Industrial Trading chervon right Manufacturers chervon right C chervon right CARRIER ACCESS chervon right 005-0064
About product Datasheet FAQ

CARRIER ACCESS 005-0064

Description

12 ft. serial console cable with a DB-9 female and DB-9 male

Part Number

005-0064

Price

Request Quote

Manufacturer

CARRIER ACCESS

Lead Time

Request Quote

Category

None

Datasheet

pdf file

930-0370.pdf

102 KiB

Extracted Text

Axxius 800 Product Guide Axxius 800 Release 2.0 Access integration platform with redundancy features that fulfill multiport CSU/DSU, Integrated Access Device, Terminal Server Router, Transcoder, and 3/1/0 Digital Cross-connect applications. Supports DS3 add-drop functions, up to 36 T1s, 16 V.35 ports, or 32 Terminal Server/Ethernet ports. Supports Adit 600 FXO, ISDN-BRI and OCU-DP Cards. A single POTS voice card is also available for provisioning an order-wire voice line. integrated SNMP and GUI management software. The most versatile small 3/1/0 Integration Access Platform available for service providers Item Part Number Description Configured T1 Systems (24VDC) This Base System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (1) 24VDC Axxius 800 DS1 Non-Redundant Base System 24VDC 11-0-000000000-50 Power Supply card, 19- and 23-inch Rack Mounts, and blank card faceplates This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (1) Axxius 800 DS1 Non-Redundant System 24VDC with 8 11-0-QT0000000-50 24VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, and (1) Quad T1 Ports and 4 TSR Ports Terminal Server Router card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (1) Axxius 800 DS1 Non-Redundant System 24VDC with 8 11-0-QTV000000-50 24VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, (1) Quad Terminal T1 Ports, 4 TSR Ports and 2 V.35 Ports Server Router card, and (1) Dual V.35 card This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (1) Axxius 800 DS1 Non-Redundant System 24VDC with 8 11-0-QTVZ00000-50 24VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, (1) Quad Terminal T1 Ports, 4 TSR Ports, 2 V.35 Ports, and 1 POTS Port Server Router card, (1) Dual V.35 card, and (1) Single Channel POTS card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (1) Axxius 800 DS1 Non-Redundant System 24VDC with 4 11-0-W00000000-50 24VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, and (1) Single Channel POTS with T1 Ports and 1 POTS w/Modem Modem card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (1) Axxius 800 Redundant DS1 Controller System 24VDC 12-0-TW0000000-50 24VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad Terminal Server Router card, with 4 T1 Ports, 4 TSR Ports, 1 POTS w/Modem and (1) Single Channel POTS with Modem card. Axxius 800 DS1 System with Redundant 24VDC and 8 This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (2) 21-0-Q00000000-50 T1 Ports 24VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (1) Quad T1 card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (2) Axxius 800 DS1 System with Redundant 24VDC, 16 T1 21-0-QQQ0000Z0-50 24VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (3) Quad T1 card, and (1) Single Ports and 1 POTS Port Channel POTS card. This Base System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards (2) 24VDC Axxius 800 DS1 Redundant Base System 24VDC 22-0-000000000-50 Power Supply cards, 19- and 23-inch Rack Mounts, and blank card faceplates Axxius 800 DS1 Redundant System 24VDC with 12 T1 This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards (2) Ports, 4 TSR Ports, 2 V.35 Ports and POTS with 22-0-QQTVW0000-50 24VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (2) Quad T1 cards, (1) Quad Terminal Modem Server Router card, (1) Dual V.35 card, and (1) Single Channel POTS with Modem card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards (2) Axxius 800 DS1 Redundant System 24VDC with 12 T1 22-0-QQTZV0000-50 24VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (2) Quad T1 cards, (1) Quad Terminal Ports, 4 TSR Ports, 1 POTS Port and, 2 V.35 Ports Server Router card, (1) Single