BPS BPS-300SP (2U) Power Supplies-300W ATX 1U Single 100-240VAC Input AC/DC, 12V Max 10A Current Power Supply

Part Number

BPS-300SP (2U)

Price

Request Quote

Manufacturer

BPS

Lead Time

Request Quote

Category

Power Supply

Specifications

Efficiency

68%/115V; 68%/230V(full load)

Hold-up time

20mx at 115Vac/60Hz, 20ms at 230Vac/50Hz.

Input current

8.0A/115Vac, 4.0A/230Vac

Input frequency

47 to 63Hz

Input voltage

90 to 264 VAC

MTBF

100,000hours at full load at 25°C

Operating temperature

0°C to +50°C

Output V2

Voltage-3.3V;Max Load-20A;Min Load-0A;Max Power-150W;Load Regulation-+/-5%;Cross Regulation-+/-5%;Line Regulation-+/-1%;Ripple/Noise-+/-1%

Output V3

Voltage-+12V;Max Load-12A;Min Load-1A;Max Power-150W;Load Regulation-+/-5%;Cross Regulation-+/-5%;Line Regulation-+/-1%;Ripple/Noise-+/-1%

Output V4

Voltage- -5V;Max Load-0.5A;Min Load-0A;Max Power-2.5W;Load Regulation +/-10%;Cross Regulation-+/-10%;Line Regulation-+/-1%;Ripple/Noise

Output V5

Voltage- -12V;Max Load-1A;Min Load-0A;Max Power-12W;Load Regulation-+/-10%;Cross Regulation-+/-10%;Line Regulation-+/-1%;Ripple/Noise-+/-1%

Output V6

Voltage-Standby;Max Load-1.5A;Min Load-0A;Max Power-7.5W;Load Regulation-+/-5%;Cross Regulation-+/-5%;Line Regulation-+/-1%;Ripple/Noise-+/-1%

OutputV1

Voltage-+5V;Max Load-30A;Min Load-3A;Max Power-150W;Load Regulation-+/-5%;Cross Regulation-Line Reg-+/-1%;Ripple-+/-1%

