040D XTCE050D XTCE065D XTCE072D XTCE080F XTCE095F XTCE115G XTCE150G XTCE170G Current heat loss (3-Pole) in watts at I 11.3 19 28.8 28.8 12.2 18.2 20.3 30.7 41.1 th at I to AC-3/400V 7.2 11.3 19 23 9.6 13.5 15.9 27.0 34.7 e Impedance per pole, mΩ 1.5 1.5 1.5 1.5 0.5 0.5 0.4 0.4 0.4 XTCE185L XTCE225L XTCE250L XTCE300M XTCE400M XTCE500M XTCE580N Current heat loss (3-Pole) in watts at I 34 45 55 37 58 113 61 th at I to AC-3/400V 16 23 28 21 37 58 32 e Impedance per pole, mΩ — — — — — — — XTCE650N XTCE750N XTCE820N XTCEC10N XTCEC14P XTCEC20R XTCEC16R Current heat loss (3-Pole) in watts at I 69 78 96 96 188 192 155 th at I to AC-3/400V 41 54 65 96 — — 123 e Impedance per pole, mΩ — — — — — — — Table 34-127. Current Heat Loss (4-Pole) in Watts Description XTCF020B XTCF032C XTCF045C XTCF063D XTCF080D XTCF125G XTCF160G XTCF200G Current Heat Loss (3-Pole) at I in watts 4.7 8.2 12 16 23 29 46 60 th Impedence per pole, mΩ 2.5 2 1.5 1 0.7 0.6 0.6 0.5 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-88 XT IEC Power Control March 2009 Contactors and Starters Life Curves kW A AC-3/400 V 900 1600 XTCEC16R XTCEC10N 560 1000 AC-3/400V A k k kW 450 820 XTCE820N 90 170 XTCE170G 400 75 150 XTCE150G 355 650 XTCE650N 55 115 34 XTCE115G 315 580 95 45 XTCE095F 250 37 500 XTCE500M XTCE065D 200 400 30 XTCE300M 160 300 22 40 18.5 XTCE040D XTCE032C 132 XTCE250L 15 250 110 XTCE225L 225 11 25 XTCE025C 90 185 XTCE185L XTCE018C 7.5 18 XTCE015B 75 145 5.5 12 XTCE012B 55 104 4 9 XTCE009B, XTMC9A 3 7 XTCE007B 45 85 5 37 72 4 XTMC9A 30 58 3 XT TMC9A 2 22 43 18.5 36 15 30 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1 2 4 6 10 Component Lifespan (millions of operations) 11 23 7.5 16 0.01 0.02 0.04 6 0.1 0.2 0.4 0.6 1 2 3 4 5 6 8 10 Component Lifespan (millions of operations) XTCE007B – XTCE170G XTCE185L – XTCEC16R Figure 34-39. Normal Switching Duty AC-4/400 V kW A 750 1280 XTCEC16R R 450 800 XTCEC10N N 355 656 XTCE820N N kW A AC-4/400V XTCE750N N 315 576 512 280 XTCE650N N 250 XTCE150G, 200 360 XTCE500M M 52 XTCE170G 160 296 XTCE400M M 47 XTCE115G 41 132 240 XTCE300M M 33 6 XTCE080F 110 200 XTCE250L L 90 164 XTCE225L L 19 75 140 XTCE185L L XTCE050D 17 15 55 104 45 85 9 37 72 XTCE025C 7.5 30 58 5.5 22 43 4 9 18.5 36 XTCE009B 3.5 15 30 2.5 6.5 XTCE007B 5 11 23 4 7.5 16 3 XT TMC9A 5.5 12 2 4 8.8 3 6.5 2.2 5 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1 2 4 6 10 1.5 3.5 Component Lifespan (millions of operations) 0.01 0.02 0.03 0.04 0.06 0.1 0.2 0.3 0.4 0.6 1 2 3 4 5 6 8 10 Component Lifespan (millions of operations) XTCE007B – XTCE170G XTCE185L – XTCEC16R Figure 34-40. Extreme Switching Duty For more information visit: www.eaton.com CA08102001E Rated Output of Three-phase Motors 50 – 60 Hz Rated Output of Three-phase Motors 50 – 60 Hz – 60 Hz Rated Operational Current III 50 – 60 Hz e e Rated Output of Three-phase Motors 50 – 60 Hz Rated Output of Three-phase Motors 50 – 60 Hz Rated Operational Current Ie 50 – 60 Hz Rated Operational Current III 50 – 60 Hz e IEC Contactors & Starters 34-89 XT IEC Power Control March 2009 Contactors and Starters AC-1/400 V Operating characteristics: XTCF200G 200 Non-inductive and slightly inductive loads Electrical characteristics: Switch on: 1 x Rated current 34 Switch off: 1 x Rated current 160 XTCF160G Utilization category: 100% AC-1 Typical applications: Electrical heating XTCF125G 125 80 XTCF080D 63 XTCF063D 45 XTCF045C 32 XTCF032C 22 XTCF020B 0.1 0.2 0.4 0.6 1 2 4 6 10 Component Lifespan (millions of operations) Figure 34-41. Switching Duty for Non-motor Loads, 4-Pole — XTCF020B – XTCF200G AC-1/400 V A 700 600 XTCE065D 500 XTCE050D 450 XTCE040D 400 350 XTCE032C 300 XTCE025C 250 XTCE018C C 200 150 XTCE012B,, 120 XTCE015B 100 XTCE007B, 90 XTCE009B 70 50 40 30 20 15 3 5 7 20 30 50 0 300 500 900 Seconds 2 10 70 100 700 Duration of load 1min 3 min 5 min 10 min 15 min Figure 34-42. Short-time Loading, 3-Pole — XTCE007B – XTCE065D CA08102001E For more information visit: www.eaton.com Breaking Current A Short-time Current XTCE007B, XTCE009B, XTCE012B, XTCE015B X XTCE015 5 5B XTCEC20R 0R R IEC Contactors & Starters 34-90 XT IEC Power Control March 2009 Contactors and Starters 2000 XTCEC20R A AC-1/400 V XTCEC16R 1800 19000 XTCEC16R X R AC-1/400 V 1400 XTCEC14P XTCE XTCE750N 0N 900 XTCE580N 800 10000 XTCE820N N N N N XTCEC10N, XTCEC14P XTCEC10N, XTCEC14P XTCE400M 8000 XTCE650N X N N 500 XTCE300M XTCE580N X N N 6000 XTCE500M X M M 5000 XTCE400M M M 34 4000 160 XTCE150G, XTCE170G E1 XTCE300M M M 130 3000 XTCE250L X 110 XTCE080F XTCE080F 2500 80 2000 65 XTCE185L, XTCE225L E 1800 XTCE115G, 1500 XTCE150G, XTCE170G 1100 XTCE080F, XTCE095F 0 1000 20 XTMC9A 700 10 500 7 5 400 4 300 3 2 200 1 0.1 0.2 0.3 0.5 0.7 1 2 3 5 7 10 2 3 5 7 10 20 30 50 70 100 200 300 500 700 900 Seconds Component Lifespan (millions of operations) Duration of load 1 min 3 min 5 min 10 min n 15 min Figure 34-43. Switching Duty for Non-motor Loads, 3-Pole — Figure 34-44. Short-Time Loading, 3-Pole — XTCE080F – XTCEC16R XTCE007B – XTCEC20R Ops./h Ops./h 6000 4000 3000 � � � 4000 � 2000 � � � 1500 � 2000 1000 800 600 � 1000 500 � 400 800 � 300 600 200 400 � 150 100 200 50 0 10 20 30 40 50 60 70 8090 100 % 100 P [kW/hp] N 0 10 20 30 40 50 60 70 8090 100 % � Utilization Category P [kW/hp] N Type Characteristic Curve Above � Utilization Category AC-1 AC-3 AC-4 Type Characteristic Curve Above XTCE185L 2 1 6 AC-1 AC-3 AC-2 XTCE225L 2 1 6 AC-4 XTCE250L 2 1 6 XTCE007B – XTCE015B 3 1 5 XTCE300M 3 2 7 7 XTCE400M 3 2 XTCE018C – XTCE032C 3 2 5 XTCE500M 3 2 7 XTCE040D – XTCE065D 3 2 5 XTCE580N 3 4 5 XTCE080F – XTCE150G 3 4 5 XTCE650N 3 4 5 � XTCE750N 3 4 5 P = max. motor rating (kW/hp) of the relevant contactor. N XTCE820N 3 4 5 ops./h = max. number of operations per hour. � P = max. motor rating (kW/hp) of the relevant contactor. 7 to 150 hp N ops./h = max. number of operations per hour. 185 to 820 hp Figure 34-45. Maximum Operating Frequency — Related to Rating and Utilization Category (400V) For more information visit: www.eaton.com CA08102001E Breaking Current A Short-time Current IEC Contactors & Starters 34-91 XT IEC Power Control March 2009 Contactors and Starters Dimensions XTCE Contactors (3-Pole) 36 [1.42] 4 x M4 Dia. 34 68 60 [2.36] 18 [2.68] [.71] 45 [1.77] Auxiliary C 35 [1.38] Type 8.7 [.34] 3.2 [.13] Typ. XTCEXFAC_ 117 [4.61] 6.5 [.26] 5.1 [.20] XTCEXFCC_ 117 [4.61] 45 [1.77] 75 [2.95] XTCEXFATC_ 125 [4.92] C Figure 34-46. Frame B, XTCE007B and XTCE015B Contactors with Screw Terminals (7 – 15A) XTCF020B — Approximate Dimensions in mm [in] 68 26.4 [2.68] 4 x M4 Dia. [1.04] 52.3 [2.06] 60 [2.36] 1.8 3.2 [.13] [.07] 6.5 [.26] 1.8 35 [1.38] [.07] 8.7 [.34] 75 [2.95] Typ. 5.1 [.20] 125.2 [4.93] 45 [1.77] Figure 34-47. Frame B, XTCEC007B – XTCEC012B Contactors with Spring Cage Terminals (7 – 12A) — Approximate Dimensions in mm [in] 71 [2.80] 2 x M4 Dia. 38 [1.50] 85 [3.46] 60.4 [2.38] 75 [2.95] 4.5 [.17] 4.8 [.19] 4.5 [.17] 6.5 [.26] 17.7 [.70] 6.4 10.6 97.4 [3.83] 35 [1.38] [.25] [.42] 11.6 138.7 [5.46] [.46] 11.6 [.46] 45 [1.77] Note: Sideways distance to grounded parts: 6 mm [.39 in] Figure 34-48. Frame C, XTCE018C – XTCE032C Contactors (18 – 32A) — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-92 XT IEC Power Control March 2009 Contactors and Starters 4 x M4 Dia. 34 104 105 [4.13] 57 [4.09] [2.24] 86.4 [3.40] 45 [1.77] 4.7 [.19] 34.4 [1.35] 6.9 [.27] 55 [2.17] 113.8 [4.48] 132.1 [5.20] Note: Sideways distance to 146.8 [5.78] grounded parts: 6 mm [.39 in] Figure 34-49. Frame D, XTCE040D – XTCE072D Contactors (40 – 75A) — Approximate Dimensions in mm [in] 4 x M6 Dia. 70 [2.79] 90 [3.54] 82.5 [3.25] 111 [4.37] 85.5 [3.37] 142 [5.59] Note: Sideways distance to grounded parts: 10 mm [.39 in] 160 [6.30] Figure 34-50. Frame F – G, XTCE080F – XTCE170G Contactors (80 – 170A) — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E 57 [2.24] 76.5 [3.01] 170 [6.69] 156 [6.14] 156 [6.14] IEC Contactors & Starters 34-93 XT IEC Power Control March 2009 Contactors and Starters W1 W 11 [.43] Dia. M6 Dia. 34 H2 H1 H H3 W3 D1 W2 W4 140 [5.51] D 8 [.31] W W1W2W3W4H H1 H2 H3 D D1 Frame L 140 [5.51] 160 [6.30] 120 [4.72] 20 [.79] 48 [1.89] 180 [7.09] 164 [6.46] 189 [7.44] 160 [6.30] 208 [8.19] 5 [.20] (185 – 250A) Frame M 160 [6.30] 180 [7.09] 130 [5.12] 25 [.98]48 [1.89] 200 [7.87] 184 [7.24] 209 [8.23] 180 [7.09] 216 [8.50] 6 [.24] (300A – 400A) Frame M 160 [6.30] 180 [7.09] 130 [5.12] 38 [1.50] 57 [2.24] 200 [7.87] 189 [7.44] 219 [8.62] 180 [7.09] 216 [8.50] 6 [.24] (500A – 580A) Figure 34-51. Frame L – M, XTCE185L – XTCE570M Contactors (185 – 580A) — Approximate Dimensions in mm [in] A Dia. M6 Dia. 232 256 215 H [9.13] [10.08] [8.46] 165 [6.50] 80 W D1 [3.15] 140 [5.51] 250 [9.84] 232 [9.13] 270 [10.63] W H D1 A (Dia.) XTCE580N 45 [1.77] 296 [11.65] 6 [.24] 13.5 [.53] XTCE650N 45 [1.77] 296 [11.65] 6 [.24] 13.5 [.53] XTCE750N 45 [1.77] 296 [11.65] 6 [.24] 13.5 [.53] XTCE820N 45 [1.77] 296 [11.65] 6 [.24] 13.5 [.53] XTCEC10N 45 [1.77] 296 [11.65] 10 [.40] 13.5 [.53] Figure 34-52. Frame N, XTCE580N – XTCEC10N Contactors (580 – 1000A) — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-94 XT IEC Power Control March 2009 Contactors and Starters M6 Dia. 210 342 [8.27] [13.46] 232 256 215 34 [9.13] [10.08] [8.46] 308 [12.13] 165 [6.50] 10 14 [.55] 60 130 [5.12] [.39] Dia. [2.36] 100 100 232 [9.13] [3.94] [3.94] 260 [10.24] Figure 34-53. Frame P, XTCEC14P Contactor (1400A, AC-1) — Approximate Dimensions in mm [in] 210 392 [8.27] [15.43] 300 272 [11.81] 10.71] 352 [13.86] 150 [5.91] 10 [.39] 252 [9.92] 40 40 14 [.55] [1.57] [1.57] Dia. 80 [3.15] 80 [3.15] 150 [5.90] 125 [4.92] 172.5 [6.79] 172.5 [6.79] 515 [20.28] M6 Dia. 270 [10.63] 430 [16.93] Figure 34-54. Frame R, XTCEC16R, XTCEC20R Contactors — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-95 XT IEC Power Control March 2009 Contactors and Starters XTCF Contactors (4-Pole) 2xM4 45.0 60.0 18.0 [1.77] [2.36] [0.71] 34 68.0 [2.68] 6.5 [0.26] 36.0 3.2 35.0 [1.42] [0.13] [1.38] 75.0 [2.95] 45.0 [1.77] 117.0 [4.61] Figure 34-55. Frame B, XTCF020B Contactors — Approximate Dimensions in mm [in] 85.0 2xM4 [3.35] 60.0 75.0 38.0 [2.95] [1.50] 71.0 [2.80] 6.5 35.0 58.0 [0.26] 4.5 [1.38] [2.28] [0.18] 97.4 [3.83] 138.0 [5.43] Figure 34-56. Frame C, XTCF032C – XTCF045C Contactors — Approximate Dimensions in mm [in] 2xM4 115.0 86.4 [4.53] [3.40] 105.0 57.0 104.0 [4.13] [2.24] [4.09] 6.9 45.0 74.0 [0.27] 4.7 [1.77] [2.91] [0.19] 114.0 85.0 [4.49] [3.35] 132.1 [5.20] 147.0 [5.79] Figure 34-57. Frame D, XTCF063D – XTCF080D Contactors — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-96 XT IEC Power Control March 2009 Contactors and Starters 4 x M6 170.0 [6.69] 57.0 156.0 156.0 [2.24] [6.14] 34 [6.14] 122.0 [4.80] 82.5 70.0 [3.25] 133.0 [2.76] [5.24] 85.5 [3.37] 142.0 [5.59] 160.0 [6.30] 175.0 [6.89] Figure 34-58. Frame G, XTCF125G – XTCF200G Contactors — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-97 XT IEC Power Control March 2009 Contactors and Starters XTAE Starters with XTOB Overload Relay Mounting 60 146 Mounting 45.3 117.1 Holes for [2.36] [5.75] Holes for [1.78] [4.61] M4 or #8 M4 or #8 Screws 45 132.5 Screws 75.8 35 (4 Places) [1.77] [5.22] (4 Places) [2.98] [1.38] 34 60 [2.36] 105 117.8 [4.13] [4.64] 174 [6.85] 83.3 [3.28] 88.4 [3.48] To Reset Figure 34-59. Frame B, XTAE007B – XTAE012B Starters with XTOB 98 [3.86] (7 – 12A) — Approximate Dimensions in mm [in.] To Reset 93.6 [3.69] 139.8 45 Mounting Figure 34-61. Frame D, XTAE040D – XTAE065D Starters with XTOB [5.50] [1.77] Holes for (40 – 65A) — Approximate Dimensions in mm [in.] M4 or #8 97.8 35 Screws [3.85] [1.38] (2 Places) 75 [2.95] 136.4 [5.37] 100.2 [3.94] 105.3 [4.15] To Reset Figure 34-60. Frame C, XTAE018C – XTAE032C Starters with XTOB (18 – 32A) — Approximate Dimensions in mm [in.] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-98 XT IEC Power Control March 2009 Contactors and Starters 90 [3.54] 160 [6.30] 70 [2.76] 150 [5.91] 34 156 57 170 [6.14] [2.24] [6.69] 277 [10.91] 91 [3.58] 74 [2.91] 95 [3.74] 7 [.276] 100 [3.94] Dia. 118 [4.65] 134 [5.28] Figure 34-62. Frame F – G, XTAE080F – XTAE150G Starters with XTOB (80 – 150A) — Approximate Dimensions in mm [in.] 150 [5.91] 110 [4.33] 523 328 [20.60] [12.91] 34 [1.34] ~144 [5.67] Figure 34-63. Frame L, XTAE185L – XTAE250L Starters with XTOB (185 – 250A) — Approximate Dimensions in mm [in.] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-99 XT IEC Power Control March 2009 Contactors and Starters XTAE Starters with C396 Overload Relay 45.3 Mounting 117.0 Mounting [1.78] Holes for [4.61] 70.0 Holes for 175.0 M4 or #8 [2.76] M6 or #10 [6.89] 75.8 35 Screws Screws 160.0 [2.98] [1.38] (4 Places) (4 Places) [6.30] 34 60 [2.36] 91.8 [3.61] 126.4 [4.98] 156.0 Press [6.14] To Reset 2.3 [.09] 240.5 [9.47] 6.2 88.1 [.24] [3.47] Press 32.3 [1.27] To Reset 2.3 [.09] Figure 34-64. Frame B, XTAE007B – XTAE012B Starters with C396 (0.1 – 15A) — Approximate Dimensions in mm [in.] 18.8 108.0 Mounting 45.1 139.6 [.74] [4.25] Holes for [1.78] [5.50] M4 or #8 90.0 97.5 35 Screws [3.54] [3.84] [1.38] (2 Places) 111.8 [4.40] 75.0 Figure 34-67. Frame F and G, XTAE080F – XTAE115G Starters with C396 [2.95] 108.8 (22 – 110A) — Approximate Dimensions in mm [in.] [4.28] 146.9 [5.78] Press Mounting To Reset 70.0 Holes for 175.0 2.3 [.09] [2.76] M6 or #10 [6.89] Screws 160.0 (4 Places) [6.30] 5.9 88.1 [.23] [3.47] Figure 34-65. Frame C, XTAE018C – XTAE032C Starters with C396 (0.1 – 32A) — Approximate Dimensions in mm [in.] Mounting 146.1 Holes for [5.75] 339.5 291.3 M4 or #8 [13.37] 132.5 45 [11.47] Screws [5.22] [1.77] (4 Places) Press 364.8 To Reset [14.36] 2.3 [.09] 105.0 [4.13] 152.6 202.1 [6.01] [7.95] Press To Reset 45.1 2.3 [.09] [1.78] 33.4 149.7 [1.31] [5.89] 11.4 105.7 [.45] [4.16] 98.0 [3.86] 65.0 [2.56] 128.0 [5.04] Figure 34-66. Frame D, XTAE040D – XTAE065D Starters with C396 (15 – 75A) — Approximate Dimensions in mm [in.] Figure 34-68. Frame G, XTAE115G – XTAE150G Starters with C396 (30 – 150A) — Approximate Dimensions in mm [in.] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-100 XT IEC Power Control March 2009 Contactors and Starters Reversing Combination 34 H W D Frame B (7 – 15A) Frame C (18 – 32A) Frame D (40 – 65A) W HDW HDW HD 90 68 117 90 85 138 110 115 146.8 [3.54] [2.68] [4.61] [3.54] [3.34] [5.43] [4.33] [4.53] [5.78] Figure 34-69. XTCR Reversing Combination Frame B – D — Approximate Dimensions in mm [in] 299 314 [11.77] [12.36] 176 [6.93] M 6 196 [7.72] 183 [7.20] Figure 34-70. XTCR Reversing Combination Frame F – G — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-101 XT IEC Power Control March 2009 Contactors and Starters Star-Delta Combination H 34 W D Frame B Frame C Frame D W HDW HDW HD 158 68 117 158 85 138 188 115 146.8 [6.22] [2.68] [4.61] [6.22] [3.34] [5.43] [7.40] [4.53] [5.78] Figure 34-71. Star-Delta Combination Frame B – D — Approximate Dimensions in mm [in] 299 314 [11.77] [12.36] 144 [5.67] 144 [5.67] M 6 308 [12.13] 183 [7.20] Figure 34-72. Star-Delta Combination Frame F – G — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-102 XT IEC Power Control March 2009 Contactors and Starters Mechanical Interlock Contactor with Terminal Shroud 15 W [.59] 34 H Figure 34-73. Frame L – M. XTCEXMLM Mechanical Interlock — Approximate Dimensions in mm [in] 20 515 [20.28] [.79] 430 [16.93] XTCE185L, XTCE300M, XTCE500M, XTCE580N, XTCE225L, XTCE400M XTCE570M XTCE650N, 270 XTCE250L XTCE750N, [10.63] XTCE820N, 300 XTCEC10N [11.81] WH WH WH WH 150 384 150 404 174 426 236 506 [5.91] [15.12] [5.91] [15.91] [6.85] [16.77] [9.29] [19.92] 9 [.35] Figure 34-74. XTCEXMLN — Approximate Dimensions in mm [in] Figure 34-75. Frame L – N Contactors, XTCE185L – XTCEC10N, with Terminal Shroud XTLEXTS — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-103 XT IEC Power Control March 2009 Contactors and Starters Suppressor Flat Strip Conductor Terminals 34 D W2 W1 W1 W2 H1 H2 H3 D XTCEXRSB... 25 9.2 25.9 28 32 9 XTCEXVSB... [.98] [.36] [1.02] [1.10] [1.26] [.35] W XTCEXVSLB... XTCEXDSB... XTCEXRSC... 25 9.2 16 28 32 9 WH XTCEXVSC... [.98] [.36] [.63] [1.10] [1.26] [.35] XTCEXVSLC... XTCE500M – XTCE570M 171 [6.73] 232 [9.13] XTCEXRSF... 25 20 18.5 28 32 9 XTCE750N – XTCE820N 231 [9.09] 310 [12.20] XTCEXVSF... [.98] [.79] [.73] [1.10] [1.26] [.35] XTCEXVSLF... Figure 34-76. Suppressor — Approximate Dimensions in mm [in] Figure 34-78. XTCEXTFB — Approximate Dimensions in mm [in] Cable Terminal Block Three-Phase Commoning Link H W 12.5 [.49] 135 222 30 [5.31] [8.74] W [1.18] XTCEXCLK3B 112 [4.41] H XTCEXCLK4B 157 [6.18] XTCE185L – XTCE250L 198 [7.80] XTCBXCLK5B 202 [7.95] XTCE300M – XTCE400M 218 [8.58] Figure 34-79. Frame B Three-Phase Commoning Link — Approximate Dimensions in mm [in] Figure 34-77. XTCEXTLA — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com H1 H2 H3 13.1 [.52] 18.1 [.71] H IEC Contactors & Starters 34-104 XT IEC Power Control March 2009 Overload Relays — XTOB, XTOT Contents Description Page Overload Relays — XTOB, XTOT Catalog Number Selection . . . . . . . . . . . . . . . 34-104 Product Selection . . . . . . . . . 34-105 34 Accessories . . . . . . . . . . . . . . 34-106 Technical Data and Specifications . . . . . . . . . . . 34-108 Dimensions . . . . . . . . . . . . . . 34-110 Reference Data . . . . . . . . . . . . 34-210 XTOB Overload Relay XTOT Overload Relay Catalog Number Selection Table 34-128. XT IEC Overload Relays — Catalog Numbering System X T O B P 1 6 B C 1 S Designation Mounting XT = XT Line of IEC Control BLANK Direct to Contactor = S = Separate Mount Type OB = Bimetallic Overload Relay Trip Class OT = Current Transformer Overload Relay C1 = Class 10A C3 = Class 30 Overload Release Frame B Frame G Frame Size P16 = 0.1 – 0.16A 035 = 25 – 35A Designation P24 = 0.16 – 0.24A 050 = 35 – 50A P40 = 0.24 – 0.4A 070 = 50 – 70A B = 45 mm P60 = 0.4 – 0.6A 100 = 70 – 100A C = 45 mm 001 = 0.6 – 1A 125 = 95 – 125A 1P6 = 1.0 – 1.6A 150 = 120 – 150A D = 55 mm 2P4 = 1.6 – 2.4A 175 = 145 – 175A 004 = 2.4 – 4A G = 90 mm Frame L 006 = 4 – 6A L = 140 mm 010 = 6 – 10A 070 = 50 – 70A 012 = 9 – 12A 100 = 70 – 100A BLANK = XTOT Only 016 = 12 – 16A 125 = 95 – 125A 160 = 120 – 160A Frame C 220 = 160 – 220A P16 = 0.1 – 0.16A 250 = 200 – 250A P24 = 0.16 – 0.24A Frame M P40 = 0.24 – 0.4A P60 = 0.4 – 0.6A 063 = 42 – 63A 001 = 0.6 – 1A 090 = 60 – 90A 1P6 = 1.0 – 1.6A 125 = 85 – 125A 2P4 = 1.6 – 2.4A 160 = 110 – 160A 004 = 2.4 – 4A 240 = 160 – 240A 006 = 4 – 6A 290 = 190 – 290A 010 = 6 – 10A 400 = 270 – 400A 016 = 10 – 16A 540 = 360 – 540A 024 = 16 – 24A Frame N 032 = 24 – 32A 063 = 42 – 63A Frame D 090 = 60 – 90A 010 = 6 – 10A 125 = 85 – 125A 016 = 10 – 16A 160 = 110 – 160A 024 = 16 – 24A 240 = 160 – 240A 040 = 24 – 40A 290 = 190 – 290A 057 = 40 – 57A 400 = 270 – 400A 065 = 50 – 65A 540 = 360 – 540A 075 = 65 – 75A 630 = 420 – 630A Frame F 035 = 25 – 35A 050 = 35 – 50A 070 = 50 – 70A 100 = 70 – 100A For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-105 XT IEC Power Control March 2009 Overload Relays — XTOB, XTOT Product Selection Table 34-129. Overload Relay Overload Contact Contact For Use Short-Circuit Protection (A) Catalog Price Releases, I Sequence Configu- with Number U.S. $ r Fuse Maximum CEC/NEC ration Contactor Circuit Fuse Type 1 Type 2 Amp Range Breaker Coordination, Coordination, gG/gL gG/gL 34 Frame B — Direct Mount 0.1 – 0.16 1NO-1NC 7 – 15A 25 0.5 25 3 XTOBP16BC1 97 95 0.16 – 0.24 1NO-1NC 7 – 15A 25 1 25 3 XTOBP24BC1 0.24 – 0.4 1NO-1NC 7 – 15A 25 2 25 3 XTOBP40BC1 0.4 – 0.6 1NO-1NC 7 – 15A 25 4 25 3 XTOBP60BC1 24698 96A2 14/ 0.6 – 1 22 1NO-1NC 7 – 15A 25 4 25 3 XTOB001BC1 1 – 1.6 1NO-1NC 7 – 15A 25 6 25 6 XTOB1P6BC1 1.6 – 2.4 1NO-1NC 7 – 15A 25 10 25 6 XTOB2P4BC1 2.4 – 4 1NO-1NC 7 – 15A 25 16 25 15 XTOB004BC1 4 – 6 1NO-1NC 7 – 15A 25 20 25 20 XTOB006BC1 6 – 10 1NO-1NC 7 – 15A 50 25 25 35 XTOB010BC1 9 – 12 1NO-1NC 9 – 15A 50 25 25 45 XTOB012BC1 XTOB016BC1 12 – 16 1NO-1NC 12 – 15A 50 25 30 45 Frame C — Direct Mount 0.1 – 0.16 1NO-1NC 18 – 32A 25 0.5 25 3 XTOBP16CC1 97 95 0.16 – 0.24 1NO-1NC 18 – 32A 25 1 25 3 XTOBP24CC1 0.24 – 0.4 1NO-1NC 18 – 32A 25 2 25 3 XTOBP40CC1 0.4 – 0.6 1NO-1NC 18 – 32A 25 4 25 3 XTOBP60CC1 246989614/ 0.6 – 1 1NO-1NC 18 – 32A 25 4 25 3 XTOB001CC1 22 1 – 1.6 1NO-1NC 18 – 32A 25 6 25 6 XTOB1P6CC1 1.6 – 2.4 1NO-1NC 18 – 32A 25 10 25 6 XTOB2P4CC1 2.4 – 4 1NO-1NC 18 – 32A 25 16 25 15 XTOB004CC1 4 – 6 1NO-1NC 18 – 32A 25 20 25 20 XTOB006CC1 25 25 25 XTOB010CC1 6 – 10 1NO-1NC 18 – 32A 50 10 – 16 1NO-1NC 18 – 32A 63 35 30 25 XTOB016CC1 35 30 25 XTOB024CC1 16 – 24 1NO-1NC 18 – 32A 100 24 – 32 1NO-1NC 25 – 32A 125 63 30 25 XTOB032CC1 Frame D — Direct Mount 6 – 10 1NO-1NC 40 – 72A 50 25 25 25 XTOB010DC1 97 95 10 – 16 1NO-1NC 40 – 72A 63 35 25 25 XTOB016DC1 16 – 24 1NO-1NC 40 – 72A 63 50 30 25 XTOB024DC1 24 – 40 1NO-1NC 40 – 72A 125 63 125 125 XTOB040DC1 24698 96 40 – 57 1NO-1NC 50 – 72A 160 80 150 150 XTOB057DC1 50 – 65 1NO-1NC 65 – 72A 160 100 150 200 XTOB065DC1 65 – 75 1NO-1NC 72A 200 125 150 200 XTOB075DC1 Frame F – G — Direct Mount 25 – 35 1NO-1NC 80 – 170A 125 100 125 125 XTOB035GC1 97 95 35 – 50 1NO-1NC 80 – 170A 160 125 150 200 XTOB050GC1 50 – 70 1NO-1NC 80 – 170A 250 160 150 200 XTOB070GC1 70 – 100 1NO-1NC 80 – 170A 315 200 400 400 XTOB100GC1 24698 96 95 – 125 1NO-1NC 80 – 170A 315 250 500 400 XTOB125GC1 120 – 150 1NO-1NC 80 – 170A 315 250 600 600 XTOB150GC1 145 – 175 1NO-1NC 150 – 170A 315 250 600 600 XTOB175GC1 Frame F – G — Separate Mount 25 – 35 1NO-1NC 80 – 170A 125 100 125 125 XTOB035GC1S 97 95 35 – 50 1NO-1NC 80 – 170A 160 125 150 200 XTOB050GC1S 50 – 70 1NO-1NC 80 – 170A 250 160 150 200 XTOB070GC1S 70 – 100 1NO-1NC 80 – 170A 315 200 400 400 XTOB100GC1S 24698 96 95 – 125 1NO-1NC 80 – 170A 315 250 500 400 XTOB125GC1S 120 – 150 1NO-1NC 80 – 170A 315 250 600 600 XTOB150GC1S 145 – 175 1NO-1NC 150 – 170A 315 250 600 600 XTOB175GC1S Frame L 50 – 70 1NO-1NC 185 – 250A 250 160 150 200 XTOB070LC1 13 59795 70 – 100 1NO-1NC 185 – 250A 315 200 400 400 XTOB100LC1 95 – 125 1NO-1NC 185 – 250A 315 250 500 400 XTOB125LC1 120 – 160 1NO-1NC 185 – 250A 400 250 600 600 XTOB160LC1 24 698 96 � � 160 – 220 1NO-1NC 185 – 250A 400 315 800 800 XTOB220LC1 � � 200 – 250 1NO-1NC 225 – 250A 400 315 600 700 XTOB250LC1 � For separate mounting, short circuit Type 1 rating is 500A and short circuit Type 2 rating is 400A. Notes: Suitable for protection of EEx e-motors. EC pro- totype test certificate available upon request. Short circuit protection: Observe the maxi- mum permissible fuse of the contactor with Observe manuals MN03402001E and direct device mounting. See MN03402001E MN03407001E, see Table 34-134. for more information on overload relays for Technical Data . . . . . . . . . . . . . . . . . . Page 34-108 Frame B – G. Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-110 Trip Class: 10A Discount Symbol . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-106 XT IEC Power Control March 2009 Overload Relays — XTOB, XTOT � Table 34-130. Current Transformer Operated Overload Relays Overload Contact Contact For Use Short-Circuit Protection (A) Catalog Price Releases, I Sequence Configu- with Number U.S. $ r Type 1 Type 2 Circuit CEC/NEC ration Contactor Coordination, Coordination, Breaker Fuse Amp Range gG/gL gG/gL Frame M – N — Separate Mount 42 – 63 1NO-1NC 300 – 500A — — 150 200 XTOT063C3S 97 95 60 – 90 1NO-1NC 300 – 500A — — 250 250 XTOT090C3S 34 85 – 125 1NO-1NC 300 – 500A — — 500 400 XTOT125C3S 110 – 160 1NO-1NC 300 – 500A — — 600 600 XTOT160C3S 98 96 160 – 240 1NO-1NC 300 – 500A — — 600 700 XTOT240C3S 190 – 290 1NO-1NC 300 – 500A — — 600 700 XTOT290C3S 270 – 400 1NO1-NC 300 – 500A — — 1000 1000 XTOT400C3S 360 – 540 1NO-1NC 500A — — 600 1000 XTOT540C3S 420 – 630 1NO-1NC 630A — — 600 1000 XTOT630C3S � The main current parameters are defined by the main current wiring which is used. Accessories � Table 34-131. DIN Rail or Panel Mount Adapter, Frame C – D For Use Pkg. Catalog Price with… Qty. Number U.S. $ XTOB…CC1 5 XTOBXDINC XTOB…DC1 2 XTOBXDIND � Can be snap fitted on a top hat rail (DIN rail) to IEC/EN 60715 or can be screw fitted. Table 34-132. Terminal Shroud For Use Catalog Price with… Number U.S. $ XTOB…LC1 XTOBXTSL For direct mounting of … Catalog Price Number U.S. $ XTOB…LC1 to XTCE185L, XTOBXTSCL XTCE225L or XTCE250L Table 34-133. Terminal Lug Kit — Set of (3) Lugs Description For Use Pkg. Catalog Price with… Qty. Number U.S. $ Set of 3 Lugs XTOB…LC1 1 XTOBXTLL #6 AWG-350MCM Table 34-134. Documentation — Manuals for Overload Monitoring of EEX e-motors Publication For Use Number with… MN03402001E XTOB…BC1 XTOB…CC1 MN03407001E XTOB…DC1 XTOB…GC1 Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-110 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-107 XT IEC Power Control March 2009 Overload Relays — XTOB, XTOT 34 Frame B Frame C Frame D Frame F – G Frame L (7 – 15A) (18 – 32A) (40 – 72A) (80 – 170A) (185 – 250A) Figure 34-80. Overload Fitted Directly to the Contactor Frame F – G Frame L (80 – 170A) (185 – 250A) Frame C Frame D (18 – 32A) (40 – 72A) Figure 34-81. Overload Mounted Separately from the Contactor CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-108 XT IEC Power Control March 2009 Overload Relays — XTOB, XTOT Technical Data and Specifications Table 34-135. XTOB Overload Relay — Technical Data and Specifications Description XTOB…BC1, XTOB…CC1 XTOB…DC1 XTOB…GC1, XTOB…GC1S XTOB...LC1 General Standards IEC/EN 60947, VDE 0660, UL, CSA Climate Proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30 � 34 Ambient Temperature -25°C to +55°C -25°C to +55°C -25°C to +55°C -25°C to +50°C [-13°F to 131°F] [-13°F to 131°F] [-13°F to 131°F] [-13°F to 22°F] Temperature Compensation Continuous Continuous Continuous Continuous Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-Sinusoidal Shock 10 mS 10g 10g 10g 10g Degree of Protection IP20 IP20 IP20 P00 Protection Against Direct Contact when Actuated from Finger and back of hand Finger and back of Finger and back of hand With terminal cover Front (IEC 536) proof hand proof proof XTOBXTS...L Insulation Voltage (Ui) V AC 690 690 690 1000 Overvoltage Category / Pollution Degree III/3 III/3 III/3 III/3 Impulse Withstand Voltage (Uimp) V AC 6000 6000 6000 8000 Operational Voltage (Ue) V AC 690 690 690 1000 Safe Isolation to VDE 0106 Part 101 and part 101/A1 Between auxiliary contacts and main contacts (V AC) 440 440 440 440 Between main contacts (V AC) 440 440 440 440 Overload Release Setting Range 0.1 – 32A 6 – 75A 25 – 150A 50 – 250A Short Circuit Protection Maximum Fuse See Table 34-129 on Page 34-105. Temperature Compensation Residual Error > 40°C <0.25 <0.25 <0.25 <0.25 Current Heat Loss (3 Conductors) Lower value of setting range, W 2.5 3 16 16 Upper value of setting range 6 7.5 28 28 Terminal Capacity 2 Solid, mm 2 x (1 – 6) 2 x (1 – 16) 2 x (4 – 16) — 2 Flexible with ferrule, mm 2 x (1 – 4) 1 x 25 1 x (4 – 70) — � � 2 x (1 – 6) 2 x (1 – 10) 2 x (4 – 50) — 2 Flexible with cable lug, mm — — — 95 2 Stranded with cable lug, mm — — — 120 Solid or Stranded, AWG 14 - 8 14 - 2 2 / 0 250MCM Flat Conductor (number of segments x width x — — — 6 x 16 x 18 2 thickness, mm Busbar — Width (mm) — — — 20 x 3 Terminal Screw M4 M6 M10 M8 x 25 Tightening Torque Nm 1.8 3.5 10 24 Lb-in 16 31 88.5 221.3 Tools Pozidriv screwdriver Size 2 Size 2 — — Standard screwdriver 1 x 6 1 x 6 — — Hexagon socket head spanner (SW) — — 5 mm 13 mm Auxiliary and Control Circuit Connections Impulse Withstand Voltage (Uimp) V AC 6000 6000 6000 6000 Overvoltage Category/Pollution Degree III/3 III/3 III/3 III/3 Terminal Capacity 2 Solid, mm 2 x (0.75 – 4) 2 x (0.75 – 4) 2 x (0.75 – 4) 2 x (0.75 – 4) 2 Flexible with ferrule, mm 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) 2 x (0.75 – 2.5) Solid or Stranded (AWG) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) 2 x (18 – 12) Terminal Screw M3.5 M3.5 M3.5 M3.5 Tightening Torque Nm 0.8 – 1.2 0.8 – 1.2 0.8 – 1.2 0.8 – 1.2 Lb-in 7 – 10.6 7 – 10.6 7 – 10.6 7 – 10.6 Tools Pozidriv screwdriver Size 2 Size 2 Size 2 Size 2 Standard screwdriver 1 x 6 1 x 6 1 x 6 1 x 6 Rated Insulated Voltage (Ui) V AC 500 500 500 500 Rated Operational Voltage 500 500 500 500 Safe Isolation to VDE 0106 Part 101 and part 101/A1 Between auxiliary contacts 240 240 240 240 Conventional Thermal Current, I 66 6 — th � Ambient Temperature Operating Range to IEC/EN 60947, PTB: -5°C to +50°C. � 2 6 mm flexible with ferrules to DIN 46228. � Main contact terminal capacity, solid and stranded conductors with ferrules: When using 2 conductors use identical cross-section. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-109 XT IEC Power Control March 2009 Overload Relays — XTOB, XTOT Table 34-135. XTOB Overload Relay — Technical Data and Specifications (Continued) Description XTOB…BC1, XTOB…CC1 XTOB…DC1 XTOB…GC1, XTOB…GC1S XTOB...LC1 Auxiliary and Control Circuit Connections (Continued) Rated Operational Current — AC-15 Make Contact 120V 1.5 1.5 1.5 1.5 240V 1.5 1.5 1.5 1.5 415V 0.5 0.5 0.5 0.5 34 500V 0.5 0.5 0.5 0.5 Break Contact 120V 1.5 1.5 1.5 1.5 240V 1.5 1.5 1.5 1.5 415V 0.9 0.9 0.9 0.9 500V 0.8 0.8 0.8 0.8 Rated Operational Current — � DC-13 L/R ≤ 15 mS 24V 0.9 0.9 0.9 0.9 60V 0.75 0.75 0.75 0.75 110V 0.4 0.4 0.4 0.4 220V 0.2 0.2 0.2 0.2 Short Circuit Rating without Welding Maximum Fuse, A gG/gl 6 6 6 6 � Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated. Tripping Characteristics These tripping characteristics are the mean values of the spread at 20°C ambient temperature in a cold state. Tripping time depends on response current. With devices at operating temperature, the tripping time of the overload relay reduces to approximately 25% of the read off value. Specific characteristics for each individual setting range can be found in MN03402001E. 2h 2h 2h 100 100 100 XTOB...GC1 XTOB...LC1 XTOB...BC1, 60 XTOB...CC1, 60 60 40 XTOB...DC1 40 40 20 20 20 10 10 10 6 6 6 4 4 4 2 2 2 1 1 1 40 40 40 3-Phase 3-Phase 3-Phase 20 20 20 10 10 10 6 6 6 4 4 4 2-Phase 2-Phase 2-Phase 2 2 2 1 1 1 0.6 0.6 0.6 1 1.5 2 3 4 6 8 10 15 20 1 1.5 2 3 4 6 8 10 15 20 1 1.5 2 3 4 6 8 10 15 20 x Setting Current x Setting Current x Setting Current Figure 34-82. Tripping Characteristics Instructional Leaflets Table 34-136. Instructional Leaflets Publication Description Number Pub51221 XTOB, D Frame Overload Relays (Inside of Packaging) Pub51222 XTOB, B – C Frame Overload Relays (Inside of Packaging) CA08102001E For more information visit: www.eaton.com Minutes Seconds Minutes Seconds Seconds Minutes IEC Contactors & Starters 34-110 XT IEC Power Control March 2009 Overload Relays — XTOB, XTOT Dimensions 35.5 34 [1.40] 29.5 48 [1.16] 39.5 [1.89] [1.56] 65 [2.56] 45 [1.77] 83 [3.27] Figure 34-83. Frame B – C, XTOB…BC1 and XTOB…CC1 Overload Relays — Approximate Dimensions in mm [in] 20.3 51.5 [.80] [2.03] 79.2 [3.12] 95.5 [3.76] 60 [2.36] 102 [4.02] Figure 34-84. Frame D, XTOB…DC1 Overload Relay — Approximate Dimensions in mm [in] D1 42.5 [1.67] H 5 [.20] D2 16.5 [.65] D W HW D D1 D2 XTOB…CC1 85 [3.46] 45 [1.77] 90.5 [3.56] 58.3 [2.30] 3.8 [.15] XTOB…DC1 86 [3.39] 60 [2.36] 112 [4.41] 80.5 [3.17] 4.7 [.19] Figure 34-85. Frame B – C, XTOBXDINC DIN Rail or Panel Mount Adapter and Frame D, XTOBXDIND DIN Rail or Panel Mount Adapter — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-111 XT IEC Power Control March 2009 Overload Relays — XTOB, XTOT 99 [3.90] 80 [3.15] 73 [2.87] 34 138 [5.43] 74 [2.91] 95 [3.74] 63 [2.48] 100 [3.94] 129 [5.08] 118 [4.65] 134 [5.28] Figure 34-86. Frame F – G, XTOB…GC1 Overload Relay — Approximate Dimensions in mm [in] 100 [3.94] 121 [4.76] 74 [2.91] 95 [3.74] 63 [2.48] 99 [3.90] 129 [5.08] 118 [4.65] 134 [5.28] Figure 34-87. Frame F – G, XTOB…G1CS Overload Relay — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-112 XT IEC Power Control March 2009 Overload Relays — XTOB, XTOT 110 [4.33] 121 [4.76] 144 [5.67] 96 [3.78] 111 [4.37] 48 [1.89] 34 144 [5.67] 74 94 [2.91] [3.70] 169 [6.65] 7 [.28] * 5 7 [.28] Dia. [.20] 25 ** 16.5 [.98] * = OFF [.65] ** = RESET/ON 128 [5.04] 11 [.43] Dia. Figure 34-88. Frame L, XTOB…LC1 Overload Relay — Approximate Dimensions in mm [in] Current Transformer Operated Overload Relay 185 [7.28] 185 [7.28] 1.5 [.06] 4.3 [.17] 7.5 [.30] 8 [.31] 44 21 [.83] [1.73] * M4 85 26 [1.02] 71 33 55 44 [1.73] [3.35] 55 [2.80] [1.30] [2.17] * [2.17] 26 159 [6.26] [1.02] 172 – 250 [6.77 – 9.84] * = RESET/ON 200 [7.87] 65 65 [2.56] [2.56] 71 [2.80] 90° 90° 90° 27 [1.06] Figure 34-89. XTOT…C3S — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E * ** IEC Contactors & Starters 34-113 XT IEC Power Control March 2009 Overload Relays — C396 Contents Product Description Standards and Certifications The C396 is a self-powered, robust Description Page ■ UL Listed Components: Stand- electronic overload designed for inte- alone, starter-mounted devices and Overload Relays — C396 grated use with Freedom NEMA, XT remote reset kit. Catalog Number IEC, and DP contactors. The overload ■ CSA Certified Components: Stand- Selection . . . . . . . . . . . . . . . . 34-113 can be ordered as a stand-alone alone, starter-mounted devices and version that is designed for Panel- Product Selection . . . . . . . . . . 34-114 remote reset kit. 34 Mounting and for use on 35 mm DIN Accessories . . . . . . . . . . . . . . . 34-115 ■ IEC EN 60947-4-1, EN 60947-5-1 rail. The C396 has an FLA range of Technical Data and ■ CE 0.1 – 150 Amps with internal CTs, and Specifications . . . . . . . . . . . . 34-116 up to 1500 Amps using external CTs. ■ RoHS Dimensions . . . . . . . . . . . . . . . 34-117 Reference Data . . . . . . . . . . . . 34-210 Features ■ Standard Version: Selectable trip class (5, 10, 20, 30) with Selectable Manual or Auto Reset ■ Broad 5:1 FLA range ■ Self-Powered Design, will accept AC voltages from 12 – 690V 50/60 Hz ■ Ambient Temperature Compensation ■ Low Heat Generation ■ Phase Loss Protection ■ Phase Unbalance Protection ■ Electrically isolated 1NO-1NC Contacts (Push-to-Test) C396 Electronic ■ Trip Status Indicator Overload Relay ■ FLA range of 0.1 – 1500 Amps Catalog Number Selection Table 34-137. C396 Electronic Overload Relays — Catalog Numbering System C 3 9 6 A 2 A P 0 5 S E L A X Device Type Stand-Alone Overload Relay Suffix C396 = C396 Electronic Overload Relay AX = All Frame Sizes XT IEC Adapter Suffix Frame Size Frame B Frame D A = 45 mm XB = 0.1 – 0.5A XD = 6.4 – 32A B = 65 mm 9 – 45A 0.4 – 2.0A 15 – 75A C = 110 mm 1 – 5A 1.6 – 8A Frame F – G 6.4 – 32A XF = 22 – 110A Feature Set Frame C Reset Type XC = 0.1 – 0.5A 0.4 – 2.0A 2 = Standard A = Auto 1 – 5A Max. Amperes 1.6 – 8A Current Rating 6.4 – 32A Frame A (45 mm) P05 = 0.1 – 0.5 Class 002 = 0.4 – 2.0 005 = 1 – 5 SEL = Selectable 008 = 1.6 – 8 032 = 6.4 – 32 045 = 9 – 45 Frame B (65 mm) 075 = 15 – 75 110 = 22 – 110 Frame C (110 mm) 150 = 30 – 150 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-114 XT IEC Power Control March 2009 Overload Relays — C396 Product Selection 34 Frame C XT Starter with Cat. No. C396C3A150SELAX C396 Electronic Overload with C396CBARXT Table 34-138. C396 Stand-Alone Overload Relay Table 34-140. C396 Overload for Integrated Use with XT IEC Contactors FLA Range Description Catalog Price FLA Range XT IEC Contactor Catalog Price (Amps) Frame Size / Width Number U.S. $ (Amps) Number U.S. $ � 45 mm Overload Frame Size 45 mm Overload Frame Size 0.1 – 0.5 B / 45 mm C396A2AP05SELXB 0.1 – 0.5 — C396A2AP05SELAX 0.4 – 2.0 B / 45 mm C396A2A002SELXB 0.4 – 2.0 C396A2A002SELAX 1 – 5 B / 45 mm C396A2A005SELXB 1 – 5 C396A2A005SELAX 1.6 – 8 B / 45 mm C396A2A008SELXB 1.6 – 8 C396A2A008SELAX 6.4 – 32 B / 45 mm C396A2A032SELXB 6.4 – 32 C396A2A032SELAX 9 – 45 C396A2A045SELAX 0.1 – 0.5 C / 45 mm C396A2AP05SELXC � 0.4 – 2.0 C / 45 mm C396A2A002SELXC 65 mm Overload Frame Size 1 – 5 C / 45 mm C396A2A005SELXC 15 – 75 — C396B2A075SELAX 1.6 – 8 C / 45 mm C396A2A008SELXC 22 – 110 C396B2A110SELAX 6.4 – 32 C / 45 mm C396A2A032SELXC � 110 mm Overload Frame Size 6.4 – 32 D / 55 mm C396A2A032SELXD 30 – 150 — C396C2A150SELAX 9 – 45 D / 55 mm C396A2A045SELXD � Overload comes with a panel/DIN rail mounting adapter assembled. 65 mm Overload Frame Size No separate mounting adapter accessory offered. 15 – 75 D / 55 mm C396B2A075SELXD � Panel mount only! Overload comes with integrated pass-through 22 – 110 F – G / 90 mm C396B2A110SELXF holes for power wires. Bus Bar Kit (C396CBAR or C396CBARXT, see 110 mm Overload Frame Size — Stand-Alone or Direct to XT Contactor Table 34-141) and Lug Kit (C396CLUG) must be purchased separately with Indicated Kit if customer refers not to use pass-through capability. � 30 – 150 G / 90 mm C396C2A150SELAX 110 mm XT Bus Bar Kit C396CBARXT Table 34-139. Current Transformer Kits for Use with Stand-Alone � � Overload Relay C396A2A005SELAX Catalog Number shown is for Stand-Alone C396 Overload Relay. For direct connection to XT Frame G contactor, order additional XT Bus FLA Range Description Catalog Price Bar Kit, C396CBARXT, shown in Tables 34-140 and 34-141. If load side (Amps) Number U.S. $ lugs are required, order C396CLUG (set of 3). 60 – 300 300: 5 Panel-mount CT Kit C396CTK300 with integrated, pass-through holes. Kit includes CT, bus bars, lugs and hardware to mount C396A2A005SELAX(not included). 120 – 600 600: 5 Panel-mount CT Kit C396CTK600 with integrated, pass-through holes. Kit includes CT, bus bars, lugs andhardware to mount C396A2A005SELAX (not included). 200 – 1000 1000: 5 Panel-mount CT Kit C396CTK1000 with integrated, pass-through holes. Kit includes CT, bus bars, lugs and hardware to mount C396A2A005SELAX (not included). 300 – 1500 1500: 5 Panel-mount CT Kit C396CTK1500 with integrated, pass-through holes. Kit includes CT, bus bars, lugs and hardware to mount C396A2A005SELAX (not included). � C396A2A005SELAX is not included in the current transformer kits. This item must be ordered separately. Technical Data . . . . . . . . . . . Page 34-116 Dimensions . . . . . . . . . . . . . . Pages 34-117, 34-118 Accessories . . . . . . . . . . . . . Page 34-49 Discount Symbol . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-115 XT IEC Power Control March 2009 Overload Relays — C396 Accessories Table 34-141. C396 Electronic Overload Accessories Description Catalog Price Number U.S. $ � Reset Bar Kit C396ARST assembles to the top of the overload to 34 increase reset area. �� 110 mm Lug Kit C396CLUG 110 mm Bus Bar Kit C396CBAR �� 110 mm XT Bus Bar C396CBARXT �� Kit Remote Reset C396RR024DC �� 24V DC Remote Reset C396RR024AC �� 24V AC Remote Reset C396RR120AC �� 120V AC Remote Reset C396RR240AC C396ARST + �� 240V AC C396RR _ _ _ _ _ Assembled to a C396 Overload Relay Mechanical Reset with E22 Flush Push- button and Mechani- �� cal Push Rod Plastic Black Bezel E22PB6N29L Chrome Bezel E22P6N29L Mechanical Push E22MRL Rod — for external �� mechanical reset Mounting Hole E22ARK �� Adapter Kit � Discount Symbol 1CD7. � Discount Symbol 1CD1. � Set of 3 lugs and hardware, 2 sets are required to wire line and load sides. Bus Bar Kit (C396CBAR or C396CBARXT) is needed to use the Lug Kit. � Bus bar kits do not include lugs. Order C396CLUG if lugs are needed (3 lugs per kit). � The operator button is blue with the letters “RESET” printed in white. The push rod is 4.72" long and can be cut to the desired length. This kit can be used alone or in conjunction with the C396 Reset Bar Kit, C396ARST, to increase the size of the reset area on the overload. � Reset Bar Kit (C396ARST) required to use the Remote Reset modules. Note that all Freedom Starters come with Reset Bars. � Must be cut to proper length — uncut 4.72 inches (119.9 mm) long. � Enables a 22.5 mm operator to be mounted in a 30.5 mm holes — Technical Data . . . . . . . . . . . . Page 34-116 1/16 to 7/32 inch (1.6 to 5.6 mm) panel thickness. Dimensions . . . . . . . . . . . . . . Pages 34-117, 34-118 Discount Symbol . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-116 XT IEC Power Control March 2009 Overload Relays — C396 Technical Data and Specifications Table 34-142. Overload Relay Specifications Overload Relay Specifications (Continued) General C396_2_ General Description C396_2_ Description Standard Standard Protection Climate Considerations Thermal 1.05 x FLA: Does not trip Ambient Temperature -25° to 65°C (-13° to 149°F) inside enclosure 34 1.25 x FLA: Overload trip (Operating) Phase Loss 1 Phase = 0, Trip time = 3s (Hot Status) Ambient Temperature -40° to 80°C (-40° to 176°F) (Storage / Transportation) Phase Imbalance Max - Min / Max > 40%, Trip time = 3s (Hot Status) Humidity UL991 (H3): 20 – 95% non-condensing Inrush Current > 8 x Max FLA, Trip time is 0.3s (Cold Status) Altitude (Operating) NEMA ICS1: 2000 meters max above sea level Trip Class Pollution (Operating — Pollution degree 3 Class 5, 10, 20, 30 Selectable External) Reset Mechanical Shock 15g Resistance M / M-O Manual / Manual + Stop (IEC/EN 68-2-17) A / A-O Auto / Auto + Stop Auto Reset Time = 165s Vibration (Lloyd’s Register 6g of Shipping, Vibration Test Indications 2) Test Indicator Yellow Temperature Continuous Trip Indicator Yellow Compensation PCBA Voltages Power Sensing 3 phase Control Voltage 12 – 690V AC, 50/60 Hz Instant Reset by Power ON CPU reset by Power ON after 2 – 3s Insulation Voltage (Ui) — 1000V AC Main Circuit Thermal memory < 3 min. Insulation Voltage (Ui) — 690V AC Cold and Hot Trip Curves Power ON > 20 min. is Hot Status Control Circuit Power Consumption < 300 mW Impulse Withstand Voltage 6000 Options (Uimp) VAC Safety Cover Covers FLA dial, DIP switches FLA Range Remote Reset 24V DC, 24V AC, 120V AC, 240V AC 45 mm Frame: C396A_ 0.1 – 45A 65 mm Frame: C396B_ 15 – 110A 110 mm Frame: C396C_ 30 – 150A Safety Degree of Protection IP20 (Stand-Alone Version Only) Capacity Control Terminal Capacity 18 – 14 AWG Control Terminal Tightening 0.79 (7) Torque in Nm (lb-in) Load Terminal Capacity 45 mm Frame: C396A_ 14 – 6 AWG 65 mm Frame: C396B_ 10 – 1 AWG 110 mm Frame: C396C_ 6 AWG – 250 mcm Load Terminal Tightening Torque in Nm (lb-in) 45 mm Frame: C396A_ 3.2 (28) 65 mm Frame: C396B_ 9.0 (80) 110 mm Frame: C396C_ 22.6 (200) Dimensions . . . . . . . . . . . . . . Pages 34-117, 34-118 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-117 XT IEC Power Control March 2009 Overload Relays — C396 Dimensions Mounting Holes for #6 or M4 Screws 91.5 (2 Qty.) [3.60] 34 82.0 59.5 [3.23] [2.34] 39.1 [1.54] 4.5 23.8 5.0 [.18] [.94] [.20] 40.0 86.5 49.0 [1.57] [3.41] [1.93] Figure 34-90. 45 mm Stand-Alone C396 Electronic Overload Relay — Approximate Dimensions in mm [in] Mounting Holes for #10 or M5 Screws (4 Qty.) .8 41.9 114.0 4.1 [.03] [1.65] [4.49] [.16] 6.1 [.24] 63.5 [2.50] 108.7 119.9 [4.28] [4.72] .8 [.03] 1.5 65.0 [.06] [2.56] 40.4 [1.59] Figure 34-91. 65 mm Stand-Alone C396 Electronic Overload Relay — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-118 XT IEC Power Control March 2009 Overload Relays — C396 96.5 154.9 31.9 [3.80] [6.10] [1.25] Mounting Holes for #10 or M5 Screws (4 Qty.) 47.9 [1.89] 6.4 1.0 34 [.25] [.04] 1.5 [.06] 94.0 94.0 217.0 [3.70] [3.70] [8.54] 3.0 [.12] 4.0 [.16] 96.5 153.7 110.0 [3.80] [6.05] [4.33] Figure 34-92. 110 mm Stand-Alone C396 Electronic Overload Relay — Approximate Dimensions in mm [in] 8.4 8.4 [.33] [.33] 8.7 8.7 [.34] 14.0 [.34] 14.0 [.55] [.55] 2.0 3.0 [.08] [.12] 77.3 77.8 69.5 69.5 [3.04] [3.06] [2.74] [2.74] 45.0 82.4 45.0 82.4 [1.77] [3.24] [1.77] [3.24] Figure 34-93. 45 mm C396 (0.1 – 8A) Direct Connect to XT Frame B Figure 34-94. 45 mm C396 (6.4 – 32A) Direct Connect to XT Frame B Contactor — Approximate Dimensions in mm [in] Contactor — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-119 XT IEC Power Control March 2009 Overload Relays — C396 12.1 12.5 14.6 15.0 14.0 [.48] [.49] [.57] [.59] 18.0 [.55] [.71] 2.0 3.0 [.08] [.12] 34 78.7 83.8 69.5 [3.10] [3.30] 73.8 70.0 [2.74] [2.91] [2.76] 45.0 82.4 45.0 80.0 [1.77] [3.24] [1.77] [3.15] Figure 34-95. 45 mm C396 (0.1 – 8A) Direct Connect to XT Frame C Figure 34-97. 45 mm C396 (6.4 – 45A) Direct Connect to XT Frame D Contactor — Approximate Dimensions in mm [in] Contactor — Approximate Dimensions in mm [in] 17.6 12.1 12.5 17.6 [.69] [.48] [.49] 14.0 [.69] 55.6 3.0 [.55] 3.0 [2.19] [.12] 7.0 [.12] [.28] 106.0 [4.17] 79.2 69.5 [3.12] [2.74] 96.0 [3.78] 45.0 82.4 [1.77] [3.24] 65.0 106.0 [2.56] [4.17] Figure 34-96. 45 mm C396 (6.4 – 32A) Direct Connect to XT Frame C Contactor — Approximate Dimensions in mm [in] Figure 34-98. 65 mm C396 (15 – 75A) Direct Connect to XT Frame D Contactor — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-120 XT IEC Power Control March 2009 Overload Relays — C396 73.8 [2.91] 13.8 74.3 3.0 [.54] [2.93] [.12] 34 103.4 [4.07] 65.0 108.0 [2.56] [4.25] Figure 34-99. 65 mm C396 (22 – 110A) Direct Connect to XT Frame F – G Contactor — Approximate Dimensions in mm [in] 110.0 [4.33] 98.0 [3.86] 29.9 [1.18] 29.9 77.8 4.0 [1.18] [3.06] [.16] 201.0 [7.91] 226.3 93.0 [8.91] [3.66] 49.0 49.0 [1.93] [1.93] 128.0 151.7 [5.04] [5.97] Figure 34-100. 110 mm C396 (30 – 150A) + C396CBARXT Direct Connect to XT Frame G Contactor — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-121 XT IEC Power Control March 2009 Manual Motor Protectors Contents Manual Motor Protectors Protection in Different Controller Types The XTPB and XTPR MMPs are UL Listed Description Page under UL 508 as Manual Motor Protec- A UL 508 Type E Self-protected Manual Catalog Number tors. They provide an economical solu- Combination Starter/Motor Controller Selection . . . . . . . . . . . . . . . . 34-124 tion for applications requiring simple consists of a single device having inte- manual starting and stopping of motors. Product Selection . . . . . . . . . . 34-125 gral short circuit protection, a main set When used as an MMP, they are typically of contacts, motor overload protection, Accessories . . . . . . . . . . . . . . . 34-130 installed in an enclosure. Many enclo- 34 and may also include a UL listed Line Technical Data and sures are offered as accessories for the Side Adapter (see Figure 34-102). This Specifications . . . . . . . . . . . . 34-142 MMPs. Separate short-circuit protective type of controller is a legitimate short devices, such as circuit breakers or Dimensions . . . . . . . . . . . . . . . 34-150 circuit protective device and discon- fuses, are wired ahead of the MMPs. The nect means for the downstream motor. Reference Data . . . . . . . . . . . . 34-210 short-circuit protective device should be It does require an upstream feeder sized per the NEC code and should not Pushbutton short circuit protective device, but exceed 400% of the maximum FLA dial does not require a dedicated branch setting of the MMP. circuit protection or a disconnect means. A UL 508 Type E rating means Group Motor Installations that the unit clears a fault and does not A Group Motor Installation can be experience any welding of the power poles. A UL 508 Type E self-protected defined as more than one motor circuit protected by a single set of fuses or cir- manual combination starter will remain fully functional should a short cuit breaker on a motor branch circuit. This eliminates the need for individual circuit within its ratings occur. B-Frame fuses or circuit breakers for each A UL 508 Type F Self-protected Combi- Rotary motor circuit. Substantial component nation Motor Controller consists of a cost savings, panel space savings and UL 508 Listed Type E Self-protected reduced wiring installation time can be Manual Combination Starter/Motor achieved in Group Motor Installations. Controller, a UL Listed Contactor, and The MMPs are tested and listed for possibly a UL Listed Line Side Adapter. While the Type E self-protected manual group installation. If remote operation is required, a magnetic contactor can motor controller of this combination motor controller device is a legitimate be wired in series with the MMP. See B-Frame D-Frame Figure 34-101. short circuit protective device and disconnect means for the down- Article 430.53 of the National Electric stream motor, the contactor is not Code contains the rules and require- Product Description “self-protected.” E.g. XTCE007 – ments for Group Motor Installations. XTCE065. Eaton’s new XT family of Manual Refer to Application Note AP03402001E In addition, as a complete assembly or Motor Protectors (MMPs) features a for NEC requirement for group motor pushbutton or rotary ON/OFF manual installation. modular components, the device should disconnect, Class 10 adjustable have Type 2 Coordination certification. bimetallic overload relay and fixed Type 2 Coordination means the Starter or To Supply magnetic short circuit trip capability in the Controller must exhibit little or no dam- one compact unit. Two frame sizes age following a major short circuit fault Disconnect are available: Frame B (45 mm) for and should be able to be returned to proper motors with FLA ratings up to 32A service without replacing any parts. Or Circuit and Frame D (55 mm) covers motor Breaker FLA ratings up to 63A. Component in a Combination Fuses Motor Controller Application Description The XTPB and XTPR MMPs can also be The XTPB and XTPR MMPs can be wired in series with a magnetic contac- used in the following applications. Manual tor to complete the assembly of a XTPR XTPR XTPR Motor remotely operated, combination motor Motor Protective Circuit Breaker Protector controller. In many countries outside of the United States and Canada, especially Magnetic Contactor (Used for Europe, the MMPs are tested and Remote Control) classified as thermal magnetic circuit breakers for use in motor branch circuits. This can be an important Motors consideration for all companies who export their equipment and machines Figure 34-101. Group Motor Installation internationally. Both the XTPB and NEC 430-53 XTPR conform to IEC/EN 60947 and See Application Note — AP03402001E. have the CE Mark. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-122 XT IEC Power Control March 2009 Manual Motor Protectors Features Manual Motor Protectors ■ ON/OFF Rotary Handle with Lockout Self-Protected Manual Combination Starters Provision ■ Visible Trip Indication ■ Class 10 Overload Protection Group Installation UL 508 Type E Self-Protected Manual ■ Phase Loss Sensitivity Combination Starter Using the in-panel Main SCPD. 34 ■ Ambient Temperature Compensation Only Upstream Feeder SCPD required — to IEC/EN 60947, VDE 0660 no dedicated in-panel Main SCPD for MMP. ■ Fixed Short Circuit Trip — 14 times maximum setting of overload FLA Line Side Adapter (LSA) Line Side Adapter (LSA) dial Not required Required ■ Type 2 Coordination per IEC 947 ■ Identification Markers Standard on Starter Faceplate Line Side Adapter Line Side Adapter ■ Motor Applications from 0.1A to 63A XTPAXLSA XTPAXLSAD ■ Built-in heater and magnetic trip elements to protect the motor MMP MMP ■ Adjustment dial for setting motor FLA XTPR…BC1 XTPR…DC1 ■ DIN Rail Mount ■ Terminal Types Available: ❑ Screw terminals Line Side Adapter ❑ Screw (line) and Spring Cage (load) terminals Figure 34-102. Line Side Adapters — When to Use Them ❑ Spring Cage terminals Note: Line Side Adapters are not required for non-US applications. Most countries outside of the US classify the MMP as a thermal magnetic circuit breaker. ■ Accessories include: ❑ Front and Side Auxiliary Contacts Standards and Certifications ❑ Trip Indicating Contacts ❑ Tamperproof Cover for OLR Dial ■ UL Listed File No. E245398 Types (Configurations) ❑ Undervoltage Release ■ UL 508 Group Motor and Type E ■ Motor Protective Device with ❑ Shunt Trip Compliant Thermal and Magnetic Trip ❑ Thru-the-Door Operators ■ IEC/EN 60947 ❑ XTPB Pushbutton Actuated Manual ❑ Enclosures ■ CSA File 229767, Class 3211-05 Motor Protector up to 25A ❑ 3-Phase Line Side Connecting Links ■ DIN VDE 0660 Part 100, Part 101 and ❑ XTPR Rotary Actuated Manual Part 102 Motor Protector up to 63A ■ CCC ■ For the Protection of Transformers with a high inrush current: ❑ XTPT Manual Transformer Protector up to 25A — not UL Note: For Type 2 Coordination of MMCs, Approved see Tables 34-249 through 34-260 on Pages 34-210 through 34-215. ■ Motor Protective Device without Overload Function: ❑ XTPM Motor Protective Circuit Breaker up to 32A — not UL Approved For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-123 XT IEC Power Control March 2009 Manual Motor Protectors Table 34-143. Product Identification No. Description Page 1 Basic Units 1 XTPB Pushbutton Manual Motor 34-125 Protectors: 4 ■ Rated operational current up to 25A ■ Switching capacity 50 kA/415V ■ Short circuit release, fixed 34 setting to 14 x I u ■ Overload release, adjustable 0.6 — 1 x I u 2 ■ Single-phasing sensitive 2 XTPR Rotary Manual Motor 34-126 Protectors: ■ Rated operational current up to 32A, 65A ■ Switching capacity 150/50 kA/ 415V ■ Short circuit release, fixed setting to 14 x I u ■ Overload release, adjustable 5 5 0.6 — 1 x I u ■ Single-phasing sensitive 3 ■ With screws or spring-loaded terminals Mounting Accessories 3 Rotary Handle Mechanism: 34-133 ■ ON/OFF/Tripped switch position indication 5 ■ Lockable with 3 padlocks ■ Integrated door/cover interlock ■ Extendable by plug fit extension shaft ■ Handle latched in switch positions 2 ■ Optionally also without locking and door interlock 2 function 6 Insulated Enclosures: 34-138 ■ Surface mounting enclosures, IP40, IP55 and IP40 and IP55 front flush mounting enclosure Mounting/Wiring: 34-134 ■ Component adapter for busbar mounting ■ Three-phase commoning link for side-by-side mounting ■ Mounting kits for rapid mounting of direct-on-line, reversing and star-delta starters Add-On Functions 4 Voltage Releases: 34-132 ■ Undervoltage release ■ Shunt release ■ With screws or spring-loaded terminals 5 Standard Auxiliary Contacts: 34-130 ■ ON/OFF indication ■ Differential fault indication overload/short circuit release ■ ON/OFF for (high capacity) contact module ■ ON/OFF for starter combination ■ With early-make contacts ■ With screws or spring-loaded terminals 6 Current Limiter: 34-132 ■ Increases the switching capacity of the 10 – 25A Manual Motor Protectors to 100 kA/440V ■ Can be used for individual group protection CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-124 XT IEC Power Control March 2009 Manual Motor Protectors 34 XTPB XTPR, XTPM and XTPT XTPR B-Frame B-Frame D-Frame Catalog Number Selection Table 34-144. XT— Catalog Numbering System X T P R 0 1 2 B C 1 Designation Trip Class XT = XT IEC Power Control C1 = Class 10 Blank = Magnetic only (No thermal trip) Type Frame Size PB = Manual Motor Protector — Pushbutton PR = Manual Motor Protector — Rotary B = 45 mm D = 55 mm PM = Manual Motor Protector — Magnetic Only PT = Manual Transformer Protector (High Mag.) Current Ratings B Frame P16 = 0.16A 6P3 = 6.3A P25 = 0.25A 010 = 10A P40 = 0.40A 012 = 12A P63 = 0.63A 016 = 16A 001 = 1A 020 = 20A 1P6 = 1.6A 025 = 25A 2P5 = 2.5A 032 = 32A 004 = 4A D Frame 016 = 16A 050 = 50A 025 = 25A 058 = 58A 032 = 32A 063 = 63A 040 = 40A For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-125 XT IEC Power Control March 2009 Manual Motor Protectors Product Selection Product Selection for Manual Motor Starter Applications When ordering, specify Catalog Numbers For motors with service factors less For motor with service factor of 1.15 than 1.15, multiply the motor FLA by or greater, use motor nameplate Full according to the following stipulations: .90 to select appropriate MMP. Load Amperes to select the appropriate XT Manual Motor Protectors are MMP. selected based on the overload current 34 Example: For motor having FLA range required for a given motor. This of 6.4A and service factor of 1.0 Example: For motor having FLA of 11A current range is determined from the (6.4A x .90 = 5.76A) select Catalog and service factor of 1.15, select Cata- motor Full Load Ampere rating and Number XTPB6P3B01. log Number XTPR012BC1. Motor Service Factor usually found on See Application Note — AP03402001E. the motor nameplate. B-Frame Table 34-145. XTPB Pushbutton Manual Motor Protectors — Global and North American Ratings Type 1 and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip � Rated FLA Short Maximum Motor Ratings Screw Terminals Uninterrupted Adjustment Circuit Maximum kW Rating Maximum hp Rating — P (hp) Catalog Price Current — Range / Release — AC-3 — P (kW) UL 508/CSA C 22.2 No. 14 Number U.S. $ I = I (Amps) Overload I (Amps) u e rm 3-Phase 3-Phase Release — 220 – 380 – 440V 500V 660 – 200V 240V 480V 600V I (Amps) r 240V 415V 690V Frame B � � � � 0.16 0.1 – 0.16 2.2 — — — — 0.06 XTPBP16BC1 � � � � 0.25 0.16 – 0.25 3.5 — 0.06 0.06 0.06 0.12 XTPBP25BC1 � � � � 0.4 0.25 – 0.4 5.6 0.06 0.09 0.12 0.12 0.18 XTPBP40BC1 � � � � 0.63 0.4 – 0.63 8.8 0.09 0.12 0.18 0.25 0.25 XTPBP63BC1 � � 1 0.63 – 1 14 0.12 0.25 0.25 0.37 0.55 1/2 1/2 XTPB001BC1 � � 1.6 1 – 1.6 22 0.25 0.55 0.55 0.75 1.1 3/4 1 XTPB1P6BC1 2.5 1.6 – 2.5 35 0.37 0.75 1.1 1.1 1.5 1/2 1/2 1 1-1/2 XTPB2P5BC1 4 2.5 – 4 56 0.75 1.5 1.5 2.2 3 1 1 2 3 XTPB004BC1 6.3 4 – 6.3 88 1.1 2.2 3 3 4 1-1/2 1-1/2 3 5 XTPB6P3BC1 10 6.3 – 10 140 2.2 4 4 4 7.5 3 3 7-1/2 10 XTPB010BC1 12 8 – 12 168 3 5.5 5.5 5.5 11 3 3 7-1/2 10 XTPB012BC1 16 10 – 16 224 4 7.5 9 9 12.5 3 5 10 10 XTPB016BC1 20 16 – 20 280 5.5 9 11 12.5 15 5 5 10 15 XTPB020BC1 25 20 – 25 350 5.5 12.5 12.5 15 22 5 7-1/2 15 20 XTPB025BC1 � Select Manual Motor Protectors by full load amperes. Maximum Motor Ratings (kW, hp) are for reference only. � In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1). Notes: Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Can be snap-fit to IEC/EN 60715 top-hat (DIN) with 7.5 or 15 mm height. Service Factor (SF) — Setting I of current scale in dependence of load factor: r SF = 1.15 -> I = 1 x I r n mot SF = 1 -> I = 0.9 x I r n mot For manual motor protective circuit breaker switching capacity, see Page 34-147. Technical Data . . . . . . . . . . . . . . . . . . Page 34-142 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-126 XT IEC Power Control March 2009 Manual Motor Protectors 34 B-Frame D-Frame Table 34-146. XTPR Rotary Manual Motor Protectors with Screw Terminals — Global Ratings and North American Ratings Type 1 and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip � � Rated FLA Short Maximum Motor Ratings Screw Terminals Uninterrupted Adjustment Circuit Maximum kW Rating Maximum hp Rating — P (hp) Catalog Price Current — Range / Release — AC-3 — P (kW) UL 508/CSA C 22.2 No. 14 Number U.S. $ I = I (Amps) Overload I (Amps) u e rm 3-Phase 3-Phase Release — I (Amps) 220 – 380 – 440V 500V 660 – 200V 240V 480V 600V r 240V 415V 690V Frame B � � � � 0.16 0.1 – 0.16 2.2 — — XTPRP16BC1 — — 0.06 � � � � 0.25 0.16 – 0.25 3.5 — 0.06 XTPRP25BC1 0.06 0.06 0.12 � � � � 0.4 0.25 – 0.4 5.6 0.06 0.09 XTPRP40BC1 0.12 0.12 0.18 � � � � 0.63 0.4 – 0.63 8.8 0.09 0.12 XTPRP63BC1 0.18 0.25 0.25 � � 1 0.63 – 1 14 0.12 0.25 0.25 0.37 0.55 1/2 1/2 XTPR001BC1 � � 1.6 1 – 1.6 22 0.25 0.55 0.55 0.75 1.1 3/4 1 XTPR1P6BC1 2.5 1.6 – 2.5 35 0.37 0.75 1.1 1.1 1.5 1/2 1/2 1 1-1/2 XTPR2P5BC1 4 2.5 – 4 56 0.75 1.5 1.5 2.2 3 1 1 2 3 XTPR004BC1 6.3 4 – 6.3 88 1.1 2.2 3 3 4 1-1/2 1-1/2 3 5 XTPR6P3BC1 10 6.3 – 10 140 2.2 4 4 4 7.5 3 3 7-1/2 10 XTPR010BC1 12 8 – 12 168 3 5.5 5.5 5.5 11 3 3 7-1/2 10 XTPR012BC1 16 10 – 16 224 4 7.5 9 9 12.5 3 5 10 10 XTPR016BC1 20 16 – 20 280 5.5 9 11 12.5 15 5 5 10 15 XTPR020BC1 25 20 – 25 350 5.5 12.5 12.5 15 22 5 7-1/2 15 20 XTPR025BC1 32 25 – 32 448 7.5 15 15 22 30 7-1/2 10 25 30 XTPR032BC1 Frame D 16 10 – 16 224 4 7.5 9 9 12.5 3 5 10 15 XTPR016DC1 25 16 – 25 350 5.5 12.5 12.5 15 22 7-1/2 7-1/2 20 25 XTPR025DC1 32 25 – 32 448 7.5 15 17.5 22 22 10 10 25 30 XTPR032DC1 40 32 – 40 560 11 20 22 24 30 10 15 30 40 XTPR040DC1 50 40 – 50 700 14 25 30 30 45 10 15 30 40 XTPR050DC1 58 50 – 58 812 17 30 37 37 55 — — 40 — XTPR058DC1 65 55 – 65 882 18.5 34 37 45 55 — — — — XTPR063DC1 � Select Manual Motor Protectors by full load amperes. Maximum Motor Ratings (kW, hp) are for reference only. � In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1). � Catalog number shown comes with screw terminals. For Frame B devices up to 16A, spring cage terminals are available. For spring cage terminals on line and load sides, insert a “C” into the catalog number in the 5th position — Example: XTPRC_BC1. For spring cage terminals on the load side only, insert an “SC” into the catalog number in the 5th and 6th positions — Example: XTPRSC_BC1. Notes: Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Can be snap-fit to IEC/EN 60715 top-hat (DIN) with 7.5 or 15 mm height. Service Factor (SF) — Setting I of current scale in dependence of load factor: r SF = 1.15 -> I = 1 x I r n mot SF = 1 -> I = 0.9 x I r n mot For manual motor protective circuit breaker switching capacity, see Page 34-147. Technical Data . . . . . . . . . . . . . . . . . . Page 34-142 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-127 XT IEC Power Control March 2009 Manual Motor Protectors 34 B-Frame D-Frame � Table 34-147. XTPR Manual Self-Protected Motor Starters — North American Ratings, UL 508 Type E Motor Protective Device with Thermal and Magnetic Trip � Rated FLA Short Maximum Motor Ratings Rated Short-Circuit Line Side Price Manual Motor Price � Uninterrupted Adjustment Circuit Breaking Capacity (kA) Adapter U.S. $ Protector — U.S. $ Current — Range / Release — Screw Terminals Maximum hp Rating — P (hp) 240V 480/ 600/ I (Amps) Overload I (Amps) u rm 277V 347V 3-Phase Release — 200V 240V 480V/ 600V/ Catalog Catalog I (Amps) r 277V 247V Number Number Frame B � � 0.16 0.1 – 0.16 2.2 1/2 1/2 50 50 50 XTPAXLSA XTPRP16BC1 � � 0.25 0.16 – 0.25 3.4 1/2 1/2 50 50 50 XTPAXLSA XTPRP25BC1 � � 0.4 0.25 – 0.4 5.6 1/2 1/2 50 50 50 XTPAXLSA XTPRP40BC1 � � 0.63 0.4 – 0.63 8.8 1/2 1/2 50 50 50 XTPAXLSA XTPRP63BC1 � � 1 0.63 – 1 14 1/2 1/2 50 50 50 XTPAXLSA XTPR001BC1 � � 1.6 1 – 1.6 22 3/4 3/4 50 50 50 XTPAXLSA XTPR1P6BC1 2.5 1.6 – 2.5 35 1/2 1/2 1 1-1/2 50 50 50 XTPAXLSA XTPR2P5BC1 4 2.5 – 4 56 3/4 1 2 3 50 50 50 XTPAXLSA XTPR004BC1 6.3 4 – 6.3 88 1 1-1/2 3 5 50 50 50 XTPAXLSA XTPR6P3BC1 10 6.3 – 11 140 3 3 7-1/2 10 50 50 50 XTPAXLSA XTPR010BC1 12 8 – 12 168 3 3 7-1/2 — 42 42 — XTPAXLSA XTPR012BC1 16 10 – 16 224 3 5 10 — 42 42 — XTPAXLSA XTPR016BC1 20 16 – 20 280 5 5 — — 42 42 — XTPAXLSA XTPR020BC1 25 20 – 25 350 5 7-1/2 15 — 18 18 — XTPAXLSA XTPR025BC1 32 25 – 32 448 7-1/2 10 25 — 18 18 — XTPAXLSA XTPR032BC1 Frame D 16 10 – 16 224 3 5 10 10 50 50 50 XTPAXLSAD XTPR016DC1 25 16 – 25 350 7-1/2 7-1/2 20 25 50 50 50 XTPAXLSAD XTPR025DC1 32 25 – 32 448 10 10 25 30 50 50 50 XTPAXLSAD XTPR032DC1 40 32 – 40 560 10 10 30 40 50 50 50 XTPAXLSAD XTPR040DC1 50 40 – 50 700 10 15 30 — 65 65 — XTPAXLSAD XTPR050DC1 58 50 – 58 812 15 15 40 — 65 65 — XTPAXLSAD XTPR058DC1 65 55 – 65 882 15 15 40 — 65 65 — XTPAXLSAD XTPR063DC1 � UL 508 Type E starters are assembled from a standard XTPR and a special incoming terminal Line Side Adapter (XTPAXLSA or XTPAXLSAD). � Select Manual Motor Protectors by full load amperes. Maximum Motor Ratings (kW, hp) are for reference only. � In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1). Notes: A UL 508 Type E Self-Protected Manual Combination Starter (XTPR) consists of a Manual Motor Protector (XTPR) and a UL Listed Line Side Adapter (e.g. XTPAXLSA). The Type E Self-Protected Manual Combination Starter alone is a legitimate short-circuit protective device and disconnect means for the down- stream motor, while the contactor has been added to provide remote operation of the motor circuit. Accessories . . . . . . . . . . . . . . . . . . . . Page 34-130 Technical Data . . . . . . . . . . . . . . . . . . Page 34-142 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-128 XT IEC Power Control March 2009 Manual Motor Protectors 34 B-Frame �� Table 34-148. XTPT Transformer Protective Circuit Breakers — Global Ratings Type 1 and Type 2 Coordination For the protection of transformers with a high inrush current. Fixed short-circuit trip of 15 – 22 times max. settings of FLA Rated FLA Short Maximum Motor Ratings Screw Terminals Uninterrupted Adjustment Circuit Maximum kW Rating Maximum hp Rating — P (hp) Catalog Price Current — Range / Release — AC-3 — P (kW) Number U.S. $ I (Amps) Overload I (Amps) u rm 3-Phase 3-Phase Release — I (Amps) 220 – 380 – 440V 500V 660 – 200V 240V 480V 600V r 240V 415V 690V Frame B 0.16 0.1 – 0.16 2.4 — — — — — — — — — XTPTP16BC1 0.25 0.16 – 0.25 4.25 — — — — — — — — — XTPTP25BC1 0.4 0.25 – 0.4 6.8 — — — — — — — — — XTPTP40BC1 0.63 0.4 – 0.63 12 — — — — — — — — — XTPTP63BC1 1 0.63 – 1 20 — — — — — — — — — XTPT001BC1 1.6 1 – 1.6 32 — — — — — — — — — XTPT1P6BC1 2.5 1.6 – 2.5 50 — — — — — — — — — XTPT2P5BC1 4 2.5 – 4 84 — — — — — — — — — XTPT004BC1 6.3 4 – 6.3 141 — — — — — — — — — XTPT6P3BC1 10 6.3 – 10 224 — — — — — — — — — XTPT010BC1 12 8 – 12 224 — — — — — — — — — XTPT012BC1 16 10 – 16 358 — — — — — — — — — XTPT016BC1 20 16 – 20 380 — — — — — — — — — XTPT020BC1 25 20 – 25 420 — — — — — — — — — XTPT025BC1 � For manual motor protective circuit breaker switching capacity, see Page 34-147. � XTPT is not UL/CSA approved. Notes: For the protection of transformers with a high inrush current. Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Can be snap-fit to IEC/EN 60715 top-hat (DIN) with 7.5 or 15 mm height. Service Factor (SF) — Setting I of current scale in dependence of load factor: r SF = 1.15 -> I = 1 x I r n mot SF = 1 -> I = 0.9 x I r n mot Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-130 Technical Data . . . . . . . . . . . . . . . . . . Page 34-142 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-129 XT IEC Power Control March 2009 Manual Motor Protectors 34 B-Frame Table 34-149. XTPM Motor Protective Circuit Breakers for Starter Combinations — Global Ratings Type 1 and Type 2 Coordination Motor Protective Device without Overload Function � Rated FLA Short Maximum Motor Ratings Screw Terminals Uninterrupted Adjustment Circuit � Maximum kW Rating Maximum hp Rating — P (hp) Catalog Price Current — Range / Release — AC-3 — P (kW) Number U.S. $ I (Amps) Overload I (Amps) u rm 3-Phase 3-Phase Release — I (Amps) 220 – 380 – 440V 500V 660 – 200V 240V 480V 600V r 240V 415V 690V Frame B 0.16 — 2.2 — — — — 0.06 — — — — XTPMP16B 0.25 — 3.5 — 0.06 0.06 0.06 0.12 — — — — XTPMP25B 0.4 — 5.6 0.06 0.09 0.12 0.12 0.18 — — — — XTPMP40B 0.63 — 8.8 0.09 0.12 0.18 0.25 0.25 — — — — XTPMP63B 1 — 14 0.12 0.25 0.25 0.37 0.55 — — — — XTPM001B 1.6 — 22 0.25 0.37 0.55 0.75 1.1 — — — — XTPM1P6B 2.5 — 35 0.37 0.75 1.1 1.1 1.5 — — — — XTPM2P5B 4 — 56 0.75 1.5 1.5 2.2 3 — — — — XTPM004B 6.3 — 88 1.1 2.2 3 3 4 — — — — XTPM6P3B 10 — 140 2.2 4 4 4 7.5 — — — — XTPM010B 12 — 168 3 5.5 5.5 5.5 11 — — — — XTPM012B 16 — 224 4 7.5 9 9 12.5 — — — — XTPM016B 20 — 280 5.5 9 11 12.5 15 — — — — XTPM020B 25 — 350 5.5 12.5 12.5 15 22 — — — — XTPM025B 32 — 448 7.5 15 15 22 30 — — — — XTPM032B � Select Manual Motor Protectors by full load amperes. Maximum Motor Ratings (kW, hp) are for reference only. � XTPM is not UL/CSA Approved. Notes: Can be snap-fit to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. An appropriate overload relay must be fitted to protect motors against overload. Combinations of the XTPM Manual Motor Protectors and XTCE/XTCR Contactors + XTOB Overload Relays can be found in the XT Manual and Combination Motor Controllers section. When using the XTPM as short-circuit protection for motors with heavy starting duty, the rated operational current I must be derated during engineering with e the following factors: Class 5 = 1.0 Class 10 = 1.0 Class 15 = 0.82 Class 20 = 0.71 Class 25 = 0.63 Class 30 = 0.58 Class 35 = 0.53 Class 40 = 0.50 Accessories . . . . . . . . . . . . . . . . . . . . Page 34-130 Technical Data . . . . . . . . . . . . . . . . . . Page 34-142 Discount Symbol . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-130 XT IEC Power Control March 2009 Manual Motor Protectors Accessories Auxiliary Contacts Side-Mount Auxiliary Contacts 34 Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT) and can be combined with XTPAXSATR… and XTPAXFA… trip indicating auxiliary contact. Table 34-150. Side-Mount Auxiliary Contacts Contact Contact Sequence Screw Spring Cage Price � Configuration Terminals Terminals U.S. $ Pkg. Catalog Pkg. Catalog Qty. Number Qty. Number 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC11 1.21 1.13 L1 L2 L3 XTPAXSA11 1.14 1.22 1NO-2NC 5 XTPAXSA12 — — 1. 131.21 1.31 L1 L2 L3 XTPAXSA12 1. 