ALLEN-BRADLEY 1756-L61S

Image of ALLEN-BRADLEY 1756-L61S

Description

Allen-Bradley 1756-L61S GuardLogix safety processor with 2 MB of memory

Part Number

1756-L61S

Price

Request Quote

Manufacturer

ALLEN-BRADLEY

Lead Time

Request Quote

Category

Programmable Automation Controllers

Specifications

Analog I/O, max

4000

Chassis

1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17

Current draw @ 24V DC

14 mA

Current draw @ 5.1V DC

1200 mA

Digital I/O, max

128,000

Enclosure type rating

None (open-style)

I/O memory

478 KB

Isolation voltage

30V (continuous), Basic Insulation Type, RS-232 to system

Module location

Chassis-based, any slot

North American temperature code

T4A

Optional flash memory(1)

64 MB (cat. no. 1784-CF64), 128 MB (cat. no. 1784-CF128)

Power dissipation

3.5 W

Power supply, redundant

1756-PA75R, 1756-PB75R, 1756-PSCA2

Power supply, standard

1756-PA72/C, 1756-PA75/B, 1756-PB72/C, 1756-PB75/B, 1756-PC75/B, 1756-PH75/B

Replacement battery

1756-BA2

Safety memory

1 MB

Serial cables

1756-CP3 or 1747-CP3, right angle connector to controller, straight to serial port, 3 m (9.84 ft)

Slot width

1

Thermal dissipation

11.9 BTU/hr

Total I/O, max

128,000

Type

tested at 720V DC for 60 s

User memory

2 MB

Weight, approx.

0.32 kg(0.70 lb)

Wire category

2 - on communication ports(2)