Relative humidity

5% to 95% non-condensing

Storage temperature

-20°C to +80°C

Features

Datasheet

pdf file

BPS-BPS-300SP-2U-ds1-796098532.pdf

205 KiB

Extracted Text

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C. Tel: 886-2-8647-1188 Fax: 886-2-8647-3322 1.0 General 1.1 Parameter Specifications 2.0 Input Characteristics 2.1 Input Voltage 2.2 Input Waveform 2.3 Input Frequency 2.4 Input Current 2.5 In-Rush Current 2.6 Line Regulation 2.7 Input Leakage Current 2.8 Isolation (Hi-Pot) 3.0 Output Characteristics 3.1 DC Output Characteristics 3.2 Overshoot 3.3 Efficiency 4.0 Time Sequence 4.1 Hold-Up Time 4.2 Power Good Signal 4.3 +5 Volt & +3.3V Power Good Output Rise Time 4.4 Start-Up Time 4.5 Dynamic Load Response Time 5.0 Protection 5.1 Over Power Protection 5.2 Over Voltage Protection 5.3 Short Circuit Protection 5.4 No Load Operation 5.5 5VSB (Standby) 5.6 PS-ON (Remote ON/OFF) 5.7 3.3V Sense 6.0 Physical Characteristics 6.1 Size 6.2 Mounting Requirements 6.3 Weight 6.4 Cooling 7.0 Connectors 7.1 DC Output Wire List 7.2 AC Input 8.0 Environmental 8.1 Temperature 8.2 Relative Humidity 8.3 Altitude 8.4 Shock 8.5 Vibration 8.6 Power Line Transient 8.7 Acoustic Noise 9.0 Regulatory Agency Certification 9.1 RFI/EMI Standards 9.2 Safety Standards 10.0 Reliability 10.1 Mean Time Between Failures (MTBF) 10.2 Warranty 1.0 General This specification describes the physical, functional and electrical characteristics of a single power 300 watts, 6-output, fan-cooled switching power supply with Active PFC function. 1.1 Parameter Specifications Unless specified otherwise, all parameters must be met over the limits of temperature, load and input voltage. 2.0 Input Characteristics 2.1 Input Voltage Input voltage range set with FULL RANGE (110 ~ 240VAC). 2.2 Input Waveform The unit is capable of operating with a 10% distorted sinewave input as measured by a distortion analyzer. Its flattopping clipped 10% from the peak value of standard sinewave. 2.3 Input Frequency 47 Hz to 63 Hz 2.4 Input current 430W Input Power Vin: 110VAC 6 A Vin: 240VAC 3.5 A 2.5 In-Rush Current CONDITIONS LIMITS 110 - 240VAC, Full load. No damage shall occur or Turn off 1 sec; turn on at components over stressed, peak of input voltage cycle. input fuse shall not blow. 25℃ Air Ambient cold start. 2.6 Line Regulation CONDITIONS LIMITS Full load, +/1% 110 - 240VAC input 2.7 Input Leakage Current Input leakage current from line to ground will be less than 3.5 mA rms. Measurement will be made at 240 VAC and 60Hz. 2.8 Isolation (Hi-pot) 1500VRMS, 50Hz, for one (1) minute between each input AC line and the grounding conductor. 3000VRMS, 50Hz, for one (1) Minute between the input AC lines and secondary low voltage outputs and shields. All isolation transformers will have been tested prior to assembly into a power supply unit. Any such transformers without a grounded shield will be tested to 3750 VRMS. 3.0 Output Characteristics 3.1 DC Output Characteristics To be met under all combinations of loading. Output V1 V2 V3 V4 V5 5VSB Voltage +5V 3.3V +12V -5V -12V Standby Max. Load 30A 20A 12A 0.5A 1A 1.5A Min. Load 3A 0A 1A 0A 0A 0A Max. Power 150W 2.5W 12W 7.5W 278W Load Reg. % +/-5% +5/-3% +/-5% +/-10% +/-10% +/-5% Cross Reg. % +/-5% +5/-3% +/-5% +/-10% +/-10% +/-5% Line Reg. % +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-2% +/-2% +/-1% Ripple % +/-1% +/-1% +/-1% +/-2% +/-2% +/-1% Noise % Note 1: The +12 Volt output of the power supply must be capable of 15 Amps peak for 10 seconds. A +/-5% tolerance is permissible. Output voltage is measured at the load and of the output cable. Note 2: Noise bandwidth is from DC to 20 MHz. Note 3: Regulation tolerance shall include temperature change, warm up drift and dynamic load. 3.2 Overshoot Any output overshoot at TURN-ON shall not exceed 5% (+5V/+12V/+3.3V outputs) and 10% (-5V/-12V outputs) of nominal voltage value. 3.3 Efficiency 70% min. at full load test. 4.0 Time Sequence 4.1 Hold-Up Time Unit shall continue to supply regulated DC outputs and power good signal for at least 20 milliseconds at 110 ~ 240VAC full load after a loss of AC input voltage which shall be represented by a short circuit at the AC input. 4.2 Power Good Signal When the power supply is turned off for a minimum of 1.0 second and turned on, the power-good signal as described below will be generated. The power supply shall provide a power-good signal to indicate proper operation of the power supply. This signal shall be a TTL compatible high level for normal operation; low level for fault conditions. Power-good shall go to a low level at least 1 ms before the +5V output voltage falls below the regulation limits described in 3.1 DC output Characteristics. The operation point used as a reference for measuring the 1ms shall be minimum line voltage and maximum load. All waveform transitions shall be smooth and monotony, i.e. no oscillations. The power-good signal shall stay low (during POWER-ON) until all output voltages are stable within regulation limits. The power-good signal shall have a TURN-ON delay greater than 100 ms but less than 500 ms. 4.2.1 Fan-out Power-Good output circuit shall consist of an active pull down component and a passive pull up resistor. Power-Good output voltage to be met under recommended loading conditions. CONDITIONS LIMITS IoH= -140uA Min. VoH= 2.7V Min. IoL= 2.8mA Min. VoL= 0.4V Min. 4.3 +5 V & +3.3V and Power Good Outputs Rise Time 4.3.1 +5 V & +3.3V Output Rise Time The +5 Volt and +3.3 Volt output shall have a turn-on rise time of less than 100ms under all load conditions. Rise time is measured between 0.0 and 2.48/4.75 volts. The +5 V and +3.3V output shall not vary from a smooth curve by more than 0.5 VP-P during turn-on and turn-off. +5v, +3.3V 0.5Vp-p 0.5Vp-p max. max. Rise Time < 5us 2.5v P/G CV 4.4 Start-up timing All outputs shall be stable and in regulation in less then 2.0 second under all load and line conditions. Start-up time is measured between the AC turn-on and 4.75 volts on +5v output. 4.5 Dynamic Load Response Time Transient response is measured by switching the output load from 80 to 100 to 80 percent of its full value at a frequency of 100 Hz and 50% duty cycle, step load change is 0.5A/us, The magnitude Vr is less than +/- 5% of +5V and +12V outputs, the recovery time Tr is less than 1ms. 5.0 Protection 5.1 Over Power Protection This power supply shut down all DC outputs when +5 Vdc and +12 Vdc outputs are overloaded to the limit. The power supply logic shall latch into the off state requiring a power on cycle to be performed by the operator. The power supply will turn-off within 20 ms of the occurrence of the overload. The -5 Vdc and -12 Vdc outputs will be internally current limited. CONDITIONS LIMIT 110 -240 VAC input When output power is over to 120% 5.2 Over Voltage Protection The power supply shall latch off if the +5 VDC or 3.3VDC or +12 VDC maximum voltage exceeds the limits shown. The AC must be recycled to restart. +5 VDC CONDITIONS LIMITS All operating 6.25 VDC +/- 0.65 VDC +3.3 VDC CONDITIONS LIMITS All operating 4.10 VDC +/- 0.40 VDC +12 VDC CONDITIONS LIMITS All operating 13.6 - 15.6 VDC 5.3 Short Circuit Protection A short circuit placed on any output shall cause no damage to this unit. 5.4 No Load Operation When primary power is applied, with no load on any output voltage, no damage or hazardous conditions shall occur. In such a case, the power supply shall power up and stabilize. However, minimum load required 3A for +5V and 1A for +12V. 5.5 5VSB (Standby) The 5VSB output is always on (+5V Standby) when AC power is applied and power switch is turned on. The 5VSB line is capable of delivering at a maximum of 5A for PC board circuit to operate. 5.6 PS-ON (Remote ON/OFF) PS-ON is an active low signal that turns on the entire main power rail including 3.3V, 5V, -5V, 12V & -12V power rails. When this signal is held by the PC board or left open circuited, outputs of the power rails should not deliver current and should be held at a zero potential with respect to ground. Power should only be delivered to the rails if PS-ON signal is held at ground potential. This signal should be held at +5VDC by a pull-up resistor internal to the power supply. Power On P1-PIN #14 Power Switch P1-PIN #14 PS-ON PS-ON ON L ON IN OFF H ON IN OFF X ON OUT OFF X OFF X 5.7 3.3V Sense A remote 3.3V sense line can be added to the P1 connector Pin2 to allow for accurate control of the 3.3VDC line directly at motherboard loads. Due to potential voltage drops across the connector and traces leading to the motherboard components, it may be advantageous to implement a 3.3V sense line that remotely monitors the 3.3VDC power level at the load on the motherboard. 6.0 Physical Characteristics 6.1 Size 100*70*190mm 6.2 Mounting Requirements See Figure 6 6.3 Weight 1.4 Kg 6.4 Cooling Fans: SUNON (KD1206 PTV1), or equivalent or better. Air flow from the power supply should be in exhaust direction and shall be rated at 36 cfm minimum. 7.0 Connections 7.1 DC Output Wire List → + For ATX Mother Board Connector Output Wire Color Wire Size ATX 20 PIN P1-1 +3.3V BRN 16 AWG P1-2 +3.3V BRN 16 AWG P1-3 GND BLK 18 AWG P1-4 +5V RED 18 AWG P1-5 GND BLK 18 AWG P1-6 +5V RED 18 AWG P1-7 GND BLK 18 AWG P1-8 PW-OK ORG 18 AWG P1-9 5VSB PURPLE 18 AWG P1-10 +12V YEL 18 AWG P1-11 +3.3V BRN 16 AWG P1-12 -12V BLUE 18 AWG P1-13 GND BLK 18 AWG P1-14 PS-ON GRN 18 AWG P1-15 GND BLK 18 AWG P1-16 GND BLK 18 AWG P1-17 GND BLK 18 AWG P1-18 -5V WHT 18 AWG P1-19 +5V RED 18 AWG P1-20 +5V RED 18 AWG 4 PIN 12V for P4 Pn-1 COM BLK 18 AWG Pn-2 COM BLK 18 AWG Pn-3 +12V YEL 18 AWG Pn-4 +12V YEL 18 AWG P11、P12 P1-1 +5V RED 22 AWG P1-2 COM BLK 22 AWG P1-3 COM BLK 22 AWG P1-4 +12V YEL 22 AWG P13、P14 Pn-1 +12V YEL 18 AWG Pn-2 COM BLK 18 AWG Pn-3 COM BLK 18 AWG Pn-4 +5V RED 18 AWG P15、P16 Pn-1 +12V YEL 18 AWG Pn-2 COM BLK 18 AWG Pn-3 COM BLK 18 AWG Pn-4 +5V RED 18 AWG P17、P18 Pn-1 +12V YEL 18 AWG Pn-2 COM BLK 18 AWG Pn-3 COM BLK 18 AWG Pn-4 +5V RED 18 AWG 7.2 AC Input IEC 320 power inlet with EMI filter. 