14 1.221.32 2NO-1NC 5 XTPAXSA21 — — 1. 131.21 1.33 L1 L2 L3 XTPAXSA21 1. 14 1.221.34 � Orders must be placed in multiples of package quantity listed. Front-Mount Auxiliary Contacts Can be fitted to manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT). 45 mm (XTPR…B and XTPB) or 55 mm (XTPR…D) widths of manual motor protectors remain unchanged. Table 34-151. Front-Mount Auxiliary Contacts Contact Contact Sequence Screw Spring Cage Price � Configuration Terminals Terminals U.S. $ Pkg. Catalog Pkg. Catalog Qty. Number Qty. Number 1NO-1NC 5 XTPAXFA11 — — 1.53 1.61 L1 L2 L3 XTPAXFA11 1.54 1.62 1NO-0NC 5 XTPAXFA10 5 XTPAXFAC10 1.53 L1 L2 L3 XTPAXFA10 1.54 0NO-1NC — — 5 XTPAXFAC01 1.51 L1 L2 L3 XTPAXFAC01 1.52 � Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-131 XT IEC Power Control March 2009 Manual Motor Protectors Side-Mount Trip Indicating Auxiliary Contacts 34 Can be fitted on the right side of manual motor protectors. Can be combined with standard auxiliary contacts. Trip indication: A. General Trip indication (overload) B. Short-circuit trip. Local short-circuit indication by red indicator, manually resettable. Table 34-152. Side-Mount Trip Indicating Auxiliary Contacts Contact Contact Sequence Pkg. For Use Catalog Price � Configuration Qty. with… Number U.S. $ 2 x 1NO 2 XTPB, XTPR, XTPM, XTPT XTPAXSATR20 “+” “ ” 4.43 4.13 4.44 4.14 On/Off L1L2L3 “+” > “ ” Trip “+” L1L2L3 “+” > “ ” 2 x 1NC 2 XTPB, XTPR, XTPM, XTPT XTPAXSATR02 “+” “ ” 4.31 4.21 4.32 4.22 On/Off L1L2L3 “+” “ >” Trip “+” L1L2L3 “+” “ >” � Orders must be placed in multiples of package quantity listed. Early-Make Front-Mount Auxiliary Contacts XTPBXFAEM20 XTPAXFAEM20 For use with XTPB…, B-Frame XTPR and XTPT. Can be fitted to the front of a manual motor protector. 45 mm width of manual motor protector remains unchanged. For early energization of undervoltage release, e.g. in Emergency-Stop circuits to EN 60204. Table 34-153. Early-Make Front-Mount Auxiliary Contacts Contact Contact Sequence Pkg. For Use Catalog Price � Configuration Qty. with… Number U.S. $ 2NO 5 XTPB XTPBXFAEM20 3.13 3.23 � 2NO 2 XTPR, XTPM, XTPT XTPAXFAEM20 3.14 3.24 � Orders must be placed in multiples of package quantity listed. � Not for use with rotary handle mechanism Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-132 XT IEC Power Control March 2009 Manual Motor Protectors � Shunt Release Current Limiter C1 Contact Sequence C2 Can be used to trip the manual motor protector from a The XTPAXCL enhances the switching capacity of the XT 34 remote location. Can be fitted on the left side of manual manual motor protectors. It can be used with the XTPB, motor protectors. Cannot be combined with the XTPAXUVR. XTPR...BC1, XTPR...DC1 for individual or group protections. DC: Intermittent operation 5 sec. The rated uninterrupted current is 63A for IEC and 25A for UL/CSA. It can be mounted next to or behind the manual Table 34-154. Shunt Release motor protector. See Tables 34-184 and 34-185 for ratings Catalog Catalog Pkg. Price when using the current limiter. � Number — Number — Qty. U.S. $ Screw Terminals Spring Cage Terminals Table 34-156. Current Limiter XTPAXSR24V50H — 2 Description Contact Pkg. Catalog Price XTPAXSR48V50H — 2 Sequence Qty. Number U.S. $ XTPAXSR110V50H — 2 XTPAXSR120V60H — 2 To enhance the switch- 1 XTPAXCL XTPAXSR208V60H — 2 L ing capacity of non- XTPAXSR220V50H — 2 inherently safe 10 – XTPAXSR230V50H XTPAXSRC230V50H 2 25A Manual Motor XTPAXSR240V50H — 2 Protectors to 150 kA/ T XTPAXSR240V60H — 2 440V XTPAXSR380V50H — 2 � XTPAXSR400V50H — 2 Max. rated operation voltage U = 690V, rated uninterrupted current e XTPAXSR415V50H — 2 I = 63A. Can be used for individual and group protection. For group u XTPAXSR440V60H — 2 protection and in combination with the XTPR…D, order additional XTPAXSR480V60H — 2 XTPAXIT incoming terminal if required. Mounting next to or behind the XTPAXSR24VDC XTPAXSRC24VDC 2 manual motor protector. 16 – 63A XTPR...D: 100 kA/400V, 10 kA/690V. XTPAXSR48VDC — 2 XTPAXSR60VDC — 2 Lockable Rotary Handle XTPAXSR110VDC — 2 XTPAXSR125VDC — 2 XTPAXSR220VDC — 2 XTPAXSR250VDC — 2 � Orders must be placed in multiples of package quantity listed. Table 34-157. Replacement Lockable Rotary Handle Undervoltage Release Description Pkg. Catalog Price D1 � Qty. Number U.S. $ Lockable Rotary Handle that mounts 5 XTPAXLRH Contact Sequence directly to the XTPR manual motor U protectors. Comes standard with XTPR. � D2 Orders must be placed in multiples of package quantity listed. Can be used to trip the manual motor protector from a remote location. Can be fitted on left side manual motor protectors. Cannot be combined with XTPAXSR. When com- bined with a circuit breaker, it can be used as Emergency- Stop device to IEC/EN 60204. Table 34-155. Undervoltage Release Catalog Catalog Pkg. Price � Number — Number — Qty. U.S. $ Screw Terminals Spring Cage Terminals XTPAXUVR24V50H — 2 XTPAXUVR24V60H — 2 XTPAXUVR48V50H — 2 XTPAXUVR60V50H — 2 XTPAXUVR110V50H — 2 XTPAXUVR120V60H — 2 XTPAXUVR208V60H — 2 XTPAXUVR220V50H — 2 XTPAXUVR230V50H XTPAXUVRC230V50H 2 XTPAXUVR240V50H — 2 XTPAXUVR240V60H — 2 XTPAXUVR380V50H — 2 XTPAXUVR400V50H — 2 XTPAXUVR415V50H — 2 XTPAXUVR440V60H — 2 XTPAXUVR480V60H — 2 XTPAXUVR600V60H — 2 � Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-133 XT IEC Power Control March 2009 Manual Motor Protectors IP65 Rotary Handle Mechanism ���� Table 34-158. IP65 Rotary Handle Mechanism Description Enclosure Pkg. Catalog Price � Rating Qty. Number U.S. $ Complete Kits — Includes Handle, Shaft, and Required Hardware � Rotary Handle Mechanism — Black. IP65 1 XTPAXRHMB � NEMA 12 Rotary Handle Mechanism — Red/Yellow. 1 XTPAXRHMRY 34 UL/CSA 4X Rotary Handle Mechanism — Black 1 XTPAXRHM90B � — Rotated 90° from Vertical. Rotary Handle Mechanism — Red/Yellow 1 XTPAXRHM90RY � — Rotated 90° from vertical. Separate Parts � Rotary Handle Only — Black. IP65 10 XTPAXRHB10 NEMA 12 � Rotary Handle Only — Red/Yellow. 10 XTPAXRHRY10 UL/CSA 4X Rotary Handle Only — Black 10 XTPAXRH90B10 � — Rotated 90° from vertical. Rotary Handle Only — Red/Yellow 10 XTPAXRH90RY10 � — Rotated 90° from vertical. Shaft Only — Includes Shaft to mount to XTPR, —10 XTPAXRHMSFT 175 mm length. Shaft Only — Includes Shaft to mount to XTPR, —50 XTPAXRHMSFTB72 72 mm length, minimum 50 pcs. — Bulk Pack. Shaft Only — Includes Shaft to mount to XTPR, —50 XTPAXRHMSFTB98 98 mm length, minimum 50 pcs. — Bulk Pack. � Plug-in connection shafts, XTPAXRHMSFT_ can be cut to desired length for mounting depths of 100 – 240 mm. Carrier with extension shaft included. � With ON/OFF switch position and “+” (tripped), lockable with 3 padlocks, 4 – 8 mm hasp. Can be locked in the OFF position, if required. � Rotary Handle Mechanisms ship with door interlock disabled. See instruction publication with product for how to enable door interlock. � Not for use with XTPAXFAEM20 early-make front mount auxiliary contact. � Orders must be placed in multiples of package quantity listed. � For use on main switches to IEC/EN 60204. � For use on main switches with Emergency-Stop function to IEC/EN 60204. Sealing Facility Table 34-159. Sealing Facility Description Pkg. Catalog Price � Qty. Number U.S. $ To prevent tampering with the overload 5 XTPAXSW release and the test function. It can be sealed using industry standard sealing wire. For use with XTPR manual motor protectors. � Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-134 XT IEC Power Control March 2009 Manual Motor Protectors Three-Phase Commoning Links Frame B Frame D 34 For parallel power feed to several manual motor protectors on terminals 1, 3 and 5. � Table 34-160. Three-Phase Commoning Links For Use Qty. Length of Unit Pkg. Catalog Price � with… MMP Link (mm) Width (mm) Qty. Number U.S. $ Frame B MMP with no side mounted 2 904510 XTPAXCLKA2 auxiliaries or voltage releases 3 135 45 10 XTPAXCLKA3 418045 10 XTPAXCLKA4 5 225 45 10 XTPAXCLKA5 Each MMP with one auxiliary 2 99 45 + 9 10 XTPAXCLKB2 contact or trip-indicating auxiliary contact fitted on the right 3 153 45 + 9 10 XTPAXCLKB3 4 207 45 + 9 10 XTPAXCLKB4 5 261 45 + 9 10 XTPAXCLKB5 Each MMP with an auxiliary contact 2108 45 + 18 10 XTPAXCLKC2 and trip-indicating auxiliary contact mounted on the right or a voltage 4 234 45 + 18 10 XTPAXCLKC4 release mounted on the left. Frame D MMP with no side mounted 2 110 55 1 XTPAXCLKA2D auxiliaries or voltage releases 3 165 55 1 XTPAXCLKA3D 4 220 55 1 XTPAXCLKA4D Each MMP with one auxiliary 2 119 55 + 9 1 XTPAXCLKB2D contact or trip-indicating auxiliary contact fitted on the right 3183 55 + 9 1 XTPAXCLKB3D 4 247 55 + 9 1 XTPAXCLKB4D Each MMP with an auxiliary contact 2128 55 + 18 1 XTPAXCLKC2D or trip-indicating auxiliary contact mounted on the right or a voltage release mounted on the left. 4 274 55 + 18 1 XTPAXCLKC4D � Protected against accidental contact. B-Frame short circuit proof Ue = 690V, I = 63A; D-Frame short circuit proof Ue = 690V, I = 128A. Frame B links u u can be combined by rotating mounting. Frame D links cannot be combined. � Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-135 XT IEC Power Control March 2009 Manual Motor Protectors Shroud for Unused Commoning Link Terminals Table 34-161. Shroud for Unused Terminals of Three-Phase Commoning Links For Use Description Pkg. Catalog Price � with… Qty. Number U.S. $ B-Frame To cover unused terminals 20 XTPAXUTS XTPR on three-phase common- ing link. Protected against D-Frame 10 XTPAXUTSD 34 direct contact. XTPR � Orders must be placed in multiples of package quantity listed. � Incoming Terminal for Three-Phase Commoning Link Table 34-162. Incoming Terminal For Use Pkg. Catalog Price � with… Qty. Number U.S. $ B-Frame XTPR, XTPB 5 XTPAXIT � For three-phase commoning link, protected against accidental contact, U = 690V, I = 63A; For e u 2 2 conductor cross-sections: 2.5 – 25 mm stranded; 2.5 – 16 mm flexible with ferrules, AWG 14-6. � Orders must be placed in multiples of package quantity listed. � Line-Side Adapter Table 34-163. Line-Side Adapter For Use Pkg. Catalog Price � with… Qty. Number U.S. $ B-Frame XTPR to create a UL 508 Type 5 XTPAXLSA E/F Manual Combination Starter � D-Frame XTPR to create a UL 508 Type 1 XTPAXLSAD E/F Manual Combination Starter � XTPAXLSA is for three-phase commoning link, finger- and back-of-hand proof, U = 690V, I = 60A for e u 2 2 conductor cross sections: 2.5 – 25 mm stranded, 2.5 – 16 mm flexible with ferrule, AWG 14-6. � Orders must be placed in multiples of package quantity listed. � XTPAXLSAD cannot be combined with three-phase commoning links. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-136 XT IEC Power Control March 2009 Manual Motor Protectors Combination Connection Kits Table 34-164. Combination Connection Kits For Use Description Std. Catalog Price with… Pack Number U.S. $ Non-reversing Starters XTPR...B + XTCE...B Comprised of: 1 XTPAXTPCB ■ Mechanical connection element for XTPR...B and 34 contactor ■ Main current wiring between XTPR...B and contactor in tool-less plug connection ■ Cable guidance Use contactor auxiliary switch XTCEXFAT_. 2 Control cable guidance: max. 6 cables up to 2.5 mm 2 external diameter or 4 cables up to 3.5 mm external diameter. XTPR...B + XTCE...C Comprised of: 1 XTPAXTPCC ■ DIN rail adapter plate XTPR...D + XTCE...D 1 XTPAXTPCD ■ Main current wiring between XTPR and contactor Reversing Starters XTPR...B + XTCE...B01_ Comprised of: 1 XTPAXTPCRB ■ Mechanical connection element for XTPR...B and contactor ■ Reversing starter main current wiring in tool-less plug connection ■ Control cables for electrical interlocking in tool- less plug connection: – K1M: A1 – K2M: 21 – K1M: 21 – K2M: A1 – K1M: A2 – K2M: A2 ■ Cable guidance Use contactor auxiliary switch XTCEXFAT_. 2 Control cable guidance: max. 6 cables up to 2.5 mm 2 external diameter or 4 cables up to 3.5 mm external diameter. XTPR...B + XTCE...C Comprised of: 1 XTPAXTPCRC ■ DIN rail adapter plate ■ Reversing starter main current wiring Star-Delta Starter Sets XTPR...B + XTCE...B Comprised of: 1 XTPAXSDSB ■ DIN rail adapter plate ■ Main current wiring between XTPR...B and contactor ■ Electrical interlock between delta and star contactor ■ Use as contactor auxiliary switch XTCEXFAT_ XTPR...B + XTCE...C Comprised of: 1 XTPAXSDSC ■ DIN rail adapter plate ■ Main current wiring between XTPR...B and contactor Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-137 XT IEC Power Control March 2009 Manual Motor Protectors Combination Connection Kits Table 34-164. Combination Connection Kits (Continued) For Use Description Std. Catalog Price � with… Pack Number U.S. $ Electrical Connection Module XTPR...B + XTCE...C Comprised of: 5 XTPAXECMC ■ Main current wiring between XTPR...B and contactor 34 ■ Use only in combination with busbar adapter XTPR...D + XTCE...D Comprised of: 5 XTPAXECMD ■ Main current wiring between XTPR...D and contactor ■ Use only in combination with busbar adapter DIN Rail Adapter Plates XTPAXTPCB Comprised of: 4 XTPAXTPCPB XTPAXTPCRB ■ 45 mm wide adapter plate with one DIN rail ■ Connection element for side-by-side positioning of further plates XTPR...B + XTCE...C Comprised of: 4 XTPAXTPCRPB XTPAXECMC ■ 45 mm wide adapter plate with two DIN rails ■ Connection element for side-by-side positioning of further plates XTPAXECMD Comprised of: 4 XTPAXTPCPD XTPR...D + XTCE...C ■ 55 mm wide adapter plate with two DIN rails XTPR...D + XTCE...D ■ Connection cams for further plates ■ For use with reversing and star-delta starters Lateral Module — ■ Can be grouped on the DIN rail adapter 10 XTPAXLM ■ Expansion of the mounting width by 9 mm Connection Element — ■ For connection of several DIN rail adapters 50 XTPAXCNE � Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-138 XT IEC Power Control March 2009 Manual Motor Protectors Pushbutton MMP Enclosures B-Frame 34 � Table 34-165. Insulated Enclosures for Surface Mounting of XTPB Pushbutton Motor-Protective Circuit Breakers — Global Usage Degree of For Use Description Catalog Price Approx. Dimensions Protection with… Number U. S. $ mm [in] H x W x D IP40 XTPB MMP Only or with: — XTPBXENCS40 158 x 80 x 116.5 NEMA 1 XTPAXFA…, XTPBXFAEM20, [6.22 x 3.15 x 4.59] XTPAXSA..., XTPAXUVR..., XTPAXSR... IP65 With actuation membrane. XTPBXENCS65 158 x 80 x 116.5 NEMA [6.22 x 3.15 x 4.59] 3R, 4X, 12, 13 IP65 XTPB MMP Only or with: Lockable in OFF position. XTPBXENCSLO65 158 x 80 x 129.5 NEMA XTPAXFA…, XTPAXUVR…, [6.22 x 3.15 x 5.10] 3R, 4X, 12, 13 XTPAXSR…, XTPAXCL IP65 XTPB MMP Only or with: Lockable in OFF position in XTPBXENCSLE65 158 x 80 x 129.5 NEMA XTPAXFA…, XTPBXFAEM20, combination with XTPBXFAEM20 [6.22 x 3.15 x 5.10] 3R, 4X, 12, 13 XTPAXUVR..., XTPAXSR…, Early Make front mount auxiliary XTPAXCL contact IP65 With Emergency-Stop (E-Stop) XTPBXENCSES65 158 x 80 x 177.2 NEMA pushbutton actuator, Red-Yellow [6.22 x 3.15 x 6.98] 3R, 4X, 12, 13 IP65 With Emergency-Stop (E-Stop) XTPBXENCSEK65 158 x 80 x 177.2 NEMA pushbutton actuator, Red-Yellow key [6.22 x 3.15 x 6.98] 3R, 4X, 12, 13 release � Integrated terminal for PE(N) connection, two M25 cable entry knockouts at top and at bottom. �� Table 34-166. Insulated Enclosures for Surface Mounting of XTPB Pushbutton Manual Motor Protectors — North American Usage Degree of For Use Description Catalog Price Approx. Dimensions Protection with… Number U. S. $ mm [in] H x W x D IP41 XTPB MMP Only or with: — XTPBXENAS41 158 x 80 x 116.5 NEMA 1 XTPAXFA…, XTPBXFAEM20, [6.22 x 3.15 x 4.59] XTPAXSA..., XTPAXUVR..., XTPAXSR…, XTPAXCL IP65 With actuating diaphragm XTPBXENAS65 158 x 80 x 116.5 NEMA [6.22 x 3.15 x 4.59] 3R, 4X, 12, 13 IP65 XTPB MMP Only or with: Lockable in OFF position XTPBXENASLO65 158 x 80 x 129.5 NEMA XTPAXFA…, XTPAXUVR…, [6.22 x 3.15 x 5.10] 3R, 4X, 12, 13 XTPAXSR…, XTPAXCL IP65 XTPB MMP Only or with: Lockable in OFF position in combina- XTPBXENASLE65 158 x 80 x 129.5 NEMA XTPAXFA…, XTPBXFAEM20, tion with XTPBXFAEM20 Early Make [6.22 x 3.15 x 5.10] 3R, 4X, 12, 13 XTPAXUVR..., XTPAXSR…, front mount auxiliary contact. XTPAXCL IP65 With Emergency-Stop (E-Stop) XTPBXENASES65 158 x 80 x 177.2 NEMA pushbutton actuator, Red-Yellow [6.22 x 3.15 x 6.98] 3R, 4X, 12, 13 IP65 With Emergency-Stop (E-Stop) XTPBXENASEK65 158 x 80 x 177.2 NEMA pushbutton actuator, Red-Yellow key [6.22 x 3.15 x 6.98] 3R, 4X, 12, 13 release � Built-in terminal for PE(N). � North American enclosures come with conduit adapters for use with 1/2" NPT. Dimensions . . . . . . . . . . . . . . . . . . . . . Page 34-150 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-139 XT IEC Power Control March 2009 Manual Motor Protectors � Table 34-167. Insulated Enclosures for Flush Mounting of XTPB Pushbutton Manual Motor Protectors — Global and North American Usage Degree of For Use Description Catalog Price Approx. Dimensions Protection with… Number U. S. $ mm [in] H x W x D Front IP40 XTPB Only or with: — XTPBXENCF40 129 x 90.2 x 115.2 NEMA 1 XTPAXFA…, XTPBXFAEM20, [5.08 x 3.55 x 4.54] XTPAXSA…, XTPAXUVR…, XTPAXSR…, XTPAXCL 34 Front IP65 With actuation membrane XTPBXENCF55 129 x 90.2 x 115.2 NEMA [5.08 x 3.55 x 4.54] 3R, 4X, 12, 13 Front IP65 XTPB Only or with: Lockable in OFF position XTPBXENCFLO55 129 x 90.2 x 115.2 NEMA XTPAXFA…, XTPAXUVR…, [5.08 x 3.55 x 4.54] 3R, 4X, 12, 13 XTPAXSR…, XTPAXCL Front IP65 XTPB Only or with: Lockable in OFF position in combina- XTPBXENCFLE55 129 x 90.2 x 115.2 NEMA XTPAXFA…, XTPBXFAEM20, tion with XTPBXFAEM20 Early Make [5.08 x 3.55 x 4.54] 3R, 4X, 12, 13 XTPAXUVR…, XTPAXSR…, front mount auxiliary contact XTPAXCL Front IP65 With Emergency-Stop (E-Stop) XTPBXENCFES55 129 x 90.2 x 175.9 NEMA pushbutton actuator [5.08 x 3.55 x 6.93] 3R, 4X, 12, 13 Front IP65 With Emergency-Stop (E-Stop) XTPBXENCFEK55 129 x 90.2 x 175.9 NEMA pushbutton actuator, key release [5.08 x 3.55 x 6.93] 3R, 4X, 12, 13 � Integrated terminal for PE(N) connection. Rotary MMP Enclosures B-Frame D-Frame Table 34-168. Insulated Enclosures for Surface Mounting of B-Frame (0.1 – 32A) XTPR Rotary Motor-Protective Circuit Breakers — Global Usage Degree of For Use Description Catalog Price Approx. Dimensions Protection with… Number U. S. $ mm [in] H x W x D � IP41 with B-Frame XTPR Only or with: Cover with aperture dimensioned to XTPAXENCS41 160 x 100 x 104 vertical XTPAXFA…, XTPAXSA…, accommodate front of MMP. IP40, [6.30 x 3.94 x 4.09] mounting XTPAXSATR…, when mounted turned through 90° to XTPAXUVR…, XTPAXSR…, left/right XTPAXCL � IP65 With black/grey rotary handle XTPAXENCS65B 160 x 100 x 130 [6.30 x 3.94 x 5.12] � IP65 With red/yellow rotary handle for use XTPAXENCS65RY 160 x 100 x 130 as Emergency-Stop switches to IEC/ [6.30 x 3.94 x 5.12] EN 60204 � IP40 B-Frame XTPR Only or with: Cover with aperture dimensioned to XTPAXENCS40 158 x 80 x 100 XTPAXSA…, XTPAXUVR…, accommodate front of MMP. [6.22 x 3.15 x 3.94] XTPAXSR…, XTPAXCL � IP55 B-Frame XTPR Only or with: With black/gray rotary handle XTPAXENCS55B 158 x 80 x 125.5 XTPAXFA…, XTPAXSA…, [6.22 x 3.15 x 4.94] XTPAXUVR…, XTPAXSR…, � IP55 With red/yellow rotary handle for use XTPAXENCS55RY 158 x 80 x 125.5 XTPAXCL as Emergency-Stop switches to IEC/ [6.22 x 3.15 x 4.94] EN 60204 � M25 metric cable entry knock-out, top and bottom. Cable push-through membrane, top and bottom, in the back plate and as a control line entry. Includes N and PE terminals. � Integrated terminal for PE(N) connection, two M25 cable entry knockouts at the top and bottom. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-140 XT IEC Power Control March 2009 Manual Motor Protectors � Table 34-169. Insulated Enclosures for Surface Mounting of B-Frame (0.1 – 32A) XTPR Rotary Manual Motor Protectors — North American Usage Degree of For Use Description Catalog Price Approx. Dimensions Protection with… Number U. S. $ mm [in] H x W x D IP55 B-Frame XTPR Only or with: With black/gray rotary handle XTPAXENAS55B 160 x 100 x 130 NEMA 1, 12, 3R XTPAXSA…and XTPAXFA…, [6.30 x 3.94 x 5.12] XTPAXUVR…and With red/yellow rotary handle for XTPAXENAS55RY 160 x 100 x 130 XTPAXFA…, XTPAXSR…and use as Emergency-Stop switch to [6.30 x 3.94 x 5.12] 34 XTPAXFA…, XTPAXCL VDE 0113 � Built-in N and PE terminal, lower part without knockouts. Table 34-170. Insulated Enclosures for Surface Mounting of B-Frame XTPR (0.1 – 32A) Rotary Motor-Protective Circuit Breakers with XTPAXFAEM20 Early-Make Front Mount Auxiliary Contact — Global Usage Degree of For Use Description Catalog Price Approx. Dimensions Protection with… Number U. S. $ mm [in] H x W x D IP65 B-Frame XTPR and With black/gray rotary handle XTPAXENCSEM65B 160 x 100 x 130 XTPAXFAEM20 only or with: [6.30 x 3.94 x 5.12] XTPAXFA…, XTPAXSA…, IP65 With red/yellow rotary handle for XTPAXENCSEM65RY 160 x 100 x 130 XTPAXSATR…, use as Emergency-Stop switches to [6.30 x 3.94 x 5.12] XTPAXUVR…, XTPAXSR…, IEC/EN 60204 XTPAXCL IP55 B-Frame XTPR and With black/gray rotary handle XTPAXENCSEM55B 158 x 80 x 100 XTPAXFAEM20 only or with: [6.22 x 3.15 x 3.94] XTPAXFA…, XTPAXUVR…, IP55 With red/yellow rotary handle for XTPAXENCSEM55RY 158 x 80 x 100 XTPAXSR…, XTPAXCL use as Emergency-Stop switches to [6.22 x 3.15 x 3.94] IEC/EN 60204 Table 34-171. Insulated Enclosures for Surface Mounting of B-Frame XTPR (0.1 – 32A) Rotary Manual Motor Protectors with XTPAXFAEM20 Early- � Make Front Mount Auxiliary Contact — North American Usage Degree of For Use Description Catalog Price Approx. Dimensions Protection with… Number U. S. $ mm [in] H x W x D IP55 B-Frame XTPR Only or with: With black/grey rotary handle XTPAXENASEM55B 160 x 100 x 130 NEMA 1, 12, 3R XTPAXSA…, XTPAXUVR…, [6.30 x 3.94 x 5.12] XTPAXCL With red/yellow rotary handle for XTPAXENASEM55RY 160 x 100 x 130 use as Emergency-Stop switch to [6.30 x 3.94 x 5.12] VDE 0113 � Built-in N and PE terminal, lower part without knockouts. � Table 34-172. Insulated Enclosures for Flush Mounting of B-Frame (0.1 – 32A) XTPR Rotary Manual Motor Protectors — Global Usage Degree of For Use Description Catalog Price Approx. Dimensions Protection with… Number U. S. $ mm [in] H x W x D Front IP40 B-Frame XTPR Only or with: Cover with aperture dimensioned to XTPAXENCF40 129 x 85 x 96 XTPAXSA…, XTPAXUVR…, accommodate front of MMP. [5.08 x 3.35 x 3.78] XTPAXSR…, XTPAXCL Front IP55 B-Frame XTPR Only or with: With black/gray rotary handle XTPAXENCF55B 129 x 85 x 124 XTPAXSA…, XTPAXUVR…, [5.08 x 3.35 x 4.88] XTPAXSR…, XTPAXFA…, With red/yellow rotary handle for XTPAXENCF55RY 129 x 85 x 124 XTPAXCL use as Emergency-Stop switches to [5.08 x 3.35 x 4.88] IEC/EN 60204 � Integrated terminal for PE(N) connection. �� Table 34-173. Insulated Enclosures for Surface Mounting of D-Frame (10 – 65A) Rotary Motor-Protective Circuit Breakers Degree of For Use Description Catalog Price Approx. Dimensions Protection with… Number U. S. $ mm [in] H x W x D IP65 D-Frame XTPR Only or with: With black/gray rotary handle XTPAXENCSD65B 240 x 160 x 197 NEMA 1, 12, 3R, XTPAXFA…, XTPAXFAEM20, [9.45 x 6.30 x 7.76] 4X XTPAXSA…, XTPAXSATR…, XTPAXUVR…, XTPAXSR…, IP65 With red/yellow rotary handle for XTPAXENCSD65RY 240 x 160 x 197 XTPAXCL NEMA 1, 12, 3R, use as Emergency-Stop switches to [9.45 x 6.30 x 7.76] 4X IEC/EN 60204 � Integrated terminal for PE(N) connection. � Metric knockouts: Top ÷ bottom: M25/M32 In backplate: M25/M32 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 Control cable entry: M20 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-141 XT IEC Power Control March 2009 Manual Motor Protectors MMP Enclosure Accessories Table 34-174. XTPR Manual Motor Protector Enclosure Padlock Attachment For Use Description Pkg. Catalog Price � with… Qty. Number U. S. $ � XTPAXENCS65B, Padlocking feature. Up to 3 padlocks with 3 XTPAXPL1 XTPAXENCS65RY, 3 – 6 mm hasp thickness. For use as main switch XTPAXENCSEM65B, to IEC/EN 60204. XTPAXENCSEM65RY, 34 XTPAXENCS55B, XTPAXENCS55RY, XTPAXENCSEM55B, XTPAXENCSEM55RY � XTPAXENCSD65B, 1 XTPAXPL2 XTPAXENCSD65RY � XTPAXENCF55B, 3 XTPAXPL3 XTPAXENCF55RY � Orders must be placed in multiples of package quantity listed. � Lockable in the 0-position of the XTPR manual motor protector. � Lockable in the OFF position of the B-Frame XTPR manual motor protector. Table 34-175. Neutral Terminal for use with XTPB and B-Frame XTPR Flush-Mount Enclosures For Use Description Pkg. Catalog Price � with… Qty. Number U. S. $ XTPBXENCF40, For connection of a fifth conductor 20 XTPAXNT XTPBXENCF55, XTPAXENCF40, XTPAXENCF55B, XTPAXENCF55RY � Orders must be placed in multiples of package quantity listed. Metric Cable Glands to EN 50262 Indicating Lights with Neon Bulb ■ For use with XTPR and XTPB enclosures ■ With locknut and internal strain relief ■ Lights do not carry individual IP or NEMA rating. All enclo- ■ IP68 up to 5 bar, hydrogen free sure ratings remain valid when using indicating lights. Table 34-176. Metric Cable Glands Table 34-178. Indicating Lights Description Pkg. Catalog Price Color Description — Pkg. Catalog Price � Qty. Number U.S. $ � Indicating Light Qty. Number U.S. $ 20.5 mm Metric Cable Gland 20 XTPAXMCG20 6 – 13 mm Wire White 110 – 230V 10 XTPAXILWB 230 – 240V 10 XTPAXILWN 25.5 mm Metric Cable Gland 20 XTPAXMCG25 415 – 500V 10 XTPAXILWC 9 – 17 mm Wire Green 110 – 230V 10 XTPAXILGB 32.5 mm Metric Cable Gland 10 XTPAXMCG32 13 – 21 mm Wire 230 – 240V 10 XTPAXILGN 415 – 500V 10 XTPAXILGC 32.5 mm Metric Cable Gland 10 XTPAXMCG32G 18 – 25 mm wire Red 110 – 230V 10 XTPAXILRB � Orders must be placed in multiples of package quantity listed. 230 – 240V 10 XTPAXILRN 415 – 500V 10 XTPAXILRC � � IP65 Metric Diaphragm Grommet Orders must be placed in multiples of package quantity listed. ■ IP65 ■ With internal push-through diaphragm Table 34-177. IP65 Metric Diaphragm Grommet Description Pkg. Catalog Price � Qty. Number U.S. $ 20.5 mm Diaphragm Grommet 100 XTPAXMDG20 1 – 13 mm Wire 25.5 mm Diaphragm Grommet 100 XTPAXMDG25 1 – 18 mm Wire 32.5 mm Diaphragm Grommet 100 XTPAXMDG32 1 – 24 mm Wire � With integral push-through diaphragm. � Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-142 XT IEC Power Control March 2009 Manual Motor Protectors Technical Data and Specifications Table 34-179. XT Manual Motor Protectors — Technical Data and Specifications Description XTPBP16B – XTPRP16B – XTPR016D – XTPMP16B – XTPTP16B – XTPB016B XTPR032B XTPR063D XTPM032B XTPT025B General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 34 Climatic proofing Damp heat, constant, to IEC 60068-2-78; damp heat, cyclic, to IEC 60068-2-30 Ambient temperature, °C Storage -25 / 80 -25 / 80 -25 / 70 -25 / 80 -25 / 80 Open -25 / 55 -25 / 55 -25 / 55 -25 / 55 -25 / 55 Enclosed -25 / 40 -25 / 40 -25 / 40 -25 / 40 -25 / 40 Mounting position 90° 90° 90° 90° 90° 90° 90° 90° Direction of incoming supply As required As required As required As required As required Degree of protection Device IP20 IP20 IP20 IP20 IP20 Terminals IP00 IP00 IP00 IP00 IP00 Protection against direct contact Finger- and back-of-hand proof Shock resistance half-sinusoidal shock 25 25 15 25 25 10 mS to IEC 60068-2-27 (g) Altitude (m), maximum 2000 2000 2000 2000 2000 Terminal capacity 2 Solid (mm ) 1 x (1 – 6) 1 x (1 – 6) 1 x (1 – 50) 1 x (1 – 6) 1 x (1 – 6) 2 x (1 – 6) 2 x (1 – 6) 2 x (1 – 35) 2 x (1 – 6) 2 x (1 – 6) 2 Flexible with ferrule to DIN 46228, (mm ) 1 x (1 – 6) 1 x (1 – 6) 1 x (1 – 35) 1 x (1 – 6) 1 x (1 – 6) 2 x (1 – 6) 2 x (1 – 6) 2 x (1 – 35) 2 x (1 – 6) 2 x (1 – 6) Solid or stranded (AWG) 18 – 10 18 – 10 14 – 2 18 – 10 18 – 10 Terminal screw tightening torque Main cable, Nm 1.7 1.7 3 1.7 1.7 Main cable, lb-in 15.0 15.0 26.6 15.0 15.0 Control circuit cable, Nm 1 1 1 1 1 Control circuit cable, lb-in 8.9 8.9 8.9 8.9 8.9 Main contacts Rated impulse withstand voltage (U ), V AC 6000 6000 6000 6000 6000 imp Overvoltage category / pollution degree III / 3 III / 3 III / 3 III / 3 III / 3 Rated operational voltage (U ), V AC 690 690 690 690 690 e Rated uninterrupted current = rated operational 25 or current setting 32 or current setting 63 or current setting 32 or current setting 25 or current setting current (I = I ) in amperes of the overcurrent of the overcurrent of the overcurrent of the overcurrent of the overcurrent u e release release release release release Rated frequency, Hz 40 – 60 40 – 60 40 – 60 40 – 60 40 – 60 Current heat loss (3-pole at operating 6622 66 temperature), W Lifespan, mechanical (ops) 50,000 100,000 30,000 100,000 100,000 Lifespan, electrical (AC-3 at 400 V) (ops) 50,000 100,000 30,000 100,000 100,000 Maximum operating frequency, operations/hr 25 40 40 40 40 Short-circuit rating AC See Page 34-147. DC (kA) 60 60 (up to 60 60 (up to 60 (up to XTPT016B) XTPR016B) XTPM016B) 40 (XTPT020B – 40 (XTPR020B – 40 (XTPM020B – XTPT025B) XTPR032B) XTPR032B) Motor switching capacity AC-3 (up to 690 V) in amperes 25 32 65 32 25 DC-5 (up to 250 V) in amperes 25 25 (3 contacts in 63 (3 contacts in series) series) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-143 XT IEC Power Control March 2009 Manual Motor Protectors Table 34-179. XT Manual Motor Protectors — Technical Data and Specifications (Continued) Description XTPBP16B – XTPRP16B – XTPR016D – XTPMP16B – XTPTP16B – XTPB016B XTPR032B XTPR063D XTPM032B XTPT025B Releases Overload release setting range (x I ) 0.6 – 1.0 0.6 – 1.0 0.6 – 1.0 — 0.6 – 1.0 u Fixed short-circuit release (x I) 1414141420 u Short-circuit release tolerance ± 20% ± 20% ± 20% ± 20% ± 20% 34 Phase-failure sensitivity IEC/EN 60947-1-1, VDE 0660 Part 102 — IEC/EN 60947-1-1, VDE 0660 Part 102 Temperature compensation to IEC/EN 60947, VDE 0660, °C -5 / 40 -5 / 40 -5 / 40 -5 / 40 -5 / 40 Operating range, °C -25 / 55 -25 / 55 -25 / 55 -25 / 55 -25 / 55 Temperature compensation residual < 0.25 < 0.25 < 0.25 < 0.25 < 0.25 error for T > 20°C, %/K Table 34-180. Auxiliary Contacts — Technical Data and Specifications Description XTPAXSA_ _ XTPAXFA_ _ XTPA(B)XFAEM_ _ XTPAXSATR_ _ Rated Impulse withstand voltage, U (V AC) 6000 4000 4000 6000 imp Overvoltage category/pollution degree III/3 III/3 III/3 III/3 Rated operational voltage U (VAC) 500 440 440 500 e U (VDC) 250 250 250 250 e Safe isolation to VDE 0106 Part 101 and Part 101/A1 Between auxiliary contacts and main contacts (V AC) 690 690 690 690 Rated operational current AC-15 220 – 240 V, I (A) 3.5 1 1 3.5 e 380 – 415 V, I (A) 2 — — 2 e 440 – 500 V, I (A) 1 — — 1 e DC-13 L/R < 100 ms 24 V, I (A) 2 2 2 2 e 60 V, I (A) 1.5 — — 1.5 e 110 V, I (A) 1 — — 1 e 220 V, I (A) 0.25 — — 0.25 e Lifespan 6 Mechanical, operations (x 10 ) 0.1 0.1 0.1 0.01 6 Electrical, operations (x 10 ) 0.05 0.1 0.1 0.005 -8 8 Contact reliability (@ U = 24V DC, U – 17V, < 10 < 1 fault at 1 x 10 operations e min I = 5.4 mA, fault probability (λ) min Positively driven contacts to ZH 1/457 Yes — — — Short-circuit rating without welding Fuseless FAZ-B4/1-HI — — FAZ-B4/1-HI Fuse (A gG/gL) 10 10 10 10 Terminal Capacity 2 Solid or flexible conductor with ferrule (mm ) 0.75 –2.5 0.75 – 1.5 0.75 – 1.5 0.75 – 2.5 Solid or stranded (AWG) 18 – 14 18 – 16 18 – 16 18 – 14 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-144 XT IEC Power Control March 2009 Manual Motor Protectors Table 34-181. Undervoltage Release — Technical Data and Table 34-183. Shunt Release — Technical Data and Specifications Specifications Description XTPAXSR __ Description XTPAXUVR… Cross-sections Cross-sections 2 Solid or flexible conductor with ferrule (mm ) 1 x (0.75 – 2.5) 2 2 x (0.75 – 2.5) Solid or flexible conductor with ferrule (mm ) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) Solid or stranded (AWG) 1 x (18 – 14) 2 x (18 – 14) Solid or stranded (AWG) 1 x (18 – 14) 2 x (18 – 14) Main Contacts 34 Main Contacts Rated operational voltage, U (V AC) 42 – 480 e Rated operational voltage, U (V AC) 42 – 480 e Rated operational voltage, U (V DC) 24 – 250 e Rated operational voltage, U (V DC) 24 – 250 e AC Operating Range, x U 0.7 – 1.1 s Pick-up voltage, x U 0.85 – 1.1 s DC Operating Range, x U (intermittent operation 5s) 0.7 – 1.1 s Drop-out voltage, x U 0.7 – 0.35 s Power Consumption Power Consumption Pick-up AC (VA) 5 Pick-up AC (VA) 5 Sealing AC (VA) 3 Sealing AC (VA) 3 Pick-up DC (VA) 3 Sealing DC (VA) 3 Table 34-182. Current Limiter Description XTPAXCL 100 Rated Impulse withstand Voltage (U ), V AC 6000 imp XTPR…B XTPR...B Overvoltage Category/ Pollution Degree III/3 415V AC Inherently Rated operational voltage, U (V AC) 690 e short-circuit-proof Back-up protection Rated interrupted current = Rated operational current 63 50 range (l = l ) in amperes u e with XTPAXCL 30 20 16 Rated 13 5 13 5 short-circuit breaking 10 capacity 6 I > I > I > I > I > I > range 24 6 24 6 XTPR…B 0.16... 101620 25 Rated Figure 34-103. XTPB, XTPR 1- and 2-Pole Circuits with DC and Current AC Current n [A] 100 XTPR…D Min. Cross-Section Protected Device XTPR...D + XTPAXCL 415V AC 2 380-415V, 50 Hz, Cu mm Type Back-up 4 2.5 1.5 1 0.75 protection 50 range XTPRP16BC1 Rated with XTPAXCL Current 30 XTPR6P3BC1 n [A] XTPR010BC1 20 XTPR…D 16 XTPR016BC1 Rated XTPR020BC1 short-circuit breaking 10 XTPR025BC1 capacity 6 XTPR016DC1 range XTPR…D XTPR025DC1 XTPR032DC1 16... 25 32 40 50 63 Rated XTPR040DC1 Current XTPR050DC1 n [A] XTPR058DC1 XTPR063DC1 Figure 34-105. Fuseless Installation with XTPR, Back-Up Protection Diagrams Figure 34-104. Protection of PVC Insulated Cables Against Thermal Overload at Short Circuit The table indicates which minimum cable cross-sections are protected by XTPR motor protective circuit breakers up to their rated conditional short circuit current I . q For more information visit: www.eaton.com CA08102001E ... cn cn cc cc Inherently short-circuit proof Inherently short-circuit proof cc rms [kA] cc rms [kA] Inherently short-circuit-proof XTPR…B XTPR…B + XTPAXCL IEC Contactors & Starters 34-145 XT IEC Power Control March 2009 Manual Motor Protectors Time/Current Curve 2h 20 XTPB, XTPR Frame B Characteristics 10 5 The time/current characteristic, the current limiting charac- 2 teristics and the I t characteristics were determined in accor- 2 dance with DIN VDE 0660 and IEC 60 947. 1 40 The tripping characteristic of the inverse-time delayed over- 20 34 load releases (thermal overload releases or “a” releases) for 10 DC and AC with a frequency of 0 to 400 Hz also apply to the 5 time/current characteristic. XTPT 2 The characteristics apply to the cold state. At operating 1 temperature, the tripping times of the thermal releases are reduced to approximately 25%. 200 Under normal operating conditions, all three poles of the 50 device must be loaded. The three main conducting paths must be connected in series in order to protect single-phase 20 or DC loads. 5 With 3-pole loading, the maximum deviation in the tripping time for 3 times the setting current and upwards is ±20% and 2 1.5 2 3 4 6 8 10 15 20 30 thus in accordance with DIN VDE 0165. x Rated Operational Current The tripping characteristics for the instantaneous, electro- magnetic overcurrent releases (short-circuit releases or “n” Figure 34-106. MMP Tripping Characteristics — XTPB, XTPR Frame B releases) are based on the rated current I , which is also the n and XTPT (not for XTPM) maximum value of the setting range for circuit-breakers with adjustable overload releases. If the current is set to a lower 2h value, the tripping current of the “n” release is increased by 20 XTPR Frame D a corresponding factor. 10 The characteristics of the electromagnetic overcurrent 5 releases apply to frequencies of 50/60 Hz. Appropriate 2 correction factors must be used for lower frequencies up to 1 16-2/3 Hz, for higher frequencies up to 400 Hz and for DC. 40 20 Time/current characteristics, current limiting characteristics 10 2 and I t characteristics are available on request. 5 2 1 200 50 20 5 2 1.5 2 3 4 6 8 10 15 20 30 x Rated Operational Current Figure 34-107. MMP Tripping Characteristics — XTPR Frame D CA08102001E For more information visit: www.eaton.com Milli-seconds Seconds Minutes Milli-seconds Seconds Minutes IEC Contactors & Starters 34-146 XT IEC Power Control March 2009 Manual Motor Protectors 32 A 6 10 25 A 10 XTPB XTPR Frame B 20 A 8 8 ^ 2 XTPR Frame B 25 A 16 A i dt XTPM I D XTPM 6 6 10 A/12 A 20 A 2 [kA] [A s] 16 A 6.3 A 4 4 3 10 A 3 4.0 A 2 2 6.3 A 1.5 34 4 10 1 2.5 A 8 0.8 6 0.6 4.0 A 1.6 A 4 0.4 3 0.3 2 0.2 1 A 2.5 A 1.5 3 10 0.1 8 0.08 0.63 A 6 0.06 1.6 A 4 0.04 3 0.03 0.4 A 2 0.02 U = 400 V U = 400 V e e 1.5 0.015 0.25 A 2 1.0 A 10 0.01 1 1.524 3 6 8 10 15 20 3040 6080100 12 1.5 3 4 6 8 10 15 20 3040 6080100 [kA] [kA] cc rms cc rms Figure 34-108. MMP Let-Through Tripping Characteristics — XTPB, XTPR Frame B, XTPT, XTPM 6 100 10 XTPR Frame D XTPR Frame D ^ 2 ID i dt 2 [kA] [A s] 63/58 A 50/40/32 A 5 25 A 10 16 A 63/58 A 50/40/32 A 25 A 4 10 10 16 A 3 10 U = 400 V U = 400 V e e 2 1 10 1 10 100 1 10 100 [kA] [kA] cc rms cc rms Figure 34-109. MMP Let-Through Tripping Characteristics — XTPR Frame D For more information visit: www.eaton.com CA08102001E 2 • cc cc 2 • 1st half-wave 1st half-wave IEC Contactors & Starters 34-147 XT IEC Power Control March 2009 Manual Motor Protectors Manual Motor Protector Short Circuit Ratings Rated uninterrupted current I = Rated operational current I . e u Rated conditional short circuit current I — IEC/EN 60947-4-1. q Rated ultimate short circuit breaking capacity I — IEC/EN 60947-2. cu Rated operational short circuit breaking capacity I — IEC/EN 60947-2. cs Table 34-184. Manual Motor Protector Short Circuit Ratings — Global Use, IEC/EN 60947 34 I 230V 400V 440V 500V 690V u �� �� �� �� �� I I I Fuse I I I Fuse I I I Fuse I I I Fuse I I I Fuse q cu cs q cu cs q cu cs q cu cs q cu cs A kA kA kA A kA kA kA A kA kA kA A kA kA kA A kA kA kA A XTPB with classification Type “1” and Type “2” 0.16 – 1 50 50 50 50 50 50 50 50 50 50 50 50 1.6 50 50 50 50 50 50 50 50 50 50 50 50 2.5 50 50 50 50 50 50 50 50 50 50 50 50 4 50 50 50 50 50 50 50 50 50 50 50 50 6.3 50 50 50 50 50 50 50 50 50 50 50 50 10 50 50 50 50 50 50 50 50 42 42 10 50 12 50 50 10 50 50 50 10 50 15 15 10 50 16 50 50 10 50 50 50 10 50 15 15 10 50 20 50 50 10 50 50 50 10 50 10 10 10 50 25 50 50 10 50 50 50 10 50 10 10 10 50 XTPR…BC1, XTPT, XTPM with classification Type “1” and Type “2” � � � � � � � � � � � � � � � 0.16 – 1 150 150 150 N 150 150 150 N N N N � � � � � � � � � � � � � � � 1.6 150 150 150 N 150 150 150 N N N N � � � � � � � � � � � � 2.5 150 150 150 N 150 150 150 N N N 5 5 5 50 � � � � � � � � � � � � 4 150 150 150 N 150 150 150 N N N 3 3 3 50 � � � � � � � � � 6.3 150 150 150 N 150 150 150 N N 42 42 6 50 3 3 2 50 � � � � � � 10 150 150 150 N 150 150 150 N 42 42 10 50 42 42 6 50 3 3 2 50 12 50 50 10 50 50 50 10 50 15 15 10 50 15 15 6 50 3 3 2 50 16 50 50 10 50 50 50 10 50 15 15 10 50 15 15 6 50 3 3 2 50 20 50 50 10 50 50 50 10 50 15 15 10 50 6 6 6 50 3 3 2 50 25 50 50 10 50 50 50 10 50 10 10 10 50 6 6 6 50 3 3 2 50 32 50 50 10 50 50 50 10 50 10 10 10 50 6 6 6 50 3 3 2 50 XTPR…DC1 with classification Type “1” and Type “2” � � � � 16 150 150 25 N 150 150 25 N 45 45 25 100 15 15 100 8 8 2.5 100 � � � � 25 150 150 25 N 150 150 25 N 45 45 25 100 15 15 100 8 8 2.5 100 32 50 50 25 100 50 50 25 100 45 45 25 100 15 15 100 5 5 2.5 100 40 50 50 25 100 50 50 25 100 45 45 25 100 15 15 100 5 5 2.5 100 50 50 50 25 100 50 50 25 100 45 45 25 100 15 15 100 5 5 2.5 100 58 50 50 25 160 50 50 25 160 45 45 25 160 15 15 160 5 5 2.5 160 63 50 50 25 160 50 50 25 160 45 45 25 160 15 15 160 5 5 2.5 160 XTPR…BC1, XTPT, XTPM with Current Limiter XTPAXCL � � � � � � � � � � � � � � 0.16 – 1 N N N N 20 N � � � � � � � � � � � � � � 1.6 N N N N 20 N � � � � � � � � � � � � 2.5 N N N N 20 20 20 N � � � � � � � � � � � � 4 N N N N 20 20 20 N � � � � � � � � � � � 6.3 N N N 50 N 20 20 20 N � � � � � � � � � � � 10 N N N 20 N 20 20 20 N � � � � � � � � � � � 12 N N N 20 N 5 5 2.5 N � � � � � � � � � � � 16 N N N 20 N 5 5 2.5 N � � � � � � � � � 20 N N N 10 10 10 N 5 5 2.5 N � � � � � � � � � 25 N N N 10 10 10 N 5 5 2.5 N � � � � � � � � � 32 N N N 10 10 10 N 5 5 2.5 N XTPR…BC1, XTPT, XTPM with (2) Current Limiters XTPAXCL � � � � � � � � � � � � � � 0.16 – 1 N N N N 20 N � � � � � � � � � � � � � � 1.6 N N N N 20 N � � � � � � � � � � � � 2.5 N N N N 40 40 20 N � � � � � � � � � � � � 4 N N N N 40 40 20 N � � � � � � � � � � � 6.3 N N N 50 N 20 20 20 N � � � � � � � � � � � 10 N N N 40 N 20 20 20 N � � � � � � � � � � � 12 N N N 40 N 10 10 2.5 N � � � � � � � � � � � 16 N N N 40 N 10 10 2.5 N � � � � � � � � � 20 N N N 20 20 20 N 10 10 2.5 N � � � � � � � � � 25 N N N 20 20 20 N 10 10 2.5 N � � � � � � � � � 32 N N N 20 20 20 N 10 10 2.5 N � No upstream protective device required, as it is the auto-protected range (100/150 kA — Frame B, 150 kA — Frame D). � N = Not required. � XTPR…BC1, XTPT, XTPM — Required back-up fuse if the short circuit current exceeds the rated conditional short circuit current (I > I ); cc q XTPB, XTPR...DC1 — Fuse (A gG/gL) for enhancing the switching capacity of the motor protective circuit breaker to 100 kA. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-148 XT IEC Power Control March 2009 Manual Motor Protectors Table 34-185. Ratings for Group Motor Applications — UL 508 / CSA C22.2 No. 14 Catalog Rated FLA Short Maximum Protective Device for UL/CSA Group Protection Number Uninterrupted Adjustment Circuit Max. RMS Sym Current — Maximum Fuse Circuit Breaker Current — Range / Release — 600V (kA) Rating (A) Max (A) I (Amps) Overload I (Amps) u rm w/Current w/Current w/Current Release — Limiter — Limiter — Limiter — I (Amps) r XTPAXCL XTPAXCL XTPAXCL 34 XTPB — Frame B, Manual Motor Protector with Thermal and Magnetic Trip XTPBP16BC1 0.16 0.1 – 0.16 2.2 50 — 600 — 600 — XTPBP25BC1 0.25 0.16 – 0.25 3.5 50 — 600 — 600 — XTPBP40BC1 0.4 0.25 – 0.4 5.6 50 — 600 — 600 — XTPBP63BC1 0.63 0.4 – 0.63 8.8 50 — 600 — 600 — XTPB001BC1 1 0.63 – 1 14 50 — 600 — 600 — XTPB1P6BC1 1.6 1 – 1.6 22 50 — 600 — 600 — XTPB2P5BC1 2.5 1.6 – 2.5 35 50 — 600 — 600 — XTPB004BC1 4 2.5 – 4 56 50 — 600 — 600 — XTPB6P3BC1 6.3 4 – 6.3 88 50 — 600 — 600 — � XTPB010BC1 10 6.3 – 10 140 10 50 150 600 125 600 � XTPB012BC1 12 8 – 12 168 10 50 150 600 125 600 � � � � �� � XTPB016BC1 16 10 – 16 224 10 50 150 600 125 600 � � � � � � � XTPB020BC1 20 16 – 20 280 10 18 150 600 125 600 � � � � � � � XTPB025BC1 25 20 – 25 350 10 18 150 600 125 600 XTPR — Frame B (all Screw and Spring Cage terminal options), Manual Motor Protector with Thermal and Magnetic Trip XTPRP16BC1 0.16 0.1 – 0.16 2.2 50 — 600 — 600 — XTPRP25BC1 0.25 0.16 – 0.25 3.5 50 — 600 — 600 — XTPRP40BC1 0.4 0.25 – 0.4 5.6 50 — 600 — 600 — XTPRP63BC1 0.63 0.4 – 0.63 8.8 50 — 600 — 600 — XTPR001BC1 1 0.63 – 1 14 50 — 600 — 600 — XTPR1P6BC1 1.6 1 – 1.6 22 50 — 600 — 600 — XTPR2P5BC1 2.5 1.6 – 2.5 35 50 — 600 — 600 — XTPR004BC1 4 2.5 – 4 56 50 — 600 — 600 — XTPR6P3BC1 6.3 4 – 6.3 88 50 — 600 — 600 — � XTPR010BC1 10 6.3 – 10 140 10 50 150 600 125 600 XTPR012BC1 12 8 – 12 168 10 50 150 600 125 600 � XTPR016BC1 16 10 – 16 224 10 50 150 600 125 600 XTPR020BC1 20 16 – 20 280 10 18 150 600 125 600 XTPR025BC1 25 20 – 25 350 10 18 150 600 125 600 XTPR032BC1 32 25 – 32 448 10 18 150 600 125 600 XTPR — Frame D, Manual Motor Protector with Thermal and Magnetic Trip XTPR016DC1 16 10 – 16 224 10 — 600 — 600 — XTPR025DC1 25 16 – 25 350 10 — 600 — 600 — XTPR032DC1 32 25 – 32 448 10 — 600 — 600 — XTPR040DC1 40 32 – 40 560 10 — 600 — 600 — � � � XTPR050DC1 50 40 – 50 700 10 — 600 — 600 — � � � XTPR058DC1 58 50 – 58 812 10 — 600 — 600 — � � � XTPR063DC1 65 55 – 63 882 10 — 600 — 600 — XTPT — Frame D, Manual Motor Protector with Thermal and Magnetic Trip XTPTP16BC1 0.16 0.1 – 0.16 2.4 50 — 600 — 600 — XTPTP25BC1 0.25 0.16 – 0.25 4.25 50 — 600 — 600 — XTPTP40BC1 0.4 0.25 – 0.4 6.8 50 — 600 — 600 — XTPTP63BC1 0.63 0.4 – 0.63 12 50 — 600 — 600 — XTPT001BC1 1 0.63 – 1 20 50 — 600 — 600 — XTPT1P6BC1 1.6 1 – 1.6 32 50 — 600 — 600 — XTPT2P5BC1 2.5 1.6 – 2.5 50 50 — 600 — 600 — XTPT004BC1 4 2.5 – 4 84 50 — 600 — 600 — XTPT6P3BC1 6.3 4 – 6.3 141 50 — 600 — 600 — � XTPT010BC1 10 6.3 – 10 224 10 50 150 600 125 600 XTPT012BC1 12 8 – 12 224 10 50 150 600 125 600 XTPT016BC1 16 10 – 16 358 10 50 150 600 125 600 XTPT020BC1 20 16 – 20 380 10 18 150 600 125 600 XTPT025BC1 25 20 – 25 420 10 18 150 600 125 600 � Rating is pending UL approval. Contact Eaton for availability. � 22kA 600V AC � IEC/EN 60947-4-1 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-149 XT IEC Power Control March 2009 Manual Motor Protectors Table 34-186. UL 508 Type E Ratings Manual Motor Line Side FLA Adjustment Short-Circuit UL508 Type E Application Range / Overload Release — I Protector — Adapter rm Max. RMS Symmetrical Short-Circuit Maximum Upstream Release — I (Amps) Screw Terminals r � Ratings (kA) Protective Device (A) (Amps) Catalog Catalog 240V 480/277V 600/347V Maximum Fuse Maximum 600V Circuit Breaker Number Number 600V XTPR Frame B + XTPAXLSA 34 XTPRP16BB1 XTPAXLSA 0.1 – 0.16 2.2 50 50 50 Not Required Not Required XTPRP16BC1 XTPAXLSA 0.16 – 0.25 3.5 50 50 50 Not Required Not Required XTPRP25BC1 XTPAXLSA 0.25 – 0.4 5.6 50 50 50 Not Required Not Required XTPRP40BC1 XTPAXLSA 0.4 – 0.63 8.82 50 50 50 Not Required Not Required XTPRP63BC1 XTPAXLSA 0.63 – 1 14 50 50 50 Not Required Not Required XTPR001BC1 XTPAXLSA 1 – 1.6 22.4 50 50 50 Not Required Not Required XTPR1P6BC1 XTPAXLSA 1.6 – 2.5 35 50 50 50 Not Required Not Required XTPR2P5BC1 XTPAXLSA 2.5 – 4 56 50 50 50 Not Required Not Required XTPR004BC1 XTPAXLSA 4 – 6.3 88.2 50 50 50 Not Required Not Required XTPR6P3BC1 XTPAXLSA 6.3 – 10 140 50 50 50 Not Required Not Required XTPR010BC1 XTPAXLSA 8 – 12 168 42 42 — Not Required Not Required XTPR012BC1 XTPAXLSA 10 – 16 224 42 42 — Not Required Not Required XTPR016BC1 XTPAXLSA 10 – 16 224 18 18 — Not Required Not Required XTPR020BC1 XTPAXLSA 16 – 20 280 18 18 — Not Required Not Required XTPR025BC1 XTPAXLSA 20 – 25 350 18 18 — Not Required Not Required XTPR032BC1 XTPAXLSA 25 – 32 448 18 18 — Not Required Not Required XTPR Frame D + XTPAXLSAD XTPR016DC1 XTPAXLSAD 10 – 16 224 50 50 50 Not Required Not Required XTPR025DC1 XTPAXLSAD 16 – 25 350 50 50 50 Not Required Not Required XTPR032DC1 XTPAXLSAD 25 – 32 448 50 50 50 Not Required Not Required XTPR040DC1 XTPAXLSAD 32 – 40 560 50 50 50 Not Required Not Required XTPR050DC1 XTPAXLSAD 40 – 50 700 65 65 — Not Required Not Required XTPR058DC1 XTPAXLSAD 50 – 58 812 65 65 — Not Required Not Required XTPR063DC1 XTPAXLSAD 55 – 65 882 65 65 — Not Required Not Required � For UL 508 Type E applications, the Manual Motor Protector assembly does not require a dedicated upstream protective device in the panel, thus a maximum rating is not required. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-150 XT IEC Power Control March 2009 Manual Motor Protectors Dimensions 93 _ _ XTPAXFA XTPAXFA _ XTPAXFA [3.66] 93 45 45 34 [3.66] [1.77] [1.77] 45 5.5 44 45 50 _ XTPAXFA [1.77] [.22] [1.73] [1.77] [1.97] 74 [2.91] 88 [3.46] 85 [3.35] 94 [3.70] Figure 34-110. Manual Motor Protectors — XTPB Figure 34-111. Manual Motor Protectors, Manual Transformer (Approximate Dimensions in mm [in]) Protectors — XTPR…B, XTPT and XTPM (Approximate Dimensions in mm [in]) 4 [.16] 65 _ XTPAXFA [2.56] 130 125 45 [5.12] [4.92] [1.77] 140 [5.57] _ XTPAXFA 30 7.5 [.30] [1.18] 55 [2.17] 118 [4.65] 127 [5.00] 145 [5.71] 171 [6.73] Figure 34-112. Manual Motor Protector — XTPR…DC1 (Approximate Dimensions in mm [in]) 45 80 [3.15] [1.77] 28 [1.10] * XTPAXFAEM20 93 45 55 [3.66] [1.77] [2.17] 90 73 93 [3.54] [2.87] [3.66] 45 50 XTPAXFAEM20 7.5 44 7.5 [1.77] [1.97] [.30] [1.73] [.30] 68 [2.68] 49.5 70 86 [3.39] * IEC/EN 60715 DIN Rail [1.95] [2.76] Figure 34-113. Current Limiter — XTPAXCL (Approximate Figure 34-114. MMPs with Early-Make Auxiliary Contacts — Dimensions in mm [in]) XTPR…BC1 + XTPAXFAEM20 (Approximate Dimensions in mm [in]) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-151 XT IEC Power Control March 2009 Manual Motor Protectors 261 [10.28] (207 [8.15], 153 [6.02], 99 [3.90]) 45 36 90 [1.77] [1.42] [3.54] 27 [1.06] 54 [2.13] 34 9 26 [.35] [1.02] Overlapping Mounting to Extend the Three-Phase 68 [2.68] Commoning Link Figure 34-115. Standard Auxiliary Contact — XTPAXSA… Figure 34-119. Three-Phase Commoning Link — XTPAXCLKB5, (Approximate Dimensions in mm [in]) XTPAXCLKB4, XTPAXCLKB3, and XTPAXCLKB2 (Approximate Dimensions in mm [in]) 234 [9.21] (108 [4.25]) 45 36 90 [1.77] [1.42] [3.54] 27 [1.06] 63 [2.48] 9 26 [.35] [1.02] Figure 34-120. Three-Phase Commoning Link — XTPAXCLKC4, 68 [2.68] XTPAXCLKC2 (Approximate Dimensions in mm [in]) Figure 34-116. Trip Indicating Auxiliary Contact — XTPAXSATR… (Approximate Dimensions in mm [in]) 56 ≤ [2.20] 7.5 31 [.30] [1.22] XTPAXLSA 73 48 [2.87] 45 36 90 [1.89] [1.77] [1.42] [3.54] 41 ≤ [1.61] XTPAXIT 18 49 [.71] [1.93] 68 [2.68] Figure 34-117. Undervoltage / Shunt Release — XTPAXUVR…, XTPAXSR… (Approximate Dimensions in mm [in]) Figure 34-121. Incoming Terminal, Line Side Adapter — XTPAXIT, XTPAXLSA (Approximate Dimensions in mm [in]) 180 [7.09] (90 [3.54]) 27 [1.06] 45 [1.77] Figure 34-118. Three-Phase Commoning Link — XTPAXCLKA4, XTPAXCLKA2 (Approximate Dimensions in mm [in]) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-152 XT IEC Power Control March 2009 Manual Motor Protectors 36 36 [1.42] [1.42] 33 260 [10.24] 14 33 [1.30] 205 [8.07] 14 [.55] [1.30] [.55] XTPAXCLKA4D XTPAXCLKC4D 34 36 36 [1.42] [1.42] 33 33 151 [5.94] 14 115 [4.53] 14 [1.30] [1.30] [.55] [.55] XTPAXCLKA3D XTPAXCLKC2D Figure 34-124. Three-Phase Commoning Link — XTPAXCLKC4D and XTPAXCLKC2D 36 (Approximate Dimensions in mm [in]) [1.42] 33 98 [3.86] 14 [1.30] [.55] XTPAXCLKA2D Figure 34-122. Three-Phase Commoning Link — XTPAXCLKA4D, XTPAXCLKA3D and XTPAXCLKA2D (Approximate Dimensions in mm [in]) 36 [1.42] 33 232 [9.13] 14 [1.30] [.55] XTPAXCLKB4D 36 [1.42] 33 170 [6.69] 14 [1.30] [.55] XTPAXCLKB3D 36 [1.42] 33 117 [4.6] 14 [1.30] [.55] XTPAXCLKB2D Figure 34-123. Three-Phase Commoning Link — XTPAXCLKB4D, XTPAXCLKB3D and XTPAXCLKB2D (Approximate Dimensions in mm [in]) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-153 XT IEC Power Control March 2009 Manual Motor Protectors 158 [6.22] 158 [6.22] 34 80 [3.15] 116.5 [4.59] 80 [3.15] 116.5 [4.59] 177.2 [6.98] XTPBXENCS40 XTPBXENAS41 XTPBXENCSEK65 XTPBXENASEK65 XTPBXENCS65 XTPBXENAS65 XTPBXENCSES65 XTPBXENASES65 158 [6.22] 80 [3.15] 116.5 [4.59] 129.5 [5.10] XTPBXENCSLE65 XTPBXENASLE65 XTPBXENCSLO65 XTPBXENASO065 Figure 34-125. Insulated Enclosures for Surface Mounting of XTPB Manual Motor Protectors (Approximate Dimensions in mm [in]) 69 69 [2.72] [2.72] 129 129 [5.08] [5.08] 90.2 90.2 93 [3.66] 93 [3.66] [3.55] [3.55] 115.2 [4.54] 115.2 [4.54] 175.9 [6.93] XTPBXENCF40 XTPBXENCF55 XTPBXENCFEK55 XTPBXENCFES55 69 [2.72] 129 [5.08] 90.2 93 [3.66] [3.55] 115.2 [4.54] XTPBXENCFLE55 XTPBXENCFLO55 Figure 34-126. Insulated Enclosures for Flush Mounting of XTPB Manual Motor Protectors (Approximate Dimensions in mm [in]) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-154 XT IEC Power Control March 2009 Manual Motor Protectors Drilling Dimensions 4.5 [.18] 158 70 [6.22] [2.76] 153 158 34 [6.02] [6.22] 90 [3.54] 80 [3.15] 100 [3.94] 4.5 80 [3.15] 97.5 [3.84] 8 XTPAXENCS40 [.18] 125.5 [4.94] [.31] XTPAXENCS55B XTPAXENCSEM55B XTPAXENCS55RY XTPAXENCSEM55RY 98 [3.86] 30 [1.18] 30 SVB-PKZ0-CI Drilling Dimensions [1.18] 4.5 44 28 [.18] [1.73] 97.5 [3.84] [1 . 10] 33 [1.30] 55 158 153 [2.17] [6.22] [6.02] 4.5 80 [3.15] 8 [.18] XTPAXENCS55_ + XTPAXPL1 [.31] XTPAXENCSEM55_ + XTPAXPL1 Drilling Dimensions M4 XTPAXENCS65B XTPAXENCS65RY XTPAXENCSEM65B 181 160 [7.13] [6.30] XTPAXENCSEM65RY XTPAXENAS55B 181 160 171 XTPAXENAS55RY [7.13] [6.30] [6.73] XTPAXENASEM55B XTPAXENASEM55RY XTPAXENCSH65B 47.5 100 [1.87] XTPAXENCSH65RY [3.94] XTPAXENCSEMH65B 104 [4.09] XTPAXENCSEMH65RY 100 47.5 M4 [3.94] [1.87] XTPAXENCSH41 XTPAXENAS41 103 [4.06] XTPAXENCS41 130 [5.12] 98 [3.86] 30 [1.18] 30 SVB-PKZ0-CI [1. 18] Drilling Dimensions 44 28 M4 114 [4.49] [1.73] [1. 10] 33 [1.30] 171 181 160 55 [6.73] [7.13] [6.30] [2.17] M4 97 [3.82] XTPAXENCS65_ + XTPAXPL1 XTPAXENCSEM65_ + XTPAXPL1 Figure 34-127. Insulated Enclosures for Surface Mounting of XTPR...B Manual Motor Protectors (Approximate Dimensions in mm [in]) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-155 XT IEC Power Control March 2009 Manual Motor Protectors 69 [2.72] 4 [.16] R 129 55 116 – 118 [5.08] [2.17] [4.57 – 4.64] 34 85 [3.35] 80 [3.15] 96 [3.78] 70 – 72 [2.76 – 2.83] 124 [4.88] XTPAXENCF40 Mounting Cutout XTPAXENCF... XTPAXENCF55B XTPAXENCF55RY 98 [3.86] 30 [1.18] 58 30 [2.28] [1.18] 28 [1.10] 21 55 [.83] 129 [2.17] [5.08] 80 [3.15] 85 96 [3.78] [3.35] 124 [4.88] XTPAXENCF55_ + XTPAXPL3 Figure 34-128. Insulated Enclosures for Flush Mounting of XTPR...B Manual Motor Protectors (Approximate Dimensions in mm [in]) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-156 XT IEC Power Control March 2009 Manual Motor Protectors 98 [3.86] 3 [.12] 32 [1.26] SVB-PKZ4-CI 34 240 [9.45] 72 [2.83] 160 [6.30] 134 [5.28] 181 [7.13] 197 [7.76] XTPAXENCSD65B XTPAXENCSD65_ + XTPAXPL2 XTPAXENCSD65RY Drilling Dimensions 5.6 [.22] Dia. 72 [2.83] 240 193 [9.45] [7.60] 160 [6.30] 186 [7.32] 28 [1.10] 142 [5.60] 30 [1.18] XTPAXENCSD65 Figure 34-129. Insulated Enclosures for Surface Mounting of XTPR...D Manual Motor Protectors (Approximate Dimensions in mm [in]) 43 [1.69] Dia. 64 48 [2.52] [1.89] 64 48 [2.52] [1.89] 62 [2.44] 19.5 [.77] Mounting Depth: 100 – 240 [3.94 – 9.45] from the top edge of At least 100 [3.94] the mounting rail to the up to Cover Hinge front edge of the panel door/cover Figure 34-130. Rotary Handle Mechanism — XTPAXRHM… (Approximate Dimensions in mm [in]) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-157 XT IEC Power Control March 2009 Combination Motor Controllers For actual UL 508 Type E/F applications Contents Application Description (out-of-panel upstream feeder Short- Description Page Circuit Protective Device [SCPD] only), The XT IEC Non-reversing and a maximum 240V Delta is permitted or Reversing Manual and Combination Standards and 480Y/277V and 600Y/347V slash rated Motor Controllers can be used in the Certifications . . . . . . . . . . . . 34-158 Wye systems. following applications: Catalog Number For Manual “At Motor” Disconnect Selection . . . . . . . . . . . . . . . . 34-159 XTSC and XTSR applications, a maximum 240V Delta is 34 Product Selection . . . . . . . . . . 34-160 ■ Manual Motor Controller for Single permitted or 480Y/277V and 600Y/347V Accessories . . . . . . . . . . . . . . . 34-162 and Multi Motor Panels — The pre- slash rated Wye systems. assembled XT Manual Motor Con- Technical Data and trollers (MMC) combine a Manual Specifications . . . . . . . . . . . . 34-165 Features Motor Protector, a Wiring Connector Dimensions . . . . . . . . . . . . . . . 34-169 Link and IEC Contactor. MMCs can ■ ON/OFF rotary handle with lockout Reference Data . . . . . . . . . . . . 34-210 also be field installed with separate provision MMP, WCL and Contactor(s). An IEC ■ Visible trip indication magnetic contactor has been added ■ Test trip function to allow for remote operation of the motor circuit. ■ Motor applications from 0.10A to 63A XTFC and XTFR ■ Class 10 overload protection ■ Combination Motor Controller (UL ■ Built-in heater and magnetic trip 508, Type F), for Single and Multi elements to protect the motor Motor Panels — The preassembled ■ Phase loss sensitivity IEC Combination Motor Controllers ■ Type 2 coordination combine a Line Side Adapter, Man- ■ Ambient compensated up to ual Motor Protector, Wiring Connec- 55°C [140°F] tor Link and IEC Contactor. The ■ Control inputs located at front of XTPR Manual Motor Protectors are UL listed as UL 508, Type E Self- starter for easy access and wiring Protected Manual Combination ■ Wide range of coils Starters. This UL listing allows these ■ DIN Rail mount — XTSC…BB_ devices to be used in motor circuits ■ Mounting plates — XTSC…BC_, without having to add separate XTSC…D motor controllers branch short circuit protection. An XT Combination Motor Controller ■ Adjustment dial for setting IEC magnetic contactor has been and Manual Motor Controller motor FLA added to allow for remote operation of the motor circuit. ■ Short circuit trip at 14 times the maximum setting of the FLA Product Description ■ Group Motor Installations — Since adjustment dial the Manual Motor Protectors ® The new Cutler-Hammer XT IEC (Manual Combination Starters) ■ UL 508 Type F CMC High Fault Open Non-reversing and Reversing are UL listed for Group Motor Short Circuit Ratings: Refer to Manual Motor Controllers from Installations, the IEC Manual Motor Table 34-198. Eaton’s electrical business combine a Controllers provide a compact, ■ 1NO-1NC Auxiliary Contact Manual Motor Protector with an IEC assembled package for Group as standard on Manual Motor Contactor(s) to provide a complete Motor Installations up to 600V. Controller and Combination Motor motor protection solution by combin- Controller For Group Installations (in-panel ing motor disconnect function, thermal SCPD) applying the traditional 1/3 tap overload protection, magnetic short rule, the Manual Motor Protectors and circuit protection and remote control Combination Motor Controllers may operation in one compact, assembled be used on 480V Delta systems along unit. These assembled Manual Motor with 480Y/277V and 600Y/347V slash Controllers cover motors with FLA rated Wye systems. For Group Installa- ratings from 0.10A to 63A. tions, applying the more recent 1/10 The UL 508 Type F labeled Combination tap conductor rule, a maximum 240V Motor Controller (CMC) includes a Line Delta is permitted or 480Y/277V and Side Adapter (LSA). These assembled 600Y/347V slash rated Wye systems. Combination Motor Controllers cover motors with FLA ratings from 0.10A to 52A. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-158 XT IEC Power Control March 2009 Combination Motor Controllers Table 34-187. MMC and CMC Applications Standards and Certifications UL 508 Type F Combination Motor XT IEC Manual & Combination Motor Controllers Controller ■ IEC Type 2 Approved per IEC 60947-4-1 Group Installation UL 508 Type F Combination Motor Controller ■ UL Listed File No. E245398 � Using the in-panel Main Only Upstream Feeder SCPD required with factory 34 � � � ■ CE Mark SCPD and an MMC assembled LSA; no dedicated in-panel Main SCPD without a factory for CMC. assembled LSA. Line Side Adapter (LSA) Line Side Adapter (LSA) Note: For Type 2 Coordination of MMCs, Not required Required — Factory see Tables 34-249 through 34-251 on Pages Assembled 34-210 and 34-211. Manual Motor Controller Combination Motor Controller Protection in Different Controller XTSC / XTSR XTFC / XTFR Types � SCPD = Short Circuit Protective Device (Circuit Breaker, Fuses). A UL 508 Type E Self-protected Manual � MMC = Manual Motor Controller Combination Starter/Motor Controller Reference: Technical Paper AP03402001E. consists of a single device having inte- Note: Line Side Adapters are not required for non-U.S. applications. Most countries outside gral short circuit protection, a main set of the U.S. classify the MMP as a thermal magnetic circuit breaker. of contacts, motor overload protec- tion, and may also include a UL listed Line Side Adapter (see Table 34-187). This type of controller is a legitimate short circuit protective device and dis- connect means for the downstream motor. It does require an upstream feeder short circuit protective device, but does not require a dedicated branch circuit protection or a discon- nect means if used with a Line Side Adapter. A UL 508 Type E rating means that the unit clears a fault and does not experience any welding of the power poles. A UL 508 Type E self-protected manual motor controller will remain fully functional should a short circuit within its ratings occur. E.g. XTPR. An XT UL 508 Type F Self-protected Combination Motor Controller consists of a UL Listed Type E Self-protected Manual Combination Starter/Motor Controller, a UL Listed Contactor, and a UL Listed Line Side Adapter (see Table 34-187). While the UL 508 Type E self-protected manual motor protector of this combination motor controller device is a legitimate short circuit protective device and disconnect means for the downstream motor, the contactor is not “self-protected.” E.g. XTFC, XTFR. In addition, as a complete assembly or modular components, the device should have Type 2 Coordination certi- fication. Type 2 Coordination means the Starter or the Controller must exhibit little or no damage following a major short circuit fault and should be able to be returned to proper service without replacing any parts. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-159 XT IEC Power Control March 2009 Combination Motor Controllers Catalog Number Selection Table 34-188. Combination Motor Controllers — Catalog Numbering System X T S C 0 1 2 B B A Design Coil Voltage 34 XT = XT IEC Power Control A = 110V 50 Hz, 120V 60 Hz B = 220V 50 Hz, 240V 60 Hz C = 415V 50 Hz, 480V 60 Hz Type D = 550V 50 Hz, 600V 60 Hz E = 208V 50 Hz SC = Manual Motor Controller — FVNR F = 230V 50 Hz SR = Manual Motor Controller — FVR G = 190V 50 Hz, 220V 60 Hz FC = Combination Motor Controller, UL 508 Type F — FVNR H = 240V 50 Hz, 277V 60 Hz FR = Combination Motor Controller, UL 508 Type F — FVR L = 380V 50 Hz, 440V 60 Hz N = 400V 50 Hz P = 380V 60 Hz Rated Current of MMP R = 12V 50/60 Hz B-Frame D-Frame T = 24V 50/60 Hz U = 24V 50 Hz P16 = 0.16A 016 = 16A W = 42V 50 Hz, 48V 60 Hz P25 = 0.25A 025 = 25A Y = 48V 50 Hz P40 = 0.40A 032 = 32A AD = 120V DC P63 = 0.63A 040 = 40A BD = 220V DC 001 = 1A 050 = 50A RD = 12V DC 1P6 = 1.6A 058 = 58A TD = 24V DC 2P5 = 2.5A 063 = 65A WD = 48V DC 004 = 4A 6P3 = 6.3A 010 = 10A Frame Size — Contactor 012 = 12A 016 = 16A B = 45 mm, 7 to 15A 020 = 20A C = 45 mm, 18 to 32A 025 = 25A D = 55 mm, 40 to 65A 032 = 32A Frame Size — MMP B = 45 mm, 0.1 to 32A D = 55 mm, 16 to 63A XTSC FVNR XTSC FVNR XTSC FVNR XTSC FVNR Frame B MMP Frame B MMP Frame D MMP Frame D MMP & Frame B Contactor & Frame C Contactor & Frame C Contactor & Frame D Contactor XTSR FVR XTSR FVR XTSR FVR XTSR FVR Frame B MMP Frame B MMP Frame D MMP Frame D MMP & (2) Frame B Contactors & (2) Frame C Contactors & (2) Frame C Contactors & (2) Frame D Contactors CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-160 XT IEC Power Control March 2009 Combination Motor Controllers Product Selection Table 34-189. XTSC and XTSR Manual Motor Controllers (MMC) / Starter Combinations Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor � � FLA Short- Maximum Motor Ratings — P Assembled Manual Motor Controller Adjustment Circuit Maximum Motor kW Rating Maximum hp Rating — P (hp) Range / Release — AC-3 — P (kW) Overload I rm Three-Phase Three-Phase Non-reversing Reversing Release — I (Amps) r 34 220 – 380 – 500V 660 – 200V 240V 480V 600V Catalog Price Price Catalog Price Price (Amps) 240V 415V 690V Number U.S. $ U.S. $ Number U.S. $ U.S. $ AC Coil DC Coil AC Coil DC Coil Frame B MMP + Frame B Contactor � � 0.1 – 0.16 3.2 — — — 0.06 1/2 1/2 XTSCP16BB_ XTSRP16BB_ � � 0.16 – 0.25 3.5 — 0.06 0.06 0.12 1/2 1/2 XTSCP25BB_ XTSRP25BB_ � � 0.25 – 0.4 5.6 0.06 0.09 0.12 0.18 1/2 1/2 XTSCP40BB_ XTSRP40BB_ � � 0.4 – 0.63 8.82 0.09 0.18 0.25 0.25 1/2 1/2 XTSCP63BB_ XTSRP63BB_ � � 0.63 – 1 14 0.12 0.25 0.37 0.55 1/2 1/2 XTSC001BB_ XTSR001BB_ � � 1 – 1.6 22.4 0.25 0.55 0.75 1.1 3/4 1 XTSC1P6BB_ XTSR1P6BB_ 1.6 – 2.5 35 0.37 0.75 1.1 1.5 1/2 1/2 1 1-1/2 XTSC2P5BB_ XTSR2P5BB_ 2.5 – 4 56 0.75 1.5 2.2 3 1 1 2 3 XTSC004BB_ XTSR004BB_ 4 – 6.3 88.2 1.1 2.2 3 4 1-1/2 1-1/2 3 5 XTSC6P3BB_ XTSR6P3BB_ 6.3 – 10 140 2.2 4 4 7.5 3 3 7-1/2 10 XTSC010BB_ XTSR010BB_ 8 – 12 168 3 5.5 5.5 11 3 3 7-1/2 10 XTSC012BB_ XTSR012BB_ 10 – 16 224 4 7.5 9 12.5 3 3 10 10 XTSC016BB_ — Frame B MMP + Frame C Contactor 10 – 16 224 4 7.5 9 12.5 3 3 10 10 XTSC016BC_ XTSR016BC_ 16 – 20 280 5.5 9 12.5 15 5 5 10 15 XTSC020BC_ XTSR020BC_ 20 – 25 350 5.5 11 15 22 5 7-1/2 15 20 XTSC025BC_ XTSR025BC_ 25 – 32 448 7.5 15 22 30 7-1/2 10 20 25 XTSC032BC_ XTSR032BC_ Frame D MMP + Frame C Contactor 10 – 16 224 4 7.5 9 12.5 3 5 10 15 XTSC016DC_ XTSR016DC_ 16 – 25 350 5.5 12.5 12.5 22 7-1/2 7-1/2 20 25 XTSC025DC_ XTSR025DC_ 25 – 32 448 7.5 15 17.5 22 10 10 25 30 XTSC032DC_ XTSR032DC_ Frame D MMP + Frame D Contactor 32 – 40 560 11 20 22 30 10 — 30 30 XTSC040DD_ XTSR040DD_ 40 – 50 700 14 25 30 45 15 15 30 40 XTSC050DD_ XTSR050DD_ 50 – 58 812 17 30 37 55 — — 40 — XTSC058DD_ XTSR058DD_ 55 – 65 882 18.5 34 37 55 — — 40 — XTSC063DD_ XTSR063DD_ � Select Manual Motor Protectors by full load amperes. Maximum Motor Ratings (kW, hp) are for reference only. For additional voltages not listed, see Table 34-194 on Page 34-165. � In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1). � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-191 on Page 34-162. Notes: The assembled Manual Motor Controller (MMC) consists of an XTPR Manual Motor Protector (MMP) and an XTCE contactor. For Frame B MMP + Frame B Contactor assem- blies, the XTSC and XTSR can be mounted directly on DIN rail without an adapter. The contactors are supported mechanically with a mechanical connection element (included in XTPAXTPCB, XTPAXRPCRB). For 16A and above, the assembly is mounted via a DIN Rail Adapter Plate (XTPAXTPCPC, XTPAXTPCPD) and the electrical connection M M is made with electrical contact modules 3 ~ 3 ~ (XTPAXECMC, XTPAXECMD), both included in XTPAXTPCC and XTPAXTPCD. For detailed component lists, see Table 34-195, Page 34-166. Figure 34-131. XTSC Manual Motor Controller Figure 34-132. XTSR Manual Motor Controller Service Factor Settings: Setting I of current r scale in dependence of load factor: SF = 1.15 ➔ I = 1 x I r n mot SF = 1 ➔ I = 0.9 x I r n mot Single-phasing sensitivity to IEC/ EN 60947-4-1, VDE 0660 Part 102. Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-130 Technical Data . . . . . . . . . . . . . . . . . . Page 34-165 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-161 XT IEC Power Control March 2009 Combination Motor Controllers Table 34-190. XTFC and XTFR Combination Motor Controllers (CMC), UL508 Type F Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor + Required Line Side Adapter � � FLA Short- Maximum Motor Ratings Assembled Combination Motor Controller Adjustment Circuit Maximum Motor kW Rating Maximum hp Rating — P (hp) Range / Release — AC-3 — P (kW) Overload I rm Three-Phase Three-Phase Non-reversing Reversing Release — I (Amps) r 220 – 380 – 500V 660 – 200V 240V 480V 600V Catalog Price Price Catalog Price Price (Amps) 240V 415V 690V Number U.S. $ U.S. $ Number U.S. $ U.S. $ 34 AC Coil DC Coil AC Coil DC Coil Frame B MMP + Frame B Contactor � � 0.1 – 0.16 2.2 — — — 0.06 1/2 1/2 XTFCP16BB_ XTFRP16BB_ � � 0.16 – 0.25 3.5 — 0.06 0.06 0.12 1/2 1/2 XTFCP25BB_ XTFRP25BB_ � � 0.25 – 0.4 5.6 0.06 0.09 0.12 0.18 1/2 1/2 XTFCP40BB_ XTFRP40BB_ � � 0.4 – 0.63 8.82 0.09 0.18 0.25 0.25 1/2 1/2 XTFCP63BB_ XTFRP63BB_ � � 0.63 – 1 14 0.12 0.25 0.37 0.55 1/2 1/2 XTFC001BB_ XTFR001BB_ � � 1 – 1.6 22.4 0.25 0.55 0.75 1.1 3/4 1 XTFC1P6BB_ XTFR1P6BB_ 1.6 – 2.5 35 0.37 0.75 1.1 1.5 1/2 1/2 1 1-1/2 XTFC2P5BB_ XTFR2P5BB_ 2.5 – 4 56 0.75 1.5 2.2 3 1 1 2 3 XTFC004BB_ XTFR004BB_ 4 – 6.3 88.2 1.1 2.2 3 4 1-1/2 1-1/2 3 5 XTFC6P3BB_ XTFR6P3BB_ 6.3 – 10 140 2.2 4 4 7.5 3 3 7-1/2 10 XTFC010BB_ XTFR010BB_ 8 – 12 168 3 5.5 5.5 11 3 3 7-1/2 — XTFC012BB_ XTFR012BB_ 10 – 16 224 4 7.5 9 12.5 3 5 10 — XTFC016BB_ — Frame B MMP + Frame C Contactor 10 – 16 224 4 7.5 9 12.5 3 5 10 — XTFC016BC_ XTFR016BC_ 16 – 20 280 5.5 9 12.5 15 5 5 — — XTFC020BC_ XTFR020BC_ 20 – 25 350 5.5 11 15 22 5 7-1/2 15 — XTFC025BC_ XTFR025BC_ 25 – 32 448 7.5 15 22 30 7-1/2 10 20 — XTFC032BC_ XTFR032BC_ Frame D MMP + Frame C Contactor 10 – 16 224 4 7.5 9 12.5 3 5 10 10 XTFC016DC_ XTFR016DC_ 16 – 25 350 5.5 12.5 12.5 22 7-1/2 7-1/2 20 25 XTFC025DC_ XTFR025DC_ 25 – 32 448 7.5 15 17.5 22 10 10 25 30 XTFC032DC_ XTFR032DC_ Frame D MMP + Frame D Contactor 32 – 40 560 11 20 22 30 10 10 30 40 XTFC040DD_ XTFR040DD_ 40 – 50 700 14 25 30 45 10 15 30 — XTFC050DD_ XTFR050DD_ 50 – 58 812 17 30 37 55 15 15 40 — XTFC058DD_ XTFR058DD_ 55 – 65 882 18.5 34 37 55 15 15 40 — XTFC063DD_ XTFR063DD_ � Select Combination Motor Controllers by full load amperes. Maximum Motor Ratings (kW, hp) are for reference only. For additional voltages not listed, see Table 34-194 on Page 34-165. � In this range, calculate motor rating according to rated current. Specified values to NEC 430.6(A)(1). � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-191 on Page 34-162. Notes: The assembled Combination Motor Control- ler (CMC) consists of an XTPR Manual Motor Protector (MMP) and an XTCE con- tactor and a required Line Side Adapter. For Frame B MMP + Frame B Contactor assem- blies, the XTFC and XTFR can be mounted directly on DIN rail without an adapter. The contactors are supported mechanically with a mechanical connection element (included in XTPAXTPCB, XTPAXRPCRB). For 16A and above, the assembly is mounted via a DIN Rail Adapter Plate (XTPAXTPCPC, XTPAXT- M M PCPD) and the electrical connection is made 3 ~ 3 ~ with electrical contact modules (XTPAX- ECMC, XTPAXECMD), both included in XTPAXTPCC and XTPAXTPCD. For detailed component lists, see Table 34-196, Page 34- Figure 34-133. XTFC Combination Motor Figure 34-134. XTFR Combination Motor 167. Controller Controller of current Service Factor Settings: Setting I r scale in dependence of load factor: = 1 x I SF = 1.15 ➔ I r n mot SF = 1 ➔ I = 0.9 x I r n mot Single-phasing sensitivity to IEC/ EN 60947-4-1, VDE 0660 Part 102. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-162 XT IEC Power Control March 2009 Combination Motor Controllers Table 34-191. AC and DC Coil Suffixes Coil Voltage Suffix Code Coil Voltage Suffix Code Frame B Contactors Frame C and D Contactors 110V 50 Hz, 120V 60 Hz A 110V 50 Hz, 120V 60 Hz A 220V 50 Hz, 240V 60 Hz B 220V 50 Hz, 240V 60 Hz B 230V 50 Hz F 230V 50 Hz F 24V 50/60 Hz T 24V 50/60 Hz T 34 � � 24V DC TD 24 – 27V DC TD 415V 50 Hz, 480V 60 Hz C 415V 50 Hz, 480V 60 Hz C 550V 50 Hz, 600V 60 Hz D 550V 50 Hz, 600V 60 Hz D 208V 60 Hz E 208V 60 Hz E 190V 50 Hz, 220V 60 Hz G 190V 50 Hz, 220V 60 Hz G 240V 50 Hz, 277V 60 Hz H 240V 50 Hz, 277V 60 Hz H 380V 50 Hz, 440V 60 Hz L 380V 50 Hz, 440V 60 Hz L 400V 50 Hz N 400V 50 Hz N 380V 60 Hz P 380V 60 Hz P 12V 50/60 Hz R 12V 50/60 Hz R 24V 50 Hz U 24V 50 Hz U 42V 50 Hz, 48V 60 Hz W 42V 50 Hz, 48V 60 Hz W 48V 50 Hz Y 48V 50 Hz Y � � 120V DC AD 110 – 130V DC AD � � 220V DC BD 200 – 240V DC BD � � 12V DC RD 12 – 14V DC RD � � 48V DC WD 48 – 60V DC WD � With DC Operation: Integrated diode-resistor combination, coil rating 2.6W. Accessories Line Side Adapters Line Side Adapters are required for use with XTPR MMPs only when used as Type E Self-Protected Manual Combination Starters or as part of XTFC or XTFR Type F Combination Motor Controllers. Not required for Group Installation. Table 34-192. Line Side Adapters Description Catalog Price Number U.S. $ For use with Frame B MMPs (up to 32A) XTPAXLSA For use with Frame D MMPs (up to 40A) XTPAXLSAD Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-163 XT IEC Power Control March 2009 Combination Motor Controllers Combination Connection Kits Combination Connection Kits include the necessary components to field assemble a Manual Motor Controller with an MMP (XTPR) and Contactor (XTCE). Table 34-193. Combination Connection Kits For Use Description Std. Catalog Price with… Pack Number U.S. $ Non-reversing Starters 34 XTPR...B + XTCE...B Comprised of: 1 XTPAXTPCB ■ Mechanical connection element for XTPR...B and contactor ■ Main current wiring between XTPR...B and contactor in tool-less plug connection ■ Cable guidance Use as contactor auxiliary switch XTCEXFAT_. 2 Control cable guidance: max. 6 cables up to 2.5 mm 2 external diameter or 4 cables up to 3.5 mm external diameter. XTPR...B + XTCE...C Comprised of: 1 XTPAXTPCC ■ DIN rail adapter plate XTPR...D + XTCE...D 1 XTPAXTPCD ■ Main current wiring between XTPR and contactor Reversing Starters XTPR...B + XTCE...B01_ Comprised of: 1 XTPAXTPCRB ■ Mechanical connection element for XTPR...B and contactor ■ Reversing starter main current wiring in tool-less plug connection ■ Control cables for electrical interlocking in tool- less plug connection: – K1M: A1 – K2M: 21 – K1M: 21 – K2M: A1 – K1M: A2 – K2M: A2 ■ Cable guidance Use as contactor auxiliary switch XTCEXFAT_. 2 Control cable guidance: max. 6 cables up to 2.5 mm 2 external diameter or 4 cables up to 3.5 mm external diameter. XTPR...B + XTCE...C Comprised of: 1 XTPAXTPCRC ■ DIN rail adapter plate ■ Reversing starter main current wiring Star-Delta Starter Sets XTPR...B + XTCE...B Comprised of: 1 XTPAXSDSB ■ DIN rail adapter plate ■ Main current wiring between XTPR...B and contactor ■ Electrical interlock between delta and star contactor ■ Use as contactor auxiliary switch XTCEXFAT_ XTPR...B + XTCE...C Comprised of: 1 XTPAXSDSC ■ DIN rail adapter plate ■ Main current wiring between XTPR...B and contactor Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-164 XT IEC Power Control March 2009 Combination Motor Controllers Combination Connection Kits Table 34-193. Combination Connection Kits (Continued) For Use Description Std. Catalog Price � with… Pack Number U.S. $ Electric Contact Module XTPR...B + XTCE...C Comprised of: 5 XTPAXECMC ■ Main current wiring between XTPR...B and contactor 34 ■ Use only in combination with busbar adapter XTPR...D + XTCE...D Comprised of: 5 XTPAXECMD ■ Main current wiring between XTPR...D and contactor ■ Use only in combination with busbar adapter DIN Rail Adapter Plates XTPAXTPCB Comprised of: 4 XTPAXTPCPB XTPAXTPCRB ■ 45 mm wide adapter plate with one DIN rail ■ Connection element for side-by-side positioning of further plates XTPR...B + XTCE...C Comprised of: 4 XTPAXTPCRPB XTPAXECMC ■ 45 mm wide adapter plate with two DIN rails ■ Connection element for side-by-side positioning of further plates XTPAXECMD Comprised of: 4 XTPAXTPCPD XTPR...D + XTCE...C ■ 55 mm wide adapter plate with two DIN rails XTPR...D + XTCE...D ■ Connection cams for further plates ■ For use with reversing and star-delta starters Lateral Module — ■ Can be grouped on the DIN rail adapter 10 XTPAXLM ■ Expansion of the mounting width by 9 mm Connection Element — ■ For connection of several DIN rail adapters 50 XTPAXCNE � Orders must be placed in multiples of package quantity listed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-165 XT IEC Power Control March 2009 Combination Motor Controllers Technical Data and Specifications Table 34-194. Manual and Combination Motor Controllers Motor Ratings � � Assembled Controller FLA Maximum Motor Ratings — P Adjustment Maximum Motor kW Rating Maximum hp Rating — P (hp) Range / AC-3 — P (kW) Overload Three-Phase Single-Phase Three-Phase Release — Non-reversing Reversing 220 – 380 – 440V 500V 660 – 115V 200V 208V 240V 200V 208V 240V 480V 600V I (Amps) r 34 240V 415V 690V XTSC & XTSR Manual Motor Controllers (MMC) / Starter Combinations XTSC & XTSR Frame B MMP + Frame B Contactor � � � � � � � XTSCP16BB_ XTSRP16BB_ 0.1 – 0.16 — — — — 0.06 1/2 1/2 � � � � � � � XTSCP25BB_ XTSRP25BB_ 0.16 – 0.25 — 0.06 0.06 0.06 0.12 1/2 1/2 � � � � � � � XTSCP40BB_ XTSRP40BB_ 0.25 – 0.4 0.06 0.09 0.12 0.12 0.18 1/2 1/2 � � � � � � � XTSCP63BB_ XTSRP63BB_ 0.4 – 0.63 0.09 0.18 0.18 0.25 0.25 1/2 1/2 � � � � � � � XTSC001BB_ XTSR001BB_ 0.63 – 1 0.12 0.25 0.25 0.37 0.55 1/2 1/2 � � � � � � XTSC1P6BB_ XTSR1P6BB_ 1 – 1.6 0.25 0.55 0.55 0.75 1.1 1/10 3/4 1 XTSC2P5BB_ XTSR2P5BB_ 1.6 – 2.5 0.37 0.75 1.1 1.1 1.5 — 1/8 1/8 1/6 1/2 1/2 1/2 1 1-1/2 XTSC004BB_ XTSR004BB_ 2.5 – 4 0.75 1.5 1.5 2.2 3 1/8 1/4 1/4 1/3 1 1 1 2 3 XTSC6P3BB_ XTSR6P3BB_ 4 – 6.3 1.1 2.2 3 3 4 1/4 1/2 1/2 1/2 1-1/2 1-1/2 1-1/2 3 5 XTSC010BB_ XTSR010BB_ 6.3 – 10 2.2 4 4 4 7.5 1/2 1 1 1-1/2 3 3 3 7-1/2 10 XTSC012BB_ XTSR012BB_ 8 – 12 3 5.5 5.5 5.5 11 1/2 1-1/2 1-1/2 2 3 3 3 7-1/2 10 XTSC016BB_ — 10 – 16 4 7.5 9 9 12.5 1 2 2 2 3 3 3 10 10 XTSC & XTSR Frame B MMP + Frame C Contactor XTSC016BC_ XTSR016BC_ 10 – 16 4 7.5 9 9 12.5 1 2 2 2 3 3 5 10 10 XTSC020BC_ XTSR020BC_ 16 – 20 5.5 9 11 12.5 15 1-1/2 3 3 3 5 5 5 10 15 XTSC025BC_ XTSR025BC_ 20 – 25 5.5 11 12.5 15 22 1-1/2 3 3 3 5 5 7-1/2 15 20 XTSC032BC_ XTSR032BC_ 25 – 32 7.5 15 15 22 30 2 3 3 5 7-1/2 7-1/2 10 20 25 XTSC & XTSR Frame D MMP + Frame C Contactor XTSC016DC_ XTSR016DC_ 10 – 16 4 7.5 9 9 12.5 1 2 2 3 3 5 5 10 15 XTSC025DC_ XTSR025DC_ 16 – 25 5.5 12.5 12.5 12.5 22 2 3 3 3 7-1/2 7-1/2 7-1/2 20 25 XTSC032DC_ XTSR032DC_ 25 – 32 7.5 15 17.5 17.5 22 3 5 5 5 10 10 10 25 30 XTSC & XTSR Frame D MMP + Frame D Contactor XTSC040DD_ XTSR040DD_ 32 – 40 11 20 22 22 30 3 5 — 7-1/2 10 — — 30 30 XTSC050DD_ XTSR050DD_ 40 – 50 14 25 30 30 45 — 7-1/2 7-1/2 — 15 15 15 30 40 XTSC058DD_ XTSR058DD_ 50 – 58 17 30 37 37 55 — — — 10 — — — 40 — XTSC063DD_ XTSR063DD_ 55 – 63 18.5 34 37 37 55 — — — — — — — 40 — XTFC & XTFR Combination Motor Controllers (CMC), UL508 Type F XTFC & XTFR Frame B MMP + Frame B Contactor � � � � � � � XTFCP16BB_ XTFRP16BB_ 0.1 – 0.16 — — — — 0.06 1/2 1/2 � � � � � � � XTFCP25BB_ XTFRP25BB_ 0.16 – 0.25 — 0.06 0.06 0.06 0.12 1/2 1/2 � � � � � � � XTFCP40BB_ XTFRP40BB_ 0.25 – 0.4 0.06 0.09 0.12 0.12 0.18 1/2 1/2 � � � � � � � XTFCP63BB_ XTFRP63BB_ 0.4 – 0.63 0.09 0.18 0.18 0.25 0.25 1/2 1/2 � � � � � � � XTFC001BB_ XTFR001BB_ 0.63 – 1 0.12 0.25 0.25 0.37 0.55 1/2 1/2 � � � � � � XTFC1P6BB_ XTFR1P6BB_ 1 – 1.6 0.25 0.55 0.55 0.75 1.1 1/10 3/4 1 XTFC2P5BB_ XTFR2P5BB_ 1.6 – 2.5 0.37 0.75 1.1 1.1 1.5 — 1/8 1/8 1/6 1/2 1/2 1/2 1 1-1/2 XTFC004BB_ XTFR004BB_ 2.5 – 4 0.75 1.5 1.5 2.2 3 1/8 1/4 1/4 1/3 1 1 1 2 3 XTFC6P3BB_ XTFR6P3BB_ 4 – 6.3 1.1 2.2 3 3 4 1/4 1/2 1/2 1/2 1-1/2 1-1/2 1-1/2 3 5 XTFC010BB_ XTFR010BB_ 6.3 – 10 2.2 4 4 4 7.5 1/2 1 1 1-1/2 3 3 3 7-1/2 10 XTFC012BB_ XTFR012BB_ 8 – 12 3 5.5 5.5 5.5 11 1/2 1-1/2 1-1/2 2 3 3 3 7-1/2 — XTFC016BB_ — 10 – 16 4 7.5 9 9 12.5 1 2 2 2 3 3 3 10 — XTFC & XTFR Frame B MMP + Frame C Contactor XTFC016BC_ XTFR016BC_ 10 – 16 4 7.5 9 9 12.5 1 2 2 2 3 3 5 10 — XTFC020BC_ XTFR020BC_ 16 – 20 5.5 9 11 12.5 15 1-1/2 3 3 3 5 5 5 10 — XTFC025BC_ XTFR025BC_ 20 – 25 5.5 11 12.5 15 22 1-1/2 3 3 3 5 5 7-1/2 15 — XTFC032BC_ XTFR032BC_ 25 – 32 7.5 15 15 22 30 2 3 3 5 7-1/2 7-1/2 10 20 — XTFC & XTFR Frame D MMP + Frame C Contactor XTFC016DC_ XTFR016DC_ 10 – 16 4 7.5 9 9 12.5 1 2 2 3 3 5 5 10 15 XTFC025DC_ XTFR025DC_ 16 – 25 5.5 12.5 12.5 12.5 22 2 3 3 3 7-1/2 7-1/2 7-1/2 20 25 XTFC032DC_ XTFR032DC_ 25 – 32 7.5 15 17.5 17.5 22 3 5 5 5 10 10 10 25 30 XTFC & XTFR Frame D MMP + Frame D Contactor XTFC040DD_ XTFR040DD_ 32 – 40 11 20 22 22 30 3 5 — 7-1/2 10 — — 30 30 � Select Manual Motor Protectors by full load amperes. Maximum Motor Ratings (kW, hp) are for reference only. � In this range, calculate motor rating according to rated current. Specified values to NEC Table 430-250. � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-191 on Page 34-162. Notes: Service Factor Settings: Setting I of current Single-phasing sensitivity to IEC/ r scale in dependence of load factor: EN 60947-4-1, VDE 0660 Part 102. SF = 1.15 ➔ I = 1 x I r n mot SF = 1 ➔ I = 0.9 x I r n mot CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-166 XT IEC Power Control March 2009 Combination Motor Controllers Table 34-195. XTSC and XTSR Manual Motor Controllers (MMC) / Starter Combinations — Component Bill of Material Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor Assembled Manual FLA Adjustment Range / Component Catalog Numbers � Motor Controller Overload Release — I � r Manual Motor Combination Contactor Manual Motor Protector (Amps) Protector Connection Kit Auxiliary Contact Non-reversing XTSC Frame B MMP + Frame B Contactor 34 XTSCP16BB_ 0.1 – 0.16 XTPRP16BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTSCP25BB_ 0.16 – 0.25 XTPRP25BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTSCP40BB_ 0.25 – 0.4 XTPRP40BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTSCP63BB_ 0.4 – 0.63 XTPRP63BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTSC001BB_ 0.63 – 1 XTPR001BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTSC1P6BB_ 1 – 1.6 XTPR1P6BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTSC2P5BB_ 1.6 – 2.5 XTPR2P5BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTSC004BB_ 2.5 – 4 XTPR004BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTSC6P3BB_ 4 – 6.3 XTPR6P3BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTSC010BB_ 6.3 – 10 XTPR010BC1 XTPAXTPCB XTCE009B10_ XTPAXFA11 XTSC012BB_ 8 – 12 XTPR012BC1 XTPAXTPCB XTCE012B10_ XTPAXFA11 XTSC016BB_ 10 – 16 XTPR016BC1 XTPAXTPCB XTCE015B10_ XTPAXFA11 XTSC Frame B MMP + Frame C Contactor XTSC016BC_ 10 – 16 XTPR016BC1 XTPAXTPCC XTCE018C10_ XTPAXFA11 XTSC020BC_ 16 – 20 XTPR020BC1 XTPAXTPCC XTCE025C10_ XTPAXFA11 XTSC025BC_ 20 – 25 XTPR025BC1 XTPAXTPCC XTCE025C10_ XTPAXFA11 XTSC032BC_ 25 – 32 XTPR032BC1 XTPAXTPCC XTCE032C10_ XTPAXFA11 XTSC Frame D MMP + Frame C Contactor � XTSC016DC_ 10 – 16 XTPR016DC1 XTCE018C10_ XTPAXFA11 � XTSC025DC_ 16 – 25 XTPR025DC1 XTCE025C10_ XTPAXFA11 � XTSC032DC_ 25 – 32 XTPR032DC1 XTCE032C10_ XTPAXFA11 XTSC Frame D MMP + Frame D Contactor � XTSC040DD_ 32 – 40 XTPR040DC1 XTPAXTPCD XTCE040D00_ XTPAXFA11 � XTSC050DD_ 40 – 50 XTPR050DC1 XTPAXTPCD XTCE050D00_ XTPAXFA11 � XTSC058DD_ 50 – 58 XTPR058DC1 XTPAXTPCD XTCE065D00_ XTPAXFA11 � XTSC063DD_ 55 – 63 XTPR063DC1 XTPAXTPCD XTCE065D00_ XTPAXFA11 Reversing XTSR Frame B MMP + Frame B Contactor XTSRP16BB_ 0.1 – 0.16 XTPBP16BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTSRP25BB_ 0.16 – 0.25 XTPRP25BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTSRP40BB_ 0.25 – 0.4 XTPRP40BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTSRP63BB_ 0.4 – 0.63 XTPRP63BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTSR001BB_ 0.63 – 1 XTPR001BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTSR1P6BB_ 1 – 1.6 XTPR1P6BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTSR2P5BB_ 1.6 – 2.5 XTPR2P5BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTSR004BB_ 2.5 – 4 XTPR004BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTSR6P3BB_ 4 – 6.3 XTPR6P3BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTSR010BB_ 6.3 – 10 XTPR010BC1 XTPAXTPCRB (2) XTCE009B01_ XTPAXFA11 XTSR012BB_ 8 – 12 XTPR012BC1 XTPAXTPCRB (2) XTCE012B01_ XTPAXFA11 XTSR Frame B MMP + Frame C Contactor XTSR016BC_ 10 – 16 XTPR016BC1 XTPAXTPCRC (2) XTCE018C01_ XTPAXFA11 XTSR020BC_ 16 – 20 XTPR020BC1 XTPAXTPCRC (2) XTCE025C01_ XTPAXFA11 XTSR025BC_ 20 – 25 XTPR025BC1 XTPAXTPCRC (2) XTCE025C01_ XTPAXFA11 XTSR032BC_ 25 – 32 XTPR032BC1 XTPAXTPCRC (2) XTCE032C01_ XTPAXFA11 XTSR Frame D MMP + Frame C Contactor � XTSR016DC_ 10 – 16 XTPR016DC1 (2) XTCE018C01_ XTPAXFA11 � XTSR025DC_ 16 – 25 XTPR025DC1 (2) XTCE025C01_ XTPAXFA11 � XTSR032DC_ 25 – 32 XTPR032DC1 (2) XTCE032C01_ XTPAXFA11 XTSR Frame D MMP + Frame D Contactor � XTSR040DD_ 32 – 40 XTPR040DC1 (2) XTCE040D00_ XTPAXFA11 � XTSR050DD_ 40 – 50 XTPR050DC1 (2) XTCE050D00_ XTPAXFA11 � XTSR058DD_ 50 – 58 XTPR058DC1 (2) XTCE065D00_ XTPAXFA11 � XTSR063DD_ 55 – 63 XTPR063DC1 (2) XTCE065D00_ XTPAXFA11 � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-191 on Page 34-162. � The connection between the XTPR…DC1 and the XTCE…C... contactor will be made with flexible wire and mounted to the DIN Rail Adapter Plate (XTPAXTPCPD). � The reversing connection between the XTPR…DC1 and the (2) XTCE…C… contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN Rail Adapter Plate (XTPAXTPCPD), and DIN Adapter Connection Element (XTPAXCNE). For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-167 XT IEC Power Control March 2009 Combination Motor Controllers Table 34-196. XTFC and XTFR Combination Motor Controllers (CMC), UL508 Type F — Component Bill of Material Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor + Required Line Side Adapter Assembled FLA Adjustment Range / Component Catalog Numbers Combination Overload Release — I � r Line Side Manual Motor Combination Contactor Manual Motor � Motor Controller (Amps) Adapter Protector Connection Kit Protector Auxiliary Contact Non-reversing XTFC Frame B MMP + Frame B Contactor 34 XTFCP16BB_ 0.1 – 0.16 XTPAXLSA XTPRP16BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTFCP25BB_ 0.16 – 0.25 XTPAXLSA XTPRP25BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTFCP40BB_ 0.25 – 0.4 XTPAXLSA XTPRP40BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTFCP63BB_ 0.4 – 0.63 XTPAXLSA XTPRP63BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTFC001BB_ 0.63 – 1 XTPAXLSA XTPR001BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTFC1P6BB_ 1 – 1.6 XTPAXLSA XTPR1P6BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTFC2P5BB_ 1.6 – 2.5 XTPAXLSA XTPR2P5BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTFC004BB_ 2.5 – 4 XTPAXLSA XTPR004BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTFC6P3BB_ 4 – 6.3 XTPAXLSA XTPR6P3BC1 XTPAXTPCB XTCE007B10_ XTPAXFA11 XTFC010BB_ 6.3 – 10 XTPAXLSA XTPR010BC1 XTPAXTPCB XTCE009B10_ XTPAXFA11 XTFC012BB_ 8 – 12 XTPAXLSA XTPR012BC1 XTPAXTPCB XTCE012B10_ XTPAXFA11 XTFC016BB_ 10 – 16 XTPAXLSA XTPR016BC1 XTPAXTPCB XTCE015B10_ XTPAXFA11 XTFC Frame B MMP + Frame C Contactor XTFC016BC_ 10 – 16 XTPAXLSA XTPR016BC1 XTPAXTPCC XTCE018C10_ XTPAXFA11 XTFC020BC_ 16 – 20 XTPAXLSA XTPR020BC1 XTPAXTPCC XTCE025C10_ XTPAXFA11 XTFC025BC_ 20 – 25 XTPAXLSA XTPR025BC1 XTPAXTPCC XTCE025C10_ XTPAXFA11 XTFC032BC_ 25 – 32 XTPAXLSA XTPR032BC1 XTPAXTPCC XTCE032C10_ XTPAXFA11 XTFC Frame D MMP + Frame C Contactor � XTFC016DC_ 10 – 16 XTPAXLSAD XTPR016DC1 XTCE018C10_ XTPAXFA11 � XTFC025DC_ 16 – 25 XTPAXLSAD XTPR025DC1 XTCE025C10_ XTPAXFA11 � XTFC032DC_ 25 – 32 XTPAXLSAD XTPR032DC1 XTCE032C10_ XTPAXFA11 XTFC Frame D MMP + Frame D Contactor � XTFC040DD_ 32 – 40 XTPAXLSAD XTPR040DC1 XTPAXTPCD XTCE040D00_ XTPAXFA11 � XTFC050DD_ 40 – 50 XTPAXLSAD XTPR050DC1 XTPAXTPCD XTCE050D00_ XTPAXFA11 � XTFC058DD_ 50 – 58 XTPAXLSAD XTPR058DC1 XTPAXTPCD XTCE065D00_ XTPAXFA11 � XTFC063DD_ 55 – 63 XTPAXLSAD XTPR063DC1 XTPAXTPCD XTCE065D00_ XTPAXFA11 Reversing XTFR Frame B MMP + Frame B Contactor XTFRP16BB_ 0.1 – 0.16 XTPAXLSA XTPRP16BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTFRP25BB_ 0.16 – 0.25 XTPAXLSA XTPRP25BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTFRP40BB_ 0.25 – 0.4 XTPAXLSA XTPRP40BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTFRP63BB_ 0.4 – 0.63 XTPAXLSA XTPRP63BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTFR001BB_ 0.63 – 1 XTPAXLSA XTPR001BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTFR1P6BB_ 1 – 1.6 XTPAXLSA XTPR1P6BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTFR2P5BB_ 1.6 – 2.5 XTPAXLSA XTPR2P5BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTFR004BB_ 2.5 – 4 XTPAXLSA XTPR004BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTFR6P3BB_ 4 – 6.3 XTPAXLSA XTPR6P3BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11 XTFR010BB_ 6.3 – 10 XTPAXLSA XTPR010BC1 XTPAXTPCRB (2) XTCE009B01_ XTPAXFA11 XTFR012BB_ 8 – 12 XTPAXLSA XTPR012BC1 XTPAXTPCRB (2) XTCE012B01_ XTPAXFA11 XTFR Frame B MMP + Frame C Contactor XTFR016BC_ 10 – 16 XTPAXLSA XTPR016BC1 XTPAXTPCRC (2) XTCE018C01_ XTPAXFA11 XTFR020BC_ 16 – 20 XTPAXLSA XTPR020BC1 XTPAXTPCRC (2) XTCE025C01_ XTPAXFA11 XTFR025BC_ 20 – 25 XTPAXLSA XTPR025BC1 XTPAXTPCRC (2) XTCE025C01_ XTPAXFA11 XTFR032BC_ 25 – 32 XTPAXLSA XTPR032BC1 XTPAXTPCRC (2) XTCE032C01_ XTPAXFA11 XTFR Frame D MMP + Frame C Contactor � XTFR016DC_ 10 – 16 XTPAXLSAD XTPR016DC1 (2) XTCE018C01_ XTPAXFA11 � XTFR025DC_ 16 – 25 XTPAXLSAD XTPR025DC1 (2) XTCE025C01_ XTPAXFA11 � XTFR032DC_ 25 – 32 XTPAXLSAD XTPR032DC1 (2) XTCE032C01_ XTPAXFA11 XTFR Frame D MMP + Frame D Contactor � XTFR040DD_ 32 – 40 XTPAXLSAD XTPR040DC1 (2) XTCE040D00_ XTPAXFA11 � XTFR050DD_ 40 – 50 XTPAXLSAD XTPR050DC1 (2) XTCE050D00_ XTPAXFA11 � XTFR058DD_ 50 – 58 XTPAXLSAD XTPR058DC1 (2) XTCE065D00_ XTPAXFA11 � XTFR063DD_ 55 – 63 XTPAXLSAD XTPR063DC1 (2) XTCE065D00_ XTPAXFA11 � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-191 on Page 34-162. � The connection between the XTPR…DC1 and the XTCE…C... contactor will be made with flexible wire and mounted to the DIN Rail Adapter Plate (XTPAXTPCPD). � The reversing connection between the XTPR…DC1 and the (2) XTCE…C... contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN Rail Adapter Plate (XTPAXTPCPD), and DIN Adapter Connection Element (XTPAXCNE). CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-168 XT IEC Power Control March 2009 Combination Motor Controllers Table 34-197. Manual Motor Controllers Short-Circuit Ratings for UL/CSA Group Installations XTSC & XTSR Manual Motor Controllers (MMC) / Starter Combinations � Assembled Controller FLA Adjustment Short-Circuit Group Installation, UL/CSA Range / Overload Release — I rm Max. RMS Symmetrical Short-Circuit Maximum Upstream Protective Device Release — I (Amps) r Ratings (kA / kA with Current Limiter) (A / A with Current Limiter) (Amps) Non-reversing Reversing 240V 480V 600V Maximum Fuse Maximum 600V Circuit Breaker 600V 34 XTSC & XTSR Frame B MMP + Frame B Contactor XTSCP16BB_ XTSRP16BB_ 0.1 – 0.16 2.2 50 50 50 600 600 XTSCP25BB_ XTSRP25BB_ 0.16 – 0.25 3.5 50 50 50 600 600 XTSCP40BB_ XTSRP40BB_ 0.25 – 0.4 5.6 50 50 50 600 600 XTSCP63BB_ XTSRP63BB_ 0.4 – 0.63 8.82 50 50 50 600 600 XTSC001BB_ XTSR001BB_ 0.63 – 1 14 50 50 50 600 600 XTSC1P6BB_ XTSR1P6BB_ 1 – 1.6 22.4 50 50 50 600 600 XTSC2P5BB_ XTSR2P5BB_ 1.6 – 2.5 35 50 50 50 600 600 XTSC004BB_ XTSR004BB_ 2.5 – 4 56 50 50 50 600 600 XTSC6P3BB_ XTSR6P3BB_ 4 – 6.3 88.2 50 50 50 600 600 XTSC010BB_ XTSR010BB_ 6.3 – 10 140 22 22 22 150 / 600 125 / 600 XTSC012BB_ XTSR012BB_ 8 – 12 168 10 / 50 10 / 50 10 / 50 150 / 600 125 / 600 XTSC016BB_ — 10 – 16 224 10 / 50 10 / 50 10 / 50 150 / 600 125 / 600 XTSC & XTSR Frame B MMP + Frame C Contactor XTSC016BC_ XTSR016BC_ 10 – 16 224 10 / 50 10 / 50 10 / 50 150 / 600 125 / 600 XTSC020BC_ XTSR020BC_ 16 – 20 280 10 / 18 10 / 18 10 / 18 150 / 600 125 / 600 XTSC025BC_ XTSR025BC_ 20 – 25 350 10 / 18 10 / 18 10 / 18 150 / 600 125 / 600 XTSC032BC_ XTSR032BC_ 25 – 32 448 5 / 18 5 / 18 5 / 18 150 / 600 125 / 600 XTSC & XTSR Frame D MMP + Frame C Contactor XTSC016DC_ XTSR016DC_ 10 – 16 224 50 50 10 600 600 XTSC025DC_ XTSR025DC_ 16 – 25 350 50 50 10 600 600 XTSC032DC_ XTSR032DC_ 25 – 32 448 50 50 10 600 600 XTSC & XTSR Frame D MMP + Frame D Contactor XTSC040DD_ XTSR040DD_ 32 – 40 560 50 50 10 600 600 XTSC050DD_ XTSR050DD_ 40 – 50 700 50 50 10 600 600 XTSC058DD_ XTSR058DD_ 50 – 58 812 50 50 — — — XTSC063DD_ XTSR063DD_ 55 – 63 882 50 50 — — — � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-191 on Page 34-162. Table 34-198. Combination Motor Controllers Short Circuit Ratings for UL 508 Type F Application XTFC & XTFR Combination Motor Controllers (CMC), UL 508 Type F � Assembled Controller FLA Adjustment Short-Circuit UL 508 Type F Application Range / Overload Release — I rm Max. RMS Symmetrical Short-Circuit Maximum Upstream Release — I (Amps) � r Ratings (kA) Protective Device (A) (Amps) Non-reversing Reversing 240V 480/277V 600/347V Maximum Fuse Maximum 600V Circuit Breaker 600V XTFC & XTFR Frame B MMP + Frame B Contactor XTFCP16BB_ XTFRP16BB_ 0.1 – 0.16 2.2 50 50 30 Not Required Not Required XTFCP25BB_ XTFRP25BB_ 0.16 – 0.25 3.5 50 50 30 Not Required Not Required XTFCP40BB_ XTFRP40BB_ 0.25 – 0.4 5.6 50 50 30 Not Required Not Required XTFCP63BB_ XTFRP63BB_ 0.4 – 0.63 8.82 50 50 30 Not Required Not Required XTFC001BB_ XTFR001BB_ 0.63 – 1 14 50 50 30 Not Required Not Required XTFC1P6BB_ XTFR1P6BB_ 1 – 1.6 22.4 50 50 30 Not Required Not Required XTFC2P5BB_ XTFR2P5BB_ 1.6 – 2.5 35 50 50 30 Not Required Not Required XTFC004BB_ XTFR004BB_ 2.5 – 4 56 50 50 30 Not Required Not Required XTFC6P3BB_ XTFR6P3BB_ 4 – 6.3 88.2 50 50 30 Not Required Not Required XTFC010BB_ XTFR010BB_ 6.3 – 10 140 50 50 — Not Required Not Required XTFC012BB_ XTFR012BB_ 8 – 12 168 42 42 — Not Required Not Required XTFC016BB_ — 10 – 16 224 42 42 — Not Required Not Required XTFC & XTFR Frame B MMP + Frame C Contactor XTFC016BC_ XTFR016BC_ 10 – 16 224 18 18 — Not Required Not Required XTFC020BC_ XTFR020BC_ 16 – 20 280 18 18 — Not Required Not Required XTFC025BC_ XTFR025BC_ 20 – 25 350 18 18 — Not Required Not Required XTFC032BC_ XTFR032BC_ 25 – 32 448 18 18 — Not Required Not Required XTFC & XTFR Frame D MMP + Frame C Contactor XTFC016DC_ XTFR016DC_ 10 – 16 224 50 50 50 Not Required Not Required XTFC025DC_ XTFR025DC_ 16 – 25 350 50 50 50 Not Required Not Required XTFC032DC_ XTFR032DC_ 25 – 32 448 50 50 50 Not Required Not Required XTFC & XTFR Frame D MMP + Frame D Contactor XTFC040DD_ XTFR040DD_ 32 – 40 560 50 50 50 Not Required Not Required XTFC050DD_ XTFR050DD_ 40 – 50 700 65 65 — Not Required Not Required XTFC058DD_ XTFR058DD_ 50 – 58 812 65 65 — Not Required Not Required XTFC063DD_ XTFR063DD_ 55 – 65 882 65 65 — Not Required Not Required � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-191 on Page 34-162. � For UL508 Type F applications, the Combination Motor Controller assembly does not require a dedicated upstream protective device in the panel, thus a maximum rating is not required. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-169 XT IEC Power Control March 2009 Combination Motor Controllers Dimensions 32.5 [1.28] To Terminals 34 178.5 [7.03] 49.7 [1.96] To Terminals 95.7 45 [3.77] [1.77] Figure 34-135. XTSC…BB_ — Approximate Dimensions in mm [in] 32.5 [1.28] To Terminals 183.4 [7.22] 49.7 [1.96] To Terminals 95.3 90.3 [3.75] [3.55] Figure 34-136. XTSR…BB_ — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-170 XT IEC Power Control March 2009 Combination Motor Controllers Mounting Holes 57.5 [2.26] for M4 Screws To Terminals or #8 Screws (4 Places) 34 235.7 210.8 [8.30] 228.8 [9.28] Mounting [9.01] 86.8 [3.42] To Terminals 9 [.35] 34 124.3 45.2 [1.34] [4.89] [1.78] Figure 34-137. XTSC…BC_ — Approximate Dimensions in mm [in] Mounting Holes for M4 Screws or #8 Screws 57.5 [2.26] (4 Places) To Terminals 235.4 210.8 [8.30] 228.8 [9.27] Mounting [9.01] 86.8 [3.42] To Terminals 9 [.35] 34 124.3 89.6 [1.34] [4.89] [3.53] 45 [1.77] 79 5.3 [3.11] [.21] Figure 34-138. XTSR…BC_ — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-171 XT IEC Power Control March 2009 Combination Motor Controllers 196 [7.72] Mounting Holes for M5 Screws or #10 Screws 83.4 [3.28] (4 Places) To Terminals 34 266 [10.47] 284 Mounting [11.18] 142.8 [5.62] To Coil Terminals 9 [.35] 158.5 55 [2.17] [6.24] 43.4 [1.71] 172.1 [6.78] Mounting To Optional Aux. Contacts Figure 34-139. XTSC…DD_ — Approximate Dimensions in mm [in] 36.3 [1.43] To Terminals 209.2 [8.24] 49.7 [1.96] To Terminals 95.7 [3.77] 45 [1.77] Figure 34-140. XTFC…BB_ — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-172 XT IEC Power Control March 2009 Combination Motor Controllers 36.3 [1.43] To Terminals 34 214.2 [8.43] 49.7 [1.96] To Terminals 90.3 95.3 [3.55] [3.75] Figure 34-141. XTFR…BB_ — Approximate Dimensions in mm [in] 34 [1.34] 61.3 [2.41] Mounting To Terminals Mounting Holes for M4 Screws or #8 Screws (4 Places) 266.7 [10.50] 235.7 210.8 [8.30] 228.8 [9.28] Mounting [9.01] 86.8 [3.42] To Terminals 9 [.35] 124.3 45.2 [4.89] [1.78] Figure 34-142. XTFC…BC_ — Approximate Dimensions in mm [in] For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-173 XT IEC Power Control March 2009 Combination Motor Controllers 61.3 [2.41] To Terminals Mounting Holes for M4 Screws or #8 Screws (8 Places) 34 266.4 [10.49] 235.4 210.8 [9.27] [8.30] 228.8 [9.01] 86.8 [3.42] To Terminals 9 [.35] 34 [1.34] 124.3 [4.89] 89.6 [3.53] 45 [1.77] 79 [3.11] 5.3 [.21] Figure 34-143. XTFR…BC_ — Approximate Dimensions in mm [in] 86 [3.39] Mounting Holes for To Line Side M5 Screws or #10 Screws Connector (4 Places) 297 [11.69] 266 [10.47] Mounting 284 [11.18] 142.8 [5.62] To Coil Terminals 9 [.35] 158.5 [6.24] 43.4 [1.71] 55 [2.17] Mounting 172.1 [6.78] To Optional Aux. Contacts Figure 34-144. XTFC…DD_ — Approximate Dimensions in mm [in] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-174 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Product Description Short Circuit Ratings ® Eaton’s Cutler-Hammer XT Line ■ Fused, Non-fused includes IEC Contactors, Starters ❑ 10K AIC @ 600V and Combination Motor Controllers ■ HMCP (CMCs). Designed to meet Inter- ❑ 0 – 10 hp 15K AIC @ 600V national Standards, the Enclosed Control XT Line (ECX), carries UL ❑ 15 – 125 hp 25K AIC @ 600V 34 and cUL certifications. ■ Non-combination ❑ 0 – 1 hp 1K AIC @ 600V Features and Benefits ❑ 1.5 – 50 hp 5K AIC @ 600V ❑ 50 – 200 hp 10K AIC @ 600V ■ AC control from 12V to 600V 50/60 Hz ■ DC control from 12V to 220V Standards and Certifications ■ Available with screw or spring cage Note: See Enclosed Control Product Guide terminals PG0300001E for additional information on ■ Reversing or non-reversing Standards and Certifications that apply to contactors and starters all Cutler-Hammer Enclosed Control products. ■ AC-3 contactor ratings to 1000A and AC-1 contactor ratings to 2000A ■ Fusible — with Class J fuses ■ Non-reversing starters to 650A ❑ UL Listed ■ Panel or DIN rail mounting to 65A � ❑ cUL Listed ■ IP20 finger and back-of-hand proof ■ Large ambient temperature range, ■ Circuit Breaker HMCP/E -25 to 50°C [-13 to 122°F] ❑ UL Listed ■ AC and DC controlled contactors in � ❑ cUL Listed the same compact frame � cUL Listing indicates appropriate CSA ■ Low power consumption DC coils ECX Enclosed Control standard investigation. ■ Built-in NO or NC auxiliary contacts to 32A ■ Plug-in accessories for reduced installation time ■ Nonmetallic and metallic enclosures in Types 1 (IP23), 4 (IP66), 4X (IP66), 12 (IP65) and 3R (IP32) ■ Circuit breakers, fused, non-fused and non-combination designs available ■ Opaque (standard) or clear covers available on nonmetallic Halyester enclosure option For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-175 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Catalog Number Selection Table 34-199. IEC XT Line Enclosed Control Catalog Numbering System E C X 2 5 E 5 A A A - Design Modification Codes X = XT IEC See PG03300001E 34 Class Table Overload Range 09 = Non-combination Non-reversing Starter 34-204 See Table 34-200 10 = Non-combination Reversing Starter 34-205 Disconnect Fuse Clip Ratings 11 = Non-combination Non-reversing Starter 34-206 with CPT A = None C = 30A J 19 = Combination Non-reversing Starter — 34-207 E = 60A J Fusible/Non-fusible Disconnect G = 100A J 20 = Combination Reversing Starter — 34-208 HMCP Ratings Fusible/Non-fusible Disconnect A = None 25 = Combination Non-reversing Starter — 34-209 B = 3A Circuit Breaker C = 7A 26 = Combination Reversing Starter — 34-210 D = 15A Circuit Breaker E = 30A F = 50A W = 70A Frame Size G = 100A Combination Non-combination (Class 09 – 11) H = 150A (Class 16 – 74) Ampere Rating (UL 600V) J = 250A IEC Size B – QB = 7A J = 40A C = 9A K = 50A Cover Control D = 12A L = 65A Type 1 Non-comb. Starters see Table 34-201 E = 15A M = 80A All Other Starters see Table 34-202 F = 18A N = 95A E22 Style Comb. Starters see Table 34-203 G = 25A P = 115A H = 32A Q = 150A Coil Voltage � Enclosure Type/IP Ratings A = 120V H = 277V B = 240V L = 380V/50 Hz 1 = Type 1— General Purpose/IP23 C = 480V Q = 24V DC 3 = Type 4 — Painted Steel/IP66 D = 600V T = 24V AC 4 = Type 4X — Watertight (304-Grade Stainless Steel)/IP66 E = 208V 5 = Type 4X — Watertight (Non-metallic)/IP66 8 = Type 12 — Dust-Tight/IP65 � See PG03300001E for Enclosure Type/IP Rating Cross-Reference. Table 34-200. XTOB Overload Relays for Enclosed XT FLA Size B – E Size F – H Size J – L Size M – N Size P – Q FLA Size B – E Size F – H Size J – L Size M – N Size P – Q Ratings 7 – 15A 18 – 32A 40 – 65A 80 – 95A 115 – 150A Ratings 7 – 15A 18 – 32A 40 – 65A 80 – 95A 115 – 150A 0.1 – 0.16 A A — — — 16 – 24 — M M — — 0.16 – 0.24 B B — — — 24 – 32 — N — — — 0.24 – 0.4 C C — — — 24 – 40 — — P — — 0.4 – 0.6 D D — — — 25 – 35 — — — S S 0.6 – 1 E E — — — 35 – 50 — — — T T 1 – 1.6 F F — — — 40 – 57 — — Q — — 1.6 – 2.4 G G — — — 50 – 65 — — R — — 2.4 – 4 H H — — — 50 – 70 — — — U U 4 – 6 I I — — — 70 – 100 — — — V V 6 – 10 J J J — — 95 – 125 — — — — W 9 – 12 K — — — — � 12 – 16 L L L — — � Size B – E is 10 – 16A. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-176 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Cover Control Non-combination Starters Control Power Transformer (CPT) may be required. Combination Starters ■ Cover control for Combination Starters uses 10250T 34 style devices as standard. 10250T Selector Switch ■ E22 style cover control options are available (Table 34-203). Table 34-202. Type 1 Combination and All Type 3R, 4X and 12 ■ Selector switches are maintained with lever operators. � Cover Control ■ Pushbuttons are momentary type with extended Description Factory Field Installation Kits pushbutton. Installed Flange ■ The kit includes hardware and connecting wires Control (where possible). Position Catalog Price ■ For factory installed control devices other than shown 9 Code Number U.S. $ below, refer to Modification Codes, PG03300001E. Non-reversing No Cover Mounted Pilot Devices A — START/STOP Pushbuttons B C400T1 with Red RUN Pilot Light C — with Red RUN/Green OFF Lights D — ON/OFF Pushbuttons E C400T2 with Red RUN Pilot Light F — with Red RUN/Green OFF Lights G — HAND/OFF/AUTO Selector Switch H C400T12 with Red RUN Pilot Light J — Type 1 Cover Control with Red RUN/Green OFF Lights K — START Pushbutton L C400T3 Table 34-201. Type 1 Non-combination Cover Control ON Pushbutton M C400T4 OFF Pushbutton N C400T5 Description Factory Field Installation Kits � Red RUN Pilot Light P C400T9 Installed � Green OFF Q C400T10 Flange � � Red RUN/Green OFF Pilot Lights R C400T11 Control START/STOP Selector Switch S C400T13 Position Catalog Price with Red RUN Pilot Light T — 9 Code Number U.S. $ with Red RUN/Green OFF Lights U — Non-reversing ON/OFF Selector Switch V C400T14 No Cover Mounted Pilot Devices A C400GK0 with Red RUN Pilot Light W — START/STOP Pushbuttons B C400GK1 with Red RUN/Green OFF Lights X — � with Red RUN Pilot Light C C400GK12 � Reversing with Red RUN/Green OFF Lights D C400GK16 No Cover Mounted Pilot Devices A — HAND/OFF/AUTO Selector Switch H C400GK3 � FOR/REV/STOP Pushbuttons B C400T6 with Red RUN Pilot Light J C400GK32 � with 2 Red Pilot Lights C — with Red RUN/Green OFF Lights K C400GK36 with 2 Red/1 Green Pilot Lights D — � Red RUN Pilot Light P C400GK42 � UP/STOP/DOWN Pushbuttons E — Green OFF Q C400GK41 � with 2 Red Pilot Lights F — Red RUN/Green OFF Pilot Lights R C400GK46 FOR/OFF/REV Selector Switch H C400T15 Reversing with 2 Red Pilot Lights J — No Cover Mounted Pilot Devices A C400GK0 with 2 Red/1 Green Pilot Lights K — FOR/REV/STOP Pushbuttons B C400GR1 � � Two Red Pilot Lights P with 2 Red Pilot Lights C C400GR14 � One Green Pilot Light Q C400T10 UP/STOP/DOWN Pushbuttons E C400GR2 Two Red/One Green Pilot Lights R — � with 2 Red Pilot Lights F C400GR24 OPEN/OFF/CLOSE Selector Switch V C400T16 � Two Red Pilot Lights P C400GK44 with 2 Red Pilot Lights W — � One Green Pilot Light Q C400GK41 with 2 Red/1 Green Pilot Lights X — � � For more available factory installed flange control, see Table 34-202. For Type 1 Non-combination field installation kits, see Table 34-201. � � Add Code Letter from the table below to Catalog Number for voltage — Add Code Letter from the table below to Catalog Number for voltage — Kits only. Example: C400T9B. Kits only. Example: C400T9B. Rating Code Rating Code Rating Code Rating Code Rating Code Rating Code Letter Letter Letter Letter Letter Letter 120V 60 Hz A 277V 60 Hz H 480V 60 Hz C 120V 60 Hz A 277V 60 Hz H 480V 60 Hz C 208V 60 Hz E 380V 50 Hz L 600V 60 Hz D 208V 60 Hz E 380V 50 Hz L 600V 60 Hz D 240V 60 Hz B 240V 60 Hz B � Order Quantity (2) of C400T10. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-177 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control 34 E22 Selector Switch Table 34-203. Type 1, 3R, 4X and 12 E22 Style Combination Starter Cover Control Description Factory Field Installation Kits � Installed Position 9 Combination Cover Control Only Code Catalog Price Number U.S. $ Non-reversing No Cover Mounted Pilot Devices A — START/STOP Pushbuttons (PB) B CE400T01 � START/STOP PB & Red RUN Light C CE400T02 � START/STOP PB, Red RUN, & Green STOPPED Light D CE400T03 HAND/OFF/AUTO Selector Switch (SS) H CE400T04 � H-O-A SS & Red RUN Light J CE400T05 � H-O-A SS, Red RUN, & Green STOPPED Light K CE400T06 � Red RUN Pilot Light P CE400T10 � Green Off Pilot Light Q CE400T11 � Red RUN/Green OFF Pilot Light R CE400T12 ON/OFF Selector Switch (SS) S CE400T07 � ON/OFF SS, Red RUN Light T CE400T08 � ON/OFF SS, Red RUN, & Green STOPPED Light U CE400T09 Reversing No Cover Mounted Pilot Devices A — FWD/REV/STOP Pushbuttons (PB) B CE400T50 � FWD/REV/STOP PB + Red FWD & REV Lights C CE400T51 � FWD/REV/STOP PB, Red FWD/REV, & Green STOPPED D CE400T52 FOR/OFF/REV Selector Switch (SS) H CE400T53 � FOR/OFF/REV SS + Red FWD & REV Lights J CE400T54 � FOR/OFF/REV SS, Red FWD/REV, & Green STOPPED K CE400T55 OPEN/OFF/CLOSE Selector Switch (SS) V CE400T56 � OPEN/OFF/CLOSE SS + Red FWD & REV Lights W CE400T57 � OPEN/OFF/CLOSE SS, Red FWD/REV, & Green STOPPED X CE400T58 � To include any of the above cover controls, place the control code character in position 9 of your Catalog Number and add Mod Code C29. Example: EXE19B4ADA_-C29. Full voltage non-reversing fusible starter with START/STOP pushbutton with red RUN and green OFF pilot lights. � Suffix for lights (required for field installed kits only) in the table below: Rating Code Letter Rating Code Letter Rating Code Letter 120V 60 Hz A 277V 60 Hz H 480V 60 Hz C 208V 60 Hz E 380V 50 Hz L 600V 60 Hz D 240V 60 Hz B Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-178 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Product Selection Table 34-204. Class ECX09 — Non-combination Non-reversing Starter � � Amps Maximum hp Coil Voltage Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame B 7 115 1/4 — 120 ECX09B1AAA-_ ECX09B4AAA-_ ECX09B8AAA-_ XTAE007B10A_ 34 208 3/4 1-1/2 208 ECX09B1EAA-_ ECX09B4EAA-_ ECX09B8EAA-_ XTAE007B10E_ 230 1 2 240 ECX09B1BAA-_ ECX09B4BAA-_ ECX09B8BAA-_ XTAE007B10B_ 380 — 3 380/50 Hz ECX09B1LAA-_ ECX09B4LAA-_ ECX09B8LAA-_ XTAE007B10L_ 460 — 3 480 ECX09B1CAA-_ ECX09B4CAA-_ ECX09B8CAA-_ XTAE007B10C_ 575 — 5 600 ECX09B1DAA-_ ECX09B4DAA-_ ECX09B8DAA-_ XTAE007B10D_ Frame C 9 115 1/2 — 120 ECX09C1AAA-_ ECX09C4AAA-_ ECX09C8AAA-_ XTAE009B10A_ 208 1 2 208 ECX09C1EAA-_ ECX09C4EAA-_ ECX09C8EAA-_ XTAE009B10E_ 230 1-1/2 3 240 ECX09C1BAA-_ ECX09C4BAA-_ ECX09C8BAA-_ XTAE009B10B_ 380 — 5 380/50 Hz ECX09C1LAA-_ ECX09C4LAA-_ ECX09C8LAA-_ XTAE009B10L_ 460 — 5 480 ECX09C1CAA-_ ECX09C4CAA-_ ECX09C8CAA-_ XTAE009B10C_ 575 — 7-1/2 600 ECX09C1DAA-_ ECX09C4DAA-_ ECX09C8DAA-_ XTAE009B10D_ Frame D 12 115 1/2 — 120 ECX09D1AAA-_ ECX09D4AAA-_ ECX09D8AAA-_ XTAE012B10A_ 208 1-1/2 3 208 ECX09D1EAA-_ ECX09D4EAA-_ ECX09D8EAA-_ XTAE012B10E_ 230 2 3 240 ECX09D1BAA-_ ECX09D4BAA-_ ECX09D8BAA-_ XTAE012B10B_ 380 — 5 380/50 Hz ECX09D1LAA-_ ECX09D4LAA-_ ECX09D8LAA-_ XTAE012B10L_ 460 — 7-1/2 480 ECX09D1CAA-_ ECX09D4CAA-_ ECX09D8CAA-_ XTAE012B10C_ 575 — 10 600 ECX09D1DAA-_ ECX09D4DAA-_ ECX09D8DAA-_ XTAE012B10D_ Frame E 15 115 3/4 — 120 ECX09E1AAA-_ ECX09E4AAA-_ ECX09E8AAA-_ XTAE015B10A_ 208 2 3 208 ECX09E1EAA-_ ECX09E4EAA-_ ECX09E8EAA-_ XTAE015B10E_ 230 2 3 240 ECX09E1BAA-_ ECX09E4BAA-_ ECX09E8BAA-_ XTAE015B10B_ 380 — 5 380/50 Hz ECX09E1LAA-_ ECX09E4LAA-_ ECX09E8LAA-_ XTAE015B10L_ 460 — 7-1/2 480 ECX09E1CAA-_ ECX09E4CAA-_ ECX09E8CAA-_ XTAE015B10C_ 575 — 10 600 ECX09E1DAA-_ ECX09E4DAA-_ ECX09E8DAA-_ XTAE015B10D_ Frame F 18 115 2 — 120 ECX09F1AAA-_ ECX09F4AAA-_ ECX09F8AAA-_ XTAE018C10A_ 208 2 5 208 ECX09F1EAA-_ ECX09F4EAA-_ ECX09F8EAA-_ XTAE018C10E_ 230 3 5 240 ECX09F1BAA-_ ECX09F4BAA-_ ECX09F8BAA-_ XTAE018C10B_ 380 — 7-1/2 380/50 Hz ECX09F1LAA-_ ECX09F4LAA-_ ECX09F8LAA-_ XTAE018C10L_ 460 — 10 480 ECX09F1CAA-_ ECX09F4CAA-_ ECX09F8CAA-_ XTAE018C10C_ 575 — 15 600 ECX09F1DAA-_ ECX09F4DAA-_ ECX09F8DAA-_ XTAE018C10D_ Frame G 25 115 2 — 120 ECX09G1AAA-_ ECX09G4AAA-_ ECX09G8AAA-_ XTAE025C10A_ 208 3 7-1/2 208 ECX09G1EAA-_ ECX09G4EAA-_ ECX09G8EAA-_ XTAE025C10E_ 230 5 7-1/2 240 ECX09G1BAA-_ ECX09G4BAA-_ ECX09G8BAA-_ XTAE025C10B_ 380 — 10 380/50 Hz ECX09G1LAA-_ ECX09G4LAA-_ ECX09G8LAA-_ XTAE025C10L_ 460 — 15 480 ECX09G1CAA-_ ECX09G4CAA-_ ECX09G8CAA-_ XTAE025C10C_ 575 — 10 600 ECX09G1DAA-_ ECX09G4DAA-_ ECX09G8DAA-_ XTAE025C10D_ Frame H 32 115 3 — 120 ECX09H1AAA-_ ECX09H4AAA-_ ECX09H8AAA-_ XTAE032C10A_ 208 5 10 208 ECX09H1EAA-_ ECX09H4EAA-_ ECX09H8EAA-_ XTAE032C10E_ 230 5 10 240 ECX09H1BAA-_ ECX09H4BAA-_ ECX09H8BAA-_ XTAE032C10B_ 380 — 15 380/50 Hz ECX09H1LAA-_ ECX09H4LAA-_ ECX09H8LAA-_ XTAE032C10L_ 460 — 20 480 ECX09H1CAA-_ ECX09H4CAA-_ ECX09H8CAA-_ XTAE032C10C_ 575 — 25 600 ECX09H1DAA-_ ECX09H4DAA-_ ECX09H8DAA-_ XTAE032C10D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX09B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-179 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-204. Class ECX09 — Non-combination Non-reversing Starter (Continued) � � Amps Maximum hp Coil Voltage Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame J 40 115 3 — 120 ECX09J1AAA-_ ECX09J4AAA-_ ECX09J8AAA-_ XTAE040D00A_ 208 5 10 208 ECX09J1EAA-_ ECX09J4EAA-_ ECX09J8EAA-_ XTAE040D00E_ 230 7-1/2 15 240 ECX09J1BAA-_ ECX09J4BAA-_ ECX09J8BAA-_ XTAE040D00D_ 34 380 — 15 380/50 Hz ECX09J1LAA-_ ECX09J4LAA-_ ECX09J8LAA-_ XTAE040D00L_ 460 — 30 480 ECX09J1CAA-_ ECX09J4CAA-_ ECX09J8CAA-_ XTAE040D00C_ 575 — 40 600 ECX09J1DAA-_ ECX09J4DAA-_ ECX09J8DAA-_ XTAE040D00D_ Frame K 50 115 3 — 120 ECX09K1AAA-_ ECX09K4AAA-_ ECX09K8AAA-_ XTAE050D00A_ 208 7-1/2 15 208 ECX09K1EAA-_ ECX09K4EAA-_ ECX09K8EAA-_ XTAE050D00E_ 230 10 20 240 ECX09K1BAA-_ ECX09K4BAA-_ ECX09K8BAA-_ XTAE050D00B_ 380 — 20 380/50 Hz ECX09K1LAA-_ ECX09K4LAA-_ ECX09K8LAA-_ XTAE050D00L_ 460 — 40 480 ECX09K1CAA-_ ECX09K4CAA-_ ECX09K8CAA-_ XTAE050D00C_ 575 — 50 600 ECX09K1DAA-_ ECX09K4DAA-_ ECX09K8DAA-_ XTAE050D00D_ Frame L 65 115 5 — 120 ECX09L1AAA-_ ECX09L4AAA-_ ECX09L8AAA-_ XTAE065D00A_ 208 10 20 208 ECX09L1EAA-_ ECX09L4EAA-_ ECX09L8EAA-_ XTAE065D00E_ 230 15 25 240 ECX09L1BAA-_ ECX09L4BAA-_ ECX09L8BAA-_ XTAE065D00B_ 380 — 30 380/50 Hz ECX09L1LAA-_ ECX09L4LAA-_ ECX09L8LAA-_ XTAE065D00L_ 460 — 50 480 ECX09L1CAA-_ ECX09L4CAA-_ ECX09L8CAA-_ XTAE065D00C_ 575 — 60 600 ECX09L1DAA-_ ECX09L4DAA-_ ECX09L8DAA-_ XTAE065D00D_ Frame M 80 115 7-1/2 — 120 ECX09M1AAA-_ ECX09M4AAA-_ ECX09M8AAA-_ XTAE080F00A_ 208 15 25 208 ECX09M1EAA-_ ECX09M4EAA-_ ECX09M8EAA-_ XTAE080F00E_ 230 15 30 240 ECX09M1BAA-_ ECX09M4BAA-_ ECX09M8BAA-_ XTAE080F00B_ 380 — 50 380/50 Hz ECX09M1LAA-_ ECX09M4LAA-_ ECX09M8LAA-_ XTAE080F00L_ 460 — 60 480 ECX09M1CAA-_ ECX09M4CAA-_ ECX09M8CAA-_ XTAE080F00C_ 575 — 75 600 ECX09M1DAA-_ ECX09M4DAA-_ ECX09M8DAA-_ XTAE080F00D_ Frame N 95 115 7-1/2 — 120 ECX09N1AAA-_ ECX09N4AAA-_ ECX09N8AAA-_ XTAE095F00A_ 208 15 25 208 ECX09N1EAA-_ ECX09N4EAA-_ ECX09N8EAA-_ XTAE095F00E_ 230 15 40 240 ECX09N1BAA-_ ECX09N4BAA-_ ECX09N8BAA-_ XTAE095F00B_ 380 — 60 380/50 Hz ECX09N1LAA-_ ECX09N4LAA-_ ECX09N8LAA-_ XTAE095F00L_ 460 — 75 480 ECX09N1CAA-_ ECX09N4CAA-_ ECX09N8CAA-_ XTAE095F00C_ 575 — 100 600 ECX09N1DAA-_ ECX09N4DAA-_ ECX09N8DAA-_ XTAE095F00D_ Frame P 115 115 10 — 120 ECX09P1AAA-_ ECX09P4AAA-_ ECX09P8AAA-_ XTAE115G00A_ 208 25 40 208 ECX09P1EAA-_ ECX09P4EAA-_ ECX09P8EAA-_ XTAE115G00E_ 230 25 50 240 ECX09P1BAA-_ ECX09P4BAA-_ ECX09P8BAA-_ XTAE115G00B_ 380 — 60 380/50 Hz ECX09P1LAA-_ ECX09P4LAA-_ ECX09P8LAA-_ XTAE115G00L_ 460 — 100 480 ECX09P1CAA-_ ECX09P4CAA-_ ECX09P8CAA-_ XTAE115G00C_ 575 — 125 600 ECX09P1DAA-_ ECX09P4DAA-_ ECX09P8DAA-_ XTAE115G00D_ Frame Q 150 115 15 — 120 ECX09Q1AAA-_ ECX09Q4AAA-_ ECX09Q8AAA-_ XTAE150G00A_ 208 25 40 208 ECX09Q1EAA-_ ECX09Q4EAA-_ ECX09Q8EAA-_ XTAE150G00E_ 230 30 60 240 ECX09Q1BAA-_ ECX09Q4BAA-_ ECX09Q8BAA-_ XTAE150G00B_ 380 — 60 380/50 Hz ECX09Q1LAA-_ ECX09Q4LAA-_ ECX09Q8LAA-_ XTAE150G00L_ 460 — 125 480 ECX09Q1CAA-_ ECX09Q4CAA-_ ECX09Q8CAA-_ XTAE150G00C_ 575 — 150 600 ECX09Q1DAA-_ ECX09Q4DAA-_ ECX09Q8DAA-_ XTAE150G00D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX10B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-180 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-205. Class ECX10 — Non-combination Reversing Starter � � Amps Maximum hp Coil Voltage Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame B 7 115 1/4 — 120 ECX10B1AAA-_ ECX10B4AAA-_ ECX10B8AAA-_ XTAR007B10A_ 208 3/4 1-1/2 208 ECX10B1EAA-_ ECX10B4EAA-_ ECX10B8EAA-_ XTAR007B10E_ 230 1 2 240 ECX10B1BAA-_ ECX10B4BAA-_ ECX10B8BAA-_ XTAR007B10B_ 34 380 — 3 380/50 Hz ECX10B1LAA-_ ECX10B4LAA-_ ECX10B8LAA-_ XTAR007B10L_ 460 — 3 480 ECX10B1CAA-_ ECX10B4CAA-_ ECX10B8CAA-_ XTAR007B10C_ 575 — 5 600 ECX10B1DAA-_ ECX10B4DAA-_ ECX10B8DAA-_ XTAR007B10D_ Frame C 9 115 1/2 — 120 ECX10C1AAA-_ ECX10C4AAA-_ ECX10C8AAA-_ XTAR009B10A_ 208 1 2 208 ECX10C1EAA-_ ECX10C4EAA-_ ECX10C8EAA-_ XTAR009B10E_ 230 1-1/2 3 240 ECX10C1BAA-_ ECX10C4BAA-_ ECX10C8BAA-_ XTAR009B10B_ 380 — 5 380/50 Hz ECX10C1LAA-_ ECX10C4LAA-_ ECX10C8LAA-_ XTAR009B10L_ 460 — 5 480 ECX10C1CAA-_ ECX10C4CAA-_ ECX10C8CAA-_ XTAR009B10C_ 575 — 7-1/2 600 ECX10C1DAA-_ ECX10C4DAA-_ ECX10C8DAA-_ XTAR009B10D_ Frame D 12 115 1/2 — 120 ECX10D1AAA-_ ECX10D4AAA-_ ECX10D8AAA-_ XTAR012B10A_ 208 1-1/2 3 208 ECX10D1EAA-_ ECX10D4EAA-_ ECX10D8EAA-_ XTAR012B10E_ 230 2 3 240 ECX10D1BAA-_ ECX10D4BAA-_ ECX10D8BAA-_ XTAR012B10B_ 380 — 5 380/50 Hz ECX10D1LAA-_ ECX10D4LAA-_ ECX10D8LAA-_ XTAR012B10L_ 460 — 7-1/2 480 ECX10D1CAA-_ ECX10D4CAA-_ ECX10D8CAA-_ XTAR012B10C_ 575 — 10 600 ECX10D1DAA-_ ECX10D4DAA-_ ECX10D8DAA-_ XTAR012B10D_ Frame E 15 115 3/4 — 120 ECX10E1AAA-_ ECX10E4AAA-_ ECX10E8AAA-_ XTAR015B10A_ 208 2 3 208 ECX10E1EAA-_ ECX10E4EAA-_ ECX10E8EAA-_ XTAR015B10E_ 230 2 3 240 ECX10E1BAA-_ ECX10E4BAA-_ ECX10E8BAA-_ XTAR015B10B_ 380 — 5 380/50 Hz ECX10E1LAA-_ ECX10E4LAA-_ ECX10E8LAA-_ XTAR015B10L_ 460 — 7-1/2 480 ECX10E1CAA-_ ECX10E4CAA-_ ECX10E8CAA-_ XTAR015B10C_ 575 — 10 600 ECX10E1DAA-_ ECX10E4DAA-_ ECX10E8DAA-_ XTAR015B10D_ Frame F 18 115 2 — 120 ECX10F1AAA-_ ECX10F4AAA-_ ECX10F8AAA-_ XTAR018C10A_ 208 2 5 208 ECX10F1EAA-_ ECX10F4EAA-_ ECX10F8EAA-_ XTAR018C10E_ 230 3 5 240 ECX10F1BAA-_ ECX10F4BAA-_ ECX10F8BAA-_ XTAR018C10B_ 380 — 7-1/2 380/50 Hz ECX10F1LAA-_ ECX10F4LAA-_ ECX10F8LAA-_ XTAR018C10L_ 460 — 10 480 ECX10F1CAA-_ ECX10F4CAA-_ ECX10F8CAA-_ XTAR018C10C_ 575 — 15 600 ECX10F1DAA-_ ECX10F4DAA-_ ECX10F8DAA-_ XTAR018C10D_ Frame G 25 115 2 — 120 ECX10G1AAA-_ ECX10G4AAA-_ ECX10G8AAA-_ XTAR025C10A_ 208 3 7-1/2 208 ECX10G1EAA-_ ECX10G4EAA-_ ECX10G8EAA-_ XTAR025C10E_ 230 5 7-1/2 240 ECX10G1BAA-_ ECX10G4BAA-_ ECX10G8BAA-_ XTAR025C10B_ 380 — 10 380/50 Hz ECX10G1LAA-_ ECX10G4LAA-_ ECX10G8LAA-_ XTAR025C10L_ 460 — 15 480 ECX10G1CAA-_ ECX10G4CAA-_ ECX10G8CAA-_ XTAR025C10C_ 575 — 10 600 ECX10G1DAA-_ ECX10G4DAA-_ ECX10G8DAA-_ XTAR025C10D_ Frame H 32 115 3 — 120 ECX10H1AAA-_ ECX10H4AAA-_ ECX10H8AAA-_ XTAR032C10A_ 208 5 10 208 ECX10H1EAA-_ ECX10H4EAA-_ ECX10H8EAA-_ XTAR032C10E_ 230 5 10 240 ECX10H1BAA-_ ECX10H4BAA-_ ECX10H8BAA-_ XTAR032C10B_ 380 — 15 380/50 Hz ECX10H1LAA-_ ECX10H4LAA-_ ECX10H8LAA-_ XTAR032C10L_ 460 — 20 480 ECX10H1CAA-_ ECX10H4CAA-_ ECX10H8CAA-_ XTAR032C10C_ 575 — 25 600 ECX10H1DAA-_ ECX10H4DAA-_ ECX10H8DAA-_ XTAR032C10D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX10B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-181 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-205. Class ECX10 — Non-combination Reversing Starter (Continued) � � Amps Maximum hp Coil Voltage Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame J 40 115 3 — 120 ECX10J1AAA-_ ECX10J4AAA-_ ECX10J8AAA-_ XTAR040D00A_ 208 5 10 208 ECX10J1EAA-_ ECX10J4EAA-_ ECX10J8EAA-_ XTAR040D00E_ 230 7-1/2 15 240 ECX10J1BAA-_ ECX10J4BAA-_ ECX10J8BAA-_ XTAR040D00B_ 34 380 — 15 380/50 Hz ECX10J1LAA-_ ECX10J4LAA-_ ECX10J8LAA-_ XTAR040D00L_ 460 — 30 480 ECX10J1CAA-_ ECX10J4CAA-_ ECX10J8CAA-_ XTAR040D00C_ 575 — 40 600 ECX10J1DAA-_ ECX10J4DAA-_ ECX10J8DAA-_ XTAR040D00D_ Frame K 50 115 3 — 120 ECX10K1AAA-_ ECX10K4AAA-_ ECX10K8AAA-_ XTAR050D00A_ 208 7-1/2 15 208 ECX10K1EAA-_ ECX10K4EAA-_ ECX10K8EAA-_ XTAR050D00E_ 230 10 20 240 ECX10K1BAA-_ ECX10K4BAA-_ ECX10K8BAA-_ XTAR050D00B_ 380 — 20 380/50 Hz ECX10K1LAA-_ ECX10K4LAA-_ ECX10K8LAA-_ XTAR050D00L_ 460 — 40 480 ECX10K1CAA-_ ECX10K4CAA-_ ECX10K8CAA-_ XTAR050D00C_ 575 — 50 600 ECX10K1DAA-_ ECX10K4DAA-_ ECX10K8DAA-_ XTAR050D00D_ Frame L 65 115 5 — 120 ECX10L1AAA-_ ECX10L4AAA-_ ECX10L8AAA-_ XTAR065D00A_ 208 10 20 208 ECX10L1EAA-_ ECX10L4EAA-_ ECX10L8EAA-_ XTAR065D00E_ 230 15 25 240 ECX10L1BAA-_ ECX10L4BAA-_ ECX10L8BAA-_ XTAR065D00B_ 380 — 30 380/50 Hz ECX10L1LAA-_ ECX10L4LAA-_ ECX10L8LAA-_ XTAR065D00L_ 460 — 50 480 ECX10L1CAA-_ ECX10L4CAA-_ ECX10L8CAA-_ XTAR065D00C_ 575 — 60 600 ECX10L1DAA-_ ECX10L4DAA-_ ECX10L8DAA-_ XTAR065D00D_ Frame M 80 115 7-1/2 — 120 ECX10M1AAA-_ ECX10M4AAA-_ ECX10M8AAA-_ XTAR080F00A_ 208 15 25 208 ECX10M1EAA-_ ECX10M4EAA-_ ECX10M8EAA-_ XTAR080F00E_ 230 15 30 240 ECX10M1BAA-_ ECX10M4BAA-_ ECX10M8BAA-_ XTAR080F00B_ 380 — 50 380/50 Hz ECX10M1LAA-_ ECX10M4LAA-_ ECX10M8LAA-_ XTAR080F00L_ 460 — 60 480 ECX10M1CAA-_ ECX10M4CAA-_ ECX10M8CAA-_ XTAR080F00C_ 575 — 75 600 ECX10M1DAA-_ ECX10M4DAA-_ ECX10M8DAA-_ XTAR080F00D_ Frame N 95 115 7-1/2 — 120 ECX10N1AAA-_ ECX10N4AAA-_ ECX10N8AAA-_ XTAR095F00A_ 208 15 25 208 ECX10N1EAA-_ ECX10N4EAA-_ ECX10N8EAA-_ XTAR095F00E_ 230 15 40 240 ECX10N1BAA-_ ECX10N4BAA-_ ECX10N8BAA-_ XTAR095F00B_ 380 — 60 380/50 Hz ECX10N1LAA-_ ECX10N4LAA-_ ECX10N8LAA-_ XTAR095F00L_ 460 — 75 480 ECX10N1CAA-_ ECX10N4CAA-_ ECX10N8CAA-_ XTAR095F00C_ 575 — 100 600 ECX10N1DAA-_ ECX10N4DAA-_ ECX10N8DAA-_ XTAR095F00D_ Frame P 115 115 10 — 120 ECX10P1AAA-_ ECX10P4AAA-_ ECX10P8AAA-_ XTAR115G00A_ 208 25 40 208 ECX10P1EAA-_ ECX10P4EAA-_ ECX10P8EAA-_ XTAR115G00E_ 230 25 50 240 ECX10P1BAA-_ ECX10P4BAA-_ ECX10P8BAA-_ XTAR115G00B_ 380 — 60 380/50 Hz ECX10P1LAA-_ ECX10P4LAA-_ ECX10P8LAA-_ XTAR115G00L_ 460 — 100 480 ECX10P1CAA-_ ECX10P4CAA-_ ECX10P8CAA-_ XTAR115G00C_ 575 — 125 600 ECX10P1DAA-_ ECX10P4DAA-_ ECX10P8DAA-_ XTAR115G00D_ Frame Q 150 115 15 — 120 ECX10Q1AAA-_ ECX10Q4AAA-_ ECX10Q8AAA-_ XTAR150G00A_ 208 25 40 208 ECX10Q1EAA-_ ECX10Q4EAA-_ ECX10Q8EAA-_ XTAR150G00E_ 230 30 60 240 ECX10Q1BAA-_ ECX10Q4BAA-_ ECX10Q8BAA-_ XTAR150G00B_ 380 — 60 380/50 Hz ECX10Q1LAA-_ ECX10Q4LAA-_ ECX10Q8LAA-_ XTAR150G00L_ 460 — 125 480 ECX10Q1CAA-_ ECX10Q4CAA-_ ECX10Q8CAA-_ XTAR150G00C_ 575 — 150 600 ECX10Q1DAA-_ ECX10Q4DAA-_ ECX10Q8DAA-_ XTAR150G00D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX10B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-182 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-206. Class ECX11 — Non-combination Non-reversing Starter with CPT � � Amps Maximum hp Coil Voltage Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame B 7 115 1/4 — 120 ECX11B1AAA-_ ECX11B4AAA-_ ECX11B8AAA-_ XTAE007B10A_ 208 3/4 1-1/2 208 ECX11B1EAA-_ ECX11B4EAA-_ ECX11B8EAA-_ XTAE007B10E_ 230 1 2 240 ECX11B1BAA-_ ECX11B4BAA-_ ECX11B8BAA-_ XTAE007B10B_ 34 380 — 3 380/50 Hz ECX11B1LAA-_ ECX11B4LAA-_ ECX11B8LAA-_ XTAE007B10L_ 460 — 3 480 ECX11B1CAA-_ ECX11B4CAA-_ ECX11B8CAA-_ XTAE007B10C_ 575 — 5 600 ECX11B1DAA-_ ECX11B4DAA-_ ECX11B8DAA-_ XTAE007B10D_ Frame C 9 115 1/2 — 120 ECX11C1AAA-_ ECX11C4AAA-_ ECX11C8AAA-_ XTAE009B10A_ 208 1 2 208 ECX11C1EAA-_ ECX11C4EAA-_ ECX11C8EAA-_ XTAE009B10E_ 230 1-1/2 3 240 ECX11C1BAA-_ ECX11C4BAA-_ ECX11C8BAA-_ XTAE009B10B_ 380 — 5 380/50 Hz ECX11C1LAA-_ ECX11C4LAA-_ ECX11C8LAA-_ XTAE009B10L_ 460 — 5 480 ECX11C1CAA-_ ECX11C4CAA-_ ECX11C8CAA-_ XTAE009B10C_ 575 — 7-1/2 600 ECX11C1DAA-_ ECX11C4DAA-_ ECX11C8DAA-_ XTAE009B10D_ Frame D 12 115 1/2 — 120 ECX11D1AAA-_ ECX11D4AAA-_ ECX11D8AAA-_ XTAE012B10A_ 208 1-1/2 3 208 ECX11D1EAA-_ ECX11D4EAA-_ ECX11D8EAA-_ XTAE012B10E_ 230 2 3 240 ECX11D1BAA-_ ECX11D4BAA-_ ECX11D8BAA-_ XTAE012B10B_ 380 — 5 380/50 Hz ECX11D1LAA-_ ECX11D4LAA-_ ECX11D8LAA-_ XTAE012B10L_ 460 — 7-1/2 480 ECX11D1CAA-_ ECX11D4CAA-_ ECX11D8CAA-_ XTAE012B10C_ 575 — 10 600 ECX11D1DAA-_ ECX11D4DAA-_ ECX11D8DAA-_ XTAE012B10D_ Frame E 15 115 3/4 — 120 ECX11E1AAA-_ ECX11E4AAA-_ ECX11E8AAA-_ XTAE015B10A_ 208 2 3 208 ECX11E1EAA-_ ECX11E4EAA-_ ECX11E8EAA-_ XTAE015B10E_ 230 2 3 240 ECX11E1BAA-_ ECX11E4BAA-_ ECX11E8BAA-_ XTAE015B10B_ 380 — 5 380/50 Hz ECX11E1LAA-_ ECX11E4LAA-_ ECX11E8LAA-_ XTAE015B10L_ 460 — 7-1/2 480 ECX11E1CAA-_ ECX11E4CAA-_ ECX11E8CAA-_ XTAE015B10C_ 575 — 10 600 ECX11E1DAA-_ ECX11E4DAA-_ ECX11E8DAA-_ XTAE015B10D_ Frame F 18 115 2 — 120 ECX11F1AAA-_ ECX11F4AAA-_ ECX11F8AAA-_ XTAE018C10A_ 208 2 5 208 ECX11F1EAA-_ ECX11F4EAA-_ ECX11F8EAA-_ XTAE018C10E_ 230 3 5 240 ECX11F1BAA-_ ECX11F4BAA-_ ECX11F8BAA-_ XTAE018C10B_ 380 — 7-1/2 380/50 Hz ECX11F1LAA-_ ECX11F4LAA-_ ECX11F8LAA-_ XTAE018C10L_ 460 — 10 480 ECX11F1CAA-_ ECX11F4CAA-_ ECX11F8CAA-_ XTAE018C10C_ 575 — 15 600 ECX11F1DAA-_ ECX11F4DAA-_ ECX11F8DAA-_ XTAE018C10D_ Frame G 25 115 2 — 120 ECX11G1AAA-_ ECX11G4AAA-_ ECX11G8AAA-_ XTAE025C10A_ 208 3 7-1/2 208 ECX11G1EAA-_ ECX11G4EAA-_ ECX11G8EAA-_ XTAE025C10E_ 230 5 7-1/2 240 ECX11G1BAA-_ ECX11G4BAA-_ ECX11G8BAA-_ XTAE025C10B_ 380 — 10 380/50 Hz ECX11G1LAA-_ ECX11G4LAA-_ ECX11G8LAA-_ XTAE025C10L_ 460 — 15 480 ECX11G1CAA-_ ECX11G4CAA-_ ECX11G8CAA-_ XTAE025C10C_ 575 — 20 600 ECX11G1DAA-_ ECX11G4DAA-_ ECX11G8DAA-_ XTAE025C10D_ Frame H 32 115 3 — 120 ECX11H1AAA-_ ECX11H4AAA-_ ECX11H8AAA-_ XTAE032C10A_ 208 5 10 208 ECX11H1EAA-_ ECX11H4EAA-_ ECX11H8EAA-_ XTAE032C10E_ 230 5 10 240 ECX11H1BAA-_ ECX11H4BAA-_ ECX11H8BAA-_ XTAE032C10B_ 380 — 15 380/50 Hz ECX11H1LAA-_ ECX11H4LAA-_ ECX11H8LAA-_ XTAE032C10L_ 460 — 20 480 ECX11H1CAA-_ ECX11H4CAA-_ ECX11H8CAA-_ XTAE032C10C_ 575 — 25 600 ECX11H1DAA-_ ECX11H4DAA-_ ECX11H8DAA-_ XTAE032C10D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX11B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-183 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-206. Class ECX11 — Non-combination Non-reversing Starter with CPT (Continued) � � Amps Maximum hp Coil Voltage Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame J 40 115 3 — 120 ECX11J1AAA-_ ECX11J4AAA-_ ECX11J8AAA-_ XTAE040D00A_ 208 5 10 208 ECX11J1EAA-_ ECX11J4EAA-_ ECX11J8EAA-_ XTAE040D00E_ 230 7-1/2 15 240 ECX11J1BAA-_ ECX11J4BAA-_ ECX11J8BAA-_ XTAE040D00B_ 34 380 — 15 380/50 Hz ECX11J1LAA-_ ECX11J4LAA-_ ECX11J8LAA-_ XTAE040D00L_ 460 — 30 480 ECX11J1CAA-_ ECX11J4CAA-_ ECX11J8CAA-_ XTAE040D00C_ 575 — 40 600 ECX11J1DAA-_ ECX11J4DAA-_ ECX11J8DAA-_ XTAE040D00D_ Frame K 50 115 3 — 120 ECX11K1AAA-_ ECX11K4AAA-_ ECX11K8AAA-_ XTAE050D00A_ 208 7-1/2 15 208 ECX11K1EAA-_ ECX11K4EAA-_ ECX11K8EAA-_ XTAE050D00E_ 230 10 20 240 ECX11K1BAA-_ ECX11K4BAA-_ ECX11K8BAA-_ XTAE050D00B_ 380 — 20 380/50 Hz ECX11K1LAA-_ ECX11K4LAA-_ ECX11K8LAA-_ XTAE050D00L_ 460 — 40 480 ECX11K1CAA-_ ECX11K4CAA-_ ECX11K8CAA-_ XTAE050D00C_ 575 — 50 600 ECX11K1DAA-_ ECX11K4DAA-_ ECX11K8DAA-_ XTAE050D00D_ Frame L 65 115 5 — 120 ECX11L1AAA-_ ECX11L4AAA-_ ECX11L8AAA-_ XTAE065D00A_ 208 10 20 208 ECX11L1EAA-_ ECX11L4EAA-_ ECX11L8EAA-_ XTAE065D00E_ 230 15 25 240 ECX11L1BAA-_ ECX11L4BAA-_ ECX11L8BAA-_ XTAE065D00B_ 380 — 30 380/50 Hz ECX11L1LAA-_ ECX11L4LAA-_ ECX11L8LAA-_ XTAE065D00L_ 460 — 50 480 ECX11L1CAA-_ ECX11L4CAA-_ ECX11L8CAA-_ XTAE065D00C_ 575 — 60 600 ECX11L1DAA-_ ECX11L4DAA-_ ECX11L8DAA-_ XTAE065D00D_ Frame M 80 115 7-1/2 — 120 ECX11M1AAA-_ ECX11M4AAA-_ ECX11M8AAA-_ XTAE080F00A_ 208 15 25 208 ECX11M1EAA-_ ECX11M4EAA-_ ECX11M8EAA-_ XTAE080F00E_ 230 15 30 240 ECX11M1BAA-_ ECX11M4BAA-_ ECX11M8BAA-_ XTAE080F00B_ 380 — 50 380/50 Hz ECX11M1LAA-_ ECX11M4LAA-_ ECX11M8LAA-_ XTAE080F00L_ 460 — 60 480 ECX11M1CAA-_ ECX11M4CAA-_ ECX11M8CAA-_ XTAE080F00C_ 575 — 75 600 ECX11M1DAA-_ ECX11M4DAA-_ ECX11M8DAA-_ XTAE080F00D_ Frame N 95 115 7-1/2 — 120 ECX11N1AAA-_ ECX11N4AAA-_ ECX11N8AAA-_ XTAE095F00A_ 208 15 25 208 ECX11N1EAA-_ ECX11N4EAA-_ ECX11N8EAA-_ XTAE095F00E_ 230 15 40 240 ECX11N1BAA-_ ECX11N4BAA-_ ECX11N8BAA-_ XTAE095F00B_ 380 — 60 380/50 Hz ECX11N1LAA-_ ECX11N4LAA-_ ECX11N8LAA-_ XTAE095F00L_ 460 — 75 480 ECX11N1CAA-_ ECX11N4CAA-_ ECX11N8CAA-_ XTAE095F00C_ 575 — 100 600 ECX11N1DAA-_ ECX11N4DAA-_ ECX11N8DAA-_ XTAE095F00D_ Frame P 115 115 10 — 120 ECX11P1AAA-_ ECX11P4AAA-_ ECX11P8AAA-_ XTAE115G00A_ 208 25 40 208 ECX11P1EAA-_ ECX11P4EAA-_ ECX11P8EAA-_ XTAE115G00E_ 230 25 50 240 ECX11P1BAA-_ ECX11P4BAA-_ ECX11P8BAA-_ XTAE115G00B_ 380 — 60 380/50 Hz ECX11P1LAA-_ ECX11P4LAA-_ ECX11P8LAA-_ XTAE115G00L_ 460 — 100 480 ECX11P1CAA-_ ECX11P4CAA-_ ECX11P8CAA-_ XTAE115G00C_ 575 — 125 600 ECX11P1DAA-_ ECX11P4DAA-_ ECX11P8DAA-_ XTAE115G00D_ Frame Q 150 115 15 — 120 ECX11Q1AAA-_ ECX11Q4AAA-_ ECX11Q8AAA-_ XTAE150G00A_ 208 25 40 208 ECX11Q1EAA-_ ECX11Q4EAA-_ ECX11Q8EAA-_ XTAE150G00E_ 230 30 60 240 ECX11Q1BAA-_ ECX11Q4BAA-_ ECX11Q8BAA-_ XTAE150G00B_ 380 — 60 380/50 Hz ECX11Q1LAA-_ ECX11Q4LAA-_ ECX11Q8LAA-_ XTAE150G00L_ 460 — 125 480 ECX11Q1CAA-_ ECX11Q4CAA-_ ECX11Q8CAA-_ XTAE150G00C_ 575 — 150 600 ECX11Q1DAA-_ ECX11Q4DAA-_ ECX11Q8DAA-_ XTAE150G00D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX11B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-184 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-207. Class ECX19 — Combination Non-reversing Starter — Fusible/Non-fusible Disconnect � � Amps Maximum hp Coil Voltage Fuse Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Clips Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame B 7— — — — 30A ECX19B1AAA-_ ECX19B4AAA-_ ECX19B8AAA-_ XTAE007B10A_ 115 1/4 — 120 ECX19B1AAC-_ ECX19B4AAC-_ ECX19B8AAC-_ XTAE007B10A_ 208 3/4 1-1/2 208 ECX19B1EAC-_ ECX19B4EAC-_ ECX19B8EAC-_ XTAE007B10E_ 230 1 2 240 ECX19B1BAC-_ ECX19B4BAC-_ ECX19B8BAC-_ XTAE007B10B_ 34 380 — 3 380/50 Hz ECX19B1LAC-_ ECX19B4LAC-_ ECX19B8LAC-_ XTAE007B10L_ 460 — 3 480 ECX19B1CAC-_ ECX19B4CAC-_ ECX19B8CAC-_ XTAE007B10C_ 575 — 5 600 ECX19B1DAC-_ ECX19B4DAC-_ ECX19B8DAC-_ XTAE007B10D_ Frame C 9— — — — 30A ECX19C1AAA-_ ECX19C4AAA-_ ECX19C8AAA-_ XTAE009B10A_ 115 1/2 — 120 ECX19C1AAC-_ ECX19C4AAC-_ ECX19C8AAC-_ XTAE009B10A_ 208 1 2 208 ECX19C1EAC-_ ECX19C4EAC-_ ECX19C8EAC-_ XTAE009B10E_ 230 1-1/2 3 240 ECX19C1BAC-_ ECX19C4BAC-_ ECX19C8BAC-_ XTAE009B10B_ 380 — 5 380/50 Hz ECX19C1LAC-_ ECX19C4LAC-_ ECX19C8LAC-_ XTAE009B10L_ 460 — 5 480 ECX19C1CAC-_ ECX19C4CAC-_ ECX19C8CAC-_ XTAE009B10C_ 575 — 7-1/2 600 ECX19C1DAC-_ ECX19C4DAC-_ ECX19C8DAC-_ XTAE009B10D_ Frame D 12 — — — — 30A ECX19D1AAA-_ ECX19D4AAA-_ ECX19D8AAA-_ XTAE012B10A_ 115 1/2 — 120 ECX19D1AAC-_ ECX19D4AAC-_ ECX19D8AAC-_ XTAE012B10A_ 208 1-1/2 3 208 ECX19D1EAC-_ ECX19D4EAC-_ ECX19D8EAC-_ XTAE012B10E_ 230 2 3 240 ECX19D1BAC-_ ECX19D4BAC-_ ECX19D8BAC-_ XTAE012B10B_ 380 — 5 380/50 Hz ECX19D1LAC-_ ECX19D4LAC-_ ECX19D8LAC-_ XTAE012B10L_ 460 — 7-1/2 480 ECX19D1CAC-_ ECX19D4CAC-_ ECX19D8CAC-_ XTAE012B10C_ 575 — 10 600 ECX19D1DAC-_ ECX19D4DAC-_ ECX19D8DAC-_ XTAE012B10D_ Frame E 15 — — — — 30A ECX19E1AAA-_ ECX19E4AAA-_ ECX19E8AAA-_ XTAE015B10A_ 115 3/4 — 120 ECX19E1AAC-_ ECX19E4AAC-_ ECX19E8AAC-_ XTAE015B10A_ 208 2 3 208 ECX19E1EAC-_ ECX19E4EAC-_ ECX19E8EAC-_ XTAE015B10E_ 230 2 3 240 ECX19E1BAC-_ ECX19E4BAC-_ ECX19E8BAC-_ XTAE015B10B_ 380 — 5 380/50 Hz ECX19E1LAC-_ ECX19E4LAC-_ ECX19E8LAC-_ XTAE015B10L_ 460 — 7-1/2 480 ECX19E1CAC-_ ECX19E4CAC-_ ECX19E8CAC-_ XTAE015B10C_ 575 — 10 600 ECX19E1DAC-_ ECX19E4DAC-_ ECX19E8DAC-_ XTAE015B10D_ Frame F 18 — — — — 30A ECX19F1AAA-_ ECX19F4AAA-_ ECX19F8AAA-_ XTAE018C10A_ 115 2 — 120 ECX19F1AAC-_ ECX19F4AAC-_ ECX19F8AAC-_ XTAE018C10A_ 208 2 5 208 ECX19F1EAC-_ ECX19F4EAC-_ ECX19F8EAC-_ XTAE018C10E_ 230 3 5 240 ECX19F1BAC-_ ECX19F4BAC-_ ECX19F8BAC-_ XTAE018C10B_ 380 — 7-1/2 380/50 Hz ECX19F1LAC-_ ECX19F4LAC-_ ECX19F8LAC-_ XTAE018C10L_ 460 — 10 480 ECX19F1CAC-_ ECX19F4CAC-_ ECX19F8CAC-_ XTAE018C10C_ 575 — 15 600 ECX19F1DAC-_ ECX19F4DAC-_ ECX19F8DAC-_ XTAE018C10D_ Frame G 25 — — — — 30A ECX19G1AAA-_ ECX19G4AAA-_ ECX19G8AAA-_ XTAE025C10A_ 115 2 — 120 ECX19G1AAC-_ ECX19G4AAC-_ ECX19G8AAC-_ XTAE025C10A_ 208 3 7-1/2 208 ECX19G1EAC-_ ECX19G4EAC-_ ECX19G8EAC-_ XTAE025C10E_ 230 5 7-1/2 240 ECX19G1BAC-_ ECX19G4BAC-_ ECX19G8BAC-_ XTAE025C10B_ 380 — 10 380/50 Hz ECX19G1LAC-_ ECX19G4LAC-_ ECX19G8LAC-_ XTAE025C10L_ 460 — 15 480 ECX19G1CAC-_ ECX19G4CAC-_ ECX19G8CAC-_ XTAE025C10C_ 575 — 10 600 ECX19G1DAC-_ ECX19G4DAC-_ ECX19G8DAC-_ XTAE025C10D_ Frame H 32 — — — — 60A ECX19H1AAA-_ ECX19H4AAA-_ ECX19H8AAA-_ XTAE032C10A_ 115 3 — 120 ECX19H1AAE-_ ECX19H4AAE-_ ECX19H8AAE-_ XTAE032C10A_ 208 5 10 208 ECX19H1EAE-_ ECX19H4EAE-_ ECX19H8EAE-_ XTAE032C10E_ 230 5 10 240 ECX19H1BAE-_ ECX19H4BAE-_ ECX19H8BAE-_ XTAE032C10B_ 380 — 15 380/50 Hz ECX19H1LAE-_ ECX19H4LAE-_ ECX19H8LAE-_ XTAE032C10L_ 460 — 20 480 ECX19H1CAE-_ ECX19H4CAE-_ ECX19H8CAE-_ XTAE032C10C_ 575 — 25 600 ECX19H1DAE-_ ECX19H4DAE-_ ECX19H8DAE-_ XTAE032C10D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX19B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-185 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-207. Class ECX19 — Combination Non-reversing Starter — Fusible/Non-fusible Disconnect (Continued) � � Amps Maximum hp Coil Voltage Fuse Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Clips Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame J 40 — — — — 60A ECX19J1AAA-_ ECX19J4AAA-_ ECX19J8AAA-_ XTAE040D00A_ 115 3 — 120 ECX19J1AAE-_ ECX19J4AAE-_ ECX19J8AAE-_ XTAE040D00A_ 208 5 10 208 ECX19J1EAE-_ ECX19J4EAE-_ ECX19J8EAE-_ XTAE040D00E_ 34 230 7-1/2 15 240 ECX19J1BAE-_ ECX19J4BAE-_ ECX19J8BAE-_ XTAE040D00B_ 380 — 15 380/50 Hz ECX19J1LAE-_ ECX19J4LAE-_ ECX19J8LAE-_ XTAE040D00L_ 460 — 30 480 ECX19J1CAE-_ ECX19J4CAE-_ ECX19J8CAE-_ XTAE040D00C_ 575 — 40 600 ECX19J1DAE-_ ECX19J4DAE-_ ECX19J8DAE-_ XTAE040D00D_ Frame K 50 — — — — 100A ECX19K1AAA-_ ECX19K4AAA-_ ECX19K8AAA-_ XTAE050D00A_ 115 3 — 120 ECX19K1AAG-_ ECX19K4AAG-_ ECX19K8AAG-_ XTAE050D00A_ 208 7-1/2 15 208 ECX19K1EAG-_ ECX19K4EAG-_ ECX19K8EAG-_ XTAE050D00E_ 230 10 20 240 ECX19K1BAG-_ ECX19K4BAG-_ ECX19K8BAG-_ XTAE050D00B_ 380 — 20 380/50 Hz ECX19K1LAG-_ ECX19K4LAG-_ ECX19K8LAG-_ XTAE050D00L_ 460 — 40 480 ECX19K1CAG-_ ECX19K4CAG-_ ECX19K8CAG-_ XTAE050D00C_ 575 — 50 600 ECX19K1DAG-_ ECX19K4DAG-_ ECX19K8DAG-_ XTAE050D00D_ Frame L 65 — — — — 100A ECX19L1AAA-_ ECX19L4AAA-_ ECX19L8AAA-_ XTAE065D00A_ 115 5 — 120 ECX19L1AAG-_ ECX19L4AAG-_ ECX19L8AAG-_ XTAE065D00A_ 208 10 20 208 ECX19L1EAG-_ ECX19L4EAG-_ ECX19L8EAG-_ XTAE065D00E_ 230 15 25 240 ECX19L1BAG-_ ECX19L4BAG-_ ECX19L8BAG-_ XTAE065D00B_ 380 — 30 380/50 Hz ECX19L1LAG-_ ECX19L4LAG-_ ECX19L8LAG-_ XTAE065D00L_ 460 — 50 480 ECX19L1CAG-_ ECX19L4CAG-_ ECX19L8CAG-_ XTAE065D00C_ 575 — 60 600 ECX19L1DAG-_ ECX19L4DAG-_ ECX19L8DAG-_ XTAE065D00D_ Frame M 80— — — — 100A ECX19M1AAA-_ ECX19M4AAA-_ ECX19M8AAA-_ XTAE080F00A_ 115 7-1/2 — 120 ECX19M1AAG-_ ECX19M4AAG-_ ECX19M8AAG-_ XTAE080F00A_ 208 15 25 208 ECX19M1EAG-_ ECX19M4EAG-_ ECX19M8EAG-_ XTAE080F00E_ 230 15 30 240 ECX19M1BAG-_ ECX19M4BAG-_ ECX19M8BAG-_ XTAE080F00B_ 380 — 50 380/50 Hz ECX19M1LAG-_ ECX19M4LAG-_ ECX19M8LAG-_ XTAE080F00L_ 460 — 60 480 ECX19M1CAG-_ ECX19M4CAG-_ ECX19M8CAG-_ XTAE080F00C_ 575 — 75 600 ECX19M1DAG-_ ECX19M4DAG-_ ECX19M8DAG-_ XTAE080F00D_ � Frame N � 95 — — — — ECX19N1AAA-_ ECX19N4AAA-_ ECX19N8AAA-_ XTAE095F00A_ 115 7-1/2 — 120 ECX19N1AAH-_ ECX19N4AAH-_ ECX19N8AAH-_ XTAE095F00A_ 208 15 25 208 ECX19N1EAH-_ ECX19N4EAH-_ ECX19N8EAH-_ XTAE095F00E_ 230 15 40 240 ECX19N1BAH-_ ECX19N4BAH-_ ECX19N8BAH-_ XTAE095F00B_ 380 — 60 380/50 Hz ECX19N1LAH-_ ECX19N4LAH-_ ECX19N8LAH-_ XTAE095F00L_ 460 — 75 480 ECX19N1CAH-_ ECX19N4CAH-_ ECX19N8CAH-_ XTAE095F00C_ 575 — 100 600 ECX19N1DAH-_ ECX19N4DAH-_ ECX19N8DAH-_ XTAE095F00D_ � Frame P � 105 — — — — ECX19P1AAA-_ ECX19P4AAA-_ ECX19P8AAA-_ XTAE115G00A_ 115 10 — 120 ECX19P1AAH-_ ECX19P4AAH-_ ECX19P8AAH-_ XTAE115G00A_ 208 25 30 208 ECX19P1EAH-_ ECX19P4EAH-_ ECX19P8EAH-_ XTAE115G00E_ 230 25 40 240 ECX19P1BAH-_ ECX19P4BAH-_ ECX19P8BAH-_ XTAE115G00B_ 380 — 60 380/50 Hz ECX19P1LAH-_ ECX19P4LAH-_ ECX19P8LAH-_ XTAE115G00L_ 460 — 75 480 ECX19P1CAH-_ ECX19P4CAH-_ ECX19P8CAH-_ XTAE115G00C_ 575 — 100 600 ECX19P1DAH-_ ECX19P4DAH-_ ECX19P8DAH-_ XTAE115G00D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX19B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. � Non-fused Disconnect only. Cover Control . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-186 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-208. Class ECX20 — Combination Reversing Starter — Fusible/Non-fusible Disconnect � � Amps Maximum hp Coil Voltage Fuse Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Clips Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame B 7— — — — 30A ECX20B1AAA-_ ECX20B4AAA-_ ECX20B8AAA-_ XTAR007B10A_ 115 1/4 — 120 ECX20B1AAC-_ ECX20B4AAC-_ ECX20B8AAC-_ XTAR007B10A_ 208 3/4 1-1/2 208 ECX20B1EAC-_ ECX20B4EAC-_ ECX20B8EAC-_ XTAR007B10E_ 230 1 2 240 ECX20B1BAC-_ ECX20B4BAC-_ ECX20B8BAC-_ XTAR007B10B_ 34 380 — 3 380/50 Hz ECX20B1LAC-_ ECX20B4LAC-_ ECX20B8LAC-_ XTAR007B10L_ 460 — 3 480 ECX20B1CAC-_ ECX20B4CAC-_ ECX20B8CAC-_ XTAR007B10C_ 575 — 5 600 ECX20B1DAC-_ ECX20B4DAC-_ ECX20B8DAC-_ XTAR007B10D_ Frame C 9— — — — 30A ECX20C1AAA-_ ECX20C4AAA-_ ECX20C8AAA-_ XTAR009B10A_ 115 1/2 — 120 ECX20C1AAC-_ ECX20C4AAC-_ ECX20C8AAC-_ XTAR009B10A_ 208 1 2 208 ECX20C1EAC-_ ECX20C4EAC-_ ECX20C8EAC-_ XTAR009B10E_ 230 1-1/2 3 240 ECX20C1BAC-_ ECX20C4BAC-_ . ECX20C8BAC-_ XTAR009B10B_ 380 — 5 380/50 Hz ECX20C1LAC-_ ECX20C4LAC-_ ECX20C8LAC-_ XTAR009B10L_ 460 — 5 480 ECX20C1CAC-_ ECX20C4CAC-_ ECX20C8CAC-_ XTAR009B10C_ 575 — 7-1/2 600 ECX20C1DAC-_ ECX20C4DAC-_ ECX20C8DAC-_ XTAR009B10D_ Frame D 12 — — — — 30A ECX20D1AAA-_ ECX20D4AAA-_ ECX20D8AAA-_ XTAR012B10A_ 115 1/2 — 120 ECX20D1AAC-_ ECX20D4AAC-_ ECX20D8AAC-_ XTAR012B10A_ 208 1-1/2 3 208 ECX20D1EAC-_ ECX20D4EAC-_ ECX20D8EAC-_ XTAR012B10E_ 230 2 3 240 ECX20D1BAC-_ ECX20D4BAC-_ ECX20D8BAC-_ XTAR012B10B_ 380 — 5 380/50 Hz ECX20D1LAC-_ ECX20D4LAC-_ ECX20D8LAC-_ XTAR012B10L_ 460 — 7-1/2 480 ECX20D1CAC-_ ECX20D4CAC-_ ECX20D8CAC-_ XTAR012B10C_ 575 — 10 600 ECX20D1DAC-_ ECX20D4DAC-_ ECX20D8DAC-_ XTAR012B10D_ Frame E 15 — — — — 30A ECX20E1AAA-_ ECX20E4AAA-_ ECX20E8AAA-_ XTAR015B10A_ 115 3/4 — 120 ECX20E1AAC-_ ECX20E4AAC-_ ECX20E8AAC-_ XTAR015B10A_ 208 2 3 208 ECX20E1EAC-_ ECX20E4EAC-_ ECX20E8EAC-_ XTAR015B10E_ 230 2 3 240 ECX20E1BAC-_ ECX20E4BAC-_ ECX20E8BAC-_ XTAR015B10B_ 380 — 5 380/50 Hz ECX20E1LAC-_ ECX20E4LAC-_ ECX20E8LAC-_ XTAR015B10L_ 460 — 7-1/2 480 ECX20E1CAC-_ ECX20E4CAC-_ ECX20E8CAC-_ XTAR015B10C_ 575 — 10 600 ECX20E1DAC-_ ECX20E4DAC-_ ECX20E8DAC-_ XTAR015B10D_ Frame F 18 — — — — 30A ECX20F1AAA-_ ECX20F4AAA-_ ECX20F8AAA-_ XTAR018C10A_ 115 2 — 120 ECX20F1AAC-_ ECX20F4AAC-_ ECX20F8AAC-_ XTAR018C10A_ 208 2 5 208 ECX20F1EAC-_ ECX20F4EAC-_ ECX20F8EAC-_ XTAR018C10E_ 230 3 5 240 ECX20F1BAC-_ ECX20F4BAC-_ ECX20F8BAC-_ XTAR018C10B_ 380 — 7-1/2 380/50 Hz ECX20F1LAC-_ ECX20F4LAC-_ ECX20F8LAC-_ XTAR018C10L_ 460 — 10 480 ECX20F1CAC-_ ECX20F4CAC-_ ECX20F8CAC-_ XTAR018C10C_ 575 — 15 600 ECX20F1DAC-_ ECX20F4DAC-_ ECX20F8DAC-_ XTAR018C10D_ Frame G 25 — — — — 30A ECX20G1AAA-_ ECX20G4AAA-_ ECX20G8AAA-_ XTAR025C10A_ 115 2 — 120 ECX20G1AAC-_ ECX20G4AAC-_ ECX20G8AAC-_ XTAR025C10A_ 208 3 7-1/2 208 ECX20G1EAC-_ ECX20G4EAC-_ ECX20G8EAC-_ XTAR025C10E_ 230 5 7-1/2 240 ECX20G1BAC-_ ECX20G4BAC-_ ECX20G8BAC-_ XTAR025C10B_ 380 — 10 380/50 Hz ECX20G1LAC-_ ECX20G4LAC-_ ECX20G8LAC-_ XTAR025C10L_ 460 — 15 480 ECX20G1CAC-_ ECX20G4CAC-_ ECX20G8CAC-_ XTAR025C10C_ 575 — 10 600 ECX20G1DAC-_ ECX20G4DAC-_ ECX20G8DAC-_ XTAR025C10D_ Frame H 32 — — — — 60A ECX20H1AAA-_ ECX20H4AAA-_ ECX20H8AAA-_ XTAR032C10A_ 115 3 — 120 ECX20H1AAE-_ ECX20H4AAE-_ ECX20H8AAE-_ XTAR032C10A_ 208 5 10 208 ECX20H1EAE-_ ECX20H4EAE-_ ECX20H8EAE-_ XTAR032C10E_ 230 5 10 240 ECX20H1BAE-_ ECX20H4BAE-_ ECX20H8BAE-_ XTAR032C10B_ 380 — 15 380/50 Hz ECX20H1LAE-_ ECX20H4LAE-_ ECX20H8LAE-_ XTAR032C10L_ 460 — 20 480 ECX20H1CAE-_ ECX20H4CAE-_ ECX20H8CAE-_ XTAR032C10C_ 575 — 25 600 ECX20H1DAE-_ ECX20H4DAE-_ ECX20H8DAE-_ XTAR032C10D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX20B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-187 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-208. Class ECX20 — Combination Reversing Starter — Fusible/Non-fusible Disconnect (Continued) � � Amps Maximum hp Coil Voltage Fuse Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Clips Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame J 40 — — — — 60A ECX20J1AAA-_ ECX20J4AAA-_ ECX20J8AAA-_ XTAR040D00A_ 115 3 — 120 ECX20J1AAE-_ ECX20J4AAE-_ ECX20J8AAE-_ XTAR040D00A_ 208 5 10 208 ECX20J1EAE-_ ECX20J4EAE-_ ECX20J8EAE-_ XTAR040D00E_ 34 230 7-1/2 15 240 ECX20J1BAE-_ ECX20J4BAE-_ ECX20J8BAE-_ XTAR040D00B_ 380 — 15 380/50 Hz ECX20J1LAE-_ ECX20J4LAE-_ ECX20J8LAE-_ XTAR040D00L_ 460 — 30 480 ECX20J1CAE-_ ECX20J4CAE-_ ECX20J8CAE-_ XTAR040D00C_ 575 — 40 600 ECX20J1DAE-_ ECX20J4DAE-_ ECX20J8DAE-_ XTAR040D00D_ Frame K 50 — — — — 100A ECX20K1AAA-_ ECX20K4AAA-_ ECX20K8AAA-_ XTAR050D00A_ 115 3 — 120 ECX20K1AAG-_ ECX20K4AAG-_ ECX20K8AAG-_ XTAR050D00A_ 208 7-1/2 15 208 ECX20K1EAG-_ ECX20K4EAG-_ ECX20K8EAG-_ XTAR050D00E_ 230 10 20 240 ECX20K1BAG-_ ECX20K4BAG-_ ECX20K8BAG-_ XTAR050D00B_ 380 — 20 380/50 Hz ECX20K1LAG-_ ECX20K4LAG-_ ECX20K8LAG-_ XTAR050D00L_ 460 — 40 480 ECX20K1CAG-_ ECX20K4CAG-_ ECX20K8CAG-_ XTAR050D00C_ 575 — 50 600 ECX20K1DAG-_ ECX20K4DAG-_ ECX20K8DAG-_ XTAR050D00D_ Frame L 65 — — — — 100A ECX20L1AAA-_ ECX20L4AAA-_ ECX20L8AAA-_ XTAR065D00A_ 115 5 — 120 ECX20L1AAG-_ ECX20L4AAG-_ ECX20L8AAG-_ XTAR065D00A_ 208 10 20 208 ECX20L1EAG-_ ECX20L4EAG-_ ECX20L8EAG-_ XTAR065D00E_ 230 15 25 240 ECX20L1BAG-_ ECX20L4BAG-_ ECX20L8BAG-_ XTAR065D00B_ 380 — 30 380/50 Hz ECX20L1LAG-_ ECX20L4LAG-_ ECX20L8LAG-_ XTAR065D00L_ 460 — 50 480 ECX20L1CAG-_ ECX20L4CAG-_ ECX20L8CAG-_ XTAR065D00C_ 575 — 60 600 ECX20L1DAG-_ ECX20L4DAG-_ ECX20L8DAG-_ XTAR065D00D_ Frame M 80— — — — 100A ECX20M1AAA-_ ECX20M4AAA-_ ECX20M8AAA-_ XTAR080F00A_ 115 7-1/2 — 120 ECX20M1AAG-_ ECX20M4AAG-_ ECX20M8AAG-_ XTAR080F00A_ 208 15 25 208 ECX20M1EAG-_ ECX20M4EAG-_ ECX20M8EAG-_ XTAR080F00E_ 230 15 30 240 ECX20M1BAG-_ ECX20M4BAG-_ ECX20M8BAG-_ XTAR080F00B_ 380 — 50 380/50 Hz ECX20M1LAG-_ ECX20M4LAG-_ ECX20M8LAG-_ XTAR080F00L_ 460 — 60 480 ECX20M1CAG-_ ECX20M4CAG-_ ECX20M8CAG-_ XTAR080F00C_ 575 — 75 600 ECX20M1DAG-_ ECX20M4DAG-_ ECX20M8DAG-_ XTAR080F00D_ � Frame N � 95 — — — — ECX20N1AAA-_ ECX20N4AAA-_ ECX20N8AAA-_ XTAR095F00A_ 115 7-1/2 — 120 ECX20N1AAH-_ ECX20N4AAH-_ ECX20N8AAH-_ XTAR095F00A_ 208 15 25 208 ECX20N1EAH-_ ECX20N4EAH-_ ECX20N8EAH-_ XTAR095F00E_ 230 15 40 240 ECX20N1BAH-_ ECX20N4BAH-_ ECX20N8BAH-_ XTAR095F00B_ 380 — 60 380/50 Hz ECX20N1LAH-_ ECX20N4LAH-_ ECX20N8LAH-_ XTAR095F00L_ 460 — 75 480 ECX20N1CAH-_ ECX20N4CAH-_ ECX20N8CAH-_ XTAR095F00C_ 575 — 100 600 ECX20N1DAH-_ ECX20N4DAH-_ ECX20N8DAH-_ XTAR095F00D_ � Frame P � 105 — — — — ECX20P1AAA-_ ECX20P4AAA-_ ECX20P8AAA-_ XTAR115G00A_ 115 10 — 120 ECX20P1AAH-_ ECX20P4AAH-_ ECX20P8AAH-_ XTAR115G00A_ 208 25 30 208 ECX20P1EAH-_ ECX20P4EAH-_ ECX20P8EAH-_ XTAR115G00E_ 230 25 40 240 ECX20P1BAH-_ ECX20P4BAH-_ ECX20P8BAH-_ XTAR115G00B_ 380 — 60 380/50 Hz ECX20P1LAH-_ ECX20P4LAH-_ ECX20P8LAH-_ XTAR115G00L_ 460 — 75 480 ECX20P1CAH-_ ECX20P4CAH-_ ECX20P8CAH-_ XTAR115G00C_ 575 — 100 600 ECX20P1DAH-_ ECX20P4DAH- ECX20P8DAH-_ XTAR115G00D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX20B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. � Non-fused Disconnect only. Cover Control . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-188 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-209. Class ECX25 — Combination Non-reversing Starter — Circuit Breaker � � Amps Maximum hp Coil Voltage HMCP Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame B 7 115 1/4 — 120 7A ECX25B1AAC-_ ECX25B4AAC-_ ECX25B8AAC-_ XTAE007B10A_ 208 3/4 1-1/2 208 ECX25B1EAC-_ ECX25B4EAC-_ ECX25B8EAC-_ XTAE007B10E_ 230 1 2 240 ECX25B1BAC-_ ECX25B4BAC-_ ECX25B8BAC-_ XTAE007B10B_ 34 380 — 3 380/50 Hz ECX25B1LAC-_ ECX25B4LAC-_ ECX25B8LAC-_ XTAE007B10L_ 460 — 3 480 ECX25B1CAC-_ ECX25B4CAC-_ ECX25B8CAC-_ XTAE007B10C_ 575 — 5 600 ECX25B1DAC-_ ECX25B4DAC-_ ECX25B8DAC-_ XTAE007B10D_ Frame C 9 115 1/2 — 120 15A ECX25C1AAD-_ ECX25C4AAD-_ ECX25C8AAD-_ XTAE009B10A_ 208 1 2 208 ECX25C1EAD-_ ECX25C4EAD-_ ECX25C8EAD-_ XTAE009B10E_ 230 1-1/2 3 240 ECX25C1BAD-_ ECX25C4BAD-_ ECX25C8BAD-_ XTAE009B10B_ 380 — 5 380/50 Hz ECX25C1LAD-_ ECX25C4LAD-_ ECX25C8LAD-_ XTAE009B10L_ 460 — 5 480 ECX25C1CAD-_ ECX25C4CAD-_ ECX25C8CAD-_ XTAE009B10C_ 575 — 7-1/2 600 ECX25C1DAD-_ ECX25C4DAD-_ ECX25C8DAD-_ XTAE009B10D_ Frame D 12 115 1/2 — 120 15A ECX25D1AAD-_ ECX25D4AAD-_ ECX25D8AAD-_ XTAE012B10A_ 208 1-1/2 3 208 ECX25D1EAD-_ ECX25D4EAD-_ ECX25D8EAD-_ XTAE012B10E_ 230 2 3 240 ECX25D1BAD-_ ECX25D4BAD-_ ECX25D8BAD-_ XTAE012B10B_ 380 — 5 380/50 Hz ECX25D1LAD-_ ECX25D4LAD-_ ECX25D8LAD-_ XTAE012B10L_ 460 — 7-1/2 480 ECX25D1CAD-_ ECX25D4CAD-_ ECX25D8CAD-_ XTAE012B10C_ 575 — 10 600 ECX25D1DAD-_ ECX25D4DAD-_ ECX25D8DAD-_ XTAE012B10D_ Frame E 15 115 3/4 — 120 30A ECX25E1AAE-_ ECX25E4AAE-_ ECX25E8AAE-_ XTAE015B10A_ 208 2 3 208 ECX25E1EAE-_ ECX25E4EAE-_ ECX25E8EAE-_ XTAE015B10E_ 230 2 3 240 ECX25E1BAE-_ ECX25E4BAE-_ ECX25E8BAE-_ XTAE015B10B_ 380 — 5 380/50 Hz ECX25E1LAE-_ ECX25E4LAE-_ ECX25E8LAE-_ XTAE015B10L_ 460 — 7-1/2 480 ECX25E1CAE-_ ECX25E4CAE-_ ECX25E8CAE-_ XTAE015B10C_ 575 — 10 600 ECX25E1DAE-_ ECX25E4DAE-_ ECX25E8DAE-_ XTAE015B10D_ Frame F 18 115 2 — 120 30A ECX25F1AAE-_ ECX25F4AAE-_ ECX25F8AAE-_ XTAE018C10A_ 208 2 5 208 ECX25F1EAE-_ ECX25F4EAE-_ ECX25F8EAE-_ XTAE018C10E_ 230 3 5 240 ECX25F1BAE-_ ECX25F4BAE-_ ECX25F8BAE-_ XTAE018C10B_ 380 — 7-1/2 380/50 Hz ECX25F1LAE-_ ECX25F4LAE-_ ECX25F8LAE-_ XTAE018C10L_ 460 — 10 480 ECX25F1CAE-_ ECX25F4CAE-_ ECX25F8CAE-_ XTAE018C10C_ 575 — 15 600 ECX25F1DAE-_ ECX25F4DAE-_ ECX25F8DAE-_ XTAE018C10D_ Frame G 25 115 2 — 120 50A ECX25G1AAF-_ ECX25G4AAF-_ ECX25G8AAF-_ XTAE025C10A_ 208 3 7-1/2 208 ECX25G1EAF-_ ECX25G4EAF-_ ECX25G8EAF-_ XTAE025C10E_ 230 5 7-1/2 240 ECX25G1BAF-_ ECX25G4BAF-_ ECX25G8BAF-_ XTAE025C10B_ 380 — 10 380/50 Hz ECX25G1LAF-_ ECX25G4LAF-_ ECX25G8LAF-_ XTAE025C10L_ 460 — 15 480 ECX25G1CAF-_ ECX25G4CAF-_ ECX25G8CAF-_ XTAE025C10C_ 575 — 10 600 ECX25G1DAF-_ ECX25G4DAF-_ ECX25G8DAF-_ XTAE025C10D_ Frame H 32 115 3 — 120 50A ECX25H1AAF-_ ECX25H4AAF-_ ECX25H8AAF-_ XTAE032C10A_ 208 5 10 208 ECX25H1EAF-_ ECX25H4EAF-_ ECX25H8EAF-_ XTAE032C10E_ 230 5 10 240 ECX25H1BAF-_ ECX25H4BAF-_ ECX25H8BAF-_ XTAE032C10B_ 380 — 15 380/50 Hz ECX25H1LAF-_ ECX25H4LAF-_ ECX25H8LAF-_ XTAE032C10L_ 460 — 20 480 ECX25H1CAF-_ ECX25H4CAF-_ ECX25H8CAF-_ XTAE032C10C_ 575 — 25 600 ECX25H1DAF-_ ECX25H4DAF-_ ECX25H8DAF-_ XTAE032C10D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX25B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-189 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-209. Class ECX25 — Combination Non-reversing Starter — Circuit Breaker (Continued) � � Amps Maximum hp Coil Voltage HMCP Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame J 40 115 3 — 120 50A ECX25J1AAF-_ ECX25J4AAF-_ ECX25J8AAF-_ XTAE040D00A_ 208 5 10 208 ECX25J1EAF-_ ECX25J4EAF-_ ECX25J8EAF-_ XTAE040D00E_ 230 7-1/2 15 240 ECX25J1BAF-_ ECX25J4BAF-_ ECX25J8BAF-_ XTAE040D00B_ 380 — 15 380/50 Hz ECX25J1LAF-_ ECX25J4LAF-_ ECX25J8LAF-_ XTAE040D00L_ 34 460 — 30 480 ECX25J1CAF-_ ECX25J4CAF-_ ECX25J8CAF-_ XTAE040D00C_ 575 — 40 600 ECX25J1DAF-_ ECX25J4DAF-_ ECX25J8DAF-_ XTAE040D00D_ Frame K 50 115 3 — 120 70A ECX25K1AAW-_ ECX25K4AAW-_ ECX25K8AAW-_ XTAE050D00A_ 208 7-1/2 15 208 ECX25K1EAW-_ ECX25K4EAW-_ ECX25K8EAW-_ XTAE050D00E_ 230 10 20 240 ECX25K1BAW-_ ECX25K4BAW-_ ECX25K8BAW-_ XTAE050D00B_ 380 — 20 380/50 Hz ECX25K1LAW-_ ECX25K4LAW-_ ECX25K8LAW-_ XTAE050D00L_ 460 — 40 480 ECX25K1CAW-_ ECX25K4CAW-_ ECX25K8CAW-_ XTAE050D00C_ 575 — 50 600 ECX25K1DAW-_ ECX25K4DAW-_ ECX25K8DAW-_ XTAE050D00D_ Frame L 65 115 5 — 120 70A ECX25L1AAW-_ ECX25L4AAW-_ ECX25L8AAW-_ XTAE065D00A_ 208 10 20 208 ECX25L1EAW-_ ECX25L4EAW-_ ECX25L8EAW-_ XTAE065D00E_ 230 15 25 240 ECX25L1BAW-_ ECX25L4BAW-_ ECX25L8BAW-_ XTAE065D00B_ 380 — 30 380/50 Hz ECX25L1LAW-_ ECX25L4LAW-_ ECX25L8LAW-_ XTAE065D00L_ 460 — 50 480 ECX25L1CAW-_ ECX25L4CAW-_ ECX25L8CAW-_ XTAE065D00C_ 575 — 60 600 ECX25L1DAW-_ ECX25L4DAW-_ ECX25L8DAW-_ XTAE065D00D_ Frame M 80 115 7-1/2 — 120 100A ECX25M1AAG-_ ECX25M4AAG-_ ECX25M8AAG-_ XTAE080F00A_ 208 15 25 208 ECX25M1EAG-_ ECX25M4EAG-_ ECX25M8EAG-_ XTAE080F00E_ 230 15 30 240 ECX25M1BAG-_ ECX25M4BAG-_ ECX25M8BAG-_ XTAE080F00B_ 380 — 50 380/50 Hz ECX25M1LAG-_ ECX25M4LAG-_ ECX25M8LAG-_ XTAE080F00L_ 460 — 60 480 ECX25M1CAG-_ ECX25M4CAG-_ ECX25M8CAG-_ XTAE080F00C_ 575 — 75 600 ECX25M1DAG-_ ECX25M4DAG-_ ECX25M8DAG-_ XTAE080F00D_ Frame N 95 115 7-1/2 — 120 100A ECX25N1AAG-_ ECX25N4AAG-_ ECX25N8AAG-_ XTAE095F00A_ 208 15 25 208 ECX25N1EAG-_ ECX25N4EAG-_ ECX25N8EAG-_ XTAE095F00E_ 230 15 40 240 ECX25N1BAG-_ ECX25N4BAG-_ ECX25N8BAG-_ XTAE095F00B_ 380 — 60 380/50 Hz ECX25N1LAG-_ ECX25N4LAG-_ ECX25N8LAG-_ XTAE095F00L_ 460 — 75 480 ECX25N1CAG-_ ECX25N4CAG-_ ECX25N8CAG-_ XTAE095F00C_ 575 — 100 600 ECX25N1DAG-_ ECX25N4DAG-_ ECX25N8DAG-_ XTAE095F00D_ Frame P 115 115 10 — 120 150A ECX25P1AAH-_ ECX25P4AAH-_ ECX25P8AAH-_ XTAE115G00A_ 208 25 40 208 ECX25P1EAH-_ ECX25P4EAH-_ ECX25P8EAH-_ XTAE115G00E_ 230 25 50 240 ECX25P1BAH-_ ECX25P4BAH-_ ECX25P8BAH-_ XTAE115G00B_ 380 — 60 380/50 Hz ECX25P1LAH-_ ECX25P4LAH-_ ECX25P8LAH-_ XTAE115G00L_ 460 — 100 480 ECX25P1CAH-_ ECX25P4CAH-_ ECX25P8CAH-_ XTAE115G00C_ 575 — 125 600 ECX25P1DAH-_ ECX25P4DAH-_ ECX25P8DAH-_ XTAE115G00D_ Frame Q 125 115 15 — 120 150A ECX25Q1AAH-_ ECX25Q4AAH-_ ECX25Q8AAH-_ XTAE150G00A_ 208 25 40 208 ECX25Q1EAH-_ ECX25Q4EAH-_ ECX25Q8EAH-_ XTAE150G00E_ 230 25 50 240 ECX25Q1BAH-_ ECX25Q4BAH-_ ECX25Q8BAH-_ XTAE150G00B_ 380 — 75 380/50 Hz ECX25Q1LAH-_ ECX25Q4LAH-_ ECX25Q8LAH-_ XTAE150G00L_ 460 — 100 480 ECX25Q1CAH-_ ECX25Q4CAH-_ ECX25Q8CAH-_ XTAE150G00C_ 575 — 125 600 ECX25Q1DAH-_ ECX25Q4DAH-_ ECX25Q8DAH-_ XTAE150G00D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX25B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-190 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-210. Class ECX26 — Combination Reversing Starter — Circuit Breaker � � Amps Maximum hp Coil Voltage HMCP Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame B 7 115 1/4 — 120 7A ECX26B1AAC-_ ECX26B4AAC-_ ECX26B8AAC-_ XTAR007B10A_ 208 3/4 1-1/2 208 ECX26B1EAC-_ ECX26B4EAC-_ ECX26B8EAC-_ XTAR007B10E_ 230 1 2 240 ECX26B1BAC-_ ECX26B4BAC-_ ECX26B8BAC-_ XTAR007B10B_ 34 380 — 3 380/50 Hz ECX26B1LAC-_ ECX26B4LAC-_ ECX26B8LAC-_ XTAR007B10L_ 460 — 3 480 ECX26B1CAC-_ ECX26B4CAC-_ ECX26B8CAC-_ XTAR007B10C_ 575 — 5 600 ECX26B1DAC-_ ECX26B4DAC-_ ECX26B8DAC-_ XTAR007B10D_ Frame C 9 115 1/2 — 120 15A ECX26C1AAD-_ ECX26C4AAD-_ ECX26C8AAD-_ XTAR009B10A_ 208 1 2 208 ECX26C1EAD-_ ECX26C4EAD-_ ECX26C8EAD-_ XTAR009B10E_ 230 1-1/2 3 240 ECX26C1BAD-_ ECX26C4BAD-_ ECX26C8BAD-_ XTAR009B10B_ 380 — 5 380/50 Hz ECX26C1LAD-_ ECX26C4LAD-_ ECX26C8LAD-_ XTAR009B10L_ 460 — 5 480 ECX26C1CAD-_ ECX26C4CAD-_ ECX26C8CAD-_ XTAR009B10C_ 575 — 7-1/2 600 ECX26C1DAD-_ ECX26C4DAD-_ ECX26C8DAD-_ XTAR009B10D_ Frame D 12 115 1/2 — 120 15A ECX26D1AAD-_ ECX26D4AAD-_ ECX26D8AAD-_ XTAR012B10A_ 208 1-1/2 3 208 ECX26D1EAD-_ ECX26D4EAD-_ ECX26D8EAD-_ XTAR012B10E_ 230 2 3 240 ECX26D1BAD-_ ECX26D4BAD-_ ECX26D8BAD-_ XTAR012B10B_ 380 — 5 380/50 Hz ECX26D1LAD-_ ECX26D4LAD-_ ECX26D8LAD-_ XTAR012B10L_ 460 — 7-1/2 480 ECX26D1CAD-_ ECX26D4CAD-_ ECX26D8CAD-_ XTAR012B10C_ 575 — 10 600 ECX26D1DAD-_ ECX26D4DAD-_ ECX26D8DAD-_ XTAR012B10D_ Frame E 15 115 3/4 — 120 30A ECX26E1AAE-_ ECX26E4AAE-_ ECX26E8AAE-_ XTAR015B10A_ 208 2 3 208 ECX26E1EAE-_ ECX26E4EAE-_ ECX26E8EAE-_ XTAR015B10E_ 230 2 3 240 ECX26E1BAE-_ ECX26E4BAE-_ ECX26E8BAE-_ XTAR015B10B_ 380 — 5 380/50 Hz ECX26E1LAE-_ ECX26E4LAE-_ ECX26E8LAE-_ XTAR015B10L_ 460 — 7-1/2 480 ECX26E1CAE-_ ECX26E4CAE-_ ECX26E8CAE-_ XTAR015B10C_ 575 — 10 600 ECX26E1DAE-_ ECX26E4DAE-_ ECX26E8DAE-_ XTAR015B10D_ Frame F 18 115 2 — 120 30A ECX26F1AAE-_ ECX26F4AAE-_ ECX26F8AAE-_ XTAR018C10A_ 208 2 5 208 ECX26F1EAE-_ ECX26F4EAE-_ ECX26F8EAE-_ XTAR018C10E_ 230 3 5 240 ECX26F1BAE-_ ECX26F4BAE-_ ECX26F8BAE-_ XTAR018C10B_ 380 — 7-1/2 380/50 Hz ECX26F1LAE-_ ECX26F4LAE-_ ECX26F8LAE-_ XTAR018C10L_ 460 — 10 480 ECX26F1CAE-_ ECX26F4CAE-_ ECX26F8CAE-_ XTAR018C10C_ 575 — 15 600 ECX26F1DAE-_ ECX26F4DAE-_ ECX26F8DAE-_ XTAR018C10D_ Frame G 25 115 2 — 120 50A ECX26G1AAF-_ ECX26G4AAF-_ ECX26G8AAF-_ XTAR025C10A_ 208 3 7-1/2 208 ECX26G1EAF-_ ECX26G4EAF-_ ECX26G8EAF-_ XTAR025C10E_ 230 5 7-1/2 240 ECX26G1BAF-_ ECX26G4BAF-_ ECX26G8BAF-_ XTAR025C10B_ 380 — 10 380/50 Hz ECX26G1LAF-_ ECX26G4LAF-_ ECX26G8LAF-_ XTAR025C10L_ 460 — 15 480 ECX26G1CAF-_ ECX26G4CAF-_ ECX26G8CAF-_ XTAR025C10C_ 575 — 10 600 ECX26G1DAF-_ ECX26G4DAF-_ ECX26G8DAF-_ XTAR025C10D_ Frame H 32 115 3 — 120 50A ECX26H1AAF-_ ECX26H4AAF-_ ECX26H8AAF-_ XTAR032C10A_ 208 5 10 208 ECX26H1EAF-_ ECX26H4EAF-_ ECX26H8EAF-_ XTAR032C10E_ 230 5 10 240 ECX26H1BAF-_ ECX26H4BAF-_ ECX26H8BAF-_ XTAR032C10B_ 380 — 15 380/50 Hz ECX26H1LAF-_ ECX26H4LAF-_ ECX26H8LAF-_ XTAR032C10L_ 460 — 20 480 ECX26H1CAF-_ ECX26H4CAF-_ ECX26H8CAF-_ XTAR032C10C_ 575 — 25 600 ECX26H1DAF-_ ECX26H4DAF-_ ECX26H8DAF-_ XTAR032C10D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX26B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-191 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-210. Class ECX26 — Combination Reversing Starter — Circuit Breaker (Continued) � � Amps Maximum hp Coil Voltage HMCP Type 1/IP23 Type 4X/IP66 Type 12/IP65 Component � @ 60 Hz Motor 1-Phase 3-Phase Catalog Price Catalog Price Catalog Price Catalog � � � � � Voltage Number U.S. $ Number U.S. $ Number U.S. $ Number Frame J 40 115 3 — 120 50A ECX26J1AAF-_ ECX26J4AAF-_ ECX26J8AAF-_ XTAR040D00A_ 208 5 10 208 ECX26J1EAF-_ ECX26J4EAF-_ ECX26J8EAF-_ XTAR040D00E_ 230 7-1/2 15 240 ECX26J1BAF-_ ECX26J4BAF-_ ECX26J8BAF-_ XTAR040D00B_ 34 380 — 15 380/50 Hz ECX26J1LAF-_ ECX26J4LAF-_ ECX26J8LAF-_ XTAR040D00L_ 460 — 30 480 ECX26J1CAF-_ ECX26J4CAF-_ ECX26J8CAF-_ XTAR040D00C_ 575 — 40 600 ECX26J1DAF-_ ECX26J4DAF-_ ECX26J8DAF-_ XTAR040D00D_ Frame K 50 115 3 — 120 70A ECX26K1AAW-_ ECX26K4AAW-_ ECX26K8AAW-_ XTAR050D00A_ 208 7-1/2 15 208 ECX26K1EAW-_ ECX26K4EAW-_ ECX26K8EAW-_ XTAR050D00E_ 230 10 20 240 ECX26K1BAW-_ ECX26K4BAW-_ ECX26K8BAW-_ XTAR050D00B_ 380 — 20 380/50 Hz ECX26K1LAW-_ ECX26K4LAW-_ ECX26K8LAW-_ XTAR050D00L_ 460 — 40 480 ECX26K1CAW-_ ECX26K4CAW-_ ECX26K8CAW-_ XTAR050D00C_ 575 — 50 600 ECX26K1DAW-_ ECX26K4DAW-_ ECX26K8DAW-_ XTAR050D00D_ Frame L 65 115 5 — 120 100A ECX26L1AAW-_ ECX26L4AAW-_ ECX26L8AAW-_ XTAR065D00A_ 208 10 20 208 ECX26L1EAW-_ ECX26L4EAW-_ ECX26L8EAW-_ XTAR065D00E_ 230 15 25 240 ECX26L1BAW-_ ECX26L4BAW-_ ECX26L8BAW-_ XTAR065D00B_ 380 — 30 380/50 Hz ECX26L1LAW-_ ECX26L4LAW-_ ECX26L8LAW-_ XTAR065D00L_ 460 — 50 480 ECX26L1CAW-_ ECX26L4CAW-_ ECX26L8CAW-_ XTAR065D00C_ 575 — 60 600 ECX26L1DAW-_ ECX26L4DAW-_ ECX26L8DAW-_ XTAR065D00D_ Frame M 80 115 7-1/2 — 120 100A ECX26M1AAG-_ ECX26M4AAG-_ ECX26M8AAG-_ XTAR080F00A_ 208 15 25 208 ECX26M1EAG-_ ECX26M4EAG-_ ECX26M8EAG-_ XTAR080F00E_ 230 15 30 240 ECX26M1BAG-_ ECX26M4BAG-_ ECX26M8BAG-_ XTAR080F00B_ 380 — 50 380/50 Hz ECX26M1LAG-_ ECX26M4LAG-_ ECX26M8LAG-_ XTAR080F00L_ 460 — 60 480 ECX26M1CAG-_ ECX26M4CAG-_ ECX26M8CAG-_ XTAR080F00C_ 575 — 75 600 ECX26M1DAG-_ ECX26M4DAG-_ ECX26M8DAG-_ XTAR080F00D_ Frame N 95 115 7-1/2 — 120 100A ECX26N1AAG-_ ECX26N4AAG-_ ECX26N8AAG-_ XTAR095F00A_ 208 15 25 208 ECX26N1EAG-_ ECX26N4EAG-_ ECX26N8EAG-_ XTAR095F00E_ 230 15 40 240 ECX26N1BAG-_ ECX26N4BAG-_ ECX26N8BAG-_ XTAR095F00B_ 380 — 60 380/50 Hz ECX26N1LAG-_ ECX26N4LAG-_ ECX26N8LAG-_ XTAR095F00L_ 460 — 75 480 ECX26N1CAG-_ ECX26N4CAG-_ ECX26N8CAG-_ XTAR095F00C_ 575 — 100 600 ECX26N1DAG-_ ECX26N4DAG-_ ECX26N8DAG-_ XTAR095F00D_ Frame P 115 115 10 — 120 150A ECX26P1AAH-_ ECX26P4AAH-_ ECX26P8AAH-_ XTAR115G00A_ 208 25 40 208 ECX26P1EAH-_ ECX26P4EAH-_ ECX26P8EAH-_ XTAR115G00E_ 230 25 50 240 ECX26P1BAH-_ ECX26P4BAH-_ ECX26P8BAH-_ XTAR115G00B_ 380 — 60 380/50 Hz ECX26P1LAH-_ ECX26P4LAH-_ ECX26P8LAH-_ XTAR115G00L_ 460 — 100 480 ECX26P1CAH-_ ECX26P4CAH-_ ECX26P8CAH-_ XTAR115G00C_ 575 — 125 600 ECX26P1DAH-_ ECX26P4DAH-_ ECX26P8DAH-_ XTAR115G00D_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 34-200. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX26B4AAA-_. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see PG03300001E. � Contact factory for other voltage options. Cover Control . . . . . . . . . . . . . . . . . . . Page 34-176 Wiring Diagrams . . . . . . . . . . . . . . . . Page 34-192 Dimensions . . . . . . . . . . . . . . . . . . . . . PG03300001E Accessories . . . . . . . . . . . . . . . . . . . . PG03300001E Modification Codes . . . . . . . . . . . . . . PG03300001E Technical Data . . . . . . . . . . . . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-192 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Wiring Diagrams FVNR with Pushbutton Control With 3-Position Selector Switch Hand A1 A2 M M OL T1 M 1 OFF 01 L1 2/3 3/4 T2 34 02 L2 Motor T3 Auto 03 L3 Remote Auto Contact Motor Run Control Power Transformer Option Stop Start OL M OL 95 96 A1 A2 1 M 01 L1 M 02 L2 2/3 3/4 Motor Stopped 03 L3 M 61 62/7 Overload Tripped OL 98 97 96 1 Reversing Combination Starter Wiring R 3-Position Switch F OL T1 Fwd 3 01 L1 T2 02 L2 Motor 1 OFF T3 03 L3 5 Rev OL 96 95 Fwd 2- and 3-Position Switch For F Stop Rev FLS R A1 A2 Fwd 3 1 Hand 3 1B 2 6 F (If Used) 1 OFF 5 1B Rev R RLS F Auto A1 A2 5 4 7 Remote R Rev Figure 34-145. Typical Wiring Diagram For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-193 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Remote Pilot Devices Connections for Non-reversing Starter 2-Wire Control Figure 1 Front View of Panel 3/14 AC Lines 1 3 5 1 “C” Not for Use with Auto L2 L3 L1 Reset OL Relays 34 3-Wire Control 1 A1 A2 Start 2/13 M 3/14 2/13 3/14 Stop 1 98 When More Than One Pushbutton Station is 97 Used, Omit Connector OL “A” and Connect per 96 Sketch Below Reset 2/ 4/ 6/ Start Start 95 T1 T2 T3 3/14 2/13 Stop Stop T2 Conversion to T1 T3 T2 1 4 1-Phase — Add 2 6 4 Dotted Line “A” Connections. T1 T2 T3 T1 T2 Separate Control Remove Wire “C” if Supplied and Connect Separate Control Lines to the Number 1 Terminal on the Remote Pilot Device 1-Phase and to the Number 96 Terminal 3-Phase on the Overload Relay. Motor Motor Local Control Options (If Used) Full Voltage Non-reversing Starters Figure A START/STOP Figure D 2-Positon Figure G Overload Pushbuttons Selector Switch Yellow Tripped Yellow 2/13 Start Black/White Hand Black X1 3/14 34 X2 Black Stop Red Red Black/White 1 1 Auto 3 12 2 4 Red 1 Figure B START/STOP Selector Switch 1 98 97 OL Black 3 96 3 1 Start Reset Red 95 1 4 2 Wire “C” Figure E Pilot Light 3-Position Figure C (Motor RUN) Selector Switch Connect to Coil Terminals “A1” & “A2” Yellow Figure F Pilot Light To Coil Hand (Motor Stop) Connect to Black/White X1 Remote NC Interlock Switch Black/White X1 X2 Black Connect to OL 3 Auto 3 To Coil Black/White X2 Terminal No. 96 Black/White 4 4 Red 1 Figure 34-146. Typical Wiring Diagram — Non-combination Starters (Non-reversing) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-194 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Wire “F” – Used Figure 1 Reversing Starter Elementary Diagram Remote Control with Local Front View of Panel Stations Control Pushbuttons AC 32 Lines Contactors “F” and “R” are 5 SPDT Hold Down 4 Lines L1 L2 L3 Mechanically Interlocked Switch Pushbutton 1 3 5 L1 L2 L3 For For C320KGT5 F OL 3 Auxiliary 61 61 3 53 53 Contact 1 34 1 R Rev 54 54 62 62 5 5 T1 Rev F OL T2 R T3 AC 1 Pushbutton Motor OL F For A1 A2 A2 A1 R F R 3 “C” 2 Rev 4 For. Rev. Stop F OL R A2 A1 5 98 3 2 62 1 95 96 Stop 61 F “C” 1 97 53 54 OL 96 R F A1 A2 Reset 6 2 4 4 5 62 61 T3 R T1 T2 95 Pushbutton with FOR T1 T2 T3 and REV Buttons 53 54 2 4 6 Electrically Interlocked For T1 T2 T3 Separate Control 2 3 Remove Wire “C” if Supplied Rev and Connect Separate Control Lines to the Number 1 Terminal on the Remote Pilot Device and 4 AC to the Number 96 Terminal on 5 Motor Stop the Overload Relay. 1 Figure 34-147. Typical Wiring Diagram — Non-combination Starters (Reversing) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-195 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-215. Class 19 — FVNR Combination with Disconnect Switch Dimensions and Fuseblock IEC Size Box Ship Weight Enclosure Boxes (Frame / Amps) Number in kg [Lb] Type 1, 3R, 4, 4X, 12 XT B – J / 7 – 40A 7A 13.6 [30] B – J / 7 – 40A 7P 11.8 [26] Non-combination Starters K – M / 65 – 85A 8 25 [55] Table 34-211. Class 09 — FVNR Starters K – M / 65 – 85A 8P 23.2 [51] 34 (Non-combination) Table 34-216. Class 20 — FVR Combination with Disconnect Switch IEC Size Box Ship Weight (Frame / Amps) Number in kg [Lb] IEC Size Box Ship Weight (Frame / Amps) Number in kg [Lb] B – H / 7 – 25A 1 3.2 [7] B – H / 7 – 32A 5A 6.4 [14] B – J / 7 – 40A 7A 9.1 [20] B – H / 7 – 32A 5P 4.5 [10] B – J / 7 – 40A 7P 7.3 [16] J – L / 40 – 65A 5A 18.6 [41] K – N / 50 – 105A 8 26.3 [58] J – L / 40 – 65A 5P 17.7 [39] K – N / 50 – 105A 8P 25 [55] M – Q / 80 – 150A 8 15.9 [35] Table 34-217. Class 20 — FVR Combination with Disconnect Switch and Fuseblock Table 34-212. Class 10 — FVR Starters (Non-combination) IEC Size Box Ship Weight (Frame / Amps) Number in kg [Lb] IEC Size Box Ship Weight (Frame / Amps) Number in kg [Lb] B – J / 7 – 40A 7A 14.1 [31] B – J / 7 – 40A 7P 12.3 [27] B – H / 7 – 32A 2 5.9 [13] K – M / 65 – 85A 8 25.4 [56] B – H / 7 – 32A 5A 6.8 [15] K – M / 65 – 85A 8P 23.6 [52] B – H / 7 – 32A 5P 5.0 [11] J – L / 40 – 65A 2 18.2 [40] J – L / 40 – 65A 6A 24.5 [45] Type 1, 3R, 4, 4X, 12 XT HMCP J – L / 40 – 65A 6P 19.1 [42] Combination Starters M – Q / 80 – 125A 4 22.7 [50] Table 34-218. Class 25 — FVNR Combination with HMCP M – Q / 80 – 150A 8 18.6 [41] IEC Size Box Ship Weight Table 34-213. Class 11 — FVNR Starters (Frame / Amps) Number in kg [Lb] (Non-combination with CPT) B – H / 7 – 32A 7A 10 [23] IEC Size Box Ship Weight B – H / 7 – 32A 7P 8.2 [18] (Frame / Amps) Number in kg [Lb] J – L / 40 – 65A 7A 11 [24] J – L / 40 – 65A 7P 8.9 [20] B – H / 7 – 32A 2 6.4 [14] B – H / 7 – 32A 5A 8.4 [19] M – Q / 80 – 125A 8 31.8 [70] B – H / 7 – 32A 5P 6.6 [15] Table 34-219. Class 26 — FVR Combination with HMCP J – L / 40 – 65A 2 19.5 [43] J – L / 40 – 65A 6A 23.2 [51] IEC Size Box Ship Weight J – L / 40 – 65A 6P 21.8 [48] (Frame / Amps) Number in kg [Lb] M – Q / 80 – 125A 4 23.6 [52] B – H / 7 – 32A 7A 12 [26] M – Q / 80 – 150A 8 24.1 [53] B – H / 7 – 32A 7P 10 [22] J – L / 40 – 65A 7A 13 [29] Type 1, 3R, 4, 4X, 12 XT Fusible/Non-fusible Starters J – L / 40 – 65A 7P 11 [25] Table 34-214. Class 19 — FVNR Combination with Disconnect Switch M – P / 80 – 115A 8 31.8 [70] IEC Size Box Ship Weight (Frame / Amps) Number in kg [Lb] Box Dimensions B – J / 7 – 40A 7A 8.6 [19] For Box Dimensions, see Enclosed Control Product Guide, B – J / 7 – 40A 7P 6.8 [15] PG03300001E. K – N / 50 – 105A 8 24.1 [53] K – N / 50 – 105A 8P 22.2 [49] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-196 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Modification Codes Table 34-220. A — Ammeters, Auxiliary Contacts, Accelerating Relays, Table 34-220. A — Ammeters, Auxiliary Contacts, Accelerating Relays, Autotransformers Autotransformers (Continued) Modification Catalog Description Adder Modification Catalog Description Adder Number U.S. $ Number U.S. $ Suffix Suffix Ammeter A1 Panel Type Wired to Current Side Mounted A35 3NC 34 Transformer in Line 1, Type 1, 12 Auxiliary A36 3NO-1NC Contacts, Panel Type Wired to Current � A37 2NO-2NC continued Transformer in Line 1, Type 3R, 4X A38 1NO-3NC A2 Panel Type, Selector Switch and A39 4NO 3 Current Transformers Wired to Ammeter via Switch, Type 1, 12 A40 4NC Panel Type, Selector Switch and Auxiliary A42 Contacts Mounted on Operating 3 Current Transformers Wired to Contacts Mechanism of Disconnect Switch, Ammeter via Switch, Type 3R, 4X 1NO-1NC A3 Miniature (Single-Phase), Type 1, 12 A43 Contacts Mounted on Operating Mechanism of Disconnect Switch, A4 Miniature with Selector Switch, 2NO-2NC Type 1, 12 A44 With Auxiliary Contact Omitted A5 Switchboard (Single-Phase), Type 1, 12 Accelerating A46 For 2-Speed Switchboard (Single-Phase), Type 3R, Relay 4X � Available on XT Starters for 40A and greater only. A6 Switchboard with Selector Switch, Type 1, 12 Table 34-221. B — Breaker Modifications, Backspin Timer, Switchboard with Selector Switch, Undervoltage Release, Bell Alarm, Bus Choke Type 3R, 4X Modification Catalog Description Adder A7 3-Panel Type (Single-Phase), Type 1, 12 Number U.S. $ 3-Panel Type (Single-Phase), Suffix Type 3R, 4X Breaker B1 1NO-1NC Auxiliary Contact on Breaker A10 3 Miniature (Single-Phase), Type 1, 3R, 4X, 12 B2 2NO-2NC Auxiliary Contacts on Breaker A11 3 Switchboard Type (Single-Phase), B3 Shunt Trip on Circuit Breaker — Type 1, 12 48 – 127V AC or DC 3 Switchboard Type (Single-Phase), B4 Shunt Trip on Circuit Breaker — Type 3R, 4X 9 – 24V AC or DC A12 Ammeter Order by Description, Type 1, B5 Shunt Trip on Circuit Breaker — 3R, 4X, 12 208 – 380V AC Top Mounted A13 1NO B6 Shunt Trip on Circuit Breaker — Auxiliary 415 – 600V AC or 220 – 250V DC A14 1NC � Contacts B8 Undervoltage Release for Breaker A15 1NO-1NC (Unwired) B9 Current Limiter Mounted to Breaker A16 2NO B10 Breaker — Order by Description A17 2NC B11 Thermal Magnetic Breaker A18 2NO-1NC Backspin B12 180 Seconds A19 1NO-2NC Timer A20 3NO Undervoltage B13 Undervoltage Release for Circuit IEC Sizes A21 3NC Release Breaker — 208 – 240V AC B – L Only A22 3NO-1NC B14 Undervoltage Release for Circuit (Unwired) Breaker — 380 – 480V AC A23 2NO-2NC XT Series B15 Undervoltage Release for Circuit A24 1NO-3NC Breaker — 525 – 600V AC A25 4NO Bell Alarm B16 Bell Alarm for Circuit Breaker A26 4NC Side Mounted A27 1NO Auxiliary A28 1NC � Contacts A29 1NO-1NC A30 2NO A31 2NC A32 2NO-1NC A33 1NO-2NC A34 3NO � Top mounted auxiliary contacts cannot be added to contactors in Box 1 (Type 1). � Available on XT Starters for 40A and greater only. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-197 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-222. C — Control Power Transformer, IT. Power Supplies, Table 34-222. C — Control Power Transformer, IT. Power Supplies, Control Relays, Cover Control (not elsewhere defined), Current Control Relays, Cover Control (not elsewhere defined), Current Transformers, Compelling Relay, Control Wiring, Control Circuit Breaker, Transformers, Compelling Relay, Control Wiring, Control Circuit Breaker, Separate Control, Customer-Supplied Components, Custom for Separate Control, Customer-Supplied Components, Custom for Advantage, Contactors, Counter, E-Stop Relay, DC/AC Interface, Advantage, Contactors, Counter, E-Stop Relay, DC/AC Interface, Separate Source Disconnect, Bypass Contactors Separate Source Disconnect, Bypass Contactors (Continued) Modification Catalog Description Adder Modification Catalog Description Adder Number U.S. $ Number U.S. $ Suffix Suffix 34 Control Power C1 Standard Size Control Transformer, Current C21 In Phase 1 Transformers 120V/60 Hz, 110V/50 Hz Secondary with Transformer(s) C22 In Phases 1 and 2 2 Primary and 1 Secondary Fuse C23 In 3 Phases Make sure C2 Standard Size Control Transformer, 8th character Control C26 Omit Control Wiring 24V/60 Hz Secondary with 2 Primary specifies Wiring and 1 Secondary Fuse C30 With Separate Control Wiring and primary/ Two 250V Fuses in Holder C42 50 VA Extra Capacity CPT 120V/60 Hz, secondary 110V/50 Hz with 2 Primary and C31 With Common Control Wiring and voltage. 1 Secondary Two600V (Class C) Fuses in Holder C3 100 VA Extra Capacity CPT, 120V/60 Hz, C33 Control Wiring Type — Order by 110V/50 Hz Secondary with Description 2 Primary and 1 Secondary Fuse Control C32 Order by Description C4 100 VA Extra Capacity CPT, 24V/60 Hz Circuit Secondary with 2 Primary and Breaker 1 Secondary Fuse Separate C35 Wired for Separate Control C5 200 VA Extra Capacity CPT, 120V/60 Hz, Control (Reduced Voltage) 110V/50 Hz Secondary with 2 Primary Customer C36 Customer Supplied Components and 1 Secondary Fuse Supplied to Be Installed C6 200 VA Extra Capacity CPT, 24V/60 Hz Components C37 Customer Supplied Wiring Diagram Secondary with 2 Primary and to Use 1 Secondary Fuse Contactor/ C40 Contactor/Starter — Order by C7 300 VA Extra Capacity CPT, 120V/60 Hz, Starter Description 110V/50 Hz Secondary with 2 Primary Counter C41 Operations Counter and 1 Secondary Fuse E-Stop Relay C43 E-Stop Relay (DeviceNet) C8 400 VA Extra Capacity CPT, 120V/60 Hz, 110V/50 Hz Secondary with 2 Primary Separate C45 IEC Separate Source Disconnect for and 1 Secondary Fuse Source Control Circuitry Disconnect C9 1 kVA Extra Capacity CPT, 120V/60 Hz, 110V/50 Hz Secondary with 2 Primary and 1 Secondary Fuse Table 34-223. D — Device Labels C10 2 kVA Extra Capacity CPT, 120V/60 Hz, Modification Catalog Description Adder 110V/50 Hz Secondary with 2 Primary Number U.S. $ and 1 Secondary Fuse Suffix C11 Control Transformer — Order by Device Labels D1 (Each Label) Description D12 Alternator Omitted (Deduct Price) C34 CPT with Power Supply for XT Power Supplies C27 Separate Control 120V AC to 24V DC C28 Power Supply with Extra Capacity — Order by Description Control Relays C12 4-Pole Interposing Relay, 600V (2NO/ 2NC) C13 Run Relay, 24V DC (MVX) C14 4-Pole, Unwired, A600 Rtg. — 2NO-2NC C15 8-Pole, Unwired, A600 Rtg. — 4NO-4NC C16 Control Relay — Order by Description Cover Control C17 Convert Position 7 to E30 Type Cover Control C19 Lock-Off Attachment Added on Cover Control C29 Change to E22 (22 mm) Cover Controls Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-198 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-224. E — Enclosure Modifications, Elapsed Time Meter, Table 34-228. N — Nameplates Duplex Outlet, Enclosure for Starter, Enclosure Clear Cover, Modification Catalog Description Adder Enclosure Material Number U.S. $ Suffix Modification Catalog Description Adder Number U.S. $ Nameplates N1 Enclosure Nameplates Suffix Enclosure E3 Oversize Enclosure Table 34-229. P — Pilot Lights, Pushbuttons, Phase Relays, Potential Modifications Transformers, Power Factor Correction Capacitors, Program Timer, E4 Enclosure — Order by Description 34 Percentage Timer, Photocell E8 Service Entrance Rating w/Ground Bar Modification Catalog Description Adder E11 Safety Door Interlock Number U.S. $ Elapsed Time E9 Wired Across Coil, Type 1, 12 Suffix Meter Wired Across Coil, Type 3R, 4X Push-to-Test P1 Push-to-Test Pilot Light (Red RUN) E10 Elapsed Time Meter — Order by Pilot Lights Wired to Coil Description P2 Push-to-Test Pilot Light (Green OFF) Duplex Outlet E12 Convenience Duplex Outlet Mounted in Wired in Series with Auxiliary Contact Side of Enclosure P3 Combination of P1 and P2 Above Enclosure E19 Clear Cover for Halyester Enclosure P4 Push-to-Test Pilot Light (Amber RUN) Clear Cover Nonmetallic Wired to Coil for XT P49 Push-to-Test Pilot Light (Green RUN) Enclosure E20 Convert to 316 Stainless Steel Material P57 Push-to-Test Pilot Light — Green STOP E21 Convert from Type 3R to Stainless Steel Pushbuttons P5 EMERGENCY STOP — Mushroom Head Table 34-225. F — Fuse Clips, Fuse Blocks, Fungus Protection, Fingerproof Covers, EMI Filter P6 Pushbutton Omitted Modification Catalog Description Adder P7 START/STOP Number U.S. $ P8 ON/OFF Suffix P9 START Fuse Blocks F4 Power Fuses Included — Order by P10 ON Description P11 OFF F5 30 Ampere Control Circuit Fuseholder P12 FORWARD/REVERSE/STOP (KTK) Mounted on Panel (Unwired), Fuse Not Supplied P13 FAST/SLOW/STOP F6 30 Ampere Control Circuit Fuseholder P14 FAST/OFF/SLOW Mounted on Panel (Unwired), FNQR P15 HIGH/LOW/STOP Fuse Supplied P16 HIGH/LOW F7 3-Pole Power Fuseholder Mounted on P17 SLOW/FAST Front Contactor P18 Pushbutton with Legend Plate F8 Separate Fusing of Control Power Supply P52 UP/STOP/DOWN F10 Blown Fuse Indicator (Not for PFC) P53 OPEN/STOP/CLOSE F21 Class CC Fuses Pilot Lights P19 With 1 Amber Pilot Light Marked POWER AVAILABLE Wired to Load Side of 2 Fuses or Circuit Breaker Table 34-226. G — Ground Fault Relay, Grounding P20 Pilot Light (Amber RUN) Wired to Coil Modification Catalog Description Adder Number U.S. $ P21 With 1 Red Pilot Light Marked RUN Suffix Wired thru NO Auxiliary Contact P22 With 1 Push-to-Test Red Light Marked Ground Fault G1 Ground Fault Relay (Wired) RUN Wired thru NO Auxiliary Contact Relay G3 Ground Fault Relay (Unwired) P23 Pilot Light — Red RUN Grounding G5 Special Grounding — Order by P24 Pilot Light — Red ON Description P25 Pilot Light — Green OFF G7 Ground Fault Protection and P26 Pilot Light — Order by Description Monitoring Panel P29 Pilot Light — Red STOP Table 34-227. H — Heater (Space) Modification Catalog Description Adder Number U.S. $ Suffix Space H1 Space Heater and Thermostat Heater H2 Space Heater and NC Interlock Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-199 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-229. P — Pilot Lights, Pushbuttons, Phase Relays, Potential Table 34-231. R — Ramp, Relays, Solid-State Electronic Overload Transformers, Power Factor Correction Capacitors, Program Timer, Relays, Resets, Overload Relay Modifications, Reversing, Percentage Timer, Photocell (Continued) DeviceNet Interface Modification Catalog Description Adder Modification Catalog Description Adder Number U.S. $ Number U.S. $ Suffix Suffix Relay R2 Overvoltage Relay Pilot Lights P61 Pilot Light — Green STOP (Continued) Solid-State IEC Full Load Current 3-Phase Automatic/ P62 FORWARD/REVERSE Red Pilot Lights 34 Electronic Frame Adjustment Range Manual Reset P63 UP/DOWN Red Pilot Lights Overload (A) Class 5/10/20/30 � Relay P64 OPEN/CLOSE Red Pilot Lights � Catalog Number Suffix R61_ ➟ P65 HIGH/LOW Red Pilot Lights B & C 0.1 – 0.5 A P66 FAST/SLOW Red Pilot Lights 0.4 – 2.0 B 1.0 – 5.0 C P67 Green RUN Light 1.6 – 8.0 D P68 LED Bulbs C & D 0.1 – 0.5 A P69 Blue OVERLOAD Light 0.4 – 2.0 B 1.0 – 5.0 C Illuminated P27 Illuminated Pushbutton — Order by 1.6 – 8.0 D Pushbutton Description 6.4 – 32 E Phase Loss P28 Phase Loss Relay D 9 – 45 F Relay 15 – 75 G Phase P30 Phase Reversal Relay F & G 22 – 110 H Reversal G 30 – 150 J Relay N/A 96 – 300 C Phase P32 Phase Unbalance Relay Unbalance N/A 192 – 600 C Relay Resets R5 Change External Reset to Internal Reset — Phase P34 Phase Monitoring Relay Hole Covered with Plug Monitoring R6 Internal Reset — No Hole Plug Relay R44 Manual Reset Only on Overload Relay Power Factor P38 /F1 20 kVar /F9 70 kVar /F17 200 kVar R45 Auto Reset Only on Overload Relay Correction /F2 25 kVar /F10 75 kVar /F18 225 kVar R47 Internal Trip Indicator — No External Reset Capacitors /F3 30 kVar /F11 80 kVar /F19 250 kVar /F4 35 kVar /F12 90 kVar /F20 300 kVar R71 N3R Reset Boot Added (Type 1/12 Only) /F5 40 kVar /F13 100 kVar /F21 350 kVar DeviceNet R69 DeviceNet Interface /F6 45 kVar /F14 125 kVar /F22 400 kVar Interface R65 Standard Reset for DeviceNet /F7 50 kVar /F15 150 kVar /F8 60 kVar /F16 175 kVar R66 Lighted Reset for DeviceNet Potential P39 Potential Transformer — Wired L1 – L2 R67 Trip Indicator for DeviceNet Transformers � P40 Potential Transformer — Wired L1– L2 Features: and L2 – L3 • Self-Powered • Phase Loss Protection P41 Potential Transformer — 3 Phases • Current Adjustment Knob Program P43 15-Minute Program Timer • ± 1% Repeat Accuracy Timers • 1NO and 1NC Isolated Contacts P44 24-Hour Program Timer � Complete Modification Code includes overload range. Example R61/C. P45 7-Day Program Timer with Day Omission Feature Percentage P47 15-Minute Percentage Timer Timers P48 60-Minute Percentage Timer Table 34-230. Q — IQ Products, DN50 Modification Catalog Description Adder Number U.S. $ Suffix IQ Products Q1 IQ 500 Q3 IQ 1000 Q5 IQ 4000 IQ Data Q12 IQ Data Metering Module Metering Q14 IQ 220 with Cable Module DN50 Q13 DeviceNet Input/Output Module Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-200 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-232. S — System Voltage, Selector Switches, Suppressor, Table 34-233. T — Timers, Time Delay Relays, Terminal Blocks, Incomplete Sequence Protection, Single-Phase Jumper, Surge Terminal Points, Ring Lug Connections Capacitor, Speed Potentiometer Modification Catalog Description Adder Modification Catalog Description Adder Number U.S. $ Number U.S. $ Suffix Suffix Timers T1 Pneumatic Timer Installed on Contac- System S1 System Voltage Selection for Internal tor, Unwired, 30 Sec. Max. Voltage Components T2 Pneumatic Timer Installed on Contac- Selection 34 /H1 208V 60 Hz tor, Unwired, 180 Sec. Max. /H2 240V 60 Hz /H3 277V 60 Hz, 1-Ph T3 Pneumatic Timer Mounted in Enclo- /H4 480V 60 Hz sure, Unwired, 180 Sec. Max. /H5 600V 60 Hz T4 Solid-State ON Delay Timer /H6 796V 60 Hz (1 – 30 Sec.) /H7 220V 50 Hz /H8 380V 50 Hz T5 Solid-State ON Delay Timer /H9 415V 50 Hz (30 – 300 Sec.) /H10 550V 50 Hz T25 Timer — Order by Description /H11 660V 50 Hz /H12 380V 60 Hz Time Delay T6 Time Delay Relay, 3 Minutes Maximum, /H13 1500V 60 Hz Relays Unwired, ON DELAY S2 System Voltage Selection — Specify on T7 Time Delay Relay, 3 Minutes Maximum, Order Unwired, OFF DELAY Selector S3 HAND/OFF/AUTO � T8 Time Delay Low Voltage Release Relay Switches S4 HAND/AUTO Terminal T9 With 1 Single Circuit Terminal Block, S5 HAND/OFF/AUTO Selector Switch with 1 Blocks Unwired Red RUN Pilot Light T10 With 2 Single Circuit Terminal Block, S6 RUN/OFF/AUTO Unwired S7 AUTO/OFF/TEST T24 Power Terminal Block for DeviceNet S8 AUTO/OFF/TEST Selector Switch with 1 Overload Red RUN Pilot Light Terminal T11 With 6 Terminal Points, Unwired S9 AUTO/OFF/TEST Selector Switch with 1 Points T12 With 12 Terminal Points, Unwired Red RUN Pilot Light and 1 Green Pilot Light T13 With 18 Terminal Points, Unwired S10 OFF/AUTO T14 Terminal Point per Customer S11 START/STOP Specification, Unwired (Price Each) S12 OFF/ON T15 Terminal Point per Customer Specification, Wired (Price Each) S13 HIGH/LOW T21 3 Terminals Mounted Between S14 FAST/OFF/SLOW Contactor and Overload for Power S15 SLOW/FAST Factor Capacitors — Sizes 0 – 2 S16 FORWARD/REVERSE T22 3 Terminals Mounted Between S17 HIGH/OFF/LOW Contactor and Overload for Power Factor Capacitors — Sizes 3 – 4 S18 HIGH/LOW/OFF/AUTO Ring Lug T17 Ring Lug Connections on Control Wires S21 HAND/OFF/AUTO Spring Return from Left Connections S41 OPEN/OFF/CLOSE S42 FORWARD/OFF/REVERSE Table 34-234. U — Undervoltage Relay, Time Delay Undervoltage Relay S43 FAST/OFF/SLOW/AUTO Modification Catalog Description Adder S40 Selector Switch — Order by Description Number U.S. $ Suppressor S24 Transient Suppressor Mounted Suffix on Magnet Coil Undervoltage U1 Undervoltage Relay, Non-adjustable Sequence S26 Sequence Timer (Pump Panels) Relays Timer U2 Undervoltage Relay, Adjustable Sequence S27 Incomplete Sequence Protection Time Delay U4 Time Delay Undervoltage Relay, Protection Undervoltage Non-adjustable Single S29 Convert Contactor or Starter from Three- Relays U5 Time Delay Undervoltage Relay, Phase Phase to Single-Phase — Install Jumper Adjustable S30 Single-Phase Rev. 120V Under- and U7 Under- and Overvoltage Relay S31 Single-Phase Rev. 240V Overvoltage � Relay When using 3-position selector switch with magnetic lighting contactor, mod C20 must also be used (ECL04, ECL13, ECL15). Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-201 XT IEC Power Control March 2009 Contactors and Starters — Enclosed Control Table 34-235. V — Voltmeter, Varmeter, Vacuum Starter Table 34-236. W — Wattmeter, Watt-Hour Meter, Wiremarkers, Wiring Diagram Modification Catalog Description Adder Number U.S. $ Modification Catalog Description Adder Suffix Number U.S. $ Suffix Voltmeters V1 1 Panel Type Voltmeter Wired L1 – L2 Wattmeter W1 Wattmeter V2 Panel Type Voltmeter and Selector Switch Wired to Read Three Line Watt-Hour W3 Watt-Hour Meter Voltages Meter 34 W5 Watt-Hour Meter with Demand V3 Miniature Voltmeter Wired L1 – L2 Attachment V4 Miniature Voltmeter and Selector Wiremarkers W7 Wiremarkers Switch Wired to Read Three Line W8 Wiremarkers — Order per Customer Voltages Diagram or Specifications V5 Switchboard Type Voltmeter Wired W9 Wiremarkers — Order by Description L1 – L2 Wiring W12 Reduced Copy of Custom Wiring V6 Switchboard Type Voltmeter and Diagram Diagram Laminated on Inside of Door Selector Switch Wired to Read Three Line Voltage V7 3 Panel Type Voltmeters Wired in Each Phase V8 3 Miniature Voltmeters Wired in Each Phase V9 3 Switchboard Type Voltmeters Wired in Each Phase V10 Voltmeter — Order by Description Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-202 XT IEC Power Control March 2009 Combination Motor Controllers — Enclosed Control Contents Features and Benefits Short Circuit Ratings Description Page ■ ON/OFF rotary handle with lockout ■ 0 – 12A/B-frame MMP with B-frame provision contactor Cover Control . . . . . . . . . . . . . 34-204 ■ Visible trip indication ❑ 50K AIC @ 600V Catalog Number ■ Test trip function ■ 13 – 32A/B-frame MMP with C-frame Selection . . . . . . . . . . . . . . . 34-203 contactor ■ Motor applications from 0.11A Product Selection . . . . . . . . . 34-206 34 to 32A ❑ 18K AIC @ 600V Dimensions . . . . . . . . . . . . . . 34-209 ■ Class 10 overload protection Modification Codes . . . . . . . . 34-196 ■ Built-in heater and magnetic trip Standards and Certifications Reference Data . . . . . . . . . . . . 34-210 elements to protect the motor Note: See Enclosed Control Product Guide ■ Phase loss sensitivity PG03300001E for additional information on ■ Type 2 coordination Standards and Certifications that apply to ■ Ambient compensated up to 55°C all Cutler-Hammer Enclosed Control products. [140°F] ■ Control inputs located at front of ■ UL Listed starter for easy access and wiring ■ cUL Listed (indicates appropriate ■ Wide range of coils CSA Standard investigation) ■ DIN Rail mount — XTSC…BB_ ■ Mounting plates — XTSC…BC_, XTSC…D motor controllers ■ Adjustment dial for setting motor FLA Enclosed XT CMC ■ Short circuit trip at 14 times the maximum setting of the FLA adjustment dial Product Description ■ UL 508 Type F CMC High Fault Short Circuit Ratings: Refer to Manual ® Eaton’s Cutler-Hammer XT Line Motor Protectors in CA08102001E. includes IEC Contactors, Starters and ■ Nonmetallic and metallic enclosures Combination Motor Controllers in Types 1 (IP23), 4 (IP66), 4X (IP66) (CMCs). Designed to meet International and 12 (IP65) Standards, the Enclosed Control XT Line (ECX) carries UL and cUL ■ Opaque (standard) or clear covers certifications. available on nonmetallic Halyester enclosure For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-203 XT IEC Power Control March 2009 Combination Motor Controllers — Enclosed Control Catalog Number Selection Table 34-237. Combination Motor Controllers — Enclosed Control Catalog Numbering System E C X 7 6 D 4 B A A - Design Modification Codes X = XT IEC See PG03300001E 34 Class Table MMP Overload Range 76 = Combination Motor Controller (CMC) — 34-241 See Table 34-238 Non-reversing Starter 77 = Combination Motor Controller (CMC) — 34-242 Disconnect Ratings Non-reversing Starter with CPT A = None 78 = Combination Motor Controller (CMC) — 34-243 Reversing Starter Cover Control See Table 34-239 Frame Size D = 12A H = 32A Coil Voltage A = 120V B = 240V � Enclosure Type/IP Ratings C = 480V 1 = Type 1 — General Purpose D = 600V 3 = Type 4 — Painted Steel E = 208V 4 = Type 4X — Watertight (304-Grade SS) L = 380V/50 Hz 5 = Type 4X — Watertight Nonmetallic 8 = Type 12 — Dust-Tight � See PG03300001E for Enclosure Type/IP Rating Cross-Reference. Table 34-238. XTPR MMP Amperage Ranges XT MMP Overload Enclosed Control Catalog Number Amp Range Suffix Code Frame B Rotary MMP XTPRP16BC1 .1 – .16 A XTPRP25BC1 .16 – .25 B XTPRP40BC1 .25 – .4 C XTPRP63BC1 .4 – .63 D XTPR001BC1 .63 – 1 E XTPR1P6BC1 1 – 1.6 F XTPR2P5BC1 1.6 – 2.5 G XTPR004BC1 2.5 – 4 H XTPR6P3BC1 4 – 6.3 J XTPR010BC1 6.3 – 10 K XTPR012BC1 8 – 12.0 L XTPR016BC1 10 – 16.0 M XTPR020BC1 16 – 20 N XTPR025BC1 20 – 25 Q XTPR032BC1 25 – 32 R CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-204 XT IEC Power Control March 2009 Combination Motor Controllers — Enclosed Control Table 34-239. 10250T Style Combination Cover Control Cover Control Description Factory Installed Field Installation Kits Flange Control ■ Cover control for Combination Motor Control Starters uses the 10250T Position Combination 9 Alpha (30 mm) family. Catalog Price Number U.S. $ ■ E22 style cover control is an avail- Non-reversing able option. ■ Selector switches are maintained No Cover Mounted Pilot Devices A — 34 START/STOP Pushbuttons B C400T1 with lever operators. with Red RUN Pilot Light C — ■ Pushbuttons are momentary type with Red RUN/Green OFF Lights D — with extended pushbutton. ON/OFF Pushbuttons E C400T2 ■ The kit includes hardware and with Red RUN Pilot Light F — with Red RUN/Green OFF Lights G — connecting wires (where possible). HAND/OFF/AUTO Selector Switch H C400T12 ■ For factory installed control devices with Red RUN Pilot Light J — other than shown below, refer to with Red RUN/Green OFF Lights K — Modification Codes, PG03300001E. START Pushbutton L C400T3 ON Pushbutton M C400T4 OFF Pushbutton N C400T5 � Red RUN Pilot Light P C400T9 � Green OFF Q C400T10 � Red RUN/Green OFF Pilot Lights R C400T11 START/STOP Selector Switch S C400T13 with Red RUN Pilot Light T — with Red RUN/Green OFF Lights U — ON/OFF Selector Switch V C400T14 with Red RUN Pilot Light W — with Red RUN/Green OFF Lights X — Reversing No Cover Mounted Pilot Devices A — FOR/REV/STOP Pushbuttons B C400T6 with 2 Red Pilot Lights C — with 2 Red/1 Green Pilot Lights D — UP/STOP/DOWN Pushbuttons E — with 2 Red Pilot Lights F — FOR/OFF/REV Selector Switch H C400T15 with 2 Red Pilot Lights J — with 2 Red/1 Green Pilot Lights K — � Two Red Pilot Lights P � One Green Pilot Light Q C400T10 Two Red/One Green Pilot Lights R — OPEN/OFF/CLOSE Selector Switch V C400T16 with 2 Red Pilot Lights W — with 2 Red/1 Green Pilot Lights X — � Add Code Letter from the table below to Catalog Number for voltage — Kits only. Example: C400T9B. Rating Code Letter Rating Code Letter Rating Code Letter 120V 60 Hz A 240V 60 Hz B 480V 60 Hz C 208V 60 Hz E 380V 50 Hz L 600V 60 Hz D � Order Quantity (2) of C400T10. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-205 XT IEC Power Control March 2009 Combination Motor Controllers — Enclosed Control Table 34-240. E22 Style Combination Motor Controller Cover Control � Description Factory Installed Field Kits Position 9 Combination Cover Only Control Catalog Price Code Number U.S. $ Non-reversing START/STOP Pushbuttons (PB) B CE400T01 34 � START/STOP PB & Red RUN Light C CE400T02 � START/STOP PB, Red RUN, & Green STOPPED Light D CE400T03 HAND/OFF/AUTO Selector Switch (SS) H CE400T04 � H-O-A SS & Red RUN Light J CE400T05 � H-O-A SS, Red RUN, & Green STOPPED Light K CE400T06 � Red RUN Pilot Light P CE400T10 � Green Off Pilot Light Q CE400T11 � Red RUN/Green OFF Pilot Light R CE400T12 ON/OFF Selector Switch (SS) S CE400T07 � ON/OFF SS, Red RUN Light T CE400T08 � ON/OFF SS, Red RUN, & Green STOPPED Light U CE400T09 Reversing FWD/REV/STOP Pushbuttons (PB) B CE400T50 � FWD/REV/STOP PB + Red FWD & REV Lights C CE400T51 � FWD/REV/STOP PB, Red FWD/REV, & Green STOPPED D CE400T52 FOR/OFF/REV Selector Switch (SS) H CE400T53 � FOR/OFF/REV SS + Red FWD & REV Lights J CE400T54 � FOR/OFF/REV SS, Red FWD/REV, & Green STOPPED K CE400T55 OPEN/OFF/CLOSE Selector Switch (SS) V CE400T56 � OPEN/OFF/CLOSE SS + Red FWD & REV Lights W CE400T57 � OPEN/OFF/CLOSE SS, Red FWD/REV, & Green STOPPED X CE400T58 � To include any of the above cover controls, place the control code character in position 9 of your Catalog Number and add Mod Code P74. Example: ECX77H1ADA-P74. Full voltage non-reversing fusible starter with interchangeable heater OLR and START/STOP pushbutton with red RUN and green OFF pilot lights. � Suffix for lights (required for field installed kits only) in the table below: Rating Catalog Rating Catalog Suffix Suffix 120V 60 Hz A 277V 60 Hz H 208V 60 Hz E 380V 50 Hz L 240V 60 Hz B 460V 60 Hz C 600V 60 Hz D Note: All CMC design built in enclosure Size 5 do not contain a CPT. In order to supply internal power for cover control, the enclosure must increase to Size 6. If control power is to be supplied from a source outside of the enclosure, there is no need to oversize. Note that 32A and less FVNR designs permit room for a 24V DC power supply to be installed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-206 XT IEC Power Control March 2009 Combination Motor Controllers — Enclosed Control Product Selection Table 34-241. Class ECX76 — Combination Motor Controller (CMC) — Non-reversing Starter � � �� � Size Amps Maximum hp Coil voltage @ 60 Hz Type 1/IP23 Type 4X/IP66 Component General Purpose Watertight Motor Voltage 1-phase 3-phase Catalog Price Catalog Price Catalog Number U.S. $ Number U.S. $ Number D 12 115 1/2 — 120 ECX76D1AAA-_ ECX76D4AAA-_ XTPR_ _ _BC1 34 208 1-1/2 3 208 ECX76D1EAA-_ ECX76D4EAA-_ 230 2 3 240 ECX76D1BAA-_ ECX76D4BAA-_ 380 — 5 380/50 Hz ECX76D1LAA-_ ECX76D4LAA-_ 460 — 7-1/2 480 ECX76D1CAA-_ ECX76D4CAA-_ 575 — 10 600 ECX76D1DAA-_ ECX76D4DAA-_ H 32 115 3 — 120 ECX76H1AAA-_ ECX76H4AAA-_ XTPR_ _ _BC1 208 5 10 208 ECX76H1EAA-_ ECX76H4EAA-_ 230 5 10 240 ECX76H1BAA-_ ECX76H4BAA-_ 380 — 15 380/50 Hz ECX76H1LAA-_ ECX76H4LAA-_ 460 — 20 480 ECX76H1CAA-_ ECX76H4CAA-_ 575 — 25 600 ECX76H1DAA-_ ECX76H4DAA-_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 34-203. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX76D4AAA-_. To order Type 4 Painted Steel, change that digit to 3. � Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions. Table 34-241. Class ECX76 — Combination Motor Controller (CMC) — Non-reversing Starter (Continued) � � � Size Amps Maximum hp Coil voltage @ 60 Hz Type 4X Nonmetallic/IP66 Type 12/IP65 Component � Watertight Dust-Tight Motor Voltage 1-phase 3-phase Catalog Price Catalog Price Catalog Number U.S. $ Number U.S. $ Number D 12 115 1/2 — 120 ECX76D5AAA-_ ECX76D8AAA-_ XTPR_ _ _BC1 208 1-1/2 3 208 ECX76D5EAA-_ ECX76D8EAA-_ 230 2 3 240 ECX76D5BAA-_ ECX76D8BAA-_ 380 — 5 380/50 Hz ECX76D5LAA-_ ECX76D8LAA-_ 460 — 7-1/2 480 ECX76D5CAA-_ ECX76D8CAA-_ 575 — 10 600 ECX76D5DAA-_ ECX76D8DAA-_ H 32 115 3 — 120 ECX76H5AAA-_ ECX76H8AAA-_ XTPR_ _ _BC1 208 5 10 208 ECX76H5EAA-_ ECX76H8EAA-_ 230 5 10 240 ECX76H5BAA-_ ECX76H8BAA-_ 380 — 15 380/50 Hz ECX76H5LAA-_ ECX76H8LAA-_ 460 — 20 480 ECX76H5CAA-_ ECX76H8CAA-_ 575 — 25 600 ECX76H5DAA-_ ECX76H8DAA-_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 34-203. � Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions. Cover Control . . . . . . . . . . . . . . . . . . . . Page 34-204 Dimensions . . . . . . . . . . . . . . . . . . . . . . PG03300001E Modifications Codes. . . . . . . . . . . . . . PG03300001E Technical Data, MMPs . . . . . . . . . . . CA08102001E Technical Data, Contactors . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-207 XT IEC Power Control March 2009 Combination Motor Controllers — Enclosed Control Table 34-242. Class ECX77 — Combination Motor Controller (CMC) — Non-reversing Starter with CPT � � �� � Size Amps Maximum hp Coil voltage @ 60 Hz Type 1/IP23 Type 4X/IP66 Component General Purpose Watertight Motor Voltage 1-phase 3-phase Catalog Price Catalog Price Catalog Number U.S. $ Number U.S. $ Number D 12 115 1/2 — 120 ECX77D1AAA-_ ECX77D4AAA-_ XTPR_ _ _BC1 208 1-1/2 3 208 ECX77D1EAA-_ ECX77D4EAA-_ 230 2 3 240 ECX77D1BAA-_ ECX77D4BAA-_ 34 380 — 5 380/50 Hz ECX77D1LAA-_ ECX77D4LAA-_ 460 — 7-1/2 480 ECX77D1CAA-_ ECX77D4CAA-_ 575 — 10 600 ECX77D1DAA-_ ECX77D4DAA-_ H 32 115 3 — 120 ECX77H1AAA-_ ECX77H4AAA-_ XTPR_ _ _BC1 208 5 10 208 ECX77H1EAA-_ ECX77H4EAA-_ 230 5 10 240 ECX77H1BAA-_ ECX77H4BAA-_ 380 — 15 380/50 Hz ECX77H1LAA-_ ECX77H4LAA-_ 460 — 20 480 ECX77H1CAA-_ ECX77H4CAA-_ 575 — 25 600 ECX77H1DAA-_ ECX77H4DAA-_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 34-203. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX77D4AAA-_. To order Type 4 Painted Steel, change that digit to 3. � Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions. Table 34-242. Class ECX77 — Combination Motor Controller (CMC) — Non-reversing Starter with CPT (Continued) � � � Size Amps Maximum hp Coil voltage @ 60 Hz Type 4X Nonmetallic/ Type 12/IP65 Component � IP66 Watertight Dust-Tight Motor Voltage 1-phase 3-phase Catalog Price Catalog Price Catalog Number U.S. $ Number U.S. $ Number D 12 115 1/2 — 120 ECX77D5AAA-_ ECX77D8AAA-_ XTPR_ _ _BC1 208 1-1/2 3 208 ECX77D5EAA-_ ECX77D8EAA-_ 230 2 3 240 ECX77D5BAA-_ ECX77D8BAA-_ 380 — 5 380/50 Hz ECX77D5LAA-_ ECX77D8LAA-_ 460 — 7-1/2 480 ECX77D5CAA-_ ECX77D8CAA-_ 575 — 10 600 ECX77D5DAA-_ ECX77D8DAA-_ H 32 115 3 — 120 ECX77H5AAA-_ ECX77H8AAA-_ XTPR_ _ _BC1 208 5 10 208 ECX77H5EAA-_ ECX77H8EAA-_ 230 5 10 240 ECX77H5BAA-_ ECX77H8BAA-_ 380 — 15 380/50 Hz ECX77H5LAA-_ ECX77H8LAA-_ 460 — 20 480 ECX77H5CAA-_ ECX77H8CAA-_ 575 — 25 600 ECX77H5DAA-_ ECX77H8DAA-_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 34-203. � Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions. Cover Control . . . . . . . . . . . . . . . . . . . . Page 34-204 Dimensions. . . . . . . . . . . . . . . . . . . . . . PG03300001E Modifications Codes . . . . . . . . . . . . . PG03300001E Technical Data, MMPs . . . . . . . . . . . CA08102001E Technical Data, Contactors . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-208 XT IEC Power Control March 2009 Combination Motor Controllers — Enclosed Control Table 34-243. Class ECX78 — Combination Motor Controller (CMC) — Reversing Starter � � �� � Size Amps Maximum hp Coil voltage @ 60 Hz Type 1/IP23 Type 4X/IP66 Component General Purpose Watertight Motor Voltage 1-phase 3-phase Catalog Price Catalog Price Catalog Number U.S. $ Number U.S. $ Number D 12 115 1/2 — 120 ECX78D1AAA-_ ECX78D4AAA-_ XTPR_ _ _BC1 208 1-1/2 3 208 ECX78D1EAA-_ ECX78D4EAA-_ 230 2 3 240 ECX78D1BAA-_ ECX78D4BAA-_ 34 380 — 5 380/50 Hz ECX78D1LAA-_ ECX78D4LAA-_ 460 — 7-1/2 480 ECX78D1CAA-_ ECX78D4CAA-_ 575 — 10 600 ECX78D1DAA-_ ECX78D4DAA-_ H 32 115 3 — 120 ECX78H1AAA-_ ECX78H4AAA-_ XTPR_ _ _BC1 208 5 10 208 ECX78H1EAA-_ ECX78H4EAA-_ 230 5 10 240 ECX78H1BAA-_ ECX78H4BAA-_ 380 — 15 380/50 Hz ECX78H1LAA-_ ECX78H4LAA-_ 460 — 20 480 ECX78H1CAA-_ ECX78H4CAA-_ 575 — 25 600 ECX78H1DAA-_ ECX78H4DAA-_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 34-203. � These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX78D4AAA-_. To order Type 4 Painted Steel, change that digit to 3. � Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions. Table 34-243. Class ECX78 — Combination Motor Controller (CMC) — Reversing Starter (Continued) � � � Size Amps Maximum hp Coil voltage @ 60 Hz Type 4X Nonmetallic/ Type 12/IP65 Component � IP66 Watertight Dust-Tight Motor Voltage 1-phase 3-phase Catalog Price Catalog Price Catalog Number U.S. $ Number U.S. $ Number D 12 115 1/2 — 120 ECX78D5AAA-_ ECX78D8AAA-_ XTPR_ _ _BC1 208 1-1/2 3 208 ECX78D5EAA-_ ECX78D8EAA-_ 230 2 3 240 ECX78D5BAA-_ ECX78D8BAA-_ 380 — 5 380/50 Hz ECX78D5LAA-_ ECX78D8LAA-_ 460 — 7-1/2 480 ECX78D5CAA-_ ECX78D8CAA-_ 575 — 10 600 ECX78D5DAA-_ ECX78D8DAA-_ H 32 115 3 — 120 ECX78H5AAA-_ ECX78H8AAA-_ XTPR_ _ _BC1 208 5 10 208 ECX78H5EAA-_ ECX78H8EAA-_ 230 5 10 240 ECX78H5BAA-_ ECX78H8BAA-_ 380 — 15 380/50 Hz ECX78H5LAA-_ ECX78H8LAA-_ 460 — 20 480 ECX78H5CAA-_ ECX78H8CAA-_ 575 — 25 600 ECX78H5DAA-_ ECX78H8DAA-_ � 1 hp = 0.746 kW. � Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. � Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 34-203. � Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions. Cover Control . . . . . . . . . . . . . . . . . . . . Page 34-204 Dimensions . . . . . . . . . . . . . . . . . . . . . . PG03300001E Modifications Codes. . . . . . . . . . . . . . PG03300001E Technical Data, MMPs . . . . . . . . . . . CA08102001E Technical Data, Contactors . . . . . . . PG03300001E Discount Symbol . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-209 XT IEC Power Control March 2009 Combination Motor Controllers — Enclosed Control Dimensions Type 1, 3R, 4, 4X, 12 XT HMCP Type 1, 3R, 4, 4X, 12 XT Combination Box Dimensions Combination Starters Motor Controllers (CMCs) For Box Dimensions, See Enclosed Control Product Guide, PG03300001E. Table 34-244. Class 25 — FVNR Combination Table 34-246. Class 76 — Self Protected with HMCP Starter (CMC) IEC Size Box Ship Weight IEC Size Box Ship Weight 34 (Frame / Amps) Number in kg [Lb] (Frame/Amps) Number kg [lbs] B – H / 7 – 32A 7A 10 [23] B – H/up to 32A K 6.8 [15] B – H / 7 – 32A 7P 8.2 [18] B – H/up to 32A 5P 5.4 [12] J – L / 40 – 65A 7A 11 [24] Table 34-247. Class 77 — Self Protected J – L / 40 – 65A 7P 8.9 [20] Starter (CMC) with CPT M – Q / 80 – 125A 8 31.8 [70] IEC Size Box Ship Weight Table 34-245. Class 26 — FVR Combination (Frame/Amps) Number kg [lbs] with HMCP B – H/up to 32A K 9.5 [21] IEC Size Box Ship Weight B – H/up to 32A 6P 7.0 [17] (Frame / Amps) Number in kg [Lb] B – H / 7 – 32A 7A 12 [26] Table 34-248. Class 78 — Reversing Self B – H / 7 – 32A 7P 10 [22] Protected Starter (CMC) J – L / 40 – 65A 7A 13 [29] IEC Size Box Ship Weight J – L / 40 – 65A 7P 11 [25] (Frame/Amps) Number kg [lbs] M – P / 80 – 115A 8 31.8 [70] B – H/7 – 32A K 7.0 [16] B – H/7 – 32A 5P 5.2 [12] CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-210 XT IEC Power Control March 2009 Reference Data voltage switchgear and controlgear — Type 2 Coordination requires that Type 2 Coordination Part 4-1: Contactors and motor-starters under short circuit conditions, the con- — Electromechanical contactors and tactor or starter shall cause no danger What is it? motor-starters: to persons or installation and shall be The International Electrotechnical suitable for further use. The risk of Type 1 Coordination requires that Commission (IEC) developed short contact welding is recognized, in which under short circuit conditions, the con- circuit performance criteria for case the manufacturer shall indicate tactor or starter shall cause no danger contactors and starters called Type 1 the measures to be taken as regards to to persons or installation and may not 34 coordination and Type 2 coordination. the maintenance of the equipment. be suitable for further service without This defines motor controller protec- repair and replacement of parts. In this case, the contactor/starter is tion levels following a short circuit able to continue use after the occur- fault. In order to achieve this perfor- In this case, significant damage is rence of a short circuit fault. Light mance, the combination of a motor allowed to the contactor/starter (e.g. contact burning or tack welding may controller (contactor or starter) and contact welding, burning, or disinte- occur provided the contacts are easily short circuit protective device (manual gration) and the overload relay (e.g. separable. motor protector, circuit breaker or component harm or heater element fuse) must meet the following criteria burn-out). as specified by IEC 60947-4-1 — Low Table 34-249. 400, 415V Type 2 Coordination — MMC P I I MMP Contactor MMC e q � � (kW) (A) (kA) Catalog Number Catalog Number Catalog Number � 0.06 0.21 50 (150) XTPRP25BC1 XTCE007B10_ XTSCP25BB_ � 0.09 0.31 50 (150) XTPRP40BC1 XTCE007B10_ XTSCP40BB_ � 0.12 0.41 50 (150) XTPRP63BC1 XTCE007B10_ XTSCP63BB_ � 0.18 0.60 50 (150) XTPRP63BC1 XTCE007B10_ XTSCP63BB_ � 0.25 0.80 50 (150) XTPR001BC1 XTCE007B10_ XTSC001BB_ � 0.37 1.10 50 (150) XTPR1P6BC1 XTCE007B10_ XTSC1P6BB_ � 0.55 1.50 50 (150) XTPR1P6BC1 XTCE007B10_ XTSC1P6BB_ � 0.75 1.90 50 (150) XTPR2P5BC1 XTCE007B10_ XTSC2P5BB_ � 1.10 2.60 50 (150) XTPR004BC1 XTCE007B10_ XTSC004BB_ � 1.50 3.60 50 (150) XTPR004BC1 XTCE007B10_ XTSC004BB_ � 2.20 5.00 50 (150) XTPR6P3BC1 XTCE007B10_ XTSC6P3BB_ � 3.00 6.60 50 (150) XTPR010BC1 XTCE018C10_ XTSC010BC_ � 4.00 8.50 50 (150) XTPR010BC1 XTCE018C10_ XTSC010BC_ 5.50 11.3 50 XTPR012BC1 XTCE018C10_ XTSC012BC_ 7.50 16.0 50 XTPR016BC1 XTCE018C10_ XTSC016BC_ 11.0 21.7 50 XTPR025BC1 XTCE025C10_ XTSC025BC_ 15.0 29.3 50 XTPR032BC1 XTCE032C10_ XTSC032BC_ 5.50 11.3 50 XTPR016DC1 XTCE018C10_ XTSC016DC_ 7.50 16.0 50 XTPR016DC1 XTCE018C10_ XTSC016DC_ 11.0 21.7 50 XTPR025DC1 XTCE025C10_ XTSC025DC_ 15.0 29.3 50 XTPR032DC1 XTCE032C10_ XTSC032DC_ 18.5 36.0 50 XTPR040DC1 XTCE040D00_ XTSC040DD_ 22.0 41.0 50 XTPR050DC1 XTCE050D00_ XTSC050DD_ 30.0 55.0 50 XTPR058DC1 XTCE065D00_ XTSC058DD_ 34.0 63.0 50 XTPR063DC1 XTCE065D00_ XTSC063DD_ � Values in parentheses ( ) are for Type 1 Coordination. � Underscore (_) indicates magnet coil suffix required. See Table 34-261, Page 34-216. Note: See Page 34-216 for more information on Wye-Delta (Star Delta) applications. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-211 XT IEC Power Control March 2009 Reference Data Table 34-250. 480V Type 2 Coordination — MMC P I I MMP Current Limiter Contactor MMC e q � � (hp) (A) (kA) Catalog Number Catalog Number Catalog Number Catalog Number 1/2 0.24 65 XTPRP25BC1 XTCE007B10_ XTSCP25BB_ 1/2 0.32 65 XTPRP40BC1 XTCE007B10_ XTSCP40BB_ 1/2 0.51 65 XTPRP63BC1 XTCE007B10_ XTSCP63BB_ 1/2 0.74 65 XTPR001BC1 XTCE007B10_ XTSC001BB_ 34 1/2 0.94 65 XTPR001BC1 XTCE007B10_ XTSC001BB_ 3/4 1.32 65 XTPR1P6BC1 XTCE007B10_ XTSC1P6BB_ 1 1.72 65 XTPR2P5BC1 XTCE018C10_ XTSC2P5BC_ 2 2.55 65 XTPR004BC1 XTCE018C10_ XTSC004BC_ 2 3.10 65 XTPR004BC1 XTCE018C10_ XTSC004BC_ � 3 4.55 65 (50) XTPR6P3BC1 XTPAXCL XTCE018C10_ XTSC6P3BC_ � 3 6.15 65 (50) XTPR6P3BC1 XTPAXCL XTCE018C10_ XTSC6P3BC_ � 7-1/2 8.40 65 (50) XTPR010BC1 XTPAXCL XTCE018C10_ XTSC010BC_ � 7-1/2 11.0 65 (50) XTPR012BC1 XTPAXCL XTCE018C10_ XTSC012BC_ � 10 14.5 65 (50) XTPR016BC1 XTPAXCL XTCE018C10_ XTSC016BC_ � 10 20.0 65 (50) XTPR020BC1 XTPAXCL XTCE025C10_ XTSC020BC_ 20 20.0 65 XTPR025DC1 XTCE040D00_ XTSC025DD_ 25 27.0 65 XTPR032DC1 XTCE040D00_ XTSC032DD_ 25 32.0 65 XTPR032DC1 XTCE040D00_ XTSC032DD_ 30 37.5 65 XTPR040DC1 XTCE040D00_ XTSC040DD_ 40 40.5 65 XTPR050DC1 XTCE050D00_ XTSC050DD_ 40 50.5 65 XTPR058DC1 XTCE065D00_ XTSC058DD_ 40 64.0 65 XTPR063DC1 XTCE065D00_ XTSC063DD_ � Values in parentheses ( ) are achieved without the current limiter. � Underscore (_) indicates magnet coil suffix required. See Table 34-261, Page 34-216. Note: See Page 34-216 for more information on Wye-Delta (Star Delta) applications. Table 34-251. 600V Type 2 Coordination — MMC P I I MMP Current Limiter Contactor MMC e q � � (hp) (A) (kA) Catalog Number Catalog Number Catalog Number Catalog Number 1/2 0.19 50 XTPRP25BC1 XTCE007B10_ XTSCP25BB_ 1/2 0.26 50 XTPRP40BC1 XTCE007B10_ XTSCP40BB_ 1/2 0.41 50 XTPRP63BC1 XTCE007B10_ XTSCP63BB_ 1/2 0.59 50 XTPRP63BC1 XTCE007B10_ XTSCP63BB_ 1/2 0.75 50 XTPR001BC1 XTCE007B10_ XTSC001BB_ 1 1.06 50 XTPR1P6BC1 XTCE007B10_ XTSC1P6BB_ 1 1.38 50 XTPR1P6BC1 XTCE007B10_ XTSC1P6BB_ 1-1/2 2.04 50 XTPR2P5BC1 XTCE018C10_ XTSC2P5BC_ 1-1/2 2.48 50 XTPR2P5BC1 XTCE018C10_ XTSC2P5BC_ 3 3.64 50 XTPR004BC1 XTCE018C10_ XTSC004BC_ � 5 4.92 50 (18) XTPR6P3BC1 XTPAXCL XTCE018C10_ XTSC6P3BC_ � 10 6.72 50 (18) XTPR010BC1 XTPAXCL XTCE018C10_ XTSC010BC_ � 10 8.60 50 (18) XTPR010BC1 XTPAXCL XTCE018C10_ XTSC010BC_ � 10 11.5 50 (18) XTPR012BC1 XTPAXCL XTCE018C10_ XTSC012BC_ � 10 16.0 50 (18) XTPR016BC1 XTPAXCL XTCE018C10_ XTSC016BC_ 25 21.5 50 XTPR025DC1 XTCE040D00_ XTSC025DD_ 30 25.5 50 XTPR032DC1 XTCE040D00_ XTSC032DD_ 30 30.0 50 XTPR032DC1 XTCE040D00_ XTSC032DD_ 30 37.5 50 XTPR040DC1 XTCE040D00_ XTSC050DD_ 40 40.5 50 XTPR050DC1 XTCE050D00_ XTSC050DD_ 40 51.0 42 XTPR058DC1 XTCE065D00_ XTSC058DD_ 50 61.0 42 XTPR063DC1 XTCE065D00_ XTSC063DD_ � Values in parentheses ( ) are achieved without the current limiter. � Underscore (_) indicates magnet coil suffix required. See Table 34-261, Page 34-216. Note: See Page 34-216 for more information on Wye-Delta (Star Delta) applications. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-212 XT IEC Power Control March 2009 Reference Data Table 34-252. 400, 415V Type 2 Coordination — Contactor and Overload Relay (Motor Starter) with Fused Disconnect P I I Fuses Contactor Overload Relay Assembled Starter e q � � (kW) (A) (kA) Class gG/gL Catalog Number Catalog Number Catalog Number 0.12 0.41 100 2 XTCE007B10_ XTOBP60BC1 XTAE007B10_P60 0.18 0.60 100 2 XTCE007B10_ XTOB001BC1 XTAE007B10_001 0.25 0.80 100 4 XTCE007B10_ XTOB001BC1 XTAE007B10_001 0.37 1.10 100 4 XTCE007B10_ XTOB1P6BC1 XTAE007B10_1P6 0.55 1.50 100 4 XTCE007B10_ XTOB1P6BC1 XTAE007B10_1P6 34 0.75 1.90 100 6 XTCE007B10_ XTOB2P4BC1 XTAE007B10_2P4 1.10 2.60 100 6 XTCE007B10_ XTOB004BC1 XTAE007B10_004 1.50 3.60 100 6 XTCE007B10_ XTOB004BC1 XTAE007B10_004 2.20 5.00 100 10 XTCE007B10_ XTOB006BC1 XTAE007B10_006 3.00 6.60 100 16 XTCE007B10_ XTOB010BC1 XTAE007B10_010 4.00 8.50 100 20 XTCE009B10_ XTOB010BC1 XTAE009B10_010 5.50 11.3 100 25 XTCE018C10_ XTOB016CC1 XTAE018C10_016 7.50 16.0 100 32 XTCE018C10_ XTOB016CC1 XTAE018C10_016 11.0 21.7 100 40 XTCE025C10_ XTOB024CC1 XTAE032C10_024 15.0 29.3 100 63 XTCE032C10_ XTOB032CC1 XTAE032C10_032 18.5 36.0 100 63 XTCE040D00_ XTOB040DC1 XTAE040D00_040 22.0 41.0 100 80 XTCE050D00_ XTOB057DC1 XTAE065D00_057 30.0 55.0 100 100 XTCE065D00_ XTOB057DC1 XTAE065D00_057 37.0 68.0 100 125 XTCE080F00_ XTOB070GC1 XTAE080F00_070 45.0 81.0 100 160 XTCE095F00_ XTOB100GC1 XTAE095F00_100 55.0 99.0 100 200 XTCE115G00_ XTOB100GC1 XTAE115G00_100 75.0 134. 100 200 XTCE150G00_ XTOB150GC1 XTAE150G00_150 90.0 161. 100 250 XTCE185L22_ XTOB220LC1 XTAE185L22_220 110. 196. 100 315 XTCE225L22_ XTOB220LC1 XTAE225L22_220 132. 231. 100 400 XTCE250L22_ XTOB250LC1 XTAE250L22_250 160. 279. 100 400 XTCE300M22_ XTOT290C35 XTAE300M22_290 200. 349. 100 500 XTCE400M22_ XTOT400C35 XTAE400M22_400 250. 437. 100 630 XTCE500M22_ XTOT540C35 XTAE500M22_540 � Underscore (_) indicates magnet coil code required. See Table 34-261, Page 34-216. Note: See Page 34-216 for more information on Wye-Delta (Star Delta) applications. Table 34-253. 500V Type 2 Coordination — Contactor and Overload Relay (Motor Starter) with Fused Disconnect P I I Fuses Contactor Overload Relay Assembled Starter e q � � (kW) (A) (kA) Class gG/gL Catalog Number Catalog Number Catalog Number 0.12 0.33 100 2 XTCE007B10_ XTOBP40BC1 XTAE007B10_P40 0.18 0.48 100 2 XTCE007B10_ XTOBP60BC1 XTAE007B10_P60 0.25 0.70 100 2 XTCE007B10_ XTOB001BC1 XTAE007B10_001 0.37 0.90 100 2 XTCE007B10_ XTOB001BC1 XTAE007B10_001 0.55 1.20 100 4 XTCE007B10_ XTOB1P6BC1 XTAE007B10_1P6 0.75 1.50 100 4 XTCE007B10_ XTOB1P6BC1 XTAE007B10_1P6 1.10 2.10 100 6 XTCE007B10_ XTOB2P4BC1 XTAE007B10_2P4 1.50 2.90 100 6 XTCE007B10_ XTOB004BC1 XTAE007B10_004 2.20 4.00 100 10 XTCE007B10_ XTOB006BC1 XTAE007B10_006 3.00 5.30 100 16 XTCE009B10_ XTOB006BC1 XTAE009B10_006 4.00 6.80 100 16 XTCE009B10_ XTOB010BC1 XTAE009B10_010 5.50 9.00 100 20 XTCE012B10_ XTOB010BC1 XTAE012B10_010 7.50 12.1 100 25 XTCE018C10_ XTOB016CC1 XTAE018C10_016 11.0 17.4 100 32 XTCE025C10_ XTOB024CC1 XTAE025C10_024 15.0 23.4 100 50 XTCE040D00_ XTOB024DC1 XTAE040D00_024 18.5 28.9 100 50 XTCE040D00_ XTOB040DC1 XTAE040D00_040 22.0 33.0 100 63 XTCE050D00_ XTOB040DC1 XTAE050D00_040 30.0 44.0 100 80 XTCE065D00_ XTOB057DC1 XTAE065D00_057 37.0 54.0 100 100 XTCE080F00_ XTOB070GC1 XTAE080F00_070 45.0 65.0 100 125 XTCE095F00_ XTOB070GC1 XTAE095F00_070 55.0 79.0 100 160 XTCE115G00_ XTOB100GC1 XTAE115G00_100 75.0 107. 100 200 XTCE185L22_ XTOB125LC1 XTAE185L22_125 90.0 129. 100 200 XTCE185L22_ XTOB125LC1 XTAE185L22_125 110. 157. 100 250 XTCE185L22_ XTOB160LC1 XTAE185L22_160 132. 184. 100 250 XTCE185L22_ XTOB220LC1 XTAE185L22_220 160. 224. 100 315 XTCE225L22_ XTOB250LC1 XTAE225L22_250 � Underscore (_) indicates magnet coil code required. See Table 34-261, Page 34-216. Note: See Page 34-216 for more information on Wye-Delta (Star Delta) applications. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-213 XT IEC Power Control March 2009 Reference Data Table 34-254. 690V Type 2 Coordination — Contactor and Overload Relay (Motor Starter) with Fused Disconnect P I I Fuses Contactor Overload Relay Assembled Starter e q � � (kW) (A) (kA) Class gG/gL Catalog Number Catalog Number Catalog Number 0.12 0.24 100 1 XTCE007B10_ XTOBP40BC1 XTAE007B10_P40 0.18 0.35 100 2 XTCE007B10_ XTOBP40BC1 XTAE007B10_P40 0.25 0.50 100 2 XTCE007B10_ XTOBP60BC1 XTAE007B10_P60 0.37 0.70 100 2 XTCE007B10_ XTOB001BC1 XTAE007B10_001 34 0.55 0.90 100 4 XTCE007B10_ XTOB001BC1 XTAE007B10_001 0.75 1.10 100 4 XTCE007B10_ XTOB1P6BC1 XTAE007B10_1P6 1.10 1.50 100 4 XTCE007B10_ XTOB1P6BC1 XTAE007B10_1P6 1.50 2.10 100 6 XTCE007B10_ XTOB2P4BC1 XTAE007B10_2P4 2.20 2.90 100 10 XTCE007B10_ XTOB004BC1 XTAE007B10_004 3.00 3.80 100 10 XTCE007B10_ XTOB004BC1 XTAE007B10_004 4.00 4.90 100 16 XTCE009B10_ XTOB006BC1 XTAE009B10_006 5.50 6.50 100 16 XTCE012B10_ XTOB010BC1 XTAE012B10_010 7.50 8.80 100 20 XTCE018C10_ XTOB010CC1 XTAE018C10_010 11.0 12.6 100 25 XTCE025C10_ XTOB016CC1 XTAE025C10_016 15.0 17.0 100 32 XTCE032C10_ XTOB024CC1 XTAE032C10_024 18.5 20.9 100 32 XTCE040D00_ XTOB024DC1 XTAE040D00_024 22.0 23.8 100 50 XTCE040D00_ XTOB040DC1 XTAE040D00_040 30.0 32.0 100 63 XTCE065D00_ XTOB040DC1 XTAE065D00_040 37.0 39.0 100 80 XTCE080F00_ XTOB050GC1 XTAE080F00_050 45.0 47.0 100 80 XTCE080F00_ XTOB050GC1 XTAE080F00_050 55.0 58.0 100 100 XTCE080F00_ XTOB070GC1 XTAE080F00_070 75.0 78.0 100 160 XTCE095F00_ XTOB100GC1 XTAE095F00_100 90.0 93.0 100 160 XTCE115G00_ XTOB100GC1 XTAE115G00_100 110. 114. 100 200 XTCE185L22_ XTOB125LC1 XTAE185L22_125 132. 134. 100 250 XTCE185L22_ XTOB160LC1 XTAE185L22_160 160. 162. 100 250 XTCE185L22_ XTOB220LC1 XTAE185L22_220 � Underscore (_) indicates magnet coil code required. See Table 34-261, Page 34-216. Note: See Page 34-216 for more information on Wye-Delta (Star Delta) applications. Table 34-255. 