Channel POTS card, and (1) Dual V.35 card. 11-006 Form #CF-118, Rev. C Page 1 Updated 5/12/04 Item Part Number Description Configured T1 Systems (48VDC) This Base System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (1) 48VDC Axxius 800 DS1 Non-Redundant Base System 48VDC 31-0-000000000-50 Power Supply card, 19- and 23-inch Rack Mounts, and blank card faceplates This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (1) Axxius 800 DS1 Non-Redundant System 48VDC with 8 31-0-QT0000000-50 48VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, and (1) Quad T1 Ports and 4 TSR Ports Terminal Server Router card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (1) Axxius 800 DS1 Non-Redundant System 48VDC with 8 31-0-QTV000000-50 48VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, (1) Quad Terminal T1 Ports, 4 TSR Ports, and 2 V.35 Ports Server Router card, and (1) Dual V.35 card This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (1) Axxius 800 DS1 Non-Redundant System 48VDC with 8 31-0-QTVZ00000-50 48VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, (1) Quad Terminal T1 Ports, 4 TSR Ports, 2 V.35 Ports, and 1 POTS Port Server Router card, (1) Dual V.35 card, and (1) Single Channel POTS card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller card, (1) Axxius 800 DS1 Non-Redundant System 48VDC with 4 31-0-T00000000-50 48VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, and (1) Quad Terminal Server Router T1 Ports & 4 TSR Ports card. Axxius 800 Redundant DS1 Controller System 48VDC, This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (1) 8 T1 Ports, 4 TSR Ports, POTS w/Modem, POTS Port, 32-0-QTWZV0000-50 48VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, (1) Quad Terminal and 2 V.35 Ports Server Router card, (1) Single Channel POTS with Modem card, (1) Single Channel POTS card, and (1) Dual V.35 card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (1) Axxius 800 Redundant DS1 Controller System 48VDC, 32-0-TW0000000-50 48VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad Terminal Server Router card, 4 T1 Ports, 4 TSR Ports, and POTS w/Modem and (1) Single Channel POTS with Modem card. Axxius 800 DS1 System with Redundant 48VDC and 8 This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Quad DS1 Controller cards, (2) 41-0-Q00000000-50 T1 Ports 48VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, and (1) Quad T1 card. This Base System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (2) 48VDC Axxius 800 DS1 Redundant Base System 48VDC 42-0-000000000-50 Power Supply cards, 19- and 23-inch Rack Mounts, and blank card faceplates Axxius 800 DS1 Redundant System 48VDC with 36 T1 This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (2) 42-0-QQQQQQQQ0-50 Ports 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (8) Quad T1 cards. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (2) Axxius 800 DS1 Redundant System 48VDC with 36 T1 42-0-QQQQQQQQ1-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (8) Quad T1 cards, and (1) Low Speed Ports and Low Speed Protection Protection card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (2) Axxius 800 DS1 Redundant System 48VDC with 12 T1 42-0-QQT000000-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (2) Quad T1 cards, and (1) Quad Ports and 4 TSR Ports Terminal Server Router card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (2) Axxius 800 DS1 Redundant System 48VDC with 8 T1 42-0-QT0000000-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, and (1) Quad Ports and 4 TSR Ports Terminal Server Router card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (2) Axxius 800 DS1 Redundant System 48VDC with 8 T1 42-0-QTWV00000-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, (1) Quad Terminal Ports, 4 TSR Ports, POTS w/Modem and 2 V.35 Ports Server Router card, (1) Single Channel POTS with Modem card, and (1) Dual V.35 card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (2) Axxius 800 DS1 Redundant System 48VDC with 8 T1 42-0-QTZV00000-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, (1) Quad Terminal Ports, 4 TSR Ports, POTS Port and 2 V.35 Ports Server Router card, (1) Single Channel POTS card, and (1) Dual V.35 card. Axxius 800 DS1 Redundant 48VDC System with 4 OCU This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (2) 42-0-P00000000-50 DP Ports NI48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (1) Quad OCU-DP card. Axxius 800 DS1 Redundant System 48VDC with 8 OCU This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (2) 42-0-PP0000000-50 DP Ports NI48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (2) Quad OCU-DP cards. 