8.0 Environmental 8.1 Temperature 8.1.1 Operating 50 to 122 °F (0 to 50 °C). Derate Linearly to 50% at 70 °C 8.1.2 Non-Operating -4.0 to 140 °F (-20 to 60°C) 8.2 Relative Humidity 8.2.1 Operating 20 to 90 % non-condensing at 104°F (40 °C). 8.2.2 Non-Operating 5 to 95 % non-condensing at 122°F (50°C). 8.3 Altitude 8.3.1 Operating Sea level to 10,000 feet. 8.3.2 Non-Operating Sea level to 40,000 feet. 8.4 Shock 8.4.1 Operating The power supply shall exhibit no sings of damage or degradation of performance when subjected to a shock of 5g`s for 11 ms, with a 1/2 sine wave for each of the perpendicular axes X, Y and Z. 8.4.2 Non-Operating The power supply shall exhibit no sings of damage or degradation of performance when subjected to a shock of 30g's for 11 ms, with a 1/2 sine wave for each of the perpendicular axes X, Y and Z. 8.5 Vibration 8.5.1 Operating The power supply shall be subjected to a vibration test consisting of a 10 to 500 Hz sweep at a constant acceleration of 0.5g for duration of one (1) hour for each of the perpendicular axes X, Y and Z. The output voltages shall remain within specification. 8.5.2 Non-Operating The power supply shall be subjected to a vibration test consisting of a 10 to 300 Hz sweep at a constant acceleration of 2.0g for duration of one (1) hour for each of the perpendicular axes X, Y and Z. The power supply shall not incur physical damage or degradation of any characteristics below the performance specifications. 8.6 Power Line Transient 8.6.1 Drop Out With a full cycle input voltage drop-out at 50Hz, the unit shall operate within the prescribed voltages with a drop-out cycle repetition rate of 500ms. CONDITIONS LIMITS Full load, Nom. Input AC Voltage Meet all requirements 8.6.2 Transient Voltage Spikes The unit shall meet the following standards, The IEEE Standard 587-1980 for surge withstand capability under categories A and B. The crest value of the first half peak of the injected Ringwave (0.5/10us) and Biwave (1.2/50us) will be 3K volts open circuit and 3KA (8us×20us) short circuit. IEC 801-2 (ESD) to a level of 8KV contact, and 15K air discharge without causing the device(s) to fail the test. IEC 801-4 (EFT) on the power lines and all I/O cables to a level of 2.5KV without causing the Device(s) to fail the test. IEC 801-5 Surge immunity measurement on the input power source of 2.5KV. All output shall be stable and in regulation. 8.7 Acoustic Noise The power supply shall be tested in accordance with the ANSIS12.10-1985 standard specifications. The "A" weighted overall sound pressure level as well as individual octave band levels from 63 Hz to 16,000 Hz is measured with the noise meter placed 1 meter from the nearest vertical surface of center of fan installed in power supply. CONDITIONS LIMITS 115 VAC Input, full load of +5V Acoustic noise is 40 db maximum 0.5A of +12V. Octave Band Center Frequency (Hz) A-Weighted 125 250 500 1k 2k 4k 8k 16k Max. Sum 20 36 42 42 42 36 30 20 40dBA 9.0 Regulatory Agency Certification 9.1 RFI/EMI Standards The power supply, when installed in system, shall meet with the following radiated and conducted emissions standards: a) FCC part 15, Subpart A, Class A computing devices. b) CISPR22 (EN55022) Class A. c) VCCI Class 2. These limits shall be met with a margin of at less 6dB at all applicable frequencies. The unit shall comply with the above limits when tested under all normal working conditions and with all interface cables connected. 9.2 Safety Standards The power supply shall be meets with the following safety standards, a) UL 1950 (Information Processing/Business equipment). b) CSA C22.2, NO. 234-M90 level 6 (Safety of component, power supplies) or CSA C22.2, NO. 950-M89. st c) TUV Certification to IEC 950 1 edition with Amendment #1, #2, and EN60950 d) CB Certificate & Test report deviation for the Nordic countries. e) CE Certificate & Test report. 10.0 Reliability 10.1 Mean Time Between failures (MTBF) Using MIL217E the calculated MTBF = 100,000 hours at 25°C 10.2 Warranty Two (2) years manufacture's warranty Date code indicating week and year of manufacture.

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the BPS-300SP (2U)?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

BPS BPS-230DS/2U Power Supply. 230W | 2U Single ATX 24VDC(17-36VDC) 15A Input DC/DC | 12V Max Curren...

product

BPS BPS-2504-4TU Power Supply. 250W | ATX | 70% Efficient at full load

product

BPS BPS-250DS Power Supply. 250W | 1U Single ATX | -48VDC Input DC/DC | 12V Max 10A Current

product

BPS BPS-250DS/1U Power Supplies - 250W 1U Single ATX -48VDC Input DC/DC, 12V Max 10A Current Power S...

product

BPS-250DSP/24 - Power Supply | 250W ATX 24VDC input | +5 V & +3.3V Output Rise Time

product

BPS BPS-250DSP/24V Power Supply. 250W | AT | PS/2 Style