Features

Datasheet

pdf file

Allen Bradley=1756-series=datashee-1772221120t.pdf

1721 KiB

Extracted Text

Technical Data 1756 ControlLogix Controllers Specifications ControlLogix Controller Catalog Numbers 1756-L61, 1756-L62, 1756-L63, 1756-L64, 1756-L65, 1756-L72, 1756-L73, 1756-L74, 1756-L75 GuardLogix Controller Catalog Numbers 1756-L61S, 1756-L62S, 1756-L63S, 1756-LSP ControlLogix-XT Controller Catalog Number 1756-L63XT ControlLogix Redundancy Catalog Numbers 1756-RM, 1756-RMXT Memory Card Catalog Numbers 1784-CF64, 1784-CF128, 1784-SD1, 1784-SD2 Topic Page 1756 ControlLogix Controllers 3 1756 GuardLogix Controllers 9 1756 ControlLogix-XT Controllers 12 Controller Memory Use 14 Controller Compatibility 14 ControlLogix Redundancy 18 ControlLogix Connections 21 ControlLogix Controller Accessories 23 1756 ControlLogix Controllers Specifications Solid state equipment has operational characteristics differing from those of Important User Information electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. IMPORTANT Identifies information that is critical for successful application and understanding of the product. Rockwell Automation, Rockwell Software, Allen-Bradley, ArmorBlock, ArmorBlock Guard I/O, ArmorBlock MaXum, ArmorPoint, Compact I/O, CompactBlock I/O, CompactBlock Guard I/O, CompactLogix, ControlLogix, ControlLogix-XT, Data Highway Plus, DH+, DriveLogix, FactoryTalk, FLEX Ex, FLEX I/O, FLEX I/O-XT, FlexLogix, Guard I/O, GuardLogix, InView, MicroLogix, On-Machine, PanelView, PanelView e, PanelView Plus, PLC-2, PLC-3, PLC-5, POINT I/O, POINT Guard I/O, PowerFlex, RSLinx, RSLinx Enterprise, RSLogix 5000, SCANport, SLC, SoftLogix, SynchLink, TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. 2 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications The ControlLogix controller provides a scalable controller solution that is 1756 ControlLogix capable of addressing a large amount of I/O points. The ControlLogix controller Controllers can be placed into any slot of a ControlLogix I/O chassis and multiple controllers can be installed in the same chassis. ControlLogix controllers can monitor and control I/O across the ControlLogix backplane, as well as over network links. To provide communication for a ControlLogix controller, install the appropriate communication interface module into the chassis. Features - Standard ControlLogix Controllers Feature 1756-L61, 1756-L62, 1756-L63, 1756-L64, 1756-L72, 1756-L73, 1756-L74, 1756-L75 1756-L65 Controller tasks  32 tasks  100 programs/task  Event tasks: all event triggers Built-in communication ports 1 port RS-232 serial 1 port USB Communication options  EtherNet/IP  ControlNet  DeviceNet  Data Highway Plus  Remote I/O  SynchLink  Third-party process and device networks Serial port communication  ASCII —  DF1 full/half-duplex  DF1 radio modem  DH-485  Modbus via logic Controller connections supported, max 250 500 Network connections, per network module  100 ControlNet (1756-CN2/A)  40 ControlNet (1756-CNB)  256 EtherNet/IP; 128 TCP (1756-EN2x)  128 EtherNet/IP; 64 TCP (1756-ENBT) Controller redundancy Full support Integrated motion  SERCOS interface  Analog options (encoder input, LDT input, SSI input) Programming languages  Relay ladder  Structured text  Function block  SFC Scan time for a project loaded in a 1756-L64 or 1756-L65 controller may be slower than for IMPORTANT the same project loaded in one of the other 1756-L6x controllers. See the Logix5000 Controllers Instruction Execution Time and Memory Use Reference Manual, publication 1756-RM087, for instruction execution times. Publication 1756-TD001D-EN-E - May 2011 3 1756 ControlLogix Controllers Specifications Technical Specifications - 1756-L6x ControlLogix Controllers Attribute 1756-L61 1756-L62 1756-L63 1756-L64 1756-L65 User memory 2 MB 4 MB 8 MB 16 MB 32 MB I/O memory 478 KB Optional nonvolatile memory storage 64 MB (cat. no. 1784-CF64) 128 MB (cat. no. 1784-CF128) Digital I/O, max 128,000 Analog I/O, max 4000 Total I/O, max 128,000 (1) Series A: 1756-BA1, Series A: 1756-BA1, Series A: 1756-BA1, Replacement battery 1756-BATM, 1756-BATM, 1756-BATM, 1756-BATA 1756-BATA 1756-BATA Series B: 1756-BA2 Series B: 1756-BA2 Series B: 1756-BA2 1756-BA2 Current draw @ 5.1V DC 1200 mA Current draw @ 24V DC 14 mA Power dissipation 3.5 W Thermal dissipation 11.9 BTU/hr Isolation voltage 30V (continuous), basic insulation type, RS-232 to system Controllers tested to withstand 720V DC for 60 s Serial cables 1756-CP3 or 1747-CP3, right angle connector to controller, straight to serial port, 3 m (9.84 ft) Weight, approx. Series A: 0.32 kg Series A: 0.32 kg Series A: 0.32 kg Series A: 0.32 kg Series A: 0.32 kg Series B: 0.35 kg Series B: 0.35 kg Series B: 0.35 kg Series B: 0.35 kg Series B: 0.35 kg (Series A: 0.71 lb (Series A: 0.71 lb (Series A: 0.71 lb (Series A: 0.71 lb (Series A: 0.71 lb Series B: 0.78 lb) Series B: 0.78 lb) Series B: 0.78 lb) Series B: 0.78 lb) Series B: 0.78 lb) Slot width 1 Module location Chassis-based, any slot Chassis 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 Power supply, standard 1756-PA72/C, 1756-PA75/B, 1756-PB72/C, 1756-PB75/B, 1756-PC75/B, 1756-PH75/B Power supply, redundant 1756-PA75R, 1756-PB75R, 1756-PSCA2 (2) Wire category 2 - on communication ports North American temperature code T4A IEC temperature code T4 Enclosure type rating None (open-style) (1) For Australian Mining certification applications, only Series A and a 1756-BA1 battery can be used. For more information, contact your local distributor or sales office. (2) Use this conductor category information for planning conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. 