Industrial Trading chervon right Manufacturers chervon right A chervon right ADTRAN chervon right 1150087L1
About product Specifications Datasheet FAQ

ADTRAN 1150087L1

Description

Adtran 1150087L1 Enclosure - Above ground use only; unsealed access compartments allow individual access to external wire connection terminals

Part Number

1150087L1

Price

Request Quote

Manufacturer

ADTRAN

Lead Time

Request Quote

Category

Chassis & Enclosures

Specifications

Basic

Separate customer and network unsealed access compartments allow individual access to either customer or network external wire connection terminals

Ground Use

Above ground use only

Mounting

Fast and easy mounting and wire connections allow either temporary or permanent installations

Datasheet

pdf file

Adtran 1150087L1.pdf

55 KiB

Extracted Text

Section 61150.087L1-5 C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE Issue 1, August 1996 OR DECREASE IN RELIABILITY. PRACTICES CLEI Code # DDMOJHD1 _ _ HANDLING PRECAUTIONS REQUIRED. T400 SINGLE ENVIRONMENTAL HOUSING INSTALLATION/MAINTENANCE CONTENTS 1. GENERAL............................................................... 1 2. INSTALLATION ...................................................... 1 3. REPLACEMENT PARTS ....................................... 4 4. MAINTENANCE ..................................................... 4 5. WARRANTY AND CUSTOMER SERVICE ........... 4 FIGURES Figure 1. T400 Single Environmental Housing ............ 1 Figure 2. Clearances .................................................... 2 Figure 3. Mounting Holes ............................................. 2 Figure 4. Wiring Terminals ........................................... 2 Figure 5. T400 Environmental Housing Assembly....... 3 Figure 6. Surge Arrestors and the Insertion/Extraction Tool ............................... 3 TABLES Table A. Wiring ............................................................. 3 1. GENERAL This practice provides installation and maintenance information for the ADTRAN T400 Single Environmental Housing, part number 1150087L1. Figure 1 is a view of the T400 Single Environmental Housing. Features Figure 1. T400 Single Environmental Housing The basic features of the T400 Single Environmental Housing, part number 1150087L1, include the 2. INSTALLATION following: The T400 Environmental Housing consists of a base, • Houses one of the following circuit packs: FNID, cover, O-ring, mounting bolts for the base, mounting BRIDLE-R, HTU-R, HRE, or Total Reach bracket, lag screws and spacers for the mounting • Seals the T400 circuit packs from the environment bracket. See Figures 2, 3, 4 and 5. • Allows separate, unsealed access to the customer The T400 Single Environmental and network wiring Housing is designed for above ground only mounting. Never install • Mounts above ground to a pole or wall telephone wiring during a lightning • Compact T400 Environmental Housing - 9" High x storm. 3/4 5/8 3 " Deep x 8 " Wide, 2.6 lb. with mounting bracket Install Mounting Bracket • Four replaceable gas-tube surge arrestors that 1. Clearances between the T400 Environmental provide primary lighting protection Housing and adjacent structures must be observed 61150.087L1-5A Section 61150087L1-5, Issue 1 1 WARNING! COVER TO BE REMOVED BY TELEPHONE COMPANY PERSONNEL ONLY CUSTOMER ACCESS NETWORK INTERFACE DEVICE for access during maintenance. Note clearances required for removing the Environmental Housing. See Figure 2 for mounting clearances. 2. Place the mounting bracket 3/4" spacers between the rear of the mounting bracket and the mounting surface. The spacers are required to insure the mounting bracket is not warped during installation or use. 1/2 3. Insert the 1/4" x 1 " Hex head lag screws through Mounting Holes the mounting holes of the mounting bracket and spacers. Tighten securely with a 7/16" nut driver. 3/8 5 " 9.0" 3/4" 3/16 4 " Figure 3. Mounting Holes 3. Connect the ground cable to an appropriate 8.5" ground. (Surge arrestors work only when the ground cable is connected.) 4. Replace the network cover on the base using a 7 /16" nut driver. Tighten to 20 in-lbs. 1.0" 1.0" Customer Wiring 1. Remove the customer cover on the base using a flat-head screwdriver. 6.0" 2. Connect the wiring in the terminal blocks as shown in Table A. The terminal block will accommodate a #6 Spade Lug. The terminal blocks are shown Figure 2. Clearances in Figure 4. Install the T400 Environmental Housing 3. Replace the customer cover on the base using a 1. Fasten the Environmental Housing to the mounting flat-head screwdriver. bracket using the two mounting bracket bolts. 7 2. Tighten the two bolts using a / " nut driver to 16 25 in-lbs. Power Modules in the central office should be 5 15 49 55 NC 7 13 41 47 11 removed or de-energized prior to installation and maintenance of the T400 Single Environmental Housing. Appropriate Methods and Procedures should be followed to insure WARNING! CUSTOMER ACCESS COVER TO BE REMOVED BY TELEPHONE personal safety. COMPANY PERSONNEL NETWORK INTERFACE DEVICE ONLY Network Wiring Figure 4. Wiring Terminals 1. Remove the network cover on the base using a 7 Remove the Environmental Housing Cover /16" nut driver. 