Specifications

Number of Areas

8

Number of Card Readers (Doors)

2

Number of Credentials (Tokens)

396

Number of Custom Functions

4

Number of Events

Store up to 1,000

Number of Hardware Addresses

75

Number of Parallel Printers

1

Number of Passcode Users

99, plus 1 service passcode

Number of Points

75 (8 on-board, up to 67 off-board)

Number of Programmable Relay Outputs

67

Number of RF Points

67

Number of SKEDs

40

Features

Datasheet

pdf file

D7412GControlPa_DataSheet_enUS_T154410650-11073881547.pdf

947 KiB

Extracted Text

Intrusion Systems | D7412G Control Panel D7412G Control Panel ▶ Digital communicator with phone line monitor (loop or ground start) ▶ Multiple telephone numbers, primary and duplicate paths with main and alternate destinations All reports within each of four route groups are ▶ programmable ▶ Optional dual phone line switcher monitors two phone lines ▶ Optional network interface module for two-way communication over Ethernet networks Automatic test and status reports ▶ ▶ Time windows for arming and open and close report suppression Programmable answering machine solution for remote ▶ programming on shared phone lines The D7412G Control Panel provides an integrated solution The D7412G Control Panel provides up to 75 individually for Access Control, Security, and Fire Alarm system identified points. Each point accommodates normally open applications. The control panel is capable of monitoring (NO) and or normally closed (NC) devices with end-of-line alarm points for intruder or fire alarms while operating user (EOL) resistor supervision. Each point is programmable for command centers and other outputs. The control panel fire, fire supervisory, or burglary applications. includes a communicator that reports events to selected System Response PSTN or IP network destinations through four 31 custom point indexes, including fire supervisory • programmable route groups. Programming and accessory Selectable point response time • Cross point compatibility modules offer flexibility and beneficial features rarely found • Fire alarm verification • in other security control systems. Fire inspector’s local test • The D7412G Control Panel provides eight on-board points, Watch mode • up to 67 off-board points, 64 relays, and two access control Scheduled events (skeds) arm, disarm, bypass and • unbypass points, control relays, control authority levels, doors. Grant access from a Wiegand style card reader and control door access connected to: a D9210B Access Control Module, a request- User Interface to-enter or request-to-exit input, or a keypad. Supervises up to eight command centers or keypads (up • to 32 non-supervised command centers or keypads can be used) Functions Custom command center text • Full function command menu including custom • Programmable Outputs functions 2 A alarm power at 12 VDC • Each user has authority by area and 16-character name • 1.4 A auxiliary power at 12 VDC • 14 custom authority levels control user’s authority to • Four alarm output patterns • change, add, delete passcodes or access control Automatic bell test • tokens/cards, disarm, bypass points, and initiate Programmable bell shut-off timer • system tests www.boschsecurity.com 2 | D7412G Control Panel Adjustable brightness or volume for keypad display or • periodically using one phone call, rather than receiving sounder several calls each day. When the control panel’s event log reaches the storage limit, it can send a report to a receiver. Note At least one keypad per system is recommended. Access events that you can store, view or print include: Access granted Area Configurations • No entry • Area programming offers a wide selection of different Request-to-enter • system configurations. Each area is assigned an account Request-to-exit • number to define annunciation, control, and reporting Access Control functions. Multiple areas can be linked to a shared area Custom door strike, point shunt and auto disarming • which is automatically controlled (hallway or lobby). Area response by area arming can be conditional on other areas (master or Logging options for: Access Granted, No Entry, • associate). Request-to-exit, and Request-to-enter 14 panel-wide access levels with both manual and • User Passcodes scheduled control User passcodes contain three to six digits. Each user is Scheduled Events (Skeds) assigned one of 14 customized authority levels in each area. The D7412G Control Panel's internal clock and calendar Passcodes can be restricted to operate only during certain helps to operate individually scheduled events (skeds). times. User names can contain up to 16 characters. The user Skeds perform a specific function such as arm/disarm, relay name can be viewed, printed, reported to a central station control, or point bypassing. The D7412G Control Panel 2 in Modem IIIa Communications format or retrieved with offers: Remote Programming (RPS) software. 