4 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications Environmental Specifications - 1756-L6x ControlLogix Controllers Attribute 1756-L61, 1756-L62, 1756-L63, 1756-L64, 1756-L65 Temperature, operating 0…60 °C (32…140 °F) IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, storage -40…85 °C (-40…185 °F) IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity 5…95% noncondensing IEC 60068-2-30 (Test Db, Unpackaged Damp Heat) Vibration 2 g @ 10…500 Hz IEC 60068-2-6 (Test Fc, Operating) Shock, operating 30 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Shock, nonoperating 50 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Emissions Group 1, Class A CISPR 11 ESD immunity 6 kV contact discharges IEC 61000-4-2 8 kV air discharges Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz EFT/B immunity ±4 kV at 5 kHz on communication ports IEC 61000-4-4 Surge transient immunity ±2 kV line-earth (CM) on communication ports IEC 61000-4-5 Conducted RF immunity 10Vrms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz IEC 61000-4-6 Publication 1756-TD001D-EN-E - May 2011 5 1756 ControlLogix Controllers Specifications Certifications - 1756-L6x ControlLogix Controllers (1) 1756-L61, 1756-L62, 1756-L63, 1756-L64, 1756-L65 Certification c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. CSA CSA Certified Process Control Equipment. See CSA File LR54689C. CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations. See CSA File LR69960C. CE European Union 2004/108/EC EMC Directive, compliant with:  EN 61326-1; Meas./Control/Lab., Industrial Requirements  EN 61000-6-2; Industrial Immunity  EN 61000-6-4; Industrial Emissions  EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions Ex European Union 94/9/EC ATEX Directive, compliant with:  EN 60079-15; Potentially Explosive Atmospheres, Protection “n” (Zone 2)  EN60079-0; General Requirements  II 3 G Ex nA IIC T4 X Important: The 1756-L64 and 1756-L65 controllers do not have this certification. FM FM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations (2) Certified by TÜV: Capable of SIL2 Functional safety Important: This certification applies only to the 1756-L61, 1756-L62, and 1756-L63 controllers. (1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. (2) When used with specified firmware revisions. 6 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications Technical Specifications - 1756-L7x ControlLogix Controllers Attribute 1756-L72 1756-L73 1756-L74 1756-L75 User memory 4 MB 8 MB 16 MB 32 MB I/O memory 0.98 MB Optional nonvolatile memory storage 1 GB (cat. no. 1784-SD1) 2 GB (cat. no. 1784-SD2) Digital I/O, max 128,000 Analog I/O, max 4000 Total I/O, max 128,000 Energy storage module 1756-ESMCAP capacitor-based energy-storage module 1756-ESMNSE energy-storage module without stored energy 1756-ESMNRM energy-storage module that secures the controller by preventing the USB connection and Secure Digital card use Current draw @ 1.2V DC 5 mA Current draw @ 5.1V DC 800 mA Power dissipation 2.5 W Thermal dissipation 8.5 BTU/hr Isolation voltage 30V (continuous), basic insulation type, USB port-to-system Type tested at 500V AC for 60 s USB port USB 2.0, full speed (12 Mbps) USB cable Samtec cable, P/N RSP-199350 Weight, approx. 0.25 kg (0.55 lb) Slot width 1 Module location Chassis-based, any slot Chassis 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 Power supply, standard 1756-PA72/C, 1756-PA75/B, 1756-PB72/C, 1756-PB75/B, 1756-PC75/B, 1756-PH75/B Power supply, redundant 1756-PA75R, 1756-PB75R, 1756-PSCA2 (1) Wire category 3 - on USB port North American temperature code T5 IEC temperature code T5 Enclosure type rating None (open-style) (1) Use this conductor category information for planning conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Publication 1756-TD001D-EN-E - May 2011 7 1756 ControlLogix Controllers Specifications Environmental Specifications - 1756-L7x ControlLogix Controllers Attribute 1756-L72, 1756-L73, 1756-L74, 1756-L75 Temperature, operating 0…60 °C (32…140 °F) IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, storage -40…85 °C (-40…185 °F) IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity 5…95% noncondensing IEC 60068-2-30 (Test Db, Unpackaged Damp Heat) Vibration 2 g @ 10…500 Hz IEC 60068-2-6 (Test Fc, Operating) Shock, operating 30 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Shock, nonoperating 50 g (45 g with SD card installed) IEC 60068-2-27 (Test Ea, Unpackaged Shock) Emissions Group 1, Class A CISPR 11 ESD immunity 6 kV contact discharges IEC 61000-4-2 8 kV air discharges Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz Certifications - 1756-L7x ControlLogix Controllers (1) 1756-L72, 1756-L73, 1756-L74, 1756-L75 Certification c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. CE European Union 2004/108/EC EMC Directive, compliant with:  EN 61326-1; Meas./Control/Lab., Industrial Requirements  EN 61000-6-2; Industrial Immunity  EN 61000-6-4; Industrial Emissions  EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions Ex European Union 94/9/EC ATEX Directive, compliant with:  EN 60079-15; Potentially Explosive Atmospheres, Protection ’n’  EN 60079-0; General Requirements  II 3 G Ex nA IIC T5X (1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. 