11-006 Form #CF-118, Rev. C Page 2 Updated 5/12/04 Item Part Number Description This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Quad DS1 Controller cards, (2) Axxius 800 DS1 Redundant System 48VDC with 8 T1 42-0-QPP0000000-50 NI48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, and (2) Quad Ports and 8 OCU-DP Ports OCU-DP cards. Configured DS3 Systems (24VDC) This Base System includes: (1) Enclosure with Control Panel Interface card, (1) Dual DS3 Controller card, (1) 24VDC Axxius 800 DS3 Non-Redundant Base System 24VDC 13-0-000000000-50 Power Supply card, 19- and 23-inch Rack Mounts, and blank card faceplates This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Dual DS3 Controller card, (1) Axxius 800 DS3 Non-Redundant System 24VDC with 8 13-0-QQTZ00000-50 24VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (2) Quad T1 cards, (1) Quad Terminal T1 Ports, 4 TSR Ports, and 1 POTS Port Server Router card, and (1) Single Channel POTS card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Dual DS3 Controller card, (1) Axxius 800 DS3 Non-Redundant System 24VDC with 8 13-0-QQTZV0000-50 24VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (2) Quad T1 cards, (1) Quad Terminal T1 Ports, 4 TSR Ports, 2 V.35 Ports, and 1 POTS Port Server Router card, (1) Dual V.35 card, and (1) Single Channel POTS card. This Base System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) 24VDC Axxius 800 DS3 Redundant Base System 24VDC 24-0-000000000-50 Power Supply cards, 19- and 23-inch Rack Mounts, and blank card faceplates This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) Axxius 800 DS3 Redundant System 24VDC with 4 T1 24-0-Q000000Z0-50 24VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, and (1) Single Ports and POTS Port Channel POTS card. Axxius 800 DS3 Redundant System 24VDC with 28 T1 This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) 24-0-QQQQQQQ00-50 Ports 24VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (7) Quad T1 cards. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) Axxius 800 DS3 Redundant System 24VDC with 8 T1 24-0-QQT000000-50 24VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (2) Quad T1 cards, and (1) Quad Ports, and 4 TSR Ports Terminal Server Router card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) Axxius 800 DS3 Redundant System 24VDC with 8 T1 24-0-QQTZV0000-50 24VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (2) Quad T1 cards, (1) Quad Terminal Ports, 4 TSR Ports, 1 POTS Port, and 2 V.35 Ports Server Router card, (1) Single Channel POTS card, and (1) Dual V.35 card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) Axxius 800 DS3 Redundant System 24VDC with 12 T1 24-0-QQQV000Z0-50 24VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (3) Quad T1 cards, (1) Dual V.35 card, Ports, 2 V.35 Ports, and 1 POTS Port and (1) Single Channel POTS card. Configured DS3 Systems (48VDC) This Base System includes: (1) Enclosure with Control Panel Interface card, (1) Dual DS3 Controller card, (1) 48VDC Axxius 800 DS3 Non-Redundant Base System 48VDC 33-0-000000000-50 Power Supply card, 19- and 23-inch Rack Mounts, and blank card faceplates Axxius 800 Redundant DS3 Controller System 48VDC This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (1) with 4 T1 Ports, 4 TSR Ports, POTS w/Modem, 1 34-0-QTWZV0000-50 48VDC Power Supply card, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, (1) Quad Terminal POTS, and 2 V.35 Ports Server Router