40 scheduled events with up to 26 different functions • Security and Fire Detection 16 open or closing windows • The D7412G Control Panel provides eight on-board points, Eight user windows • Day-of-week, date-of-year, or holiday only schedules and up to 67 additional off-board points (depending on • Four holiday schedules of 366 days each (leap year) • model and expansion interfaces). Program individual points to monitor all types of burglar alarm, fire alarm, and Fire Test supervision devices. When a user activates Fire Test Mode, the control panel suppresses all reports to the central station. Use a Communications passcode at the keypad to activate Fire Test Mode. The The D7412G has four route groups. It can sort reports by keypad and annunciator show all testing data. An automatic priority and transmit reports to four route groups each of sensor reset feature saves time; you do not need to reset which has a programmable primary and backup destination. the sensors manually. At the end of test, the keypad shows The D7412G is compatible with the D6600 NetCom the number of untested points. Communications System using a DX4020 Network Interface Programming, Diagnostics and Controls Module. It has programmable anti-replay anti-substitution Users can program all system functions on-site with a when using a DX4020. D5200 Programmer, or remotely through RPS. A 2 The Modem IIIa Communications Format, available with programmable system passcode prevents unauthorized Bosch receivers, adds reporting capabilities such as: remote programming. Individual point numbers and text • The control panel accommodates up to four separate Opening or closing reports by area number, user • telephone numbers for primary, alternate and backup number, and user text Remote programming attempts receivers for automatic test reports. • Diagnostic reports • When resetting alarms, arming or disarming a combination Event Log Storage, Viewing and Printing fire/burglary and/or access control system, the user is All local and transmitted events (up to 1,000 total events) identified by name and number. are stored in a log. The event log includes time, date and event, with area, point and user number. You can view the event log from select keypads or remotely retrieve event information using RPS. With the printer interface module installed, the D7412G Control Panel allows the use of one on-site parallel printers. The Event Log and a local printer provide a record of openings and closings without extra communications costs. RPS operators can retrieve events D7412G Control Panel | 3 Certifications and Approvals Keypads D1260 Series Keypads (D1260, D1260W, D1260R, D1260BLK, D1260B) Magnetic Con- All Bosch magnetic contacts, including recessed, termi- Region Certification tacts nal connection, miniature, overhead door, and surface USA UL AMCX: Central Station Alarm Units mount. (UL1610, UL1635), AOTX: Local Alarm Bells D440 Bell 12 V, 15 cm (6 in.) Units (UL464, UL609), APAW: Police D441 Bell 24 V, 15 cm (6 in.) Station Alarm Units (UL365, UL464), APOU: Proprietary Alarm Units (UL1076), MB-G10-12-R Bell 12 V, 25.4 cm (10 in.) NBSX: Household Burglar Alarm System MB-G10-24-R Bell 24 V, 25.4 cm (10 in.) Units (UL1023), UOJZ: Control Units, Modules C900V2 Dialer Capture Module System (UL864, 9th edition), UTOU: D125B Dual Class B Initiating Module Control Units and Accessories - Household System Type (UL985) D127 Reversing Relay Module D129 Class A Initiating Module FM D130 Auxiliary Relay Module CSFM 7165-1615: 119 D136 Plug-in Relay FCC AJ9-MUL-46532-AL-E D185 Reverse Polarity Signaling Module NYC-MEA 12-92-E, Vol. XII D192C Notification Appliance Circuit Module Brazil ANATEL 0049-03-1855 D192G Notification Appliance Circuit Module D8121A Derived Channel S.T.U. Five Zone (Non-UL) D8122 Derived Channel S.T.U. Five Zone (UL) Installation/Configuration