8 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications A GuardLogix controller is a ControlLogix controller that also provides safety 1756 GuardLogix control. The GuardLogix system is a dual controller solution—you must use a Controllers 1756-L6xS primary controller and a 1756-LSP safety partner to achieve SIL 3/CAT. 4. A major benefit of this system is that it’s still a single project, safety and standard together. The safety partner controller is a part of the system, is automatically configured, and requires no user setup. During development, safety and standard have the same rules, multiple programmers, online editing, and forcing are all allowed. Once the project is tested and ready for final validation, you set the Safety Task to a SIL 3 integrity level, which is then enforced by the GuardLogix controller. When safety memory is locked and protected, the safety logic can't be modified and all safety functions operate with SIL 3 integrity. On the standard side of the GuardLogix controller, all functions operate like a regular Logix controller. Thus online editing, forcing, and other activities are all allowed. With this level of integration, safety memory can be read by standard logic and external devices, like HMIs or other controllers, eliminating the need to condition safety memory for use elsewhere. The result is easy system-wide integration and the ability to display safety status on displays or marquees. Use Guard I/O modules for field device connectivity on Ethernet or DeviceNet networks, and for safety interlocking between GuardLogix controllers use Ethernet or ControlNet networks. Multiple GuardLogix controllers can share safety data for zone to zone interlocking, or a single GuardLogix controller can use remote distributed safety I/O between different cells/areas. In addition to the standard features of a ControlLogix controller, the GuardLogix controller has these safety-related features. Features - GuardLogix Controllers Feature 1756-L61S, 1756-L62S, 1756-L63S, 1756-LSP Safety communication options Standard and safety  EtherNet/IP  ControlNet  DeviceNet Network connections, per network module  100 ControlNet (1756-CN2/A)  40 ControlNet (1756-CNB)  256 EtherNet/IP; 128 TCP (1756-EN2x)  128 EtherNet/IP; 64 TCP (1756-ENBT) Controller redundancy Not supported Programming languages Relay ladder Publication 1756-TD001D-EN-E - May 2011 9 1756 ControlLogix Controllers Specifications Technical Specifications - 1756 GuardLogix Controllers Attribute 1756-L61S 1756-L62S 1756-L63S 1756-LSP User memory 2 MB 4 MB 8 MB — Safety memory 1 MB 1 MB 3.75 MB — I/O memory 478 KB — (1) 64 MB (cat. no. 1784-CF64) — Optional flash memory 128 MB (cat. no. 1784-CF128) Digital I/O, max 128,000 — Analog I/O, max 4000 — Total I/O, max 128,000 — Replacement battery 1756-BA2 Current draw @ 5.1V DC 1200 mA Current draw @ 24V DC 14 mA Power dissipation 3.5 W Thermal dissipation 11.9 BTU/hr Isolation voltage 30V (continuous), Basic Insulation Type, RS-232 to system Type tested at 720V DC for 60 s Serial cables 1756-CP3 or 1747-CP3, right angle connector to controller, straight to serial port, 3 m (9.84 ft) Weight, approx. 0.32 kg (0.70 lb) Slot width 1 Module location Chassis-based, any slot Chassis 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 Power supply, standard 1756-PA72/C, 1756-PA75/B, 1756-PB72/C, 1756-PB75/B, 1756-PC75/B, 1756-PH75/B Power supply, redundant 1756-PA75R, 1756-PB75R, 1756-PSCA2 (2) Wire category 2 - on communication ports North American temperature code T4A Enclosure type rating None (open-style) (1) The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card. (2) Use this conductor category information for planning conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. 10 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications Environmental Specifications - 1756 GuardLogix Controllers Attribute 1756-L61S, 1756-L62S, 1756-L63S, 1756-LSP Temperature, operating 0…60 °C (32…140 °F) IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, storage -40…85 °C (-40…185 °F) IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity 5…95% noncondensing IEC 60068-2-30 (Test Db, Unpackaged Damp Heat) Vibration 2 g @ 10…500 Hz IEC 60068-2-6 (Test Fc, Operating) Shock, operating 30 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Shock, nonoperating 50 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Emissions Group 1, Class A CISPR 11 ESD immunity 6kV contact discharges IEC 61000-4-2 8kV air discharges Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz EFT/B immunity ±4 kV at 5 kHz on communication ports IEC 61000-4-4 Surge transient immunity ±2 kV line-earth (CM) on communication ports IEC 61000-4-5 Conducted RF immunity 10Vrms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz IEC 61000-4-6 Certifications - 1756 GuardLogix Controllers (1) 1756-L61S, 1756-L62S, 1756-L63S, 1756-LSP Certification c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. CSA CSA Certified Process Control Equipment. See CSA File LR54689C. CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations. See CSA File LR69960C. CE European Union 2004/108/EC EMC Directive, compliant with:  EN 61000-6-4; Industrial Emissions  EN 61326-1; Meas./Control/Lab., Industrial Requirements  EN 61000-6-2; Industrial Immunity  EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions FM FM Approved Equipment for use in Class I, Division 2 Group A, B, C, D Hazardous Locations (2) Certified by TÜV: capable of SIL 3, according to IEC 61508; and PLe/Cat. 4 according to ISO 13849-1:2006. Functional Safety Certified by UL: capable of SIL 3, see UL File E256621. (1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. (2) When used with specified firmware revision. Publication 1756-TD001D-EN-E - May 2011 11 1756 ControlLogix Controllers Specifications The ControlLogix-XT controllers function in the same way as the traditional 1756 ControlLogix-XT ControlLogix controllers. The ControlLogix-XT products include control and Controllers communication system components that are conformally coated to extend product life in harsh, corrosive environments.  