ARCOM ACEpc

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number ACEpc
Manufacturer ARCOM
Category Base Boards (Carrier Boards)
Price Request Quote
Lead Time Request Quote

Description

Arcom’s ACEpc is a full-function PC-compatible platform for embedded control. I/O expansion is realized through PC/104 bus expansion sites, with non-dedicated break-outs

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Industrial Trading is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need an ACEpc? We can help you find it at a competitive price!

Features

  • ?16bit and 8bit PC/104 bus support
  • ?188EB, 386EX, SBC104, Elan-104 processor boards.
  • ?RS232 COMMS ports with PC/AT compatible 9way connectors
  • ?Terminal breakouts for up to 128 I/O lines
  • ?Up to 8 PC104 I/O modules can be installed
  • Field powered at 24VDC nominal

Datasheet

Download "Arcom-ACEpc-Baseboard-datasheet1-2110546297.pdf" (207 KiB)

Extracted Text

2192-09728-000-000 J570 ACEpc BASEBOARD PN Number: PN ACEpc BASEBOARD Introduction The ACEpc baseboard is a platform for using Arcom processor boards together with AIM 104 I/O modules. ACEpc Baseboard key features are: � Field powered at 24VDC nominal � Terminal breakouts for up to 128 I/O lines � 16bit and 8bit PC/104 bus support � RS232 COMMS ports with PC/AT compatible 9way connectors � 188EB, 386EX, SBC104, Elan-104 processor boards. � Up to 8 PC104 I/O modules can be installed Power Input Power Input The standard power supply for ACEpc is 18watts fully isolated which is capable of supporting up to 5 PC104 I/O modules. Other options available are: - 15watts non-isolated (up to 4 PC104 I/O modules) 30 watts isolated (up to 8 PC104 O/I modules) The input power can be within the range of 12VDC. To 30VDC. Over voltage protection and reverse protection are by electronic resetable fuse with a shunt Zener limiter. On-board supply regulators offer 5VDC (logic) and –12VDC for RS232 COMMS. Power is shared between the logic supply and the COMMS supply up to the maximum. The maximum taken by COMMS is 2.5W, which is sufficient for up to four Arcom AIM104-SER4C serial boards (giving 16 RS232 PORTS). Non-isolated power supplies are referenced to the field power supply although the OV common is separate from the chassis ground. APCpc Baseboard includes the facility for a Ground strap to OV if this is required for safety or shielding. (See diagram). To connect GND to the system, either use the stud on the case, or wire to the Power Input GND terminal. Use a wire link between the on-board screw terminals OV and GND to guard against floating OV. GND X -ve Regulated POWER +ve Power INPUT 0V X GND output GND terminals connect to board gnd-plane Page 1 J570 ACEpc BASEBOARD 2192-09728-000-000 AIM104 Modules The ACEpc Baseboard has two sites for AIM104 I/O modules, which support a wide range of I/O functions with on board signal conditioning. (See Assembly Drawing on page 4). Using the mounting kits supplied, AIM104 modules can be plugged into either Site and stacked to a maximum of four high (with the high profile cover). External connections are then made through ribbon cable headers translated to screw terminals on the Baseboard. I/O Connection AIM104-I/O modules using IDC headers for signal connection have I/O arranged in groups of up to eight signals with two supply references. These 10way groupings can be split out of a multiway ribbon cable for selective use in a system based on the APCpc Baseboard. External wiring can then be made to screw terminal ports with a generic pin designation : EXTERNAL PIN ASSIGNMENTS Pin numbers follow the ribbon cable wire number. PIN SIG SIG PIN 1 3 5 7 9 1 REFa IO0 2 3 IO1 IO2 4 5 IO3 IO4 6 7 IO5 IO6 8 9 IO7 REFb 10 2 4 6 8 10 AIM104 modules often include several groups of 10way I/O. By splitting the ribbon cable, only the groups which are required are terminated and maximum use can be made of the screw terminal break-out connectors on the Apex Baseboard. The diagram on the page 4 shows the general assembly of a system. Linking Information There are two sites on the ACEpc motherboard where it is possible to remove the EMC filtering components from the I/O connection circuit by simply removing the links. This provision is to enable PC104 modules that are likely to be adversely effected by the addition of another set of filters in the line, such as Arcom’s Motion1 board. See Assembly drawing on page 4 for more detail. Accessories and Options General options for the baseboard product are: � 188EB, 386EX, SBC104, Elan-104 processor boards. � Low profile cover (4 AIM modules max.) or High cover (8 AIM modules max.) � Panel mounting plates or DIN rail mounting feet. � ACE-TERM pack consisting of 8 connectors to mate up with the I/O sockets fitted to the ACEpc. The breakout details are as described above. � ACE-CAB50 50way IDC to 5 10 way IDC (10 ways supplied loose) to enable interconnection between the AIM104 modules and the motherboard. A Ac cc ce es ss so or ry y p pr ro od du uc ct ts s: : � COMMS breakout panel for AIM104-SER4C (not avaliable if using the Elan processor) � SBC104 VGA end plate option The COMMS breakout panel fits in place of the standard end panel and supports four additional