Notes D8125MUX Multiplex Bus Interface Compatible Products D8125 POPEX Point Expander Keypads D1260 Series Keypads (D1260, D1260W, D1260R, D8128D OctoPOPIT Eight Point Expander D1260BLK, D1260B) D8129 Octo-relay Module D720 Series Keypads (D720, D720W, D720R, D720B) D9127 Series POPIT Modules D1255 Series Keypads (D1255, D1255W, D1255R, D9131A Printer and Parallel Interface Module D1255B, D1255RB) D9210BLC Access Control Interface Module D1256 and D1256RB Fire Keypads DS7432 Eight-input Remote Module D1257 and D1257RB Remote Fire Alarm Annunciators DS7457i Series Single Zone Multiplex Input Modules D279A Independent Zone Control DS7460i Two-input Module Detectors OD850 Series Outdoor TriTech Detectors DS7461i Single-input Multiplex Module MX250 Series Smoke Detectors DS7465i Input and Output Module MX775i Addressable PIR Detector DX4010i RS-232 Serial Interface Module MX794i Long Range Multiplex PIR Detector DX4020 Network Interface Module MX934i Addressable PIR Detector Peripheral Hard- rvm4c Remote Video Module MX938i Addressable PIR Detector ware ZX776Z PIR Detector Programming D5200 Series Programmers ZX794Z Long Range PIR Detector RPS or RPS-Lite Remote Programming Software ZX835 TriTech Microwave/PIR Detector Readers ARD-R10 iCLASS Mullion Reader ZX935Z PIR Detector ARD-R40 iCLASS Switchplate Reader ZX938Z PIR Detector ARD-RK40-09 iCLASS PIN Reader ZX970 PIR/Microwave Detector ARD-VSMART iCLASS Reader Bosch conventional detectors include Blue Line, seis- D8201/W Series Low-profile Readers mic, PIR, TriTech PIR Microwave, photoelectric, and D8203/W Series Mullion Proximity Readers heat, and smoke. D8223 Prox Pro Reader Enclosures D8103 Universal Enclosure D8224 Mullion Reader D8108A Attack-Resistant Enclosure D8224-SP Switch Plate Reader D8109 Fire Enclosure D8225 Mini Mullion Reader D8227 Insert Card Reader www.boschsecurity.com 4 | D7412G Control Panel Technical Specifications Keypads D1260 Series Keypads (D1260, D1260W, D1260R, D1260BLK, D1260B) Communications D8301/W Series Low-profile Proximity Readers SDI Bus A (+): 9 VDC D8302 Vandal-resistant Reader 4572 m (15,000 ft) D8303/W Series Mullion Proximity Readers SDI Bus B (-): 9 VDC D8304/W Series Extended Range Proximity Readers 4572 m (15,000 ft) WP644 Series Waterproof Pass-through Readers Telephone Connection: Two TelCo lines • SAFECOM Radio SC2104 Series Slave Communicators D928 Dual Phone Line module • Communicators required for 2 phone lines SC3100 Series Data Transfer Radio Communicators Environmental Considerations SC4000 Series Full Data Transfer Radio Communicator Relative Humidity: 5% to 85% at +30°C (+86°F), non-con- Wireless Prod- D8125INV Wireless Interface densing ucts Temperature (Operating): 0°C to +50°C (+32°F to +122°F) FA113 Keychain Remote Control FA116 Executive Programmer Number of… FA202 Wireless Smoke Detector and Transmitter Areas: 8 FA203S Necklace Pendant Transmitter (Single-button) Card Readers (Doors): 2 FA203D Necklace Pendant Transmitter (Double-but- Credentials (Tokens): 396 ton) Custom Functions: 4 FA204 Necklace Pendant Transmitter Events: Store up to 1,000 FA205S Belt Clip/Loop Transmitter (Single-button) Hardware Addresses: 75 FA205D Belt Clip/Loop Transmitter (Double-button) Parallel Printers: 1 FA206DS PIR Transmitter Passcode Users: 99, plus 1 service passcode FA206i PIR Transmitter Points: 75 (8 on-board, up to 67 off-board) FA209 Billtrap Transmitter Programmable Relay Outputs: 67 FA210 Universal Transmitter (Off-white) FA210-BN Universal Transmitter (Brown) RF Points: 67 FA210W Universal Wide Gap Transmitter (Off-white) SKEDs: 40 FA210W-BN Universal Wide Gap Transmitter (Brown) Power Requirements FA216L Low Temperature Transmitter Current Draw (Minimum): 200 mA FA216H High Temperature Transmitter Current Draw (Maximum): 500 mA FA223S Water-resistant Pendant (White Single-button) Output (Alarm): 2 A at 12 VDC FA223D Water-resistant Pendant (Black Double-but- ton) Output (Auxiliary, Continuous Pow- 1.4 A at 10.2 VDC to 13.9 VDC er, and Switched Auxiliary com- FA250 High-power Universal Transmitter bined): FA400 Remote Receiver Voltage (Operating): 12 VDC FA404R Transmitter Receiver Voltage (AC): 16.5 VAC 40 VA plug-in transformer FA416R Transmitter Receiver (D1640) FA570 High Power Indoor Repeater Voltage (DC): Up to 2 12 VDC, 7 Ah sealed lead • FA575 High Power Indoor/Outdoor Repeater acid rechargeable batteries Up to 2 12 VDC, 