2. Connect the wiring in the terminal blocks as shown 1. Wipe any debris from the cover and base. in Table A. The terminal block will accommodate 7 2. Remove the two housing cover bolts using a / " a #6 Spade Lug. 16 nut driver. 2 Section 61150087L1-5, Issue 1 61150.087L1-5A Table A. Wiring Pins ISDN BRIDLE-R ISDN TR-R HDSL HRE HDSL HTU-R HDSL FNID 5, 15 Customer NC Customer Loop 1 To Customer To Customer 7,13 Network Loop 1 NC Network Loop 1 Network Loop 1 Network 11 GND GND GND GND GND 41, 47 Network Loop 2 Network Network Loop 2 Network Loop 2 NC 49,55 NC Customer NT1 Customer Loop 2 From Customer From Customer 2. Place the cover on the base. 3. Remove the cover from the housing base. 7 3. Tighten the two bolts using a / " nut driver to 20 16 Handle the circuit packs only by the front in-lbs. panel handle. Take care to avoid the sharp exposed pins on the front and back sides of To Replace Surge Arrestors the circuit packs during installation and 1. Unseat the appropriate powering modules (located maintenance. in the central office) before replacing surge Insert the circuit pack (aligning the goldfingers on the arrestors inside the T400 single environmental circuit pack with the connector inside the environmental housing. This removes power from the wires and housing) in the wired slot. pins. Place the Cover on the Base 2. After cleaning debris from the cover and base, remove the environmental housing cover. 1. Verify that the cover assembly O-ring is properly placed around the cover and is free of debris 3. Remove the circuit pack. before replacing the cover. 4. Using the insertion/extraction tool, grasp and remove a surge arrestor (see Figure 6). Rptr. Case Cover O-ring Rptr. Base Figure 6. Surge Arrestors and the Insertion/ WARNING! Mounting Case Bolts CUSTOMER ACCESS COVER TO BE REMOVED BY TELEPHONE Extraction Tool COMPANY PERSONNEL ONLY NETWORK INTERFACE DEVICE 5. Place a replacement surge arrestor in the same position. Bracket Mounting Bolts 6. Replace the remaining surge arrestors in the same manner. Figure 5. T400 Environmental Housing 7. Reseat the powering modules at the central office. Assembly 61150.087L1-5A Section 61150087L1-5, Issue 1 3 5. WARRANTY AND CUSTOMER SERVICE 8. Perform a circuit test to verify proper circuit operation. ADTRAN will replace or repair this product within ten years from the date of shipment, if the product does not 9. Replace the cover assembly O-ring if it has not meet its published specifications or if it fails while in been replaced within the last 90 days. service. For detailed warranty, repair, and return 10. Reattach the cover on the base. information, refer to the ADTRAN Equipment Warranty and Return Policy and Procedure. Return Material Authorization (RMA) is required prior 3. REPLACEMENT PARTS to returning equipment to ADTRAN. ADTRAN does The environmental housing contains surge arrestors not recommend that repairs be performed in the field. and an O-ring which can be ordered for replacement For service, RMA requests, or further information, as follows: contact one of the following numbers: Part number: 1150083L1 4 surge arrestors and the ADTRAN Customer Service: insertion/extraction tool Applications Engineering (800) 615-1176 Part number: 3273.010 O ring (pre-sales support and inquiries) Technical Support (800) 726-8663 4. MAINTENANCE (post-sales; have unit serial number available) Sales (800) 827-0807 The T400 Single Environmental Housing requires no RMA (Repair Service) (205) 971-8722 routine maintenance to function properly. Repair and Return Address: Electrical shock can occur if surge ADTRAN, Inc. arrestor replacement is attempted Customer Service Department before removing the powering 901 Explorer Boulevard modules. Huntsville, Alabama 35806-2807 In cases where lightning is the suspected cause of circuit pack failure, ADTRAN recommends replacing all surge arrestors within the environmental housing. The surge arrestors are field replaceable as detailed in section 2. The cover assembly O-ring should be replaced if entry is gained and the O-ring has been in place for 90 days or longer. 4 Section 61150087L1-5, Issue 1 61150.087L1-5A

Frequently asked questions

How does Industrial Trading differ from its competitors?

chervon down
Industrial Trading' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

Is there a warranty for the 1150087L1?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carrier will Industrial Trading use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Can I buy parts from Industrial Trading if I am outside the USA?

chervon down
Industrial Trading will definitely serve you. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

Which payment methods does Industrial Trading accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Industrial Trading. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products