PC/AT style COM connectors. RX/TX activity for each channel is indicated by LED�s. This panel is Page 2 2192-09728-000-000 J570 ACEpc BASEBOARD designed to plug directly to an AIM module in Site A, thus minimising the internal wiring. The SBCVGA end plate option gives breakout for VGA, LPT1 and Ethernet connectors. Development Support Arcom offers development support for all combinations of the ACEpc in the form of Target Development kits for the 188EB and the 386EX Target processors and ROM-DOS, Remote disk development, and flash filing system available for the SBC104 and the Elan104 processor types, Target software can be developed and debugged on a host PC using Arcoms SourceVIEW development tools. Other software can be developed on a host PC and downloaded to flash via a serial link for the SBC104 and the Elan104. Specification � Power input 24VDC nominal (12VDC to 32VDC) non-isolated � Maximum load 15W, 5V 3A , +12V 80mA, -12V 80mA (power sharing) � Temperature range -20�C to +70�C ambient � Dimensions 185mm x 275mm approx. without cables/connectors. � Mounted in a steel chassis. Giving overall dimensions of approximatly 320mm x 200mm. � End plate opposite to processor is fitted with cut outs for 9, 25 and 37 way �D� types for customer specific breakout (filtered �D� connectors are reccomended for use on this panel to maintain EMC) � Heights (incl. mtg. brackets) : Low profile panel mount 94mm. : Low profile DIN rail mount 119mm. : High profile panel mount 120mm. : High profile DIN rail mount 145mm. Page 3 J570 ACEpc BASEBOARD 2192-09728-000-000 Assembly Drawing End plate Shown with SBC104 fitted Filter links AIM 104 siteA AIM 104 siteB Power Supply End plate fitted with 9,25 and 37way "D" type cutouts End view showing high profile cover fitted 4 Pc104 modules stacked & Processor Mounted Uderneath Page 4 2192-09728-000-000 J570 ACEpc BASEBOARD Wall mounted details N No ot te e: There are a choice of wall mounting brackets (slotted, non slotted or a combination as shown) together with a din rail mounting option. Page 5 95 190 J570 ACEpc BASEBOARD 2192-09728-000-000 Drawing shows overall dimensions and mounting details. Both mounting options are shown. For the wall bracket option add 12 mm to the overall hight. For DIN rail mounting option add 30mm to allow for the bracket and DIN rail. Plan View 108 Dimensions shown are all in Milimeters Page 6 357 32 0 2192-09728-000-000 J570 ACEpc BASEBOARD Product Information Full information about other Arcom products is available via the F Fa ax x--o on n--D De em ma an nd d S Sy ys stte em m, (Telephone W We eb bS Si it te e w ww ww w. .a ar rc co om m. .c co o. .u uk k Numbers are listed below), or by contacting our in the UK at: or in the US at: w ww ww w. .a ar rc co om mc co on nt tr ro ol ls s. .c co om m U Us se ef fu ul l C Co on nt ta ac ct t I In nf fo or rm ma at ti io on n C Cu us st to om me er r S Su up pp po or rt t S Sa al le es s o or r f fo or r t th he e U US S: : E E- -m ma ai il l Tel: +44 (0)1223 412 428 Tel: +44 (0)1223 411 200 icpsales@arcomcontrols.com Fax: +44 (0)1223 403 409 Fax: +44 (0)1223 410 457 E-mail: support@arcom.co.uk E-mail sales@arcom.co.uk U Un ni it te ed d K Ki in ng gd do om m U Un ni it te ed d S St ta at te es s F Fr ra an nc ce e B Be el lg gi iu um m I It ta al ly y Arcom Control Systems Ltd Arcom Control Systems Inc Tel: 0800 90 84 06 Groen Nummer: Numero Verde: Clifton Road 13510 South Oak Street Fax: 0800 90 84 12 Tel: 0800 7 3192 Tel: 1677 90841 Cambridge CB1 7EA, UK Kansas City MO 64145 USA FoD: 0800 90 23 80 Fax: 0800 7 3191 Fax: 1677 80841 Tel: 01223 411 200 Tel: 816 941 7025 FoD: 1678 73600 Fax: 01223 410 457 Fax: 816 941 0343 G Ge er rm ma an ny y N Ne et th he er rl la an nd ds s FoD: 01223 240 600 FoD: 800 747 1097 Kostenlose Infoline: Gratis 0800 Nummer: Tel: 0130 824 511 Tel: 0800 0221136 Fax: 0130 824 512 Fax: 0800 022114 FoD: 0130 860 449 Whilst Arcom�s sales team is always available to assist you in making your decision, the final choice of boards or systems is solely and wholly the responsibility of the buyer. Arcom�s entire liability in respect of the boards or systems is as set out in Arcom�s standard terms and conditions of sale. If you intend to write your own low level software, you can start with the source code on the disk which is supplied. This is example code only to illustrate use on Arcom�s products. It has not been commercially tested. No warranty is made in respect of this code and Arcom shall incur no liability whatsoever or howsoever arising from any use made of the code. ' 1998 Arcom Control Systems Ltd Arcom Control Systems is a subsidiary of Fairey Group Plc. All trademarks recognised. Arcom Control Systems Ltd operate a company-wide quality management system which has been certified by the British Standards Institution (BSI) as compliant with ISO9001:1994 Page 7 J570 ACEpc BASEBOARD 2192-09728-000-000 Page 8

Related Products

ARCOM
ARCOM CONTROL SYSTEMS SCT-AIM104 Carrier Board with Power Converter and 4x...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Industrial Trading are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Industrial Trading is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.043 seconds.