18 Ah sealed • lead acid rechargeable batteries Parts Included D7412G Components Quantity D7412G Board 1 Mounting Skirt 1 Faceplate with D7412G Label 1 D7412G Control Panel | 5 D7412G Kit Ordering Information Kits Components D7412G-A D7412G-B D7412G-C D7412G-D D7412G Board1 11 1 D1640 Transformer 11 11 D8103 Enclosure with D101 Lock and Key Set1 D8108A Attack-Resistant Enclosure with D101 1 Lock and Key Set D8109 Fire Enclosure with D101F Lock and 1 Key Set D6103 Enclosure with D101 Lock and Key Set1 D122 Dual Battery Harness 1 D928 Dual Phone Line Switcher 1 D161 2.1 m (7 ft) Dual Modular Phone Cords 2 Ordering Information Ordering Information D7412G Control Panel D7412G D1218 Battery (12 V, 18 Ah) D1218 Includes one printed circuit board (PCB). A 12 V sealed lead‑acid battery for standby and auxiliary power with two bolt‑fastened termi- D7412G Attack-Resistant Kit D7412G-A nals. Includes hardware for attaching battery Includes one PCB, one D8108A Attack-Resist- leads or spade connectors ant Enclosure, and one D1640 Transformer. D1224 Battery (12 V, 26‑28 Ah) D1224 D7412G Fire and Burglar Kit D7412G-B A 12 V sealed lead‑acid battery for standby and Includes one PCB, one D8109 Fire Enclosure, auxiliary power with two bolt‑fastened termi- one D928 Dual Phone Line Switcher, and two nals. Includes hardware for attaching battery D161 Dual Modular Phone Cords. leads or spade connectors. D7412G Commercial Burglar Kit D7412G-C D1238 Battery (12 V, 38 Ah) D1238 Includes one PCB, one D8103 Enclosure, and A 12 V sealed lead-acid battery for standby and one D1640 Transformer. auxiliary power with two bolt‑fastened termi- D7412G Commercial Burglar Kit D7412G-D nals. Includes hardware for attaching battery Includes one PCB, one D6103 Enclosure, and leads or spade connectors. one D1640 Transformer. D1640 Transformer D1640 Accessories D8103 Enclosure D8103 ICP‑EZTS Dual Tamper Switch ICP-EZTS D8108A Attack Resistant Enclosure D8108A Combination tamper switch with a wire loop for Grey steel enclosure measuring 41 cm x 41 cm additional tamper outputs. x 9 cm (16 in. x 16 in. x 3.5 in.). UL Listed. D101 Lock and Key Set D101 Includes lock and key set. Requires the D2402 Mounting Plate. D122 Dual Battery Harness D122 Harness with circuit breaker. Connects two D8109 Fire Enclosure D8109 batteries to a compatible control panel. Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9 cm (16 in. x 16 in. x 3.5 in). UL D122L Dual Battery Harness with Long D122L Listed. Includes a lock and key set. Leads Color-coded harness with circuit breaker and D9002‑5 Mounting Skirt D9002-5 leads measuring 89 cm (35 in.). Connects 12 V D136 Plug‑In Relay D136 batteries to compatible control panels. Maximum rating is 1 A at 24 VDC or 2 A at D126 Standby Battery (12 V, 7 Ah) D126 12 VDC. Available individually (D136) or in a Sealed lead‑acid standby and auxiliary re- package of 25 (D136‑25). chargeable power supply. D928 Dual Phone Line Switcher D928 D137 Mounting Bracket D137 Allows the control panel to operate over and Used to mount accessory modules in D8103, supervise two separate phone lines. Only one D8108A, and D8109 enclosures. D162 phone cord is supplied. Two additional D161 or D162 phone cords are required. D138 Mounting Bracket, Right Angle D138 Used to mount accessory modules in D8103, D8108A, and D8109 enclosures. www.boschsecurity.com 6 | D7412G Control Panel Ordering Information Software Options RPS Kit (LPT) D5500C-LPT Account management and control panel-pro- gramming software with LPT connection. RPS Kit (USB) D5500C-USB Account management and control panel-pro- gramming software with USB connection. Americas: Europe, Middle East, Africa: Asia-Pacific: Represented by Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Systems 130 Perinton Parkway P.O. Box 80002 11 Bishan Street 21 Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943 Phone: +1 800 289 0096 Phone: + 31 40 2577 284 Phone: +65 6258 5511 Fax: +1 585 223 9180 Fax: +31 40 2577 330 Fax: +65 6571 2698 security.sales@us.bosch.com emea.securitysystems@bosch.com apr.securitysystems@bosch.com www.boschsecurity.us www.boschsecurity.com www.boschsecurity.com © Bosch Security Systems Inc. 2010 | Data subject to change without notice T1659310475 | Cur: en-US, V9, 2 Jul 2010

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the D7412G?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products