400, 415V Type 2 Coordination — Contactor and Overload Relay (Motor Starter) with Fused Disconnect � P I I Fuses Contactor Overload Relay Assembled Starter e q � � (kW) (A) (kA) Class BS88 Catalog Number Catalog Number Catalog Number 0.12 0.41 80 4 XTCE007B10_ XTOBP60BC1 XTAE007B10_P60 0.18 0.60 80 4 XTCE007B10_ XTOBP60BC1 XTAE007B10_P60 0.25 0.80 80 4 XTCE007B10_ XTOB001BC1 XTAE007B10_001 0.37 1.10 80 6 XTCE007B10_ XTOB1P6BC1 XTAE007B10_1P6 0.55 1.50 80 10 XTCE007B10_ XTOB1P6BC1 XTAE007B10_1P6 0.75 1.90 80 16 XTCE007B10_ XTOB2P4BC1 XTAE007B10_2P4 1.10 2.60 80 16 XTCE007B10_ XTOB004BC1 XTAE007B10_004 1.50 3.60 80 20 XTCE007B10_ XTOB004BC1 XTAE007B10_004 2.20 5.00 80 20 XTCE007B10_ XTOB006BC1 XTAE007B10_006 3.00 6.60 80 20 XTCE007B10_ XTOB010BC1 XTAE007B10_010 4.00 8.50 80 25 XTCE009B10_ XTOB010BC1 XTAE009B10_010 5.50 11.3 80 25 XTCE018C10_ XTOB016CC1 XTAE018C10_016 7.50 16.0 80 25 XTCE018C10_ XTOB016CC1 XTAE018C10_016 11.0 21.7 80 35 & 32M35 XTCE025C10_ XTOB024CC1 XTAE032C10_024 15.0 29.3 80 50 XTCE032C10_ XTOB032CC1 XTAE032C10_032 18.5 36.0 80 63 XTCE040D00_ XTOB040DC1 XTAE040D00_040 22.0 41.0 80 80 XTCE050D00_ XTOB057DC1 XTAE065D00_057 30.0 55.0 80 100 XTCE065D00_ XTOB065DC1 XTAE065D00_065 � GEC/Alstom “Red Spot”. � Underscore (_) indicates magnet coil code required. See Table 34-261, Page 34-216. Note: See Page 34-216 for more information on Wye-Delta (Star-Delta) applications. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-214 XT IEC Power Control March 2009 Reference Data Table 34-256. 400, 415V Type 2 Coordination — Contactor and Overload Relay (Motor Starter) with Circuit Breaker P I I Circuit Contactor Overload Relay Assembled Starter e q � � (kW) (A) (kA) Breaker Catalog Number Catalog Number Catalog Number ���� 0.12 0.41 15 ���� 0.18 0.60 15 ���� 0.25 0.8015 ���� 0.37 1.10 15 ���� 0.55 1.50 15 34 ���� 0.75 1.90 15 ���� 1.10 2.60 15 ���� 1.50 3.60 15 ���� 2.20 5.00 15 ���� 3.00 6.60 15 4.00 8.50 15 HMCPE015E0C XTCE018C10_ XTOB010CC1 XTAE018C10_010 5.50 11.3 15 HMCPE015E0C XTCE018C10_ XTOB016CC1 XTAE018C10_016 ���� 7.50 16.0 15 ���� 11.0 21.7 15 ���� 15.0 29.3 15 ���� 18.5 36.0 50 22.0 41.0 50 HMCPE100R3C XTCE050D00_ XTOB057DC1 XTAE050D00_057 30.0 55.0 50 HMCPE100R3C XTCE065D00_ XTOB065DC1 XTAE065D00_065 37.0 68.0 80 HMCPJ250D5L XTCE080F00_ XTOB070GC1 XTAE080F00_070 45.0 81.0 80 HMCPJ250F5L XTCE095F00_ XTOB100GC1 XTAE095F00_100 55.0 99.0 80 HMCPJ250G5L XTCE115G00_ XTOB125GC1 XTAE115G00_125 75.0 134. 80 HMCPJ250J5L XTCE150G00_ XTOB150GC1 XTAE150G00_150 90.0 161. 80 HMCPJ250W5L XTCE185L22_ XTOB220LC1 XTAE185L22_220 110. 196. 70 HMCPJ250W5L XTCE225L22_ XTOB220LC1 XTAE225L22_220 132. 231. 70 HMCPL600R6G XTCE300M22_ XTOT240C3S XTAE300M22_240 160. 279. 70 HMCPL600X6G XTCE300M22_ XTOT400C3S XTAE300M22_400 200. 349. 70 HMCPL600P6G XTCE400M22_ XTOT400C3S XTAE400M22_400 250. 430. 70 HMCPL600M XCE500M22_ XTOT540C3S XTAE500M22_540 � Underscore (_) indicates magnet coil code required. See Table 34-261, Page 34-216. � Use MMP contactor combination. See Table 34-249, Page 34-210. Note: See Page 34-216 for more information on Wye-Delta (Star Delta) applications. Table 34-257. 525V Type 2 Coordination — Contactor and Overload Relay (Motor Starter) with Circuit Breaker P I I Circuit Contactor Overload Relay Assembled Starter e q � � (kW) (A) (kA) Breaker Catalog Number Catalog Number Catalog Number ���� 0.37 1.02 50 ���� 0.55 1.22 50 ���� 0.75 1.66 50 ���� 1.10 2.22 50 ���� 1.50 3.16 50 ���� 2.20 4.25 50 ���� 3.00 5.60 50 ���� 4.00 7.50 50 ���� 5.50 9.90 50 ���� 7.50 14.1 50 ���� 11.0 19.3 50 ���� 15.0 23.5 50 ���� 18.5 27.2 50 ���� 22.0 37.0 50 ���� 30.0 45.0 50 37.0 54.0 50 HMCP100R3C XTCE080F00_ XTOB070GC1 XTAE080F00_070 45.0 66.0 50 HMCPJ250D5L XTCE080F00_ XTOB070GC1 XTAE080F00_070 55.0 79.0 50 HMCPJ250F5L XTCE115G00_ XTOB100GC1 XTAE115G00_100 75.0 111. 50 HMCPJ250J5L XTCE115G00_ XTOB125GC1 XTAE115G00_125 90.0 130. 50 HMCPJ250K5L XTCE185L00_ XTOB160LC1 XTAE185L00_160 110. 159. 50 HMCPJ250W5L XTCE185L00_ XTOB160LC1 XTAE185L00_160 132. 185. 50 HMCPL600N6G XTCE185L22_ XTOB220LC1 XTAE185L22_220 160. 225. 50 HMCPL600R6G XTCE225L22_ XTOB250LC1 XTAE225L22_250 200. 270. 50 HMCPL600X6G XTCE300M22_ XTOT290C3S XTAE300M22_290 � Underscore (_) indicates magnet coil code required. See Table 34-261, Page 34-216. � Use MMP contactor combination. See Table 34-251, Page 34-211. Note: See Page 34-216 for more information on Wye-Delta (Star Delta) applications. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-215 XT IEC Power Control March 2009 Reference Data Table 34-258. 480V Type 2 Coordination — Contactor and Overload Relay (Motor Starter) with Circuit Breaker P I I Circuit Contactor Overload Relay Assembled Starter e q � � (hp) (A) (kA) Breaker Catalog Number Catalog Number Catalog Number 50.0 65.0 65 HMCPJ250D5L XTCE080F00_ XTOB070GC1 XTAE080F00_070 60.0 77.0 65 HMCPJ250G5L XTCE080F00_ XTOB100GC1 XTAE080F00_100 75.0 96.0 25 HMCPJ250J5L XTCE115G00_ XTOB125GC1 XTAE115G00_125 100. 124. 50 HMCPJ250K5L XTCE185L22_ XTOB160LC1 XTAE185L22_160 34 125. 156. 50 HMCPJ250W5L XTCE185L22_ XTOB160LC1 XTAE185L22_160 150. 180. 25 HMCPL600N6G XTCE225L22_ XTOB220LC1 XTAE225L22_220 200. 240. 50 HMCPL600N XTCE300M22_ XTOB240C3S XTAE300M22_240 250. 290. 50 HMCPL600R XTCE300M22_ XTOB290C3S XTAE300M22_290 300. 361. 50 HMCPL600Y XTCE400M22_ XTOB400C3S XTAE400M22_400 350. 414. 50 HMCPL600M XTCE500M22_ XTOB540C3S XTAE500M22_540 � Underscore (_) indicates magnet coil code required. See Table 34-261, Page 34-216. � Table 34-259. 400, 415V Type 2 Coordination — Contactor with Circuit Breaker P I I Circuit Contactor e q � (kW) (A) (kA) Breaker — MCP Catalog Number 1.50 3.60 50 HMCPE015E0C XTCE018C10_ 2.20 5.00 50 HMCPE015E0C XTCE018C10_ 3.00 6.60 50 HMCPE015E0C XTCE018C10_ 4.00 8.50 50 HMCPE015E0C XTCE018C10_ 5.50 11.3 50 HMCPE015E0C XTCE018C10_ 7.50 16.0 50 HMCPE015E0C XTCE018C10_ 11.0 21.7 50 HMCPE100R3C XTCE040D00_ 15.0 29.3 50 HMCPE100R3C XTCE040D00_ 18.5 36.0 50 HMCPE100R3C XTCE040D00_ 22.0 41.0 50 HMCPE100R3C XTCE050D00_ 30.0 55.0 50 HMCPE100R3C XTCE065D00_ 37.0 68.0 80 HMCPJ250D5L XTCE080F00_ 45.0 81.0 80 HMCPJ250F5L XTCE095F00_ 55.0 99.0 80 HMCPJ250G5L XTCE115G00_ 75.0 134. 80 HMCPJ250J5L XTCE150G00_ 90.0 161. 80 HMCPJ250W5L XTCE185L22_ 110. 196. 80 HMCPJ250W5L XTCE225L22_ 132. 231. 70 HMCPL600R XTCE300M22_ 160. 279. 70 HMCPL600X XTCE300M22_ 200. 350. 70 HMCPL600P XTCE400M22_ 250. 430. 70 HMCPL600M XTCE500M22_ � For use with magnetic sensing means to monitor motor current. � Underscore (_) indicates magnet coil code required. See Table 34-261, Page 34-216. � Table 34-260. 480V Type 2 Coordination — Contactor with Circuit Breaker P I I Circuit Contactor e q � (hp) (A) (kA) Breaker — MCP Catalog Number 50.0 65.0 65 HMCPJ250G5L XTCE080F00_ 60.0 77.0 65 HMCPJ250G5L XTCE080F00_ 150. 180. 50 HMCPL600N XTCE300M00_ 200. 240. 50 HMCPL600N XTCE300M22__ 250. 300. 50 HMCPL600R XTCE300M22_ 300. 361. 50 HMCPL600Y XTCE400M00_ 350. 414. 50 HMCPL600M XTCE500M00_ � For use with magnetic sensing means to monitor motor current. � Underscore (_) indicates magnet coil code required. See Table 34-261, Page 34-216. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-216 XT IEC Power Control March 2009 Reference Data Wye-Delta (Star-Delta) Applications If Type 2 Coordination is required when using Wye-Delta starters, the full voltage (direct on-line) test data that is included in this document is valid. To ensure proper protection, the K1M (Main), K3M (Star) and K5M (Delta) contactors must all be the same size (amperage). For Wye-Delta starter kits, please see Page 34-44. Table 34-261. Magnet Coil Suffix Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code Frame A – B Frame C – F Frame G 34 110V 50 Hz, 120V 60 Hz A 110V 50 Hz, 120V 60 Hz A 100 – 120V 50/60 Hz A 220V 50 Hz, 240V 60 Hz B 220V 50 Hz, 240V 60 Hz B 190 – 240V 50/60 Hz B 230V 50 Hz F 230V 50 Hz F 24V 50/60 Hz T � 24V 50/60 Hz T 24V 50/60 Hz T 24 – 27V DC TD � � 24V DC TD 24 – 27V DC TD 480 – 500V 50/60 Hz C 415V 50 Hz, 480V 60 Hz C 415V 50 Hz, 480V 60 Hz C 380 – 440V 50/60 Hz L 550V 50 Hz, 600V 60 Hz D 550V 50 Hz, 600V 60 Hz D 42 – 48V 50/60 Hz W � 208V 60 Hz E 208V 60 Hz E 110 – 130V DC AD � 190V 50 Hz, 220V 60 Hz G 190V 50 Hz, 220V 60 Hz G 200 – 240V DC BD � 240V 50 Hz, 277V 60 Hz H 240V 50 Hz, 277V 60 Hz H 48 – 60V DC WD 380V 50 Hz, 440V 60 Hz L 380V 50 Hz, 440V 60 Hz L Frame L – M 400V 50 Hz N 400V 50 Hz N 110 – 250V 40 – 60 Hz/DC A 380V 60 Hz P 380V 60 Hz P 250 – 500V 40 – 60 Hz/DC C � 12V 50/60 Hz R 12V 50/60 Hz R 48 – 110V 40 – 60 Hz/DC Y � 24V 50 Hz U 24V 50 Hz U 24 – 48V DC TD 42V 50 Hz, 48V 60 Hz W 42V 50 Hz, 48V 60 Hz W 48V 50 Hz Y 48V 50 Hz Y � � 120V DC AD 110 – 130V DC AD � � 220V DC BD 200 – 240V DC BD � � 12V DC RD 12 – 14V DC RD � � 48V DC WD 48 – 60V DC WD � With DC operation: Integrated diode-resistor combination, coil rating 2.6W. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-217 XT IEC Power Control March 2009 Reference Data Approvals for World Markets Belgium Canada Comité Electro- Canadian Standards technique Belge Association Overview Belgisch Elektro- (CSA) The XT line of products is approved technisch Comité for use throughout the world, includ- (CEBEC) ing the USA and Canada. As such, they Recently introduced is the mandatory can be used without restriction as approval of electrical products for: 34 devices for world markets. Denmark ■ Slovakia Danmarks Elektriske The majority of countries permit the ■ Poland Materielkontrol import of devices on the manufac- ■ South Africa (DEMKO) turer’s undertaking that they have ■ China been constructed in accordance with the pertinent specifications. In the USA ■ Russia and Canada, however, there is a legal Finland ■ Turkey obligation to obtain official approval. (FIMKO) ■ Argentina In these countries, devices and enclo- sures — sometimes even complete Marking is partly mandatory for these control systems — are tested and countries. The IEC rating data is approved by independent bodies. accepted as in other European France countries. In Europe, there also used to be a legal Union Technique obligation to obtain official approval de l’Electricité Approval is not mandatory in the for low-voltage switchgear and con- (UTE) Czech Republic and Hungary. The trolgear. For industrial control gear, manufacturer’s declaration of confor- this legal obligation has now been mity is sufficient here. abolished, provided the devices have Netherlands Romania requires that components been manufactured and tested Naamloze Vennootschap that are to be used in public buildings in accordance with harmonized tot Keuring van must be approved by the Romanian European standards (such as IEC/EN Electrotechnische test authority ICECON. 60947). There is then no longer a Materialien requirement for them to carry their (KEMA) Russia country’s own approval mark. Devices for Russia must bear the appropriate Since January 1997, all devices must Norway conform to the European Low-Voltage marking. Norges Elektriske Directive and, where intended for sale Russia Materiellkontrol within the European Union, must carry Goststandart (NEMKO) the CE mark. (GOST-R) Europe Sweden Conformité Européen South Africa Svenska (CE) ZA Elektriska Materiel- SABS Kontrollanstalten This mark denotes that the device (SEMKO) carrying it conforms to all relevant requirements and specifications. The Argentina mandatory application of this mark Switzerland therefore enables the unrestricted use Schweizerischer of marked devices within the European Elektrotechischer economic area. Verein (SEV) Since January 1996, all devices sold Selection of Devices within the European union must com- ”Selection appropriate for export” Devices the USA and Canada have UL ply with the Electromagnetic Compati- does not mean merely meeting the and CSA approval. bility (EMC) Directive. XT has passed requisite approvals and conformity to the required tests to these Directives, USA relevant specifications. The meaning and the devices carry the CE mark, of the term goes a great deal further Underwriters demonstrating compliance with the Laboratories by even including that equipment and EMC Directive. Because devices Listing installations must be designed to a (UL) bearing the CE mark comply with the concept with export in mind. harmonized standards, approval and Recognition the associated marking is no longer required in the following countries: CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-218 XT IEC Power Control March 2009 Reference Data The following are important criteria for ❑ Advantage: the right fuse in these circum- selecting switchgear suitable for export: stances. These problems do – Total insulation is the best pos- not arise where a circuit- sible protective measure from ■ For motor-protective circuit-breakers breaker is used. the user’s point of view, avoid- Use inherently short-circuit proof ing reliance on the possibly ■ For main switches and safety switches capable of controlling the doubtful skills of unknown switches highest prospective fault levels at installation personnel. Further- Use devices with positive contact the point of installation without the more, protective measures separation and clear switch need for back-up protection. 34 based on earthing are often position indication. ❑ Advantage: extremely difficult, if not ❑ Advantage: – No restrictions whatsoever for impossible (in the Middle East, – The mechanical coupling of the installation for example, due to the dryness actuating element with the of the ground). – Complete independence from contacts ensues that the OFF the on-site protective system – Insulated enclosures com- position is indicated only when pletely eliminate the need for – No problems getting spare all main contacts are separated any additional protection parts by the prescribed distance, and against corrosion. The trans- only in this position can the ■ For circuit-breakers parent covers contribute switch be padlocked. This Use types with visible contacts, significantly to the correct ensures safety when carrying quick-make and quick-break operation of a system, because out maintenance and repair operation as standard. Use current- switchgear operation can be work on the installation or limiting circuit-breakers for high monitored even with the doors machinery. short-circuit levels. Selective or covers closed, thus virtually switches are recommended for the eliminating the possibility of Test Authorities selective graduation of networks. these being left open through ❑ Advantage: USA carelessness. The transparent USA – Independence from local cover is an important contribu- UL accident prevention regulations tion to safety, especially where requiring visible contacts, and exports to areas of uncertain safety faults caused by inexpe- skills are concerned. Canada CDN rienced operating personnel. ■ For overcurrent protective devices CSA – The effects of short-circuits are Always use circuit-breakers and kept to a minimum. motor-protective circuit-breakers. Romania Avoid fuses as far as possible. – Fuseless installations offer RO ❑ Advantage: greater safety and reliability in ICECON plant operation. In the event of – The operational reliability of a Russia a fault, only the faulty section system is especially important RUS of the system is isolated. for export contracts. Circuit- GOST-R breakers and motor-protective ■ For contactors South Africa circuit-breakers provide this Use contactors whose entire range ZA reliability in full measure since provides consistently reliable opera- SABS they can be immediately tion in the event of voltage drops Slovakia reclosed once a fault has been (consistently down to 80% U n cleared, they disconnect all SK should be aimed for) and whose SKTC poles, they have ideal protec- contact system will not assume tion through high tripping an indeterminate position either accuracy and they can be used on closing or on opening in such Poland for selective operation. conditions. PL Because they have no fuses or BBJ-SEP ❑ Advantage: other consumables, they also – During the electrification work Turkey greatly reduce the problem of in areas such as Africa and the TR obtaining replacement parts. Middle East, an insufficient TSE The advantages of fuseless voltage stability is — at least design for export are especially China for a certain time — likely in evident in this case. No compli- PRC many applications (for example cated investigation is needed to CCC due to long spur lines or small find out which fusing system is local generators). The use of used in the respective location Ukraine devices that fulfill the above UA and which specifications have requirements will eliminate one to be followed to select the cor- Ukrain-GOST of the main failure causes rect fuses. Often several differ- related to contactors. ent fuse systems with widely ■ For enclosures varying characteristics are used Use insulated enclosures with side-by-side in the same coun- transparent covers (i.e. “totally try. For the uninitiated, it may insulated” enclosures). be almost impossible to find For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-219 XT IEC Power Control March 2009 Reference Data Shipping Classifications Approvals for North America In the USA, the legally established In addition to the normal UL and CSA Germany OSHA (Occupational Safety and Health approvals, the trade regulations origi- Germanischer Lloyd Act) and the NEC (National Electrical nating from the NAFTA agreements (GL) Code) require the use of approved allow the application for a joint UL and devices and systems. CSA approval. The devices then carry Great Britain a logo that is recognized in both Lloyd‘s Register of In Canada, all electrical apparatus countries. 34 Shipping (LR) must comply with the CEC (Canadian Electrical Code), requires that all Some local inspectors and end users equipment and installations have CSA still refuse to accept the joint listing. France approval. Bureau Veritas (BV) Table 34-262. Approvals for North America Type of Approval Approval Mark Russia The device is UL- and CSA-approved as discrete device. Russian Maritime Register of Shipping (RS) Italy The device is CSA-approved as discrete device. Registro Italiano Navale (RINA) The device is UL-approved as discrete device. Norway Det Norske Veritas (DNV) The device contains UL-approved components; its approval Poland conditions must be maintained in use (UL Recognized). The Polski Rejestr Statkow device is CSA-approved as discrete device. (PRS) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-220 XT IEC Power Control March 2009 Reference Data Table 34-263. Used in Technical Data & Code Descriptions IEC Utilization Categories Formula I Response value of short-time delayed rmv (See also IEC/EN 60947-1; Code Descriptions short-circuit release 2.1.18/IEV 441-17-19) DF Duty factory I Response value of short-time delayed sd short-circuit release A combination of specified require- I Response value of earth-fault release Δn ments relating to the condition in I Response value of earth-fault release T I Rated short-circuit making capacity cm which the switching device or fuse I Response value of earth-fault release g I Rated short-circuit breaking capacity 34 fulfills its purpose and selected to cn I Conventional free air thermal current th represent a characteristic group of I Rated service short-circuit breaking cs capacity real-life applications. The specified I Conventional thermal current of the enclosed devices requirements may, for example, relate I Rated ultimate short-circuit breaking cu to the values of making and breaking capacity I Rated uninterrupted current u capacity and other characteristic val- I Rated short-time withstand current S Transformer rating cw NT ues, data concerning associated cir- I Rated operational current t Time delay of overload release e r cuits and the applicable conditions response I Transformer initial short-circuit AC cur- of use and operational behavior. k rent t Time delay of earth-fault release T response I Load monitoring response value L t Time delay of earth-fault release g I Rated current n response I Transformer rated current NT t Time delay of short-circuit release v response I Rated peak withstand current PK U Rated actuating voltage I Rated conditional short-circuit current c q U Rated operational voltage I Overcurrent release set value e r U Rated insulation voltage I Response value of non-delayed short- i rm circuit release U Rated impulse withstand voltage imp I Response value of non-delayed short- i U Transformer short-circuit voltage k circuit release U Rated control voltage s I Response value of fixed, non-delayed rmf short-circuit release Annex A (informative) � Table 34-264. Examples of Utilization Categories for Low-Voltage Switchgear and Controlgear Category Typical Applications Relevant IEC Product Standard Nature of Current — AC AC-1 Non-inductive or slightly inductive loads, resistance furnaces 60947-4-1 AC-2 Slip-ring motors: starting, switching off 60947-4-1 AC-3 Squirrel-cage motors: starting, switching off motors during running 60947-4-1 � � AC-4 Squirrel-cage motors: starting, plugging , inching 60947-4-1 AC-5a Switching of electric discharge lamp controls 60947-4-1 AC-5b Switching of incandescent lamps 60947-4-1 AC-6a Switching of transformers 60947-4-1 AC-6b Switching of capacitor banks 60947-4-1 AC-7a Slightly inductive loads for household appliances and similar applications 61095 AC-7b Motor-loads for household applications 61095 AC-8a Hermetic refrigerant compressor motor control with manual resetting of overload releases 60947-4-1 AC-8b Hermetic refrigerant compressor motor control with automatic resetting of overload releases 60947-4-1 AC-12 Control of resistive loads and solid-state loads with isolation by optocouplers 60947-5-1 AC-12 Control of resistive loads and solid-state loads with optical isolation 60947-5-2 AC-13 Control of solid-state loads with transformer isolation 60947-5-1 AC-14 Control of small electromagnetic loads 60947-5-1 AC-15 Control of AC electromagnetic loads 60947-5-1 AC-20 Connecting and disconnecting under no-load conditions 60947-3 AC-21 Switching of resistive loads, including moderate overloads 60947-3 AC-22 Switching of mixed resistive and inductive loads, including moderate overloads 60947-3 AC-23 Switching of motor loads or other highly inductive loads 60947-3 � 60947-1 © IEC: 2004. � By plugging is understood stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running. � By inching (jogging) is understood energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-221 XT IEC Power Control March 2009 Reference Data Annex A (informative) � Table 34-264. Examples of Utilization Categories for Low-Voltage Switchgear and Controlgear (Continued) Category Typical Applications Relevant IEC Product Standard Nature of Current — AC (Continued) AC-31 Non inductive or slightly inductive loads 60947-6-1 AC-33 Motor loads or mixed loads including motors, resistive loads and up to 30% incandescent lamp loads 60947-6-1 AC-35 Electric discharge lamp loads 60947-6-1 34 AC-36 Incandescent lamp loads 60947-6-1 AC-40 Distribution circuits comprising mixed resistive and reactive loads having a resultant inductive 60947-6-2 reactance AC-41 Non-inductive or slightly inductive loads, resistance furnaces 60947-6-2 AC-42 Slip-ring motors: starting, switching off 60947-6-2 AC-43 Squirrel-cage motors: starting, switching off motors during running 60947-6-2 � � AC-44 Squirrel-cage motors: starting, plugging , inching 60947-6-2 AC-45a Switching of electric discharge lamp controls 60947-6-2 AC-45b Switching of incandescent lamps 60947-6-2 AC-51 Non-inductive or slightly inductive loads, resistance furnaces 60947-4-3 AC-52a Control of slip ring motor stators: 8 h duty with on-load currents for start, acceleration, run 60947-4-2 AC-52b Control of slip ring motor stators: intermittent duty 60947-4-2 AC-53a Control of squirrel-cage motors: 8 h duty with on-load currents for start, acceleration, run 60947-4-2 AC-53b Control of squirrel-cage motors: intermittent duty 60947-4-2 AC-55a Switching of electric discharge lamp controls 60947-4-3 AC-55b Switching of incandescent lamps 60947-4-3 AC-56a Switching of transformers 60947-4-3 AC-56b Switching of capacitor banks 60947-4-3 AC-58a Control of hermetic refrigerant compressor motors with automatic resetting of overload releases: 60947-4-2 8 h duty with on-load currents for start, acceleration, run AC-58b Control of hermetic refrigerant compressor motors with automatic resetting of overload releases: 60947-4-2 intermittent duty AC-140 Control of small electromagnetic loads with holding (closed) current ≤ 0,2 A, e.g. contactor relays 60947-5-2 Nature of Current — AC and DC A Protection of circuits, with no rated short-time withstand current 60947-2 B Protection of circuits, with a rated short-time withstand current 60947-2 Nature of Current — DC DC-1 Non-inductive or slightly inductive loads, resistance furnaces 60947-4-1 � � DC-3 Shunt-motors: starting, plugging , inching , Dynamic breaking of motors 60947-4-1 � � DC-5 Series-motors: starting, plugging , inching , Dynamic breaking of motors 60947-4-1 DC-6 Switching of incandescent lamps 60947-4-1 DC-12 Control of resistive loads and solid-state loads with isolation by optocouplers 60947-5-1 DC-12 Control of resistive loads and solid-state loads with optical isolation 60947-5-2 DC-13 Control of electromagnets 60947-5-1 DC-13 Control of electromagnets 60947-5-2 DC-14 Control of electromagnetic loads having economy resistors in circuit 60947-5-1 DC-20 Connecting and disconnecting under no-load conditions 60947-3 DC-21 Switching of resistive loads, including moderate overloads 60947-3 DC-22 Switching of mixed resistive and inductive loads, including moderate overloads (e.g. shunt motors) 60947-3 DC-23 Switching of motor loads or other highly inductive loads (e.g. series motors) 60947-3 DC-31 Resistive loads 60947-6-1 DC-33 Motor loads or mixed loads including motors 60947-6-1 DC-36 Incandescent lamp loads 60947-6-1 DC-40 Distribution circuits comprising mixed resistive and reactive loads having a resultant inductive 60947-6-2 reactance DC-41 Non-inductive or slightly inductive loads, resistance furnaces 60947-6-2 � � DC-43 Shunt-motors: starting, plugging , inching , Dynamic breaking of DC 60947-6-2 � � DC-45 Series-motors: starting, plugging , inching , Dynamic breaking of DC 60947-6-2 DC-46 Switching of incandescent lamps 60947-6-2 � 60947-1 © IEC: 2004. � By plugging is understood stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running. � By inching (jogging) is understood energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-222 Reference Data March 2009 Caution — These average ratings could be high or low for Motor Ratings Data a specific motor and therefore heater coil selection on this basis always involves risk. For fully reliable motor protection, Ampere Rating of AC and DC Motors select heater coils on the basis of full load current rating as Ampere ratings of motors vary somewhat, depending upon shown on the motor nameplate. the type of motor. The values given below are for drip-proof, Class B insulated (T Frame) where available, 1.15 service factor, NEMA Design B motors. These values represent an 34 average full load motor current which was calculated from the motor performance data published by several motor manufacturers. In the case of high torque squirrel cage motors, the ampere ratings will be at least 10% greater than the values given below. Ampere Ratings of Three-Phase, 60 Hz, AC Induction Motor hp Syn. Current in Amperes hp Syn. Current in Amperes Speed Speed � � 200V 230V 380V 460V 575V 2200V 200V 230V 380V 460V 575V 2200V RPM RPM 1/4 1800 1.09 .95 .55 .48 .38 — 25 3600 69.9 60.8 36.8 30.4 24.3 — 1200 1.61 1.40 .81 .70 .56 — 1800 74.5 64.8 39.2 32.4 25.9 — 900 1.84 1.60 .93 .80 .64 — 1200 75.4 65.6 39.6 32.8 26.2 — 900 77.4 67.3 40.7 33.7 27.0 — 1/3 1800 1.37 1.19 .69 .60 .48 — 1200 1.83 1.59 .92 .80 .64 — 30 3600 84.8 73.7 44.4 36.8 29.4 — 900 2.07 1.80 1.04 .90 .72 — 1800 86.9 75.6 45.7 37.8 30.2 — 1200 90.6 78.8 47.6 39.4 31.5 — 1/2 1800 1.98 1.72 .99 .86 .69 — 900 94.1 81.8 49.5 40.9 32.7 — 1200 2.47 2.15 1.24 1.08 .86 — 900 2.74 2.38 1.38 1.19 .95 — 40 3600 111 96.4 58.2 48.2 38.5 — 1800 116 101 61.0 50.4 40.3 — 3/4 1800 2.83 2.46 1.42 1.23 .98 — 1200 117 102 61.2 50.6 40.4 — 1200 3.36 2.92 1.69 1.46 1.17 — 900 121 105 63.2 52.2 41.7 — 900 3.75 3.26 1.88 1.63 1.30 — 50 3600 138 120 72.9 60.1 48.2 — 1 3600 3.22 2.80 1.70 1.40 1.12 — 1800 143 124 75.2 62.2 49.7 — 1800 4.09 3.56 2.06 1.78 1.42 — 1200 145 126 76.2 63.0 50.4 — 1200 4.32 3.76 2.28 1.88 1.50 — 900 150 130 78.5 65.0 52.0 — 900 4.95 4.30 2.60 2.15 1.72 — 60 3600 164 143 86.8 71.7 57.3 — 1-1/2 3600 5.01 4.36 2.64 2.18 1.74 — 1800 171 140 90.0 74.5 59.4 — 1800 5.59 4.86 2.94 2.43 1.94 — 1200 173 150 91.0 75.0 60.0 — 1200 6.07 5.28 3.20 2.64 2.11 — 900 177 154 93.1 77.0 61.5 — 900 6.44 5.60 3.39 2.80 2.24 — 75 3600 206 179 108 89.6 71.7 — 2 3600 6.44 5.60 3.39 2.80 2.24 — 1800 210 183 111 91.6 73.2 — 1800 7.36 6.40 3.87 3.20 2.56 — 1200 212 184 112 92.0 73.5 — 1200 7.87 6.84 4.14 3.42 2.74 — 900 222 193 117 96.5 77.5 — 900 9.09 7.90 4.77 3.95 3.16 — 100 3600 266 231 140 115 92.2 — 3 3600 9.59 8.34 5.02 4.17 3.34 — 1800 271 236 144 118 94.8 23.6 1800 10.8 9.40 5.70 4.70 3.76 — 1200 275 239 145 120 95.6 24.2 1200 11.7 10.2 6.20 5.12 4.10 — 900 290 252 153 126 101 24.8 900 13.1 11.4 6.90 5.70 4.55 — 125 3600 — 292 176 146 116 — 5 3600 15.5 13.5 8.20 6.76 5.41 — 1800 — 293 177 147 117 29.2 1800 16.6 14.4 8.74 7.21 5.78 — 1200 — 298 180 149 119 29.9 1200 18.2 15.8 9.59 7.91 6.32 — 900 — 305 186 153 122 30.9 900 18.3 15.9 9.60 7.92 6.33 — 150 3600 — 343 208 171 137 — 7-1/2 3600 22.4 19.5 11.8 9.79 7.81 — 1800 — 348 210 174 139 34.8 1800 24.7 21.5 13.0 10.7 8.55 — 1200 — 350 210 174 139 35.5 1200 25.1 21.8 13.2 10.9 8.70 — 900 — 365 211 183 146 37.0 900 26.5 23.0 13.9 11.5 9.19 — 200 3600 — 452 257 226 181 — 10 3600 29.2 25.4 15.4 12.7 10.1 — 1800 — 458 265 229 184 46.7 1800 30.8 26.8 16.3 13.4 10.7 — 1200 — 460 266 230 184 47.0 1200 32.2 28.0 16.9 14.0 11.2 — 900 — 482 279 241 193 49.4 900 35.1 30.5 18.5 15.2 12.2 — 250 3600 — 559 338 279 223 — 15 3600 41.9 36.4 22.0 18.2 14.5 — 1800 — 568 343 284 227 57.5 1800 45.1 39.2 23.7 19.6 15.7 — 1200 — 573 345 287 229 58.5 1200 47.6 41.4 25.0 20.7 16.5 — 900 — 600 347 300 240 60.5 900 51.2 44.5 26.9 22.2 17.8 — 300 1800 — 678 392 339 271 69.0 20 3600 58.0 50.4 30.5 25.2 20.1 — 1200 — 684 395 342 274 70.0 1800 58.9 51.2 31.0 25.6 20.5 — 1200 60.7 52.8 31.9 26.4 21.1 — 400 1800 — 896 518 448 358 91.8 900 63.1 54.9 33.2 27.4 21.9 — 500 1800 — 1110 642 555 444 116 � 380V 50 Hz. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-223 XT IEC Power Control March 2009 Reference Data Single-Phase AC Motors DC Motors hp Armature Voltage Ampere � Rating Capacity of Table 430.248. Full-Load Currents in Amperes, Table 430.247. Full-Load Current in Amperes, Fuses for Motors Single-Phase Alternating-Current Motors Direct-Current Motors Recommended The following values of full-load The following values of full-load cur- Values currents are for motors running at rents are for motors running at base 120V 240V 120V 240V usual speeds and motors with normal speed. 1/4 3.1 1.6 5 3 torque characteristics. Motors built for Note: These are average direct-current 1/3 4.1 2.0 5 3 especially low speeds or high torques 34 quantities. 1/2 5.4 2.7 7 3 may have higher full-load currents and 3/4 7.6 3.8 10 5 multispeed motors will have full-load 1 9.5 4.7 15 7 current varying with speed, in which 1-1/2 13.2 6.6 20 10 case the nameplate current ratings 2 17 8.5 25 12 shall be used. 3 25 12.2 30 15 5 40 20 50 25 The voltages listed are rated motor 7-1/2 58 29 80 40 voltages. The currents listed shall be 10 76 38 100 50 permitted for system voltage ranges of 15 — 55 — 75 20 — 72 — 100 110 to 120 and 220 to 240V. 25 — 89 — 125 30 — 106 — 150 hp 115V 200V 208V 230V 40 — 140 — 200 1/6 4.4 2.5 2.4 2.2 50 — 173 — 250 1/4 5.8 3.3 3.2 2.9 60 — 206 — 275 1/3 7.2 4.1 4.0 3.6 75 — 255 — 350 1/2 9.8 5.6 5.4 4.9 100 — 341 — 500 3/4 13.8 7.9 7.6 6.9 125 — 425 — 600 1 16 9.2 8.8 8 150 — 506 — — 1-1/2 20 11.5 11 10 200 — 675 — — 2 24 13.8 13.2 12 � These are average direct-current quantities. 3 34 19.6 18.7 17 5 56 32.2 30.8 28 7-1/2 80 46 44 40 10 100 57.5 55 50 Table 430.250. Full-Load Current Three-Phase Alternating-Current Motors Three-Phase AC Motors hp Induction Type Squirrel-Cage and Synchronous Type Unity The following values of full-load � Wound-Rotor Amperes Power Factor Amperes currents are typical for motors running 115V 200V 208V 230V 460V 575V 2300V 230V 460V 575V 2300V at speeds usual for belted motors and motors with normal torque 1/2 4.4 2.5 2.4 2.2 1.1 .9 — — — — — characteristics. 3/4 6.4 3.7 3.5 3.2 1.6 1.3 — — — — — 1 8.4 4.8 4.6 4.2 2.1 1.7 — — — — — Motors built for low speeds (1,200 RPM 1-1/2 12.0 6.9 6.6 6.0 3.0 2.4 — — — — — or less) or high torques may require 2 13.6 7.8 7.5 6.8 3.4 2.7 — — — — — more running current and multispeed 3 — 11.0 10.6 9.6 4.8 3.9 — — — — — motors will have full-load current 5 — 17.5 16.7 15.2 7.6 6.1 — — — — — varying with speed. In these cases 7-1/2 — 25.3 24.2 22 11 9 — — — — — the nameplate current rating shall 10 — 32.2 30.8 28 14 11 — — — — — be used. 15 — 48.3 46.2 42 21 17 — — — — — 20 — 62.1 59.4 54 27 22 — — — — — The voltages listed are rated motor 25 — 78.2 74.8 68 34 27 — 53 26 21 — voltages. The currents listed shall be 30 — 92 88 80 40 32 — 63 32 26 — permitted for system voltage ranges of 40 — 120 114 104 52 41 — 83 41 33 — 110 to 120, 220 to 240, 440 to 480 and 50 — 150 143 130 65 52 — 104 52 42 — 550 to 600V. 60 — 177 169 154 77 62 16 123 61 49 12 75 — 221 211 192 96 77 20 155 78 62 15 100 — 285 273 248 124 99 26 202 101 81 20 125 — 359 343 312 156 125 31 253 126 101 25 150 — 414 396 360 180 144 37 302 151 121 30 200 — 552 528 480 240 192 49 400 201 161 40 250 — — — — 302 242 60 — — — — 300 — — — — 361 289 72 — — — — 350 — — — — 414 336 83 — — — — 400 — — — — 477 382 95 — — — — 450 — — — — 515 412 103 — — — — 500 — — — — 590 472 118 — — — — � For 90 and 80 percent power factor, the above figures shall be multiplied by 1.1 and 1.25 respectively. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-224 XT IEC Power Control March 2009 Reference Data � Table 310.15 (B)(z)(a). Adjustment Factor for Ampacities of Insulated Conductors (Based on 2005 NEC ) More Than Three Current-Carrying Conduc- Table 310.16. Allowable Ampacities of Insulated Conductors Rated 0 – 2000V, 60° – 90°C tors in Raceway or Cable (140° – 194°F), Not More Than Three Current-Carrying Conductors in Raceway or Cable or Earth (Directly Buried), Based on Ambient Temperature of 30°C (86°F) Where the number of current-carrying conductors in a raceway or cable Size Temperature Rating of Conductor. See NEC Table 310-13. Size exceeds three, the allowable ampaci- AWG 60°C 75°C 90°C 60°C 75°C 90°C AWG kcmil (140°F) (167°F) (194°F) (140°F) (167°F) (194°F) kcmil ties shall be reduced as shown in the following table: 34 Types Types Types Types Types Types � � � � TW†, UF FEPW , TBS, SA, TW , RH , TBS, � � � � RH , SIS, FEP , UF RHW , SA, SIS, Number of Current- Percent of Values in � � � � RHW , FEPB , THHW , THHN , Carrying Conductors Tables as Adjusted for � � � � THHW , MI, RHH , THW , THHW , Ambient Temperature � � THW , RHW-2, THWN , THW-2, if Necessary � � � THWN , THHN , XHHW , THWN-2, � � � � XHHW , THHW , USE RHH , 4 – 6 80 � � USE , THW-2 , RHW-2, 7 – 9 70 � � ZW THWN-2 , USE-2, 10 – 20 50 USE-2, XHH, 21 – 30 45 XHH, XHHW, 31 – 40 40 � XHHW , XHHW-2, 41 and above 35 XHHW-2, ZW-2 ZW-2 Where single conductors or multicon- Copper Aluminum or Copper-Clad ductor cables are stacked or bundled Aluminum longer than 24 in. (610 mm) without 18 — — 14 — — — — maintaining spacing and are not 16 — — 18 — — — — installed in raceways, the allowable 14 20✝ 20✝ 25† — — — — ampacity of each conductor shall be 12 25✝ 25✝ 30† 20† 20† 25† 12 reduced as shown in the above table. 10 30 35✝ 40† 25 30† 35† 10 8 40 50 55 30 40 45 8 6 55 65 75 40 50 60 6 4 70 85 95 55 65 75 4 3 85 100 110 65 75 85 3 2 95 115 130 75 90 100 2 1 110 130 150 85 100 115 1 1/0 125 150 170 100 120 135 1/0 2/0 145 175 195 115 135 150 2/0 3/0 165 200 225 130 155 175 3/0 4/0 195 230 260 150 180 205 4/0 250 215 255 290 170 205 230 250 285 320 190 230 255 300 300 240 350 260 310 350 210 250 280 350 400 280 335 380 225 270 305 400 500 320 380 430 260 310 350 500 600 355 420 475 285 340 385 600 700 385 460 520 310 375 420 700 750 400 475 535 320 385 435 750 800 410 490 555 330 395 450 800 900 435 520 585 355 425 480 900 1000 455 545 615 375 445 500 1000 1250 495 590 665 405 485 545 1250 1500 520 625 705 435 520 585 1500 1750 545 650 735 455 545 615 1750 2000 560 665 750 470 560 630 2000 Correction Factors Ambient For Ambient Temperatures Other Than 30°C (86°F), Multiply the Allowable Ambient Temp. °C Ampacities Shown Above by the Appropriate Factor Shown Below Temp. °F 21 – 25 1.08 1.05 1.04 1.08 1.05 1.04 70 – 77 26 – 30 1.00 1.00 1.00 1.00 1.00 1.00 78 – 86 31 – 35 .91 .94 .96 .91 .94 .96 87 – 95 36 – 40 .82 .88 .91 .82 .88 .91 96 – 104 41 – 45 .71 .82 .87 .71 .82 .87 105 – 113 46 – 50 .58 .75 .82 .58 .75 .82 114 – 122 51 – 55 .41 .67 .76 .41 .67 .76 123 – 131 56 – 60 — .58 .71 — .58 .71 132 – 140 61 – 70 — .33 .58 — .33 .58 141 – 158 71 – 80 — — .41 — — .41 159 – 176 � Reprinted by permission from NFPA 70-2005. National Electrical Code®, Copyright© 2005. National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. � Unless otherwise specifically permitted elsewhere in this Code, the overcurrent protection for conductor types marked with an obelisk (†) shall not exceed 15A for No. 14, 20A for No. 12 and 30A for No. 10 copper; or 15A for No. 12 and 25A for No. 10 aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-225 XT IEC Power Control March 2009 Reference Data � Ampacities of Insulated Conductors (Based on 2005 NEC ) — Continued Table 310.18. Allowable Ampacities of Three Single Insulated Conductors Rated 0 – 2000V, 150° – 250°C (302° – 482°F), in Raceway or Cable Based on Ambient Air Temperature of 40°C (104°F) Size Temperature Rating of Conductor. See NEC Table 310-13. Size AWG 150°C 200°C 250°C 150°C AWG kcmil (302°F) (392°F) (482°F) (302°F) kcmil 34 Type Types Types Type Z FEP, FEPB, PFA PFAH, TFE Z Copper Nickel or Aluminum or Nickel-Coated Copper-Clad Copper Aluminum 14 34 36 39 — 14 12 43 45 54 30 12 10 55 60 73 44 10 8 76 83 93 57 8 6 96 110 117 75 6 4 120 125 148 94 4 3 143 152 166 109 3 2 160 171 191 124 2 1 186 197 215 145 1 1/0 215 229 244 169 1/0 2/0 251 260 273 198 2/0 3/0 288 297 308 227 3/0 4/0 332 346 361 260 4/0 250 — — — — 250 300 — — — — 300 350 — — — — 350 400 — — — — 400 500 — — — — 500 600 — — — — 600 700 — — — — 700 750 — — — — 750 800 — — — — 800 1000 — — — — 1000 1500 — — — — 1500 2000 — — — — 2000 Correction Factors Ambient For Ambient Temperatures Other Than 40°C (104°F), Multiply the Ambient Temp. °C Allowable Ampacities Shown Above By the Appropriate Factor Temp. °F Shown Below 41 – 50 .95 .97 .98 .95 105 – 122 51 – 60 .90 .94 .95 .90 123 – 140 61 – 70 .85 .90 .93 .85 141 – 158 71 – 80 .80 .87 .90 .80 159 – 176 81 – 90 .74 .83 .87 .74 177 – 194 91 – 100 .67 .79 .85 .67 195 – 212 101 – 120 .52 .71 .79 .52 213 – 248 121 – 140 .30 .61 .72 .30 249 – 284 141 – 160 — .50 .65 — 285 – 320 161 – 180 — .35 .58 — 321 – 356 181 – 200 — — .49 — 357 – 392 201 – 225 — — .35 — 393 – 437 � ® © Reprinted by permission from NFPA 70-2005. National Electrical Code , Copyright 2005. National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-226 XT IEC Power Control March 2009 Reference Data Enclosure Ratings The UL, NEMA and IEC organizations To comply to UL and IEC specifica- Table 34-265 is a comparison of the (and other international groups) define tions, the manufacturers must submit NEMA/UL/IEC enclosure specifications degrees of protection provided by product samples, materials used and to be used as an approximate refer- electrical enclosures with respect to other data to an independent testing ence only. Do not use the table to personnel, equipment within the laboratory before ratings can be convert from IEC to NEMA designa- housing and the ingress of water. claimed. tions. For a definition of the ratings 34 listed, see examples below and tables Subtle differences do exist between In addition, IEC “IP” ratings differ from on Page 34-227. the test procedures and specifications NEMA in that they do not apply to pro- of these organizations. tection against the risk of explosion or conditions such as humidity, corrosive To claim ratings to NEMA specifica- gases, fungi or vermin. In addition, tions, the testing is performed and cer- different parts of the equipment can tified by the manufacturers themselves. have different degrees of protection and still comply. Table 34-265. NEMA/UL/IEC Enclosure Type Cross-Reference — Approximate NEMA Enclo- sure Rating 1 XXXXX 2 XXXXX 3 XXXXXXXXXXXXXXXXXXXXXXXXX 3R XXXXXXXX 3S XXXXXXXXXXXXXXXXXXXXXXXXX 4 XXXXXXXXXXXXXXXXXXXXXXXXXXX 4X XXXXXXXXXXXXXXXXXXXXXXXXXXX 6 XXXXXXXXXXXXXXXXXXXXXXXXXXXX 6P XXXXXXXXXXXXXXXXXXXXXXXXXXXXX 12 XXXXXXXXXXXXXXXXXXXXXXXXXX 13 XXXXXXXXXXXXXXXXXXXXXXXXXX Note: IEC 529 does not specify equivalents to NEMA Enclosure Types 7, 8, 9 or 10. Table 34-266. IEC Environmental Enclosure Ratings — Examples of Designations IP 4 4 IP 2 3 Characteristic letters Characteristic letters 1st characteristic numeral 1st characteristic numeral (See Table 34-267 Next Page) (See Table 34-267 Next Page) 2nd characteristic numeral 2nd characteristic numeral (See Table 34-268 Next Page) (See Table 34-268 Next Page) An enclosure with this designation is protected against the An enclosure with this designation is protected against the penetration of solid objects greater than 1.0 mm and against penetration of solid objects greater than 12 mm and against splashing water. splashing water. For more information visit: www.eaton.com CA08102001E IP10 IP20 IP21 IP22 IP23 IP30 IP31 IP32 IP33 IP40 IP41 IP42 IP43 IP50 IP51 IP52 IP53 IP54 IP55 IP56 IP60 IP61 IP62 IP63 IP64 IP65 IP66 IP67 IP68 IEC Contactors & Starters 34-227 XT IEC Power Control March 2009 Reference Data Index of Enclosure Ratings — IEC NEC Definitions Pertaining to Hazardous Locations — Table 34-267. 1st Characteristic Numeral Table 34-268. 2nd Characteristic Numeral Protected against contact and penetration of 0 Not protected. Article 500 solid bodies. 1 Protection against dripping water. E51 Limit Switch Type Proximity 0 Not protected. 2 Protection against dripping water when Switches are rated for use in the fol- 1 Protection against solid objects greater tilted up to 15 degrees. lowing locations: than 50 mm. 3 Protection against rain. 34 Class I Division 2, Groups A, B, C or D — 2 Protection against solid objects greater 4 Protection against splashing water. than 12 mm. Indoor Use 5 Protection against water jets. 3 Protection against solid objects greater ■ For the definition of a Class I 6 Protection against heavy seas. than 2.5 mm. Division 2 location, see National 7 Protection against the effects of 4 Protection against solid objects greater Electrical Code Article 500-5, immersion. than 1.0 mm. paragraph (b). 8 Protection against submersion. 5 Dust protected. ■ For the definitions of Class I Group 6 Dust-tight. A, B, C, D Classifications, see the National Electrical Code Article 500-3, paragraph (a). NEMA Definitions Pertaining to Non-hazardous Locations — NEMA Standard 250 Class II Division 2, Groups F or G — Indoor Use Type 1 ■ For the definition of a Class II Enclosures are intended for indoor use, primarily to provide a degree of protection Division 2 location, see National against contact with the enclosed equipment. Electrical Code Article 500-6, paragraph (b). Type 3 ■ For the definitions of Class II Group Enclosures are intended for outdoor use, primarily to provide a degree of protec- F and G Classifications, see the tion against windblown dust, rain, sleet and external ice formation. National Electrical Code Article 500-3, paragraph (b). Type 3R Enclosures are intended for outdoor use, primarily to provide a degree of Class III Division 2 — Indoor Use protection against falling rain, sleet and external ice formation. ■ For the definition of a Class III Division 2 location, see National Type 4 Electrical Code Article 500-7, Enclosures are intended for indoor or outdoor use, primarily to provide a degree paragraph (b). of protection against windblown dust and rain, splashing water and hose-directed ■ For the definitions of Class III water. Classifications, see the National Type 4X Electrical Code Article 500-7. Enclosures are intended for indoor or outdoor use, primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water and hose-directed water. Type 6 Enclosures are intended for indoor or outdoor use, primarily to provide a degree of protection against the entry of water during occasional temporary submersion at a limited depth. Type 6P Enclosures are intended for indoor or outdoor use, primarily to provide a degree of protection against the entry of water during prolonged submersion at a limited depth. Type 12 Enclosures are intended for indoor use, primarily to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids. Type 13 Enclosures are intended for indoor use, primarily to provide a degree of protection against dust, spraying of water, oil and non-corrosive coolant. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-228 IT. Electro-Mechanical March 2009 Product Family Overview ISO 9002 Certification When you turn to Eaton’s Cutler-Hammer Products, you turn to quality. The Inter- national Standards Organization (ISO) has established a series of standards acknowledged by 91 industrialized nations to bring harmony to the international quest for quality. The ISO Certification process covers 20 quality system elements in design, production and installation that must conform to achieve registration. This commitment to quality will result in increased product reliability and total customer satisfaction. 34 Publications Pub. 49601 IT. IEC Overload Relay 27 mm (A-Frame) Quick Setup Guide Pub. 49602 IT. IEC Overload Relay (B – F Frames) Quick Setup Guide Pub. 49320 IT. IEC Non-reversing Contactor 27 mm (A-Frame) Installation Guide Pub. 49640 IT. IEC Non-reversing Contactor 45 mm (B-Frame) Installation Guide Pub. 49650 IT. IEC Non-reversing Contactor 54 mm (C-Frame) Installation Guide Pub. 49660 IT. IEC Non-reversing Contactor 76 mm (D-Frame) Installation Guide Pub. 49670 IT. IEC Non-reversing Contactor 105 mm (E-Frame) Installation Guide Pub. 49680 IT. IEC Non-reversing Contactor 140 mm (F-Frame) Installation Guide IEC, A Frame, Full Voltage Pub. 49321 IT. IEC Reversing Contactor 27 mm (A-Frame) Installation Guide Non-reversing and Reversing Starters Pub. 49641 IT. IEC Reversing Contactor 45 mm (B-Frame) Installation Guide Pub. 49651 IT. IEC Reversing Contactor 54 mm (C-Frame) Installation Guide Pub. 49661 IT. IEC Reversing Contactor 76 mm (D-Frame) Installation Guide Product Description Pub. 49671 IT. IEC Reversing Contactor 105 mm (E-Frame) Installation Guide ® Eaton’s Cutler-Hammer Intelligent Pub. 49681 IT. IEC Reversing Contactor 140 mm (F-Frame) Installation Guide Technologies (IT.) Electro-Mechanical Pub. 49322 IT. IEC Non-reversing Starter 27 mm (A-Frame) Installation Guide line of Contactors and Starters is the result of a substantial engineering, Pub. 49642 IT. IEC Non-reversing Starter 45 mm (B-Frame) Installation Guide manufacturing and marketing effort Pub. 49652 IT. IEC Non-reversing Starter 54 mm (C-Frame) Installation Guide involving extensive customer input, Pub. 49662 IT. IEC Non-reversing Starter 76 mm (D-Frame) Installation Guide combined with new advances in solid- state technology. IT. Electro-Mechanical Pub. 49672 IT. IEC Non-reversing Starter 105 mm (E-Frame) Installation Guide products have greatly increased Pub. 49682 IT. IEC Non-reversing Starter 140 mm (F-Frame) Installation Guide functionality, significantly reduced Pub. 49323 IT. IEC Reversing Starter 27 mm (A-Frame) Installation Guide size and utilize the benefits of 24V DC Pub. 49643 IT. IEC Reversing Starter 45 mm (B-Frame) Installation Guide control. The exclusive Pulse Width Modulation (PWM) control and digital Pub. 49653 IT. IEC Reversing Starter 54 mm (C-Frame) Installation Guide microprocessor generate a minimized Pub. 49663 IT. IEC Reversing Starter 76 mm (D-Frame) Installation Guide DC value which reduces energy to the Pub. 49673 IT. IEC Reversing Starter 105 mm (E-Frame) Installation Guide contact block and provides the most Pub. 49683 IT. IEC Reversing Starter 140 mm (F-Frame) Installation Guide compact system available. Pub. 49645 IT. IEC Non-reversing Contactor Assembly Instructions (45 mm & 54 mm) Pub. 49665 IT. IEC Non-reversing Contactor & Starter Assembly Instructions Standards and Certifications (76 mm Contactor/Starter) (45 mm & 54 mm Starter) ■ Designed to meet or exceed UL, IEC Pub. 49325 IT. IEC Non-reversing Starter 27 mm (A-Frame) Assembly Instructions and CSA Pub. 49685 IT. IEC Non-reversing Starter 140 mm (F-Frame) Assembly Instructions ■ UL Listed: UL File #E1491, Guide Pub. 49326 IT. IEC Reversing Starter 27 mm (A-Frame) Assembly Instructions #NLDX — Open, UL 508 Pub. 49686 IT. IEC Reversing Contactor & Starter 140 mm (F-Frame) Assembly ■ CSA Certified: CSA File #156828, Instructions Class #3211 04 Open, C22.2 Pub. 49410 IT. Front Mountable Auxiliary Contact Assembly Instructions No. 14-95 Pub. 49415 IT. IEC Contact Blocks (B – E Frames) ■ IEC: A – F Frames, IEC 60947-4-1, EN 60947-4-1 Pub. 282782 IT. Sinking Control Input Connections ■ 45 mm – 76 mm CSA Certified for Pub. 282719 IT. Overload Trip/Alarm Output (Sourcing/Sinking) Elevator Duty For copies of these and other publications, contact the Literature Fulfillment Center ■ CE at 800-957-7050, Fax: 877-840-2371 or find on-line at: ■ EMC IEC 61000-4 www.eaton.com. ■ KEMA For International, call: (630) 377-9738 (English only), Fax: (630) 377-1753. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-229 IT. Electro-Mechanical March 2009 Catalog Number Selection Catalog Number Selection (Open Components) Table 34-269. IT. Electro-Mechanical Catalog Numbering System E 101 A 12 A 3 A Overload Type Standard 34 A = Standard E = IEC (3-phase, 45 mm – 105 mm; 1- or 3-phase, 27 mm) N = Contactor or Not Applicable Configuration (Open Type) 02N = FVNR Coil Controller Pole Selection 03N = FVR Coil Controller 3 = 3-Pole 04N = Contact Block 05N = Solid-State Non-reversing Overload Relay 06N = Solid-State Reversing Overload Relay Overload Amperes Adjustment 101 = FVNR Starter 111 = FVNR Contactor (27 mm) (76 mm) 501 = FVR Starter A = .25 – .8 F = 5.0 – 16 511 = FVR Contactor B = .59 – 1.9 H = 8.4 – 27 C = 1.4 – 4.4 K = 14 – 45 D = 2.8 – 9.0 N = 31 – 100 Frame Size E = 3.8 – 12 A = 27 mm (45 mm) (105 mm) Designator (IEC) B = 45 mm A = .25 – .8 K = 14 – 45 C = 54 mm (A) (E) B = .59 – 1.9 M = 28 – 90 D = 76 mm 06 = 6 Amps. 12 = 125 Amps. C = 1.4 – 4.4 P = 42 – 135 E = 105 mm 09 = 9 Amps. 16 = 160 Amps. D = 2.8 – 9.0 R = 63 – 200 F = 140 mm 12 = 12 Amps. 20 = 200 Amps. G = 6.3 – 20 J = 10 – 32 (B) (F) 18 = 18 Amps. 25 = 250 Amps. (54 mm) (140 mm) 25 = 25 Amps. 31 = 315 Amps. A = .25 – .8 P = 42 – 135 32 = 32 Amps. 42 = 420 Amps. B = .59 – 1.9 S = 84 – 270 C = 1.4 – 4.4 T = 131 – 420 (C) XC = Coil Controller D = 2.8 – 9.0 40 = 40 Amps. XR = Overload X = Contact Block, Coil F = 5.0 – 16 50 = 50 Amps. Controller, Contactor or H = 8.4 – 27 Not Applicable (D) L = 16 – 50 65 = 65 Amps. 85 = 85 Amps. 10 = 100 Amps. Note: When using the Catalog Numbering System for Eaton’s Cutler-Hammer IT. Electro-Mechanical products, care should be exercised to assure that the Catalog Number for the Overload Relay aligns with the IT. Contact Block selected for type, frame size and ampacity, if purchased as separate components. Example: Select an E05N_XR_3A IT. Overload Relay for an IEC non-reversing application or an E06N_XR_3A for an IEC reversing application. Examples: E02NCXCXNN — FVNR Coil Controller, 54 mm E04NB18X3N — Contact Block, 45 mm, 18 Amps E05NCXRL3A — Solid-State Non-reversing Overload Relay, 16 – 50 Amps E101B32J3A — FVNR B-Frame Starter, 32 Amps, with Solid-State Overload, 10 – 32 Amps E111F25X3N — FVNR F-Frame Contactor, 250 Amps E501D10K3A — FVR D-Frame Starter, 100 Amps, with Solid-State Overload, 14 – 45 Amps E511B18X3N — FVR B-Frame Contactor, 18 Amps CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-230 IT. Electro-Mechanical March 2009 Contactors — Full Voltage, Non-reversing and Reversing ■ Unique Pulse Width Modulated Contents Product Description (PWM) coil controller minimizes Description Page ® energy and coil power consumption The Cutler-Hammer Intelligent Technologies (IT.) Electro-Mechanical Product Family Overview ■ Conformal coated PWM board Contactor from Eaton’s electrical (coil controller) for environmental Product Description. . . . . . . 34-228 business consists of an IT. Electro- toughness Standards and Mechanical Contact Block and IT. ■ Microprocessor-based control Certifications . . . . . . . . . . . 34-228 Electro-Mechanical Coil Controller ■ 95% humidity non-condensing 34 Publications . . . . . . . . . . . . . 34-228 as a Full Voltage Non-reversing (99% consult factory) (FVNR) or Full Voltage Reversing Catalog Number ■ Easily accessible mounting feet for (FVR) device. B-Frame (45 mm) to Selection . . . . . . . . . . . . . . 34-229 panel mounting E-Frame (105 mm) Contact Blocks Contactors — Non-reversing ■ High immunity to ESD, harmonics — combined with Coil Controllers and Reversing (factory or field assembled) are minimal Total Harmonic Distortion Product Description. . . . . . . 34-230 stand-alone Contactors. Only the ■ Front and side mounted Auxiliary A-Frame (27 mm) and F-Frame Contacts: 1NO, 1NC, 2NO, 2NC, Application Description. . . . 34-230 (140 mm) Contactors have internal 1NO/1NC and logic level Features . . . . . . . . . . . . . . . . 34-230 factory assembled coil controllers. ■ Built-in logic to provide either 2- or Product Selection . . . . . . . . 34-231 3-wire control, eliminating the need Also available are the IT. Manual and Technical Data and to provide and wire auxiliary con- Combination Motor Controllers which Specifications. . . . . . . . . . . . . 34-240 tacts to seal in and interlock the combine a Manual Motor Protector, contactor coils Accessories . . . . . . . . . . . . . . . . 34-244 Wiring Connector Link and IT. Contac- ■ Easy field assembly of control tor. See Tab 38 for more information. Auxiliary Contacts . . . . . . . . 34-246 wiring — plug and unplug lockable Renewal Parts. . . . . . . . . . . . . . 34-248 control connector Application Description Wiring Diagrams. . . . . . . . . . . . 34-249 ■ DIN rail mounting, 6 – 100A (A – D Frames) Dimensions . . . . . . . . . . . . . . . . 34-250 When selecting an IEC Contactor, the user must consider the specific load, ■ Common accessories utilization category and required elec- ■ Long-life silver nickel (A – B Frames) trical life. Actual application life may and silver tin oxide (C – F Frames) vary depending on environmental contacts provide excellent conduc- conditions and duty cycle. tivity and superior resistance to welding and arc erosion ■ Environmentally friendly materials Features ■ IP20 Finger Protection ■ 115V AC – 600V AC, 1/4 – 350 hp/ ■ Low wattage coils and minimal heat 3/4 – 250 kW, 50/60 Hz dissipation ■ 24V DC Coil Control — safe, reliable global standard Reversing Contactors ■ Most compact DC operated contac- ■ Includes Reversing Power Wiring tors available — e.g., A-Frame and bus bars IEC Full Voltage Non-reversing 27 mm wide, 7-1/2 hp @ 12A, 460V Contactor, C-Frame ■ Mounting plates for B-Frame ■ Frame sizes (mm): 27, 45, 54, 76, Cat. No. E111C50X3N (45 mm) to E-Frame (105 mm) 105, 140 ■ Exclusive internal electronic inter- ■ No laminations, shading coils or lock for reversing magnet noise ■ Unique coil controller energizes ■ -40 to 149°F (-40 to 65°C) both forward and reverse contactors operating temperature — one control point for wiring ■ No seal in auxiliary contacts required — control wiring is not needed between the contactor and overload relay IEC Full Voltage Reversing Contactor, D-Frame Cat. No. E511D10X3N For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-231 IT. Electro-Mechanical March 2009 Contactors — Full Voltage, Non-reversing and Reversing Product Selection When Ordering Select required contactor by amp rating, frame size, kW/hp, voltage and non- reversing or reversing. Non-reversing Contactors 34 Note: ■ An E111 (45 – 105 mm) consists of an E04N (Contact Block) and an E02N (FVNR Coil Controller), factory assembled. ■ An E111 (27 and 140 mm) has an internal coil controller, factory assembled. IEC A-Frame FVNR Contactor IEC B-Frame FVNR Contactor Cat. No. E111A12X3N Cat. No. E111B32X3N � Table 34-270. 3-Pole DC-Operated Full Voltage Non-reversing Contactors (A – F Frames) Max. IEC Frame Maximum kW Rating @ Ue (V) 50/60 Hz Maximum UL Horsepower (hp) 50/60 Hz 3-Pole Open Type AC-3 60947-4-1 Size 3-Phase 1-Phase 3-Phase � Amp. AC-1 220V/ 380V 400V/ 440V/ 500V 550V/ 115V/ 220V/ 200V/ 230V/ 380V/ 460V/ 575V/ Catalog Price Rating Thermal 240V 415V 460V 575V 120V 230V 208V 240V 415V 480V 600V Number U.S. $ 480V Current AC (le) 480V AC and (Ith) 6 12 A 1.1 2.2 2.2 3 3 3 1/4 1/2 1 1-1/2 3 3 3 E111A06X3N 9 16 A 2.2 4 4 4 4 4 1/3 1 2 2 3 5 5 E111A09X3N 12 20 A 3 5.5 5.5 6.5 6.5 6.5 1/2 2 3 3 5 7-1/2 7-1/2 E111A12X3N 18 25 B 4 7.5 9 9 10 11 1 3 5 5 10 10 10 E111B18X3N 25 40 B 5.5 12.5 12.5 13 15 15 2 3 5 7-1/2 10 15 15 E111B25X3N 32 50 B 9 15 15 18.5 18.5 18.5 2 5 7-1/2 10 15 20 20 E111B32X3N 40 63 C 11 18.5 22 22 22 25 3 7-1/2 10 10 20 25 25 E111C40X3N 50 85 C 12.5 22 25 30 30 33 3 10 15 15 25 30 30 E111C50X3N 65 100 D 18.5 30 33 40 40 45 5 10 20 20 40 50 50 E111D65X3N 85 115 D 25 45 45 51 51 55 7-1/2 15 25 30 50 60 60 E111D85X3N 100 130 D 25 51 55 59 59 63 10 20 30 30 50 75 75 E111D10X3N 125 200 E 33 63 63 80 80 80 10 25 40 40 60 100 100 E111E12X3N 160 225 E 45 80 80 100 100 100 15 30 50 60 75 125 125 E111E16X3N 200 250 E 59 100 110 110 110 132 — 40 60 75 100 150 150 E111E20X3N 250 300 F 75 132 140 160 160 160 — 50 75 100 150 200 200 E111F25X3N 315 375 F 90 160 160 200 200 200 — — 100 125 150 250 250 E111F31X3N 420 450 F 110 220 220 257 257 257 — — 150 150 200 350 350 E111F42X3N � 24V DC coil voltage. � Frame Size A = 27 mm B = 45 mm C = 54 mm D = 76 mm E = 105 mm F = 140 mm Note: ■ If required, accessories are available starting on Page 34-244. ■ Integral solid-state auxiliary hold-in circuit. ■ 3 main contacts. ■ See Table 34-279 for 24V DC power supply requirements. ■ Control inputs (P, F) are rated 24V DC (3 – 5 mA). Accessories . . . . . . . . . . Pages 34-244 – 34-247 Technical Data . . . . . . . . Pages 34-240 – 34-243 Dimensions . . . . . . . . . . . Pages 34-250 – 34-252 Discount Symbol . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-232 IT. Electro-Mechanical March 2009 Contactors — Full Voltage, Non-reversing and Reversing Reversing Contactors Note: ■ An E511 (45 – 105 mm) consists of two E04N (Contact Blocks), an E03N (FVR Coil Controller), Mechanical Interlock, Fanning Strips and Mounting Plate, factory assembled. ■ An E511F (140 mm) consists of two E111F 34 (Contactors), Mechanical Interlock, Crossover Bus Bars and Wiring Harness, factory assembled. ■ An E511A (27 mm) Contactor is factory assembled only. IEC B-Frame FVR Contactor Cat. No. E511B32X3N � Table 34-271. 3-Pole DC-Operated Full Voltage Reversing Contactors (A – F Frames) Max. IEC Frame Maximum kW Rating @ Ue (V) 50/60 Hz Maximum UL Horsepower (hp) 50/60 Hz 3-Pole Open Type AC-3 60947-4-1 Size 3-Phase 1-Phase 3-Phase � Amp. AC-1 220V/ 380V 400V/ 440V/ 500V 550V/ 115V/ 220V/ 200V/ 230V/ 380V/ 460V/ 575V/ Catalog Price Rating Thermal 240V 415V 460V 575V 120V 230V 208V 240V 415V 480V 600V Number U.S. $ 480V Current AC (le) 480V AC and (Ith) 6 12 A 1.1 2.2 2.2 3 3 3 1/4 1/2 1 1-1/2 3 3 3 E511A06X3N 9 16 A 2.2 4 4 4 4 4 1/3 1 2 2 3 5 5 E511A09X3N 12 20 A 3 5.5 5.5 6.5 6.5 6.5 1/2 2 3 3 5 7-1/2 7-1/2 E511A12X3N 18 25 B 4 7.5 9 9 10 11 1 3 5 5 10 10 10 E511B18X3N 25 40 B 5.5 12.5 12.5 13 15 15 2 3 5 7-1/2 10 15 15 E511B25X3N 32 50 B 9 15 15 18.5 18.5 18.5 2 5 7-1/2 10 15 20 20 E511B32X3N 40 63 C 11 18.5 22 22 22 25 3 7-1/2 10 10 20 25 25 E511C40X3N 50 85 C 12.5 22 25 30 30 33 3 10 15 15 25 30 30 E511C50X3N 65 100 D 18.5 30 33 40 40 45 5 10 20 20 40 50 50 E511D65X3N 85 115 D 25 45 45 51 51 55 7-1/2 15 25 30 50 60 60 E511D85X3N 100 130 D 25 51 55 59 59 63 10 20 30 30 50 75 75 E511D10X3N 125 200 E 33 63 63 80 80 80 10 25 40 40 60 100 100 E511E12X3N 160 225 E 45 80 80 100 100 100 15 30 50 60 75 125 125 E511E16X3N 200 250 E 59 100 110 110 110 132 — 40 60 75 100 150 150 E511E20X3N 250 300 F 75 132 140 160 160 160 — 50 75 100 150 200 200 E511F25X3N 315 375 F 90 160 160 200 200 200 — — 100 125 150 250 250 E511F31X3N 420 450 F 110 220 220 257 257 257 — — 150 150 200 350 350 E511F42X3N � 24V DC coil voltage. � Frame Size A = 27 mm B = 45 mm C = 54 mm D = 76 mm E = 105 mm F = 140 mm Note: ■ If required, accessories are available starting on Page 34-244. ■ Integral solid-state auxiliary hold-in circuit. ■ 3 main contacts. ■ See Table 34-279 for 24V DC power supply requirements. ■ Control inputs (P, F, R) are rated 24V DC (3 – 5 mA). Accessories . . . . . . . . . . . Pages 34-244 – 34-247 Technical Data . . . . . . . . Pages 34-240 – 34-243 Dimensions . . . . . . . . . . . Pages 34-250 – 34-252 Discount Symbol . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-233 IT. Electro-Mechanical March 2009 Starters — Full Voltage, Non-reversing and Reversing ■ LED status indication — trip, trip Contents class, motor thermal state, reset, Description Page overload state Product Family Overview ■ Unique “Alarm without Trip” option for critical must run applications Product Description . . . . . . 34-228 ■ Lockable overload cover protects Standards and against unauthorized adjustment Certifications . . . . . . . . . . 34-228 and reset functions Publications . . . . . . . . . . . . 34-228 34 ■ No control wiring needed between Catalog Number contactor and overload relay — Selection . . . . . . . . . . . . . 34-229 eliminates seal in auxiliary contacts Starters — Non-reversing ■ Minimal heat — no full voltage coils and Reversing ■ -40° to 149°F (-40° to 65°C) operating Product Description . . . . . . 34-233 temperature Features . . . . . . . . . . . . . . . 34-233 ■ Wide 3.2:1 current adjustment range IEC Full Voltage Reversing Product Selection. . . . . . . . 34-234 Starter, E Frame ■ Exclusive internal 24-bit floating Technical Data and Cat. No. E501E20R3A point math calculations with RMS Specifications . . . . . . . . . . . . 34-240 calibrated current measurement Accessories . . . . . . . . . . . . . . . 34-244 ■ High immunity to ESD, harmonics — Product Description Auxiliary Contacts . . . . . . . 34-246 minimal Total Harmonic Distortion Renewal Parts . . . . . . . . . . . . . 34-248 ■ IP20 Finger Protection ® The Cutler-Hammer Intelligent Tech- ■ Motor running thermal utilization Wiring Diagrams . . . . . . . . . . . 34-249 nologies (IT.) Electro-Mechanical indication Starter from Eaton’s electrical business Dimensions . . . . . . . . . . . . . . . 34-250 consists of an IT. Electro-Mechanical ■ Manual, Automatic or Remote Reset Contact Block or Contactor and IT. ■ Easy field assembly of control Electro-Mechanical Solid-State Over- wiring — plug and unplug lockable load Relay as a Full Voltage Non- control connector reversing (FVNR) or Full Voltage ■ DIN rail mounting, 6A – 100A (A – D Reversing (FVR) device. A-Frame (27 Frames) mm) to F-Frame (140 mm) Starters are ■ Communication Interface with factory or field assembled. Starter Network Adapter Product (SNAP) IEC FVNR Starter, Features C Frame ■ 2- or 3-wire control Cat. No. E101C50L3A ■ Solid-state alarm output indication ■ 115V AC – 600V AC, 1/4 – 350 hp/ ■ Front and side mounted Auxiliary .75 – 250 kW, .25A – 420A Overload Contacts: 1NO, 1NC, 2NO, 2NC, Amperes range, 50/60 Hz 1NO/1NC, logic level (1NO/1NC) ■ 24V DC coil control power — safe, ■ Type 2 Coordination reliable, global standard ■ Conformal coated PWM overload ■ Unique Pulse Width Modulated board for environmental toughness (PWM) coil controller minimizes energy and coil power consumption Reversing Starters ■ Microprocessor based control ■ Includes Reversing Power Wiring ■ Phase loss and current unbalance and bus bars protection, user selectable ■ Mounting plates for B-Frame ■ Standard user-selectable Trip Class (45 mm) to E-Frame (105 mm) 10 (factory default), 20 or 30 — no individual part numbers — no pro- ■ Built-in electronic interlock for FVR Overload Relay with Cover gramming software units Open — FLA/Trip Class/ Phase Protection Dial ■ Ambient compensated ■ Unique overload board energizes both forward and reverse starters — ■ Motor temperature and power-up TEST Button RESET Button one control point for wiring protection with thermal memory ■ Easily accessible mounting feet for panel mounting ■ For use on the load side of an Adjustable Frequency Drive, con- sult the factory. Overload Relay with Cover Closed (front view) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-234 IT. Electro-Mechanical March 2009 Starters — Full Voltage, Non-reversing and Reversing Product Selection When Ordering Select required Starter by kW/hp rating, voltage, phase and overload adjustment range (amperes). 34 IEC A-Frame, Full Voltage IEC B-Frame, Full Voltage Non-reversing Starter Non-reversing Starter Non-reversing Starters Table 34-272. Full Voltage Non-reversing DC-Operated, Open Type Starters (A – B Frames), with 3-Pole Solid-State Overload Protection Max. Overload Maximum kW Rating @ Ue (V) Maximum UL Horsepower (hp) Rating Catalog Price AC-3 Amp. Adjustment 50/60 Hz 50/60 Hz Number U.S. $ Rating Range 3-Phase 1-Phase 3-Phase 480V AC (le) (Amperes) 220V/ 380V 400V/ 460V 500V 550V/ 115V/ 220V/ 200V/ 230V/ 380V/ 460V/ 575V/ 240V 415V 575V 120V 230V 208V 240V 415V 480V 600V A-Frame 27 mm 6 .25 – .8 1.1 2.2 2.2 3 3 3 1/4 1/2 1 1-1/2 3 3 3 E101A06A3A .59 – 1.9 E101A06B3A 1.4 – 4.4 E101A06C3A 2.8 – 9.0 E101A06D3A 3.8 – 12 E101A06E3A 9 .25 – .8 2.2 4 4 4 4 4 1/3 1 2 2 3 5 5 E101A09A3A .59 – 1.9 E101A09B3A 1.4 – 4.4 E101A09C3A 2.8 – 9.0 E101A09D3A 3.8 – 12 E101A09E3A 12 .25 – .8 35.5 5.5 6.5 6.5 6.5 1/2 2335 7-1/2 7-1/2 E101A12A3A .59 – 1.9 E101A12B3A 1.4 – 4.4 E101A12C3A 2.8 – 9.0 E101A12D3A 3.8 – 12 E101A12E3A B-Frame 45 mm 18 .25 – .8 4 7.5 9 9 10 11 — — 5 5 10 10 10 E101B18A3A .59 – 1.9 E101B18B3A 1.4 – 4.4 E101B18C3A 2.8 – 9.0 E101B18D3A 6.3 – 20 E101B18G3A 10 – 32 E101B18J3A 25 .25 – .8 5.5 12.5 12.5 13 15 15 — — 5 7-1/2 10 15 15 E101B25A3A .59 – 1.9 E101B25B3A 1.4 – 4.4 E101B25C3A 2.8 – 9.0 E101B25D3A 6.3 – 20 E101B25G3A 10 – 32 E101B25J3A 32 .25 – .8 915 1518.5 18.5 18.5 — — 7-1/2 10 15 20 20 E101B32A3A .59 – 1.9 E101B32B3A 1.4 – 4.4 E101B32C3A 2.8 – 9.0 E101B32D3A 6.3 – 20 E101B32G3A 10 – 32 E101B32J3A Note: ■ Class 10 (factory default), 20 and 30 Trip ■ See Table 34-279 for 24V DC power supply Times see Figure 34-150 on Page 34-243. requirements. ■ If required, accessories are available starting ■ An E101 (27 – 105 mm) consists of an E04N ■ Control inputs (P, F, 1) are rated 24V DC on Page 34-244. (Contact Block) or E111A (Contactor) and an (3 – 5 mA). ■ A-Frame 27 mm IT. Starter is for 1 – or E05N (Non-reversing Overload Relay), 3-phase applications. factory assembled. An E101F (140 mm) ■ The standard B – F-Frame (45 mm to 140 mm) consists of an E111 (Contactor) and an E05N IT. Starters are for 3-phase applications. (Non-reversing Overload Relay), factory assembled. Accessories . . . . . . . . . . . Pages 34-244 – 34-247 Technical Data . . . . . . . . Pages 34-240 – 34-243 Dimensions . . . . . . . . . . . Pages 34-253 – 34-255 Discount Symbol . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-235 IT. Electro-Mechanical March 2009 Starters — Full Voltage, Non-reversing and Reversing 34 IEC C-Frame FVNR Starter Non-reversing Starters, continued Table 34-273. Full Voltage Non-reversing DC-Operated, Open Type Starters (C – D Frames), with 3-Pole Solid-State Overload Protection Max. Overload Maximum kW Rating @ Ue (V) Maximum UL Horsepower (hp) Rating Catalog Price AC-3 Amp. Adjustment 50/60 Hz 50/60 Hz Number U.S. $ Rating Range 3-Phase 1-Phase 3-Phase 480V AC (le) (Amperes) 220V/ 380V 400V/ 460V 500V 550V/ 115V/ 220V/ 200V/ 230V/ 380V/ 460V/ 575V/ 240V 415V 575V 120V 230V 208V 240V 415V 480V 600V C-Frame 54 mm 40 .25 – .8 11 18.5 22 22 22 25 — — 10 10 20 25 25 E101C40A3A .59 – 1.9 E101C40B3A 1.4 – 4.4 E101C40C3A 2.8 – 9.0 E101C40D3A 5.0 – 16 E101C40F3A 8.4 – 27 E101C40H3A 16 – 50 E101C40L3A 50 .25 – .8 12.5 22 25 30 30 33 — — 15 15 25 30 30 E101C50A3A .59 – 1.9 E101C50B3A 1.4 – 4.4 E101C50C3A 2.8 – 9.0 E101C50D3A 5.0 – 16 E101C50F3A 8.4 – 27 E101C50H3A 16 – 50 E101C50L3A D-Frame 76 mm 65 5.0 – 16 18.5 30 33 40 40 45 — — 20 20 40 50 50 E101D65F3A 8.4 – 27 E101D65H3A 14 – 45 E101D65K3A 31 – 100 E101D65N3A 85 5.0 – 16 25 45 45 51 51 55 — — 25 30 50 60 60 E101D85F3A 8.4 – 27 E101D85H3A 14 – 45 E101D85K3A 31 – 100 E101D85N3A 100 5.0 – 16 25 51 55 59 59 63 — — 30 30 50 75 75 E101D10F3A 8.4 – 27 E101D10H3A 14 – 45 E101D10K3A 31 – 100 E101D10N3A Note: ■ Class 10 (factory default), 20 and 30 Trip ■ See Table 34-279 for 24V DC power supply Times see Figure 34-150 on Page 34-243. requirements. ■ If required, accessories are available starting ■ An E101 (27 – 105 mm) consists of an E04N ■ Control inputs (P, F, 1) are rated 24V DC on Page 34-244. (Contact Block) or E111A (Contactor) and an (3 – 5 mA). ■ A-Frame 27 mm IT. Starter is for 1 – or E05N (Non-reversing Overload Relay), 3-phase applications. factory assembled. An E101F (140 mm) ■ The standard B – F-Frame (45 mm to 140 mm) consists of an E111 (Contactor) and an E05N IT. Starters are for 3-phase applications. (Non-reversing Overload Relay), factory assembled. Accessories . . . . . . . . . . Pages 34-244 – 34-247 Technical Data . . . . . . . . Pages 34-240 – 34-243 Dimensions . . . . . . . . . . . Pages 34-253 – 34-255 Discount Symbol . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-236 IT. Electro-Mechanical March 2009 Starters — Full Voltage, Non-reversing and Reversing 34 IEC F- and E-Frame (105 mm and 140 mm) Full Voltage Non-reversing Starters Non-reversing Starters, continued Table 34-274. Full Voltage Non-reversing DC-Operated, Open Type Starters (E – F Frames) with 3-Pole Solid-State Overload Protection Max. Overload Maximum kW Rating @ Ue (V) Maximum UL Horsepower (hp) Rating Catalog Price AC-3 Amp. Adjustment 50/60 Hz 50/60 Hz Number U.S. $ Rating Range 3-Phase 1-Phase 3-Phase 480V AC (le) (Amperes) 220V/ 380V 400V/ 460V 500V 550V/ 115V/ 220V/ 200V/ 230V/ 380V/ 460V/ 575V/ 240V 415V 575V 120V 230V 208V 240V 415V 480V 600V E-Frame 105 mm 125 14 – 45 33 63 63 80 80 80 — — 40 40 60 100 100 E101E12K3A 28 – 90 E101E12M3A 42 – 135 E101E12P3A 63 – 200 E101E12R3A 160 14 – 45 45 80 80 100 100 100 — — 50 60 75 125 125 E101E16K3A 28 – 90 E101E16M3A 42 – 135 E101E16P3A 63 – 200 E101E16R3A 200 14 – 45 59 100 110 110 110 132 — — 60 75 100 150 150 E101E20K3A 28 – 90 E101E20M3A 42 – 135 E101E20P3A 63 – 200 E101E20R3A F-Frame 140 mm 250 42 – 135 75 132 140 160 160 160 — — 75 100 150 200 200 E101F25P3A 84 – 270 E101F25S3A 131 – 420 E101F25T3A 315 42 – 135 90 160 160 200 200 200 — — 100 125 150 250 250 E101F31P3A 84 – 270 E101F31S3A 131 – 420 E101F31T3A 420 42 – 135 110 220 220 257 257 257 — — 150 150 200 350 350 E101F42P3A 84 – 270 E101F42S3A 131 – 420 E101F42T3A Note: ■ Class 10 (factory default), 20 and 30 Trip ■ See Table 34-279 for 24V DC power supply Times see Figure 34-150 on Page 34-243. requirements. ■ If required, accessories are available starting ■ An E101 (27 – 105 mm) consists of an E04N ■ Control inputs (P, F, 1) are rated 24V DC on Page 34-244. (Contact Block) or E111A (Contactor) and an (3 – 5 mA). ■ A-Frame 27 mm IT. Starter is for 1 – or E05N (Non-reversing Overload Relay), 3-phase applications. factory assembled. An E101F (140 mm) ■ The standard B – F-Frame (45 mm to 140 mm) consists of an E111 (Contactor) and an E05N IT. Starters are for 3-phase applications. (Non-reversing Overload Relay), factory assembled. Accessories . . . . . . . . . . . Pages 34-244 – 34-247 Technical Data . . . . . . . . Pages 34-240 – 34-243 Dimensions . . . . . . . . . . . Pages 34-253 – 34-255 Discount Symbol . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-237 IT. Electro-Mechanical March 2009 Starters — Full Voltage, Non-reversing and Reversing 34 IEC A-Frame Reversing Starter Reversing Starters � Table 34-275. Full Voltage Reversing DC-Operated, Open Type Starters (A – B Frames) with 3-Pole Solid-State Overload Protection Max. Overload Maximum kW Rating @ Ue (V) Maximum UL Horsepower (hp) Rating Catalog Price AC-3 Amp. Adjustment 50/60 Hz 50/60 Hz Number U.S. $ Rating Range 3-Phase 1-Phase 3-Phase 480V AC (le) (Amperes) 220V/ 380V 400V/ 440V/ 500V 550V/ 115V/ 220V/ 200V/ 230V/ 380V/ 460V/ 575V/ 240V 415V 460V 575V 120V 230V 208V 240V 415V 480V 600V A-Frame 27 mm 6 .25 – .8 1.1 2.2 2.2 3 3 3 1/4 1/2 1 1-1/2 3 3 3 E501A06A3A .59 – 1.9 E501A06B3A 1.4 – 4.4 E501A06C3A 2.8 – 9.0 E501A06D3A 3.8 – 12 E501A06E3A 9 .25 – .8 2.2 4 4 4 4 4 1/3 1 2 2 3 5 5 E501A09A3A .59 – 1.9 E501A09B3A 1.4 – 4.4 E501A09C3A 2.8 – 9.0 E501A09D3A 3.8 – 12 E501A09E3A 12 .25 – .8 3 5.5 5.5 6.5 6.5 6.5 1/2 2 3 3 5 7-1/2 7-1/2 E501A12A3A .59 – 1.9 E501A12B3A 1.4 – 4.4 E501A12C3A 2.8 – 9.0 E501A12D3A 3.8 – 12 E501A12E3A B-Frame 45 mm 18 .25 – .8 4 7.5 9 9 10 11 — — 5 5 10 10 10 E501B18A3A .59 – 1.9 E501B18B3A 1.4 – 4.4 E501B18C3A 2.8 – 9.0 E501B18D3A 6.3 – 20 E501B18G3A 10 – 32 E501B18J3A 25 .25 – .8 5.5 12.5 12.5 13 15 15 — — 5 7-1/2 10 15 15 E501B25A3A .59 – 1.9 E501B25B3A 1.4 – 4.4 E501B25C3A 2.8 – 9.0 E501B25D3A 6.3 – 20 E501B25G3A 10 – 32 E501B25J3A 32 .25 – .8 915 15 18.5 18.5 18.5 — — 7-1/2 10 15 20 20 E501B32A3A .59 – 1.9 E501B32B3A 1.4 – 4.4 E501B32C3A 2.8 – 9.0 E501B32D3A 6.3 – 20 E501B32G3A 10 – 32 E501B32J3A � 24V DC coil voltage. ■ An E501 (45 – 105 mm) consists of two E04N ■ See Table 34-279 for 24V DC power supply (Contact Blocks), an E06N (Reversing requirements. Note: Overload Relay), Fanning Strips, Mechanical ■ Control inputs (P, F, R, 1) are rated 24V DC ■ If required, accessories are available starting Interlock and Mounting Plate. An E501F (3 – 5 mA). on Page 34-244. (140 mm) consists of two E111F (Contactors), ■ A-Frame 27 mm IT. Starter is for 1 – or an E06NF (Reversing Overload Relay), 3-phase applications. Mechanical Interlock, Crossover Bus Bars and ■ The standard B – F-Frame (45 mm to 140 mm) Reversing Wiring Harness. IT. Starters are for 3-phase applications. ■ An E501A (27 mm) consists of an E511A Accessories . . . . . . . . . . Pages 34-244 – 34-247 (Contactor) and E06NA (Reversing Overload Relay). Technical Data . . . . . . . . Pages 34-240 – 34-243 Dimensions . . . . . . . . . . . Pages 34-253 – 34-255 Discount Symbol . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-238 IT. Electro-Mechanical March 2009 Starters — Full Voltage, Non-reversing and Reversing 34 IEC C-Frame Reversing Starter Reversing Starters, continued � Table 34-276. Full Voltage Reversing DC-Operated, Open Type Starters (C – D Frames) with 3-Pole Solid-State Overload Protection Max. Overload Maximum kW Rating @ Ue (V) Maximum UL Horsepower (hp) Rating Catalog Price AC-3 Amp. Adjustment 50/60 Hz 50/60 Hz Number U.S. $ Rating Range 3-Phase 1-Phase 3-Phase 480V AC (le) (Amperes) 220V/ 380V 400V/ 440V/ 500V 550V/ 115V/ 220V/ 200V/ 230V/ 380V/ 460V/ 575V/ 240V 415V 460V 575V 120V 230V 208V 240V 415V 480V 600V C-Frame 54 mm 40 .25 – .8 11 18.5 22 22 22 25 — — 10 10 20 25 25 E501C40A3A .59 – 1.9 E501C40B3A 1.4 – 4.4 E501C40C3A 2.8 – 9.0 E501C40D3A 5.0 – 16 E501C40F3A 8.4 – 27 E501C40H3A 16 – 50 E501C40L3A 50 .25 – .8 12.5 22 25 30 30 33 — — 15 15 25 30 30 E501C50A3A .59 – 1.9 E501C50B3A 1.4 – 4.4 E501C50C3A 2.8 – 9.0 E501C50D3A 5.0 – 16 E501C50F3A 8.4 – 27 E501C50H3A 16 – 50 E501C50L3A D-Frame 76 mm 65 5.0 – 16 18.5 30 33 40 40 45 — — 20 20 40 50 50 E501D65F3A 8.4 – 27 E501D65H3A 14 – 45 E501D65K3A 31 – 100 E501D65N3A 85 5.0 – 16 25 45 45 51 51 55 — — 25 30 50 60 60 E501D85F3A 8.4 – 27 E501D85H3A 14 – 45 E501D85K3A 31 – 100 E501D85N3A 100 5.0 – 16 25 51 55 59 59 63 — — 30 30 50 75 75 E501D10F3A 8.4 – 27 E501D10H3A 14 – 45 E501D10K3A 31 – 100 E501D10N3A � 24V DC coil voltage. ■ An E501 (45 – 105 mm) consists of two E04N ■ See Table 34-279 for 24V DC power supply (Contact Blocks), an E06N (Reversing requirements. Note: Overload Relay), Fanning Strips, Mechanical ■ Control inputs (P, F, R, 1) are rated 24V DC ■ If required, accessories are available starting Interlock and Mounting Plate. An E501F (3 – 5 mA). on Page 34-244. (140 mm) consists of two E111F (Contactors), ■ A-Frame 27 mm IT. Starter is for 1 – or an E06NF (Reversing Overload Relay), 3-phase applications. Mechanical Interlock, Crossover Bus Bars and ■ The standard B – F-Frame (45 mm to 140 mm) Reversing Wiring Harness. IT. Starters are for 3-phase applications. ■ An E501A (27 mm) consists of an E511A (Contactor) and E06NA (Reversing Overload Relay). Accessories . . . . . . . . . . . Pages 34-244 – 34-247 Technical Data . . . . . . . . Pages 34-240 – 34-243 Dimensions . . . . . . . . . . . Pages 34-253 – 34-255 Discount Symbol . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-239 IT. Electro-Mechanical March 2009 Starters — Full Voltage, Non-reversing and Reversing 34 IEC E-Frame FVR Starter IEC F-Frame Cat. No. E501E20P3A Reversing Starter Reversing Starters, continued � Table 34-277. Full Voltage Reversing DC-Operated, Open Type Starters (E – F Frames) with 3-Pole Solid-State Overload Protection Max. Overload Maximum kW Rating @ Ue (V) Maximum UL Horsepower (hp) Rating Catalog Price AC-3 Amp. Adjustment 50/60 Hz 50/60 Hz Number U.S. $ Rating Range 3-Phase 1-Phase 3-Phase 480V AC (le) (Amperes) 220V/ 380V 400V/ 440V/ 500V 550V/ 115V/ 220V/ 200V/ 230V/ 380V/ 460V/ 575V/ 240V 415V 460V 575V 120V 230V 208V 240V 415V 480V 600V E-Frame 105 mm 125 14 – 45 33 63 63 80 80 80 — — 40 40 60 100 100 E501E12K3A 28 – 90 E501E12M3A 42 – 135 E501E12P3A 63 – 200 E501E12R3A 160 14 – 45 45 80 80 100 100 100 — — 50 60 75 125 125 E501E16K3A 28 – 90 E501E16M3A 42 – 135 E501E16P3A 63 – 200 E501E16R3A 200 14 – 45 59 100 110 110 110 132 — — 60 75 100 150 150 E501E20K3A 28 – 90 E501E20M3A 42 – 135 E501E20P3A 63 – 200 E501E20R3A F-Frame 140 mm 250 42 – 135 75 132 140 160 160 160 — — 75 100 150 200 200 E501F25P3A 84 – 270 E501F25S3A 131 – 420 E501F25T3A 315 42 – 135 90 160 160 200 200 200 — — 100 125 150 250 250 E501F31P3A 84 – 270 E501F31S3A 131 – 420 E501F31T3A 420 42 – 135 110 220 220 257 257 257 — — 150 150 200 350 350 E501F42P3A 84 – 270 E501F42S3A 131 – 420 E501F42T3A � 24V DC coil voltage. ■ An E501 (45 – 105 mm) consists of two E04N ■ See Table 34-279 for 24V DC power supply (Contact Blocks), an E06N (Reversing requirements. Note: Overload Relay), Fanning Strips, Mechanical ■ Control inputs (P, F, R 1) are rated 24V DC ■ If required, accessories are available on Interlock and Mounting Plate. An E501F (3 – 5 mA). Page 34-244. (140 mm) consists of two E111F (Contactors), ■ A-Frame 27 mm IT. Starter is for 1 – or an E06NF (Reversing Overload Relay), 3-phase applications. Mechanical Interlock, Crossover Bus Bars and ■ The standard B – F-Frame (45 mm to 140 mm) Reversing Wiring Harness. IT. Starters are for 3-phase applications. ■ An E501A (27 mm) consists of an E511A (Contactor) and E06NA (Reversing Overload Relay). Accessories . . . . . . . . . . Pages 34-244 – 34-247 Technical Data . . . . . . . . Pages 34-240 – 34-243 Dimensions . . . . . . . . . . . Pages 34-253 – 34-255 Discount Symbol . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-240 IT. Electro-Mechanical March 2009 Technical Data and Specifications Table 34-278. Specifications Description A-Frame B-Frame C-Frame D-Frame E-Frame F-Frame 27 mm 45 mm 54 mm 76 mm 105 mm 140 mm � Overall Dimensions in Inches (mm) — w x h x d Non-reversing 1.1 x 3.0 x 2.4 1.8 x 4.4 x 2.4 2.1 x 4.4 x 2.4 3.0 x 5.9 x 3.1 4.1 x 8.0 x 3.5 5.6 x 14.0 x 7.0 Contactor (27 x 75 x 60) (45 x 111 x 60) (54 x 113 x 60) (76 x 150 x 79) (105 x 203 x 90) (142 x 356 x 178) Reversing 2.4 x 2.9 x 2.4 3.8 x 5.9 x 2.7 4.5 x 5.9 x 2.6 6.2 x 7.4 x 3.3 8.5 x 9.5 x 3.8 11.7 x 17.2 x 7.0 Contactor (60 x 73 x 60) (96 x 149 x 69) (114 x 149 x 67) (158 x 188 x 84) (216 x 242 x 97) (297 x 437 x 178) 34 Non-reversing 1.2 x 4.0 x 3.1 1.8 x 5.0 x 2.5 2.1 x 5.4 x 2.5 3.0 x 5.9 x 3.1 4.1 x 8.0 x 3.5 5.7 x 19.4 x 7.0 Starter (31 x 102 x 79) (45 x 127 x 63) (54 x 138 x 63) (76 x 150 x 79) (105 x 203 x 90) (145 x 493 x 178) Reversing 2.5 x 4.0 x 3.1 3.8 x 5.9 x 2.7 4.5 x 5.9 x 2.6 6.2 x 7.4 x 3.3 8.5 x 9.5 x 3.8 11.8 x 21.0 x 7.0 Starter (64 x 102 x 79) (96 x 149 x 69) (114 x 149 x 67) (158 x 188 x 84) (216 x 242 x 97) (300 x 533 x 178) Mounting Hole Spacing in Inches (mm) — w x h Non-reversing .76 x 2.64 1.33 x 4.0 1.46 x 4.10 .94 x 2.87 1.33 x 4.13 1.75 x 13.0 Contactor (19.2 x 67) (33.8 x 101) (37 x 104) (24 x 73) (33.8 x 105) (44.5 x 330) Reversing 1.31 x 2.52 3.15 x 5.35 3.15 x 5.35 5.51 x 6.89 7.87 x 9.06 7.82 x 13.0 Contactor (33.2 x 64) (80 x 136) (80 x 136) (140 x 175) (200 x 230) (199 x 330) Non-reversing .76 x 3.70 1.33 x 4.62 1.46 x 5.04 .94 x 2.87 1.33 x 4.13 1.75 x 18.3 Starter (19.3 x 94.0) (33.8 x 117.3) (37 x 128) (24 x 73) (33.8 x 105) (44.5 x 465) Reversing 1.31 x 3.52 3.15 x 5.35 3.15 x 5.35 5.51 x 6.89 7.87 x 9.06 7.82 x 18.3 Starter (33.2 x 89.4) (80 x 136) (80 x 136) (140 x 175) (200 x 230) (198.5 x 465) Mounting Positions Panel-Vertical Yes Yes Yes Yes Yes Yes Panel-Horizontal Yes Yes Yes Yes Yes Yes � � � DIN Rail Mountable Yes Yes Yes Yes No No Weights in Lb. (kg) Non-reversing .3 .7 .9 2.8 6.7 20 Contactor (.14) (.31) (.42) (1.27) (3.05) (9.1) Reversing .6 1.9 2.6 6.9 16.9 48 Contactor (.27) (.86) (1.17) (3.13) (7.67) (21.8) Non-reversing .4 .9 1.2 2.9 7.1 27 Starter (.18) (.40) (.53) (1.32) (3.20) (12.3) Reversing .9 2.0 2.6 7.1 16.8 55 Starter (.40) (.90) (1.20) (3.20) (7.60) (25.0) Mechanical Operating Rate Maximum 6/sec 3/sec 3/sec 2/sec 2/sec 1/sec Mechanical Life 23,000,000 10,000,000 10,000,000 8,000,000 8,000,000 5,000,000 Humidity � 95% 95% 95% 95% 95% 95% non-condensing non-condensing non-condensing non-condensing non-condensing non-condensing Insulation Voltage (Ui) 690V 690V 690V 690V 690V 690V Impulse Withstand Voltage (Uimp) 6 kV 6 kV 6 kV 6 kV 6 kV 6 kV Max. Current Ratings @ 480V Ue AC-1 20 50 85 130 250 450 Thermal Current (Ith) AC-2, AC-3 12 32 50 100 200 420 Operating Current (Ie) AC-4 10 32 50 100 150 270 Operating Current (Ie) Max. Current Ratings @ 600V Ue AC-1 16 40 68 104 200 360 Thermal Current (Ith) AC-2, AC-3 925 40 80 160 336 Operating Current (Ie) AC-4 8 18 34 68 120 150 Operating Current (Ie) � Auxiliaries add approximately 1.0" (25 mm) to depth for single, 1.2" (30 mm) for dual. � Non-reversing contactors and starters only. � 99% by application. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-241 IT. Electro-Mechanical March 2009 Technical Data and Specifications Table 34-278. Specifications (Continued) Description A-Frame B-Frame C-Frame D-Frame E-Frame F-Frame 27 mm 45 mm 54 mm 76 mm 105 mm 140 mm Finger Protection Front IP20 IP20 IP20 IP20 IP20 IP00 At Terminals IP20 IP10 IP10 IP00 IP00 IP00 At Terminals with IP20 IP20 IP10 IP10 IP00 IP00 max. size wire 34 installed � Terminals L1, L2, L3/T1, T2, T3 1 Wire per Terminal 16 – 12 AWG 14 – 8 AWG 14 – 4 AWG 14 – 1 AWG 6 – 250 MCM 4 – 750 MCM 2 2 2 2 2 2 (stranded or solid) (1.5 – 2.5 mm ) (1.5 – 10 mm ) (1.5 – 16 mm ) (1.5 – 35 mm ) (16 – 120 mm ) (25 – 420 mm ) � 2 Wires per Terminal 16 – 12 AWG 14 – 10 AWG 14 – 6 AWG 14 – 2 AWG 6 – 3/0 AWG 1/0 – 300 MCM 2 2 2 2 2 2 (stranded or solid) (1.5 – 2.5 mm ) (1.5 – 4 mm ) (1.5 – 16 mm ) (1.5 – 25 mm ) (16 – 70 mm ) (50 – 150 mm ) Strip Length .32" (8 mm) .45" (11 mm) .5" (12 mm) .7" (18 mm) .8" (21 mm) 1.5" (40 mm) Torque (max.) 18 lb-in (2.0 20 lb-in (2.2 Nm) for 35 lb-in (4.0 Nm) for 45 lb-in (5.0 Nm) for Single 250 lb-in 550 lb-in 2 Nm) 14 – 10 AWG 14 – 10 AWG (1.5 – 6 14 – 8 AWG (1.5 – 10 mm ); (28 Nm) (62 Nm) 2 2 (1.5 – 6 mm ); mm ); 100 lb-in (11 Nm) for Single 2 25 lb-in (2.8 Nm) for 40 lb-in (4.5 Nm) for 6 – 1 AWG (16 – 35 mm ) 2 2 8 AWG (10 mm ) 8 AWG (10 mm ); and Dual Wire Combina- 45 lb-in (5.0 Nm) for tions 2 6 – 4 AWG (16 mm ) Driver Flat PZ1 or 3/16" — — — — — Hex Key — 2.5 mm 3 mm 4 mm [5/32"] 8 mm [5/16"] 8 mm [5/16"] Operation Performance Coil Voltage (nominal) 24V DC 24V DC 24V DC 24V DC 24V DC 24V DC Coil Operating 20 – 28 20 – 28 20 – 28 20 – 28 20 – 28 20 – 28 Voltage Range (VDC) Control Terminals � (- and +) 14 – 12 AWG 14 – 12 AWG 14 – 12 AWG 14 – 12 AWG 14 – 12 AWG 14 – 12 AWG 2 2 2 2 2 2 1 Wire per Terminal (1.5 – 2.5 mm ) (1.5 – 2.5 mm ) (1.5 – 2.5 mm ) (1.5 – 2.5 mm ) (1.5 – 2.5 mm ) (1.5 – 2.5 mm ) � (- and +) 14 AWG 14 AWG 14 AWG 14 AWG 14 AWG 14 AWG 2 2 2 2 2 2 2 Wires per Terminal (1.5 mm ) (1.5 mm ) (1.5 mm ) (1.5 mm ) (1.5 mm ) (1.5 mm ) � (P, F, R, 1, 2, 3) 22 – 12 AWG 22 – 12 AWG 22 – 12 AWG 22 – 12 AWG 22 – 12 AWG 22 – 12 AWG 2 2 2 2 2 2 1 Wire per Terminal (0.5 – 2.5 mm ) (0.5 – 2.5 mm ) (0.5 – 2.5 mm ) (0.5 – 2.5 mm ) (0.5 – 2.5 mm ) (0.5 – 2.5 mm ) � (P, F, R, 1, 2, 3) 18 – 14 AWG 18 – 14 AWG 18 – 14 AWG 18 – 14 AWG 18 – 14 AWG 18 – 14 AWG 2 2 2 2 2 2 2 Wires per Terminal (0.75 – 1.5 mm ) (0.75 – 1.5 mm ) (0.75 – 1.5 mm ) (0.75 – 1.5 mm ) (0.75 – 1.5 mm ) (0.75 – 1.5 mm ) Torque (max.) 4.5 lb-in (.5 Nm) 4.5 lb-in (.5 Nm) 4.5 lb-in (.5 Nm) 4.5 lb-in (.5 Nm) 4.5 lb-in (.5 Nm) 4.5 lb-in (.5 Nm) Strip Length .25 (7 mm) .25 (7 mm) .25 (7 mm) .25 (7 mm) .25 (7 mm) .25 (7 mm) � Driver (Flat) .13 (3.5 mm) .13 (3.5 mm) .13 (3.5 mm) .13 (3.5 mm) .13 (3.5 mm) .13 (3.5 mm) � Temperature Operating -40° to +149°F -40° to +149°F -40° to +149°F -40° to +149°F -40° to +149°F -40° to +149°F (-40° to +65°C) (-40° to +65°C) (-40° to +65°C) (-40° to +65°C) (-40° to +65°C) (-40° to +65°C) Storage -58° to +176°F -58° to +176°F -58° to +176°F -58° to +176°F -58° to +176°F -58° to +176°F (-50° to +80°C) (-50° to +80°C) (-50° to +80°C) (-50° to +80°C) (-50° to +80°C) (-50° to +80°C) � Use Class B 75°C copper wire only (or 90°C copper wire sized for 75°C operation per NEC). � Not applicable to starter T1, T2, T3. One wire per terminal. � 27 mm Non-reversing Starter — 2 • (- and +) 14 AWG (1.5 mm ) only • P, F, 1, A: 1 wire per terminal only, 2 22 – 14 AWG (0.5 – 1.5 mm ) • Torque: 2.25 lb-in (.25 Nm) • Driver: .09 in (2.5 mm) � Consult factory for higher ratings. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-242 IT. Electro-Mechanical March 2009 Technical Data and Specifications Table 34-278. Specifications (Continued) Description A-Frame B-Frame C-Frame D-Frame E-Frame F-Frame 27 mm 45 mm 54 mm 76 mm 105 mm 140 mm Environmental � Shock/Vibration 15G/5G 15G/5G 15G/5G 15G/5G 15G/5G 15G/5G � Pollution Degree 2 2 2 2 2 2 EMC Environment 1 1 1 1 1 1 � Altitude in Ft. (m) 6600 (2000) 6600 (2000) 6600 (2000) 6600 (2000) 6600 (2000) 6600 (2000) 34 Pull-In Time (mS) @ 24V DC Excl. Debounce Time 15 15 15 25 30 70 – 200 � � Incl. Debounce Time 67 75 80 88 95 120 – 250 Dropout Time (mS) @ 24V DC Excl. Debounce Time 8 5 5 12 15 50 – 150 � � Incl. Debounce Time 60 65 70 75 80 70 – 200 � Consult factory for higher ratings. Note: � Add 50 mS for 27 and 140 mm Starters for additional microprocessor. ■ Response time for Control Inputs = Debounce Time � The Non-reversing Starter requires the use of all six mounting screws ■ The time between operating forward and reverse must be greater than for the maximum rating. the Debounce Time. Note: At other temperatures expressed in °C, for either inrush or Table 34-279. 24V DC Power Supply Requirements @ 68°F (20°C) (see sealed, use the 20°C value from the table in the following: �� Note at bottom left) Watts = W [1.1 – .005(T) and 20 Contactor/Starter Size Sealed In Inrush Amps = A [1.1 – .005(T)] 20 For example, inrush requirements for a Catalog Frame/ Wattage Amps Wattage Amps Duration � D-Frame Starter at -25°C would be: Number mm (mS) Watts = 130 [1.1 – .005 (-25)] = 160 E_11A__X3N A/27 1.3 .054 20 .83 30 Amps = 5.4 [1.1 – .005 (-25)] = 6.6 E_01A___3A A/27 2.0 .083 20 .83 30 E_11B__X3N B/45 3.7 .15 80 3.3 50 E_01B___3A B/45 3.2 .13 80 3.3 50 E_11C__X3N C/54 4.2 .18 90 3.8 50 E_01C___3A C/54 3.6 .15 90 3.8 50 E__1D___3_ D/76 5.0 .21 130 5.4 65 E__1E___3_ E/105 5.6 .23 140 5.8 85 E__1F__X3N F/140 12.0 .50 200 8.3 250 E_01F___3A F/140 13.0 .54 200 8.3 250 � The sum of the sealed in values of the contactors/starters must be less than the power supply sealed in value. The largest contactor/starter inrush value must be less than the power supply inrush value. � Refer to Tab 44 for further power supply information. � _ indicates missing digit/character of the Catalog Number; may have multiple values. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-243 IT. Electro-Mechanical March 2009 Technical Data and Specifications Electrical Life — AC-1, AC-2, AC-3 and AC-4 Utilization Categories Table 34-280. Utilization Categories The International Electrotechnical Commission (IEC) has developed utilization categories for contactors and auxiliary contacts. The categories describe the type of electrical load and the conditions for making and breaking the current. Category Typical Application AC-1 Non-inductive or slightly inductive loads: Resistance furnaces, heating. AC-2 Slip-ring motors: Starting and stopping of running motors 34 AC-3 Squirrel cage motors: Starting, switching off motors during running (motors in most industrial applications typically fall into this cate- gory). � � AC-4 Squirrel cage motors: Starting, plugging , inching (very few applications in industry are totally AC-4). � Plugging is stopping or reversing the motor rapidly by reversing the connections while the motor is running. � Inching or jogging is energizing the motor once or repeatedly for short durations to obtain small movements of the motor driven load. Note: AC-3 tests are conducted at rated Life Load Curves — Eaton’s Cutler- Trip Times device currents and AC-4 tests are con- Hammer IT. Electro-Mechanical Series ducted at six-times rated device currents. IEC contactors have been designed All tests have been run at 460V, 60 Hz. and manufactured for superior life 1000.0 performance. All testing has been Actual application life may vary, based on requirements as found in IEC depending on environmental condi- 60947-4-1 and conducted by us. When tions and application duty cycle. selecting a contactor designed to IEC requirements, the specifier must give 100.0 attention to the specific load, utiliza- tion category and the required electri- cal life. For a definition of Utilization Categories, see Table 34-280 above. 10.0 5 Frame Size 3 AB C D E F 10,000,000 6 1 4 2 1,000,000 1.0 100,000 0.1 12 3 4 5 6 7 8 9 10 Multiples of FLA 10,000 169 12 18 32 50 85125 200 315 10 25 40 65 100 160 250 420 1 Trip Class 10 Cold Operational Current Note: Preliminary data. 2 Trip Class 10 Hot 3 Trip Class 20 Cold 4 Trip Class 20 Hot Figure 34-148. Electrical Life — AC-3 Utilization Category 5 Trip Class 30 Cold 6 Trip Class 30 Hot Frame Size Figure 34-150. Class 10, 20 and 30 Trip Curves AB CDEF 10,000,000 Contactor Choice — ■ Decide what utilization category the application is and choose the 1,000,000 appropriate curve from Figure 34- 148 or Figure 34-149. ■ Locate the intersection of the life- load curve with the operational cur- 100,000 rent (le) of the application, as found on the horizontal axis. ■ Read the estimated contact life 10,000 along the vertical axis in number of 0.1 1 6 9 18 32 50 85125 250 operations. 10 25 40 65 100 148 320 Operational Current Note: Preliminary data. Figure 34-149. Electrical Life — AC-4 Utilization Category CA08102001E For more information visit: www.eaton.com Operations Operations Trip Time (Seconds) IEC Contactors & Starters 34-244 IT. Electro-Mechanical March 2009 Accessories Modular Components — Contactor Field Assembly IEC Non-reversing FVNR Contact Block Coil Controller Contactor 34 EXAMPLE FOR A FULL VOLTAGE NON-REVERSING CONTACTOR: E04NC50X3N + E02NCXCXNN = E111C50X3N Reversing Kit (2) IEC Reversing Coil Mounting FVR Mechanical (2) Fanning Strips Contact Blocks Controller Plate Contactor Interlock EXAMPLE FOR A FULL VOLTAGE REVERSING CONTACTOR: (2) E04NC50X3N + E03NCXCXNN + EMRKTC (REVERSING KIT) = E511C50X3N Figure 34-151. Modular Contactor Assembly Modular Components — Starter Field Assembly FVNR IEC Non-reversing Starter Contact Block Overload Relay Reversing Kit EXAMPLE FOR A FULL VOLTAGE NON-REVERSING STARTER: E04NC50X3N + E05NCXRL3A = E101C50L3A Mounting FVR (2) IEC Reversing Mechanical (2) Fanning Strips Plate Starter Contact Blocks Overload Relay Interlock EXAMPLE FOR A FULL VOLTAGE REVERSING STARTER: (2) E04NC50X3N + E06NCXRL3A + EMRKTC (REVERSING KIT) = E501C50L3A Figure 34-152. Modular Starter Assembly For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-245 IT. Electro-Mechanical March 2009 Accessories IEC Contact Block IEC Solid-State Overload Relay 34 B Frame Non-reversing Reversing Table 34-281. IEC Contact Block Frame Amperes Catalog Price Number U.S. $ Table 34-283. IEC Solid-State Overload Relay Frame Overload Catalog Price B-Frame 18 E04NB18X3N Adjustment Range Number U.S. $ 45 mm 25 E04NB25X3N (Amperes) 32 E04NB32X3N Non-reversing C-Frame 40 E04NC40X3N 54 mm 50 E04NC50X3N A-Frame .25 – .8 E05NAXRA3A 27 mm .59 – 1.9 E05NAXRB3A D-Frame 65 E04ND65X3N 1.4 – 4.4 E05NAXRC3A 76 mm 85 E04ND85X3N 2.8 – 9.0 E05NAXRD3A 100 E04ND10X3N 3.8 – 12 E05NAXRE3A E-Frame 125 E04NE12X3N B-Frame .25 – .8 E05NBXRA3A 105 mm 160 E04NE16X3N 45 mm .59 – 1.9 E05NBXRB3A 200 E04NE20X3N 1.4 – 4.4 E05NBXRC3A Note: 2.8 – 9.0 E05NBXRD3A 6.3 – 20 E05NBXRG3A ■ E04N + E05N = E101; E04N + E02N = E111 (45 – 105 mm) 10 – 32 E05NBXRJ3A ■ E04N + E06N = E501; E04N + E03N = E511 (45 – 105 mm) C-Frame .25 – .8 E05NCXRA3A 54 mm .59 – 1.9 E05NCXRB3A IEC Coil Controller 1.4 – 4.4 E05NCXRC3A 2.8 – 9.0 E05NCXRD3A 5.0 – 16 E05NCXRF3A 8.4 – 27 E05NCXRH3A 16 – 50 E05NCXRL3A D-Frame 5.0 – 16 E05NDXRF3A 76 mm 8.4 – 27 E05NDXRH3A 14 – 45 E05NDXRK3A 31 – 100 E05NDXRN3A B Frame E-Frame 14 – 45 E05NEXRK3A Non-reversing 105 mm 28 – 90 E05NEXRM3A 42 – 135 E05NEXRP3A Table 34-282. IEC Coil Controller 63 – 200 E05NEXRR3A Frame Catalog Price F-Frame 42 – 135 E05NFXRP3A Number U.S. $ 140 mm 84 – 270 E05NFXRS3A Non-reversing 131 – 420 E05NFXRT3A B-Frame — 45 mm E02NBXCXNN Reversing C-Frame — 54 mm E02NCXCXNN B-Frame .25 – .8 E06NBXRA3A D-Frame — 76 mm E02NDXCXNN 45 mm .59 – 1.9 E06NBXRB3A 1.4 – 4.4 E06NBXRC3A E-Frame — 105 mm E02NEXCXNN 2.8 – 9.0 E06NBXRD3A F-Frame — 140 mm EMUCCF 6.3 – 20 E06NBXRG3A Reversing 10 – 32 E06NBXRJ3A B-Frame — 45 mm E03NBXCXNN C-Frame .25 – .8 E06NCXRA3A 54 mm .59 – 1.9 E06NCXRB3A C-Frame — 54 mm E03NCXCXNN 1.4 – 4.4 E06NCXRC3A D-Frame — 76 mm E03NDXCXNN 2.8 – 9.0 E06NCXRD3A E-Frame — 105 mm E03NEXCXNN 5.0 – 16 E06NCXRF3A F-Frame — 140 mm EMUCCF 8.4 – 27 E06NCXRH3A 16 – 50 E06NCXRL3A D-Frame 5.0 – 16 E06NDXRF3A 76 mm 8.4 – 27 E06NDXRH3A 14 – 45 E06NDXRK3A 31 – 100 E06NDXRN3A E-Frame 14 – 45 E06NEXRK3A 105 mm 28 – 90 E06NEXRM3A 42 – 135 E06NEXRP3A 63 – 200 E06NEXRR3A Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-246 IT. Electro-Mechanical March 2009 Accessories Auxiliary Contacts are available for Table 34-286. IEC Ratings Auxiliary Contacts mounting on IT. Electro-Mechanical DC-13 AC-15 Contactors and Starters. The various U l U l e e e e choices available for non-reversing Voltage Amps. Voltage Amps. models are shown in Tables 34-284 24 5 488 and 34-285, and their ratings in Tables 48 2.5 120 6 34-286 – 34-288. For reversing models, 125 1.1 240 4 the number of auxiliaries indicated is 250 .55 440 2 34 for each of the contactors/starters in the assembly. Table 34-287. NEMA A600 Ratings Current AC Voltage Table 34-284. Auxiliary Contact Availability — A – F Frames 120 240 480 600 � Front Mounted (Maximum Auxiliaries per Contactor/Starter) Make and 60 30 15 12 Contactor/Starter Size Contact Catalog Price Interrupting Type Number U.S. $ A-Frame B-Frame C-Frame D-Frame E-Frame F-Frame Break 6 3 1.5 1.2 27 mm 45 mm 54 mm 76 mm 105 mm 140 mm Continuous 10 10 10 10 1 3 33 3— 1NO EMA13 Thermal 10 10 10 10 1 3 33 3— 1NC EMA14 Table 34-288. NEMA P300 Ratings � —2 2 3 3 — 1NO-1NC EMA15 Current DC Voltage � —2 2 3 3 — 2NO EMA16 125 250 � —2 2 3 3 — 2NC EMA17 Make and 1.1 .55 1 2 3 3 3 3 Logic Level EMA70 Interrupting 1NO-1NC Break 1.1 .55 � Other combinations: “Single, dual, single”; “Dual, single, dual”; “Dual, logic level, dual”. Continuous 5 5 � For reversers, multiply quantities by two. Thermal 5 5 EMA13 EMA14 EMA15 EMA16 EMA17 EMA70 Table 34-289. EMA70 Auxiliary Contact DC-12 AC-12 3 1 13 21 13 23 11 21 4 2 Ue Ie Ue Ie NO NC NO NC NO NO NC NC NO NC 30 .1 250 .1 4 2 14 22 14 24 12 22 1 1 Common Starter Network Adapter Product (SNAP) Figure 34-153. Connecting Diagram — A – F Frames Table 34-285. Auxiliary Contact Availability — F-Frame 140 mm Auxiliary Contacts per Non-reversing and Reversing Contactor or Starter Max. Contact Description Catalog Price Type Number U.S. $ 2 1NO Base auxiliary (max. 1 per side) C320KGS41 2 1NO-1NC Base auxiliary (max. 1 per side) C320KGS42 6 1NO C320KGS41 or C320KGS42 required C320KGS20 Cat. No. D77B-DSNAP-X1 (max. 3 Add-on auxiliaries per side) with 54 mm IT. Starter 2 1NO C320KGS41 or C320KGS42 required C320KGS20L Logic Level (max. 1 Add-on auxiliary per side) The Starter Network Adapter Product 6 1NC C320KGS41 or C320KGS42 required C320KGS21 (SNAP) is a front-mount device that (max. 2 Add-on auxiliaries per side) serves as a single DeviceNet node, pro- 2 1NC C320KGS41 or C320KGS42 required C320KGS21L viding communication capability, control Logic Level (max. 1 Add-on auxiliary per side) and monitoring to Eaton’s Cutler-Ham- 2 1NO-1NC C320KGS41 or C320KGS42 required C320KGS22 mer Intelligent Technologies (IT.) Electro- (max. 1 Add-on auxiliary per side) mechanical Starters (B – F Frames) as � 2 1NO-1NC C320KGS41 or C320KGS42 required C320KGS22L well as the IT. S75X SoftStart. Logic Level (max. 1 Add-on auxiliary per side) � When HAND-OFF-AUTO is required, 3 1NO-1NC Front Mounted Only EMA70 Logic Level the HOA option will allow for the con- � nection of hard wired operators. This Form C Contacts. � option allows for Hand Control even if For reversers, multiply quantities by two. the DSNAP is not connected. Note: ■ Side Mounted: Maximum (10) total circuits. For more information and pricing, see � ■ Front Mounted: Maximum (6) total circuits. Tab 50. ■ Maximum 4 auxiliaries per side (base + 3 side mounted). ■ EMASA/B_ have been superseded by the above Catalog Numbers. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-247 IT. Electro-Mechanical March 2009 Accessories IEC Reversing Mounting Plates IEC Mechanical Interlock Table 34-292. IEC Mechanical Interlock Frame Catalog Price � Size Number U.S. $ B – E EMMB � F C321KM50 � The A-Frame 27 mm does not have a separate mechanical interlock 34 due to its embedded design and board requirements. � The F-Frame 140 mm uses the Freedom Series Mechanical Interlock. IEC 2-Wire Reversing Interface Table 34-290. IEC Reversing Mounting Plates Frame Catalog Price Table 34-293. IEC 2-Wire Reversing Interface Size Number U.S. $ Description Catalog Price Number U.S. $ B – C EMA9B D EMA9D 8-Pin for 45 – 140 mm (IEC 6A – 420A EMA2WR8 Reversing Starters) E EMA9E 8-Pin for 45 – 105 mm (IEC 18A – 200A Reversing Contactors) IEC Reversing Kits Table 34-291. IEC Reversing Kits DIN Rail Catch Frame Description Catalog Price Size Number U.S. $ � B For Contactor and Starter EMRKTB � C For Contactor and Starter EMRKTC � D For Contactor and Starter EMRKTD � E For Contactor and Starter EMRKTE � F For Contactor EMRKTF � Includes Fanning Strips, Mechanical Interlock, Mounting Plate and hardware. � Includes Fanning Strips (Bus Bar Set), Mechanical Interlock and Table 34-294. DIN Rail Catch hardware. Frame Description Catalog Price Size Number U.S. $ IEC Control Terminals B – C Catch with Leaf Spring and Pad EMDRCB D Catch with Leaf Spring and Pad EMDRCD Table 34-295. IEC Control Terminals No. Terminal IEC Coil Controller Contactor Overload Starter Catalog Price of Markings Size Number U.S. $ Non- Reversing Non- Reversing Non- Reversing Non- Reversing Pins reversing reversing reversing reversing 8 -+PFR123 A X X EMA76L B X XXXXX C X XXXXX D XXXXXXXX E XXXXXXXX F XXXX 5 -+PFR F XXXX EMA77L 5 RFP+- F XXXX EMA77LR 4 -+PF A X EMA78L BX X CX X � 6 -+PF1A A X X EMA81 � (2) 5 -+PFR and RFP+- F X X EMA80L � Non-locking. � Consists of (1) EMA77L and (1) EMA77LR inter-wired. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-248 IT. Electro-Mechanical March 2009 Renewal Parts IEC Contact Kits Fanning Strips Table 34-298. Reversing Fanning Strips Frame Description Catalog Price Size Number U.S. $ A Line and Load Side Wire Sets EMFRA B Line Side EMFRLB Load Side EMFRTB 34 C Line Side EMFRLC Load Side EMFRTC D Line Side EMFRLD Load Side EMFRTD Table 34-296. IEC Contact Kits E Line Side EMFRLE Frame Description Catalog Price Load Side EMFRTE Size Number U.S. $ F Line Side Bus Bar Set EMFRLF � C 3-Pole, 40A EMCKT40 Load Side Bus Bar Set EMFRTF � 3-Pole, 50A EMCKT50 � D 3-Pole, 65A EMCKT65 � Lug Kits 3-Pole, 85A EMCKT85 � 3-Pole, 100A EMCKT100 E 3-Pole, 125A EMCKT125 3-Pole, 160A EMCKT160 3-Pole, 200A EMCKT200 F 3-Pole, 250A EMCKT250 3-Pole, 315A EMCKT315 3-Pole, 420A EMCKT420 � Includes set of Hold Open and Non-hold Open movable contacts. 24V DC Coils Table 34-297. 24V DC Coils Table 34-299. Lug Kits Frame Catalog Price Frame Description Catalog Price Size Number U.S. $ Size Number U.S. $ B EMCB C 3 pc. EMLUGKTC C EMCC D 1 pc. EMLUGKTD D EMCD E 1 pc. — For Contactor and Line EMLUGKTLE E EMCE Side Starter F EMCF 1 pc. — For Load Side Starter EMLUGKTTE � F Horizontal Box Lug EMLUGKTFA Vertical Box Lug EMLUGKTFB � Kit includes Lug Cover — required for contactors only. Table 34-300. Ring Lug Retrofit Kits Product IEC A-Frame IEC E-Frame IEC F-Frame Catalog Number Catalog Number Catalog Number Factory Retrofit Lug Factory Retrofit Lug Factory Retrofit Lug � � � � � � Installed Kits Kits Installed Kits Kits Installed Kits Kits E111 EMRTXKTA Add “-RTX” EMRTXKTEN EMLUGREN Add “-RTX” EMRTXKTF EMLUGRFC E511 EMRTXKTA Add “-RTX” EMRTXKTER EMLUGRER Add “-RTX” EMRTXKTF EMLUGRFC E101 EMRTXKTA Add “-RTX” EMRTXKTEN EMLUGREN Add “-RTX” EMRTXKTF EMLUGRFS E501 EMRTXKTA Add “-RTX” EMRTXKTER EMLUGRER Add “-RTX” EMRTXKTF EMLUGRFS E05N Add “-RTX” Add “-RTX” E06N Add “-RTX” Add “-RTX” E02N Add “-RTX” E03N Add “-RTX” E04N Add “-RTX” � Retrofit Kits used to field install ring lugs on standard lug units. � Lug Kits used to field install standard lugs into factory assembled ring lug units. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-249 IT. Electro-Mechanical March 2009 Wiring Diagrams 1L1 3L2 5L3 3-Wire Control 2-Wire Control Power Power Supply Supply 24V DC 24V DC 24V DC M E-Stop E-Stop PF P F P F 2T1 4T2 6T3 34 24V DC Optional Stop Optional * Connections Control Terminal Block Start M 3~ * Maintained Only = Momentary = Maintained Disconnect AC Power Before Working on this Product 2-Wire Remote Pilot Device Figure 34-154. Wiring – Non-reversing Contactor Alarm Output A 1L1 3L2 5L3 24V DC 3-Wire Control 2-Wire Control Power Power PF 1 A Supply Supply 24V DC 24V DC E-Stop E-Stop PF 1 A PF 1 A 24V DC Connections 2T1 4T2 6T3 Control Stop Terminal Block Optional Optional * STATUS TEST Note: Load side wires pass Reset Start Auto through the overload (Optional) RESET Manual and are secured with the contactor terminals, T1, T2 and T3. Reset M (Optional) 3~ Alarm Output (Optional) 1L1 3L2 5L3 3-Wire Control 2-Wire Control Power Power Supply Supply 24V DC 24V DC E-Stop E-Stop PF N 12 3 PF N 12 3 RESET Stop STATUS Optional Optional Manual * TEST Auto Start Reset (Optional) Reset M (Optional) 24V DC 3~ Note: PF N 1 2 3 Remove Control Terminal Block before = Momentary wiring of T1, T2 and T3. 24V DC = Maintained Connections Control Terminal Block * Maintained Only Disconnect AC Power Before Working on this Product 2-Wire Remote Pilot Device Figure 34-155. Wiring – Non-reversing Starters CA08102001E For more information visit: www.eaton.com 24V DC 24V DC 24V DC Permissive Permissive Permissive Forward Forward Forward Not Used Reset Reset Optional Alarm Optional Alarm 24V DC 24V DC Permissive Permissive Forward Forward Reset 24V DC Optional Alarm Permissive Forward Not Used Reset Optional Alarm IEC Contactors & Starters 34-250 IT. Electro-Mechanical March 2009 Dimensions Non-reversing and Reversing Contactors (Frame A) Table 34-301. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Mtg. Terminals Size Screws Width Height Depth Depth w/ Depth added Width Height Mtg. Hole DIN Rail Control Line Load Auxiliary w/DIN Rail to Top to Top AB C D E F G H J K P Q R Non-reversing 34 A 1.1 3.0 2.4 3.5 .2 .76 2.64 .1 .6 (3) #8 .6 1.7 1.7 (27) (75) (60) (88) (5) (19.2) (67) (3.5) (15) M4 (16) (43) (43) Reversing A 2.4 2.9 2.4 3.5 .2 1.31 2.52 .2 .5 (3) #8 .6 1.7 1.7 (60) (73) (60) (88) (5) (33.2) (64) (5) (13) M4 (16) (43) (43) D C A A H Q Line Terminals F (1 L1, 3 L2, 5 L3) J J Logic Level Auxiliary – Reduce Dim “D” .28 (7) for the Standard Single Auxiliaries G G B B DIN Rail 1.38 x .3 (35 x 7.5) (Optional Mounting) K K F E Control P Terminal R Load Terminals Non-reversing Reversing Block (2 T1, 4 T2, 6 T3) Contactors Contactors Figure 34-156. Approximate Dimensions — Inches (mm) Non-reversing Contactors (Frames B & C) Table 34-302. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Mtg. Terminals Size Screws Width Height Depth Depth w/ Depth added Width Height Mtg. Hole DIN Rail Control Line Load Auxiliary w/DIN Rail to Top to Top AB C D E F G H J K P Q R B1.8 4.4 2.4 3.6 .1 1.33 4.0 .2 .9 (3) #8 .7 1.2 1.2 (45) (111) (60) (91) (3) (33.8) (101) (5) (23) M4 (19) (30) (30) C 2.1 4.45 2.4 3.6 .1 1.46 4.1 .2 .8 (3) #8 .7 1.2 1.2 (54) (113) (60) (91) (3) (37) (104) (5) (20) M4 (19) (30) (30) D A H C F Line Terminals Q (1 L1, 3 L2, 5 L3) J Dual Auxiliary – Reduce Dim “D” .31 (8) for the Single Auxiliaries Standard DIN Rail B G 1.38 x .3 (35 x 7.5) (Optional Mounting) Load Terminals (2 T1, 4 T2, 6 T3) Control E P K Terminal Block R C-Frame Pictured (B-Frame Has Two Lower Mtg. Feet, Reference F – Width) Figure 34-157. Approximate Dimensions — Inches (mm) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-251 IT. Electro-Mechanical March 2009 Dimensions Non-reversing Contactors (Frames D & E) Table 34-303. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Mtg. Terminals Size Screws Width Height Depth Depth w/ Depth added Width Height Mtg. Hole DIN Rail Control Line Load Auxiliary w/DIN Rail to Top to Top AB C D E F G H J K P Q R D 3.0 5.9 3.1 4.2 .2 .94 2.87 .5 .9 (4) #6 x 2 2.4 1.5 .6 34 (76) (150) (79) (107) (4) (24) (73) (13) (23) M3.5 x 50 (60) (37) (14) E 4.1 8.0 3.5 4.7 — 1.33 4.13 .6 — (4) #8 x 1.5 2.8 1.7 .3 (105) (203) (90) (119) (33.8) (105) (15) M4 x 40 (72) (42) (8) D Line Terminals (1 L1, 3 L2, 5 L3) A Q H E F J Dual Auxiliary – Reduce Dim “D” .31 (8) for the G Standard Single Auxiliaries DIN Rail K B 1.38 x .3 (35 x 7.5) (Optional Mounting) 76 mm (D-Frame) Only 2T1 4 T2 6 T3 Load Terminals Control (2 T1, 4 T2, 6 T3) R Terminal Block P E-Frame Shown C Figure 34-158. Approximate Dimensions — Inches (mm) Non-reversing Contactors (Frame F) Table 34-304. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Mtg. Terminals Size Screws Width Height Depth Depth w/Logic Width w/Side Width Height Mounting Control Line Load Level Auxiliary Auxiliaries Hole to Top A BCD E F G H K P Q R F 5.6 14.0 7.0 8.2 6.70 1.75 13.0 0.58 (4) 5/16 .8 4.4 4.4 (142) (356) (178) (208) (170) (44.5) (330) (14.7) M8 (20) (112) (112) D E C A H Line Terminals Q K F (1 L1, 3 L2, 5 L3) B G Side Auxiliary Logic Auxiliary Control Terminal Block P Load Terminals R (2 T1, 4 T2, 6 T3) Figure 34-159. Approximate Dimensions in Inches (mm) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-252 IT. Electro-Mechanical March 2009 Dimensions Reversing Contactors (Frames B – E) Table 34-305. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Mtg. Terminals Size Screws Width Height Depth Depth w/ Width Height Mtg. Hole Control Line Load Auxiliary to Top AB C D F G H K P Q R B3.8 5.9 2.7 3.8 3.15 5.35 .3 (3) #10 2.0 1.5 .9 34 (96) (149) (69) (96) (80) (136) (7) M5 (50) (38) (22) C 4.5 5.9 2.6 3.8 3.15 5.35 .3 (3) #10 2.0 1.5 .6 (114) (149) (67) (96) (80) (136) (7) M5 (50) (38) (16) D 6.2 7.4 3.3 4.4 5.51 6.89 .2 (3) #10 2.6 1.9 .9 (158) (188) (84) (112) (140) (175) (6) M5 (67) (48) (22) E 8.5 9.5 3.8 4.9 7.87 9.06 .2 (3) #10 3.1 2.1 .7 (216) (242) (97) (125) (200) (230) (6) M5 (80) (54) (17) D H K Line Terminals Q (1 L1, 3 L2, 5 L3) Dual Auxiliary – Reduce Dim “D” .31 (8) for the Single Auxiliaries G B Load Terminals R F Control (2 T1, 4 T2, 6 T3) Terminal Block P A C Figure 34-160. Approximate Dimensions — Inches (mm) Reversing Contactors (Frame F) Table 34-306. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Mtg. Terminals Size Screws Width Height Depth Depth w/Logic Width w/Side Width Height Mounting Control Line Load Level Auxiliary Auxiliaries Hole to Top A BCD E F G H K P Q R F 11.7 17.2 7.0 8.2 12.8 7.8 13.0 2.19 (4) 5/16 .8 4.4 4.4 (297) (437) (178) (208) (325) (198.5) (330) (55.5) M8 (20) (112) (112) D E C A Line Terminals Q F K (1 L1, 3 L2, 5 L3) H B G Side Auxiliary Logic Auxiliary Control Terminal Block P Load Terminals R (2 T1, 4 T2, 6 T3) Figure 34-161. Approximate Dimensions in Inches (mm) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-253 IT. Electro-Mechanical March 2009 Dimensions Non-reversing and Reversing Starters (Frame A) Table 34-307. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Mtg. Reset Button Terminals Size Screws Width Height Depth Depth w/ Depth added Width Height Mtg. Hole DIN Rail Width Height Depth Control Line Load Auxiliary w/DIN Rail to Top to Top AB C D E F G H J K L M N P Q R Non-reversing 34 A 1.20 4.0 3.1 3.5 .2 .76 3.70 .1 .6 (3) #8 .3 2.9 3.1 2.2 1.7 1.8 (31) (102) (79) (89) (5) (19.3) (94.0) (3.5) (15) M4 (8.0) (72.4) (78) (55) (43) (45) Reversing A 2.50 4.0 3.1 3.5 .2 1.31 3.52 .2 .5 (3) #8 .9 3.0 3.1 2.2 1.7 1.8 (64) (102) (79) (89) (5) (33.2) (89.4) (5) (13) M4 (24) (76.0) (78) (55) (43) (45) Logic Level Auxiliary (Reduce Dim. ”D” .28 (7) for the D Single Auxiliaries) Line Terminals Q H F K K (1 L1, 3 L2, 5 L3) J J Standard DIN Rail M M B G B G 1.38 x .30 (35 x 7.5) (Optional Mounting) Reset Button Reset Reset .015 (.4) Button Button Deflection E L L to Reset Load Terminals A B R (2 T1, 4 T2, 6 T3) A P Control Non-reversing Starter Reversing Starter Terminal Block N C Figure 34-162. Approximate Dimensions — Inches (mm) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-254 IT. Electro-Mechanical March 2009 Dimensions Non-reversing Starters (Frames B – E) Table 34-308. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Mtg. Reset Button Terminals Size Screws Width Height Depth Depth w/ Depth added Width Height Width Height Depth Control Line Load Auxiliary w/DIN Rail AB C D E F G K L M N P Q R B1.8 5.0 2.5 3.6 .1 1.33 4.62 (3) #8 .6 3.6 2.5 1.7 1.2 .6 34 (45) (127) (63) (91) (3) (33.8) (117.3) M4 (14) (91) (63) (44) (30) (16) C 2.1 5.4 2.5 3.6 .1 1.46 5.04 (3) #8 .7 3.7 2.4 1.8 1.2 .3 (54) (138) (63) (91) (3) (37) (128) M4 (17) (93) (62) (45) (30) (8) D 3.0 5.9 3.1 4.2 .2 .94 2.87 (4) #6 x 2 .7 4.2 3.1 2.4 1.5 .6 (76) (150) (79) (107) (4) (24) (73) M3.5 x 50 (17) (106) (78) (60) (37) (14) E 4.1 8.0 3.5 4.7 — 1.33 4.13 (4) #8 x 1.5 .7 5.7 3.5 2.8 1.7 .3 (105) (203) (90) (119) (33.8) (105) M4 x 40 (17) (146) (88) (72) (42) (8) D H A Line Terminals Q F (1 L1, 3 L2, 5 L3) J Dual Auxiliary – Reduce Dim “D” .3 (7) for the Standard M Single Auxiliaries DIN Rail K G B 1.38 x .3 (D and E (35 x 7.5) Frames) (Optional Mounting) Reset Button Reset Button .015 (0.4) Deflection to Reset R Control K Terminal Block Load Terminals (B and C P L (2 T1, 4 T2, 6 T3) Frames) E N C Figure 34-163. Approximate Dimensions — Inches (mm) Non-reversing Starter (Frame F) Table 34-309. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Mtg. Reset Button Terminals Size Screws Width Length Depth Depth Width Width Height Mntg. Width Height Depth Control Line Load Load w/Logic w/Side Hole Level Auxiliary Auxiliaries to Top AB C D E F G I K L M N P Q R S F 5.7 19.4 7.0 8.2 6.7 1.75 18.3 .58 (4) 5/16 2.4 12.4 5.3 5.0 4.4 3.0 4.0 (145) (493) (178) (208) (170) (44.5) (465) (14.7) M8 (61) (315) (135) (126) (112 (75) (101) ) E D H C F Line Terminals Q K (1 L1, 3 L2, 5 L3) M Side Auxiliary Logic G B Auxiliary Reset Button Control Terminal .015 (.4) Block Deflection to Reset Load Terminals (2 T1, 6 T3) R S (4 T2) L P A N Figure 34-164. Approximate Dimensions in Inches (mm) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-255 IT. Electro-Mechanical March 2009 Dimensions Reversing Starters (Frames B – E) Table 34-310. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Mtg. Reset Button Terminals Size Screws Width Length Depth Depth w/ Width Height Mtg. Width Height Depth Control Line Load Auxiliary Hole to Top A B C D FG H K LM N P Q R 34 B3.8 5.9 2.7 3.8 3.15 5.35 .28 (3) #10 1.6 3.8 2.7 2.0 1.5 .9 (96) (149) (69) (96) (80) (136) (7) M5 (40) (97) (68) (50) (38) (22) C 4.5 5.9 2.6 3.8 3.15 5.35 .28 (3) #10 1.7 4.1 2.6 2.0 1.5 .6 (114) (149) (67) (96) (80) (136) (7) M5 (43) (104) (65) (50) (38) (16) D 6.2 7.4 3.3 4.4 5.51 6.89 .24 (3) #10 2.3 5.5 3.3 2.6 1.9 .9 (158) (188) (84) (112) (140) (175) (6) M5 (58) (139) (83) (67) (48) (22) E 8.5 9.5 3.8 4.9 7.87 9.06 .24 (3) #10 2.9 7.2 3.7 3.1 2.1 .7 (216) (242) (97) (125) (200) (230) (6) M5 (73) (182) (94) (80) (54) (17) D H K Line Terminals Q (1 L1, 3 L2, 5 L3) Dual Auxiliary – Reduce Dim “D” B G M .3 (7) for the Single Auxiliaries Reset Button .015 (0.4) Deflection to Reset Reset Load Terminals Button R (2 T1, 4 T2, 6 T3) P L Control N F Terminal Block C A Figure 34-165. Approximate Dimensions — Inches (mm) Reversing Starter (Frame F) Table 34-311. Approximate Dimensions in Inches (mm) Frame Overall Mounting Holes Req. Reset Button Terminals Size Mtg. Width Length Depth Depth w/Logic Width Width H1 Mntg. H2 Width Height Depth Control Line Load Load Screws Level Auxiliary w/Side Hole Auxiliaries to Top A B C D E F GH I K L M N P QR S F 11.8 21.0 7.0 8.2 12.8 7.82 18.3 2.19 13 (5) 5/16 5.4 12.4 5.3 5.0 4.4 3.0 4.0 (300) (533) (178) (208) (325) (199) (465) (55.5) (330) M8 (138) (315) (135) (126) (112) (75) (101) D E C F Line Terminals Q K (1 L1, 3 L2, 5 L3) H I M Side B Auxiliary Logic G Auxiliary Reset Button .015 (.4) Deflection Control Terminal to Reset Block Load Terminals (2 T1, 6 T3) R L S F (4 T2) A P N Figure 34-166. Approximate Dimensions in Inches (mm) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-256 Freedom Miniature Controls March 2009 Product Family Overview Contents Overload Relays (Bimetallic Type — C312) Description Page ■ 11 Settings — to cover .10 to 12.0 Product Family Overview Amps Product Description. . . . . . . 34-256 ■ Phase loss compensated Features . . . . . . . . . . . . . . . . 34-256 ■ Ambient temperature Standards and compensated 34 Certifications . . . . . . . . . . . 34-256 ■ Class 10 — Bimetallic type O.L. Instructional Leaflets . . . . . . 34-256 ■ Stop and test buttons included Catalog Number ■ 1NO-1NC auxiliary contacts Selection . . . . . . . . . . . . . . 34-257 included as standard Mini Contactor with Screw Pressure Plate Terminals Contactors — Non-reversing and Catalog Number CE12BNC310B Accessories Reversing Product Selection . . . . . . . . 34-258 ■ Side and front mounted auxiliary contacts Accessories ■ Identification clips Auxiliary Contacts Front ■ Surge suppressors and Side Mounted . . . . . . 34-259 ■ Reversing connection links Overload Relays. . . . . . . . . . 34-259 ID Markers, Reversing Connection Links and Standards and Certifications Surge Suppressors . . . . . . 34-260 Meet or exceed the North American and International standards: Mini Contactor Reversing Pair with Note: For more information, see Screw Pressure Plate Terminals CA03402001E. ■ UL Catalog Number CE52CNC310H ■ CSA ❑ Mini Contactors and Surge Suppressors Product Description UL File No. E19224, Category NLDX and NLDX2; CSA File No. Eaton offers a complete line of Cutler- ® LR353, Class 3211-07 Hammer Miniature Control Products that includes mini contactors (mechan- ❑ Accessories ically interlocked and non-reversing), UL File No. E19223, Category overload relays and snap-on accesso- NKCR and NKCR2; CSA File No. ries. A wide range of applications are LR353, Class 3211-07 possible, including small electrical ❑ Overload Relays motors fractional to 5 hp (480V AC). UL File No. E19223, Category Because of its compact size, the line is NKCR and NKCR2; CSA File No. best suited to be applied in light duty LR353, Class 3211-03 loads such as hoisting, packaging, ■ IEC, VDE, CE and most other material handling, heating, lighting International standards and automation systems. Instructional Leaflets Features 49097 Minicontactors, Overloads and Mini Contactors Accessories ■ Available in three different terminal configurations: ❑ Screw Pressure Plate ❑ Quick Connect ❑ Solder Pin ■ Mechanically interlocked or non-reversing ■ Panel or DIN rail mounting (35 mm) ■ Fingerproof protection ■ Low noise operation ■ AC or DC operation possible For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-257 Freedom Miniature Controls March 2009 Catalog Number Selection Catalog Number Selection Table 34-312. IEC Miniature Controls Catalog Numbering System C E 1 2 B N C 3 1 0 W 1 Coil Designations Designation Type AC Coil Voltage (Frequency 40 – 450 Hz) 34 CE - IEC Contactor 12 - Non-reversing T -24V 52 - Mechanically Interlocked W -48V A -110 – 127V 3.5 VA B -220 – 240V Power H -227V B - 4 kW (3 hp @460V AC) L -380 – 415V C - 5.5 kW (5 hp @460V AC) DC Coil Voltage R1 -12V Enclosure T1 -24V N - Open W1 -48V 3.5 Watts A1 -110 – 125V B1 -220 – 240V Connections DC — Low Power Consumption Coils B - Quick Connects T2 -24V (1.4 Watts) C - Screw Pressure Plate V2 -17 – 32V (2.4 Watts) P - Solder Pin T3 -24V (1.7 Watts with Surge Suppressor) V3 -17 – 32V (2.8 Watts with Surge Suppressor) No. of Poles 3 Poles 3 - 4 Poles 4 - No. of NO Aux. Contacts No. of NC Aux. Contacts NOTE: No renewal parts (coils, contact kits) available for the Mini Control line. 0 - None 0 - None 1 - One 1 - One CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-258 Freedom Miniature Controls March 2009 Contactors — Non-reversing and Reversing Product Selection Non-reversing/Reversing Contactors with Screw Pressure Terminals 34 Screw Pressure Plate Terminals — Screw Pressure Plate Terminals — Non-reversing Contactor Reversing Contactor � Table 34-313. Non-reversing Contactor — Screw Pressure Plate Terminals Max. IEC 947 kW Maximum UL Horsepower No. of Aux. Catalog Price U.S. $ AC-3 AC-1 Rating Power Contacts Number 1-Phase Horsepower Ratings 3-Phase Horsepower Ratings AC DC Amp Thermal AC-3 Poles Coil Coil 110/ 220/ 480/ 110/ 200/ 220/ 440/ 550/ Rating Current 400/440V 120V 240V 600V 120V 208V 240V 480V 600V (400V) (400V) 9 16 4 1/2 1 None 1 1 2 3 3 3 1NO CE12BNC310_ 9 16 4 1/2 1 None 1 1 2 3 3 3 1NC CE12BNC301_ 9 16 4 1/2 1 None 1 1 2 3 3 4 None CE12BNC400_ 12 20 5.5 3/4 1-1/2 2 1 2 3 5 5 3 1NO CE12CNC310_ 12 20 5.5 3/4 1-1/2 2 1 2 3 5 5 3 1NC CE12CNC301_ 12 20 5.5 3/4 1-1/2 2 1 2 3 5 5 4 None CE12CNC400_ � Quick Connect and Solder Pin Terminals are available. Insert a “B” into the seventh digit for Quick Connect or “P” for Solder Pin Terminal. � Table 34-314. Reversing Contactor — Screw Pressure Plate Terminals Max. IEC 947 kW Maximum UL Horsepower No. of Aux. Catalog Price U.S. $ AC-3 AC-1 Rating Power Contacts Number 1-Phase Horsepower Ratings 3-Phase Horsepower Ratings AC DC Amp Thermal AC-3 Poles Coil Coil 110/ 220/ 480/ 110/ 200/ 220/ 440/ 550/ Rating Current 400/440V 120V 240V 600V 120V 208V 240V 480V 600V (400V) (400V) 9 16 4 1/2 1 None 1 1 2 3 3 3 1NO CE52BNC310_ 9 16 4 1/2 1 None 1 1 2 3 3 3 1NC CE52BNC301_ 12 20 5.5 3/4 1-1/2 2 1 2 3 5 5 3 1NO CE52CNC310_ 12 20 5.5 3/4 1-1/2 2 1 2 3 5 5 3 1NC CE52CNC301_ � Screw pressure plate terminal contactors are supplied standard with reversing connection links included. Quick Connect and Solder Pin Terminals are available. Insert a “B” into the seventh digit for Quick Connect or “P” for Solder Pin Terminal. Table 34-315. AC Coil Selection Table Table 34-316. DC Coil Selection Table Coil Voltage Frequency Suffix Coil Voltage Suffix � 40 – 450 Hz Code Code 24 3.5 VA T 12 3.5 Watts R1 48 3.5 VA W 24 3.5 Watts T1 110 – 127 3.5 VA A 48 3.5 Watts W1 220 – 240 3.5 VA B 110 – 125 3.5 Watts A1 277 3.5 VA H 220 – 240 3.5 Watts B1 380 – 415 3.5 VA L � DC Low Power Consumption Coils: Non-reversing Mini Contactors � AC coils have an integrated protective circuit-rectifier bridge and 24 (1.4 Watts) T2 varistor included. 17 – 32 (2.4 Watts) V2 24 (1.7 Watts with Surge Suppressor) T3 17 – 32 (2.8 Watts with Surge Suppressor) V3 � Auxiliary contacts can not be used with Low Power Consumption DC Coils Suffix designations: T2, V2, T3 and V3. Table 34-317. Price Adder for Low Wattage DC Coils Devices Suffix Designations Adder U.S. $ 4 kW T2 & V2 T3 & V3 5 kW T2 & V2 T3 & V3 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-259 Freedom Miniature Controls March 2009 Accessories Auxiliary Contacts Front and Side Mounted Overload Relays A total of six auxiliary contacts are available to be used with the mini control line. Front mounted auxiliary contacts are available in three contact configurations (1NO-1NC, 2NO and 2NC) and can be screw mounted to non-reversing and reversing contactors with screw pressure plate terminals only. 34 Side mounted auxiliary contacts are available for the miniature control product line in three terminal versions: screw pressure plate, quick connect and solder pin. The side mounted auxiliary is mounted to the left side of non- reversing contactors without tools. Only one side mounted auxiliary can be mounted on these products. Overload Relay Table 34-318. Front Mount Auxiliary Contacts for Screw Pressure Plate Table 34-320. Bimetallic Overload Relay — Class 10 Terminals — Only Mini Contactor and Control Relay Motor FLA Max. Fuse — Wt. Catalog Price Add-On Auxiliary Catalog Price in Amperes Type gL A Lbs. (kg) Number U.S. $ Contacts Configuration Number U.S. $ .10 – .16 .5 .154 (.070) C312AN3A 1NO-1NC C320MCF11 .16 – .24 1.0 .154 (.070) C312AN3B 2NO C320MCF20 .24 – .40 2.0 .154 (.070) C312AN3C 2NC C320MCF02 .40 – .60 2.0 .154 (.070) C312AN3D .60 – 1.00 4.0 .154 (.070) C312AN3E Table 34-319. Side Mount Auxiliary Contacts for Screw Pressure Plate, 1.00 – 1.60 6.0 .154 (.070) C312AN3F Quick Connect, Solder Pin Terminals and Control Relays 1.60 – 2.40 6.0 .154 (.070) C312AN3G Terminal Type Add-On Catalog Price 2.40 – 4.0 10.0 .154 (.070) C312AN3H Contactor/Control Relay Auxiliary Number U.S. $ 4.0 – 6.0 10.0 .154 (.070) C312AN3J Contacts 6.0 – 9.0 10.0 .154 (.070) C312AN3K Configuration 9.0 – 12.0 20.0 .154 (.070) C312AN3L Screw Pressure Plate 1NO-1NC C320MCS11 Note: Overload relays to be used with Pressure Plate Terminal type Mini Contactors only. Quick Connect 1NO-1NC C320MBS11 Solder Pin 1NO-1NC C320MPS11 Thermal Overload Relay C312 — Technical Data Application Notes Conformity to Standards ■ Side mounted auxiliary contacts can not be used simulta- ■ IEC 947-4-1, 947-5-1, CE neously with front mounted auxiliary contacts. ■ UL 508, CSA 22.2 ■ Auxiliary contacts can not be used with low power DC Coil Suffix designations T2, T3, V2 or V3. Thermal (Bimetallic) Overload Relay, C312 OL Relay ■ Side mounted auxiliary contacts can not be used with ■ Insulation Voltage (U ): 690V AC i mechanically interlocked contactors. ■ Rated Operational Voltage (U ): 690V AC e ■ Auxiliary contacts used with devices having screw pres- ■ Ambient Temperature: -13° to 122°F (-25° to +50°C) sure plate terminals are UL Listed and side mounted temperature compensated auxiliary contacts used with devices having quick connect ■ Storage: -40° to 158°F (-40° to +70°C) or solder pin terminals are UL Recognized. ■ Impulse Withstand Voltage (U ): 6 kV imp ■ Climatic Resistance — ❑ Acc. to DIN 50 017 ❑ Acc. to UTE C 63 – 100: IEC 68-2-3, IEC 68-2-30 ■ Mounting Position: ± 30 from vertical position, not horizontal, not upside down, 5 mm side by side mounting distance ■ Switching Frequency with Avoidance of Nuisance Trippings — max. ops./h: 15 ■ ≤ 40% ED — max. ops./h: 60 (if 6X in startup time ≤1 s) ■ Overvoltage Category/Pollution Degree: III/3 ■ Safe Isolation to IEC 536: 300V AC ■ Conventional Free Air Thermal Current (I ): 6.0A th Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-260 Freedom Miniature Controls March 2009 Accessories and Terminal Markings Identification Markers, Reversing Connection Links and Surge Suppressors 34 Reversing Connection Links Surge Suppressors Table 34-321. Other Accessories Description Catalog Price Number U.S. $ Identification Markers C320MCM1 Surge Suppressors to use with Screw Pressure Plate Control Relays and Mini Contactors: Surge Suppressor 24 – 60V DC C320MSS1 Surge Suppressor 50 – 250V DC C320MSS2 Surge Suppressor 200 – 420V DC C320MSS3 Surge Suppressors to use with Quick Connect Control Relays and Mini Contactors: Surge Suppressor 24 – 60V DC C320MSS4 Surge Suppressor 50 – 250V DC C320MSS5 Surge Suppressor 200 – 420V DC C320MSS6 � Reversing Connection Links (2 Pieces) C320MCR1 � To be used with mechanically interlocked screw pressure plate terminal contactors. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-261 Freedom March 2009 Product Family Overview 34 AE17 Fixed Heater IEC Starter Size B IEC AE17KNS0AFE IEC AE17DNS0AFE IEC Size K, 50 hp/460V IEC Size D, 10 hp/460V Product Description Features Eaton’s electrical business has been Freedom IEC Features AE17 Fixed Heater supplying quality Industrial Control IEC Starter Size K Freedom IEC contactors and starters products for more than 100 years — are designed to IEC standards and ® the Cutler-Hammer Freedom Series comply with the International Stan- line of Contactors and Starters con- dard IEC 947-4-1. IEC products are a tinue in this tradition. The IEC Freedom perfect choice when electrical and Series Contactors and Starters feature a mechanical application parameters are compact space-saving design, using known. They are typically smaller in Series B state-of-the-art technology and the lat- size and provide higher ratings in a Heater Pack est in high strength, impact and tem- smaller package. They are available in perature resistant insulating materials. 22 sizes to match the contactor to the Eaton is the only manufacturer to offer application. IEC Starters with two different over- Standards and Certifications ■ Complies with IEC 947-4-1, EN, load options: Fixed Bimetallic Over- CENELEC, UL and CSA standards. ■ Standard: Designed to meet or load and Interchangeable Heater ■ 22 Sizes of contactors through exceed UL, NEMA, IEC, CSA, VDE Overload with Heater Packs. Contac- 900 hp. and BS tors and Overloads can also be ordered separately or as completely ■ DIN rail mountable through 20 hp. ■ UL Listed: UL File #E1491, Guide assembled starters with either over- #NLDX — Open ■ Adjustable bimetal overload relays load relay option. — fixed or interchangeable heater. ■ CSA Certified: CSA File #LR353, Class #321104 Open ■ Available in Open and NEMA 1, 3R, 4/4X and 12 enclosures. ■ IEC: Sizes A – S, IEC 947-4-1; Sizes T – Z, IEC 158 (IEC 947 Pending) Certified Type 2 Coordination Eaton’s Cutler-Hammer Freedom Series IEC starters are now UL Certi- fied to achieve IEC 947 Type 2 coordi- nation against 100,000A short circuit fault currents. Any brand of properly selected fuse can be used. Type 2 coordination means that the starter will be suitable for further use following a short circuit fault. CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-262 Freedom March 2009 Contactors — Non-reversing and Reversing ■ IP20 finger protection shields Contents Product Description available. Description Page ■ Contactor and terminal markings Non-reversing conform to CENELEC EN50011. Product Family Overview Contactors are most commonly used ■ Holding circuit contact(s) supplied Product Description. . . . . . . 34-261 to switch motor loads in applications as standard: Features . . . . . . . . . . . . . . . . 34-261 where running over current protection ❑ Sizes A – N have a NO auxiliary is either not required or is provided Standards and contact block mounted on right 34 separately. Contactors consist of a Certifications . . . . . . . . . . . 34-261 hand side (on Sizes A – C, contact magnetically actuated switch which occupies 4th power pole position Contactors — Non-reversing can be remotely operated by a push- — no increase in width). and Reversing button station or pilot device such as a ❑ Sizes P – S have a NO-NC contact Product Description. . . . . . . 34-262 proximity switch, limit switch, float block mounted on the left hand side. switch, auxiliary contacts, etc. Features . . . . . . . . . . . . . . . . 34-262 ❑ Sizes T – Z have a 2NO-2NC con- Product Selection — tact block mounted on the top left Reversing 3-Pole Contactors . . . . . . . 34-263 between arc chutes. Reversing contactors are used prima- Product Selection — ■ Lugs supplied standard on Sizes rily for reversing single- or three-phase 2-, 4- and 5-Pole A – S. On Sizes T – Z, lugs must be motors in applications where running Contactors . . . . . . . . . . . . . 34-264 ordered separately. over current protection is either not Accessories . . . . . . . . . . . . . . . . 34-277 required or is provided separately. Reversing They consist of two contactors mechan- Auxiliary Contacts . . . . . . . . 34-277 ically and electrically interlocked to ■ Highest horsepower rating in a com- DC Magnet Coils . . . . . . . . . 34-279 prevent line shorts and energization of pact, space-saving design, 45 mm Renewal Parts. . . . . . . . . . . . . . 34-284 both contactors simultaneously. frame rated maximum 20 hp, 65 mm frame rated maximum 50 hp and Note: For more information, see 90 mm frame rated maximum 75 hp Features CA03402001E. at 460V. If larger devices are required, order components. ■ EN60947-4-1 IEC 947-4-1 Compli- ■ 45 mm open type reversing contac- ance — new International Standard tors, Sizes A – F, have DIN rail or for low voltage switchgear and con- panel mounting capability. DIN rail trol devices. release mechanism conveniently ■ Long life twin break, silver cadmium located on line side of contactor. A oxide contacts — provide excellent steel mounting plate is optional. conductivity and superior resistance ■ 65 mm reversing contactors, Sizes to welding and arc erosion. G – K and 90 mm Sizes L – N are ■ Designed to 2,000,000 electrical and supplied with steel mounting plate 20,000,000 mechanical operations at as standard. maximum hp ratings through 20 hp ■ Sizes A – K have a wired NC top at 460V. Adequate for most general mounted electrical interlock on each duty control applications. IEC Size B contactor. Sizes L – N have one NO- Cat. No. CE15BNS3AB NC side mounted electrical inter- Non-reversing lock on each contactor. ■ UL listed and CSA certified. ■ Highest horsepower rating in a com- pact, space-saving design, 45 mm frame rated maximum 20 hp at 460V, 65 mm frame rated maximum 50 hp, 90 mm frame rated 100 hp, 180 mm frame rated 200 hp, 220 mm frame rated 350 hp, 280 mm frame rated 600 hp, and 334 mm frame rated 900 hp. ■ 45 mm open contactors, Sizes A – F, have DIN rail or universal base IEC Size D mounting, 65 mm open contactors Cat. No. CE55DN3AB have molded feet for panel mount- ing, and 90 mm to 334 mm have steel mounting plates (optional on smaller sizes). ■ DIN rail release mechanism conve- niently located on line side of contactor. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-263 Freedom March 2009 Contactors — Non-reversing and Reversing Product Selection — 3-Pole Contactors When Ordering Specify ■ Select required contactor by Catalog Number and replace the magnet coil alpha designation in the Catalog 34 Number (_) with the proper Code Suffix from Tables 34-324 and 34- 326, on Page 34-265. ■ For Sizes A – K, the magnet coil alpha designation is the second-to- last digit of the Catalog Number. IEC Size E IEC Size N Example: for a 240V/60 Hz coil, order Cat. No. CE15ENS3AB Cat. No. CE15NN3A CE15ANS3BB. Table 34-322. Type CE15/CE55 IEC Product Selection — 3-Pole Contactors Max. IEC 947 Maximum kW Rating Maximum UL Horsepower 3-Pole — 3-Pole — �� � UL AC-1 Non-reversing Reversing AC-3 Thermal 3-Phase 1-Phase 3-Phase Catalog Price Catalog Price Amp. Current Number U.S. $ Number U.S. $ 220V 380V 415/ 500/ 660V 115V 230V 200V 230V 460V 575V Rating 600V 440V 550V 600V AC 7 20 1.1 2.2 2.2 4 1.5 1/4 1/2 1-1/2 1-1/2 3 5 CE15ANS3_B CE55AN3_B 10 20 1.5 4 4 5.5 2.2 1/2 1 2 2 5 7-1/2 CE15BNS3_B CE55BN3_B 12 20 2.2 5.5 5.5 7.5 4 1/2 2 3 3 7-1/2 10 CE15CNS3_B CE55CN3_B 18 32 4 7.5 7.5 11 5.5 1 3 5 5 10 15 CE15DNS3_B CE55DN3_B 25 32 5.5 11 11 15 7.5 2 3 5 7-1/2 15 20 CE15ENS3_B CE55EN3_B 32 32 7.5 15 15 18.5 10 2 5 7-1/2 10 20 25 CE15FNS3_B CE55FN3_B 37 50 — 18.5 18.5 22 11 3 5 7-1/2 10 25 30 CE15GNS3_B CE55GN3_B 44 60 11 22 22 30 15 3 7-1/2 10 15 30 40 CE15HNS3_B CE55HN3_B 60 75 15 30 30 30 18.5 5 10 15 20 40 40 CE15JNS3_B CE55JN3_B 73 80 18.5 37 37 37 22 5 10 20 25 50 50 CE15KNS3_B CE55KN3_B 85 100 22 45 45 55 37 7-1/2 10 25 30 60 75 CE15LN3_ CE55LN3_ 105 135 30 55 55 75 45 10 10 30 40 75 100 CE15MN3_ CE55MN3_ 140 175 37 75 75 90 45 10 10 40 50 100 125 CE15NN3_ CE55NN3_ 170 185 45 90 90 90 45 — — 50 60 125 125 CE15PN3_ — 200 220 55 110 110 110 55 — — 60 75 150 150 CE15RN3_ — 300 315 90 160 160 160 75 — — 75 100 200 200 CE15SN3_ — 420 600 129 220 240 300 300 — — 125 125 250 250 CE15TN3_80 — 520 760 160 280 315 375 375 — — 150 150 350 350 CE15UN3_80 — 550 1000 220 375 — 500 500 — — 150 200 400 400 CE15VN3_80 — 700 1000 220 375 — 500 500 — — 200 250 500 500 CE15WN3_80 — 810 1100 270 475 — 600 600 — — 250 300 600 600 CE15XN3_80 — 1215 1350 380 650 — 840 840 — — 450 450 900 900 CE15ZN3_80 — � IEC Sizes A – N are supplied with a NO auxiliary contact. On IEC Sizes A – C, the 4th power pole position is used as the auxiliary contact and adds no additional width. Open type Sizes A – K can be ordered with a top mounted auxiliary contact instead of a side mounted contact. To order, change the 7th digit of the listed Catalog Number from “S” to “T” . Example: CE15ANT3AB. On open type Sizes A – K, if the NO auxiliary contact is not required, drop the “S” from the listed Catalog Number. � Auxiliary contacts: Sizes P – S have 1NO-1NC, Sizes T – X have 2NO-2NC, Size Z has 2NO-1NC. Sizes T – Z are supplied without lugs — order appropriate lug kits from Table 34-325 on Page 34-265. � Sizes A – K IEC contactors do not include holding circuit contacts. For factory installed NO auxiliary contacts, insert “S” (side mounted) or “T” (top mounted) after 6th digit of listed Catalog Number. Example: Change CE55AN3AB to CE55ANS3AB. For “T” , top mounted NC contact blocks are replaced with NO-NC blocks — for “S” , they are replaced with NO-NC side mounted blocks. Accessories . . . . . . . . . . . . . Pages 34-277 – 34-283 Discount Symbol . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-264 Freedom March 2009 Contactors — Non-reversing and Reversing Product Selection — 2-, 4- and 5-Pole Contactors When Ordering Specify ■ Select required contactor by Catalog Number and replace the magnet coil alpha designation in the Catalog 34 Number (_) with the proper Code Suffix from the adjacent table. ■ For Sizes A – K, the magnet coil IEC Size G alpha designation is the second-to- 4-Pole Contactor last digit of the Catalog Number. Cat. No. CE15GN4AB Example: for a 240V/60 Hz coil, order CE15ANS3BB. ■ For DC Magnet Coils, see Accessories, Page 34-279. Table 34-323. Type CE15 IEC Product Selection — 2-, 4- and 5-Pole Contactors — Non-reversing Max. UL AC-3 IEC 947 AC-1 Maximum kW Rating Maximum UL Horsepower Catalog Price Ampere Thermal Number U.S. $ 3-Phase 1-Phase 3-Phase Rating Current 220V 380V 415/ 500/ 660V 115V 230V 200V 230V 460V 575V 600V AC 600V 440V 550V � 2-Pole 7 20 1.1 2.2 2.2 4 1.5 1/4 1/2 1-1/2 1-1/2 3 5 CE15ANS2_B 10 20 1.5 4 4 5.5 2.2 1/2 1 2 2 5 7-1/2 CE15BNS2_B 12 20 2.2 5.5 5.5 7.5 4 1/2 2 3 3 7-1/2 10 CE15CNS2_B 18 32 4 7.5 7.5 11 5.5 1 3 5 5 10 15 CE15DNS2_B 25 32 5.5 11 11 15 7.5 2 3 5 7-1/2 15 20 CE15ENS2_B 32 32 7.5 15 15 18.5 10 2 5 7-1/2 10 20 25 CE15FNS2_B 37 50 — 18.5 18.5 22 11 3 5 7-1/2 10 25 30 CE15GNS2_B 44 60 11 22 22 30 15 3 7-1/2 10 15 30 40 CE15HNS2_B 60 75 15 30 30 30 18.5 5 10 15 20 40 40 CE15JNS2_B 73 80 18.5 37 37 37 22 5 10 20 25 50 50 CE15KNS2_B 85 100 22 45 45 55 37 7-1/2 10 25 30 60 75 CE15LN2_ 105 135 30 55 55 75 45 10 10 30 40 75 100 CE15MN2_ 140 175 37 75 75 90 45 10 10 40 50 100 125 CE15NN2_ 4-Pole 7 20 1.1 2.2 2.2 4 1.5 1/4 1/2 1-1/2 1-1/2 3 5 CE15AN4_B 10 20 1.5 4 4 5.5 2.2 1/2 1 2 2 5 7-1/2 CE15BN4_B 12 20 2.2 5.5 5.5 7.5 4 1/2 2 3 3 7-1/2 10 CE15CN4_B 18 32 4 7.5 7.5 11 5.5 1 3 5 5 10 15 — 25 32 5.5 11 11 15 7.5 2 3 5 7-1/2 15 20 — 32 32 7.5 15 15 18.5 10 2 5 7-1/2 10 20 25 — 37 50 — 18.5 18.5 22 11 3 5 7-1/2 10 25 30 CE15GN4_B 44 60 11 22 22 30 15 3 7-1/2 10 15 30 40 CE15HN4_B 60 75 15 30 30 30 18.5 5 10 15 20 40 40 CE15JN4_B 73 80 18.5 37 37 37 22 5 10 20 25 50 50 — 5-Pole 32 32 7.5 15 15 18.5 10 2 5 7-1/2 10 20 25 — 37 50 — 18.5 18.5 22 11 3 5 7-1/2 10 25 30 CE15GN5_B 44 60 11 22 22 30 15 3 7-1/2 10 15 30 40 CE15HN5_B 60 75 15 30 30 30 18.5 5 10 15 20 40 40 CE15JN5_B 73 80 18.5 37 37 37 22 5 10 20 25 50 50 — � Sizes A – N 2-pole contactors are supplied with a NO auxiliary contact. On Sizes A – C, the 4th power pole is used as the auxiliary contact and adds no additional width. Open type Sizes A – K can be ordered with a top mounted auxiliary contact instead of a side mounted contact. To order, change the “S” to a “T”. For DC Magnet Coils, see Accessories, Page 34-279. Accessories . . . . . . . . . . . . . Pages 34-277 – 34-283 Discount Symbol . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-265 Freedom March 2009 Contactors — Non-reversing and Reversing Table 34-324. AC Coil Suffixes Table 34-325. Line/Load Lug Kits — IEC Sizes T – Z Only Coil Volts and Hertz Code Suffix Lugs come standard on all contactors except 120/60 or 110/50 A sizes T – Z. If lugs are required, order sepa- 240/60 or 220/50 B rately from below. Each kit consists of three 480/60 or 440/50 C line and three load side lugs and hardware. 600/60 or 550/50 D Contactor Cable Catalog Price 208/60 E Size Range Number U.S. $ 277/60 H 34 � 208-240/60 J T (2) #2/0 – C325KAL15 240/50 K 600 kcmil 380-415/50 L U (2) #2/0 – C325KAL16 550/50 N 600 kcmil 380/60 P V – W (2) #3/0 – C325KAL17 � 24/60, 24/50 T 750 kcmil 24/50 U X (3) #3/0 – C325KAL18 32/50 V 750 kcmil 48/60 W Z (4) #1/0 – C325KAL19 750 kcmil 48/50 Y � IEC Sizes A – F only. � IEC Sizes A – F only. Sizes G – V are 24/60 only. Table 34-326. DC Coil Suffixes Contactor or Volts NCI Code Suffix Starter Size — IEC Interlock Non-reversing A – F 12 C320KGD1 R1 24 C320KGD1 T1 48 C320KGD1 W1 120 C320KGD1 A1 � A – F 12 C320KGD2 R4 � 24 C320KGD2 T4 � 48 C320KGD2 W4 � 120 C320KGD2 A4 G – K 12 C320KGD5 R4 24 C320KGD5 T4 48 C320KGD5 W4 120 C320KGD5 A4 L – N 12 C320KGD3 R1 24 C320KGD3 T1 48 C320KGD3 W1 120 C320KGD3 A1 P – S 24 C320KGD3 T1B 48 C320KGD3 W1B 120 C320KGD3 A1B 240 C320KGD3 B1B Reversing � A – F 12 (2) C320KGD1 R1 � 24 (2) C320KGD1 T1 � 48 (2) C320KGD1 W1 � 120 (2) C320KGD1 A1 � G – K 12 (2) C320KGD3 R1 � 24 (2) C320KGD3 T1 � 48 (2) C320KGD3 W1 � 120 (2) C320KGD3 A1 � These kits are supplied with a NO/NCI side mounted auxiliary contact in place of the NCI contact. � Factory installed DC coils on IEC contactors and starters include a NC top mounted auxiliary contact on each contactor for electrical interlocking. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-266 Freedom March 2009 Starters — Fixed Heater Contents Product Description Description Page Non-reversing Reversing Product Family Overview ® Eaton’s Cutler-Hammer Fixed Heater Three-phase, full voltage magnetic Product Description. . . . . . . 34-261 Starters utilize a Class 10 Bimetallic starters are used primarily for revers- Features . . . . . . . . . . . . . . . . 34-261 Overload Relay and are available for ing of 3-phase squirrel cage motors. 3-phase motor applications from frac- They consist of two contactors and a Standards and 34 tional horsepower motors up to 900 hp single overload relay assembled Certifications . . . . . . . . . . . 34-261 at 480V. together. The contactors are mechani- Fixed Heater Starters cally and electrically interlocked to pre- Product Description. . . . . . . 34-266 vent line shorts and energization of both contactors simultaneously. Features . . . . . . . . . . . . . . . . 34-266 Product Selection . . . . . . . . 34-267 Features Accessories . . . . . . . . . . . . . . . . 34-277 Auxiliary Contacts . . . . . . . . 34-277 ■ EN60947-4-1 IEC 947-1 Compliance Non-reversing — new International Standard for DC Magnet Coils . . . . . . . . . 34-279 ■ Highest horsepower rating in com- low voltage switchgear and control Renewal Parts. . . . . . . . . . . . . . 34-284 pact, space-saving designs. 45 mm devices. frame rated maximum 20 hp at ■ UL listed and CSA certified. Note: For more information, see 460V, 65 mm frame rated maximum ■ C316 Bimetallic Ambient Compen- CA03402001E. 50 hp, 90 mm frame rated maximum sated Overload Relays — available 100 hp and 180 mm frame rated in three basic sizes covering maximum 200 hp. applications up to 200 hp (150 hp ■ NO side mounted auxiliary contact Reversing) — reducing number of supplied as standard on Sizes A – N. different contactor/overload relay Sizes P, R and S have NO-NC. combinations that have to be ■ 45 mm open type starters, Sizes stocked. A – F, have DIN rail or universal base ■ These overload relays feature: mounting. A steel mounting plate is ❑ Direct heated bimetal elements — optional. Sizes G – S supplied with Class 10. steel mounting plate as standard. ❑ Single-phase and phase unbal- ■ Four basic starter frame widths — ance sensitivity. 45 mm, 65 mm, 90 mm and 180 mm ❑ Ambient temperature — simplifying panel layout. compensated. ■ 45 mm DIN rail release mechanism IEC Size D Cat. No. AE17DNS0AFE ❑ Adjustable trip current. conveniently located on line side of starter. ❑ Overload trip indication. ❑ Contact test lever. Reversing ❑ Manual/automatic reset. ■ Highest horsepower rating in com- ❑ Electrically isolated NO-NC pact, space-saving designs. 45 mm contacts. frame rated maximum 20 hp at 460V, 65 mm frame rated maximum ■ Long life twin break, silver cadmium 50 hp at 460V, and 90 mm frame oxide contacts — provide excellent rated a maximum 100 hp at 460V. conductivity and superior resistance to welding and arc erosion. ■ 65 mm reversing starters, Sizes G – K and 90 mm reversing starters ■ Designed to 2,000,000 electrical IEC Size C Sizes L – N are supplied with steel operations and 20,000,000 mechani- Cat. No. AE57CN0AFE mounting plate as standard. cal operations through 20 hp at 460V. Adequate for most general ■ Sizes A – K have a wired NC top duty motor control applications. mounted electrical interlock on each contactor. Sizes L – N have one NO- NC side mounted electrical inter- lock on each contactor. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-267 Freedom March 2009 Starters — Fixed Heater Product Selection When Ordering Specify ■ Select required starter by Catalog Number and replace the magnet coil alpha designation in the Catalog Number (_) with the proper Suffixes from the tables on Page 34-268. 34 First, select the Magnet Coil Suffix and then add the two digit Overload Relay Suffix code. ■ Example: for a Size A starter for 120V/60 Hz and full load current is 2.0A, order AE17ANS0AFH. IEC Size K IEC Size E ■ For DC Magnet Coils, see Cat. No. AE17KNS0AKB Cat. No. AE57EN0AFM Accessories, Page 34-279. Table 34-327. Type AE17/AE57 Starters — Fixed Heater Overload Relay — 3-Pole Max. UL AC-3 IEC 947 AC-1 Maximum kW Rating Maximum UL Horsepower Catalog Price � Ampere Thermal Number U.S. $ 3-Phase 1-Phase 3-Phase Rating Current 220V 380V 415/440V 500/550V 660V 115V 230V 208V 240V 480V 600V 600V �� Non-reversing 1-1/2 3 5 AE17ANS0_ 7 20 1.1 2.2 2.2 4 1.5 1/4 1/2 1-1/2 10 20 1.5 4 4 5.5 2.2 1/2 1 2 2 5 7-1/2 AE17BNS0_ 3 7-1/2 10 AE17CNS0_ 12 20 2.2 5.5 5.5 7.5 4 1/2 2 3 18 32 4 7.5 7.5 11 5.5 1 3 5 5 10 15 AE17DNS0_ 5 7-1/2 15 20 AE17ENS0_ 25 32 5.5 11 11 15 7.5 2 3 32 32 7.5 15 15 18.5 10 2 5 7-1/2 10 20 25 AE17FNS0_ 37 50 — 18.5 18.5 22 11 3 5 7-1/2 10 25 30 AE17GNS0_ 44 60 11 22 22 30 15 3 7-1/2 10 15 30 40 AE17HNS0_ 60 75 15 30 30 30 18.5 5 10 15 20 40 40 AE17JNS0_ 73 80 18.5 37 37 37 22 5 10 20 25 50 50 AE17KNS0_ 85 100 22 45 45 55 37 7-1/2 10 25 30 60 75 AE17LN0_ 105 135 30 55 55 75 45 10 10 30 40 75 100 AE17MN0_ 140 175 37 75 75 90 45 10 10 40 50 100 125 AE17NN0_ 170 185 45 90 90 90 45 — — 50 60 125 125 AE17PN0_ 200 220 55 110 110 110 55 — — 60 75 150 150 AE17RN0_ 300 315 90 160 160 160 75 — — 75 100 200 200 AE17SN0_ 300 300 — — 125 125 250 250 AE17TN0_ 420 600 129 220 240 550 760 160 280 315 375 375 — — 150 150 350 350 AE17UN0_ 500 500 — — 150 200 400 400 AE17VN0_ 630 1000 220 375 — 700 1000 220 375 — 500 500 — — 200 250 500 500 AE17WN0_ — 600 600 — — 250 300 600 600 AE17XN0_ 860 1100 270 475 1215 1350 380 650 — — 840 — — 450 450 900 900 AE17ZN0_ � Reversing 7 20 1.1 2.2 2.2 4 1.5 1/4 1/2 1-1/2 1-1/2 3 5 AE57AN0_ 2 5 7-1/2 AE57BN0_ 10 20 1.5 4 4 5.5 2.2 1/2 1 2 12 20 2.2 5.5 5.5 7.5 4 1/2 2 3 3 7-1/2 10 AE57CN0_ 5 5 10 15 AE57DN0_ 18 32 4 7.5 7.5 11 5.5 1 3 25 32 5.5 11 11 15 7.5 2 3 5 7-1/2 15 20 AE57EN0_ 32 32 7.5 15 15 18.5 10 2 5 7-1/2 10 20 25 AE57FN0_ 37 50 — 18.5 18.5 22 11 3 5 7-1/2 10 25 30 AE57GN0_ 44 60 11 22 22 30 15 3 7-1/2 10 15 30 40 AE57HN0_ 60 75 15 30 30 30 18.5 5 10 15 20 40 40 AE57JN0_ 73 80 18.5 37 37 37 22 5 10 20 25 50 50 AE57KN0_ 85 100 22 45 45 55 37 7-1/2 10 25 30 60 75 AE57LN0_ 105 135 30 55 55 75 45 10 10 30 40 75 100 AE57MN0_ 140 175 37 75 75 90 45 10 10 40 50 100 125 AE57NN0_ � Underscore (_) indicates Magnet Coil Suffix and Overload Relay Suffix code. � IEC Sizes A – K are supplied with a NO auxiliary contact. On IEC Sizes A – C, the 4th power pole position is used as the auxiliary contact and adds no additional width. Open type sizes A – K can be ordered with a top mounted auxiliary contact instead of a side mounted contact. To order, change the 7th digit of the listed Catalog Number from “S” to “T” . Example: AE17ANT0AFC. On open type sizes A – K, if the NO auxiliary contact is not required, drop the “S” from the listed Catalog Number. Example: AE17AN0AFC. IEC Sizes L – N open are supplied with a NO side mounted auxiliary contact. On IEC Sizes P – S, a NO-NC side mounted is standard. Sizes T – X have 2NO-2NC, Size Z has 2NO-1NC. � Starters include fixed heater overload relay. AE17 is only an ordering number. Assembled starter consists of individually marked CE15 contactor and C316 overload relay. � Sizes A – K IEC starters do not include holding circuit contacts. For factory installed NO auxiliary contacts, insert “S” (side mounted) or “T” (top mounted) after 6th digit of listed Catalog Number. Example: Change AE57AN0AFC to AE57ANS0AFC. For “T” , top mounted NC contact blocks are replaced with NO-NC blocks — for “S” , they are replaced with NO-NC side mounted blocks. Accessories . . . . . . . . . . . . . Pages 34-277 – 34-283 Discount Symbol . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-268 Freedom March 2009 Starters — Fixed Heater Table 34-328. Maximum Horsepower Rating of Starters for 380V 50 Hz Application IEC Size A B C D E FG H JK LM N P R S hp 35510 10 15 20 25 30 40 50 60 75 100 125 150 Table 34-329. AC Coil Suffixes Table 34-330. Fixed Heater Overload Relay � Suffix Codes Coil Volts and Hertz Code Suffix Motor Full Suffix Motor Full Suffix 120/60 or 110/50 A Load Letter Load Letter 34 240/60 or 220/50 B Amperes Amperes 480/60 or 440/50 C Sizes AE17A – AE17F 600/60 or 550/50 D 208/60 E .25 – .40 FC 3.5 – 5.0 FL .40 – .63 FD 4.5 – 6.5 FM 277/60 H .63 – 1.0 FE 6.0 – 8.5 FN � 208-240/60 J 1.0 – 1.4 FF 7.5 – 11 FP 240/50 K 1.3 – 1.8 FG 10 – 14 FQ 380-415/50 L 550/50 N 1.7 – 2.4 FH 13 – 19 FR 2.2 – 3.1 FJ 18 – 24 FS � 24/60, 24/50 T 2.8 – 4.0 FK 24 – 32 FT 24/50 U 32/50 V Sizes AE17G – AE17K 48/60 W 18 – 25 KA 36 – 52 KD 48/50 Y 22 – 32 KB 45 – 63 KE � IEC Sizes A – F only. 29 – 42 KC 60 – 80 KF � IEC Sizes A – F only. Sizes G – V are Sizes AE17L – AE17N 24/60 only. 65 – 90 PA 110 – 150 PD 80 – 100 PB 130 – 175 PE For DC Magnet Coils, see Accessories, 100 – 135 PC — — Page 34-279. Sizes AE17P – AE17S with 300/5 CT 60 – 84 FF 132 – 186 FJ 78 – 108 FG 168 – 240 FK 102 – 144 FH 210 – 300 FL Sizes AE17T – AE17V with 600/5 CT 120 – 168 FF 264 – 372 FJ 156 – 216 FG 336 – 480 FK 204 – 288 FH 420 – 600 FL Sizes AE17W – AE17X with 1000/5 CT 200 – 280 FF 440 – 620 FJ 260 – 360 FG 560 – 800 FK 340 – 480 FH 700 – 1000 FL Size AE17Z with 1500/5 CT 300 – 420 FH 660 – 930 FJ 390 – 540 FG 840 – 1200 FK 510 – 720 FH 1050 – 1500 FL � Overload relay range can not exceed contac- tor ampere rating. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-269 Freedom March 2009 Relays — Fixed Heater Overload ■ Ambient temperature compensated. Contents Features ■ Adjustable trip current, overload trip Description Page ■ EN60947-4-1 IEC 947-4-1 Compliance indication. — the International Standard for low Product Family Overview ■ NO-NC electrically isolated contacts, voltage switchgear and control contact test lever. Product Description . . . . . . 34-261 devices. ■ Manual/automatic reset. Features . . . . . . . . . . . . . . . 34-261 ■ Direct heated bimetal elements. ■ DIN rail and panel mounting Standards and ■ Class 10 trip characteristics through 34 adapter. Certifications . . . . . . . . . . 34-261 200 amperes and Class 30 on 400 Fixed Heater Overload Relays and 850 ampere relays. Standards and Certifications Product Description . . . . . . 34-269 ■ Single-phase and phase unbalance sensitive. Features . . . . . . . . . . . . . . . 34-269 ■ UL listed — File E130332 Standards and ■ CSA certified — File LR15332M94 Certifications . . . . . . . . . . 34-269 Accessories. . . . . . . . . . . . . 34-269 Table 34-331. Overload Configurations — C316 Overload Product Selection. . . . . . . . 34-269 Size Mounting Arrangements Accessories . . . . . . . . . . . . . . . 34-277 Overload Contactor Auxiliary Contacts . . . . . . . 34-277 F A – F Connecting links are provided for close coupling. DC Magnet Coils . . . . . . . . 34-279 For independent mounting, an accessory kit C306TB1 is required. Renewal Parts . . . . . . . . . . . . . 34-284 K G – K Connecting links are provided for close coupling. For independent mounting, an accessory kit Note: For more information, see C316TB1 is required which replaces the connectors CA03402001E. and repositions the calibration marks with an additional label. P L – N Connecting links are provided for close coupling with a calibration label to reposition the marks. Accessories Table 34-332. Accessories Frame Size F Overload Relay Description Application Catalog Price Cat. No. C316FNA3 Number U.S. $ DIN Rail and Panel Mounting Adapters — for Frame Size C316F C306TB1 separate mounting of overload relays Frame Size C316K C316TB1 Product Selection Freedom Series Integral Overload Relays Table 34-333. Bimetal Class 10 — Table 34-334. Bimetal Class 10 — IEC Sizes A – F IEC Sizes G – K and IEC Sizes L – S Trip Motor Manual/Automatic Trip Motor Manual/Automatic Class FLA Reset NO-NC Class FLA Reset NO-NC Frame Size K Electrically Separated Electrically Separated Overload Relay Catalog Price Catalog Price Cat. No. C316KNA3 Number U.S. $ Number U.S. $ For IEC Contactor Sizes A – F For IEC Contactor Sizes G – K Product Description 10 .25 – .40 C316FNA3C 10 18.0 – 25.0 C316KNA3A .40 – .63 C316FNA3D 22.0 – 32.0 C316KNA3B ® Eaton’s Cutler-Hammer Integral Over- .63 – 1.00 C316FNA3E 29.0 – 42.0 C316KNA3C 1.00 – 1.40 C316FNA3F 36.0 – 52.0 C316KNA3D load Relays are for use with Freedom 1.30 – 1.80 C316FNA3G 45.0 – 63.0 C316KNA3E Series contactors. They are designed 60.0 – 80.0 C316KNA3F 1.70 – 2.40 C316FNA3H and manufactured to meet IEC (Inter- 2.20 – 3.10 C316FNA3J For IEC Contactor Sizes L – N national Electrotechnical Commis- 2.80 – 4.00 C316FNA3K 10 65 – 90 C316PNA3A sion) recommendations and other 3.50 – 5.00 C316FNA3L 80 – 100 C316PNA3B international standards necessary for 4.50 – 6.50 C316FNA3M 100 – 135 C316PNA3C acceptance in many countries around 6.00 – 8.50 C316FNA3N 110 – 150 C316PNA3D the world. 7.50 – 11.0 C316FNA3P 130 – 175 C316PNA3E 10.0 – 14.0 C316FNA3Q 150 – 200 C316PNA3F 13.0 – 19.0 C316FNA3R 18.0 – 24.0 C316FNA3S 24.0 – 32.0 C316FNA3T Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-270 Freedom March 2009 Starters — Interchangeable Heater ■ One NO right-side mounted auxil- Contents Features iary contact supplied as standard on Description Page Sizes A – N (on Sizes A – C, contact ■ EN60947-4-1 IEC 947-4-1 Compli- occupies 4th power pole — no ance — International Standard for Product Family Overview increase in width). Sizes P – S have low voltage switchgear and control Product Description. . . . . . . 34-261 NO-NC. devices. Features . . . . . . . . . . . . . . . . 34-261 ■ 45 mm open type starters, sizes ■ UL listed and CSA certified. Standards and A – F, have DIN rail or universal base ■ Bimetallic Ambient Compensated 34 Certifications . . . . . . . . . . . 34-261 mounting. DIN rail release mecha- Overload Relays — available in nism conveniently located on line Interchangeable three basic sizes covering applica- side of starter. A steel mounting Heater Starters tions up to 200 hp (100 hp Revers- plate is optional. ing) — reducing number of different Product Description. . . . . . . 34-270 ■ 65 mm starters, sizes G – K; 90 mm contactor/overload relay combina- Features . . . . . . . . . . . . . . . . 34-270 starters, sizes L – N; and P – S tions that have to be stocked. Product Selection . . . . . . . . 34-271 180 mm supplied with steel mount- These overload relays feature: ing plate as standard. Accessories . . . . . . . . . . . . . . . . 34-277 ❑ Selectable Manual or Automatic ■ Four basic starter frame widths — Reset operation. Auxiliary Contacts . . . . . . . . 34-277 45 mm, 65 mm, 90 mm and 180 mm ❑ Interchangeable Heater Packs DC Magnet Coils . . . . . . . . . 34-279 — simplifying panel layout. adjustable ±24% to match motor Renewal Parts. . . . . . . . . . . . . . 34-284 FLA and calibrated for 1.0 and Reversing 1.15 service factors. Heater packs Note: For more information, see ■ Highest horsepower rating in com- for smaller overload relay will CA03402001E. pact, space-saving designs. 45 mm mount in larger overload relay — frame rated maximum 20 hp at useful in derating applications 460V, 65 mm frame rated maximum such as jogging. 50 hp, and 90 mm frame rated maxi- ❑ Meets UL508 Single-Phasing mum 100 hp. requirements, Class 20 or Class ■ 45 mm open type reversing starters, 10 trip time. Sizes A – F, have DIN rail or univer- ❑ Overload trip indication. sal base mounting. DIN rail release ❑ Electrically isolated NO-NC con- mechanisms conveniently located tacts (pull RESET button to test). on line side of starters. A steel mounting plate is optional. ■ Long life twin break, silver cadmium ■ 65 mm reversing starters, Sizes oxide contacts — provide excellent G – K, and 90 mm reversing starters, conductivity and superior resistance Sizes L – N, are supplied with steel to welding and arc erosion. mounting plate as standard. ■ Designed to 2,000,000 electrical and ■ Sizes A – K have a wired NC top IEC Size D 20,000,000 mechanical operations mounted electrical interlock on each Cat. No. AE16DN0BC through 20 hp at 460V. Adequate for contactor. Sizes L – N have one NO- most general duty motor control Product Description NC side mounted electrical inter- applications. lock on each contactor. Non-reversing ■ A full time of snap-on accessories — Non-reversing top and side mounted auxiliary con- IEC Freedom Series Starters utilize an ■ Highest horsepower rating in com- tacts, solid-state and pneumatic tim- Interchangeable Heater Pack Overload pact, space-saving designs, 45 mm ers, etc. Relay which allows increased flexibil- frame rated maximum 20 hp at ■ Straight-through wiring — line lugs ity. Starters are available to cover 460V, 65 mm frame rated maximum at top, load lugs at bottom. 3-phase motors with fractional horse- 50 hp, 90 mm frame rated maximum power ratings up to 900 hp at 480V. ■ Horizontal of vertical mounting 100 hp, and 180 mm rated maxi- on upright panel for application mum 200 hp. Reversing freedom. ■ IP20 finger protection shields ■ Screw type power terminals have Three-phase, full voltage magnetic available. captive, backed-out self-lifting pres- starters are used primarily for revers- ■ Contactor and terminal markings sure plates with ± screws — reduc- ing of 3-phase squirrel cage motors. conform to CENELEC EN50011. ing wiring time. They consist of two contactors and a single overload relay assembled together. The contactors are mechani- cally and electrically interlocked to pre- vent line shorts and energization of both contactors simultaneously. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-271 Freedom March 2009 Starters — Interchangeable Heater Product Selection When Ordering Specify ■ Example: for a Size B starter with a 480V/60 Hz coil, order AE16BNS0CC. ■ Select required starter by Catalog Number and replace the magnet coil ■ For DC Magnet Coils, see Accesso- ries, Page 34-279. alpha designation in the Catalog Num- ber (_) with the proper Code Suffix from Table 34-338 on Page 34-272. 34 � Table 34-335. Type AE16/AE56 Starters — Interchangeable Heater Overload Relay — 3-Pole — Non-reversing Max. UL AC-3 IEC 947 AC-1 Maximum kW Rating Maximum UL Horsepower Catalog Price Ampere Thermal Number U.S. $ 3-Phase 1-Phase 3-Phase Rating Current 220V 380V 415/ 500/ 660V 115V 230V 208V 240V 480V 600V 600V 440V 550V 7 20 1.1 2.2 2.2 4 1.5 1/4 1/2 1-1/2 1-1/2 3 5 AE16ANS0_C 10 20 1.5 4 4 5.5 2.2 1/2 1 2 2 5 7-1/2 AE16BNS0_C 12 20 2.2 5.5 5.5 7.5 4 1/2 2 3 3 7-1/2 10 AE16CNS0_C 18 32 4 7.5 7.5 11 5.5 1 3 5 5 10 15 AE16DNS0_C 25 32 5.5 11 11 15 7.5 2 3 5 7-1/2 15 20 AE16ENS0_C 32 32 7.5 15 15 18.5 10 2 5 7-1/2 10 20 25 AE16FNS0_C 37 50 — 18.5 18.5 22 11 3 5 7-1/2 10 25 30 AE16GNS0_B 44 60 11 22 22 30 15 3 7-1/2 10 15 30 40 AE16HNS0_B 60 75 15 30 30 30 18.5 5 10 15 20 40 40 AE16JNS0_B 73 80 18.5 37 37 37 22 5 10 20 25 50 50 AE16KNS0_B 85 100 22 45 45 55 37 7-1/2 10 25 30 60 75 AE16LN0_ 105 135 30 55 55 75 45 10 10 30 40 75 100 AE16MN0_ 140 175 37 75 75 90 45 10 10 40 50 100 125 AE16NN0_ 170 185 45 90 90 90 45 — — 50 60 125 125 AE16PN0_ 200 220 55 110 110 110 55 — — 60 75 150 150 AE16RN0_ 300 315 90 160 160 160 75 — — 75 100 200 200 AE16SN0_ 450 600 129 220 240 300 300 — — 125 125 250 250 AE16TN0_ 550 760 160 280 315 375 375 — — 150 150 350 350 AE16UN0_ 630 1000 220 375 — 500 500 — — 150 200 400 400 AE16VN0_ 700 1000 220 375 — 500 500 — — 200 250 500 500 AE16WN0_ 860 1100 270 475 — 600 600 — — 250 300 600 600 AE16XN0_ 1215 1350 380 650 — 840 840 — — 450 450 900 900 AE16ZN0_ � IEC Sizes A – N, open are supplied with a NO auxiliary contact. On IEC Sizes A – C, the 4th power pole position is used as the auxiliary contact and adds no additional width. Open type Sizes A – K can be ordered with a top mounted auxiliary contact instead of a side mounted contact. To order, change the 7th digit of the listed Catalog Number from “S” to “T” . Example: AE16ANT0AC. On open type Sizes A – K, if the NO auxiliary contact is not required, drop the “S” from the listed Catalog Number. Example: AE16AN0AC. On IEC Sizes P – S, a NO-NC side mounted is standard. Sizes T – X have 2NO-2NC, Size Z has 2NO-1NC. Accessories . . . . . . . . . . . . . Pages 34-277 – 34-283 Discount Symbol . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-272 Freedom March 2009 Starters — Interchangeable Heater When Ordering Specify ■ Select required starter by Catalog Number and replace the magnet coil alpha designation in the Catalog Number (_) with the proper Code Suffix from Table 34-338 below. ■ Example: for a Size B starter with a 480V/60 Hz coil, order AE16BNS0CC. 34 ■ For DC Magnet Coils, see Accesso- ries, Page 34-279. IEC Size F IEC Size G Cat. No. AE56GN0BB Cat. No. AE56DN0BC � Table 34-336. Type AE16/AE56 Starters — Interchangeable Heater Overload Relay — 3-Pole — Reversing Max. UL AC-3 IEC 947 AC-1 Maximum kW Rating Maximum UL Horsepower Catalog Price Ampere Thermal Number U.S. $ 3-Phase 1-Phase 3-Phase Rating Current 220V 380V 415/ 500/ 660V 115V 230V 208V 240V 480V 600V 600V 440V 550V 7 20 1.1 2.2 2.2 4 1.5 1/4 1/2 1-1/2 1-1/2 3 5 AE56AN0_C 10 20 1.5 4 4 5.5 2.2 1/2 1 2 2 5 7-1/2 AE56BN0_C 12 20 2.2 5.5 5.5 7.5 4 1/2 2 3 3 7-1/2 10 AE56CN0_C 18 32 4 7.5 7.5 11 5.5 1 3 5 5 10 15 AE56DN0_C 25 32 5.5 11 11 15 7.5 2 3 5 7-1/2 15 20 AE56EN0_C 32 32 7.5 15 15 18.5 10 2 5 7-1/2 10 20 25 AE56FN0_C 37 50 — 18.5 18.5 22 11 3 5 7-1/2 10 25 30 AE56GN0_B 44 60 11 22 22 30 15 3 7-1/2 10 15 30 40 AE56HN0_B 60 75 15 30 30 30 18.5 5 10 15 20 40 40 AE56JN0_B 73 80 18.5 37 37 37 22 5 10 20 25 50 50 AE56KN0_B 85 100 22 45 45 55 37 7-1/2 10 25 30 60 75 AE56LN0_ 105 135 30 55 55 75 45 10 10 30 40 75 100 AE56MN0_ 140 175 37 75 75 90 45 10 10 40 50 100 125 AE56NN0_ � Sizes A – K IEC starters do not include holding circuit contacts. For factory installed NO auxiliary contacts, insert “S” (side mounted) or “T” (top mounted) after 6th digit of listed Catalog Number. Example: Change AE56AN0AC to AE56ANS0AC. For “T” , top mounted NC contact blocks are replaced with NO-NC blocks — for “S” , they are replaced with NO-NC side mounted blocks. Table 34-337. Maximum Horsepower Rating Table 34-338. AC Coil Suffixes For DC Magnet Coils, see Accessories of Starters for 380V 50 Hz Application on Page 34-279. Coil Volts and Hertz Code Suffix IEC Size A BCD E F G H 120/60 or 110/50 A hp 3 5 5 10 10 15 20 25 240/60 or 220/50 B 480/60 or 440/50 C IEC Size JK LM N P R S 600/60 or 550/50 D hp 30 40 50 60 75 100 125 150 208/60 E 277/60 H � 208-240/60 J 240/50 K 380-415/50 L 550/50 N � 24/60, 24/50 T 24/50 U 32/50 V 48/60 W 48/50 Y � IEC Sizes A – F only. � IEC Sizes A – F only. Sizes G – V are 24/60 only. Accessories . . . . . . . . . . . . . Pages 34-277 – 34-283 Discount Symbol . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-273 Freedom March 2009 Relays — Interchangeable Heater Overload ■ Electrically isolated NO-NC contacts Contents Features (pull RESET button to test). Description Page ■ Selectable manual or automatic ■ Overload trip indication. reset operation. Product Family Overview ■ Shrouded or “fingerproof” ■ Interchangeable heater packs terminals to reduce possibility of Product Description . . . . . . 34-261 adjustable ±24% to match motor electrical shock. Features . . . . . . . . . . . . . . . 34-261 FLA and calibrated for use with ■ Meets UL508 single-phasing Standards and 1.0 and 1.15 service factor motors. requirements. 34 Certifications . . . . . . . . . . 34-261 ❑ Heater packs for 32 ampere over- Interchangeable Heater load relay will mount in 75 ampere Standards and Certifications Overload Relays overload relay — useful in derat- ing applications such as jogging. Product Description . . . . . . 34-273 ■ UL listed ■ Class 10 or 20 heater packs. Features . . . . . . . . . . . . . . . 34-273 ■ CSA certified ■ Load lugs built into relay base. Standards and ■ NEMA compliance and EN60947-4-1 ■ Bimetallic, ambient compensated Certifications . . . . . . . . . . 34-273 IEC 947-4-1 and (CE) Mark operated. Trip free mechanism. Factory Modifications . . . . 34-273 Accessories. . . . . . . . . . . . . 34-273 Factory Modifications Replacement Parts . . . . . . . 34-274 Product Selection . . . . . . . 34-275 Heater Pack Selection . . . . 34-275 Accessories . . . . . . . . . . . . . . . 34-277 Auxiliary Contacts . . . . . . . 34-277 DC Magnet Coils . . . . . . . . 34-279 Renewal Parts . . . . . . . . . . . . . 34-284 Cat. No. C306TB1 Note: For more information, see CA03402001E. Table 34-339. C306 Thermal Overload Relays with Mounting Adapter Consists of a thermal overload relay mounted to a terminal base adapter — permits fast and easy installation. Description Catalog Price Number U.S. $ C306DN3B + C306TB1 C306DT3B C306GN3B + C306TB2B C306GT3B Accessories Table 34-340. DIN Rail and Panel Mounting Adapter These adapters are required when component overload relays are to be separately mounted. The terminal base adapter includes line terminals and connects with the overload relays listed in Table 34-339. Description Catalog Price Number U.S. $ 32 Ampere Overload Cat. No. C306DN3B For 32 Ampere Overload Relay C306TB1 � For 75 Ampere Overload Relay C306TB2B � This Series “B” adapter will accept Series “A” or “B” overload relays (C306GN3 or C306GN3B). Product Description C306TB2 can only be used with C306GN3. C306 Overload Relays are designed for use with CE or CN non-reversing and reversing contactors. Four sizes are available for overload protection up to 144 amperes. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-274 Freedom March 2009 Relays — Interchangeable Heater Overload Superseded Series A Series B 34 Heater Pack Heater Pack Table 34-341. Locking Cover for Overload Relay — C306 Only Table 34-343. Heater Pack Replacement Requirements Snap-on transparent or opaque plastic panel for covering access port to the overload relay trip setting dial — helps prevent accidental or unautho- Existing Heater Pack Replacement Product Required rized changes to trip and reset setting. Catalog Numbers Description Min. Order Catalog Price H2001-3 – H2013-3 Lug Adapter Kit C3606KAL1-3B and Series B Quantity Number U.S. $ H2001A-3 – H2013A-3 Heater Pack (Std. Pkg.) H2001B-3 – H2013B-3 Series B Heater Pack Clear cover, no accessibility 50 C320PC3 H2014-3 When inventory is exhausted, replace with Gray cover, no accessibility, 50 C320PC4 H2014A-3 Lug Adapter Kit C3606KAL1-3B and Series B with Auto only nib Heater Pack Gray cover, no accessibility, 50 C320PC5 H2014B-3 Series B Heater Pack with Manual only nib H2015-3 – H2017-3 When inventory is exhausted, replace with Gray cover with FLA dial 50 C320PC6 heater pack chosen from Table 34-346 accessibility, A, B, C, D positions H2015A-3 – H2017A-3 When inventory is exhausted, replace with and Auto only nib Lug Adapter Kit C3606KAL1-3B and Series B Gray cover with FLA dial 50 C320PC7 Heater Pack accessibility, A, B, C, D positions H2015B-3 – H2017B-3 Series B Heater Pack and Manual only nib Table 34-344. Heater Pack Ratings Overload Lug Adapter Kit Motor Full Load Ampere Rating Order Price These kits are used in conjunc- Heater Pack U.S. $ Dial Position tion with Catalog Numbers Catalog Number H2001B – H2014B or H2101B – A BCD H2114B heater packs as a 29.0 32.5 36.0 39.5 H2015A-3 means of utilizing these Series 39.6 44.3 49.1 53.8 H2016A-3 “B” heater packs in Catalog 53.9 60.4 66.8 74.9 H2017A-3 Cat. No. C306KAL1-3 Numbers C306DN3 and Overload Relay Lug C306GN3 Series “A1” overload Adapter Kit Overload Relay Replacement — Series “A” Only relays. The kit consists of 3 When replacing a Catalog Number C306DN3 (Part Number lug adapters and installation 10-6044) or C306GN3 (10-6319) Series “A” overload relay on instructions. When installing Series “B” heater packs plus a starter, order a Series “B” overload relay and Series “B” lug adapters in Series “A” overload relays, refer to heater heater packs. pack FLA adjustment tables originally supplied with equip- ment (also supplied with kit). Table 34-342. Product Selection Description Catalog Price Number U.S. $ Series “A1” Overload C306KAL1-3B Relay Lug Adapter Kit Replacement Parts Heater Pack Replacement Superseded 32 Ampere Superseded 75 Ampere The heater pack series is determined by the 6th character of Series “A” Overload Relay Series “A” Overload Relay the Catalog Number. Series A or prior heater packs (identi- Cat. No. C306DN3 Cat. No. C306GN3 fied by either “A” or “-” as the 6th character) have built-in load lugs. Series B or later heater packs do not (load lugs are on overload relay). Replacement of Series A or earlier heater packs with Series B or later heater packs, requires the one time addition of Lug Adapter Kit C3606KAL1-3B to the Series A1 overload relay. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-275 Freedom March 2009 Relays — Interchangeable Heater Overload Product Selection 34 32A Overload 75A Overload Cat. No. C306DN3B Cat. No. C306GN3B Table 34-345. C306 Thermal Overload Relays For Use with Freedom Maximum Number Open Type Open Type with Adapter for NEMA 1 Enclosed Series Contactors Ampere of DIN Rail or Panel Mount Rating Poles NEMA IEC Catalog Price Catalog Price Catalog Price Number U.S. $ Number U.S. $ Number U.S. $ � 00, 0 A – F 32 3 C306DN3B C306DT3B C306DG3B � 1, 2 G – K 75 3 C306GN3B C306GT3B C306GG3B � 3 L – M 105 3 C306KN3 — — � 4 N 144 3 C306NN3 — — � 5 – 8 — — — — — — � NEMA Sizes 5 – 8 use the 32 ampere overload in conjunction with CTs. � Series “B” overload relays have load lugs built into relay base and will only accept Series “B” heater packs. These relays can be directly attached to contactor or they can be DIN rail mounted using adapter on Page 34-273. � These relays can be panel mounted only. Heater Pack Selection Heater Pack Heater Pack Heater Pack H2001B – H2017B H2101B – H2117B H2018 – H2024 Heater packs H2001B to H2017B and Table 34-346. Starters with Series B H2101B to H2117B are to be used only Overload Relays with Series B overload relays Catalog NEMA — AN Type IEC — AE Type Numbers C306DN3B (Part No. 10- Size Series Size Series 7016) and C306GN3B (Part No. 10- 7020). The load lugs are built into the 00 – 0 C A – F C 1 – 2 B G – K B overload relay base to allow load wir- 5 B ing prior to heater pack installation. 6 C The previous heater design had inte- 7 – 8 B gral load lugs. The Series B heater Note: The series of a starter is the last digit packs are electrically equivalent to the of the listed Catalog Number. EXAMPLE: previous heater design. Heaters AE16DN0AB. H2018-3 to H2024-3 have not changed. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-276 Freedom March 2009 Relays — Interchangeable Heater Overload Table 34-347. Standard Trip — Class 20 Table 34-348. Fast Trip — Class 10 Overload Motor Full Load Ampere Rating Catalog Price Overload Motor Full Load Ampere Rating Catalog Price Relay Size Number U.S. $ Relay Size Number U.S. $ Dial Position Dial Position (Includes 3 (Includes 3 A BCD A BCD Heater Heater Packs) Packs) For Use with NEMA Sizes 00 – 0 Series C, NEMA Sizes 1 – 2 Series B; For Use with NEMA Sizes 00 – 0 Series C, NEMA Sizes 1 – 2 Series B; IEC Sizes A – F Series C, IEC Sizes G – K Series B IEC Sizes A – F Series C, IEC Sizes G – K Series B 34 32A or .254 .306 .359 .411 H2001B-3 32A or .260 .313 .367 .420 H2101B-3 75A .375 .452 .530 .607 H2002B-3 75A .384 .464 .543 .623 H2102B-3 .560 .676 .791 .907 H2003B-3 .570 .688 .806 .924 H2103B-3 .814 .983 1.15 1.32 H2004B-3 .846 1.02 1.20 1.37 H2104B-3 1.20 1.45 1.71 1.96 H2005B-3 1.28 1.55 1.83 2.10 H2105B-3 1.79 2.16 2.53 2.90 H2006B-3 1.92 2.33 2.74 3.15 H2106B-3 2.15 2.60 3.04 3.49 H2007B-3 2.30 2.79 3.28 3.77 H2107B-3 3.23 3.90 4.56 5.23 H2008B-3 3.38 4.10 4.82 5.54 H2108B-3 4.55 5.50 6.45 7.40 H2009B-3 4.96 6.03 7.09 8.16 H2109B-3 6.75 8.17 9.58 11.0 H2010B-3 7.07 8.58 10.1 11.6 H2110B-3 9.14 10.8 12.4 14.0 H2011B-3 9.60 11.2 12.8 14.4 H2111B-3 14.0 16.9 19.9 22.8 H2012B-3 14.4 17.5 20.7 23.8 H2112B-3 18.7 22.7 26.7 30.7 H2013B-3 18.7 21.8 25.0 28.1 H2113B-3 23.5 28.5 33.5 38.5 H2014B-3 23.5 27.3 31.0 34.8 H2114B-3 For Use with NEMA Size 2, IEC Sizes G – K Only — Series B For Use with NEMA Size 2, IEC Sizes G – K Only — Series B 75A 29.0 34.0 39.1 44.1 H2015B-3 75A 28.3 32.6 37.0 41.3 H2115B-3 39.6 45.5 51.5 57.4 H2016B-3 36.6 42.3 48.1 53.8 H2116B-3 53.9 60.9 67.9 74.9 H2017B-3 53.8 60.8 67.9 74.9 H2117B-3 For Use with NEMA Sizes 3 – 4, IEC Sizes L – N Only — Series A For Use with Size 5 Starters Only — Series B and IEC P, R and S with 300/5 CT � 105A or 8.0 9.2 10.3 11.5 H2025-3 32A 51 61 72 82 H2104B-3 144A 11.4 12.8 14.3 15.7 H2026-3 77 93 110 126 H2105B-3 14.3 15.7 17.4 19.0 H2027-3 115 140 164 189 H2106B-3 18.0 20.2 22.3 24.5 H2018-3 138 167 197 226 H2107B-3 24.6 27.6 30.5 33.4 H2019-3 203 246 289 — H2108B-3 33.5 37.5 41.5 45.6 H2020-3 For Use with Size 6 Starters Only — Series B and IEC T – V with 600/5 CT 45.7 51.2 56.7 62.1 H2021-3 � 32A 154 186 220 252 H2105B-3 62.2 69.7 77.1 84.6 H2022-3 230 280 329 378 H2106B-3 84.7 95.0 105.0 115.0 H2023-3 276 335 394 452 H2107B-3 106.0 118.0 131.0 144.0 H2024-3 406 492 578 — H2108B-3 For Use with Size 5 Starters — Series B and IEC P, R and S with 300/5 CT For Use with Size 7 Starters Only — Series B and IEC W – X with 1000/5 CT � 32A 49 59 69 79 H2004B-3 � 32A 169 204 240 274 H2104B-3 72 87 103 118 H2005B-3 256 310 366 420 H2105B-3 107 130 152 174 H2006B-3 384 466 543 630 H2106B-3 129 156 182 209 H2007B-3 460 558 656 754 H2107B-3 194 234 274 — H2008B-3 676 820 — — H2108B-3 For Use with Size 6 Starters Only — Series B and IEC T – V with 600/5 CT For Use with Size 8 Starters Only — Series B and IEC Z with 1500/5 CT � 32A 144 174 205 235 H2005B-3 � 32A 254 306 360 411 H2104B-3 215 259 304 348 H2006B-3 384 465 549 630 H2105B-3 258 312 365 419 H2007B-3 576 699 822 945 H2106B-3 388 468 547 627 H2008B-3 690 837 984 1131 H2107B-3 For Use with Size 7 Starters Only — Series B and IEC W – X with 1000/5 CT 1014 1230 — — H2108B-3 � � 32A 163 197 230 264 H2004B-3 Sizes 5 – 8 and IEC P – Z use the 32A overload relay with current 240 290 342 392 H2005B-3 transformers. 358 432 506 580 H2006B-3 Note: Heater packs are shipped 3 to a carton. Catalog Numbers are 430 520 608 698 H2007B-3 for 3 heater packs. 646 780 912 — H2008B-3 For Use with Size 8 Starters Only — Series B and IEC Z with 1500/5 CT � 32A 244 295 345 396 H2004B-3 360 435 513 588 H2005B-3 537 648 759 870 H2006B-3 645 780 912 1047 H2007B-3 969 1170 1368 — H2008B-3 � Sizes 5 – 8 and IEC P – Z use the 32A overload relay with current transformers. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-277 Freedom March 2009 Accessories Contact Configuration Code Auxiliary Contacts This two-digit code is found on the auxiliary contact to assist NEMA Sizes 00 – 2 — IEC Sizes A – K in identifying the specific contact configuration. The first The auxiliary contacts listed below are designed for installa- digit indicates the quantity of NO contacts and the second tion on Freedom Series starters and contactors. Snap-on indicates the quantity of NC contacts. design facilitates quick, easy installation. NEMA Sizes 3 – 8 — IEC Sizes L – Z These bifurcated design contact blocks, featuring silver Table 34-350. Product Selection 34 cadmium alloy contacts, are well suited for use in very low Circuit Contact Catalog Number Price energy (logic level) circuits. Configuration U.S. $ � Code Base Auxiliary Contacts — NEMA Sizes 3 – 5, IEC Sizes L – S NEMA Size 3 NEMA Sizes 4 – 5 IEC Sizes L – N IEC Sizes P – S NO 10 C320KGS31 C320KGS41 NO-NC 11 C320KGS32 C320KGS42 Auxiliary Contacts — NEMA Sizes 3 – 5, IEC Sizes L – S Catalog Number NO 10 C320KGS20 NC 01 C320KGS21 Side Mounted Top Mounted � NO-NC 11 C320KGS22 Auxiliary Contacts — NEMA Sizes 6 – 8, IEC Sizes T – Z Table 34-349. Selection Product Size Catalog Number Description Contact Catalog Price Configuration Number U.S. $ NO-NC 11 NEMA 8, IEC Z C320KA5 � Code 2NO-2NC 22 NEMA 6 – 7 C320KA6 2NO-2NC 22 IEC T – X C320KA8 Side Mounted � For reference only — not part of Catalog Number. See above. 1NO 10 C320KGS1 � NO-NC occupies two positions — L2 and L3, or R2 and R3. See next 1NO (Logic Level) 10 C320KGS1L page. 1NC 01 C320KGS2 1NO-1NC 11 C320KGS3 1NO-1NC (Logic Level) 11 C320KGS3L 2NO 20 C320KGS4 2NO (Logic Level) 20 C320KGS4L 2NC 02 C320KGS5 1NO-1NCI N/A C320KGS6 1NO (EC)-1NC (LO) N/A C320KGS7 1NCI N/A C320KGS8 Top Mounted 1NO 10 C320KGT1 Base Auxiliary Contact Auxiliary Contact 1NC 01 C320KGT2 Cat. No. C320KGS42 Cat. No. C320KGS22 1NO-1NC 11 C320KGT3 1NO-1NC (Logic Level) 11 C320KGT3L 2NO 20 C320KGT4 2NC 02 C320KGT5 1NO-1NCI N/A C320KGT6 1NO (EC)-1NC (LO) N/A C320KGT7 1NCI N/A C320KGT8 3NO 30 C320KGT9 2NO-1NC 21 C320KGT10 1NO-2NC 12 C320KGT11 3NC 03 C320KGT12 4NO 40 C320KGT13 3NO-1NC 31 C320KGT14 2NO-2NC 22 C320KGT15 2NO-2NC (Logic Level) 22 C320KGT15L 1NO-3NC 13 C320KGT16 4NC 04 C320KGT17 3NO-1NCI N/A C320KGT18 2NO-1NCI-1NC N/A C320KGT19 2NO-1NO (EC)-1NC (LO) N/A C320KGT20 1NO-1NC-1NO (EC)-1NC (LO) N/A C320KGT21 Note: NCI = Normally Closed early opening designed for use in reversing applications. EC = Early Closing. LO = Late Opening. � For reference only — not part of Catalog Number. See above right. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com Rear IEC Contactors & Starters 34-278 Freedom March 2009 Accessories NEMA Sizes 3 – 8, IEC Sizes L – Z Auxiliary Contact Location The sketches below illustrate the maximum number of auxil- NEMA Sizes 00 – 2, IEC Sizes A – K iary contacts that can be assembled to a contactor and their The sketches below illustrate the maximum number of auxil- locations. iary contacts that can be assembled to a contactor or starter Note: A Base Auxiliary Contact must be added in position R1 before and their locations. additional auxiliary contacts can be mounted on NEMA Size 3 and IEC Sizes L – N, or in L1 on NEMA Sizes 4 – 5 and IEC Sizes P – S. Table 34-351. Auxiliary Contacts 34 �� Catalog Size Poles Available Mounting Positions Table 34-352. Auxiliary Contacts Number Open Type Enclosed � Size Available Mounting Positions AE16 A – K 3 T1, L1 L1 NEMA Size 3, IEC Sizes L – N R2, R3, L1, L2, L3 AN16 00 3 T1, L1, R1 L1 NEMA Sizes 4 – 5, IEC Sizes P – S L2, L3, R1, R2, R3 0 – 2 3 T1, L1 L1 NEMA Sizes 6 – 7, IEC Sizes T – X R1 AE56 A – K 3 L1, R1 L1, R1 NEMA Size 8, IEC Size Z L2, R2 AN56 00 – 2 3 T1, T2 — � Available positions on contactors or starters other than what is factory CE15 A – C 2 – 4 T1, L1, R1 L1, R1 installed. D – K 3 T1, L1 L1 G – J 4 T1, R1 — G – J 5 T1 — CN15 00 2 – 4 T1, L1, R1 L1 L1 R1 L2 L3 R3 R2 0 – 2 2 – 3 T1, L1 L1 1, 2 4 T1, L1 — Base Base Aux. Aux. Aux. Aux. 1, 2 5 T1, L1 — Aux. Aux. Cont. Cont. Cont. Cont. Cont. Cont. CN35 10A 2 – 4 T1, L1, R1 L1 20 – 60A 2 – 3 T1, L1 L1 60A 4 T1, L1 — Left Side Front Right Side 60A 5 T1, L1 — of Contactor of Contactor of Contactor CE55 A – K 3 L1, R1 L1, R1 NEMA Sizes 3 – 5 CN55 00 – 2 3 T1, T2 — IEC Sizes L – S � Available positions on contactors or starters other than what is factory installed. � When a pneumatic timer is mounted on contactor, only side mounted auxiliary contact positions are available. The solid-state timer, when added, takes up side mounted auxiliary contact position. L1 R1 NEMA Sizes 6 – 7 L1 R1 L1 R1 IEC Sizes T, U, V, W and X T1 T1 T2 Top View Top View L1 R1 L2 R2 L1 R1 L1 R1 T1 T1 T2 NEMA Size 8 IEC Size Z Figure 34-168. Auxiliary Contact Location Front View Front View Non-reversing Reversing Contactors and Starters Contactors and Starters Figure 34-167. Auxiliary Contact Location For more information visit: www.eaton.com CA08102001E Rear IEC Contactors & Starters 34-279 Freedom March 2009 Accessories Note: For NEMA Sizes 00 and 0 and IEC Non-reversing Kit Consists of: DC Magnet Coils Sizes A – F, contactors may utilize either ■ 1 Encapsulated DC magnet coil suffix 1 or 4 DC coil kits; starters may utilize When Ordering Specify ■ 1 NCI or NO/NCI side mounted suffix 4 DC coil kits only. For NEMA Sizes 1 Conversion Kit for Field Assembly auxiliary contact and 2 and IEC Sizes G – K, both contactors ■ Catalog Number and starters may utilize a suffix 4 DC coil kit Note: These kits are supplied with a NO/ only. NCI side mounted auxiliary contact in Factory Installed DC Coil place of the NCI contact. On the above sizes only, when the ■ For factory installed DC magnet coil ■ 2 Blue colored connection wires 34 special auxiliary package is mounted on AC contactors or non-combina- ■ 1 Instruction publication on the side of a contactor or starter, tion starters (open type only), sub- no standard auxiliary contact may be stitute the Code Suffix from table Operation mounted on the same side. below for the magnet coil identifier These DC coil kits have separate pick- in the device Catalog Number. up and seal windings. A special (side Note: For NEMA Sizes 3 – 5 and IEC Sizes EXAMPLE: For Size 0 AC contactor L – S, the special coil NCI clearing contact is mounted) early-break NCI auxiliary with a 24V DC coil, change an add-on auxiliary (must mount on a base contact is used to either disconnect the CN15BN3AC to CN15BN3T1C. mount auxiliary contact; normally a 1NO). pick-up winding or insert the seal This arrangement will normally account for winding in series with the pick-up Application two of the three contact positions on the winding, depending on the frame size side of each contactor or starter. ■ Connect for separate control of the contactor. DC coil kits come in ■ Not for use with cover control two styles, a suffix 1 and a suffix 4. The switch operators 1 suffix contains only the special (side ■ Use twin break, heavy-duty pilot mounted) early break NCI auxiliary contact. The 4 suffix contains a NO devices contact in the same package as the ■ Designed for +10%, -20% rated volt- special (side mounted) early-break NCI age, continuous duty operation auxiliary contact. Table 34-353. Product Selection DC Magnet Coils Contactor or Conversion Data Complete Conversion Kit Factory Installed Starter Size Volts Magnet Coil NCI Interlock NEMA IEC Coil Amps Watts Catalog Price Ship Wt. Code Adder Number Number P.U./Seal P.U./Seal Number U.S $ Lbs. (kg) Suffix U.S $ Non-reversing — Kit includes NCI Side Mounted Auxiliary Contact 00 and 0 A – F 12 9-2988-11 6.4/.28 76.8/3.36 C320KGD1 C335KD3R1 1.0 (.5) R1 CN35 – A, B, D 24 9-2988-12 3.2/.14 76.8/3.36 C320KGD1 C335KD3T1 T1 D15 Relays 48 9-2988-13 1.6/.07 76.8/3.36 C320KGD1 C335KD3W1 W1 120 9-2988-14 .64/.028 76.8/3.36 C320KGD1 C335KD3A1 A1 � � A – F 12 9-2988-11 6.4/.28 76.8/3.36 C320KGD2 C335KD3R4 1.0 (.5) R4 � 00 and 0 24 9-2988-12 3.2/.14 76.8/3.36 C320KGD2 C335KD3T4 T4 � CN35 – A, B, D 48 9-2988-13 1.6/.07 76.8/3.36 C320KGD2 C335KD3W4 W4 � D15 Relays 120 9-2988-14 .64/.028 76.8/3.36 C320KGD2 C335KD3A4 A4 1 and 2 G – K 12 9-2990-1 15.4/.42 185/4.98 C320KGD5 C335KD4R4 1.0 (.5) R4 CN35 – G 24 9-2990-2 7.7/.21 185/4.96 C320KGD5 C335KD4T4 T4 48 9-2990-3 3.9/.11 185/5.04 C320KGD5 C335KD4W4 W4 120 9-2990-4 1.5/.041 185/4.87 C320KGD5 C335KD4A4 A4 3 L – N 12 9-3002-1 24/.40 293/4.84 C320KGD3 C335KD5R1 2.0 (.9) R1 CN35 – K 24 9-3002-2 12/.20 288/4.75 C320KGD3 C335KD5T1 T1 48 9-3002-3 6.1/.097 295/4.67 C320KGD3 C335KD5W1 W1 120 9-3002-4 2.5/.038 298/4.57 C320KGD3 C335KD5A1 A1 4 and 5 P – S 24 9-2026-4 18/.22 400/5.3 C320KGD3 C335KA3T1 2.5 (1.1) T1B CN35 – N, S 48 9-2026-3 9/.11 400/5.2 C320KGD3 C335KA3W1 W1B 120 9-2026-2 3.3/.05 450/5.4 C320KGD3 C335KA3A1 A1B 240 9-2026-1 1.7/.02 440/4.9 C320KGD3 C335KA3B1 B1B Reversing � � �� � 00 and 0 A – F 12 9-2988-1 6.4/.28 76.8/3.36 C320KGD1 C335KD3R1 1.0 (0.9) R1 � � �� � CN35 – A, B, D 24 9-2988-2 3.2/.14 76.8/3.36 C320KGD1 C335KD3T1 T1 � � �� � D15 Relays 48 9-2988-3 1.6/.07 76.8/3.36 C320KGD1 C335KD3W1 W1 � � �� � 120 9-2988-4 .64/.028 76.8/3.36 C320KGD1 C335KD3A1 A1 � � � � 1 and 2 G – K 12 9-2990-1 15.4/.42 185/4.98 C320KGD3 R1 � � � CN35 – G 24 9-2990-2 7.7/.21 185/4.96 C320KGD3 T1 � � � 48 9-2990-3 3.9/.11 185/5.04 C320KGD3 W1 � � � 120 9-2990-4 1.5/.041 185/4.87 C320KGD3 A1 � These kits are supplied with a NO/NCI side mounted auxiliary contact in place of the NCI contact. � Kit does not include mechanical interlock or crossover wiring. Two NO/NCI top mounted auxiliary contacts are supplied for electrical interlocking. � Factory installed DC coils on NEMA contactors and starters include a NO/NC top mounted auxiliary contact on each contactor for electrical interlock- ing. On IEC contactors and starters, a NC top mounted auxiliary contact is supplied on each contactor for electrical interlocking. � Available factory assembled only. � Two required per reversing assembly. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-280 Freedom March 2009 Accessories Table 34-356. Metal Mounting Plates — Approximate Dimensions and Shipping Weights Remote Reset Module Catalog Dimensions in Inches (mm) Ship (32A Overload Relay) Number Wt. Wide High Mounting The C316RR remote reset module for Lbs. (kg) the C316F, C316S and C316U overload C321MP1 2.00 (50.8) 3.88 (98.6) 1.50 x 3.38 (38.1 x 85.9) .2 (.1) relays allows remote resetting of C321MP2 2.56 (65.0) 5.05 (128.3) 2.00 x 4.50 (50.8 x 114.3) .4 (.2) tripped (32A) overload relays by � C321MP3 1.80 (45.7) 6.60 (167.6) 6.07 (154.2) .7 (.3) means of an electrical solenoid attach- C321MP4 2.56 (65.0) 8.08 (205.2) 2.00 x 7.63 (50.8 x 193.8) .6 (.3) 34 � ment which mounts on the side of the C321MP5 1.77 (45.0) 4.63 (117.6) 4.27 (108.5) .3 (.1) overload relay. C321MP6 2.52 (64.0) 5.14 (130.6) 2.00 x 4.59 (50.8 x 116.6) .4 (.2) C321MP7 4.20 (106.7) 7.38 (187.5) 3.50 x 6.87 (88.9 x 174.5) .8 (.4) Table 34-354. Product Selection C321MP8 4.20 (106.7) 4.35 (110.5) 3.50 x 3.86 (88.9 x 98.0) .5 (.2) C321MP9 5.66 (143.8) 5.05 (128.3) 5.25 x 3.63 (133.4 x 92.2) .8 (.4) Remote Reset Module Catalog Price � Operating Voltage Number U.S. $ C321MP11 8.70 (221.0) 11.35 (288.3) 7.00 x 10.81 (177.8 x 274.6) 1.2 (.5) � C321MP12 5.71 (145.0) 8.08 (205.2) 5.25 x 6.75 (133.4 x 171.5) .9 (.4) 24V 50/60 Hz C316RR1U � C321MP13 8.70 (221.0) 7.17 (182.1) 7.00 x 6.63 (177.8 x 168.4) .9 (.4) 110V 50/60 Hz C316RR1A � 2-hole mounting. � 3-hole mounting. Metal Mounting Plates 3-Pole Top Mounted Fuse Block Kit IEC Sizes A – K, NEMA Sizes 00 – 2 Field mount to Freedom Series starters and contactors. Designed to save space and reduce installation costs. They provide short circuit protection for branch circuits. Table 34-357. Selection Product Table 34-355. For Use on IEC Style Contactors, Starters and Overload Relays Fuse Type Catalog Price Number U.S. $ Application Catalog Price Number U.S. $ Class H — 30A 250V C350KH21 Class R — 30A 250V C350KR21 Contactors IEC Sizes A – F C321MP1 Class G — 15A 300V C350KG37 IEC Sizes G – K C321MP2 Class G — 20A 300V C350KG38 Class G — 30A 300V C350KG31 Non-reversing Starters Class G — 60A 300V C350KG32 IEC Sizes A – F C321MP3 IEC Sizes G – K C321MP4 Class T — 30A 300V C350KT31 Class T — 60A 300V C350KT32 � Overload Relays 32A C321MP5 Class J — 30A 600V C350KJ61 75A C321MP6 Class J — 60A 600V C350KJ62 � Type M — 30A 600V C350KM61 Reversing Starters Class CC — 30A 600V C350KC63 IEC Sizes A – F C321MP7 IEC Sizes G – K C321MP12 Class T — 30A 600V C350KT61 IEC Sizes L – N C321MP11 Class T — 60A 600V C350KT62 � Reversing Contactors Type M fuse block not approved for branch circuit protection. IEC Sizes A – F C321MP8 IEC Sizes G – K C321MP9 IEC Sizes L – N C321MP13 � For use with DIN rail and base mounting adapters listed on Page 34-273. Discount Symbol (Remote Reset). . . . . . . . . 1CD7 Discount Symbol (Mounting Plates) . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-281 Freedom March 2009 Accessories Mechanical Interlock and Reversing Kits Solid-State Timers Mechanical interlocks and reversing kits are designed for Solid-State ON DELAY Timer — Side Mounted on Freedom Series field assembly of reversing contactors or starters from Free- NEMA 00 – 2, IEC A – K and C25D, C25E and C25F Frame dom Series components. The Reversing Kits include a This timer is designed to be wired in Mechanical Interlock, stabilizer bar and a pre-cut, trimmed SERIES with the load (typically a coil). and formed wire set. Auxiliary contacts, if required, must be When the START button is pushed ordered separately. See Page 34-277. (power applied to timer), the ON DELAY 34 timing function starts. At the completion of the set timing period, timer and series wired load will both be energized. Table 34-360. Product Selection — Mounted Timer Timing Range Catalog Price ��� Number U.S. $ .1 – 1.0 Seconds C320TDN1_ Cat. No. Part No. Wire Set 1 – 30 Seconds C320TDN30_ C321KM60B 23-7165 30 – 300 Seconds C320TDN300_ 5 – 30 Minutes C320TDN2000_ � Add operating voltage Suffix to Catalog Number. A = 120V, B = 240V, Table 34-358. Reversing Kits (Horizontal Contactor Mounting Only) E = 208V Application Catalog Price � Rated .5 ampere pilot duty – not to be used on larger contactors. Number U.S. $ � NEMA Size IEC Size Terminal connections are quick connects only. Two per side. 00 A – C C321KM60K14B Shorting Bar Kits 0 D – F C321KM60K13B 1 — C321KM60K15B These kits provide phase-to-phase power connections of 2 G – K C321KM60K16B contactors for field assembly. The kits include bus connec- � 3 — C321KM60K17 tions and mounting hardware. The shorting bars connect all � — L and M C321KM60K21 three phases of a single contactor. � — N C321KM60K18 � 4 — C321KM60K19 Table 34-361. Product Selection � 5 — C321KM60K20 � Description Catalog Price — P – S C321KM60K44 Number U.S. $ � Kit includes (2) NC auxiliary contacts. NEMA Size 3, IEC Sizes L – N C321SB18 �� Table 34-359. Mechanical Interlock Only NEMA Size 4, IEC Sizes P – S C321SB19 NEMA Size 5 C321SB21 Application Catalog Price NEMA Size 6, IEC Sizes T and U C321SB22 Number U.S. $ NEMA Size IEC Size Contactor Mounting Pneumatic Timers — Top Mounted 00 – 2 A – K Horizontal C321KM60B Attachment mounts on top of any NEMA Size 3 L – N Horizontal C321KM30 00 – 2 or IEC Size A – K Freedom Series starter 3 to 4 N to P Horizontal C321KM43 or contactor (top mounted auxiliary contacts 4 P – S Horizontal C321KM40 can not be installed on device when timer is 4 to 5 — Horizontal C321KM45 used). Timer unit has 1NO-1NC isolated timed contacts — circuits in each pole must be the same polarity. 4 to 6 S to T/U Horizontal C321KM80 Units are convertible from OFF to ON DELAY or vice-versa. 5 — Horizontal C321KM50 5 to 6 — Horizontal C321KM56 Table 34-362. Maximum Ampere Ratings 6 T and U Horizontal C321KM70 Description Volts AC 6 to 7 T/U to V – X Horizontal C321KM90 120 240 480 600 7 V, W and X Horizontal C321KM34 Make 30 15 7.5 6 4 or 5 to 5 P – S to 5 Vertical C321KM55 Break 3 1.5 .75 .6 5 to 6 — Vertical C321KM65 6 T and U Vertical C321KM66 Table 34-363. Product Selection 6 to 7 T/U to V – X Vertical C321KM67 Timing Range Catalog Price Number U.S. $ � Without cross-wiring. � For use with latest series product. .1 to 30 Seconds C320TP1 10 to 180 Seconds C320TP2 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-282 Freedom March 2009 Accessories Locking Cover for Overload Relay — C306 Only Transient Suppressor Kits Snap-on transparent or opaque plastic panel for covering access port to the over- NEMA Sizes 00 – 2, IEC Sizes A – K load relay trip setting dial — helps prevent accidental or unauthorized changes to These kits limit high trip and reset setting. voltage transients pro- duced in the control Table 34-364. Product Selection circuit when power is Description Min. Ordering Catalog Price removed from the con- Qty. (Std. Pkg.) Number U.S. $ 34 tactor or starter coil. Clear cover, no accessibility 50 C320PC3 There are three sepa- Gray cover, no accessibility, with Auto 50 C320PC4 rate suppressors for Cat. No. only nib use on 24 – 120V, 208 – C320TS2 Gray cover, no accessibility, with Manual 50 C320PC5 240V or 277 – 480V coils only nib respectively. Gray cover with FLA dial accessibility, 50 C320PC6 These devices mount directly to the A, B, C, D positions an Auto only nib coil terminals of Freedom Series con- Gray cover with FLA dial accessibility, 50 C320PC7 tactors or starters NEMA Sizes 00 – 2, A, B, C, D positions and Manual only nib IEC Sizes A – K and lighting contactors 10 – 60A. Reversing devices will Control Circuit Fuse Block Finger Protection Shields require two. These panel mounted Snap-on shields for both contactors Table 34-369. Product Selection fuse holders, designed and starters provide IEC Type IP20 Description Coil Voltage Catalog Price for control circuit protec- Finger Protection. Prevents accidental � 50/60 Hz Number U.S. $ tion or other similar low contact with line/load terminals. current requirements, Transient 24 – 120V C320TS1 Table 34-367. Product Selection have extractor type fuse Suppressor 208 – 240V C320TS2 Application Catalog Price caps. The Class CC rejection type fuses 277 – 480V C320TS3 Number U.S. $ (KTK-R) used in these holders are � Suppressor is compatible with coil voltages/ intended for use with equipment ranges as shown, 50 and 60 Hz. NEMA Size 00, C320LS1 designated as being suitable for use IEC Sizes A – C NEMA Sizes 3 – 5, IEC Sizes L – S on systems having high available fault NEMA Size 0, C320LS2 IEC Sizes D – F This device mounts on currents. If branch circuit protective top of any side mounted device is 45A or greater, C320FBR fuse NEMA Sizes 1 – 2, IEC Sizes G – K auxiliary contact on kit may be required for control circuit Contactors C320LS3 Freedom Series NEMA protection per NEC 430-72. Reversing Contactors C320LS4 Sizes 3 – 5, IEC Sizes Table 34-365. Product Selection NEMA Size 1 L – S and lighting con- Starters C320LS5 Type Max. Catalog Price tactors 100 – 300A. It connects across Reversing Starters C320LS6 Amperes Number U.S. $ coil terminals on any 120V contactor NEMA Size 2, or starter magnet coil (reversing start- � Fuse Holder 15 C320FB IEC Sizes G – K ers or contactors require 2). � Only 30 C320FBR Starters C320LS7 Reversing Starters C320LS8 � A fuse is not supplied, but holder will Limits high voltage transients pro- accept a Bussman Type KTK or KTK-R duced in the circuit when power is (13/32" x 1-1/2") fuse, 600V maximum. Adapter to DIN Rail Mount removed from the coil. � Includes a 5A, 600V KTK-R fuse. NEMA 1 – 2 and IEC G – K Contactors Table 34-370. Product Selection Designed to allow DIN rail mounting of DIN Rail Mounting Channel — Description Coil Catalog Price NEMA 1 – 2 and IEC G – K contactors. Voltage Number U.S. $ 35 mm Includes all hardware required to con- Designed for DIN rail mounting of IEC vert contactors from panel mounting Transient 120V C320AS1 style contactors and starters. Suppressor to 35 mm DIN rail mounting. Table 34-368. Product Selection Catalog Price Number U.S. $ C320DN65 DIN Rail Table 34-366. Product Selection Description Catalog Price Number U.S. $ 1 Meter Length MC382MA1 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-283 Freedom March 2009 Accessories DC/AC Interface Module Adhesive Dust Cover The Catalog Number NEMA Sizes 00 – 2, IEC Sizes A – K Table 34-373. Product Selection C320DC Interface These adhesive stickers come 25 to a Description Catalog Price Module is an optically Number U.S. $ package and provide extra protection isolated solid-state from contaminants when applied to switch which provides 25 to a package C320DSTCVR the sides of Freedom NEMA Sizes a means of operating 00 – 2 and IEC Sizes A – K. Adhesive AC coils with a 5 – 48V 34 covers are easily applied to side open- DC control signal. It Cat. No. ing where auxiliaries are not installed acts as a space saving C320DC and provide extra protection from interposing relay which metal filings and other debris. can switch a specified 50/60 Hz AC source to the contactor or starter coil. Add-On Power Pole Kit The module may be directly attached NEMA Sizes 00 – 2, IEC A – K to the coil terminals of any Freedom Series contactor or starter — NEMA This device mounts on the side of Freedom NEMA Size 00 – 2 and IEC Size A – K Sizes 00 – 3, IEC Sizes A – N and light- contactors. One unit can be mounted on each side and carries UL, cUL and IEC rat- ing contactors 10 – 100A. It also has ings. The device is rated for resistive, inductive and lighting applications. provisions for DIN rail mounting. Table 34-374. Product Selection — Add-On Power Pole Kit The module will operate coils within UL Ampere Rating IEC 947 Ampere Rating 1NO Price the voltage ranges shown below. Power U.S. $ Inductive Resistive hp Locked Lighting AC-1 AC-3 AC-5a Pole 600V 600V 1-Phase Rotor Ballast 600V 600V AC-5b Design Characteristics Catalog 240V Tungsten 480V 115V 230V Number ■ DC Input: 5 – 48V DC ±10% at 480V mA nominal 15 20 1/2 2 96 20 20 12 18 C320PPD10 ■ AC Operating Voltage: 240V AC max. (360 VA) ±10% 50/60 Hz ■ DC Operating Voltage: 30V DC max. (5A) ■ AC Current Rating: ❑ 10A make (inrush) ❑ 1A break (sealed) Table 34-371. Controller Coil Voltage Ranges Controller Catalog Controller Coil Number Prefix Size or Range Rating Volts AC AE16, AE17, AE56, A – F 24 – 240 AE57, CE15, CE55 G – K 48 – 240 L – N 110 – 240 AN16, AN56, CN15, 00 – 0 24 _ 240 CN55 1 – 2 48 – 240 3 110 – 240 CN35 10 – 30A 24 – 240 60A 48 – 240 100A 110 – 240 Table 34-372. Product Selection Coil Catalog Price Voltage Number U.S. $ 6V DC C320DC2V6 9V DC C320DC2V9 12V DC C320DC2V12 24V DC C320DC2V24 48V DC C320DC2V48 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-284 Freedom March 2009 Renewal Parts Table 34-375. For Catalog Numbers AE16, AE17, AE56, AE57, CE15 and CE55 — IEC Frames A – F Description IEC Frames Price IEC Frames Price IEC Frames Price � � A – F U.S. $ A – C U.S. $ D – F U.S. $ Series A1 Series B1 Series C1 Series B1 Series C1 Part No. Part No. Part No. Part No. Part No. Renewal Parts Publication Number None None None None None Contact Kits 34 � � � � � 2-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . � � � � � 3-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . � � � � � 4-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . � � � � � 5-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Magnet Coils Coil Suffix 120V 60 Hz or 110V 50 Hz A 9-2650-1 9-2875-1 9-2875-1 9-2876-1 9-2876-1 240V 60 Hz or 220V 50 Hz B 9-2650-2 9-2875-2 9-2875-2 9-2876-2 9-2876-2 480V 60 Hz or 440V 50 Hz C 9-2650-3 9-2875-3 9-2875-3 9-2876-3 9-2876-3 600V 60 Hz or 550V 50 Hz D 9-2650-4 9-2875-4 9-2875-4 9-2876-4 9-2876-4 208V 60 Hz . . . . . . . . . . . . . E 9-2650-5 9-2875-5 9-2875-5 9-2876-5 9-2876-1 277V 60 Hz . . . . . . . . . . . . . H 9-2650-13 9-2875-12 9-2875-12 9-2876-12 9-2876-2 208/240V 60 Hz . . . . . . . . . . J — 9-2875-37 9-2875-37 9-2876-37 9-2876-37 240V 50 Hz . . . . . . . . . . . . . K 9-2650-12 9-2875-11 9-2875-11 9-2876-11 9-2876-3 380 – 415V 50 Hz . . . . . . . . . L 9-2650-6 9-2875-6 9-2875-6 9-2876-6 9-2876-4 24V 60 Hz – 24V 50 Hz T — 9-2875-36 9-2875-36 9-2876-36 9-2876-36 24V 60 Hz . . . . . . . . . . . . . . . T 9-2650-7 — — — — 24V 50 Hz . . . . . . . . . . . . . . . U 9-2650-14 9-2875-13 9-2875-13 9-2876-13 9-2876-13 32V 50 Hz . . . . . . . . . . . . . . . V 9-2650-9 9-2875-16 9-2875-16 9-2876-16 9-2876-16 48V 60 Hz . . . . . . . . . . . . . . . W 9-2650-8 9-2875-8 9-2875-8 9-2876-8 9-2876-8 48V 50 Hz . . . . . . . . . . . . . . . Y 9-2650-10 9-2875-9 9-2875-9 9-2876-9 9-2876-9 Overload Relays For replacement on existing starters: 3-Pole — Ambient Compensated Bimetallic . . . . . . . . . . . . C306DN3B C306DN3B C306DN3B C306DN3B C306DN3B Current Transformer Transformer. . . . . . . . . . . . . . . . . . . . . . . .—— —— — Magnet Frame Armature � � � � � Lower Magnet Frame . . . . . . . . . . . . . . . . � � � � � Upper Magnet Frame . . . . . . . . . . . . . . . . � Non-encapsulated coils. � Replace with complete contactor. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-285 Freedom March 2009 Renewal Parts Note: For a complete listing of parts, refer to the Renewal Parts Publication Number referenced below. Table 34-376. For Catalog Numbers AE16, AE17, AE56, AE57, CE15 and CE55 — IEC Frames G and H Description IEC Frame G Price IEC Frame H Price U.S. $ U.S. $ Series A1 Series B1 Series A1 Series B1 Part No. Part No. Part No. Part No. Renewal Parts Publication Number 20862 22178 20862 22178 Contact Kits 34 2-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-65-3 6-65-3 6-65-5 6-65-5 3-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-65-4 6-65-4 6-65-6 6-65-6 4-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-65-11 6-65-11 6-65-13 6-65-13 5-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-65-12 6-65-12 6-65-14 6-65-14 Magnet Coils Coil Suffix 120V 60 Hz or 110V 50 Hz A 9-2703-1 9-2703-1 9-2703-1 9-2703-1 240V 60 Hz or 220V 50 Hz B 9-2703-2 9-2703-2 9-2703-2 9-2703-2 480V 60 Hz or 440V 50 Hz C 9-2703-3 9-2703-3 9-2703-3 9-2703-3 600V 60 Hz or 550V 50 Hz D 9-2703-4 9-2703-4 9-2703-4 9-2703-4 208V 60 Hz . . . . . . . . . . . . . . E 9-2703-9 9-2703-9 9-2703-9 9-2703-9 277V 60 Hz . . . . . . . . . . . . . . H 9-2703-7 9-2703-7 9-2703-7 9-2703-7 240V 50 Hz . . . . . . . . . . . . . . K 9-2703-14 9-2703-14 9-2703-14 9-2703-14 380 – 415V 50 Hz . . . . . . . . . L 9-2703-8 9-2703-8 9-2703-8 9-2703-8 24V 60 Hz – 24V 50 Hz T — — — — 24V 60 Hz . . . . . . . . . . . . . . . T 9-2703-6 9-2703-6 9-2703-6 9-2703-6 24V 50 Hz . . . . . . . . . . . . . . . U 9-2703-12 9-2703-12 9-2703-12 9-2703-12 32V 50 Hz . . . . . . . . . . . . . . . V 9-2703-10 9-2703-10 9-2703-10 9-2703-10 48V 60 Hz . . . . . . . . . . . . . . . W 9-2703-11 9-2703-11 9-2703-11 9-2703-11 48V 50 Hz . . . . . . . . . . . . . . . Y 9-2703-13 9-2703-13 9-2703-13 9-2703-13 Overload Relays For replacement on existing starters: 3-Pole — Ambient Compensated Bimetallic . . . . . . . . . . . . C306GN3B C306GN3B C306GN3B C306GN3B Current Transformer Transformer . . . . . . . . . . . . . . . . . . . . . . . .—— —— Magnet Frame Armature Lower Magnet Frame . . . . . . . . . . . . . . . . 17-18200 17-18200 17-18200 17-18200 Upper Magnet Frame . . . . . . . . . . . . . . . . 48-1936 48-1936 48-1936 48-1936 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-286 Freedom March 2009 Renewal Parts Note: For a complete listing of parts, refer to the Renewal Parts Publication Number referenced below. Table 34-377. For Catalog Numbers AE16, AE17, AE56, AE57, AE800, CE15 and CE55 — IEC Frames J and K Description IEC Frame J Price IEC Frame K Price U.S. $ U.S. $ Series A1 Series B1 Series A1 Series B1 Part No. Part No. Part No. Part No. Renewal Parts Publication Number 20862 22178 20862 22178 Contact Kits 34 2-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-65-7 6-65-7 6-65-18 6-65-18 3-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-65-8 6-65-8 6-65-19 6-65-19 4-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-65-15 6-65-15 — — 5-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-65-16 6-65-16 — — Magnet Coils Coil Suffix 120V 60 Hz or 110V 50 Hz A 9-2703-1 9-2703-1 9-2703-1 9-2703-1 240V 60 Hz or 220V 50 Hz B 9-2703-2 9-2703-2 9-2703-2 9-2703-2 480V 60 Hz or 440V 50 Hz C 9-2703-3 9-2703-3 9-2703-3 9-2703-3 600V 60 Hz or 550V 50 Hz D 9-2703-4 9-2703-4 9-2703-4 9-2703-4 208V 60 Hz . . . . . . . . . . . . . E 9-2703-9 9-2703-9 9-2703-9 9-2703-9 277V 60 Hz . . . . . . . . . . . . . H 9-2703-7 9-2703-7 9-2703-7 9-2703-7 240V 50 Hz . . . . . . . . . . . . . K 9-2703-14 9-2703-14 9-2703-14 9-2703-14 380 – 415V 50 Hz . . . . . . . . . L 9-2703-8 9-2703-8 9-2703-8 9-2703-8 24V 60 Hz – 24V 50 Hz T — — — — 24V 60 Hz . . . . . . . . . . . . . . . T 9-2703-6 9-2703-6 9-2703-6 9-2703-6 24V 50 Hz . . . . . . . . . . . . . . . U 9-2703-12 9-2703-12 9-2703-12 9-2703-12 32V 50 Hz . . . . . . . . . . . . . . . V 9-2703-10 9-2703-10 9-2703-10 9-2703-10 48V 60 Hz . . . . . . . . . . . . . . . W 9-2703-11 9-2703-11 9-2703-11 9-2703-11 48V 50 Hz . . . . . . . . . . . . . . . Y 9-2703-13 9-2703-13 9-2703-13 9-2703-13 Overload Relays For replacement on existing starters: 3-Pole — Ambient Compensated Bimetallic . . . . . . . . . . . . C306GN3B C306GN3B C306GN3B C306GN3B Current Transformer Transformer. . . . . . . . . . . . . . . . . . . . . . . .—— —— Magnet Frame Armature Lower Magnet Frame . . . . . . . . . . . . . . . . 17-18200 17-18200 17-18200 17-18200 Upper Magnet Frame . . . . . . . . . . . . . . . . 