When used with FLEX I/O-XT products, the ControlLogix-XT system can withstand temperatures range from -20…70 C (-4…158 F).  When used independently, the ControlLogix-XT system can withstand temperature ranges from -25…70 C (-13…158 F). Technical Specifications - 1756-L63XT Controller Attribute 1756-L63XT User memory 8 MB I/O memory 478 KB Optional flash memory 64 MB (cat. no. 1784-CF64) 128 MB (cat. no. 1784-CF128) Digital I/O, max 128,000 Analog I/O, max 4000 Total I/O, max 128,000 Replacement battery 1756-BA2 Current draw @ 5.1V DC 1200 mA Current draw @ 24V DC 14 mA Power dissipation 3.5 W Thermal dissipation 11.9 BTU/hr Isolation voltage 30V (continuous), basic insulation type, RS-232 to system Type tested at 720V DC for 60 s Serial cables 1756-CP3 or 1747-CP3, right angle connector to controller, straight to serial port, 3 m (9.84 ft) Weight, approx. 0.35 kg (0.78 lb) Slot width 1 Module location Chassis-based, any slot Chassis 1756-A5XT, 1756-A7LXT Power supply, standard 1756-PBXT Power supply, redundant None (1) Wire category 2 - on communication ports North American temperature code T4A IEC temperature code T4 Enclosure type rating None (open-style) (1) Use this conductor category information for planning conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. 12 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications Environmental Specifications - 1756-L63XT and 1756-L73XT Controller Attribute 1756-L63XT Temperature, operating -25…70 °C (-13…158 °F) IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, storage -40…85 °C (-40…185 °F) IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity 5…95% noncondensing IEC 60068-2-30 (Test Db, Unpackaged Damp Heat) Vibration 2 g @ 10…500 Hz IEC 60068-2-6 (Test Fc, Operating) Shock, operating 30 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Shock, nonoperating 50 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Emissions Group 1, Class A CISPR 11 ESD immunity 6 kV contact discharges IEC 61000-4-2 8 kV air discharges Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz EFT/B immunity ±4 kV at 5 kHz on communication ports IEC 61000-4-4 Surge transient immunity ±2 kV line-earth (CM) on communication ports IEC 61000-4-5 Conducted RF immunity 10Vrms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz IEC 61000-4-6 Certifications - 1756-L63XT Controller (1) 1756-L63XT Certification c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. CE European Union 2004/108/EC EMC Directive, compliant with:  EN 61000-6-4; Industrial Emissions  EN 61326-1; Meas./Control/Lab., Industrial Requirements  EN 61000-6-2; Industrial Immunity  EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions Ex European Union 94/9/EC ATEX Directive, compliant with:  EN 60079-15; Potentially Explosive Atmospheres, Protection ’n’  EN 60079-0; General Requirements  II 3 G Ex nA IIC T4 X (2) Certified by TÜV: Capable of SIL 2 Functional safety (1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. (2) When used with specified firmware revisions. Publication 1756-TD001D-EN-E - May 2011 13 1756 ControlLogix Controllers Specifications The following equations provide a rough memory estimate. Controller Memory Use Controller tasks _____ x 4000 = _____ bytes (minimum 1 task) Digital I/O points _____ x 400 = _____ bytes Analog I/O points _____ x 2600 = _____ bytes (1) _____ x 7400 = _____ bytes DeviceNet modules (2) _____ x 2000 = _____ bytes Other communication modules Motion axis _____ x 8000 = _____ bytes FactoryTalk alarm instruction _____ x 1000 = _____ bytes (per alarm) FactoryTalk subscriber _____ x 10000 = _____ bytes (1) The first DeviceNet module is 7400 bytes. Additional DeviceNet modules are 5800 bytes each. (2) Count all the communication modules in the system, not just those in the local chassis. This includes device connection modules, adapter modules, and ports on PanelView terminals. For redundant controller systems, double the memory estimate you calculate. For example, if you estimate you need 2 MB of memory, select a controller with 4 MB of memory. Reserve 20…30% of the controller memory to accommodate growth. Control Distributed I/O Modules Controller Compatibility The controller can control these distributed I/O modules via the I/O Configuration tree in RSLogix 5000 programming software. I/O Modules EtherNet/IP ControlNet DeviceNet Remote I/O Chassis-based I/O 1746 SLC I/O No No No Yes 1756 ControlLogix I/O Yes Yes No No 1769 Compact I/O No No Yes No 1771 Universal I/O No Yes No Yes In-cabinet I/O 1734 POINT I/O Yes Yes Yes No 1734D POINTBlock I/O No No Yes No 1790, 1790D, 1790P CompactBlock LDX I/O No No Yes No 1791D, 1791P, 1791R CompactBlock I/O No No Yes No 1794 FLEX I/O Yes Yes Yes Yes 1797 FLEX Ex I/O No Yes No No On-machine I/O 1732 ArmorBlock I/O Yes No Yes No 1738 ArmorPoint I/O Yes Yes Yes No 1792D ArmorBlock MaXum I/O No No Yes No 1799 Embedded I/O No No Yes No 14 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications Control Safety I/O Modules The GuardLogix controller can control these safety I/O modules in a safety system. I/O Modules EtherNet/IP ControlNet DeviceNet In-cabinet I/O 1791DS CompactBlock Guard I/O No No Yes 1791ES CompactBlock Guard I/O Yes No No 1734 POINT Guard I/O Yes No No On-machine I/O 1732DS ArmorBlock Guard I/O No No Yes Communicate with Display Devices The controller can communicate with these display devices. Display Devices EtherNet/IP ControlNet DeviceNet DH+ Remote I/O RS-232 (DF1) DH-485 Industrial Computers Rockwell Automation industrial Yes Yes Yes Yes Yes Yes Yes (1) computers (all) Graphic Terminals PanelView Plus and PanelView CE Yes Yes Yes Yes Yes Yes Yes terminals