card, (1) Single Channel POTS with Modem card, (1) Single Channel POTS card, and (1) Dual V.35 card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (1) Dual DS3 Controller card, (2) Axxius 800 Non-Redundant DS3, Redundant 48VDC 43-0-QQQQQQQT0-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (7) Quad T1 cards, and (1) Quad System with 28 T1 Ports and 4 TSR Ports Terminal Server Router card. This Base System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) 48VDC Axxius 800 DS3 Redundant Base System 48VDC 44-0-000000000-50 Power Supply cards, 19- and 23-inch Rack Mounts, and blank card faceplates Axxius 800 DS3 Redundant System 48VDC with 4 T1 This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) 44-0-Q00000000-50 Ports 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (1) Quad T1 card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) Axxius 800 DS3 Redundant System 48VDC with 4 T1 44-0-Q000000Z0-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, and (1) Single Ports and POTS Channel POTS card. Axxius 800 DS3 Redundant System 48VDC with 8 T1 This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) 44-0-QQ0000000-50 Ports 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (2) Quad T1 cards. 11-006 Form #CF-118, Rev. C Page 3 Updated 5/12/04 Item Part Number Description Axxius 800 DS3 Redundant System 48VDC with 16 T1 This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) 44-0-QQQQ00000-50 Ports 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (4) Quad T1 cards. Axxius 800 DS3 Redundant System 48VDC with 28 T1 This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) 44-0-QQQQQQQ00-50 Ports 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (7) Quad T1 cards. Axxius 800 DS3 Redundant System 48VDC with 32 T1 This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) 44-0-QQQQQQQQ0-50 Ports 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (8) Quad T1 cards. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) Axxius 800 DS3 Redundant System 48VDC with 32 T1 44-0-QQQQQQQQ1-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (8) Quad T1 cards, and (1) Low Speed Ports and Low Speed Protection card Protection card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) Axxius 800 DS3 Redundant System 48VDC with 28 T1 44-0-QQQQQQQT0-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (7) Quad T1 cards, and (1) Quad Ports and 4 TSR Ports Terminal Server Router card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) Axxius 800 DS3 Redundant System 48VDC with 24 T1 44-0-QQQQQQTT0-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (6) Quad T1 cards, and (2) Quad Ports and 8 TSR Ports Terminal Server Router cards. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) Axxius 800 DS3 Redundant System 48VDC with 24 T1 44-0-QQQQQQTT1-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (6) Quad T1 cards, (2) Quad Terminal Ports, 8 TSR Ports and Low Speed Protection card Server Router cards, and (1) Low Speed Protection card. This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) Axxius 800 DS3 Redundant System 48VDC with 4 T1 44-0-QTV000000-50 48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, (1) Quad T1 card, (1) Quad Terminal Ports, 4 TSR ports, and 2 V.35 Ports Server Router card, and (1) Dual V.35 card. Axxius 800 DS3 Redundant System 48VDC with 28 This Configured System includes: (1) Enclosure with Control Panel Interface card, (2) Dual DS3 Controller cards, (2) 44-0-PPPPPPP00-50 OCU-DP ports NI48VDC Power Supply cards, 19- and 23-inch Rack Mounts, blank card faceplates, and (7) Quad OCU-DP cards. Components Axxius 800 Enclosure with Front Control Panel Interface 930-0370 Hardened Enclosure with backplane, front control panel interface card installed and blank card faceplates. Card Axxius 800 Enclosure without Front Control Panel 930-0371 Hardened Enclosure with backplane panel and blank card faceplates. Interface Card Axxius 800 Enclosure Front Control Panel Interface Hardened Front Control Panel Interface Card, provides Controller Interfaces for Management