48-1936 48-1936 48-1936 48-1936 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-287 Freedom March 2009 Renewal Parts Note: For a complete listing of parts, refer to the Renewal Parts Publication Number referenced below. Table 34-378. For Catalog Numbers AE16, AE17, AE56, AE57, AE800, CE15 and CE55 — IEC Frames L – N Description IEC Frame L Price IEC Frame M Price IEC Frame N Price U.S. $ U.S. $ U.S. $ Part No. Part No. Part No. Renewal Parts Publication Number 20427 20427 20427 Contact Kits 2-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-43-3 6-43 6-43-5 34 3-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-43-4 6-43-2 6-43-6 4-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . — — — 5-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . — — — Magnet Coils Coil Suffix 120V 60 Hz or 110V 50 Hz A 9-2756-1 9-2756-1 9-2756-1 240V 60 Hz or 220V 50 Hz B 9-2756-2 9-2756-2 9-2756-2 480V 60 Hz or 440V 50 Hz C 9-2756-3 9-2756-3 9-2756-3 600V 60 Hz or 550V 50 Hz D 9-2756-4 9-2756-4 9-2756-4 208V 60 Hz . . . . . . . . . . . . . . E 9-2756-5 9-2756-5 9-2756-5 277V 60 Hz . . . . . . . . . . . . . . H 9-2756-9 9-2756-9 9-2756-9 240V 50 Hz . . . . . . . . . . . . . . K 9-2756-13 9-2756-13 9-2756-13 380 – 450V 50 Hz . . . . . . . . . L — — — 340V 60 Hz . . . . . . . . . . . . . . L 9-2756-12 9-2756-12 9-2756-12 415V 60 Hz . . . . . . . . . . . . . . M 9-2756-8 9-2756-8 9-2756-8 550V 50 Hz . . . . . . . . . . . . . . N 9-2756-14 9-2756-14 9-2756-14 24V 60 Hz – 24V 50 Hz T — — — 24V 60 Hz . . . . . . . . . . . . . . . T 9-2756-6 9-2756-6 9-2756-6 24V 50 Hz . . . . . . . . . . . . . . . U 9-2756-11 9-2756-11 9-2756-11 32V 50 Hz . . . . . . . . . . . . . . . V 9-2756-10 9-2756-10 9-2756-10 48V 60 Hz . . . . . . . . . . . . . . . W 9-2756-15 9-2756-15 9-2756-15 48V 50 Hz . . . . . . . . . . . . . . . Y 9-2756-7 9-2756-7 9-2756-7 Overload Relays For replacement on existing starters: 3-Pole — Ambient Compensated Bimetallic . . . . . . . . . . . . 10-6530 10-6530-2 10-6530-3 Current Transformer Transformer . . . . . . . . . . . . . . . . . . . . . . . .——— Magnet Frame Armature Lower Magnet Frame . . . . . . . . . . . . . . . . 17-8955-2 17-8955-2 17-8955-2 Upper Magnet Frame . . . . . . . . . . . . . . . . 48-1902 48-1902 48-1902 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-288 Freedom March 2009 Renewal Parts Note: For a complete listing of parts, refer to the Renewal Parts Publication Number referenced below. Table 34-379. For Catalog Number CE15 Contactors — IEC Frames P – S Description IEC Frame P Price IEC Frame R Price IEC Frame S Price U.S. $ U.S. $ U.S. $ Part No. Part No. Part No. Renewal Parts Publication Number 22278 22278 22278 Contact Kits Size 6-294 6-288 6-286 Magnet Coils Coil Suffix 34 120V 60 Hz or 110V 50 Hz. . . . A 9-1891-1 9-1891-1 9-1891-1 200V 50 Hz or 118V 60 Hz. . . . E — — — 240V 60 Hz or 220V 50 Hz. . . . B 9-1891-2 9-1891-2 9-1891-2 254V 50 Hz or 277V 60 Hz. . . . H — — — 380V 50 Hz or 415V 60 Hz. . . . L — — — 480V 60 Hz or 440V 50 Hz. . . . C 9-1891-3 9-1891-3 9-1891-3 600V 60 Hz or 550V 50 Hz. . . . D 9-1891-4 9-1891-4 9-1891-4 208V 60 Hz . . . . . . . . . . . . . . . E 9-1891-13 9-1891-13 9-1891-13 277V 60 Hz . . . . . . . . . . . . . . . H 9-1891-26 9-1891-26 9-1891-26 240V 50 Hz . . . . . . . . . . . . . . . K 9-1891-20 9-1891-20 9-1891-20 380V 50 Hz . . . . . . . . . . . . . . . L 9-1891-14 9-1891-14 9-1891-14 415V 50 Hz . . . . . . . . . . . . . . . M 9-1891-21 9-1891-21 9-1891-21 24V 60 Hz . . . . . . . . . . . . . . . . . T 9-1891-15 9-1891-15 9-1891-15 Overload Relays — Reference C316 Overload Relays Magnet Frame Armature Lower Magnet Frame . . . . . . . . . . . . . . . . . . . . 48-1030 48-1030 48-1030 Upper Magnet Frame . . . . . . . . . . . . . . . . . . . . 48-1029-2 48-1029-2 48-1029-2 Table 34-380. For Catalog Number CE15 Contactors — IEC Frames T – V Description IEC Frame T Price IEC Frame U Price IEC Frame V Price U.S. $ U.S. $ U.S. $ Part No. Part No. Part No. Renewal Parts Publication Number 22275 22276 22586 Contact Kits Size 6-621 6-622 6-601 Magnet Coils Coil Suffix 120V 60 Hz or 110V 50 Hz. . . . A 9-3006 9-3006 9-2698 200V 50 Hz or 118V 60 Hz. . . . E 9-3006-5 9-3006-5 — 240V 60 Hz or 220V 50 Hz. . . . B 9-3006-2 9-3006-2 9-2698-2 254V 50 Hz or 277V 60 Hz. . . . H 9-3006-6 9-3006-6 9-2698-2 380V 50 Hz or 415V 60 Hz. . . . L 9-3006-7 9-3006-7 9-2698-6 480V 60 Hz or 440V 50 Hz. . . . C 9-3006-3 9-3006-3 9-2698-3 600V 60 Hz or 550V 50 Hz. . . . D 9-3006-4 9-3006-4 9-2698-4 208V 60 Hz . . . . . . . . . . . . . . . E — — 9-2698-5 277V 60 Hz . . . . . . . . . . . . . . . H — — — 240V 50 Hz . . . . . . . . . . . . . . . K — — — 380V 50 Hz . . . . . . . . . . . . . . . L — — — 415V 50 Hz . . . . . . . . . . . . . . . M — — — 24V 60 Hz . . . . . . . . . . . . . . . . . T — — — Overload Relays — Reference C316 Overload Relays Magnet Frame Armature Lower Magnet Frame . . . . . . . . . . . . . . . . . . . . — — — Upper Magnet Frame . . . . . . . . . . . . . . . . . . . . — — — � Feeder Group Renewal Volts Hertz IEC Size T Price U.S. $ IEC Size U Price U.S. $ IEC Size V Price U.S. $ Series A1 Series A1 Series A1 Series B1 Series B1 Series B1 110 – 120 50/60 9-3007 9-3007 9-2705 220 – 240 50/60 9-3007-2 9-3007-2 9-2705-2 440 – 480 50/60 9-3007-3 9-3007-3 9-2705-3 550 – 600 50/60 9-3007-4 9-3007-4 9-2705-4 208 50/60 9-3007-5 9-3007-5 9-2705-5 380 – 415 50/60 9-3007-7 9-3007-7 9-2705-6 48 – 52 50/60 9-3007-6 9-3007-6 9-2705-8 � Voltage ratings of the main coils must match those of the feeder group for proper operation of the starter/contactor. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-289 Freedom March 2009 Renewal Parts Note: For a complete listing of parts, refer to the Renewal Parts Publication Number referenced below. Table 34-381. For Catalog Number CE15 Contactors — IEC Frames W – Z Description IEC Frame W Price IEC Frame X Price IEC Frame Z Price U.S. $ U.S. $ U.S. $ Part No. Part No. Part No. Renewal Parts Publication Number 22586 — 22586 Contact Kits Size 6-601 6-613 6-571 Magnet Coils Coil Suffix 34 120V 60 Hz or 110V 50 Hz . . . . A 9-2698 9-2698 9-2654 200V 50 Hz or 118V 60 Hz. . . . E — — — 240V 60 Hz or 220V 50 Hz . . . . B 9-2698-2 9-2698-2 9-2654-2 254V 50 Hz or 277V 60 Hz . . . . H — — — 380V 50 Hz or 415V 60 Hz . . . . L 9-2698-6 9-2698-6 9-2654-5 480V 60 Hz or 440V 50 Hz . . . . C 9-2698-3 9-2698-3 9-2654-3 600V 60 Hz or 550V 50 Hz . . . . D 9-2698-4 9-2698-4 9-2654-4 208V 60 Hz . . . . . . . . . . . . . . . . E 9-2698-5 9-2698-5 9-2654-6 277V 60 Hz . . . . . . . . . . . . . . . . H — — — 240V 50 Hz . . . . . . . . . . . . . . . . K — — — 380V 50 Hz . . . . . . . . . . . . . . . . L — — — 415V 50 Hz . . . . . . . . . . . . . . . . M — — — 24V 60 Hz . . . . . . . . . . . . . . . . T — — — Overload Relays — Reference C316 Overload Relays Magnet Frame Armature Lower Magnet Frame . . . . . . . . . . . . . . . . . . . . — — — Upper Magnet Frame . . . . . . . . . . . . . . . . . . . . — — — � Feeder Group Renewal Volts Hertz IEC Size W Price IEC Size X Price IEC Size Z Price Series A1 U.S. $ Series A1 U.S. $ Series A1 U.S. $ Series B1 Series B1 Series B1 110 – 120 50/60 9-2705 9-2705 9-2664 220 – 240 50/60 9-2705-2 9-2705-2 9-2664-2 440 – 480 50/60 9-2705-3 9-2705-3 9-2664-3 550 – 600 50/60 9-2705-4 9-2705-4 9-2664-4 208 50/60 9-2705-5 9-2705-5 9-2664-6 380 – 415 50/60 9-2705-6 9-2705-6 9-2664-5 48 – 52 50/60 9-2705-8 9-2705-8 — � Voltage ratings of the main coils must match those of the feeder group for proper operation of the starter/contactor. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-290 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Type A302 Manual Motor Protectors Contents Product Description Standards and Certifications ® The Cutler-Hammer A302 from Description Page ■ UL File No. E37316, Category NLRV Eaton’s electrical business is a three- ■ CSA File No. LR12530-67M, Class Manual Motor Protectors phase Manual Motor Protector with an 3211-05 adjustable bimetallic Class 10 thermal Product Description. . . . . . . 34-290 ■ IEC 947-1, IEC 947-2, IEC-947-4 overload and instantaneous magnetic Features . . . . . . . . . . . . . . . . 34-290 short circuit trip mechanism. These 34 Standards and MMPs can be used in single-phase or Certifications . . . . . . . . . . . 34-290 three-phase MMP applications. A302 MMPs are UL listed and CSA certified Instructional Leaflets . . . . . . 34-290 for group installations of motors and Instructional Leaflets Product Selection . . . . . . . . 34-291 single motor installations up to 25 Accessories . . . . . . . . . . . . . 34-292 Pub20560 — A302 Manual Motor FLA. These MMPs can be field wired Protectors for single-phase motor applications by Note: For more information, see connecting the three poles in series. Pub20561 — C320 Auxiliary Contacts CA03801001E. (Side Mount) Pub20562 — C320 Auxiliary Contacts Features (Internal Mount) ■ Compact 45 mm design — saves Pub20563 — C320 Trip Alarm Contact panel space Pub20564 — C320 Indicating Lights ■ Meets UL, CSA and international Pub20566 — C320 Undervoltage standards Module ■ CE Mark Pub20567 — C320 Shunt Trip Module ■ Class 10 bimetallic thermal overload trip Pub20723 — C320 Busbar Accessories ■ Single-phase fault sensitivity Catalog Number Catalog Number ■ Snap-on DIN rail mount capability or A302GN with Side A302KN can be panel mounted with screws Auxiliary Contacts ■ Open MMPs can be padlocked in OFF (STOP) position ■ Terminals are “fingerproof,” located in the vertical plane, easily accessible from the front with screwdriver guide holes provided for ease of wiring ■ Wide range of accessories, includ- ing auxiliary contacts, undervoltage release module and shunt trip can be added to the MMP without tools For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-291 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Type A302 Manual Motor Protectors Product Selection When ordering, specify Catalog Numbers For motors with service factors less For motor with service factor of 1.15 than 1.15, multiply the motor FLA by or greater, use motor nameplate Full according to the following stipulations: .9 to select appropriate A302 MMP. Load Amperes to select the appropriate A302 MMPs are selected based on the Example: For motor having FLA of MMP. Example: For motor having FLA overload current range required for a 6.4A and service factor of 1.0 (6.4A x of 6.4A and service factor of 1.15, select given motor. This current range is .9 = 5.76A) select Catalog Number Catalog Number A302KN. determined from the motor Full Load 34 A302JN. Ampere rating and Motor Service Factor usually found on the motor nameplate. Table 34-382. Product Selection — Type A302 Manual Motor Protector � Adjustable Maximum Single-Phase Maximum 3-Phase Horsepower Group Motor Catalog Price � � Thermal Current Horsepower Applications Number U.S. $ Range (Amperes) 480V Maximum 115V 200V 230V 200V 230V 460V 575V Maximum Fuse or Circuit Breaker Amperes .10 – .16 — — — — — — — 1200 A302AN .16 – .25 — — — — — — — 1200 A302BN .25 – .4 — — — — — — — 1200 A302CN .40 – .63 — — — — — — — 1200 A302DN .63 – 1.0 — — — — — 1/2 1/2 1200 A302EN 1.0 – 1.6 — — 1/10 — — 3/4 1 1200 A302FN 1.6 – 2.5 — 1/8 1/6 1/2 1/2 1 1-1/2 1200 A302GN 2.5 – 4.0 1/8 1/4 1/3 3/4 1 2 3 1200 A302HN 4.0 – 6.3 1/4 1/2 1/2 1-1/2 1-1/2 3 5 1200 A302JN 6.3 – 10.0 1/2 1 1-1/2 2 3 5 7-1/2 1200 A302KN 10.0 – 16.0 1 2 2 3 5 10 10 1200 A302LN 16.0 – 20.0 1-1/2 3 3 5 — — 15 1200 A302MN 20.0 – 25.0 2 — — — 7-1/2 15 20 1200 A302NN � Single-phase horsepower ratings are based on wiring the three MMP poles in series. � Select MMP by full load amperes. Horsepower ratings are for reference only. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-292 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Type A302 Manual Motor Protectors Accessories Table 34-383. Accessories — A302 Description Catalog Price Number U.S. $ Enclosure, Nonmetallic IP41 General Purpose C799MP41 IP55 Dust and Water Protection C799MP55 34 Conversion Kit (Converts IP41 C320MSG1 Enclosure to IP55) Conduit Adapter — To convert C320MSA1 PG16 Metric Threads on C799MP41 and C799MP55 to 1/2" N.P.T. Threads Enclosure, Semimetallic C799MP11 Enclosure with Emergency UL Listed for NEMA 1, 4, 4X, Pushbutton and Indicating Light 12 and 13 Applications Flush Plate (Cavity Mount), Nonmetallic IP41 General Purpose C799FP41 IP55 Dust and Water Protection C799FP55 Conversion Kit (Converts IP41 C320MSG2 Flush Plate to IP55) Emergency Pushbutton — For Enclosures and Flush Plates E Button C320MSE1 E Button Latch — Pull to Release C320MSE2 Enclosure with Padlock Padlock Attachment — For C320MSD Attachment and Indicating Light Enclosures and Flush Plates Red Indicating Light 110/120V C320MSL1A 220/240V C320MSL1B 380/415V C320MSL1L 420/500V C320MSL1C 500/600V C320MSL1D Green Indicating Light 110/120V C320MSL2A 220/240V C320MSL2B 380/415V C320MSL2L 420/500V C320MSL2C 500/600V C320MSL2D Auxiliary Contacts, Side Mounted 1NO-1NC C320MSC3 2NO C320MSC4 1NO-1NC Early Closing C320MSC6 2NO Early Closing C320MSC7 SPDT Logic Level (100 mA, C320MSC3L 30V maximum) A302 MMP with Side Auxiliary Contact Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-293 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Type A302 Manual Motor Protectors Table 34-383. Accessories — A302 (Continued) Description Catalog Price Number U.S. $ Auxiliary Contacts, Internally Mounted C320MSC8 � within MMP Housing 1NO-1NC I (AC-15) = 2A, 230V; 1A, 400V; e .5A, 500V 34 I (DC-15) = .7A, 60V; .55A, 110V; e .25A, 220V Trip Alarm, Internally Mounted within MMP Housing. These contacts change state only when overload trips or short � circuit occurs. 1NO C320MSC1 A302 MMP with Undervoltage 1NC C320MSC2 Release Module Mounted in Base I (AC-15) = 2A, 230V; 1A, 400V; e .5A, 500V I (DC-15) = .7A, 60V; .55A, 110V; e .25A, 220V Shunt Trip, Internally Mounted within � MMP Housing 110/120V C320MST1A 220/240V C320MST1B 380/440V C320MST1L 415/480V C320MST1C 550/600V C320MST1D Undervoltage Release, Internally � 3-Phase Connecting Busbar Mounted within MMP Housing with Terminal Block, Busbar 110/120V C320MSR1A Cover and A302 MMPs 220/240V C320MSR1B 380/440V C320MSR1L 415/480V C320MSR1C 550/600V C320MSR1D 3-Phase Connecting Busbar — Permits quick line side connection of adjacent MMPs (600V, 65A Max.) For Linking 2 MMPs C320MSB1 For Linking 4 MMPs C320MSB2 For Linking 5 MMPs C320MSB3 Terminal Block — Used in conjunction C320MSB4 with 3-Phase Connecting Busbar listed above (600V, 65A Max.) Wire Range: 10 – 6 AWG Combination Adapter Plate with A302 MMP and CE15 Contactor Busbar Cover — Used to cover unused C320MSB10 Busbar Terminals (box of 10 covers) Combination Adapter Plate — C321MSP Permits A302 MMP and magnetic contactor (Cat. No. CE15) to be mounted one above the other. Adapter plate snap mounts to DIN rail. A302 MMP Mounted on DIN Rail 35 mm DIN Rail — 1 Meter Length MC382MA1 � Only one internally mounted accessory can be mounted within MMP housing. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-294 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types A307, A308, A309 Manual Motor Protectors ■ Fixed Short Circuit Trip — 13 times Contents Application Description maximum setting of overload FLA dial Description Page The A307, A308 and A309 MMPs can be used in the following applications: ■ Type 2 Coordination per IEC 947 Manual Motor Protectors ■ Identification Markers Standard on Product Description. . . . . . . 34-294 Manual Motor Protectors Starter Faceplate Application Description. . . . 34-294 All of the MMPs are UL Listed under ■ Motor Applications from 0.11A to UL508 as Manual Motor Controllers. 100A 34 Features . . . . . . . . . . . . . . . . 34-294 They provide an economical solution ■ Built-in heater and magnetic trip Standards and for applications requiring simple man- elements to protect the motor Certifications . . . . . . . . . . . 34-294 ual starting and stopping of motors. ■ Adjustment dial for setting motor Instructional Leaflets . . . . . . 34-294 When used as an MMP, they are FLA typically installed in an enclosure. Product Selection . . . . . . . . 34-295 ■ DIN Rail or Panel Mount IP55 enclosures are offered as acces- Accessories . . . . . . . . . . . . . 34-297 ■ Accessories include: sories for the MMPs. Separate short- circuit protective devices, such as ❑ Front and Side Auxiliary Contacts Note: For more information, see circuit breakers or fuses, are wired ❑ Trip Indicating Contacts CA03801001E. ahead of the MMPs. The short-circuit ❑ Tamperproof Cover for OLR Dial protective device should be sized per the NEC code and should not exceed ❑ Undervoltage Release 400% of the maximum FLA dial setting ❑ Shunt Trip of the MMP. ❑ Thru-the-Door Operators Group Motor Installations ❑ Enclosures ❑ 3-Phase Line Side Connecting A Group Motor Installation can be defined as more than one motor circuit Links protected by a single set of fuses or cir- cuit breaker on a motor branch circuit. Standards and Certifications This eliminates the need for individual fuses or circuit breakers for each ■ UL File No. E176513, Category NKJH motor circuit. Substantial component A307, A308 and A309 (A307, A308, A309) Manual Motor Protectors cost savings, panel space savings and UL File No. E37317, Category NKCR reduced wiring installation time can be (Accessories) achieved in Group Motor Installations. ■ CSA File LR12530, Class 3211-05 Product Description Table 34-384. Short Circuit Ratings ■ IEC 947-1; IEC 947-2; IEC947-4-1 ® The Cutler-Hammer A307, A308 and Description Specification ■ DIN VDE 0660 Part 100, Part 101 and A309 family of Manual Motor Protec- Part 102 UL 508 Type E tors (MMPs) from Eaton’s electrical Manual Combination Starter/Motor Controller business feature a rotary ON/OFF � A307 65 kA @ 240V, 480Y/277V manual disconnect, Class 10 adjust- 30 kA @ 600Y/347V up to 12.5A able bimetallic overload relay and � A308 65 kA @ 240V, 480Y/277V fixed magnetic short circuit trip capa- 25 kA @ 600Y/347V bility in one compact unit. Three � Instructional Leaflets A309 65 kA @ 240V, 480Y/277V frame sizes are available: A307 (45 mm) 30 kA @ 600Y/347V up to 75A for motors with FLA ratings up to 25A, IL49490 — A307 Manual Motor � See Pages 34-295 – 34-296 for individual A308 (55 mm) covers motor FLA ratings Protectors ratings. up to 50A and the A309 (70 mm) is suit- IL49491 — A308 Manual Motor able for motor FLA ratings to 100A. Protectors Features IL49492 — A309 Manual Motor ■ ON/OFF Rotary Handle with Lockout Protectors Provision IL49493 — C320TR11 Trip Indicating ■ Visible Trip Indication Contacts ■ Class 10 Overload Protection IL49494 — IP55 Enclosures and Front ■ Phase Loss Sensitivity Plates ■ Ambient Temperature Compensation IL49495 — C320HN Thru-the-Door to 140°F Operators IL49496 — Indicating Lights See Application Note — AP03402001E. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-295 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types A307, A308, A309 Manual Motor Protectors Product Selection Product Selection for Group Motor Installations When ordering, specify Catalog Numbers For motors with service factors less than 1.15, multiply the motor FLA by according to the following stipulations: .92 to select appropriate MMP. A307, A308 and A309 Manual Motor Protectors are selected based on the 34 Example: For motor having FLA overload current range required for a of 6.4A and service factor of 1.0 given motor. This current range is (6.4A x .92 = 5.88A) select Catalog determined from the motor Full Load Number A307TN. A307 Ampere rating and Motor Service Factor See Application Note — AP03402001E. usually found on the motor nameplate. Table 34-385. Group Motor Installations � FLA Single-Phase Three-Phase hp Ratings Maximum Catalog Price � Adjustment hp Ratings Short Circuit Number U.S. $ Range Current Rating 115V 230V 200V 230V 460V 575V 460V 600V A307 0.11 – 0.16 — — — — — — 65 kA 30 kA A307AN 0.14 – 0.2 — — — — — — 65 kA 30 kA A307BN 0.18 – 0.25 — — — — — — 65 kA 30 kA A307CN 0.22 – 0.32 — — — — — — 65 kA 30 kA A307DN 0.28 – 0.4 — — — — — — 65 kA 30 kA A307EN 0.35 – 0.5 — — — — — — 65 kA 30 kA A307FN 0.45 – 0.63 — — — — — — 65 kA 30 kA A307GN 0.55 – 0.8 — — — — — 1/2 65 kA 30 kA A307HN A308 0.7 – 1 — — — — 1/2 1/2 65 kA 30 kA A307JN 0.9 – 1.25 — — — — 3/4 3/4 65 kA 30 kA A307KN 1.1 – 1.6 — — — — 3/4 1 65 kA 30 kA A307LN 1.4 – 2 — — — — 1 1-1/2 65 kA 30 kA A307MN 1.8 – 2.5 — 1/6 1/2 1/2 1-1/2 1-1/2 65 kA 30 kA A307NN 2.2 – 3.2 — 1/4 3/4 3/4 1-1/2 2 65 kA 30 kA A307PN 2.8 – 4 — 1/3 3/4 1 2 3 65 kA 30 kA A307RN 3.5 – 5 1/6 1/2 1 1 3 3 65 kA 30 kA A307SN 4.5 – 6.3 1/4 3/4 1-1/2 1-1/2 5 5 65 kA 30 kA A307TN 5.5 – 8 1/3 1 2 2 5 5 65 kA 30 kA A307UN 7 . – 10 1/2 1-1/2 3 3 7-1/2 10 65 kA 30 kA A307VN 9 – 12.5 1/2 2 3 3 7-1/2 10 65 kA 30 kA A307WN 11 – 16 1 3 5 5 10 15 65 kA 10 kA A307XN 14 – 20 1-1/2 3 5 7-1/2 15 20 65 kA 10 kA A307YN 17 – 22 2 3 7-1/2 7-1/2 15 20 65 kA 10 kA A307ZN 20 – 25 2 5 7-1/2 7-1/2 15 20 65 kA 10 kA A307Z25N A308 11 – 16 1 3 5 5 10 15 65 kA 25 kA A308LN 14 – 20 1-1/2 3 5 7-1/2 15 20 65 kA 25 kA A308MN A309 18 – 25 2 5 7-1/2 10 20 25 65 kA 25 kA A308NN 22 – 32 3 5 10 10 25 30 65 kA 25 kA A308PN 28 – 40 3 7-1/2 15 15 30 40 65 kA 25 kA A308RN For motor with service factor of 1.15 36 – 45 5 7-1/2 15 15 30 40 65 kA 25 kA A308SN 40 – 50 5 10 15 20 40 50 65 kA 25 kA A308TN or greater, use motor nameplate Full Load Amperes to select the appropriate A309 MMP. 28 – 40 3 7-1/2 15 15 30 40 65 kA 30 kA A309RN 36 – 50 5 10 15 20 40 50 65 kA 30 kA A309SN Example: For motor having FLA of 45 – 63 5 15 20 25 50 60 65 kA 30 kA A309TN 6.4A and service factor of 1.15, select 57 – 75 7-1/2 15 25 25 60 75 65 kA 30 kA A309UN Catalog Number A307UN. 70 – 90 10 20 30 30 75 100 65 kA 10 kA A309VN 80 – 100 10 25 40 40 75 100 65 kA 10 kA A309WN � Select Manual Motor Protectors for use with group motor installations by full load amperes. Horsepower ratings are for reference only. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-296 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types A307, A308, A309 Manual Motor Protectors Product Selection for UL 508 Type E Self-Protected Manual Combination Starter Applications For motors with service factors less When ordering, specify Catalog Numbers than 1.15, multiply the motor FLA by according to the following stipulations: .92 to select appropriate MMP. A307, A308 and A309 Manual Motor Protectors are selected based on the Example: For motor having FLA overload current range required for a of 6.4A and service factor of 1.0 34 given motor. This current range is (6.4A x .92 = 5.88A) select Catalog determined from the motor Full Load Number A307TN. Ampere rating and Motor Service Factor A307 usually found on the motor nameplate. See Application Note — AP03402001E. Table 34-386. UL 508 Type E Self-Protected Manual Combination Starters � FLA Single-Phase Three-Phase hp Ratings Maximum Catalog Price � Adjustment hp Ratings Short Circuit Number U.S. $ Range Current Rating 115V 230V 200V 230V 460V 575V 240V 600Y/ 480Y/ 347V 277V A307 � 0.11 – 0.16 — — — — — — 65 kA 30 kA A307AN � 0.14 – 0.2 — — — — — — 65 kA 30 kA A307BN � 0.18 – 0.25 — — — — — — 65 kA 30 kA A307CN � 0.22 – 0.32 — — — — — — 65 kA 30 kA A307DN � 0.28 – 0.4 — — — — — — 65 kA 30 kA A307EN � 0.35 – 0.5 — — — — — — 65 kA 30 kA A307FN � 0.45 – 0.63 — — — — — — 65 kA 30 kA A307GN � 0.55 – 0.8 — — — — — 1/2 65 kA 30 kA A307HN A308 � 0.7 – 1 — — — — 1/2 1/2 65 kA 30 kA A307JN � 0.9 – 1.25 — — — — 3/4 3/4 65 kA 30 kA A307KN � 1.1 – 1.6 — — — — 3/4 1 65 kA 30 kA A307LN � 1.4 – 2 — — — — 1 1-1/2 65 kA 30 kA A307MN � 1.8 – 2.5 — 1/6 1/2 1/2 1-1/2 1-1/2 65 kA 30 kA A307NN � 2.2 – 3.2 — 1/4 3/4 3/4 1-1/2 2 65 kA 30 kA A307PN � 2.8 – 4 — 1/2 3/4 1 2 3 65 kA 30 kA A307RN � 3.5 – 5 1/6 1/2 1 1 3 3 65 kA 30 kA A307SN � 4.5 – 6.3 1/4 3/4 1-1/2 1-1/2 5 5 65 kA 30 kA A307TN � 5.5 – 8 1/3 1 2 2 5 5 65 kA 30 kA A307UN � 7 . – 10 1/2 1-1/2 3 3 7-1/2 10 65 kA 30 kA A307VN � 9 – 12.5 1/2 2 3 3 7-1/2 10 65 kA 30 kA A307WN � 11 – 16 1 3 5 5 10 15 65 kA 10 kA A307XN � 14 – 20 1-1/2 3 5 7-1/2 15 20 65 kA 10 kA A307YN � 17 – 22 2 3 7-1/2 7-1/2 15 20 65 kA 10 kA A307ZN � A308 11 – 16 1 3 5 5 10 15 65 kA 25 kA A308LN 14 – 20 1-1/2 3 5 7-1/2 15 20 65 kA 25 kA A308MN 18 – 25 2 5 7-1/2 10 20 25 65 kA 25 kA A308NN A309 22 – 32 3 5 10 10 25 30 65 kA 25 kA A308PN 28 – 40 3 7-1/2 15 15 30 40 65 kA 25 kA A308RN 36 – 45 5 7-1/2 15 15 30 40 65 kA 25 kA A308SN 40 – 50 5 10 15 20 40 50 65 kA 25 kA A308TN For motor with service factor of 1.15 A309 or greater, use motor nameplate Full � 28 – 40 3 7-1/2 15 15 30 40 65 kA 30 kA A309RN Load Amperes to select the appropriate � 36 – 50 5 10 15 20 40 50 65 kA 30 kA A309SN MMP. � 45 – 63 5 15 20 25 50 60 65 kA 30 kA A309TN � 57 – 75 7-1/2 15 25 25 60 75 65 kA 30 kA A309UN Example: For motor having FLA of � 70 – 90 10 20 30 30 75 100 65 kA 10 kA A309VN 6.4A and service factor of 1.15, select � 80 – 100 10 25 40 40 75 100 65 kA 10 kA A309WN Catalog Number A307UN. � A C320LSA1 Line Side Adapter is required to be installed on the line side of all A307 MMPs when they are used as non-Group Installation Self-Protected Manual Combination Starters. See Page 34-299. � A C320LSA2 Line Side Adapter is required to be installed on the line side of all A309 MMPs when they are used as non-Group Installation Self-Protected Manual Combination Starters. See Page 34-299. � Select UL 508 Type Manual Combination Starter by full load amperes. Horsepower ratings are for reference only. � A308 MMPs do not require Line Side Adapters. Note: A UL 508 Type F Combination Motor Controller consists of a UL 508 Type E Self- protected Manual Combination Starter, a UL Listed Contactor and a UL Listed Line Side Adapter (depending on the application). The Type E Self-Protected Manual Combination Starter alone is a legitimate short-circuit protective device and disconnect means for the downstream motor, Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1 while the contactor has been added to provide remote operation of the motor circuit. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-297 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types A307, A308, A309 Manual Motor Protectors Accessories Table 34-387. Accessories Description Catalog Price Number U.S. $ � Front Mount Auxiliary Contact Blocks (Carton Quantity = 10 pcs.) (For use with A307, A308 or A309 MMP. One block per MMP.) 1 SPDT Contact, NO/NC C320FDC11 1NO and 1NC C320FMC11 34 1 SPDT Contact, NO/NC (Electronic Contact). For use in dusty applications and electronic C320FEC11 circuits with rated operational current Ie/AC-15 and DC-13 from 1 to 300 mA at 3 to 60V. Side Mount Auxiliary Contact Blocks (Carton Quantity = 2 pcs.) (One block per MMP. Mounts to left side of A307, A308 or A309.) 1NO and 1NC C320SA11 2NO C320SA20 2NC C320SA02 Trip Indicating Contacts — Side Mount (One block per MMP. Mounts to left side of A307, A308 or A309. Can also be used with side mount auxiliary contact.) 1NO and 1NC for Any Trip (overload or short-circuit), plus C320TR11 1NO and 1NC for Short-Circuit Trip Only Overload Dial Tamperproof Covers (Carton Quantity = 10 pcs.) C320CD1 (For sealing the FLA adjustment dial or A307, A308 or A309 MMPs.) (10 covers per bag. Price is for one bag.) Undervoltage Release (One release module per MMP. Mounts to right side of A307, A308 or A309. Can not be used with shunt trip.) 120V 60 Hz; 110V 50 Hz C320UR120 240V 60 Hz; 220V 50 Hz C320UR240 400V 50 Hz C320UR400 480V 60 Hz C320UR480 Undervoltage Release with Early Make Contacts (One release module per MMP. Mounts to right side of A307, A308 or A309. Can not be used with shunt trip.) 230V 50 Hz C320URE240 400V 50 Hz C320URE400 480V 60 Hz C320URE480 Shunt Trip (One trip module per MMP. Mounts to right side of A307, A308 or A309. Can not be used with undervoltage release.) AC 50/60 Hz AC 50/60 Hz; DC (100% ON) (5 Seconds ON) 20 – 24V 20 – 70V C320SH24 90 – 110V 70 – 190V C320SH120 210 – 240V 190 – 330V C320SH240 350 – 415V 330 – 500V C320SH480 500V — C320SH500 Thru-the-Door Operator (Type 12, Rated IP65; Rotary Operator Mechanism, lockable with up to 3 padlocks in the OFF position. Includes extension shaft, connecting element and supporting bracket [330 mm depth only] to MMP.) Black Handle — 150 mm Depth C320HNB1 — 330 mm Depth (Includes supporting bracket) C320HNB10 Red Handle and Yellow Background — 150 mm Depth C320HNR1 — 330 mm Depth (Includes supporting bracket) C320HNR10 Terminal Cover for Box Terminals, 50A A308 MMP C320CT50 Terminal Cover for Box Terminals, 100A A309 MMP C320CT100 Terminal Cover for Cable Lug and Busbar Connection, 100A A309 MMP C320CT110 � Consult sales office for MMP and auxiliary contact Series compatibility information. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-298 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types A307, A308, A309 Manual Motor Protectors Table 34-387. Accessories (Continued) Description Catalog Price Number U.S. $ Three-Phase, Line Side Feeder Connecting Links For 2 A307 MMPs, 45 mm Spacing, 63A Maximum C320BUS22 For 3 A307 MMPs, 45 mm Spacing, 63A Maximum C320BUS23 For 4 A307 MMPs, 45 mm Spacing, 63A Maximum C320BUS24 For 5 A307 MMPs, 45 mm Spacing, 63A Maximum C320BUS25 34 For 2 A307 MMPs, with Side Mount Accessories, 55 mm Spacing, 63A Maximum C320BUS26 For 4 A307 MMPs, with Side Mount Accessories, 55 mm Spacing, 63A Maximum C320BUS27 For 2 A307 MMPs, with Side Mount Accessories, 63 mm Spacing, 63A Maximum C320BUS28 For 4 A307 MMPs, with Side Mount Accessories, 63 mm Spacing, 63A Maximum C320BUS29 Three-Phase, Line Side Feeder Lug C320BUS20 (For use with A307 MMP and Line Side Feeder Connecting Links) Three-Phase, Line Side Feeder Lugs C320BUS21 (For connection to bottom of Line Side Feeder Connecting Link instead of MMP) Cover C320BUS19 (For Unused Line Side Feeder Connecting Links) Three-Phase, Line Side Feeder Connecting Links For 2 A308 MMPs, 55 mm Spacing, 100A Maximum C320BUS32 For 3 A308 MMPs, 55 mm Spacing, 100A Maximum C320BUS33 For 4 A308 MMPs, 55 mm Spacing, 100A Maximum C320BUS34 For 2 A308 MMPs, with Side Mount Accessories, 75 mm Spacing, 100A Maximum C320BUS35 For 3 A308 MMPs, with Side Mount Accessories, 75 mm Spacing, 100A Maximum C320BUS36 For 4 A308 MMPs, with Side Mount Accessories, 75 mm Spacing, 100A Maximum C320BUS37 Three-Phase, Line Side Feeder Lug C320BUS31 (For use with A308 MMP and Line Side Feeder Connecting Links) Cover C320BUS30 (For Unused Line Side Feeder Connecting Links) IP55 Nonmetallic Enclosure (Narrow) (For use with A307 MMP and Accessories with a maximum width of 54 mm) Black Handle C799EMB55 Red/Yellow Handle C799EMR55 Note: Enclosures will not accept A307 MMP with Side Mounted Trip Indicating Contact Module (C320TR11) IP55 Nonmetallic Enclosure (Wide) (For use with A307 MMP and Accessories with a maximum width of 72 mm) Black Handle C799WEB55 Red/Yellow Handle C799WER55 Note: Enclosures will not accept A307 MMP with Side Mounted Trip Indicating Contact Module (C320TR11) IP55 Nonmetallic Enclosure (Wide) (For use with A308 MMP and Accessories with a maximum width of 82 mm) Black Handle C799WGB55 Red/Yellow Handle C799WGR55 Note: Enclosures will not accept A308 MMP with Side Mounted Trip Indicating Contact Module (C320TR11) IP55 Nonmetallic Flush Mount Plate (For use with A307 MMP and Accessories with a maximum width of 72 mm) Black Handle C799WFB55 Red/Yellow Handle C799WFR55 Note: Flush Plates will not accept A307 MMP with Side Mounted Trip Indicating Contact Module (C320TR11) IP55 Front Plate (For A307, A308 or A309) Black Handle C799FNB55 Red/Yellow Handle C799FNR55 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-299 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types A307, A308, A309 Manual Motor Protectors Table 34-387. Accessories (Continued) Description Catalog Price Number U.S. $ Pilot Lights for All Enclosures (With Lamp and Red, Green and Clear Colored Lenses) 110 – 120V C320LT120 220 – 240V C320LT240 380 – 415V C320LT415 34 480 – 500V C320LT500 Push-In Mounting Holes C321MH1 (For screw panel mounting of A307 MMP) Carton Qty: 10 Line Side Adapter for A307 MMPs C320LSA1 (Required for use with A307 MMPs only when used as Self-Protected Manual Combination Starters) UL 508 Type E. Not required for Group Installation. � Line Side Adapter for A309 MMPs C320LSA2 (Required for use with A309 MMPs only when used as Self-Protected Manual Combination Starters) UL 508 Type E. Not required for Group Installation. Wiring Connector Link C320WC25 (Electrical and mechanical interconnection between A307 MMP + CE12 Freedom Miniature FVNR Contactor) Wiring Connector Link C320WC45 (Electrical and mechanical interconnection between A307 MMP + CE15 Freedom 45 mm IEC FVNR Contactor — Sizes A – F) Wiring Connector Link C320WC65 (Electrical and mechanical interconnection between A308 MMP + CE15 Freedom 65 mm IEC FVNR Contactor — Sizes G – K) Wiring Connector Link C320WC27 (Electrical and mechanical interconnection between A307 MMP + IT. 27 mm FVNR/FVR Contactor) Wiring Connector Link C320WC45IT (Electrical and mechanical interconnection between A307 MMP + IT. 45 mm FVNR Contactor) Wiring Connector Link C320WC54 (Electrical and mechanical interconnection between A308 MMP + IT. 54 mm FVNR Contactor) � A308 MMP does not require a Line Side Adapter. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-300 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers ■ Group Motor Installations — Since ■ AC and DC coils offered in a variety Contents the Manual Motor Protectors (Man- of voltages Description Page ual Combination Starters) are UL ■ 1NO and 1NC auxiliary contacts listed for Group Motor Installations, front mounted on MMP — Freedom IEC Combination the IEC Combination Motor Control- standard on all combination Motor Controllers lers provide a compact, assembled motor controllers Product Selection . . . . . . . . 34-301 package for Group Motor Installa- ■ 1NO auxiliary contact — standard Accessories . . . . . . . . . . . . . 34-307 tions up to 480V. on all magnetic contactors 34 Dimensions . . . . . . . . . . . . . 34-308 For Group Installations or UL 508 ■ DIN rail or panel mount — Type E/F applications, the A307, A308 Note: For more information, see AE317, AM317 and AM357 motor and A309 Manual Motor Protectors CA03801001E. controllers have a maximum 600Y/347V rating. ■ Mounting plates — standard on For Group Installations (in-panel AE318, AE319, AE358 and AE359 SCPD) applying the traditional 1/3 tap motor controllers rule, Freedom Combination Motor ■ Adjustment dial for setting motor FLA Controllers may be used on 480V Delta ■ Short circuit trip at 13 times the systems. For Group Installations, maximum setting of the FLA applying the more recent 1/10 tap adjustment dial conductor rule, a maximum 240V Delta is permitted or 480Y/277V. Standards and Certifications For actual UL 508 Type E/F applications ■ IEC Type 2 Approved per (out-of-panel upstream feeder SCPD IEC 60947-4-1 only), the Freedom CMCs may be used on a maximum 240V Delta or 480Y/ ■ UL Listed File No. E218618 AE317 Freedom IEC Open Non-reversing Combination Motor Controller 277V system. ■ CE Mark For Manual “At Motor” Disconnect applications, a maximum 240V Delta is Product Description permitted or 480Y/277V and 600Y/347V ® The new Cutler-Hammer Freedom slash rated Wye systems. Instructional Leaflets IEC Open Non-reversing and Revers- ing Combination Motor Controllers Features IL49490 A307 Manual Motor from Eaton’s electrical business Protector ■ ON/OFF rotary handle with lockout combine a Manual Motor Protector IL49491 A308 Manual Motor provision with an IEC Contactor(s) to provide a Protector ■ Visible trip indication complete motor protection solution by IL49492 A309 Manual Motor ■ Test trip function combining motor disconnect function, Protector ■ Motor applications from 0.11A to thermal overload protection, mag- Pub50278 Non-reversing AM317, 100A netic short circuit protection and AE317 & AE318 ■ Class 10 overload protection Combination Motor remote control operation in one com- ■ Built-in heater and magnetic trip Controller, AC Coils pact, assembled unit. These assem- elements to protect the motor Pub50279 Reversing AE357 & bled Combination Motor Controllers ■ Phase loss sensitivity AE358 Combination cover motors with FLA ratings from ■ Type 2 coordination Motor Controllers, AC 0.11A to 100A. ■ Ambient compensated up to Coils 140°F (60° C) Pub50280 Reversing AM357 Application Description ■ High Fault Short Circuit Ratings: Combination Motor ❑ 65 kA at 480V for AE317/357, The Freedom IEC Non-reversing Controllers, AM317/357 and AE318/358 motor AC & DC Coils and Reversing Combination Motor controllers Controllers can be used in the follow- Pub50281 Non-reversing AM317, ❑ 50 kA at 480V for AE319/359 AE317, & AE318 ing applications: motor controllers Combination Motor ■ Combination Motor Controller (UL Controllers, DC Coils Table 34-388. Short Circuit Ratings — UL 508 508, Type F), for Single and Multi Pub50342 Non-reversing AE319 Type E Manual Combination Starter/Motor Motor Panels — The IEC Combination Motor Controller Combination Motor Controllers Controllers, AC & DC Description Specification combine a Manual Motor Protector Coils � with an IEC Contactor. The A307, A307 65 kA @ 240V, 480Y/277V Pub50343 Reversing AE359 A308, and A309 Manual Motor 30 kA @ 600Y/347V up to 12.5A Combination Motor � Protectors are UL listed as UL 508, Controllers, AC & DC A308 65 kA @ 240V, 480Y/277V Type E Self-Protected Manual 25 kA @ 600Y/347V Coils � Combination Starters. This UL Pub50417 Reversing AE357 & A309 65 kA @ 240V, 480Y/277V listing allows these devices to be 30 kA @ 600Y/347V up to 75A AE358 Combination � Motor Controllers, DC used in motor circuits without See Pages 34-295 – 34-296 for individual Coils having to add separate branch short ratings. Pub50545 Wire Connector Link circuit protection with a Line Side ■ Magnet coil terminals located at Installation Adapter. An IEC magnetic contactor bottom of Contactor for easy access AP03402001E Application Note has been added to provide remote and wiring operation of the motor circuit. For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-301 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers For use as CMCs in Group Installation ■ For motors with service factors less Product Selection or UL 508 Type F applications. than 1.15, multiply the motor FLA by .92 to select the appropriate motor When Ordering Specify — controller. Example: For a motor ■ Select required assembled motor having FLA of 6.4A and a service controller by Catalog Number from factor of 1.0 (6.4A x .92 = 5.88A) Table 34-389 and replace underscore select Catalog Number (_) in the Catalog Number with the AM317TNS3_. 34 proper Magnetic Coil Code Suffix ■ For motors with service factor of Letter from Table 34-390. 1.15 or greater, use motor name- ■ All Non-reversing and Reversing plate Full Load Amperes to select motor controllers are selected based the appropriate motor controller. on the overload current range Example: For motor having FLA of required for a given motor. This cur- 6.4A and service factor of 1.15, rent range is determined from the select Catalog Number motor Full Load Ampere rating and AM317UNS3_. Motor Service Factor usually found Instructional Leaflets on the motor nameplate. AM317 — Miniature Freedom IEC See Page 34-300 for Listing. Open Non-reversing Combination Motor Controller Table 34-389. Freedom IEC Open Non-reversing Combination Motor Controllers (A307 Manual Motor Protector + C320WC25 Wiring Connector Link + CE12 IEC Miniature Contactor) FLA Single-Phase Three-Phase Manual IEC Non-reversing Catalog Price � � �� Adjustment hp Ratings hp Ratings Motor Contactor Number U.S. $ Range Protector 115V 230V 200V 230V 460V 575V AC Coil DC Coil 0.11 – 0.16 — — — — — — A307AN CE12BNC310_ AM317ANS3_ 0.14 – 0.20 — — — — — — A307BN CE12BNC310_ AM317BNS3_ 0.18 – 0.25 — — — — — — A307CN CE12BNC310_ AM317CNS3_ 0.22 – 0.32 — — — — — — A307DN CE12BNC310_ AM317DNS3_ 0.28 – 0.40 — — — — — — A307EN CE12BNC310_ AM317ENS3_ 0.35 – 0.50 — — — — — — A307FN CE12BNC310_ AM317FNS3_ 0.45 – 0.63 — — — — — 1/4 A307GN CE12BNC310_ AM317GNS3_ 0.55 – 0.8 — — — — 1/4 1/2 A307HN CE12BNC310_ AM317HNS3_ 0.7 – 1.0 — — — — 1/2 1/2 A307JN CE12BNC310_ AM317JNS3_ 0.9 – 1.25 — — — 1/4 3/4 3/4 A307KN CE12BNC310_ AM317KNS3_ 1.1 – 1.6 — 1/10 1/4 1/3 3/4 1 A307LN CE12BNC310_ AM317LNS3_ 1.4 – 2.0 — 1/8 1/3 1/2 1 1-1/2 A307MN CE12BNC310_ AM317MNS3_ 1.8 – 2.5 — 1/6 1/2 1/2 1-1/2 1-1/2 A307NN CE12BNC310_ AM317NNS3_ 2.2 – 3.2 1/10 1/4 3/4 3/4 1-1/2 2 A307PN CE12BNC310_ AM317PNS3_ 2.8 – 4.0 1/8 1/3 3/4 1 2 3 A307RN CE12BNC310_ AM317RNS3_ 3.5 – 5.0 1/6 1/2 1 1 3 3 A307SN CE12BNC310_ AM317SNS3_ 4.5 – 6.3 1/4 3/4 1-1/2 1-1/2 5 5 A307TN CE12CNC310_ AM317TNS3_ 5.5 – 8.0 1/3 1 2 2 5 5 A307UN CE12CNC310_ AM317UNS3_ 7.0 – 10.0 1/2 1-1/2 3 3 7-1/2 10 A307VN CE12CNC310_ AM317VNS3_ � Select motor controller by motor Full Load Amperes. Horsepower ratings are for reference only. � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-390 below. � DIN rail mounting. No mounting plate included. Table 34-390. AC and DC Coil Suffixes Notes — Coil Volts and Hertz Code Suffix ■ Each Combination Motor Controller Includes: (1) C320FMC11 Front AC Coils Mount Auxiliary Contact 1NO/1NC. 120/60 or 110/50 A 240/60 or 220/50 B ■ For information on the usage of 480/60 or 440/50 C Line Side Adapters, see Table 34- 600/60 or 550/50 D 403, Page 34-307. 208/60 E Note: For more information on Manual 277/60 H Motor Protectors and Wiring Connector 380 – 415/50 L 34-299. For 24/60, 24/50 T Links refer to Pages 34-294 – Freedom Contactors refer to Pages 34-261 – DC Coils 34-289. 120V DC A1 12V DC R1 24V DC T1 48V DC W1 Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-307 Dimensions. . . . . . . . . . . . . . . . . . . . . . Page 34-308 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-302 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers For use as CMCs in Group Installation ■ For motors with service factors less or UL 508 Type F applications. than 1.15, multiply the motor FLA by .92 to select the appropriate motor When Ordering Specify — controller. Example: For a motor ■ Select required assembled motor having FLA of 6.4A and a service controller by Catalog Number from factor of 1.0 (6.4A x .92 = 5.88A) Table 34-391 and replace underscore select Catalog Number (_) in the Catalog Number with the AM357TNS3_. 34 proper Magnetic Coil Code Suffix ■ For motors with service factor of Letter from Table 34-392. 1.15 or greater, use motor name- ■ All Non-reversing and Reversing plate Full Load Amperes to select motor controllers are selected based the appropriate motor controller. on the overload current range Example: For motor having FLA of required for a given motor. This cur- 6.4A and service factor of 1.15, rent range is determined from the select Catalog Number motor Full Load Ampere rating and AM357UNS3_. AM357 — Miniature Freedom IEC Open Reversing Motor Service Factor usually found Instructional Leaflets Combination Motor Controller on the motor nameplate. See Page 34-300 for Listing. Table 34-391. Freedom IEC Open Reversing Combination Motor Controllers (A307 Manual Motor Protector + C320WC25 Wiring Connector Link + CE52 IEC Miniature Reversing Contactor) FLA Single-Phase Three-Phase Manual IEC Reversing Catalog Price � � �� Adjustment hp Ratings hp Ratings Motor Contactor Number U.S. $ Range Protector 115V 230V 200V 230V 460V 575V AC Coil DC Coil 0.11 – 0.16 — — — — — — A307AN CE52BNC310_ AM357ANS3_ 0.14 – 0.20 — — — — — — A307BN CE52BNC310_ AM357BNS3_ 0.18 – 0.25 — — — — — — A307CN CE52BNC310_ AM357CNS3_ 0.22 – 0.32 — — — — — — A307DN CE52BNC310_ AM357DNS3_ 0.28 – 0.40 — — — — — — A307EN CE52BNC310_ AM357ENS3_ 0.35 – 0.50 — — — — — — A307FN CE52BNC310_ AM357FNS3_ 0.45 – 0.63 — — — — — 1/4 A307GN CE52BNC310_ AM357GNS3_ 0.55 – 0.8 — — — — 1/4 1/2 A307HN CE52BNC310_ AM357HNS3_ 0.7 – 1.0 — — — — 1/2 1/2 A307JN CE52BNC310_ AM357JNS3_ 0.9 – 1.25 — — — 1/4 3/4 3/4 A307KN CE52BNC310_ AM357KNS3_ 1.1 – 1.6 — 1/10 1/4 1/3 3/4 1 A307LN CE52BNC310_ AM357LNS3_ 1.4 – 2.0 — 1/8 1/3 1/2 1 1-1/2 A307MN CE52BNC310_ AM357MNS3_ 1.8 – 2.5 — 1/6 1/2 1/2 1-1/2 1-1/2 A307NN CE52BNC310_ AM357NNS3_ 2.2 – 3.2 1/10 1/4 3/4 3/4 1-1/2 2 A307PN CE52BNC310_ AM357PNS3_ 2.8 – 4.0 1/8 1/3 3/4 1 2 3 A307RN CE52BNC310_ AM357RNS3_ 3.5 – 5.0 1/6 1/2 1 1 3 3 A307SN CE52BNC310_ AM357SNS3_ 4.5 – 6.3 1/4 3/4 1-1/2 1-1/2 5 5 A307TN CE52CNC310_ AM357TNS3_ 5.5 – 8.0 1/3 1 2 2 5 5 A307UN CE52CNC310_ AM357UNS3_ 7.0 – 10.0 1/2 1-1/2 3 3 7-1/2 10 A307VN CE52CNC310_ AM357VNS3_ � Select motor controller by motor Full Load Amperes. Horsepower ratings are for reference only. � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-392 below. � DIN rail mounting. No mounting plate included. Table 34-392. AC and DC Coil Suffixes Notes — Coil Volts and Hertz Code Suffix ■ Each Combination Motor Controller Includes: (1) C320FMC11 Front AC Coils Mount Auxiliary Contact 1NO/1NC. 120/60 or 110/50 A 240/60 or 220/50 B ■ For information on the usage of 480/60 or 440/50 C Line Side Adapters, see Table 34- 600/60 or 550/50 D 403, Page 34-307. 208/60 E Note: For more information on Manual 277/60 H Motor Protectors and Wiring Connector 380 – 415/50 L 34-299. For 24/60, 24/50 T Links refer to Pages 34-294 – Freedom Contactors refer to Pages 34-261 – DC Coils 34-289. 120V DC A1 12V DC R1 24V DC T1 48V DC W1 Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-307 Dimensions . . . . . . . . . . . . . . . . . . . . . . Page 34-308 Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-303 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers For use as CMCs in Group Installation ■ For motors with service factors less or UL 508 Type F applications. than 1.15, multiply the motor FLA by .92 to select the appropriate motor When Ordering Specify — controller. Example: For a motor ■ Select required assembled motor having FLA of 6.4A and a service controller by Catalog Number from factor of 1.0 (6.4A x .92 = 5.88A) Table 34-393 and replace underscore select Catalog Number (_) in the Catalog Number with the AE317TNS3_. 34 proper Magnetic Coil Code Suffix ■ For motors with service factor of Letter from Table 34-394. 1.15 or greater, use motor name- ■ All Non-reversing and Reversing plate Full Load Amperes to select motor controllers are selected based the appropriate motor controller. on the overload current range Example: For motor having FLA of required for a given motor. This cur- 6.4A and service factor of 1.15, rent range is determined from the select Catalog Number motor Full Load Ampere rating and AE317UNS3_. AE317 Freedom IEC Open Non-reversing Motor Service Factor usually found Combination Motor Controller Instructional Leaflets on the motor nameplate. See Page 34-300 for Listing. Table 34-393. Freedom IEC Open Non-reversing Combination Motor Controllers (A307 Manual Motor Protector + C320WC45 Wiring Connector Link + CE15 IEC 45 mm Contactor) FLA Single-Phase Three-Phase Manual IEC Non-reversing Catalog Price � � �� Adjustment hp Ratings hp Ratings Motor Contactor Number U.S. $ Range Protector 115V 230V 200V 230V 460V 575V AC Coil DC Coil 0.11 – 0.16 — — — — — — A307AN CE15ANSC3_B AE317ANS3_ 0.14 – 0.20 — — — — — — A307BN CE15ANSC3_B AE317BNS3_ 0.18 – 0.25 — — — — — — A307CN CE15ANSC3_B AE317CNS3_ 0.22 – 0.32 — — — — — — A307DN CE15ANSC3_B AE317DNS3_ 0.28 – 0.40 — — — — — — A307EN CE15ANSC3_B AE317ENS3_ 0.35 – 0.50 — — — — — — A307FN CE15ANSC3_B AE317FNS3_ 0.45 – 0.63 — — — — — 1/4 A307GN CE15ANSC3_B AE317GNS3_ 0.55 – 0.8 — — — — 1/4 1/2 A307HN CE15ANSC3_B AE317HNS3_ 0.7 – 1.0 — — — — 1/2 1/2 A307JN CE15ANSC3_B AE317JNS3_ 0.9 – 1.25 — — — 1/4 3/4 3/4 A307KN CE15ANSC3_B AE317KNS3_ 1.1 – 1.6 — 1/10 1/4 1/3 3/4 1 A307LN CE15ANSC3_B AE317LNS3_ 1.4 – 2.0 — 1/8 1/3 1/2 1 1-1/2 A307MN CE15ANSC3_B AE317MNS3_ 1.8 – 2.5 — 1/6 1/2 1/2 1-1/2 1-1/2 A307NN CE15ANSC3_B AE317NNS3_ 2.2 – 3.2 1/10 1/4 3/4 3/4 1-1/2 2 A307PN CE15ANSC3_B AE317PNS3_ 2.8 – 4.0 1/8 1/3 3/4 1 2 3 A307RN CE15ANSC3_B AE317RNS3_ 3.5 – 5.0 1/6 1/2 1 1 3 3 A307SN CE15ANSC3_B AE317SNS3_ 4.5 – 6.3 1/4 3/4 1-1/2 1-1/2 5 5 A307TN CE15BNSC3_B AE317TNS3_ 5.5 – 8.0 1/3 1 2 2 5 5 A307UN CE15BNSC3_B AE317UNS3_ 7.0 – 10.0 1/2 1-1/2 3 3 7-1/2 10 A307VN CE15CNSC3_B AE317VNS3_ 9.0 – 12.5 1/2 2 3 3 7-1/2 10 A307WN CE15CNSC3_B AE317WNS3_ 11.0 – 16.0 1 3 5 5 10 15 A307XN CE15DNSC3_B AE317XNS3_ 14.0 – 20.0 1-1/2 3 5 7-1/2 15 20 A307YN CE15ENSC3_B AE317YNS3_ 17.0 – 22.0 2 3 7-1/2 7-1/2 15 20 A307ZN CE15FNSC3_B AE317ZNS3_ � Select motor controller by motor Full Load Amperes. Horsepower ratings are for reference only. � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-394 below. � DIN rail mounting. No mounting plate included. Note: For more information on Manual Table 34-394. AC and DC Coil Suffixes Notes — Motor Protectors and Wiring Connector Coil Volts and Hertz Code Suffix ■ Each Combination Motor Controller 34-299. For Links refer to Pages 34-294 – Includes: (1) C320FMC11 Front AC Coils Freedom Contactors refer to Pages 34-261 – Mount Auxiliary Contact 1NO/1NC. 34-289. 120/60 or 110/50 A 240/60 or 220/50 B ❑ The auxiliary contact is desig- 480/60 or 440/50 C nated by the S in the following 600/60 or 550/50 D Catalog Number example: 208/60 E AE317ANS3A. 277/60 H 380 – 415/50 L ■ The CE15***C* signifies a black 24/60, 24/50 T base, A1 & A2 coil terminals at the DC Coils bottom and black printing on the label. 120V DC A1 12V DC R1 ■ For information on the usage of 24V DC T1 Line Side Adapters, see Table 34- Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-307 48V DC W1 Dimensions. . . . . . . . . . . . . . . . . . . . . . Page 34-308 403, Page 34-307. Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-304 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers For use as CMCs in Group Installation ■ For motors with service factors less or UL 508 Type F applications. than 1.15, multiply the motor FLA by .92 to select the appropriate motor When Ordering Specify — controller. Example: For a motor ■ Select required assembled motor having FLA of 6.4A and a service controller by Catalog Number from factor of 1.0 (6.4A x .92 = 5.88A) Table 34-395 and replace underscore select Catalog Number (_) in the Catalog Number with the AE357TNS3_. 34 proper Magnetic Coil Code Suffix ■ For motors with service factor of Letter from Table 34-396. 1.15 or greater, use motor name- ■ All Non-reversing and Reversing plate Full Load Amperes to select motor controllers are selected based the appropriate motor controller. on the overload current range Example: For motor having FLA of required for a given motor. This cur- 6.4A and service factor of 1.15, rent range is determined from the select Catalog Number motor Full Load Ampere rating and AE357UNS3_. AE357 — Freedom IEC Open Reversing Motor Service Factor usually found Combination Motor Controller Instructional Leaflets on the motor nameplate. See Page 34-300 for Listing. Table 34-395. Freedom IEC Open Reversing Combination Motor Controllers (A307 Manual Motor Protector + CE55 IEC 45 mm Reversing Contactor) FLA Single-Phase Three-Phase Manual IEC Reversing Catalog Price � � ��� Adjustment hp Ratings hp Ratings Motor Contactor Number U.S. $ Range Protector 115V 230V 200V 230V 460V 575V AC Coil DC Coil 0.11 – 0.16 — — — — — — A307AN CE55ANSC3_B AE357ANS3_ 0.14 – 0.20 — — — — — — A307BN CE55ANSC3_B AE357BNS3_ 0.18 – 0.25 — — — — — — A307CN CE55ANSC3_B AE357CNS3_ 0.22 – 0.32 — — — — — — A307DN CE55ANSC3_B AE357DNS3_ 0.28 – 0.40 — — — — — — A307EN CE55ANSC3_B AE357ENS3_ 0.35 – 0.50 — — — — — — A307FN CE55ANSC3_B AE357FNS3_ 0.45 – 0.63 — — — — — 1/4 A307GN CE55ANSC3_B AE357GNS3_ 0.55 – 0.8 — — — — 1/4 1/2 A307HN CE55ANSC3_B AE357HNS3_ 0.7 – 1.0 — — — — 1/2 1/2 A307JN CE55ANSC3_B AE357JNS3_ 0.9 – 1.25 — — — 1/4 3/4 3/4 A307KN CE55ANSC3_B AE357KNS3_ 1.1 – 1.6 — 1/10 1/4 1/3 3/4 1 A307LN CE55ANSC3_B AE357LNS3_ 1.4 – 2.0 — 1/8 1/3 1/2 1 1-1/2 A307MN CE55ANSC3_B AE357MNS3_ 1.8 – 2.5 — 1/6 1/2 1/2 1-1/2 1-1/2 A307NN CE55ANSC3_B AE357NNS3_ 2.2 – 3.2 1/10 1/4 3/4 3/4 1-1/2 2 A307PN CE55ANSC3_B AE357PNS3_ 2.8 – 4.0 1/8 1/3 3/4 1 2 3 A307RN CE55ANSC3_B AE357RNS3_ 3.5 – 5.0 1/6 1/2 1 1 3 3 A307SN CE55ANSC3_B AE357SNS3_ 4.5 – 6.3 1/4 3/4 1-1/2 1-1/2 5 5 A307TN CE55BNSC3_B AE357TNS3_ 5.5 – 8.0 1/3 1 2 2 5 5 A307UN CE55BNSC3_B AE357UNS3_ 7.0 – 10.0 1/2 1-1/2 3 3 7-1/2 10 A307VN CE55CNSC3_B AE357VNS3_ 9.0 – 12.5 1/2 2 3 3 7-1/2 10 A307WN CE55CNSC3_B AE357WNS3_ 11.0 – 16.0 1 3 5 5 10 15 A307XN CE55DNSC3_B AE357XNS3_ 14.0 – 20.0 1-1/2 3 5 7-1/2 15 20 A307YN CE55ENSC3_B AE357YNS3_ 17.0 – 22.0 2 3 7-1/2 7-1/2 15 20 A307ZN CE55FNSC3_B AE357ZNS3_ � Select motor controller by motor Full Load Amperes. Horsepower ratings are for reference only. � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-396 below. � Mounting plate included. � Add -DIN Modification Code for DIN Rail mounting of contactors with MMP and Wiring Connector Link. Note: For more information on Manual Table 34-396. AC and DC Coil Suffixes Notes — Motor Protectors and Wiring Connector Coil Volts and Hertz Code Suffix ■ Each Combination Motor Controller 34-299. For Links refer to Pages 34-294 – Includes: (1) C320FMC11 Front AC Coils Freedom Contactors refer to Pages 34-261 – Mount Auxiliary Contact 1NO/1NC. 34-289. 120/60 or 110/50 A 240/60 or 220/50 B ❑ The auxiliary contact is desig- 480/60 or 440/50 C nated by the S in the following 600/60 or 550/50 D Catalog Number example: 208/60 E AE357ANS3A. 277/60 H 380 – 415/50 L ■ The CE55***C* signifies a black 24/60, 24/50 T base, A1 & A2 coil terminals at the DC Coils bottom and black printing on the label. 120V DC A1 12V DC R1 ■ For information on the usage of 24V DC T1 Line Side Adapters, see Table 34- Accessories . . . . . . . . . . . . . . . . . . . . . Page 34-307 48V DC W1 Dimensions . . . . . . . . . . . . . . . . . . . . . . Page 34-308 403, Page 34-307. Discount Symbol . . . . . . . . . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-305 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers For use as CMCs in Group Installation ■ For motors with service factors less or UL 508 Type F applications. than 1.15, multiply the motor FLA by .92 to select the appropriate motor When Ordering Specify — controller. Example: For a motor ■ Select required assembled motor having FLA of 45A and a service fac- controller by Catalog Number from tor of 1.0 (45A x .92 = 41.40A) select Table 34-397 or Table 34-398 and Catalog Number AE318SNS3_. replace underscore (_) in the Cata- ■ For motors with service factor of 34 log Number with the proper Mag- 1.15 or greater, use motor name- netic Coil Code Suffix Letter from plate Full Load Amperes to select Table 34-399. the appropriate motor controller. ■ All Non-reversing and Reversing Example: For motor having FLA of motor controllers are selected based 45A and service factor of 1.15, select on the overload current range Catalog Number AE318TNS3_. AE318 & AE358 — Freedom IEC Open required for a given motor. This cur- Non-reversing and IEC Open Reversing Instructional Leaflets Combination Motor Controllers rent range is determined from the motor Full Load Ampere rating and See Page 34-300 for Listing. Motor Service Factor usually found on the motor nameplate. Table 34-397. Freedom IEC Open Non-reversing Combination Motor Controllers (A308 Manual Motor Protector + C320WC65 Wiring Connector Link + CE15 IEC 65 mm Contactor) FLA Single-Phase Three-Phase Manual IEC Non-reversing Catalog Price � � �� Adjustment hp Ratings hp Ratings Motor Contactor Number U.S. $ Range Protector 115V 230V 200V 230V 460V 575V AC Coil DC Coil 11 – 16 1 3 5 5 10 15 A308LN CE15GNSC3_B AE318LNS3_ 14 – 20 1-1/2 3 5 7-1/2 15 20 A308MN CE15GNSC3_B AE318MNS3_ 18 – 25 2 5 7-1/2 10 20 25 A308NN CE15GNSC3_B AE318NNS3_ 22 – 32 2 5 10 10 25 30 A308PN CE15HNSC3_B AE318PNS3_ 28 – 40 3 7-1/2 10 15 30 40 A308RN CE15JNSC3_B AE318RNS3_ 36 – 45 3 7-1/2 15 15 30 40 A308SN CE15JNSC3_B AE318SNS3_ 40 – 50 3 10 15 15 40 50 A308TN CE15JNSC3_B AE318TNS3_ � Select motor controller by motor Full Load Amperes. Horsepower ratings are for reference only. � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-399 below. � Mounting plate included. Table 34-398. Freedom IEC Open Reversing Combination Motor Controllers (A308 Manual Motor Protector + CE55 IEC 65 mm Reversing Contactor) FLA Single-Phase Three-Phase Manual IEC Reversing Catalog Price � � �� Adjustment hp Ratings hp Ratings Motor Contactor Number U.S. $ Range Protector 115V 230V 200V 230V 460V 575V AC Coil DC Coil 11 – 16 1 3 5 5 10 15 A308LN CE55GNSC3_B AE358LNS3_ 14 – 20 1-1/2 3 5 7-1/2 15 20 A308MN CE55GNSC3_B AE358MNS3_ 18 – 25 2 5 7-1/2 10 20 25 A308NN CE55GNSC3_B AE358NNS3_ 22 – 32 2 5 10 10 25 30 A308PN CE55HNSC3_B AE358PNS3_ 28 – 40 3 7-1/2 10 15 30 40 A308RN CE55JNSC3_B AE358RNS3_ 36 – 45 3 7-1/2 15 15 30 40 A308SN CE55JNSC3_B AE358SNS3_ 40 – 50 3 10 15 15 40 50 A308TN CE55JNSC3_B AE358TNS3_ � Select motor controller by motor Full Load Amperes. Horsepower ratings are for reference only. � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-399 below. � Mounting plate included. Table 34-399. AC and DC Coil Suffixes Notes — ■ Modified 65 mm CE15/55 Contactors only with coil terminals at bottom Coil Volts and Hertz Code Suffix ■ Each Combination Motor Controller will not allow the use of top Includes: (1) C320FMC11 Front AC Coils mounted accessories. Mount Auxiliary Contact 1NO/1NC. 120/60 or 110/50 A 240/60 or 220/50 B ❑ The auxiliary contact is desig- Note: For more information on Manual 480/60 or 440/50 C nated by the S in the following Motor Protectors and Wiring Connector 600/60 or 550/50 D 34-299. For Links refer to Pages 34-294 – Catalog Number example: Freedom Contactors refer to Pages 34-261 – 208/60 E AE318RNS3A or AE358RNS3A. 277/60 H 34-289. 380 – 415/50 L ■ The CE15/55***C* signifies a black 24/60, 24/50 T base, A1 & A2 coil terminals at the DC Coils bottom and black printing on the label. 120V DC A1 12V DC R1 24V DC T1 Accessories . . . . . . . . . . . . . . Page 34-307 48V DC W1 Dimensions. . . . . . . . . . . . . . . Pages 34-309, 34-310 Discount Symbol . . . . . . . . . . 1CD7 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-306 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers For use as CMCs in Group Installation or UL 508 Type F applications. ■ For motors with service factors less When Ordering Specify — than 1.15, multiply the motor FLA by .92 to select the appropriate motor ■ Select required assembled motor controller. Example: For a motor controller by Catalog Number from having FLA of 45A and a service fac- Table 34-400 or Table 34-401 and tor of 1.0 (45A x .92 = 41.40A) select replace underscore (_) in the Cata- Catalog Number AE319SNS3_. 34 log Number with the proper Mag- netic Coil Code Suffix Letter from ■ For motors with service factor of 1.15 or greater, use motor name- Table 34-402. plate Full Load Amperes to select ■ All Non-reversing and Reversing the appropriate motor controller. motor controllers are selected based Example: For motor having FLA of on the overload current range 45A and service factor of 1.15, select required for a given motor. This cur- Catalog Number AE319TNS3_. rent range is determined from the motor Full Load Ampere rating and AE319 & AE359 — Freedom IEC Open Instructional Leaflets Non-reversing and IEC Open Reversing Motor Service Factor usually found See Page 34-300 for Listing. Combination Motor Controllers on the motor nameplate. Table 34-400. Freedom IEC Open Non-reversing Combination Motor Controllers (C320LSA2, A309 Manual Motor Protector + CE15 IEC 90 mm Contactor) FLA Single-Phase Three-Phase Manual IEC Non-reversing Catalog Price � � �� Adjustment hp Ratings hp Ratings Motor Contactor Number U.S. $ Range Protector 115V 230V 200V 230V 460V 575V AC Coil DC Coil 28 – 40 3 7-1/2 15 15 30 40 A309RN CE15LNC3 AE319RNS3_ 36 – 50 3 10 15 20 40 50 A309SN CE15LNC3 AE319SNS3_ 45 – 63 5 15 20 25 50 60 A309TN CE15LNC3 AE319TNS3_ 57 – 75 7-1/2 15 25 25 60 75 A309UN CE15LNC3 AE319UNS3_ 70 – 90 10 20 30 30 75 100 A309VN CE15MNC3 AE319VNS3_ 80 – 100 10 20 30 30 75 100 A309WN CE15NNC3 AE319WNS3_ � Select motor controller by motor Full Load Amperes. Horsepower ratings are for reference only. � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-402 below. � Mounting plate included. Table 34-401. Freedom IEC Open Reversing Combination Motor Controllers (C320LSA2, A309 Manual Motor Protector + CE55 IEC 90 mm Reversing Contactor) FLA Single-Phase Three-Phase Manual IEC Reversing Catalog Price � � �� Adjustment hp Ratings hp Ratings Motor Contactor Number U.S. $ Range Protector 115V 230V 200V 230V 460V 575V AC Coil DC Coil 28 – 40 3 7-1/2 15 15 30 40 A309RN CE55LNC3 AE359RNS3_ 36 – 50 3 10 15 20 40 50 A309SN CE55LNC3 AE359SNS3_ 45 – 63 5 15 20 25 50 60 A309TN CE55LNC3 AE359TNS3_ 57 – 75 7-1/2 15 25 25 60 75 A309UN CE55LNC3 AE359UNS3_ 70 – 90 10 20 30 30 75 100 A309VN CE55MNC3 AE359VNS3_ 80 – 100 10 20 30 30 75 100 A309WN CE55NNC3 AE359WNS3_ � Select motor controller by motor Full Load Amperes. Horsepower ratings are for reference only. � Underscore (_) indicates Magnetic Coil Suffix required. See Table 34-402 below. � Mounting plate included. Note: For more information on Manual Table 34-402. AC and DC Coil Suffixes Notes — Motor Protectors and Wiring Connector Coil Volts and Hertz Code Suffix ■ Each Combination Motor Controller Links refer to Pages 34-294 – 34-299. For Includes: (1) C320FMC11 Front AC Coils Freedom Contactors refer to Pages 34-261 – Mount Auxiliary Contact 1NO/1NC 34-289. 120/60 or 110/50 A and (1) C320LSA2 Line Side Adapter. 240/60 or 220/50 B 480/60 or 440/50 C ❑ The auxiliary contact is desig- 600/60 or 550/50 D nated by the S in the following 208/60 E Catalog Number example: 277/60 H AE319SNS3A or AE359SNS3A. 380 – 415/50 L 24/60, 24/50 T ■ The CE15/55***C* signifies a black DC Coils base, A1 & A2 coil terminals at the bottom and black printing on the 120V DC A1 12V DC R1 label. 24V DC T1 Accessories . . . . . . . . . . . . . Page 34-307 48V DC W1 Dimensions . . . . . . . . . . . . . . Pages 34-309, 34-310 Discount Symbol . . . . . . . . . 1CD7 For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-307 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers Protection in Different Controller Accessories Types Table 34-403. Line Side Adapters (C320LSA1 and C320LSA2) — A UL 508 Type E Self-protected Manual When to Use Them for U.S. Applications Combination Starter/Motor Controller consists of a single device having inte- gral short circuit protection, a main set Freedom Combination Motor Controller (CMC) of contacts, motor overload protec- 34 tion, and may also include a UL Listed Line Side Adapter (see Table 34-403). This type of controller is a legitimate IEC Combination IEC Combination short-circuit circuit protective device Motor Controllers Motor Controllers and disconnect means for the down- Types AM/AE317/357 & AE319/359 Types AE318/358 stream motor. It does require an upstream feeder short circuit protec- tive device, but does not require a ded- icated branch circuit protection or a Line Side Adapter Line Side Adapter Line Side Adapter disconnect means. A UL 508 Type E Not Required Required Not required for any application rating means that the unit clears a fault and does not experience any welding of the power poles. A UL 508 Type E self-protected manual motor controller will remain fully functional should a � � Group Installation MMP /Contactor MMP Only short circuit within its ratings occur. Using the in-panel UL 508 Type F Combination UL 508 Type E Self-protected E.g. A307, A308 and A309. � Main SCPD Motor Controller — Only Manual Combination Starter — � � Upstream Feeder SCPD Only Upstream Feeder SCPD A UL 508 Type F Combination Motor required; no dedicated required; no dedicated in-panel Controller consists of a UL Listed � � � in-panel Main SCPD for Main SCPD for MMP Type E Self-protected Manual Combi- � MMP /Contactor nation Starter/Motor Controller, a UL Listed Contactor, and possibly a UL � Listed Line Side Adapter (see Table 34- SCPD = Short Circuit Protective Device (Circuit Breaker, Fuses). � 403). While the UL 508 Type E self- MMP = Manual Motor Protector. protected manual motor controller Reference: Technical Paper AP03402001E. of this combination motor controller Note: Line Side Adapters are not required for non-U.S. applications. Most countries outside device is a legitimate short circuit of the U.S. classify the MMP as a thermal magnetic circuit breaker. protective device and disconnect Table 34-404. Accessories means for the downstream motor, Description Catalog Price the contactor is not “self-protected.” Number U.S. $ E.g. AM317 – AE319 and AM357 – AE359. Line Side Adapter for A307 MMPs C320LSA1 (Required for use with A307 MMPs In addition, as a complete assembly or only when used as Self-Protected Manual Combination Starters. Not with modular components, the device required for Group Installation.) may have Type 2 Coordination certifi- cation. Type 2 Coordination means the � Line Side Adapter for A309 MMPs C320LSA2 Starter or Controller must exhibit little (Required for use with A309 MMPs or no damage following a major short only when used as Self-Protected circuit fault and should be able to be Manual Combination Starters. Not returned to proper service without required for Group Installation.). replacing any parts. E.g. All Freedom CMCs and MMPs. Wiring Connector Link C320WC25 (Electrical and mechanical intercon- nection between A307 MMP + CE12 Freedom Miniature FVNR/FVR Contactor) Wiring Connector Link C320WC45 (Electrical and mechanical intercon- nection between A307 MMP + CE15 Freedom 45 mm IEC FVNR Contactor — Sizes A – F) Wiring Connector Link C320WC65 (Electrical and mechanical intercon- nection between A308 MMP + CE15 Freedom 65 mm IEC FVNR Contactor — Sizes G – K) � A308 MMP does not require a Line Side Adapter. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1 CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-308 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers Dimensions 1.00 (25.4) 34 A307 MMP 6.33 (160.8) 6.93 (176.0) Wiring Connector Link 4.39 3.27 (111.4) (83.0) CE12 Mini Contactor 3.76 .35 (95.4) 1.53 (8.9) (38.8) 1.24 (31.4) 1.88 (47.8) Figure 34-169. Non-reversing Combination Motor Controller AM317 (A307 MMP + C320WC25 WCL + CE12 Mini Contactor) — Approximate Dimensions in Inches (mm) .59 1.00 (15.0) (25.4) 7.16 (182.0) 8.22 (208.8) 1.77 1.33 3.76 (45.0) (33.7) (95.4) View Shown from Bottom Drawing Showing the 4-Pole Contactor, 3-Pole Has the Same Overall Dimensions Figure 34-170. Non-reversing Combination Motor Controller AE317 (A307 MMP + C320WC45 WCL + CE15 45 mm Contactor) — Approximate Dimensions in Inches (mm) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-309 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers .31 (7.9) .22 (5.5) Radius 34 9.22 11.0 (234.2) (279.0) 11.5 (292.1) .31 (7.9) 2.0 6.05 (153.6) (50.8) .22 .60 (15.2) 2.6 (5.5) (67.0) Dia. Figure 34-171. Non-reversing Combination Motor Controller AE318 (A308 MMP + C320WC65 WCL + CE15 65 mm Contactor) — Approximate Dimensions in Inches (mm) 2.68 7.13 (68.0) (181.1) 15.84 1.57 (402.4) (39.9) 16.54 (420.0) 2.91 5.75 (74.0) (146.1) 3.54 (89.8) Figure 34-172. Non-reversing Combination Motor Controller AE319 (LSA, A309 MMP + CE15 90 mm Contactor) — Approximate Dimensions in Inches (mm) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-310 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers 1.75 (44.6) 34 6.93 (176.0) 6.33 5.99 Reversing (160.8) (152.2) Strap 3.26 (82.9) 1.97 (50.0) Load 1.77 Side 3.76 (45.0) Strap (95.4) 3.80 (96.5) Figure 34-173. Reversing Combination Motor Controller AM357 (A307 MMP + C320WC25 WCL + CE52 Mini Contactor) — Approximate Dimensions in Inches (mm) 3.96 (100.6) 4.25 (108.0) .07 (1.8) .59 (15.0) 1.53 (38.8) 9.06 9.54 (230.1) (242.3) 1.55 (39.3) .73 (18.6) 1.75 (44.5) 3.47 (88.1) 3.50 (88.9) 4.13 (104.8) 5.19 (131.7) Figure 34-174. Reversing Combination Motor Controller AE357 (A307 MMP + CE55 45 mm Contactor) — Approximate Dimensions in Inches (mm) For more information visit: www.eaton.com CA08102001E IEC Contactors & Starters 34-311 Freedom MMPs & Manual and Combination Motor Controllers March 2009 Types AM/AE317/357, AE318/358, AE319/359 Freedom IEC Combination Motor Controllers 5.77 (146.5) 6.05 (153.6) .22 (5.5) Dia. 34 11.00 11.50 (279.4) (292.1) 4.50 (114.3) 6.60 (167.6) Figure 34-175. Reversing Combination Motor Controller AE358 (A308 MMP + CE55 65 mm Contactor) — Approximate Dimensions in Inches (mm) 7.62 (193.5) 7.16 (181.9) 6.77 (172.0) 17.28 17.93 (438.9) (455.4) 7.00 (177.8) 8.69 (220.7) Figure 34-176. Reversing Combination Motor Controller AE359 (LSA, A309 MMP + CE55 90 mm Contactor) — Approximate Dimensions in Inches (mm) CA08102001E For more information visit: www.eaton.com IEC Contactors & Starters 34-312 March 2009 This page intentionally left blank. 34 For more information visit: www.eaton.com CA08102001E

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the XTOB057DC1?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Cutler-Hammer 10-6530-4 Overload Relay Used on Size 4 Freedom Starter

Cutler Hammer D100CR40A - Relay