PanelView Standard terminals Yes Yes Yes Yes Yes Yes Yes PanelView ’e’ terminals No Yes No Yes Yes No No Message Displays InView message displays Yes Yes Yes Yes Yes Yes Yes (1) Includes Rockwell Automation integrated display rotating media (HDD) and solid state (SSD) computers, Rockwell Automation non-display computers, and Rockwell Automation integrated display computers with keypad. Publication 1756-TD001D-EN-E - May 2011 15 1756 ControlLogix Controllers Specifications Communicate with Other Controllers The controller can communicate with these programmable controllers. (1) Controller EtherNet/IP ControlNet DeviceNet DH+ RS-232 (DF1) DH-485 1756 ControlLogix Yes Yes Yes Yes Yes Yes 1756 GuardLogix 1768, 1769 CompactLogix Yes Yes Yes No Yes Yes 1768 Compact GuardLogix 1789 SoftLogix5800 Yes Yes Yes No Yes No 1794 FlexLogix Yes Yes Yes No Yes Yes PowerFlex with DriveLogix Yes Yes Yes No Yes Yes (2) (3) (4) 1785 PLC-5 Yes Yes Yes — Yes Yes (5) (4) 1747 SLC Yes Yes Yes Yes Yes Yes (4) 1761 MicroLogix Yes No No Yes Yes Yes (4) 1762 MicroLogix Yes No No Yes Yes Yes (4) 1763 MicroLogix Yes No No Yes Yes Yes (4) 1764 MicroLogix Yes No No Yes Yes Yes 1772 PLC-2 — — — Yes Yes — 1775 PLC-3 — — — Yes Yes — 5250 PLC-5/250 — — No Yes Yes — (1) The 1756-DH485 module supports full DH-485 functionality. (2) The Ethernet PLC-5 controller must be series C, firmware revision N.1 or later; series D, firmware revision E.1 or later; or series E, firmware revision D.1 or later. (3) The 1785-ENET Ethernet communication interface module must be series A, firmware revision D or later. (4) The PLC-5, SLC, and MicroLogix processors appear as I/O points to the Logix controller. Use the appropriate DeviceNet interface for the controller. (5) Use a 1747-L55x controller with OS501 or later. 16 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications Communicate with Other Communication Devices The controller can communicate with these communication devices. Communication Device EtherNet/IP ControlNet DeviceNet DH+ Linking device (ControlLogix controllers only) 1788-EN2DN 1788-CN2DN 1788-EN2DN — 1788-CN2FF 1788-CN2DN PCMCIA card — 1784-PCC 1784-PCD 1784-PCMK PCI card — 1784-PCIC 1784-PCID — 1784-PCICS 1784-PCIDS 1784-CPCIDS Drives SCANport module — 1203-FM1 — — (1) 1203-FB1 (2) Communication module — 1770-KFD — 1203-CN 1770-KFG 1770-KFC15 1770-KFCD15 1747-KFC15 Communication card — 1784-PKTCS 1784-PKTX — 1784-KTCS 1784-PKTXD 1784-KTCX15 USB communication device — 1784-U2CN 1784-U2DN 1784-U2DHP (1) Use a CIP generic MSG instruction to communicate with the 1203-FM1 SCANport module on a DIN rail that is remote to the controller. The remote DIN rail also requires a 1794-ACN15 or 1794-ACNR15 ControlNet adapter module. (2) Use the generic module configuration to configure the 1203-CN1 module and a CIP generic MSG instruction to communicate with the module. Publication 1756-TD001D-EN-E - May 2011 17 1756 ControlLogix Controllers Specifications The ControlLogix controller supports controller redundancy. In a redundant ControlLogix Redundancy controller system, you need these components:  Two 1756 chassis, each with the same of the following: – Number of slots – Modules in the same slots – Redundancy firmware revisions in each module – Two additional ControlNet nodes outside the redundant chassis pair if the application uses ControlNet networks  One 1756-RM or 1756-RMXT module per chassis that is connected by a 1756-RMCx cable  One or two 1756-L6x or 1756-L7x controllers in each chassis  Up to seven enhanced ControlNet communication modules, that is, 1756-CN2/B, 1756-CN2R/B, 1756-CN2RXT modules  Up to seven enhanced EtherNet/IP communication modules, that is, 1756-EN2T, 1756-EN2TR, or 1756-EN2TXT modules Technical Specifications - 1756 Redundancy Modules Attribute 1756-RM 1756-RMXT Current draw @ 1.2V DC 4 mA Current draw @ 5.1V DC 1.2 A Current draw @ 24V DC 120 mA Power dissipation 9.0 W Thermal dissipation 31 BTU/hr Connector cables 1756-RMC1, 1 m (3.28 ft) 1756-RMC3, 3 m (9.84 ft) 1756-RMC10, 10 m (32.81 ft) Slot width 1 slot Module location Chassis-based, any slot Chassis 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 1756-A4LXT, 1756-A5LXT, 1756-A7LXT Power supply, standard 1756-PA72/C, 1756-PA75/B, 1756-PB72/C, 1756-PB75/B, 1756-PBXT 1756-PC75/B, 1756-PH75/B Power supply, redundant 1756-PA75R, 1756-PB75R, 1756-PSCA2 None North American temperature code T4 IEC temperature code T4 Enclosure type None (open-style) Weight 0.293 kg (0.64 lb) Mounting ControlLogix-XT chassis, single-slot module 18 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications Environmental Specifications - 1756 Redundancy Module Attribute 1756-RM 1756-RMXT Temperature, operating 0…60 °C (32…140 °F) -25…70 °C (-13…158 °F) IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, storage -40…85 °C (-40…185 °F) IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity 5…95% noncondensing IEC 60068-2-30 (Test Db, Unpackaged Damp Heat) Vibration 2 g @ 10…500 Hz IEC 60068-2-6 (Test Fc, Operating) Shock, operating 30 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Shock, nonoperating 50 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Emissions Group 1, Class A CISPR 11 ESD immunity 6 kV contact discharges IEC 61000-4-2 8 kV air discharges Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz Publication 1756-TD001D-EN-E - May 2011 19 1756 ControlLogix Controllers Specifications Certifications - 1756 Redundancy Module (1) 1756-RM 1756-RMXT Certification CSA CSA Certified Process Control Equipment. See CSA File — LR54689C. CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations. See CSA File LR69960C. CE European Union 2004/108/IEC EMC Directive, compliant with:  EN 61326-1; Meas./Control/Lab., Industrial Requirements  EN 61000-6-2; Industrial Immunity  EN 61000-6-4; Industrial Emissions  EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions c-UL-us UL Listed Industrial Control Equipment, certified for U.S. and Canada. See UL file E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. Ex European Union 94/9/EC ATEX Directive, compliant with:  EN 60079-15; Potentially Explosive Atmospheres, Protection “n”  EN 60079-0; General Requirements  II 3 G Ex nA IIC T4 X FM FM Approved Equipment for use in Class I Division 2 — Group A,B,C,D Hazardous Locations (2) Certified by TÜV: Capable of SIL 2 Functional safety (1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. (2) When used with specified firmware revisions. 