and Network Interfaces, 4 x 740-0083 Card T1 and 2 DS3 SMB. Interfaces active based on installed controller. Hardened 24VDC Power Supply Card - One power supply card minimum required per system. Two 24V power supply 24VDC Power Supply Card 740-0080 cards may be installed for redundancy. Note: 24 and 48V power supply cards cannot be mixed in the same system. Hardened 48VDC Power Supply Card - One power supply card minimum required per system. Two 48V power supply 48VDC Power Supply Card 740-0081 cards may be installed for redundancy. Note: 24 and 48V power supply cards cannot be mixed in the same system. Hardened -48VDC Power Supply Card that provides -48VDC power to system backplane. This power supply is required NI48VDC Power Supply Card 740-0084 to support the FXO and OCU-DP cards - One power supply card minimum required per system. Two power supply cards may be installed for redundancy. Note: 24 and 48V power supply cards cannot be mixed in the same system. Hardened 4-Port T1 Controller Card - One controller card minimum required per system. Two controller cards may be Quad T1 TDM Controller Card 740-0073 installed for redundancy. Includes SNMP & RPM management features. Note: T1 and DS3 Controller cards cannot be mixed in the same system. Hardened Dual Port DS3 Controller Card - One controller card required per system. Two controller cards may be installed Dual DS3 TDM Add-Drop Controller Card 740-0074 for redundancy. Includes SNMP & RPM management features. Note: T1 and DS3 Controller cards cannot be mixed in the same system. 11-006 Form #CF-118, Rev. C Page 4 Updated 5/12/04 Item Part Number Description Hardened Two-channel V.35 data card with V.54 loopback and BERT Test Capability. Requires Controller software Dual V.35 Card with V.54 Test Capability 740-0076 release 1.0 or later. Single port POTS card with on-board V.34 Dial-up modem for remote dial-in management access. Requires Controller Single Channel POTS Card with Modem 740-0077 software release 1.0 or later. Hardened Single port POTS card for providing order-wire analog voice connection at a cell site. Requires Controller Single Channel POTS Card 740-0078 software release 1.0 or later. Hardened 4-port terminal server router card, supporting all Quad Terminal Server Router card functions, Raw TCP and Quad Terminal Server Router Card with TBOS-to- TBOS-to-SNMP Alarm conversion for Alcatel microwave radios – Model 4000 and Proxim microwave radios– Lynx SC 740-0098 SNMP Alarm Conversion and HD series, 3100 series (3100,31600, 31650, 31800). Each port is strap selectable for 10/100BaseT or RS-232 asynchronous data operation. Requires Controller software release 2.0 or later. Low Speed Protection Card for relay card slot. Provides 1:7 interface/card protection for Quad T1 cards via rear wire Low Speed Protection Card 740-0087 wrap connections. Note: Minimum controller software release required is Rev. 1.2. Requires Quad T1 card firmware release 2.0 or higher. Service & Controller Card Slot Blank Faceplate 710-0162 Blank faceplates for empty service card and controller card slots. Broadband Card Slot Blank Faceplate 710-0164 Blank faceplates for empty broadband card slots. Power Supply Card Slot Blank Faceplate 710-0163 Blank faceplates for empty power supply card slots. Axxius 800 / Adit 600 Service Cards 8 channel expansion or replacement card for FXO or DPT interface applications. FXO-8 Card 740-0037 Note: Minimum controller software release required is Rev. 1.2.2 for Adit 600 and Rev. 1.1 for Axxius 800 (Requires Axxius 800 power supply P/N 740-0084) Two-channel ISDN BRI card for 3DS0 LULT or LUNT applications. Note: Minimum controller software release required is Dual ISDN BRI Card 740-0041 Rev. 1.2.2 for Adit 600 and Rev. 1.1 for Axxius 800 Eight-channel ISDN BRI card for 3DS0 LULT or LUNT applications. Note: Minimum controller software release required Octal ISDN BRI Card 740-0042 is Rev. 1.2.2 for Adit 600 and Rev. 1.1 for Axxius 800 Four-channel ISDN BRI card for 3DS0 LULT or LUNT applications. Note: Minimum controller software