20 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications A ControlLogix system uses connections to establish communication links ControlLogix Connections between devices. The types of connections include the following:  Controller-to-local I/O modules or local communication modules  Controller-to-remote I/O or remote communication modules  Controller-to-remote I/O (rack-optimized) modules  Produced and consumed tags  Messages  Controller access by RSLogix 5000 programming software  Controller access by RSLinx software for HMI or other applications You indirectly determine the number of connections the controller uses by configuring the controller to communicate with other devices in the system. The limit of connections may ultimately reside in the communication module you use for the connection. If a message path routes through a communication module, the connection related to the message also counts towards the connection limit of that communication module. The 1756-L6x controller supports 250 connections; the 1756-L7x controller supports 500. To calculate the total connections for a controller, consider the connections to local I/O modules and the connections to remote modules. Use this table to tally local connections. Connection Type Device Connections per Total Quantity Device Connections Local I/O module (always a direct connection) 1 1756-M16SE, 1756-M08SE, 1756-M03SE SERCOS motion module 3 1756-M02AE, 1756-M02AS, 1756-HYD02 analog motion module 1756-CN2, 1756-CN2R communication module 0 1756-CNB, 1756-CNBR communication module 1756-CN2RXT communication module 1756-EN2F, 1756-EN2T communication module 0 1756-ENBT, 1756-EWEB communication module 1756-EN2TXT communication module 1756-DNB communication module 2 1756-DHRIO communication module 1 1756-RIO communication module 1756-DHRIOXT communication module 1756-DH485 communication module 1 Total Regardless of how you configure local I/O modules (rack-optimized or direct connect), the controller establishes a direct connection for each local I/O module. Remote connections depend on the communication module. The number of connections the module supports determines how many connections the controller can access through that module. Use this table to tally remote connections for the controller. Publication 1756-TD001D-EN-E - May 2011 21 1756 ControlLogix Controllers Specifications Connection Type Device Connections per Total Quantity Device Connections Remote ControlNet communication module Configured as a direct (none) connection 0 or Configured as a rack-optimized connection 1 Remote I/O module over a ControlNet network (direct connection) 1 Remote Ethernet communication module Configured as a direct (none) connection 0 or Configured as a rack-optimized connection 1 Remote I/O module over an EtherNet/IP network (direct connection) 1 Remote device over a DeviceNet network 0 (accounted for in rack-optimized connection for local 1756-DNB module) Other remote communication adapter 1 Safety input module 1 Safety output module 2 Produced tag 1 Each consumer 1 Consumed tag 1 Cached message 1 Block-transfer message 1 Total 22 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications Memory Cards ControlLogix Controller Accessories Memory cards offer nonvolatile memory to permanently store a user program and tag data on a controller. The 1756-L7x ControlLogix controller comes with 1784-SD1 Secure Digital card already installed. The 1756-L6x controllers support optional CompactFlash cards that you purchase separately. The memory cards install in a socket on the controller. Through RSLogix 5000 software, you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup. The GuardLogix controller does not support user program storage or retrieval by using a CompactFlash card. Technical Specifications - 1784 Memory Cards Attribute 1784-CF64 1784-CF128 1784-SD1 1784-SD2 Memory 64 MB 128 MB 1 GB 2 GB Supported controllers 1756-L6x 1756-L7x Weight, approx. 14.2 g (0.5 oz) 1.76 g (0.062 oz) Environmental Specifications - 1784 Memory Cards Attribute 1784-CF64 1784-CF128 1784-SD1, 1784-SD2 Temperature, operating -25…70 °C (-13…158 °F) IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, storage -40…85 °C (-40…185 °F) IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity 5…95% noncondensing IEC 60068-2-30 (Test Db, Unpackaged Damp Heat) Vibration 2 g @ 10…500 Hz IEC 60068-2-6 (Test Fc, Operating) Shock, operating 30 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Shock, nonoperating 50 g IEC 60068-2-27 (Test Ea, Unpackaged Shock) Emissions Group 1, Class A CISPR 11 ESD immunity 6 kV contact discharges IEC 61000-4-2 8 kV air discharges Radiated RF immunity 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz IEC 61000-4-3 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz Publication 1756-TD001D-EN-E - May 2011 23 1756 ControlLogix Controllers Specifications Certifications - 1784 Memory Cards (1) 1784-CF64, 1784-CF128, 1784-SD1, 1784-SD2 Certification CE European Union 2004/108/EC EMC Directive, compliant with:  EN 61000-6-4; Industrial Emissions  EN 61326-1; Meas./Control/Lab., Industrial Requirements  EN 61000-6-2; Industrial Immunity  EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. 1756 Energy Storage Modules Instead of a battery, the 1756-L7x controller ships with a 1756-ESMCAP energy storage module (ESM) already installed. Technical Specifications - 1756 Energy Storage Modules Attribute 1756-ESMCAP 1756-ESMNSE 1756-ESMNRM Description Capacitor-based energy-storage ESM without WallClockTime Energy-storage module that secures module back-up power the controller by preventing the USB connection and access to SD card Comes with the controller Use this ESM if your application removal. If the SD card is installed requires that the installed ESM prior to insertion of the 1756 deplete its residual energy to ESMNRM module, the SD card 40 µJoule or less before remains functional, but not transporting it into or out of your removable. application. In this case, complete these steps before you remove the This ESM provides your application ESM. an enhanced degree of security. 1. Turn off power to the chassis. After you turn off power to the chassis, the controller’s OK status indicator transitions from Green to Solid Red to OFF. 2. Wait at least 20 minutes for the residual stored energy to decrease to 40 μJoule or less before you remove the ESM. There is no visual indication of when the 20 minutes has expired. You must track that time period. Additionally, you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only. Current draw @ 5.1V DC 330 mA 300 mA 330 mA North American temperature code T5 IEC temperature code T5 24 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications Certifications - 1756 Energy Storage Modules (1) 1784-CF64, 1784-CF128 Certification c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for US and Canada. See UL File E194810. CE European Union 2004/108/EC EMC Directive, compliant with:  EN 61326-1; Meas./Control/Lab., Industrial Requirements  EN 61000-6-2; Industrial Immunity  EN 61000-6-4; Industrial Emissions  EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions Ex European Union 94/9/EC ATEX Directive, compliant with:  EN 60079-15; Potentially Explosive Atmospheres, Protection ’n’  EN 60079-0; General Requirements  II 3 G Ex nA IIC T5 X (1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details. Publication 1756-TD001D-EN-E - May 2011 25 1756 ControlLogix Controllers Specifications 1756 ControlLogix Batteries Each ControlLogix controller ships with a battery. The 1756-L6x controllers have nonvolatile memory if you install a 1784-CF64 or 1784-CF128 industrial CompactFlash card. With nonvolatile memory, the controller can be used without a battery. If you do not use a battery, current tag data will remain in the state it was when the nonvolatile memory was saved. These tables summarize battery life, replacement battery compatibility, and recommendations for use of an externally-mounted battery assembly. Technical Specifications - 1756 ControlLogix Batteries (1) Attribute 1756-BA1 1756-BA2 1756-BATA 1756-BATM Description Lithium battery (0.59 g) Lithium battery (0.59 g) Externally-mounted Replacement lithium battery for 1756-BATM (5 g max battery assembly lithium per each D cell; contains 2 D cells) ControlLogix controllers 1756-L61, 1756-L62, 1756-L61, 1756-L62, 1756-L61, 1756-L62, 1756-BATM battery module 1756-L63 controllers, 1756-L63 controllers, 1756-L63 controllers, series A series B series A 1756-L64, 1756-L65 controllers GuardLogix controllers — 1756-L61S, 1756-L62S, — — 1756-L63S (2) (3) Supported legacy — 1756-BATM battery module 1756-L55Mx controllers 1756-L55Mx controllers controllers 1756-L60M03SE 1756-L60M03SE controller controller (1) The 1756-BATM externally-mounted battery assembly is recommended for use with all 1756-L55x, and is highly recommended for use with all series A 1756-L6x controllers, and provides longer battery life than the 1756-BA1 battery. The 1756-BATM assembly includes one 1756-BATA lithium battery assembly and a 1 m (3.28 ft) cable to connect housing to controller. (2) The 1756-L55M22, 1756-L55M23, and 1756-L55M24 controllers have nonvolatile memory and can be used without a battery. 26 Publication 1756-TD001D-EN-E - May 2011 1756 ControlLogix Controllers Specifications Serial Communication Cables The 1756-L6x controllers have a built-in serial port. 1 CD 1 CD 2 RXD 3 TXD Internal 3 TXD 2 RXD Technical Specifications - 1756 Serial Cables 4 DTR 6 DSR Jumper 5 Common 5 Common 6 DSR 4 DTR Attribute 1756-CP3 1747-CP3 7 RTS 8 CTS 8 CTS 7 RTS 9 RI 9 RI Connector type Female 9-pin D-shell To Controller To Serial Port Connector angle Right angle connector to controller, straight to serial port Length 3 m (9.84 ft) Publication 1756-TD001D-EN-E - May 2011 27 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support/, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/support/. Installation Assistance If you experience an anomaly within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada 1.440.646.3434 Outside United States or Use the Worldwide Locator at http://www.rockwellautomation.com/support/americas/phone_en.html, or contact Canada your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Outside United States Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Publication 1756-TD001D-EN-E - May 2011 Supersedes 1756-TD001C-EN-E - May 2010 Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the 1756-L61S?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products