release required is Quad ISDN BRI Card 740-0048 Rev. 1.2.2 for Adit 600 and Rev. 1.1 for Axxius 800 Single port all rate OCU-DP Card for DDS Service delivery applications. Note: Minimum controller software release Single OCU-DP Card 740-0066 required is Rev. 3.2.0 for Adit 600 and Rev. 1.1 for Axxius 800 (Requires Axxius 800 Power Supply P/N 740-0084) Quad port all rate OCU-DP Card for DDS Service delivery applications. Note: Minimum controller software release Quad OCU-DP Card 740-0067 required is Rev. 3.2.0 for Adit 600 and Rev. 1.1 for Axxius 800 (Requires Axxius 800 Power Supply P/N 740-0084) Quad DS1/E1 Card 740-0075 Hardened Four channel T1 card for voice and data applications. Requires Controller software release 1.0 or later. Hardened 4-port terminal server router card, supporting IP/IPX routing and layer 2 bridging. Each port is strap selectable Quad Terminal Server Router Card 740-0079 for 10/100BaseT or RS-232 asynchronous data operation. Requires Controller software release 1.0 or later. Quad port ADPCM Card for transcoder applications, provides 32Kbps ADPCM voice compression on Port 1. Note: Quad DS1 ADPCM Card 740-0091 Minimum controller software release required is Rev. 2.0. Axxius 800 Accessories 19-inch rack mount brackets and hardware for mounting Axxius 800 Enclosure in 19-inch rack, utilizes 2 RU of vertical 19-inch Rack Installation Kit 710-0165 rack space 23-inch rack mount brackets and hardware for mounting Axxius 800 Enclosure in 23-inch rack, utilizes 2 RU of vertical 23-inch Rack Installation Kit 710-0166 rack space Axxius 800 User Manual (CD-ROM) 770-0103 CD ROM version of Axxius 800 usr manual. Included with each system. Axxius 800 User Manual (Hard Copy) 770-0104 Paper version of the Axxius 800 user manual. Axxius Quad TSR Card User Manual 770-0105 Axxius Quad TSR card user manual Remote Valet User Manual 770-0106 Remote Valet software user manual Remote Valet Software CD 750-0040 Remote Valet software for TSR remote OMT applications 11-006 Form #CF-118, Rev. C Page 5 Updated 5/12/04 Item Part Number Description Axxius Intra Office Connector Kit for 26 AWG wire. Includes 16 insulation displacement connectors, 16 connector caps Axxius Intra Office Connector Kit (26 AWG) 710-0167 and a tool for inserting wire into connectors for providing insulation protection for the rear wire wrap pins Axxius 800 Installation Accessory Kit: Includes (2) 10-32 nuts, (2) 6 position screw terminals, (1) ground lug connector Axxius 800 Installation Accessory Kit 710-0168 pressure terminal, (2) 2 position plug right angle, wiremount, and (2) 10 position, plug right angle wiremount. This accessory kit shipped with every configured system for power, ground and alarm wiring connectors. Axxius Intra Office Connector Kit for 24 AWG wire. Includes 16 insulation displacement connectors, 16 connector caps Axxius Intra Office Connector Kit (24 AWG) 710-0169 and a tool for inserting wire into connectors for providing insulation protection for the rear wire wrap pins Axxius DC power input protective shroud kit provides two protective covers for the VDC power input connectors. These Axxius DC Input Protective Shroud Kit 790-0027 are required to meet UL Safety compliance for installing Axxius units in non-restricted access areas. Universal Accessories Null Modem Adapter 005-0002 25-pin male/25-pin male DB-9 to DB-25 Female Adapter 005-0007 DB-9 to DB-25 female adapter Serial Console Cable - 12 ft. 005-0064 12 ft. serial console cable with a DB-9 female and DB-9 male V.35 Data Cable - 10 ft. male V.35/male Winchester 005-0008 10 ft. V.35 Data Cable - male V.35 / male Winchester V.35 Data Cable - 10 ft. male V.35/female Winchester 005-0014 10 ft. V.35 Data Cable - male V.35 / female Winchester V.35 Data Cable - 25 ft. male V.35/female Winchester 005-0068 25 ft. V.35 Data Cable - male V.35 / female Winchester V.35 Data Cable - 50 ft. male V.35/female Winchester 005-0069 50 ft. V.35 Data Cable - male V.35 / female Winchester V.35 Data Cable - 25 ft. male V.35/male Winchester 005-0009 25 ft. V.35 Data Cable - male V.35 / male Winchester V.35 Data Cable - 50 ft. male V.35/male Winchester 005-0010 50 ft. V.35 Data Cable - male V.35 / male Winchester T1 Cable - 25 ft. 005-0101 25 ft. RJ48C-to-RJ48C T1 Straight Cable, RJ45 plug on each end T1-Cable - 2 ft. 005-0183 2' RJ48C-RJ48C T1 Cable, Straight-Through, RJ48 plug on each end Ethernet Crossover Cable - 2 ft. 005-0102 2 ft. RJ45-to-RJ45 Ethernet Crossover Cable, RJ 45 plug on each end Ethernet Straight Cable - 6 ft. 005-0103 6 ft. RJ45-to-RJ45 Ethernet Straight Cable, RJ 45 plug on each end RJ48C (Jack) to DB15P (Male) T1 Connector Adapter RJ48C-to-DB15P T1 Connector Adapter wired for Ericsson BTS (RJ48C pin 1 to DB15 pin 1, RJ48C pin 2 to DB15 pin 2, 005-0104 for Ericsson Applications RJ48C pin 4 to DB15 pin 7, RJ48C pin 5 to DB15 pin 6) DB15P (Male) to RJ48C Jack Connector Adapter with DB15P-to-RJ48C Jack Connector Adapter with jack-posts wired for Nortel BTS CSU replacement (RJ48C pin 1 to DB15 005-0185 jack-posts for Nortel BTS pin 11, RJ48C pin 2 to DB15 pin 3, RJ48C pin 4 to DB15 pin 9, RJ48C pin 5 to DB15 pin 1) DB15S (Female) to RJ48C Jack Connector Adapter DB15S-to-RJ48C Jack Connector Adapter with jack-posts wired for Nortel BTS CSU replacement (RJ48C pin 1 to DB15 005-0184 with jack-posts for Nortel BTS pin 9, RJ48C pin 2 to DB15 pin 1, RJ48C pin 4 to DB15 pin 11, RJ48C pin 5 to DB15 pin 1) RJ45-to-DB9P Connector Adapter 005-0106 RJ45-to-DB9P Connector Adapter - for Quad TSR Card RS-232 asynchronous data applications DS3 Cable - 10 ft. BNC Female-to-SMB Plug 005-0158 DS3 Cable, BNC Female-to-SMB Plug, 10 Feet DS3 Cable - 5 ft. BNC Female-to-SMB Plug 005-0159 DS3 Cable, BNC Female-to-SMB Plug, 5 Feet DS3 Cable - 10 ft. SMB Plug-to-SMB Plug 005-0160 DS3 Cable, SMB Female-to-SMB Plug, 10 Feet DS3 Cable - 5 ft. SMB Plug-to-SMB Plug 005-0161 DS3 Cable, SMB Female-to-SMB Plug, 5 Feet DS3 Cable - 5 ft. BNC Male-to-SMB Plug 005-0162 DS3 Cable, BNC Male-to-SMB Plug, 5 Feet DS3 Cable - 10 ft. BNC Male-to-SMB Plug 005-0164 DS3 Cable, BNC Male-to-SMB Plug, 10 Feet Grayson LMU V.35 Adapter Cable 005-0186 6' Cable Right Angle DB-25S (Female) to SCSI-26 (male) with Latches Grayson LMU V.35 Adapter Cable 005-0187 10' Cable Right Angle DB-25S (Female) to SCSI-26 (male) with Latches Grayson LMU V.35 Adapter Cable 005-0188 25' Cable Right Angle DB-25S (Female) to SCSI-26 (male) with Latches Grayson LMU V.35 Adapter Cable 005-0189 50' Cable Right Angle DB-25S (Female) to SCSI-26 (male) with Latches Included Items 11-006 Form #CF-118, Rev. C Page 6 Updated 5/12/04 Item Part Number Description Axxius 800 Chassis with the Control Panel Interface Card Includes: • Two Power Supply Slots • Two Controller Cards Slots • Two Broadband Card Slots • Eight Service Card Slots • One T1/E1 Interface Protection Relay Card Slot • Two rear power input connectors • Two rear BITS clock input connectors • Front Female DB-9 RS-232 Management Port • Front RJ-45 10BaseT port for Ethernet management • Four Front RJ-48C DS1/E1 Interface Ports (Active when Quad DS1 Controller Installed) • Two Front SMB DS3 Interface Ports (Active when Dual DS3 Controller Installed) • Sixteen rear wire-wrap pins per service card slot • Two 6-pin alarm relay output connectors. 3 Audible and 3 Visible (Critical, Major and Minor) • Two 10-pin environmental alarm relay input connectors • Axxius 800 user's manual on CD-ROM • Axxius 800 blank card face plates • Axxius 800 Accessories Kit • 19- and 23-inch Rack Mounts 11-006 Form #CF-118, Rev. C Page 7 Updated 5/12/04

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the 005-0064?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

-48VDC circuit breaker panel, 5 pos. w/4 pairs (A/B feeds) 5 Amp breakers, 19/23-inch mount (Hendry)

-48VDC circuit breaker panel, 7 pos. w/4 pairs (A/B feeds) 5 Amp breakers, 19-inch mount (Telect)

ACCESS QUAD FRAMER CD

product

Adit 600, +24V Chassis, power supply, Dual T1 TDM controller, SNMP & RPM management, 5 blank card fa...

product

CARRIER ACCESS HT01BD236C TRANSFORMER

product

Carrier Access PWA-003-0172 QUAD T1 CARD.